1251 2021 International Fuel Gas Code ORDINANCE NO. 1251 AN ORDINANCE ADOPTING THE INTERNATIONAL FUEL GAS CODE, 2021 EDITION, REGULATING THE INSTALLAION OF FUEL-GAS PIPING SYSTEMS, FUEL GAS APPLIANCES, GASEOUS HYDROGEN SYSTEM AND RELATED ACCESSORIES EXCEPT ONE- AND TWO-FAMILY DWELLINGS AND MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES) IN THE CITY OF SOUTHLAKE; PROVIDING FOR THE ADOPTION OF LOCAL AMENDMENTS THERETO; PROVIDING FOR RECORDING OF SUCH CODE AS A PUBLIC RECORD; PROVIDING THAT THIS ORDINANCE SHALL BE CUMULATIVE OF ALL ORDINANCES; PROVIDING A SEVERABILITY CLAUSE; PROVIDING A SAVINGS CLAUSE; PROVIDING FOR PUBLICATION IN PAMPHLET FORM; PROVIDING FOR PUBLICATION IN THE OFFICIAL NEWSPAPER; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, the City of Southlake, Texas is a home rule city acting under its charter adopted by the electorate pursuant to Article XI, Section 5 of the Texas Constitution and Chapter 9 of the Local Government Code; and WHEREAS, the City Council of the City of Southlake deems it necessary to adopt this ordinance governing requirements for the installation and maintenance fuel gas systems including requirements for materials, in order to protect the health, safety and welfare of the citizens of the City of Southlake. WHEREAS, beginning in the spring of 2021, NCTCOG's Regional Codes Coordinating Committee (RCCC) and its four advisory boards conducted open review meetings over a one-year period to review the 2021 editions of the International Codes and to develop regional amendments. Their review and recommendations were completed and endorsed by NCTCOG's Executive Board In July 2021. Now NCTCOG encourages jurisdictions in North Central Texas to adopt the 2021 International Fuel Gas Code along with its respective regional amendments: 2021 IFGC 1 NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS: Section 1 Adoption That the International Fuel Gas Code, 2021 Edition, published by the International Code Council, is hereby adopted as the Fuel Gas Code of the City of Southlake, except for fuel gas systems otherwise regulated under the International Residential Code for One- and Two- Family Dwellings as adopted. A True and correct copy of this document is referenced in Exhibit "A." Section 2 Amendments That the 2018 International Fuel Gas Code, as adopted herein, is hereby amended as provided in Exhibit "B" incorporated herein and attached hereto for all purposes of this ordinance. The City of Southlake may from time to time determine that additional local modifications to the 2021 International Fuel Gas Code are necessary and appropriate to meet the unique construction needs of the City of Southlake. To effectuate these modifications, the City council shall enact individual ordinances amending this ordinance fully setting forth the change to be made in the code. The amendments shall be consolidated as Exhibit "B" to this ordinance. Section 3 Recording The material contained in Exhibits "A" and "B" to this ordinance shall not be included in the formal municipal codification of ordinances but shall be maintained as a public record in the office of the City Secretary and/or the office of Building Inspections and will be available for public inspection and copying during regular business hours. Section 4 Cumulative Clause This ordinance shall be cumulative of all provisions of ordinances of the City of Southlake, Texas, except where the provisions of this ordinance are in direct conflict with the provisions of such ordinances, in which event the conflicting provisions of such ordinances are hereby repealed. Section 5 Severability It is hereby declared to be the intention of the City Council that the phrases, clauses, sentences, paragraphs and sections of this ordinance are severable, and if any phrase, clause, sentence, paragraph or section of this ordinance shall be declared unconstitutional by the valid judgment or decree of any court of competent jurisdiction, such unconstitutionality shall not affect any of the remaining phrases, clauses, sentences, paragraphs and sections of this ordinance, since the same would have been enacted by the City council without the incorporation in this ordinance of any such unconstitutional phrase, clause, sentence, paragraph or section. It is not the intention of this ordinance to conflict in any way with the Plumbing License Law of Texas. 2021 IFGC 2 Section 6 Penalty Any person, firm or corporation who violates, disobeys, omits, neglects or refuses to comply with or who resists the enforcement of any of the provisions of this ordinance shall be fined not more than Two Thousand Dollars ($2,000.00) for all violations involving zoning, fire safety or public health and sanitation, including dumping or refuse, and shall be fined not more than five hundred dollars ($500) for all other violations of this ordinance. Each day that a violation is permitted to exist shall constitute a separate offense. Section 7 Saving Clause All rights and remedies of the City of Southlake are expressly saved as to any and all violations of the provisions of any ordinances affecting the installation and maintenance of fuel gas systems which have accrued at the time of the effective date of this ordinance; and, as to such accrued violations and all pending litigation, both civil and criminal, whether pending in court or not, under such ordinances, same shall not be affected by this ordinance buy may be prosecuted until final disposition by the courts. Section 8 Publication The City Secretary of the City of Southlake is hereby authorized to publish this ordinance in book or pamphlet form for general distribution among the public, and the operative provisions of this ordinance as so published shall be admissible in evidence in all courts without further proof than the production thereof. The City Secretary of the City of Southlake is hereby directed to publish in the official newspaper of the City of Southlake, the caption, penalty clause, publication clause and effective date of this ordinance one time within ten days after passage of this ordinance, as required by Section 3.13 of the Charter of the City of Southlake. Section 10 Effective Dave This ordinance shall be in full force and effect from and after its passage and publication as required by law but not before May 1, 2022. 2021 IFGC 3 APPROVED ON FIRST READING THIS 5 DAY OF APRIL, 2022. MAYOR LA � �OJ. • ' •••, PrEST: ••.3Lr =o; v•• •' CITY SECRETARY Via'/"..„'• .... 0 \ 'kw lio0" APPROVED ON SECOND READING THIS 19 DAY OF APRIL, 2022. (WhAr-24,7 -c�LA/fp�°°° MAYOR 0 1 N ATTEST: "\ sip 0® .\ ®s°°° *o `,�000 N""Nio CITY SECRETARY APPROVED AS TO FORM AND LEGALITY: ecteg_,Jizfr CITY ATTORNEY PUBLISHED: Li 193)29, EFFECTIVE: cp51 , 2021 IFGC 4 EXHIBIT A 2021 International Fuel Gas Code Complete Edition Located in the Building Inspections Office 1400 Main St., Suite 250 City of Southlake, Texas 76092 2021 IFGC 5 EXHIBIT B Amendments to the 2021 International Fuel Gas Code The following sections, paragraphs, and sentences of the 2021 International Fuel Gas Code are hereby amended as follows: Standard type is text from the IFGC. Underlined type is text inserted. Lined through type is deleted text from IFGC. A double asterisk (**) at the beginning of a section identifies an amendment carried over from the 2018 edition of the code and a triple asterisk (***) identifies a new or revised amendment with the 2021 code. **Section IA1102.2;add an exception to read as follows: Exception: Existing dwelling units shall comply with Section 621.2. (Reason: Previous code provisions made unvented heater provisions retroactive except as provided for in local amendment. This amendment and amendment to IFGC 621.2 better clarify what the code already states:existing systems ma sta unless considered unsafe.) **Section 102.8;amend and add to read as follows: [A]102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 15 and such codes, when specifically adopted, and standards shall be considered as part of the requirements of this code ... {Remainder Text unchanged} JA1102.8.3 Local amendments.Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the adopted amendments. Any reference to NFPA 70 or the National Electrical Code (NEC) shall mean the Electrical Code as adopted. (Reason: To recognize local) ado•ted codes and amendments ado•ted with referenced codes.) **Section 306.3;change to read as follows: [M] 306.3 Appliances in attics. Attics containing appliances shall be provided . . . {bulk of paragraph unchanged} . . . As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull down stair with a minimum 300 lb. (136 kg) capacity. 3. An access door from an upper floor level. 4. Access Panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due to building conditions. Exceptions: 1. The passageway ... 2. Where the passageway is unobstructed and not less than 6 feet (1829 mm) high and 22 inches (559 mm)wide for its entire length....{bulk of section to read the same}. (Reason: To provide a safe means of accessibility to appliances in attics and to allow for different types of construction limitations. Consistent with regional amendment to IMC 306.3. Exception to match IMC 306.3#2) **Section 306.5;change to read as follows: 2021 IFGC 6 [M] 306.5 Equipment and appliances on roofs or elevated structures. Where equipment requiring access or appliances are located on an elevated structure or the roof of a building such that personnel will • have to climb higher than 16 feet (4877 mm) above grade to access, an interior or exterior means of access shall be provided. Exterior ladders providing roof access need not extend closer than 12 feet (2438 mm) to the finish grade or floor level below and shall extend to the equipment and appliances' level service space. Such access shall . . . {bulk of section to read the same} . . . on roofs having a slope greater than four units vertical in 12 units horizontal (33-percent slope). ... {remainder of text unchanged}. (Reason: To assure safe access to roof appliances Consistent with IMC amendments.) **Section 306.5.1; change to read as follows: [M] 306.5.1 Sloped Roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of 3 units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code (Reason: To assure safe access to roof appliances. Consistent with IMC amendments.) **Section 401.5;Identification. add a second paragraph to read as follows: Both ends of each section of medium pressure gas piping shall identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING 1/2 to 5 psi gas pressure Do Not Remove" (Reason: To protect homeowners and lumbers.) .J4Q`.a �29l k `..�.�^ �'f^i'r�itix; w��.++�n "�k,�'ty'r_°�fYe:�C:�SY n r. c3 , �.:� �.;. .. . c t t`+ s C,.' 'Y5!+,��n,e;rn^`�. , ' pt: ,Jr � . ,'P. **Section 404.12 and 404.12.1; change to read as follows: 404.12 Minimum burial depth. Underground piping systems shall be installed a minimum depth of 42 18 inches (305 458 mm) top of pipe below grade, gxccpt as provided for in Section 104.12.1. 404.12.1 Individual Outdoor Appliances;Delete in its entirety (Reason: To provide increased protection to piping systems and address reference number change. Corres onds with IRC G2415.12) ...«. .. ,. ,',' ': `w� ""�"`Y sc:,;,:�..'ys. ., • - .>,`�",L,L.: r..,,r`}.`i�'` ,:d.6- :v6'' r ,. ***Section 406.4; change to read as follows: 406.4 Test pressure measurement. Test pressure shall be measured with a monometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure. Spring type gauges do not meet the requirement of a calibrated gauge. (Reason: To require the use of more accurate diaphragm gauges. Spring gauges do not provide accurate measurement below ap.roximatel 17 psig) **Section 406.4.1;change to read as follows: 2021 IFGC 7 406.4.1 Test pressure. The test pressure to be used shall be no less than 1 1/2 times the proposed maximum working pressure, but no lees than 3 psig (20 kPa gauge), or at the discretion of the Code Official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge. irrespective of design pressure. Where-the-test-pressure For tests requiring a pressure of 3 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one half inches (3 1/2'), a set hand, 1/10 pound incrementation and pressure range not to exceed 6 psi for tests requiring a pressure of 3 psig. For tests requiring a pressure of 10 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3 '/2"), a set hand, a minimum of 2/10 pound incrementation and a pressure range not to exceed 20 psi. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (1/2 psi) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Diaphragm gauges used for testing must display a current calibration and be in good working condition. The appropriate test must be applied to the diaphragm gauge used for testing. (Reason: To provide for lesser pressures to coordinate with the use of more accurate diaphragm gauges. Corresponds to IRCG 2417.4.1) **Section 409.1;add Section 409.1.4 to read as follows: 409.1.4 Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings, and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping. (Reason: To provide proper security to CSST valves. These standards were established in this region in 1999 when CSST was an emerging technology. Corresponds with IRC G2420.1.4) **Section 410.1;Add a second paragraph and exception to read as follows: 410.1 Pressure regulators. A line pressure regulator shall be ... {bulk of paragraph unchanged}... approved for outdoor installation. Access to regulators shall comply with the requirements for access to appliances as specified in Section 306. Exception: A passageway or level service space is not required when the regulator is capable of being serviced and removed through the required attic opening. (Reason: To require adequate access to regulators. Corresponds with IRC G2421.1) **Section 411.1.3.3;Prohibited locations and penetrations. Delete Exception 1 and Exception 4. (Reason: To comply with accepted regional practices. Corresponds with IRC G2422.1.2.3) ,621.2 **Section 621.2;add exception as follows: 621.2 Prohibited use. One or more unvented room heaters shall not be used as the sole source of comfort heating in a dwelling unit. Exception: Existing approved unvented heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the Code Official unless an unsafe condition is determined to exist as described in Section 108.7. (Reason: Gives code official discretion. Corresponds with IRC G2445.2) 2021 IFGC 8 **Section 624.1.1;add to read as follows: 624.1.1 Installation requirements. The requirements for water heaters relative to sizing...{bulk of paragraph unchanged)...with the International Plumbing Code. The requirements for water heaters relative to access, sizing, relief valves, drain pans and scald protection shall be in accordance with this code. (Reason: To clarify installation requirements. Also corresponds with amendments regarding water heater access. Corresponds to IRC G2448.1.1) END 2021 IFGC 9 Beaufort Gazette The Herald-Rock Hill el Nuevo Herald-Miami Sun News-Myrtle Beach Belleville News-Democrat Herald Sun Durham Modesto Bee The News Tribune Tacoma Bellingham Herald Idaho Statesman Raleigh News&Observer The Telegraph-Macon Bradenton Herald Island Packet The Olympian San Luis Obispo Tribune J NMCCLATCHY Centre Daily Times Kansas City Star Sacramento Bee Tri-City Herald Charlotte Observer Lexington Herald-Leader Fort Worth Star-Telegram Wichita Eagle Columbus Ledger-Enquirer Merced Sun-Star The State-Columbia. Fresno Bee Miami Herald Sun'Herald-Biloxi Page 1 of 1 CITY OF SOUTHLAKE MEMO INVOICE. 1400 MAIN ST STE 440 Order No.: 242377 SOUTHLAKE TX 760927604 Memo Date: 04/04/2022 Bill-To Account: 36037 Sales Rep: Haley Martin Dates Order No. Description Product Size Billed Times Net Amount Unit Run 04/03/2022-04/03/2022 242377 Print Legal Ad FTW-Star-Telegram 1 x 52 L 52 L 1 $108.99 IPL0067379 Legal I Legals&Public Notices CLS P0:22200127 016 No : vo2q(0 1261 rov it-52 ,��. 1 ) 01A 1 ItI 9 1 511 I-2) 50 i256- Please Return This Portion With Your Payment(Thank You) MEMO INVOICE McClatchy Company LLC Order No.: 242377 PO Box 510150 Account No.: 36037 Livonia MI 48151 Account Name: CITY OF SOUTHLAKE Order Amount: $108.99 *** MEMO INVOICE *** Email questions to ssccreditandcollections@mcclatchy.com CITY OF SOUTHLAKE 1400 MAIN ST McClatchy Company LLC STE 440 PO Box 510150 SOUTHLAKE TX 760927604 Livonia MI 48151 Beaufort Gazette The.Herald-Pock Hill el Nuevo Herald-Miami Sun News-Myrtle Beach Belleville News-Democrat Herald Sun-Durham Modesto Bee The NeWS Tribune Tacoma Bellingham Herald Idaho Statesman Raleigh News&Observer The Telegraph-Macon Bradenton Herald Island Packet The Olympian San Luis Obispo Tribune . it\MCCL,ATCHY Centre Daily Times Kansas City Star Sacramento Bee Tri-City Herald Charlotte Observer Lexington Herald-Leader Fort Worth Star-Telegram Wichita Eagle Columbus Ledger-Enquirer Merced Sun-Star The State-Columbia Fresno Bee Miami Herald Sun Herald-Biloxi AFFIDAVIT OF PUBLICATION Account# Order Number Identification Order PO Amount Cols Depth 36037 242377 Print Legal Ad-IPL0067379 22200127 $108.99 1 52 L Attention: Selena Serrano THE STATE OF TEXAS CITY OF SOUTHLAKE11111!.....,0)11:...„ COUNTY OF TARRANT 1400 MAIN ST STE 440 l Before me,a Notary Public in and for said County SOUTHLAKE,TX 760927604 �1 �� ` and State,this day personally appeared Amanda /f ill 1 GrishamBidandLegalCoordinatorfortheStara Telegram,published by the Star-Telegram,Inc.at PUBLIC HEARING NOTICE Fort Worth,in Tarrant County,Texas;and who, CITY OF SOUTHLAKE,TEXAS after beingdulysworn,did depose and saythat Notice is hereby given to all interest- p ed persons that the City of Southlake, the attached clipping of an advertisement was Texas,the Co nccilhar beChambersatTfollowing items PUBLIC HEARING NOTICE published in the above named paper on the listed inthe Council lake.Texas . CITY OF•SOUTHLAKE 1400 Main Street, Southlake, ,TEXAS for: Notice is hereby given teal!interest- dates: The City Council on Tuesday,April 19, ed persons that the City of Southlake,. 2022,at 5:30 p.m.will hold a public Texas,will consider the following items r hearing and consider: _ in the Council,Chambers at Town Hall, No.of Insertions: 1 Resolution o. 22-0027 ZA21-0103) 1400 Main Street,'Southlake, Texas Specific Use-Permit'forElectricarVe- for: hide Charging Spaces on property The City Council on Tuesday,April 19,` Beginning Issue of: 04/03/2022 described as Lot 1,Block 4,Gateway 2022,at 5:30 p.m.will hold a public `, Church-114 Campus, City of South- hearing and consider: • Ending Issue of: 04/03/2022 lake,Tarrant County,Texas and local- Resolution No. 22-002, ZA21-0103, ed at 1200 E.SH 114,Southlake,Tex- Specific Use Permit for Electrical Ve- as.Current Zoning:"S-P-1"Detailed hide Charging Spaces on property Site Plan District.SPIN Neighborhood described as Lot 1;Block 4,Gateway 1 #4. Church-114 Campus; City of South- Ordinance No. 1246, adopting the lake,Tarrant County,Texas and locat- 2021 International Building Code. ed at 1200E SH 114;Southlake,Tex- Ordinance No. 1247, adopting the as. Current Zoning: "S-P-1."Detailed 2021 International Energy Conserve- Site Plan District.SPIN Neighborhood tion Code. #4. Ordinance No. 1248, adopting the Ordinance No. 1246, adopting the 2021 International Fire Code. 2021 International Building Code. Ordinance No. 1249, adopting the Ordinance No. 1247, ado tin the 2021 International Mechanical Code. 2021 International Energy Conserve- ' Ordinance No. 1250, adopting the tion Code. 2021 International Plumbing Code. Ordinance No. 1248, • adopting Ordinance No. 1251,l Fuel adopting the . g the (k--) 2021 International Fuel Gas Code. Ordinance International Fire Code. Ordinance No. 1252, adopting the No. 1249, adopting the 2021 International Residential Code. 2021 International Mechanical Code. , Ordinance No. 1253, adopting the Ordinance No..1250, adopting the 2021 International Existing Building 2021 International Plumbing Code. Sworn to and subscribed before me this 4th day of April Code. Ordinance No: 1251, adopting the Ordinance No. 1254, adopting the •2021 International Fuel Gas Code. in the year of 2022 2021 International Swimming Pool and Ordinance No. 1252, adopting the Spa Code. 2021 International Residential Code. Ordinance No. 1255, adopting the Ordinance No._1253, adopting the 2021 International Property Mainte- 2021 International Existing Building nance Code. Code. All interested persons are urged to Ordinance No. 1254, adopting the attend. 2021 International Swimming Pool and City of Southlake Spa Code. �� . ���C� Amy Shelley,TRMC ,Ordinance No. .1255, adopting the 7�i,((r‘e City Secretary 2021 International Properly Mainte- IPL0067379 nance Code. , Apr 32022 •All interested persons.are urged to attend. Notary Public in and for the state of Texas,residing in City of Southlake • 'Amy Shelley,TRMC Dallas County City Secretary IPL0067379. • ' ' `�' f`" Apr 3 2022 S°7 { €�'� k. `" MI/Way ION 13i ,m 61;' . `1311 � F.> eo Oct ter 13,2022 • Extra charge for lost or duplicate affidavits. Legal document please do not destroy!