Loading...
Item 9A - PlansIKONK:S +SEPHORA 10423 3001 State Hwy 114 Southlake, TX 76092 i AGI Date Created: 09-02-2021 Date Revised: 01-27-2022 IKOHR:s + S E P H O R A SITE PLAN � ,� � •,� .. :.D.. ,� � !� - - 4ft It B- � • ■ �� � � , |■ % 4k . ,41L VIL . ' Pm %* ' ® - - - � � , - . ■ � . . ' • ` � � ' - . Ir ' kip „ � _■ _ / , � � � ■. � � � �- - - _ - � � AGI P.2 IKOHR:s +SEPHORA SIGN INVENTORY Sign Existing Action Dimensions Proposed Qty Sq Ft E01 Kohl's Letterset Leave As Is 60.875" x 466" NSA 1 197.00 E02 Tenant Panel Remove & Replace 32" x 145.25" Install new Kohl's & Sephora Routed aluminum panel with backed acrylic 2 52.00 E03 Tenant Panel Remove &Replace South: 17.75"x115" East: 17.75"x115" North: 18.75"x115" West: 18.25"x115" Install new Kohl's & Sephora Lexan Panel Install new Kohl's & Sephora Lexan Panel Install new Kohl's & Sephora Lexan Panel Install new Kohl's & Sephora Lexan Panel 1 1 1 1 57.90 E04 Tenant Panel Remove & Replace 21.5" x 128" Install new Kohl's & Sephora Lexan Panel 2 38.22 E05 Tenant Panel Remove & Replace 20.625" x 124.25" Install new Kohl's & Sephora Lexan Panel 2 35.6 E06 Tenant Panel Remove & Replace 20.625" x 124" Install new Kohl's & Sephora Lexan Panel 2 35.52 E07 Kohl's Letterset Leave As Is 60.875" x 466" NSA 1 197.00 E08 Kohl's Letterset Leave As Is 60.875" x 466" NSA 1 197.00 SIGN VARIANCE SIGN: EXISTING SQ FT: 810.24 N01 CABINET SIGN Install New 31.875" x 180" Install new Sephora Push-Thru Letterset 1 39.84 TOTAL SQ FT: 850.08 P. 3 IKOHR:s + SEPHORA 0 m SIGN VARIANCE SIGN: CABINET SIGN 15'-0" 12'-1 1 /4" (V.O.) 8'-5 13/16" 1 10 KOHR:l r N> N +SEPHORA SEPH-REFACE SCALE:1 /2"=1'-0" SCALE:3/8"=1'-0" SIGN INVENTORY i A131 9'-7" 4 10'-8" (RETAINER SIZE) (RETAINER SIZE) 1 oo KON &:S +SEPHORA go> K N&.S+SEPHORA SCALE:3/8"=1'-0" rT = (MSEPH-REFACE (SOUTH) i(OSEPH-REFACE SCALE: 3/8"=1'-0" 9'-7" (RETAINER SIZE) 10'-4 1/4" $'-s" ► (RETAINER SIZE) K�NL;S+SEPHORACo Lu 9'-61/4" ► SSCAL-� E:3/8"=1'-0" 00 +SEPHORA o (MSEPH-REFACE (NORTH) 9'-7" SEPH-REFACE SCALE:3/8"=1'-0" (RETAINER SIZE) 10'-4" _ KO (RETAINER SIZE) i w N MGLL� +SEPHORA 9'-6" u,co> 2 p SCALE:3/8"=1'-0" r - w SEPH-REFACE (EAST) KQ N Z: S+ S E P H O R A r-I = 9'-7" I SEPH -REFACE SCALE: 3/8"=1'-0" (RETAINER SIZE) w u - CDoLL> C,co> KONL:S+SEPHORA Go ��Ir- c SCALE:3/8"=1'-0" MSEPH-REFACE (WEST) ml IKOHR:s + SEPHORA ELEVATION i AGI P.5 IKOHR:s +SEPHORA E01 - CHANNEL LETTER EXISTING Channel Letters Leave as is. Sign is 60.875" X 466", Neon illuminated i AGI IKOHR:s Sign Variance Request 1 + S E P H O RA N01 -HANGING CABINET SIGN AGI EXISTING 15'-0" m 11'-11 15/ I ti N FRONT ELEVATION SCALE:3/8"=V-0" 3" SIDE VIEW PROPOSED HANGING CABINET SIGN Install new Sephora hanging cabinet sign centered under archway & connect to primary power. Fagade able to accept sign and primary power to be provided by others, P.7 IKOHR:s +SEPHORA HANGING SIGN For reference only, cut sheet in design. 0 m 00 ti ti LA CUT SHEET 15'-0" Sign Variance Request FRONT ELEVATION VERTICAL MATERIAL SEAM IN FACE; SEAM CAN BE FILLED ' AND SANDED SMOOTH PRIOR TO PAINTING. COSTS TO DO SO WOULD BE REFLECTED IN PRICING SHOULD THIS OPTION BE CHOSEN. NOTE: SIZES OVER 25 FT LONG WILL HAVE AN UNFILLABLE SEAM NIGHT VIEW E:3/8"=1'-0" 3" SIDE VIEW >H-THRU DETAIL kLE: N.T.S. i AGI IKOHR:s Not part of this sign variance request. Shown for context only. 1 + S E P H O RA E02 - SEPH-REFACE AGI EXISTING IKO IMES f + SE PHO RA :F4::. PROPOSED 12'-1 1 /4" (V.O.) 8'-5 13116" '� T^ (D I o Ir-; KOHEI N> N V +SEPHORA FRONT VIEW SCALE:1 /2"=Vm0" SEPH-REFACE Please remove and replace existing Kohl's tenant panel with routed aluminum panel with backed black acrylic, panel to be painted to match SW 6500 white. P.10 IKOHR:s Not part of this sign variance request. Shown for context only. , + S E P H O RA E03 - SEPH-REFACE AGI L4 EXISTING PROPOSED KONLS'sE PHORA�- -` v, 9'-7" (RETAINER SIZE) ,rp K�1"11:S+SEPHORA FRONT VIEW - SOUTH QTY SCALE:3/8"=1'-0" 9'-7" (RETAINER SIZE) LU LU LL t0�O> N �O S + (D� s SE PHOR FRONT VIEW - NORTH QTY 1 SCALE:3/8"=1'-0" 9'-7" I� (RETAINER SIZE) 8'-9" I KQNL;S+SEPHOR FRONT VIEW - EAST SCALE:3/8"=1'-0" - 9'-7" (RETAINER SIZE) 8'-9" QTY 1 - W �J W N �OH �� .eo> +SEPHOR) �. o 00 FRONT VIEW - WEST QT` SCALE:3/8"=1'-0" SEPH-REFACE Please remove and replace existing Kohl's tenant panel with lexan face, with digitally printed vinyl to match 6500 white vinyl and copy to match SW Caviar. *Note: Back side of sign (North face) top retainer is broken.* P.11 IKOHR:s +SEPHORA Not part of this sign variance request. Shown for context only. E04 - SEPH-REFACE 4 � � PROPOSED 10'-8" (RETAINER SIZE) 9'-10, LU a N J w M20�>a7KOHR:S+SEPHOR o "� 9 � x J FRONT VIEW QTY 2 SCALE:3/8"=1'-0" SEPH-REFACE i AGI Please remove and replace existing Kohl's tenant panel with lexan face, with digitally printed vinyl to match 6500 white vinyl and copy to match SW Caviar. P.12 IKOHES + SEPHORA EXISTING Not part of this sign variance request. Shown for context only. E05 - SEPH-REFACE 10'-4 1 /4" ► (RETAINER SIZE) 9'-6 1 /4" 00 W _ L'go KONZ:S+SEPHORA o FRONT VIEW SCALE:3/8"=V-0" i AGI SEPH-REFACE Please remove and replace existing Kohl's tenant panel with lexan face, with digitally printed vinyl to match 6500 white vinyl and copy to match SW Caviar. P.13 IKOHR:s +SEPHORA I-t/ a in EXISTING Not part of this sign variance request. Shown for context only. PROPOSED E06 - SEPH-REFACE 10'-4" (RETAINER SIZE) 9'-6" \ J W a"2� ICON L:S + S E P H 0 R D0>� 00 � s FRONT VIEW SCALE:3/8"=V-0" • SEPH-REFACE i AGI Please remove and replace existing Kohl's tenant panel with lexan face, with digitally printed vinyl to match 6500 white vinyl and copy to match SW Caviar. P.14 IKOHR:s Not part of this sign variance request. Shown for context only. , + S E P H O RA E07 - CHANNEL LETTER AGI x lllrrl! �If11r� rr�+rr EXISTING Channel Letters Leave as is. Sign is 60.875" X 466", Neon illuminated P.15 IKOHR:s + SEPHORA Not part of this sign variance request. Shown for context only. E08 - CHANNEL LETTER !-1W} i EXISTING Channel Letters Leave as is. Sign is 60.875" X 466", Neon illuminated i AGI P.16 Typical Signage Comments NOTES FOR ALL BUILDING SIGNS: • Center sign vertically in sign band (between awning brackets below & decorative brick pattern above) and horizontally over window storefront/wall bay/architectural elements (or lease lines, very dependent on building/architecture). • Sign is to be no more than 75% (between 70-80%) of total width of premises, max. • No visible electrical equipment or structural elements allowed, including but not limited to: conduit, transformers, wiring, angles, bolts, brackets, angle iron, Unistrut, etc. (incl. on roof or rear of parapet) • Core drilling is to be from the exterior to the interior to prevent spalling • Utilize existing penetrations where possible • Minimize number and size of penetrations in wall • Seal all, old and new, penetrations in walls and paint to match • Utilize and conceal non -corrosive mounting hardware/fasteners • Any stickers, U.L labels, etc. are not to be visible from ground, if not possible, sticker(s) color shall match sign • Tenant is responsible for removing signage, cleaning facade, and patching all penetrations to match existing facade/mortar/brick colors, texture(s), materials, conditions, etc. to like -new condition. • When patching/repairing facade, Tenant is responsible for painting seam to seam, to keep facade colors consistent and in a first-class state. • Tenant may be required to remove and replace signage if not installed per LL's approval • Tenant to provide adequate blocking behind any EIFS to provide structural stability for all signage and exterior modifications • Any disconnect switch to be a part of signage, letters or wireway(if applicable). If not possible, shall be in a concealed location as possible • Remove all existing j-boxes, conduit, goose -neck lights, etc. remaining from previous tenant • Signage to be installed within forty five (45) days of receiving LL approval. • Halo lit standoffs to be painted to match building color and to be no more than 2", electrical wiring to be in conduit (not exposed to the elements) • All window lettering to be raised applied (1/4" min. FCO), apply vinyl to interior glass face to mirror letters and hide adhesive • Mount below roof deck (preferred), if not possible, do not penetrate roof membrane/flashing and seal penetrations on both sides o Utilize LL required roofer to seal electrical service penetration/s (via pitch pan/weatherhead) o Wiring to be in conduit and organized in a clean manner o Paint all to match parapet color Minimum Letter Requirements • Letters to be individual 5" (no larger) deep aluminum channel letters/logo (reverse halo lit is acceptable at 3" with no more than 2" offsets) Typical Signage Comments • <24" channel letters/logos aluminum .040 sides & .063 backs (fronts when halo lit) • <24" to have 1/8" thick acrylic faces(s) min. • > or = 24" channel letters/logos aluminum .063 sides & .090 backs (fronts when halo lit) • > or = 24" to have 3/16" thick acrylic face(s) min. • White letter faces with black returns (this may be for a specific property(ies), like Sugarland or one in AZ) • Logo to be 5" deep, Letters to be 3" deep with 2" wireway behind backerplate (this is similar to the approved ATT signage at The Brickyard) • For halo lit sign, channel letters to be 3" thick/deep and offset 1-2" from building face • Sign/s shall be flush mounted (per lease) or include a backer plate to conceal a 2" deep wireway, please revise and resubmit meeting one of these 2 criterium. Wireways with Backerplates (Cloud) Requirements • LL recommends mounting letters to a backer plate to minimize number of penetrations in fagade. • Channel letters to be mounted to a 1/8" thick min. aluminum backer plate (cloud), which is not to extend more than 3" (max.) from letters on any side. Submit color of backerplate to LL for final approval. • Mount letters and backerplate to a 2" max. x 12" (height dimension is flexible) wireway (raceway) and is not to be visible. • Hold wireway back from sides, top, and bottom to reduce visibility, paint to match existing building color. • Mounting hardware to be concealed within wireway. • Letters are to be mounted on 2" X 6" wireways, of .090 aluminum, painted to match fascia (I believe this is for Cedar Park only) Other Random Comments • Signage is limited to 2 lines of text, unless otherwise approved by LL. • See additional LL comments/notes in (color) on drawings. • Painting of awning/canopy(s) shall be done electrostatically and will be the Tenant's responsibility to maintain. • Gooseneck lighting to be removed, patch, repair, paint to like -new condition (primarily at SLTS) • Consider using perforated vinyl where blue vinyl is applied, so sign is white when lit and blue during daylight hours, as blue is difficult to read when lit.Blade Signs to be lit (Esp. at SLTS) • Routed and Push -Through Letters Typical Signage Comments TEMPORARY BANNERS/SIGNS (if allowed be lease • Temporary banners / signs are limited to 30 days, Landlord reserves the right to request they be removed at any time and/or if a complaint is filed for violation of the REA. • Tenant and sign company are responsible for cleaning the fagade, windows, sidewalks, awnings/canopies of any residue/debris from installation and repairing any damage to premises. • Installation to occur before or after business hours, coordinate with property management for specific times, and shall not block any drive aisles. • It is preferred to not anchor directly to building If not feasible: • Penetrations to be in mortar joints ONLY. • Penetrations are to be sealed, matching the existing mortar color. • Minimize number and size of penetrations in wall. • Tenant is responsible for removing signage and patching all penetrations, to match existing fagade colors, materials, conditions, etc. upon vacating premises. • If using parapet, do not penetrate roof membrane/flashing.