Loading...
ZBA22-0014 PUBLIC HEARING NOTICE ZBA22-0014 Dear Property Owner: A request for a Special Exception Use has been filed with the Board of Adjustment of the City of Southlake. The purpose of the hearing is to consider a request for a Special Exception Use, per Ord. No. 480, as amended, Section 44.12(1) for a Domestic Employee or Family Quarters on property described as Lot 3R, H. Granberry No. 581 Addition, an addition to the City of Southlake, Tarrant County, Texas, and located at 410 S. White Chapel Blvd. Southlake, Tarrant County, Texas. Current Zoning: “SF-1A” – Single Family Residential District. The purpose of this request is to seek approval of a Special Exception Use, more particularly a Domestic Employee or Family Quarters, often referred to as an “accessory dwelling”. If you wish to register your views on the matter, you may complete and send the enclosed Notification Response Form to the Planning & Development Services Department. You are encouraged to follow the requested action through final approval because changes are often made during the review process. Please note that this letter and its attachments constitute written notice about the proposed Variance. Please contact the Planning and Development Services Department if you have any questions: Project Contact: Reagan Rothenberger, E-mail: rrothenberger@ci.southlake.tx.us, Phone: (817) 748-8602. Dept. Phone: (817) 748-8621 CITY OF SOUTHLAKE PLANNING & DEVELOPMENT SERVICES 1400 Main St.; Suite 310 Southlake, TX 76092 Phone: (817) 748-8621 Fax: (817) 748-8077 www.cityofsouthlake.com Board of Adjustment Thursday, September 29, 2022 6:30 PM Town Hall Council Chambers 1400 Main Street Southlake, Texas Notification Response Form ZBA22-0014 Special Exception Use for 410 S. White Chapel Blvd. Meeting Date: September 29, 2022 at 6:30 PM Fill out: Owner: _____________________________ Address: ____________________________ City, State, Zip Code: __________________ PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed Variance referenced above. Space for comments regarding your position: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Signature: _______________________________________ Date: ______ Additional Signature: _______________________________ Date: ______ Printed Name(s): _____________________________________________ Must be property owner(s) whose name(s) are printed at top. Otherwise contact the Planning Department. One form per property. Phone Number (optional): ______________________________________ Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone: (817)748-8621 Fax: (817)748-8077 E-mail: rrothenberger@ci.southlake.tx.us 1256 MAIN STREET SOUTHLAKE, TEXAS 76092 SUITE 226 817.882.8882 WWW.FWARCHITECTS.COM FORT WORTH, TEXAS 76116 2920 ALTA MERE DRIVE A-3MADAN RESIDENCEISSUE DATE : 9/2/22 SHEET NUMBER ( SHEET 3 OF 19 ) REVISIONS NO.DATE DESCRIPTION 410 S. WHITE CHAPEL BLVD.SOUTHLAKE, TEXAS, 76034TARRANT COUNTYc Copyright, F+W ARCHITECTS, LLC 2022by the builder or the person in authority of this project. Any discrepancy, error,These plans are intended to provide the basic construction information necessaryto substantially complete this structure. These plans must be verified and checkedand Local codes, ordinances, and restrictions take precedence over any part ofdesigner before any construction is commenced or purchases made. It is recommendedand / or omission, if found, is to be brought to the immediate attention of thethat the owner or builder obtain complete Engineering services; Foundation, Hvac, andStructural, before beginning construction of any kind. Note: All Federal, State,by any means without the expressed written consent of Flynn+Watson. All rights reservedFlynn+Watson Architects and are not to be used for construction, reused, traced, or reproducedthese plans which may conflict with same, and must be strictly obeyed and followedbefore and during construction. These plans, and their use are the property ofREFPOOL 37'-10" x 17'-9" SPA 11'-2" x 9'-10" R1 R1 R1 R1 R2 R2 R2 R2 40'-0"15'-0"65'-0"244'-2"106'-1"43'-8"22'-7"141'-31/2"22'-101/2"155'-6"25'-3"170'-9"106'-1"70'-0"9'-4"60'-0"66'-91/2"120'-0" 12'-6" 20'-3"27'-10" 4'-0" 15'-8"18'-8"3'-5"1'-4"26'-2"1'-4"19'-61/2"16'-0" 6'-0" 20'-0" 22'-101/2" 20'-0"40'-0"206'-11/2"207'-61/2"28'-41/2"37'-111/2"45'-1"38'-4"11'-11"5'-8"39'-5"80'-101/2"39'-5"31'-8"FFE. 640' FFE. 639.67' FFE. 637.67' FFE. 637.67' FFE. 635.67' FFE. 638' FFE. 639.67' 65'-0" DRAINAGE EASEMENT 40''-0" BUILDING SET BACK LIMITS OF 100 YEAR FLOOD PLAIN ( AQUA TERRA CAB A SL. 12418 ) 5'-0" RETAINING WALL 6'-0" RETAINING WALL METAL GUARD RAIL PER LANSCAPE CONTRACT METAL GUARD RAIL PER LANSCAPE CONTRACT MECHANICAL EQUIPMENT MECHANICAL EQUIPMENT FIRE PIT FINAL LOCATION TO BE VERIFIED WITH BUILDER AND HOMEOWNER MECHANICAL EQUIPMENT METAL GUARD RAIL PER LANSCAPE CONTRACT DOWN DOWN DOWNDOWNDOWN 10'-0" EASEMENT 15'-0" SET BACK 3º W. I. GATE 3º W. I. GATE WROUGHT IRON AUTO GATE 5'-0" HIGH WALL W/ STUCCO FINISH WROUGHT IRON AUTO GATE 5'-0" HIGH WALL W/ STUCCO FINISH NOTE: REFER TO CIVIL GRADING PLANS FOR PROPOSED GRADING AND DRAINAGE INFORMATION. NOTE: REFER TO LANDSCAPE ARCHITECT'S PLANS FOR PROPOSED LANDSCAPE WALLS & PAVING INFORMATION. LANDSCAPE ARCHITECT TO PROVIDE TREE SURVEY INFORMATION SWENLOT 3R, H. GRANBERRY NO. 581 ADDITION CITY OF SOUTHLAKE, TEXAS ZONING LEGAL DESCRIPTION 410 S WHITE CHAPEL BLVD. SF 1AN 89º 16' 23" W 483.00'N 88º 43' 18" E 557.83'N 00º 24' 35" E 208.99' S 19º 48' 375" W 157.72' R= 573.00' A= 58.89' Ç WHITE CHAPEL BLVD. 650 651 649 647 648 646 645 644 643 642 640 641 639 638 637 636 635 634 633 632 631 630 629 628 627 626 625624623 624 625 626 627 PUTTING GREEN LOWER PATIO AREA TENNIS COURT POOL EQUIP. EXISTING TREE TO REMAIN EXISTING TREE TO BE REMOVED NOTE: TOPO PROVIDED BY GATEWAY ENGINEERING SURVEY PROJECT # 16-051 2 CAR GARGAGE PORT COCHERE ENTRY PORCH PROPOSED 2 STORY RESIDENCE OUTDOOR LIVING BY OTHERS COVERED PATIO COVERED PATIO POOL DECK GUEST HOUSE MECHANICAL EQUIPMENT CONCRETE DRIVE CONCRETE DRIVE & PARKING CONCRETE DRIVE LANDSCAPE PLANTER CONCRETE DRIVE & MOTOR COURT CONCRETE PARKING CONCRETE PARKING SURFACE FLOW BUILDING SETBACK BUILDING SETBACKBULDING SETBACKBUILDING SIDE YARD GENERAL SITE PLAN NOTES 1.0 BUILDER TO RESCULPTURE TOPO/FINISH GRADE TO PROVIDE PROPER DRAINAGE OF SURFACE WATER AWAY FROM BUILDING AS REQ'D. 2.0 FINAL LOCATION OF PROPOSED RESIDENCE TO BE DETERMINED BY BUILDER. 3.0 EXPOSED FOUNDATION TO BE MINIMUM OF 0" AND A MAXIMUM OF 24" ABOVE FINISHED GRADE OR PER SUBDIVISION REQUIREMENTS. UNDERPIN ALL EXPOSED FOUNDATIONS. 4.0 THERE ARE NO STORM SEWER INLETS WITHIN THE LOT FRONTAGE OR 101-0" BEYOND NE SIDE PROPERTY LINES. 5.0 UTILITY LINE LOCATIONS ARE APPROXIMATES- GENERAL CONTRACTOR TO FIELD VERIFY FOR EXACT LOCATIONS. 6.0 VERIFY METER AND UTILITY SERVICE LOCATIONS PRIOR TO INSTALLATION. 7.0 EROSION CONTROL BARRIERS TO BE INSTALLED PRIOR TO COMMENCEMENT OF CONSTRUCTION. 8.0 STABILIZED TEMPORARY CONSTRUCTION DRIvELUAY TO BE IN PLACE PRIOR TO COMMENCEMENT OF CONSTRUCTION. 9.0 CONFIRM ALL DRIVEWAY, WALKWAY AND PVC LAYOUTS/ LOCATIONS PRIOR TO COMMENCING WORK. 10.0 PROVIDE CONTROL AND EXPANSION JOINTS AS REQUIRED ON CONCRETE DRIVES, WALKS AND PATIOS. 11.0 ALL EXTERIOR HvAC EQUIPMENT TO BE SCREENED PER CITY REQUIREMENTS, DEED RESTRICTIONS OF SUBDIVISION OR NEIGH5ORHOOD ASSOCIATION. 12.0 GARBAGE RECEPTACLES TO BE STORED IN GARAGE OR SCREENED FROM VIEW AND ANIMAL ACCESS. 13.0 LOCATION OF MAILBOX AND EXTERIOR DRIvELUAY LI6HT(5) TO BE VERIFIED PRIOR TO INSTALLATION. 14.0 ALL CONSTRUCTION MATERIALS AND WASTE TO BE STORED ON SITE DURING CONSTRUCTION. 15.0 LANDSCAPE PLANS TO BE PROVIDED BY OTHERS AND PERMIT FOR SAME TO BE OBTAINED SEPARATELY FROM NESE PLANS. 16.0 NO EXISTING TREES TO BE REMOVED OR DISTURBED WITHOUT OWNER APPROVAL. 17.0 ALL STUMPS AND ROOTS SHALL BE REMOVED FROM NE SOIL TO A DEPTH OF 12" BELOW NE SURFACE OF NE GROUND IN NE AREA OF NE BUILDING. 18.0 CONTRACTOR SHALL CLEAN UP AREAS AFFECTED BY DAILY WORK AND REMOVE DEBRIS AND MATERIALS FROM NE SITE UPON COMPLETION OF NE WORK. GENERAL PROJECT NOTES 1.0 THESE CONSTRUCTION DOCUMENTS ARE INTENDED TO MEET ALL APPLICABLE CODES AND ORDINANCES. CONTRACTOR TO COMPLY WITH ALL LOCAL CODES, ORDINANCES AND DEED RESTRICTIONS. CONTRACTOR SHALL ALSO REQUIRE ALL SUBCONTRACTORS TO COMPLY WITH THESE REGULATIONS. 2.0 ANY DISCREPANCIES IN CONSTRUCTION DOCUMENTS OR NONCOMPLIANCE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO ANY WORK BEING PERFORMED OR MATERIALS BEING ORDERED. 3.0 BUILDER ACCEPTS FULL RESPONSIBILITY FOR CHECKING PLANS TO ASSURE CONFORMITY TO CURRENT LOCAL BUILDING CODES. SHOULD ANY CHANGES BE MADE TO THESE PLANS BY BUILDER OR H15 REPRESENTATIVES WIT(-LOUT CONTACTING THE ARCHITECT, THE BUILDER WILL ACCEPT FULL LIABILITY FOR AMENDED PLANS. 4.0 ARCHITECTS ARE GOVERNED BY THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS, (512)45S-1363. 5.0 WHILE TI-IESE DRAWINGS ARE INTENDED TO SHOW SAME, THE ARCHITECT IS NOT RESPONSIBLE FOR GOVERNING AUTHORITY INTERPRETATIONS WHERE THOSE INTERPRETATIONS CONFLICT WITH THESE DRAWINGS 4/OR SPECS. 6.0 PORTIONS OF THI5 WORK MAY NOT HAVE SEEN DRAWN BY A REGISTERED ARCHITECT. 7.0 THESE DRAWINGS/SPECS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT IS EXECUTED OR NOT. THESE DRAWINGS SHALL NOT BE USED BY THE CLIENT FOR OTHER PROJECTS, FOR ADDITIONS TO THIS PROJECT, OR FOR COMPLETION OF TI-115 PROJECT BY OTHERS WITHOUT PERMISSION OF THIS ARCHITECT. 8.0 THESE DOCUMENTS DO NOT SHOW TYPICAL DETAILING 4/OR WATERPROOFING. 9.0 THESE DOCUMENTS DO NOT SPECIFY ACTUAL PRODUCTS OR MATERIAL SELECTIONS. CONTRACTOR ACCEPTS FULL RESPONSIBILITY FOR APPROPRIATE AND PROPER DETAILING FOR AND BETWEEN ALL ACTUAL PRODUCTS/MATERIALS SELECTED WHEN INSTALLED. 10.0 ALL COMPONENTS, MATERIALS, ASSEMBLIES AND FINISHES TO BE CONSTRUCTED AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS, CODE REQUIREMENTS AND REGULATED BUILDING PRACTICES. 11.0 ARCHITECT IS NOT RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION WHICH ARE NOT DETAILED IN TI-IESE CONSTRUCTION DOCUMENTS. CONTRACTOR WILL BE RESPONSIBLE FOR ALL ASPECTS OF CONSTRUCTION INCLUDING BUT NOT LIMITED TO ALL WATER AND DAMP PROOFING, LOAD CONNECTIONS AND MECHANIC, ELECTRICAL AND PLUMBING SYSTEMS. 12.0 ALL MATERIALS AND LABOR TO BE GUARANTEED FOR ONE YEAR FROM THE DATE OF FINAL PAYMENT, IN ADDITION TO ALL WARRANTIES TI-IAT ARE STANDARD TO THE INDUSTRY. CONTRACTOR TO PROVIDE (SUPPLY AND INSTALL) ALL EQUIPMENT, LABOR SERVICES, AND MATERIALS REQUIRED FOR THE COMPLETE APPROVED INSTALLATION OF THE SYSTEMS CALLED FOR. 13.0 THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THE CONTRACTOR IS RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS NECESSARY FOR COMPLETION OF WORK 14.0 ALL DIMENSIONS TO BE VERIFIED IN THE FIELD. REPORT ANY AND ALL DISCREPANCIES, ERRORS OR OMISSIONS TO THE ARCHITECT PRIOR TO COMMENCING WORK AND/OR ORDERING MATERIALS. MINOR DEVIATIONS, SUBJECT TO CONSTRUCTION REQUIREMENTS AND FIELD CONDITIONS, CAN BE EXPECTED. 15.0 UNDER NO CIRCUMSTANCES SHALL ANY DIMENSION BE SCALED FROM THESE DRAWINGS. ANY CRUCIAL DIMENSION NOT GIVEN SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 16.0 ALL DIMENSIONS SHOWN ON PLAN ARE TO THE STRUCTURAL FACE OF WALL AND DO NOT INCLUDE WALL FINISHES OR FURRING. 17.0 THE CONTRACTOR SHALL GIVE NOTICE TO ALL AUTHORIZED INSPECTORS, SUPERINTENDENTS OR PERSONS IN CHARGE OF UTILITIES AFFECTED BY HIS OPERATIONS PRIOR TO COMMENCING WORK. 18.0 THE CONTRACTOR 15 TO FILE FOR, AND SECURE ALL APPROVALS, PERMITS, TESTS, INSPECTIONS AND CERTIFICATES OF COMPLIANCE AS REQUIRED. THE CONTRACTOR IS RESPONSIBLE FOR ASSURING THAT ALL PERMITS NECESSARY TO LEGALLY PERFORM THE WORK HAVE SEEN OBTAINED PRIOR TO COMMENCING CONSTRUCTION. 19.0 VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION START. 20.0 IN CASE OF DISCREPANCIES OR CONFLICTS ON THE DRAWINGS AND SPECIFICATIONS, OR BETWEEN THE DRAWINGS AND THE EXISTING CONDITIONS, CONTACT THE ARCHITECT OR OWNER BEFORE PROCEEDING WITH THE WORK. 21.0 CONTRACTOR SHALL CLEAN UP CONSTRUCTION AREAS AFFECTED BY DAILY WORK AND MAINTAIN A CLEAN AND ORDERLY WORK AREA AT ALL TIMES. REMOVE MATERIALS TO APPROVED DUMP SITES ONLY. THE CITY OF SOUTHLAKE HAS ADOPTED THE CODE EDITIONS BELOW : THE 2018 INTERNATIONAL BUILDING CODE & AMENDMENTS THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE& AMENDMENTS THE 2018 INTERNATIONAL FUEL GAS CODE & AMENDMENTS THE 2018 INTERNATIONAL MECHANICAL CODE & AMENDMENTS THE 2018 INTERNATIONAL RESIDENTIAL CODE & AMENDMENTS THE 2018 INTERNATIONAL PLUMBING CODE & AMENDMENTS THE 2018 INTERNATIONAL FIRE CODE & AMENDMENTS THE 2020 NATIONAL ELECTRIC CODE WITH REGIONAL AMENDMENTS. CITY CODE REQUIREMENTS IMPERVIOUS AREAS DRIVEWAY AREA HARD SURFACE AREA LIVING AREA GUEST HOUSE LIVING AREA MAIN A/C MASTER PATIO AREA OUTDOOR LIVING AREA PATIO AREA 2 9,661.05 2,506.13 486.11 6,994.13 205.11 1,220.24 198.68 21,271.45 ft² LOT COVERAGE LOT AREA 107,206.44 SCALE: 1" = 20' 1 SITE PLAN A-3 IMPERVIOUS COVERAGE PERCENTAGE = 19.8% TOTAL BUILDING COVERAGE PERCENTAGE = 6.5% R-2 9-1-22 244' HOUSE SET BACK R-1 8-30-22 SET BACKS ADDED 1256 MAIN STREET SOUTHLAKE, TEXAS 76092 SUITE 226 817.882.8882 WWW.FWARCHITECTS.COM FORT WORTH, TEXAS 76116 2920 ALTA MERE DRIVE A-19MADAN RESIDENCEISSUE DATE : 5/19/22 SHEET NUMBER ( SHEET 19 OF 19 ) REVISIONS NO.DATE DESCRIPTION 410 S. WHITE CHAPEL BLVD.SOUTHLAKE, TEXAS, 76034TARRANT COUNTYc Copyright, F+W ARCHITECTS, LLC 2022by the builder or the person in authority of this project. Any discrepancy, error,These plans are intended to provide the basic construction information necessaryto substantially complete this structure. These plans must be verified and checkedand Local codes, ordinances, and restrictions take precedence over any part ofdesigner before any construction is commenced or purchases made. It is recommendedand / or omission, if found, is to be brought to the immediate attention of thethat the owner or builder obtain complete Engineering services; Foundation, Hvac, andStructural, before beginning construction of any kind. Note: All Federal, State,by any means without the expressed written consent of Flynn+Watson. All rights reservedFlynn+Watson Architects and are not to be used for construction, reused, traced, or reproducedthese plans which may conflict with same, and must be strictly obeyed and followedbefore and during construction. These plans, and their use are the property ofREFWG16'-0" x 10'-0"Sill 0"WG45'-0" x 7'-0"Sill 1'-0"1193'-0"x8'-0"WG3 2'-0" x 6'-0" Sill 2'-0"WG24'-0" x 4'-0"Sill 4'-0"2'-8"x8'-0"2'-4"x8'-0"2'-6"x8'-0" 2'-8"x8'-0" GUEST BATH GUEST LIVING GUEST BEDROOM GUEST KITCHEN 20'-3" 11'-7"2'-7"6'-1"22'-7"11'-6"11'-01/2"4'-61/2"4'-7"7'-81/2"5'-9"14'-6"4'-0"4'-01/2"5'-11/2"17'-51/2"5'-11/2"6'-5"3'-31/2"7'-9"FURR DOWN WC LAV 1 :12 SLOPED CEILING FROM 10' TO 11'-5"LINE OF ROOF OVERHANGLINE OF ROOF OVERHANGLINE OF ROOF OVERHANG W/DR/S9' CEILING 36"x60" SHOWER LINE OF ROOF OVERHANG 1 :12 SLOPED CEILING FROM 10' TO 11'-5" SINK FLR CARPET FLR: TILE FLR: TILE FLR: TILE22'-7"81/2"6'-21/2"20'-3"3'-0"8'-01/2"5'-2"51/2" 3 A-8 3 A-8 RECESS SLAB 4" CONTRACTOR TO VERIFY WC LAV4" 2'-4"2'-4"2'-4"6'-0"10'-0" PL. HT. @ GUEST HOUSE FLOOR11'-8" PL. HT. @ GUEST HOUSE FLOORMETAL ROOF ING 1 :12 PITCH ±0" 1 MAIN FLOOR ±0" 1 MAIN FLOOR +12' 2 MAIN PLATE +12' 2 MAIN PLATE +13'-6" 3 UPPER FLOOR +13'-6" 3 UPPER FLOOR 2'-0"3'-6"4'-6"8"10'-0"11'-8"METAL RAIL STUCCO EXTERIOR ON FRAMING STUCCO FASCIA & SOFFIT WINDOW BOX 2x8 TUBE STL. LOUVERS WG2 DRIP EDGE ±0" 1 MAIN FLOOR ±0" 1 MAIN FLOOR +12' 2 MAIN PLATE +12' 2 MAIN PLATE +13'-6" 3 UPPER FLOOR +13'-6" 3 UPPER FLOOR 10'-0"10'-0"11'-8" TOP PLATE3'-41/2"METAL RAIL STUCCO FASCIA & SOFFIT WG4 119 WG1 STUCCO FASCIA & SOFFIT STUCCO EXTERIOR ON FRAMING 2x8 TUBE STL. LOUVERS STUCCO ON CMU STUCCO SOFFITREFGUEST BATH GUEST LIVING GUEST BEDROOM GUEST KITCHEN CTW/DR/SWPS CTGFICT S S SS SSS PANEL SSTWP WPCA7 220v 220v WP CTCA7±0" 1 MAIN FLOOR ±0" 1 MAIN FLOOR +12' 2 MAIN PLATE +12' 2 MAIN PLATE +13'-6" 3 UPPER FLOOR +13'-6" 3 UPPER FLOOR METAL RAIL STUCCO ON CMU STUCCO EXTERIOR ON FRAMING STUCCO FASCIA & SOFFIT WG2 2x8 TUBE STL. LOUVERS ±0" 1 MAIN FLOOR +12' 2 MAIN PLATE +13'-6" 3 UPPER FLOOR 10'-0" TOP PLATE3'-6"5'-2"1'-4"STUCCO EXTERIOR ON FRAMING METAL ROOFING WG2 STUCCO ON CMU STUCCO FASCIA & SOFFIT SCALE: 3/16" = 1'-0" 1 GUEST HOUSE FLOOR PLAN A-19 SCALE: 3/16" = 1'-0" 2 GUEST HOUSE FORMSET A-19 SCALE: 3/16" = 1'-0" 3 GUEST HOUSE ROOF PLAN A-19 SCALE: 3/16" = 1'-0" 6 RIGHT SIDE GUEST HOUSE ELEVATION A-19 SCALE: 3/16" = 1'-0" 5 GUEST HOUSE FRONT ELEVATION A-19 SCALE: 3/16" = 1'-0" 4 GUEST HOUSE ELECTRICAL PLAN A-19 SCALE: 3/16" = 1'-0" 7 LEFT SIDE GUEST HOUSE ELEVATION A-19 SCALE: 3/16" = 1'-0" 8 REAR GUEST HOUSE ELEVATION A-19 1256 MAIN STREET SOUTHLAKE, TEXAS 76092 SUITE 226 817.882.8882 WWW.FWARCHITECTS.COM FORT WORTH, TEXAS 76116 2920 ALTA MERE DRIVE A-2MADAN RESIDENCEISSUE DATE : 5/19/22 SHEET NUMBER ( SHEET 2 OF 19 ) REVISIONS NO.DATE DESCRIPTION 410 S. WHITE CHAPEL BLVD.SOUTHLAKE, TEXAS, 76034TARRANT COUNTYc Copyright, F+W ARCHITECTS, LLC 2022by the builder or the person in authority of this project. Any discrepancy, error,These plans are intended to provide the basic construction information necessaryto substantially complete this structure. These plans must be verified and checkedand Local codes, ordinances, and restrictions take precedence over any part ofdesigner before any construction is commenced or purchases made. It is recommendedand / or omission, if found, is to be brought to the immediate attention of thethat the owner or builder obtain complete Engineering services; Foundation, Hvac, andStructural, before beginning construction of any kind. Note: All Federal, State,by any means without the expressed written consent of Flynn+Watson. All rights reservedFlynn+Watson Architects and are not to be used for construction, reused, traced, or reproducedthese plans which may conflict with same, and must be strictly obeyed and followedbefore and during construction. These plans, and their use are the property ofARTISTIC IMAGE RENDERINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES. SEE CONSTRUCTION DRAWINGS FOR FINAL BUILDING DESIGN INFORMATION FRONT ELEVATION FRONT ELEVATION FRONT ELEVATION RIGHT FRONT ELEVATION RIGHT ELEVATION REAR ELEVATION LEFT REAR ELEVATION LEFT ELEVATION REAR YARD /GUEST ELEVATION REAR YARD REAR YARD STREET VIEW