1252 2021 International Residential Code
ORDINANCE NO. 1252
AN ORDINANCE ADOPTING THE INTERNATIONAL RESIDENTIAL CODE, 2021
EDITION FOR ONE- AND TWO-FAMILY DWELLINGS, REGULATING THE
ERECTION, CONSTRUCTION, ENLARGEMENT, ALTERATION, REPAIR, MOVING,
REMOVAL, DEMOLITION, CONVERSION, OCCUPANCY, EQUIPMENT, USE,
HEIGHT, AREA AND MAINTENANCE OF ALL ONE- AND TWO-FAMILY
DWELLINGS AND MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES), IN
THE CITY OF SOUTHLAKE; PROVIDING FOR THE ADOPTION OF LOCAL
AMENDMENTS THERETO; PROVIDING FOR RECORDING OF SUCH CODE AS A
PUBLIC RECORD PROVIDING THAT THIS ORDINANCE SHALL BE CUMULATIVE
OF ALL ORDINANCES; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR
A PENALTY FOR VIOLATIONS HEREOF; PROVIDING A SAVINGS CLAUSE;
PROVIDING FOR PUBLICATION IN PAMPHLET FORM; PROVIDING FOR
PUBLICATION IN THE OFFICIAL NEWSPAPER; AND PROVIDING AN EFFECTIVE
DATE.
WHEREAS, the City of Southlake is a home rule city acting under its charter
adopted by the electorate pursuant to Article XI, Section 5 of the Texas Constitution and
Chapter 9 of the Local Government Code; and
WHEREAS, the City Council of the City of Southlake deems it necessary to
adopt this ordinance providing minimum standards to safeguard the health, property,
and welfare of the citizens of Southlake by regulating and controlling the use,
occupancy, maintenance, repair, design, construction and quality of materials for
residential buildings and structures within the City.
WHEREAS, beginning in the spring of 2021, NCTCOG's Regional Codes
Coordinating Committee (RCCC) and its five advisory boards conducted open review
meetings over a one-year period to review the 2021 editions of the International Codes
and to develop regional amendments. Their review and recommendations were
completed and endorsed by NCTCOG's Executive Board in July 2021. Now NCTCOG
encourages jurisdictions in North Central Texas to adopt the 2018 International
Residential Code along with its respective regional amendments.
2021 IRC 1
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
SOUTHLAKE, TEXAS:
Section 1
Adoption
That the International Residential Code for One- and Two-Family Dwellings,
2021 Edition, published by the International Code Council, including the standards
referenced therein, including Appendices A, B, C, E, G and H are hereby adopted as
the Residential Building Code of the City of Southlake regulating the erection,
construction, enlargement, alteration, repair, moving, removal, demolition, conversion,
occupancy, equipment, use, height, area and maintenance of all one- and two-family
dwellings, multiple single-family dwellings (townhouses) and their accessory structures
in the City of Southlake. A True and correct copy of this document is referenced in
Exhibit "A."
Section 2
Amendments
That the 2021 International Residential Code, as adopted herein, is hereby
amended as provided in Exhibit "B" incorporated herein and attached hereto for all
purposes of this ordinance. The City of Southlake, Texas may from time to time
determine that additional local modifications to the Building Code are necessary and
appropriate to meet the unique needs of the City of Southlake, Texas. To effectuate
these local modifications, the City Council shall enact individual ordinances amending
this Ordinance, fully setting forth the change to be made in the Residential Building
Code. Upon adoption, copies of these amendments shall be attached as Exhibit "B" to
this Ordinance.
Section 3
Recording
The material contained in Exhibits "A" and "B" to this ordinance shall not be
included in the formal municipal codification of ordinances but shall be maintained as a
public record in the office of the City Secretary and/or the office of Building Inspections
and will be available for public inspection and copying during regular business hours.
Section 4
Cumulative Clause
This ordinance shall be cumulative of all provisions of ordinances of the City of
Southlake, Texas, except where the provisions of this ordinance are in direct conflict
with the provisions of such ordinances, in which event the conflicting provisions of such
ordinances are hereby repealed. This ordinance shall not amend or replace Appendix
chapter P of the 2006 edition of the International Residential Code for One- and Two-
Family Dwellings as adopted in ordinance 937.
2021 IRC 2
Section 5
Severability
It is hereby declared to be the intention of the City Council that the phrases,
clauses, sentences, paragraphs, and sections of this ordinance are, severable, and if
any phrase, clause sentence, paragraph or section of this ordinance shall be declared
unconstitutional by the valid judgment or decree of any court of competent jurisdiction,
such unconstitutionality shall not affect any of the 'remaining phrases, clauses,
sentences, paragraphs and sections of this.-ordinance, since"the same would have been
enacted by the City Council without the"incorporation in this ordinance of any such
unconstitutional phrase, clause, sentence, paragraph or section.
Section 6
Penalty
Any person, firm or corporation who violates, disobeys, omits. neglects or refuses
to comply with or who resists the enforcement of any of the provisions of this ordinance
shall be fined not more than Two Thousand Dollars ($ 2,000.00) for all violations
involving zoning, fire safety or public health and sanitation, including dumping or refuse,
and shall be fined not more than five hundred dollars ($500) for all other violations of
this ordinance each day that a violation is permitted to exist shall constitute a separate
offense.
Section 7
Saving Clause
All rights and remedies of the City of Southlake are expressly saved as to any
and all violations of the provisions of any ordinances affecting the regulation and control
of the use, occupancy, maintenance, repair, design, construction and quality of
materials for buildings and structures within the,City which have accrued at the time of
the effective date of this ordinance;"and, as to such accrued violations and all pending
litigation, both civil and criminal, whether pending in;' court or not, under such
ordinances, same shall not be affected by this ordinance but may be prosecuted until
final disposition by the courts.
Section 8
Publication
The City Secretary of the City of Southlake is hereby authorized to publish this
ordinance in book or pamphlet form for general distribution among the public, and the
operative provisions of this ordinance as so published shall be admissible in evidence in
all courts without further proof than the production thereof.
The City Secretary of the City of Southlake is hereby directed to publish in the
official newspaper of the City of Southlake, the caption, penalty clause, publication
clause and effective date of this ordinance one time within ten days after passage of this
ordinance, as required by Section 3.13 of the Charter of the City of Southlake.
Section 10
Effective Date
This ordinance shall be in full force and effect from and after its passage and publication
as required by law but not before May 1, 2022.
2021 IRC 3
APPROVED ON FIRST READING THIS 5 DAY OF APRIL, 2022.
`%N1!Iliiiii MAYOR
OJ-.NLAKF T'�.
AntST:
_o? cn
'lam
CITY SECRETARY
flies MO%
APPROVED ON SECOND READING THIS 19 DAY OF APRIL, 2022.
MAYOR
owsioitio
•�� '�Ht_AKF ° FATTEST:
= altCITY SECRETARY
j*ice
APPROVED AS TO FORM AND LEGALITY:
(62:
CITY ATTORNEY/
PUBLISHED: N 0,31j
EFFECTIVE:
2021 IRC 4
EXHIBIT A
2021 International Residential Code Complete Edition
Located in the Building Inspections Office
1400 Main St., Suite 250
City of Southlake, Texas
76092
2021 IRC 5
EXHIBIT B
Amendments to the 2021 International Residential Code
The following sections, paragraphs, and sentences of the 2021 International Residential Code are hereby
amended as follows: Standard type is text from the IRC. Underlined type is text inserted. L ined through
type is deleted text from IRC. A double asterisk(**) at the beginning of a section identifies an amendment
carried over from the 2018 edition of the code and a triple asterisk (***) identifies a new or revised
amendment with the 2021 code.
In 2009, the State Legislature enacted SB 1410 prohibiting cities from enacting fire sprinkler mandates in
residential dwellings. However, jurisdictions with ordinances that required sprinklers for residential
dwellings prior to and enforced before January 1, 2009, may remain in place. Reference; Section R313
Automatic Fire Sprinkler Systems.
The energy provisions in IRC Chapter 11 is deleted in its entirety.
Reference the 2021 IECC for energ code •rovisions and recommended amendments.
**Section R102.4;change to read as follows:
R102.4 Referenced codes and standards. The codes, when specifically adopted. and standards
referenced in this code shall be considered part of the requirements of this code to the prescribed extent
of each such reference and as further regulated in Sections R102.4.1 and R102.4.2. Whenever
amendments have been adopted to the referenced codes and standards, each reference to said code
and standard shall be considered to reference the amendments as well. Any reference made to NFPA 70
or the Electrical Code shall mean the Electrical Code as adopted.
(Reason: Legal wording to recognize locally adopted codes and amendments adopted with referenced
codes.)
s!, v . _._.._..._4 r... tE _. .. _ ,, .._. _... . ._.�.x _r s•
4..
**Section R103;amend to read as follows:
DEPARTMENT OF BUI1 DING SAFETY City of Southlake Building Inspections Department
103.1 Creation of an enforcement agency. The Department of Building Safety, City of Southlake
Building Inspections Department, is hereby created and the official in charge thereof shall be known as
the Building Official.
(Reason: To correlate the department name with what it is actual) called in this city.)
**Section R104.10.1 Flood Hazard areas; delete this section.
Reason: Flood hazard ordinances ma be administered b other de•artments within the city.
f:
**Section R105.1:amend to read as follows:
Permits Required. Any owner or owner's authorized agent who intends to construct, enlarge, alter,
repair, move, demolish, or change the occupancy of a building or structure, to excavate or change the
grade of any property, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical,
gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any
such work to be performed, shall first make application to the building official and obtain the required
permit.
(Reason: Consistent with previous edition amendment, to provide means to regulate grading affecting
other •ro•erties)
., ,.. ...-. .;• x,1„� :�..•:. p .-.
**Section R105.2; Work exempt from permit. Amend to read as follows:
2021 IRC 6
Building:
1. One-story detached accessory structures used as tool and storage sheds, playhouses and similar
uses, provided the floor area does not exceed 200 120 square feet(11.15 m2).
2. Fences not over 7 feet nominal(1829 mm) high except masonry fences or support columns.
3. —9. (No change)
10. Decks not exceeding 200 square feet (18.58 m2) in area, that are not more than 30 inches (762
mm) above grade at any point, are not attached to a dwelling and do not serve the exit door
required by Section R311.4.
11. Residential foundation repairs performed for the purpose of stabilizing an existing foundation
without the removal of any existing concrete, except for the installation of new piers, pilings, or
other associated support.
Grading:
1) Grading in an isolated, self-contained area, provided there is no danger to the public, and that
such grading will not adversely affect adjoining properties.
2) Excavation for construction of a structure permitted under this code.
3) Cemetery graves.
4) Refuse disposal sites controlled by other regulations.
5) Excavations for wells, or trenches for utilities.
6) Mining, quarrying, excavating, processing or stockpiling rock, sand, gravel, aggregate or clay
controlled by other regulations, provided such operations do not affect the lateral support of, or
significantly increase stresses in soil on adjacent properties.
7) Exploratory excavations performed under the direction of a registered professional engineer.
Exemption from the permit requirements of this section shall not be deemed to grant authorization for
any work to be done in any manner in violation of the provisions of this code or any other laws or
ordinances of this jurisdiction.
(Reason: No inspections or other services are provided for this type of permit.)
**Section R105.3.1.18 R106.1.4;delete these sections.
(Reason: Floodplain provisions are addressed locally.)
**Section R108;amend R108.6 and add R108.6.1 and R108.6.2 to read as follows:
R108.6 Work commencing before permit issuance. Any person who commences work requiring a
permit on a building, structure, electrical, gas, mechanical or plumbing system before obtaining the
necessary permits shall be subject to a fee established by the applicable governing authority below that
and shall be in addition to the required permit fees.
R108.6.1 Investigation. Whenever work for which a permit is required by this code has been
commenced without first obtaining a permit, a special investigation shall be made before a permit may be
issued for such work.
R108.6.2 Fee.An investigation fee, in addition to the permit fee, shall be collected whether or not a permit
is subsequently issued. The investigation fee shall be equal to the amount of the work completed up to
the total permit fee as required by this code or the city fee schedule as applicable. The payment of such
investigation fee shall not exempt the applicant from compliance with all other provisions of either this
code or the technical codes nor from penalty prescribed by law.
(Reason: This fee is not a fine or penalty but is designed to compensate for time and to remove incentive
to attempt to evade permits and code compliance. Text taken from former Uniform Administrative Code.)
**Section R108;add R108.7 and R108.8 to read as follows:
R108.7 Unauthorized cover up fee. Any work concealed without first obtaining the required inspection in
violation of Section 109 shall be assessed a fee as established by the city fee schedule.
2021 IRC 7
R108.8 Re-inspection Fee.A fee as established by city council resolution may be charged when:
1. Work called for inspection is incomplete;
2. Building address and/or permit card is not clearly posted;
3. City approved plans are not on the job site available to the inspector;
4. The building is locked or work otherwise not available for inspection when called;
5. Items noted for correction on initial inspection and not corrected upon re-inspection.
6. The original red tag has been removed from the job site and/or,
7. Violations exist on the property including failure to maintain erosion control, trash control or tree
protection.
Any re-inspection fees assessed shall be paid before any more inspections are made on that job site.
(Reason: These fees are not a fine or penalty but are designed to compensate for additional time
necessary to obtain and verify code compliance. Language taken from former Uniform Administrative
Code.)
**Section R109.1.3; amend to read as follows:
R109.1.3 Floodplain inspections. For construction permitted in areas prone to flooding as established
by Ordinance 641 Table R301.2(1), upon . . . (bulk of section unchanged} . . . construction, the building
official may Mall require submission . . . (remainder of section unchanged).
(Reason: Confirmation of elevation is left to local discretion.)
4�"{9"•r ,fi"s,:'M
�"
**Section R110(R110.1 through R110.5); Certificate of Occupancy. Delete the section.
(Reason: Issuing CO's for residences is not a common practice in the area.)
o.r,�.,.,.'dJ,•:'1" ey.," :.�a'✓''�'t,:':
***Section R202;change definition of"Townhouse Unit"to read as follows:
TOWNHOUSE UNIT. A single-family dwelling unit separated by property lines in a townhouse that
extends from foundation to roof and that has a yard or public way on not less than two sides.
n.:,,....F s, . , e crate lots.
(Reason: To distinguish Townhouse Units within a Townhouse building on s
.gig ,:s :. .: ,
**Table R301.2 (1);fill in as follows:
GROUND SEISMIC SUBJECT TO
SNOW WIND DESIGN DESIGNCATEGORYf DAMAGE FROM w
LOAD F u) w J
E z o w _ Q
�_ •
a) ce
A Weathe i 9& Q W L O 2 LL X z� 0
SPEED- a- 5 E o ring Frost Termite° Z W } of Q re o w z w
(MPH) rn w m o 0 .n a Line b o V g a x ¢ ? Q -
5Ib/ft o a Er � Depth
I- W u) IY -0
115 O
gust)/76 No No No Modera 6„ Hea 22° F No U 150 64.9°
�v Very
fastest
mile
Delete remainder of table Manual J Design Criteria and footnote N
(Reason: To promote regional uniformity. Manual J is utilized by third party and not part of performed
fan reviews. Reference table only, not needed.)
,.,'H ..,,,_ .,,iuK+:'^*,,,,.:+>.�:i.•.s,,�a�'..,,. ._ .. ,",r,:"r.,�, rt�:;�:yf;;` ... .,,sW:�:f ... ...a..
**Section R302.1;Exterior walls. Add exception#6 to read as follows:
Exceptions: (previous exceptions unchanged}
6. Open non-combustible carport structures may be constructed when also approved within
adopted ordinances.
2021 IRC 8
Reason Refers to other ordinances, such as zoning ordinances.) x�
at' " it r. 3a '�F yea :`"'S 3,,' ,' .,� C ,x"
***Section R302.2.6; delete exception#6:
Exceptions: {previous exceptions unchanged}
6. Townhouse units protected by a fire sprinkler system complying with Section P2904 or NFPA
13D.
(Reason: To remain consistent with separated townhouse units and property lines.)
**Section R302.3;add exception #3 to read as follows:
Exceptions:
1. {existing text unchanged}
2. {existing text unchanged}
3. Two-family dwelling units that are also divided by a property line through the structure shall
be separated as required for townhouses.
(Reason: Provide guidance for a common construction method in this area. Correlates with amendment
to IRC Section R202 Townhouse definition.)
�4 1
., zmvf• a,.�`e,1 0 `Ei"r': ..av'�,�'X�'., y
**Section R302.5.1; change to read as follows:
R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping
purposes shall not be permitted. Other openings between the garage and residence shall be equipped
with solid wood doors not less than 13/8 inches (35 min) in thickness, solid or honeycomb core steel
doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors equipped with a elf-^losing
devise.
(Reason:Absence of data linking self-closing devices to increased safety. Self-closing devices often fail
to close the door entir�'�e���Cl/entirely)+'�..<,.,,. t ...v .� ' 93.'jcl .sk .ri x 1 't`e#Y,�'Yi" +T;: le,
� ,
**Section R303.3, Exception:amend to read as follows:
Exception: (existing text unchanged} Spaces containing only a water closet, a lavatory, or
combination thereof may be ventilated with an approved mechanical recirculating fan or similar device
designed to remove odors from the air.
(Reason: Consistent with common local practice as recirculating fans are recognized as acceptable air
movement.)
::::l !" . 1 ;r..... i' "
***Add Section R307.3 and R307.4
R307.3 Blocking. Required at one toilet at grade level. Blocking per Sec. R307.4 and Figure 307.4, shall
be installed at rear wall and one wall adjacent to toilet at the lowest living level where a toilet is provided.
R307.4 Blocking. Blocking may be plywood or equivalent or 2 x solid wood blocking flush with wall.
34' - 36" 24" — 45" 0"
1' * r 1/2" Ptwd.
btockinr • 2 x blocking—y►
r -r i tli wait wall
I crea of blocking I I creo of blocking I
E d
E
1 s
2021 I1'01
(Reason: Blocking at initial construction allows for ease of use for future grab bar installation if desired for
homeowners. Ties into Dallas Builders Association of Universal Design Elements concepts for CAPS
(Certified Aging in Place Specialists)professionals.)
**Section R313 Automatic Fire Sprinkler Systems. Amend to read as follows:
See Appendix P as adopted with Ordinance 937.
AP101 Fire sprinklers. An approved automatic fire sprinkler system shall be installed in new one- and
two-family dwellings and townhouses in accordance with Section 903.3.1 of the International Building
Code.
EXCEPTION: Dwellings containing less than 6000 square feet enclosed space. For upper level
attic type rooms, areas where the ceiling height is less than five feet (5' 0") shall not be
considered. Unfinished space framed to permit future expansion of floor area shall be considered
as part of the area. Joists designed to support floor loads shall be assumed to be for future area.
(Living area plus garages and any other enclosed spaces but not open porches or patios).
AP101.1 Existing dwellings. An approved automatic fire sprinkler system shall be installed in existing
dwellings in accordance with Section 903.3.1 of the International Building Code when the existing
dwelling plus the proposed addition exceeds 6000 square feet enclosed space (living area plus garages
and any other enclosed spaces but not open porches or patios).
Exception: Existing unfinished space under roof(e.g. bonus space in attic) may be converted to
living area unless the existing dwelling is already sprinklered, then the protection shall be
extended to include the new area.
(Reason: In 2009, the State Legislature enacted SB 1410, amending section 1301.551 subsection I of the
occupation code, prohibiting cities from enacting fire sprinkler mandates in residential dwellings only.
However, jurisdictions with ordinances that required sprinklers for residential dwellings prior to and
enforced before January 1, 2009, may remain in 'lace.)
. -
.......<. ,. ., •,,.+'e i 1 _
**Section R315.2.2 Alterations, repairs and additions. Amend to read as follows:
Exception:
1. [existing text remains]
2. Installation, alteration or repairs of all electrically powered mechanical systems or plumbing
appliances.
(Reason: Code intent is to •rotect against the products of combustion.
. i., .�,•.,. .,... 3L ..,w..a,.n i✓.xe i`'...:„ sw. ....
**Section R319.1;amend to read as follows:
R321.1 Address identification. Buildings shall be provided with approved address identification. See
Ordinance#441 for specific addressing requirements. {Delete remainder of section.}
(Reason: Call attention to addressing ordinance.
**Section R322 Flood Resistant Construction; deleted section.
(Reason: Floodplain hazard ordinances are administered b other de•artments within the cit )
y✓ ,_, _. . u,r ......,x.�::G r.• _ :,
***Section 327.1.1; add to read as follows:
2021 IRC 10
Section 327.1.1 Adjacency to Structural Foundation. Depth of the swimming pool and spa shall
maintain a ratio of 1:1 from the nearest building foundation or footing of a retaining wall.
Exception:
A sealed engineered design drawing of the proposed new structure shall be submitted for approval.
(Reason: To clarif s•ecific distances for ••ools and s•as.)
'Section R401.2, amend by adding a new paragraph following the existing paragraph to read as
follows.
Section R401.2. Requirements. (existing text unchanged) ...
Every foundation and/or footing, or any size addition to an existing post-tension foundation, regulated by
this code shall be designed and sealed by a Texas-registered engineer.
(Amendment to 2015 &2018 IRC carried forward to 2021 IRC.)
**Section R602.6.1;amend the following:
R602.6.1 Drilling and notching of top plate.When piping or ductwork is placed in or partly in an exterior
wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than 50
percent of its width, a galvanized metal tie not less than 0.054 inch thick (1.37 mm) (16 Ga) and 4-4
inches (38) mm 5 inches (127 mm) wide shall be fastened across and to the plate at each side of the
opening with not less than eight 10d (0.148 inch diameter) having a minimum length of 1 1/z inches (38
mm) at each side or equivalent. Fasteners will be offset to prevent splitting of the top plate material. The
metal tie must extend a minimum of 6 inches past the opening. See figure R602.6.1. {remainder
unchanged}
(Reason:reflects regional practice and to comply with P2603.2.1. Also provides additional assurance of
maintain the integri of the framing by s•reading the nailing ••attern.
**Figure R602.6.1;delete the figure and insert the following figure: .
EXTERIOR OR SEARING WALL
NOTCH GREATER THAN 50 �I
PERCENT OF THE PLATE WID ��►
16 GAGE 6054 IN.)AND 5IN.WIDE
11
METAL TIE FASTENED ACROSS AND
.TO THE PLATE AT EACH SIDE OF THE
NOTCH WRH 8-106 NAILS EACH SIDE
TOP PLATES
PIPE
2021 IRC 11
(Amendment to 2015 &2018 1RC carried forward to 2021 IRC also provides additional assurance of
maintaining the integrity of the framing by spreading the nailing pattern.)
_T %s'i tSk'w. 't ..J"" . .-ni.«:/.�ti f l,y�7Pr...
'rx.
**Section R703.8.4.1.2; Veneer Ties for Wall Studs. add to read as follows:
In stud framed exterior walls, all ties shall be anchored to studs as follows:
1. When studs are 16 in (407 mm) o.c., stud ties shall be spaced no further apart than 24 in (737
mm)vertically starting approximately 12 in (381 mm) from the foundation; or
2. When studs are 24 in (610 mm) o.c., stud ties shall be spaced no further apart than 16 in (483
mm)vertically starting approximately 8 in (254 mm) from the foundation.
(This amendment had been a carry-over amendment for years to provide clear instruction for placement
of brick ties. It is now retained with changes to reflect its correct placement and use for clarity when
attachment to framing lumber(studs). It should remain for those purposes. It is in addition to the Table in
2018 which provides for brick ties directly to sheathing.)
**Section R902.1;Amend and add exception #5 to read as follows:
R902.1 Roofing covering materials. Roofs shall be covered with materials as set forth in Sections R904
and R905. Class A, B, or C roofing shall be installed in jurisdictions designated by law as requiring their
use or when the edge of the roof is less than 3 feet from a lot line. (remainder unchanged}
Exceptions:
1. {text unchanged}
2. {text unchanged}
3. {text unchanged}
4. {text unchanged}
5. Non-classified roof coverings shall be permitted on one-story detached accessory structures
used as tool and storage sheds, playhouses and similar uses, provided the floor area does
not exceed (area defined by jurisdiction 120 square feet).
(Reason: to address accessory structures Group U exempt from permits per Section R105.2)
.,. ..,
**Chapter 11(REI—Energy Efficiency is deleted in its entirety;Reference the 2018 IECC for
energy code provisions and recommended amendments.
(Reason: The recommended energy code changes from the Energy and Green Advisory Board update
the amendments for Chapter 11. The 2021 International Energy Conservation Code should be
referenced for residential energy provisions. This approach simply minimizes the number of amendments
to the IRC.)
**Section M1305.1.2;amend to read as follows:
M1305.1.2 Appliances in attics. Attics containing appliances shall be provided . . . (bulk of paragraph
unchanged) . . . sides of the appliance where access is required. The clear access opening dimensions
shall be not less than 20 inches by 30 inches (508 mm by 762 mm), or larger and large enough to allow
removal of the largest appliance. A walkway to an appliance shall be rated as a floor as approved by the
building official. As a minimum, for access to the attic space, provide one of the following:
1. A permanent stair.
2. A pull down stair with a minimum 300 lb (136 kq) capacity.
3. An access door from an upper floor level.
2021 IRC 12
4. Access Panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due
to building conditions.
(Reason: To provide a safe means of accessibility to appliances in attics and to allow for different types
of construction limitations. Consistent with regional amendment to IPC 502.3, IFGC 306.3 and IMC
306.3.)
**Section M1411.3;amend to read as follows:
M1411.3 Condensate disposal. Condensate from cooling coils and evaporators shall be conveyed from
the drain pan outlet to an approved place of disposal a sanitary sewer through a trap, by means of a
direct or indirect drain. (remaining text unchanged}
(Reason: Reflects regional practice and to reduce excessive runoff into storm drains.)
d ,
**Section M1411.3.1, Items 3 and 4;add text to read as follows:
M1411.3.1 Auxiliary and secondary drain systems. (bulk of paragraph unchanged}
1. (text unchanged}
2. (text unchanged}
3. An auxiliary drain pan... (bulk of text unchanged}... with Item 1 of this section. A water level
detection device may be installed only with prior approval of the building official.
4. A water level detection device... (bulk of text unchanged}... overflow rim of such pan. A water
level detection device may be installed only with prior approval of the building official.
(Reason: Reflects standard .ractice in this area.)
_x v .._. s,_ :,a t � erva k`K' a ua� ''> e `7€ �t[sk� cr'FSF "
'Section M1411.3.1.1;add text to read as follows:
M1411.3.1.1 Water-level monitoring devices. On down-flow units ...(bulk of text unchanged}... installed
in the drain line. A water level detection device may be installed only with prior approval of the building
official.
(Reason: Reflects standard practice in this area.)
**M1503.6 Makeup Air Required. Amend and add exception as follows:
M1503.6 Makeup air required. Where one or more gas, liquid or solid fuel-burning appliance that is
neither direct-vent nor uses a mechanical draft venting system is located within a dwelling unit's air
barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s)
shall be mechanically or passively provided with makeup air at a rate approximately equal to the
difference between exhaust air rate and 400 cubic feet per minute. Such makeup air systems shall be
equipped with not fewer than one damper complying with Section M1503.6.2.
Exception: Makeup air is not required for exhaust systems installed for the exclusive purpose of space
cooling and intended to be operated only when windows or other air inlets are open. Where all appliances
in the house are of sealed combustion, power-vent, unvented, or electric, the exhaust hood system shall
be permitted to exhaust up to 600 cubic feet per minute (0.28 m3/s) without providing makeup air.
Exhaust hood systems capable of exhausting in excess of 600 cubic feet per minute (0.28 m3/s) shall be
provided with a makeup air at a rate approximately to the difference between the exhaust air rate and 600
cubic feet per minute.
(Reason: Exception requires makeup air equaling the amount above and beyond 400 cfm for larger fan
which will address concerns related to "fresh" air from the outdoors in hot humid climates creating a
burden on HVAC equipment and negative efficiency impacts from back-drafting and wasted energy.
Consistent with IMC 505.4)
2021 IRC 13
**Section M2005.2;change to read as follows:
M2005.2 Prohibited locations. Fuel-fired water heaters shall not be installed in a room used as a
storage closet. Water heaters located in a bedroom or bathroom shall be installed in a sealed enclosure
so that combustion air will not be taken from the living space. Access to such enclosure may be from the
bedroom or bathroom when through a solid door, weather-stripped in accordance with the exterior door
air leakage requirements of the International Energy Conservation Code and equipped with an approved
self-closing device. Installation of direct-vent water heaters within an enclosure is not required.
(Reason: Corres•onds with the •rovisions of IFGC Section 303.3, exce•tion #5.
**Section G2408.3;Private Garages;delete section in its entirety.
(Reason: This •rovision does not reflect standard •ractice in this area. Corres•onds with IFGC 305.5)
**Section G2415.2.1 CSST;add a subsection to read as follows:
G2415.2.1 Gas Pressure labeling. Both ends of each section of medium pressure pas piping shall
identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or
stainless steel and the following wording shall be stamped into the tag:
"WARNING: 1/2 to 5 psi gas pressure - Do Not Remove"
(Reason: To •rotect homeowners and •lumbers. Corres•onds with IFGC 404.2.1)
,.tier., .ram,,ar_:3;< .,ate.•
.
**Section G2415.12 and G2415.12.1; change to read as follows:
G2415.12 Minimum burial depth. Underground piping systems shall be installed a minimum depth of 42
inches (305 mm) 18 inches (457 mm) below grade, except as provided for in Section G211 L '17
G2415.12.1 Individual Outdoor Appliances;Delete in its entirety
(Reason: To •rovide increased •rotection to •i•ing systems. Corres•onds with IFGC 404.12
n x nr¢ v'v`'- x r �
.._ � z%�.��.el_.,.._,..._�_E,,..e..,,_,Ps�.F•�.•�.•.�xx.,.,ks2�wa,`�l..u,...,._•afi�.+�:w`.x�,.✓�.,.�ii.;g,....a�'r3�.'a�,I„'.+Y.,��n:".x`�"�`,e�"�:wf% c �' r f
**Section G2417.1;change to read as follows:
G2417.1 General. Prior to acceptance and initial operation, all piping installations shall be visually
inspected and pressure tested to determine that the materials, design, fabrication, and installation
practices comply with the requirements of this code. The permit holder shall make the applicable tests
prescribed in Sections 2417.1.1 through 2417.1.5 to determine compliance with the provisions of this
code. The permit holder shall give reasonable advance notice to the building official when the piping
system is ready for testing. The equipment, material, power and labor necessary for the inspections and
test shall be furnished by the permit holder and the permit holder shall be responsible for determining that
the work will withstand the test pressure prescribed in the following tests.
(Reason: To utilize language used in the IFGC 406.1 regarding who is responsible for testing
•rocedures)
. ir�,Y - >'
3 ..�. ;,1'.4-:YV: s .: a.' 's dud
s!'er...v.. z.._ ,n .. .h'� ,�.�.Y.✓: . ,.;�. � b..,-,�✓�=�.a. 3'�s,..r.�_w,,...-, �
**Section G2417.4.1; change to read as follows:
G2417.4.1Test pressure. The test pressure to be used shall be no less than 1 1/2 times the proposed
maximum working pressure, but no less than 3 psig (20 kPa gauge), or at the discretion of the Code
Official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury,
measured with a manometer or slope gauge. irrespectiveesign ssure. `^here the test pressure
stress in the piping greater than 50 percent of the specified minims yield strength of the pipe. For tests
requiring a pressure of 3 psiq, diaphragm gauges shall utilize a dial with a minimum diameter of three and
one half inches (3 1/2"), a set hand, 1/10 pound incrementation and pressure range not to exceed 6 psi for
tests requiring a pressure of 3 psiq. For tests requiring a pressure of 10 psiq, diaphragm gauges shall
2021 IRC 14
utilize a dial with a minimum diameter of three and one-half inches (3 1/2'), a set hand, a minimum of 2/10
pound incrementation and a pressure range not to exceed 20 psi. For welded piping, and for piping
carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (1/2 psi)
and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be
less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds
200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half
times the proposed maximum working pressure.
Diaphragm gauges used for testing must display a current calibration and be in good working condition.
The appropriate test must be applied to the diaphragm gauge used for testing
(Reason: To provide for lesser pressures to coordinate with the use of more accurate diaphragm gauges.
Corres•onds to IFGC 406.4.1)
'Section G2417.4.2; change to read as follows:
G2417.4.2 Test duration. The test duration shall be held for a length of time satisfactory to the Building
Official, but in no case for be-net less than 1-0-fifteen (15) minutes. For welded piping, and for piping
carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa), the test
duration shall be held for a length of time satisfactory to the Building Official, but in no case for less than
thirty (30) minutes.
(Reason: To com•1 with acce•ted regional .ractices. Corres•onds with IFGC 406.4.2)
.,._.,.,.......,. • ,.:. :,.,., _..�.:,.. ... -.._.._�..s.:F.
*"`Section G2420.1;add Section G2420.1.4 to read as follows:
G2420.1.4 Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST)
piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for
the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp
out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall
be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings,
and valves between anchors. All valves and supports shall be designed and installed so they will not be
disengaged by movement of the supporting piping.
(Reason: To provide proper security to CSST valves. These standards were established in this region in
1999 when CSST was an emerging technolog . Corres•onds with IFGC 409.1.4)
sx. , sr....- , _..,._ .� ,..,,.,_ _ ,.,. - -_...,..,., ..,.,..,.._............v,c;...x,..3.,+_.., ;:✓.w.....Wtvt<ru` r,.�n;'SF�i,.a,« se� ; `",` :u'
**Section G2420.5.1;add text to read as follows:
G2420.5.1 Located within the same room. The shutoff valve ...(bulk of paragraph unchanged}... in
accordance with the appliance manufacturer's instructions. A secondary shutoff valve must be installed
within 3 feet(914 mm) of the firebox if appliance shutoff is located in the firebox.
(Reason: Reflects regional practice and provides an additional measure of safety. Corresponds with IFGC
409.5.1)
ssr. •. .
**Section G2421.1;add text and exception to read as follows:
G2421.1 Pressure regulators. A line pressure regulator shall be ... (bulk of paragraph unchanged}...
approved for outdoor installation. Access to regulators shall comply with the requirements for access to
appliances as specified in Section M1305.
Exception: A passageway or level service space is not required when the regulator is capable of
being serviced and removed through the required attic opening.
(Reason: To require adequate access to regulators. Corresponds with IFGC 410.1)
..t,, . . .. , ._..,_., .. .u.w.. 7.7
`Section G2422.1.2.3;Prohibited locations and penetrations. Delete Exception 1 and Exception 4.
(Reason: To comply with accepted regional practices. Corresponds with IFGC 411.1.3.3)
2021 IRC 15
**Section G2445.2;add exception to read as follows:
G2445.2 Prohibited use. One or more unvented room heaters shall not be used as the sole source of
comfort heating in a dwelling unit.
Exception: Existing approved unvented room heaters may continue to be used in dwelling units, in
accordance with the code provisions in effect when installed, when approved by the Building Official
unless an unsafe condition is determined to exist as described in International Fuel Gas Code Section
108.7.
(Reason: Gives code official discretion. Corres•onds with IFGC 621.2)
Section G2448.1.1;add to read as follows:
G2448.1.1 Installation requirements. The requirements for water heaters relative to access, sizing,
relief valves, drain pans and scald protection shall be in accordance with this code
(Reason: To clarify installation requirements. Also corresponds with amendments regarding water heater
access. Corres•onds to IFGC 624.1.1)
r...,a:,:
**Section P2603; change to read as follows:
P2603.3 Protection against corrosion. Metallic piping, except for cast iron, ductile iron and galvanized
steel, shall not be placed in direct contact with steel framing members, concrete or cinder walls and floors
or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing
is used to prevent direct contact, the sheathing shall have a thickness of not less than 0.008 inch (8 mil)
(0.203 mm) and the sheathing shall be made of approved material plastic. Where sheathing protects
piping that penetrates concrete or masonry walls or floors, the sheathing shall be installed in a manner
that allows movement of the piping within the sheathing.
Reason: Allows for other materials to be acce•ted. Corres•onds with IPC 305.1)
_._...,..;.... a...,. ..._ � .�.:. x.�.,..,. u,...> _._..,,,_,... • . .,_s• •_... ,;,_.,u•
**Section P2603.5.1 Sewer Depth;change to read as follows:
P2603.5.1 Sewer depth. Build'„ ing-sewers--th,,at onnect te-pr-ivate sewage disposal s„stems shall be
minimum of [number] inches (mm) below finished grade at the point of septic tank connection. Building
sewers shall be a minimum of 12 inches (304 mm) below grade.
(Reason: Provides sewer depth that is common in this region. Deleted reference to private sewage
disposal because a private sewage disposal code is not typically adopted in this region. Corresponds with
IPC 305 4 1)
s. ',..r"::c.....�i.�., s,n.u.•
,.._. ._;xr,,.,'rt. r� 5c:"✓r`,.�fr'M%r'i:' ^,a�' is5k
**Section P2604;add to read as follows:
P2604.3.1 Plastic sewer and DWV piping installation. Plastic sewer and DWV piping installed
underground shall be installed in accordance with the manufacturer's installation instructions. Trench
width shall be controlled to not exceed the outside the pipe diameter plus 16 inches or in a trench which
has a controlled width equal to the nominal diameter of the piping multiplied by 1.25 plus 12 inches. The
piping shall be bedded in 4 inches of granular fill and then backfilled compacting the side fill in 6-inch
layers on each side of the piping. The compaction shall be to minimum of 85 percent standard proctor
density and extend to a minimum of 6 inches above the top of the pipe.
(Reason: To follow manufacturer backfill re•uirements and to be clear to Ins.ectors out in the field.)
** Section P2801.6; change to read as follows:
P2801.6 Required pan.
2021 IRC 16
Where a storage tank-type water heater or a hot water storage tank is installed in a location where water
leakage from the tank will cause damage, the tank shall be installed in a pan constructed of one of the
following:
1. Galvanized steel or aluminum of not less than 0.0236 inch (0.6010 mm) in thickness.
2. Plastic not less than 0.036 inch (0.9 mm) in thickness.
3. Other approved materials.
A plastic pan shall not be installed beneath a gas-fired water heater. ben ath a gas fircd water heater
shall be constructed of material having a flame spread index of 25 or less and a smoke developed index
of 150 or lees when tested in accordance with ASTM E81 or UL 723.
(Reason: Plastic burns degrading material over time on gas fired water heaters and to maintaining
protection level. Corres•onds to 1PC 504.7 unamended)
mow.. , _' _�_,......,'..,_,,.._......._:... �._....:. .,..,.,_, ,:..._....:....,,........ ...,,.�. <,.os y, .> ... �...,..,..�:......: ,.,s.... .. �.:.J-,a�✓d.-..,f/.x_...w...9....,:,,,. 3 r.,...... .. _..,:...a,--:..,, ..
Si
**Section P2801.6.1; change to read as follows:
Section P2801.6.1 Pan size and drain. The pan shall be not less than 1% inches (38 mm) in depth and
shall be of sufficient size and shape to receive all dripping or condensate from the tank or water heater.
The pan shall be drained by an indirect waste pipe having diameter of not less than '/ inch (19 mm).
Piping for safety pan drains shall be of those materials listed in Table P2906.5. Multiple pan drains may
terminate to a single discharge piping system when approved by the administrative authority and
permitted by the manufactures installation instructions and installed with those instructions. {existing text
unchanged}
(Reason: Regionallyacce•ted practice. Corres•onds with IPC 504.7.1)
....,t,.,.
** Section P2804.6.1; change to read as follows:
Section P2804.6.1 Requirements for discharge piping. The discharge piping serving a pressure relief
valve, temperature relief valve or combination thereof shall:
1. Not be directly connected to the drainage system.
2. Discharge through an air gap located in the same room as the water heater.
3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size
to the air gap.
4. Serve a single relief device and shall not connect to piping serving any other relief device or
equipment.
Exception: Multiple relief devices may be installed to a single T & P discharge piping system
when approved by the administrative authority and permitted by the manufactures installation
instructions and installed with those instructions.
5. Discharge to the floor, to the pan serving the water heater or storage tank, to a waste
receptor an approved location or to the outdoors.
{remainder unchanged}
Reason: To ensure the T&P is ran to the exterior. Corresponds with IPC 504.6
tte•,..:x%,,,< � : � ,..�. � � £rC�zE.:z?.,. ..�... ��..,�. �� ° � aY:s : ��S�.;r� � s .�� �� x?s�...�r
**Section P2902.5.3; change to read as follows:
P2902.5.3 Lawn irrigation systems. The potable water supply to lawn irrigation systems shall be
protected against backflow by an atmospheric-type vacuum breaker, a pressure-type vacuum breaker a
double-check assembly or a reduced pressure principle backflow prevention assembly. {remainder
unchanged}
(Reason: To recognize regional practices. Corresponds with IPC 608.17.5)
2021 IRC 17
**Section P3003.9.2; delete exceptions as follows:
P3003.9.2. Solvent cementing. Joint surfaces shall be clean and free from moisture. A purple primer that
conforms to ASTM F 656 shall be applied. Solvent cement not purple in color and conforming to ASTM D
2564, CSA B137.3, CSA B181.2 or CSA B182.1 shall be applied to all joint surfaces. The joint shall be
made while the cement is wet and shall be in accordance with ASTM D 2855. Solvent cement joints shall
be permitted above or below ground
Exception• A primer is not required where all of the following conditions apply•
1. The solvent cement used is third-party certified as conforming to ASTM D 25611
The selvent cement is used only forjoining-PVC drain, was , and-ve;t pi�.pe and
fittings in not pressure applications in sizes up to and including '1 inches (102mm) in
diameter.
Reasoning: to kee. the •rocess of joining PVC •i.e. Corresponds to IPC 705.10.2)
**Section P3111; Combined waste and vent system. Delete section.
(Reason:A combination waste and vents stem is not a.•roved for use in residential construction.)
**Section P3112.2; delete and replace to read as follows:
P3112.2 Installation. Traps for island sinks and similar equipment shall be roughed in above the floor
and may be vented by extending the vent as high as possible, but not less than the drainboard height and
then returning it downward and connecting it to the horizontal sink drain immediately downstream from
the vertical fixture drain. The return vent shall be connected to the horizontal drain through a wye-branch
fitting and shall, in addition, be provided with a foot vent taken off the vertical fixture vent by means of a
wye-branch immediately below the floor and extending to the nearest partition and then through the roof
to the open air or may be connected to other vents at a point not less than six (6) inches (152 mm) above
the flood level rim of the fixtures served. Drainage fittings shall be used on all parts of the vent below the
floor level and a minimum slope of one-quarter (1/4) inch per foot (20.9 mm/m) back to the drain shall be
maintained. The return bend used under the drain-board shall be a one (1) piece fitting or an assembly of
a forty-five (45) degree (0.79 radius), a ninety (90) degree (1.6 radius) and a forty-five (45) degree (0.79
radius) elbow in the order named. Pipe sizing shall be as elsewhere required in this Code. The island
sink drain, upstream of the return vent, shall serve no other fixtures. An accessible cleanout shall be
installed in the vertical portion of the foot vent.
(Reason: To clarify the installation of island venting and to provide a regional guideline on a standard
installation method for this region. Corresponds with IPC 916.2)
�,'.. ..., .. ,.., «/�.....�a..� p��x�ross+�2„w��dy�k ���.�:,xh�s ,f, •..,t„
END
2021 IRC 18
Beaufort Gazette The Herald-Rock Hill el Nuevo Herald-Miami Sun News-Myrtle Beath
Belleville News-Democrat Herald Sun-,Durham Modesto Bee The News Tribune Tacoma
Bellingham Herald Idaho Statesman Raleigh News&,Observer The Telegraph-Macon
AN1vLCCLATCHY Centre Deity Times Kansas City Star Sacramento Bee Tri-City Herald
Charlotte Observer Lexington Herald-Leader Fort Worth Star Telegram Wichita Eagle
Columbus'Ledger-Enquirer Merced Sun-Star The State-Columbia
Fresno Bee Miami Herald Sun'Herald-Biloxi
Page 1 of 1
CITY OF SOUTHLAKE MEMO INVOICE.,..
1400 MAIN ST
STE 440 Order No.: 242377
SOUTHLAKE TX 760927604 Memo Date: 04/04/2022
Bill-To Account: 36037
Sales Rep: Haley Martin
• Billed Times
Dates Order No: Description Product Size Units Run Net Amount
04/03/2022-04/03/2022 242377 Print Legal Ad FTW-Star-Telegram 1 x 52 L 52 L 1 $108.99
IPL0067379 Legal I Legals&Public Notices CLS
PO:22200127
0 1 01\ No :
iyiwo V1161
12ii it 52
po l l 1153
yu
°IA1147
Vl/ 01 IZstI
vL5Q 1755
Please Return This Portion With Your Payment(Thank You)
MEMO INVOICE'
McClatchy Company LLC Order No.: 242377
PO Box 510150 Account No.: 36037
Livonia MI 48151
Account Name: CITY OF SOUTHLAKE
Order Amount: $108.99
*** MEMO INVOICE ***
Email questions to ssccreditandcollections@mcclatchy.com
CITY OF SOUTHLAKE
1400 MAIN ST McClatchy Company LLC
STE 440 PO Box 510150
SOUTHLAKE TX 760927604 Livonia MI 48151
Beaufort Gazette The Herald-Rock Hill el Nuevo Herald-Miami Sun News-Myrtle Beach
Belleville News-Democrat Herald Sun-Durham Modesto Bee The News Tribune Tacoma
Bellingham Herald Idaho Statesman Raleigh News&Observer The Telegraph-Macon
Bradenton Herald Island Packet The Olympian San Luis Obispo Tribune
AliMCCLATCHY Centre Daily Times Kansas City Star Sacramento Bee Tri-City Herald
Charlotte Observer Lexington Herald-Leader Fort Worth Star-Telegram Wichita Eagle
Columbus Ledger-Enquirer Merced Sun-Star The State-Columbia
Fresno Bee Miami Herald Sun Herald Biloxi
AFFIDAVIT OF PUBLICATION
Account# Order Number Identification Order PO Amount Cols Depth
36037 242377 Print Legal Ad-IPL0067379 22200127 $108.99 1 52 L
Attention: Selena Serrano THE STATE OF TEXAS
CITY OF SOUTHLAKE 171.......X.316 . COUNTY OF TARRANT
1400 MAIN ST
STE 440 l Before me,a Notary Public in and for said County
SOUTHLAKE,TX 760927604 , �Yl t 0 1
a'f
hand State,this day personally appeared Amanda
Grisham,Bid and Legal Coordinator for the Star-
Telegram,published by the Star-Telegram,Inc.at
PUBLIC HEARING NOTICE Fort Worth,in Tarrant County,Texas;and who,
CITY OF SOUTHLAKE,TEXAS after beingdulysworn,did depose and saythat
Notice is hereby given to all interest- ) P
ed persons that the City of Southlake, . - the attached clipping of an advertisement was
•
T the,Couill ncil
ar eChambers atTfollowing items PUBLIC HEARING NOTICE' published in the above named paper on the listed
inthe Council l Town Hall,s CITY OF SOUTHLAK
E,Main Street, Southlake, Texas TEXAS
for: Notice is hereby given to'ell Interest- dates:
The City Council on Tuesday,April 19, ed persons that the City of Southlake,.
2022,at 5:30 p.m.will hold a public Texas,will consider the following items
•hearing and consider: in the Council Chambers at Town Hall, No.of Insertions: 1
Resolution No. 22-002,ZA21-0103, 1400 Main Street,'Southlake, Texas
Specific-Use Permit-for Electrical'Ve- for:
hide Charging Spaces on property The City Council on Tuesday,April 19,`, Beginning Issue of: 04/03/2022
described as Lot 1,Block 4,Gateway 2022,at 5:30 p.m.will hold a public
Church-114 Campus, City of South- hearing and consider: Ending Issue of: 04/03/2022
lake,Tarrant County,Texas and locat- Resolution No. 22-002,'ZA21-0103,
ed at 1200 E.SH 114,Southlake,Tex- Specific Use Permit for Electrical Ve-
as.Current Zoning:"S-P-1"Detailed hide Charging Spaces on property
Site Plan District.SPIN Neighborhood described as Lot 1,Block 4,Gateway 1
#4. Church-114 Campus; City of South-
Ordinance No. 1246, adopting the lake,Tarrant County,Texas and boat-.
2021 International Building Code. ed at 1200 E SH 114;Southlake,Tex-
Ordinance No. 1247, adopting the as. Current Zoning: "S-P-1," Detailed
2021 International Energy Conserve- Site Plan District.SPIN Neighborhood
tion Code. #4
Ordinance No. 1248, adopting the Ordinance No. 1246, adopting the
2021 International Fire Code. 2021 International Building Code.
Ordinance No. 1249, adopting the Ordinance No. 1247, adoptin
2021 International Mechanical Code. g the •
Ordinance No. 1250, adopting the 2021 International Energy Conserva-
2021 International Plumbing Code. tion Code. - ,
Ordinance No. 1251, adopting the 20Ordinance No. 1248,,adopting the
2021 International Fuel Gas Code. Ord 1 International
No.ocen Fire 1249,Code.adopting
1_ n
Ordinance No. 1252, adopting the Or g the k
2021 International Residential Code. 2021 International Mechanical Code.
Ordinance No. 1253, adopting the Ordinance No..1250, adopting the
2021 International Existing Building .2021 International Plumbing Code. Sworn to and subscribed before me this 4th day of April
Code. 021 Internainance tional Fuel Gas�Code.the year of 2022
Ordinance No. 1254, adopting thein the
2021 International Swimming Pool and Ordinance No. 1252, adopting the
Spa Code. •2021 International Residential Code.
Ordinance No. 1255, adopting the Ordinance No..1253, .adopting the
2021 International Property Mainte- 2021 International Existing Building •
nance Code. Code.
All interested persons are urged to Ordinance No. 1254, adopting the
attend. 2021 International Swimming Pool and
City of Southlake Spa Code.
Amy Shelley,TRMC Ordinance No. 1255, adopting the ���¢,�jy�,l/r/
City Secretary 2021 International Property Mainte- 546 .
(/
IPL0067379 nance Code. •
Apr 3 2022 •All interested persons are urged to
attend. Notary Public in and for the state of Texas,residing in
City of Southlake '
'Amy Shelley,TRMC Dallas County
City Secretary
IPL0067379 r g• r,...` �` "
Apr 3 2022 I? sl BEARD
f.iv�t :`jc. . *Not*ID101347 i II
, • %yij ey sh" E> Mite*23,2022
n - - - -
EExtra charge for lost or duplicate affidavits.
Legal document please do not destroy!