Loading...
Item 6L - PlansL. IN NEW DIRECTIONAL SIGN NEW BOLLARD, TYP. 7 - - 1/4" GALV. STEEL PLATE 7 A1.0 CAP, CONTINUOUS WELD GRIND SMOOTH Al A — ------ ---- FASTENER GALV. STEEL -UBE, PAINTED L TOP OF FOO FOR DRAINAG =1NISH GRADE DIA. CONCRE' DTING (3,000 P - 1/4" LIME GREEN BOLLARD COVER BY IDEALSHIELD.COM - 5" DIA. 36" HIGH HIDDEN BASE BOLLARD BY IDEALSHIELD.COM EXISTING PAVING i STEELTUBE SUPPORT ALUMINUM PARKING SIGN FASTENER SPACER Ile lie 11 SIGN DETAIL 7 SCALE: 3" = V-0" A1.0 1 1/4" GALV. STEEL PLATE — CAP, CONTINUOUS WELD GRIND SMOOTH FASTENERS 12"x18" ACCESSIBLE PARKING SIGN 0.63 ALUMINUM, REFLECTIVE WHITE LINES AND LETTERING ON REFLECTIVE BLUE FIELD. MATCH EXISTING SIGN PENALTY SIGN IN 1" - LETTERS (MIN.) GALV. STEEL TUBE, PAINTED. MATCH EXISTING POST HEIGHT BEVEL TOP OF FOOTING 1" FOR DRAINAGE FINISH GRADE -- 10" DIA. CONCRETE - FOOTING (3,000 PSI) NEW HC PARKING SIGN. SEE DETAIL 5/A1.0 NEW 5" DIA. 36" HIGH HIDDEN BASE BOLLARD. SEE DETAIL 4/A1.10. TYP. OF (2)/� NEW HC PARKING SIGN.��y SEE DETAIL 5/A1.0 WHEEL STOP, - -- _ PAINTED TO MATCH BOLLARDS, TYP. / NEW SURFACE MOUNTED FIRE EXTINGUISHER TYPE 2-A:20-B:C AUUtzbbIbLt UNAKUNU 5 I A I IUN bHALL UUIVINLY WITH TAS 309 AND SHALL BE WITHIN THE FORWARD REACH RANGES SPECIFIED IN TAS 308.2 PARTIAL ELEVATION 8 SCALE: 1/8" = V-0" A1.0 NEW 5" DIA. 36" HIGH HIDDEN BASE BOLLARD. SEE DETAIL 4/A1.0 TYP. OF (5) NEW CAR CHARGING STATION, TYPICAL (5) ACCESSIBLE CAR CHARGING STATION. CONTROLS AND OPERATING MECHANISMS FOR THE ACCESSIBLE CHARGING STATION SHALL COMPLY WITH TAS 309 AND SHALL BE WITHIN THE FORWARD REACH j RANGES SPECIFIED IN TAS 308.2 �.J NEW HC PARKING SIGN - NEW DIRECTIONAL SIGN II I I I I I I I I I I I I I I I I I I � I I I I I I I I I I I I � I I � I 17 — — — — — — - — —u— 24'FIRELANE --- I I � I � II W Z J W Q CD ' NJ.9r 748Q� FOFl FIRM REGISTRATION #: BR 301 14 MARCH 2O22 DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS, PREPARED BY OXLEY WILLIAMS THARP ARCHITECTS, PLLC ARE INSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT. THIS INCLUDES DOCUMENTS IN ELECTRONIC FORM. OXLEY WILLIAMS THARP ARCHITECTS, PLLC SHALL BE DEEMED THE AUTHORS AND OWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICE AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS. THE INSTRUMENTS OF SERVICE SHALL NOT BE USED BY THE OWNER FOR FUTURE ADDITIONS OR ALTERATIONS TO THIS PROJECT OR FOR OTHER PROJECTS, WITHOUT THE PRIOR WRITTEN AGREEMENT OF OXLEY WILLIAMS THARP ARCHITECTS, PLLC. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF SERVICE SHALL BE WITHOUT LIABILITY TO OXLEY WILLIAMS THARP ARCHITECTS, PLLC AND ITS CONSULTANTS. Revision Schedule Rev. Revision Revision # Description Date 1 City Comments 03-14-2022 CONSTRUCTION DOCUMENTS OW T ARCHITECTS 509 PECAN STREET SUITE 100 FORT WORTH, TX 76102 817.993.9844 www.owtarchitects.com WESTI N HOTEL SOUTHLAKE 1200 E. STATE HWY 1141 SOUTH LAKE, TX 76092 2014-001-00 24 FEBRUARY, 2022 NOTE:CAR CHARGING STATIONS SHALL BE CENTERED WITH PARKING STRIPE. TOTAL PARKING SPACES - 424 SPACES NUMBER OF CHARGING STATIONS - 12 SPACES, 2.8% CHARGING ---- STATIONS ENLARGED SITE PLAN — NORTH CAR CHARGING STATIONS 3 CAR CHARGING STATION 2 SITE PLAN - CAR CHARGING STATIONS 1 SCALE: 3/32" = V-0" A1.0 NOT TO SCALE A1.0 SCALE: 1" = 30'-0" A1.0 Al - —A Al 1 a ■ ZA21-0103 or— _A616- inu�lllllp� ok ;� �1 ili lilil�l�l 'il� 1111 lilllllill ili IIII II�II�IIII (I)I "'' IU r _ M I.r 3-14-2022 WESTIN SOUTHLAKE PROPOSED CAR CHARGING STATIONS OWT ARCHITECTS ZA21-0103 I ■ DUAL PORT 30A LEVEL 2 ■ CHARGING PROTOCOL: SAE J-1772 ■ 7.2 KW PER PORT ■ NEMA 313 HOUSING ■ OCPP COMPLIANT ■ 7" COLOR SCREEN ■ UL COMPLIANT—ETL CERTIFIED ■ OPTIONS • CABLE RETRACTOR DUAL PORT 30A AMP LEVEL 2 COMMERCIAL CHARGING STATION PEDESTAL Model # EVP-2002-30 Power per Port 7.2 kW (240V AC @ 30A) Electrical Service Power 240/208 VAC, 30A Load with 40A Branch Circuit Per Port Service Panel 40A Dual Breakers Per Port (No GFCI) Service Wiring 3-wire (1-1, 1-2, Earth Ground) Functional Interfaces Connector Type SAEJ1772 Charging Protocol SAE J1772 Standard Cable Length >18 ft Cable Retractor (option) Counter Weight Overhead Retractor ADA compliant LCD Display 1500 nits 7" color, 800 x 480, UV protected Card Reader ISO 14443 Type A&B, ISO 18092 NFC Vehicle to Grid (option) ISO 15118 (available June 2018) Safety and Connectivity Ground Fault Detection 5mA CCID trip with 3 x automatic restarts Detect Coupler Removal Per SAE J1772'" Power Measurement Accuracy: + 2% from 5% to full scale (30A) Power Report Interval Every 15 minute on the hour LAN (Optional) 2.4 GHz Wi-Fi (802.11 b/g/n) Wide Area Network 3G/4G GSM, 3G/4G CDMA Communication Protocols OCPP 1.5, OCPP 1.6 Safety and Operation Enclosure Rating NEMA 3R Regulatory Compliance ETL certified for USA and cUL certified for Canada; complies with UL 2594, UL 2231-1, UL 2231-2, and NEC Article 625, EMC: FCC Part 15 Class A Surge Protection 6KV @ 3000A Operating Temperature -30°C to +50°C (-22°F to 122°F) Storage Temperature -30°C to +50'C (-22'F to 122°F) Altitude 6000 ft Humidity 85% non condensing • CREDIT CARD SCANNER • 3G/4G GPRS Modem • V2G per ISO 15118 (June 2018) CP0VVEERWWW.BTCP0WER.00M ZA21-0103 1719 GRAND AVE, SANTA ANA, CA 92705 BTCPowrk--R User Manual & Installation Instructions Q Note: Display and Retractable Assemblies are Optional Credit Card Reader Can Be RFID or Both (RFID & Credit Card Reader) EVP-1001-XX EVP-1002-XX EVP-2001-XX EVP-2002-XX Part Number Description EVP-1001-00 30 Amp Installation EVP-1001-40 40 Amp Installation EVP-1001-70 70 Amp Installation EVP-2001-30 30 Amp Installation EVP-2001-40 40 Amp Installation EVP-2001-70 70 Amp Installation EVP-2002-30 30 Amp Installation EVP-2002-40 40 Amp Installation EVP-2002-30 30 Amp Installation EVP-2002-40 40 Amp Installation This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 1 1 P a g e BTCPowrk--R User Manual & Installation Instructions REVISION HISTORY Rev Date ECN # Description of BTC Power EVSE Engineer C 3/2/2013 1001 Initial Release Cortes D 4/10/2013 1002 Added warnings per ETL Hymel E 4/12/2013 1003 Added user instructions Schulz F 5/13/2013 1004 Added WiFi modem/ Level 2 without meter Hymel G 11/20/2014 1005 Updated to new hardware Paryani H 11/02/2015 1009, 1006 Updated hardware as well as payment controller Cortes 1 1/5/2017 Added updated charger images Moinee J 3/22/2017 Updated Entire Manual Elmassry K 8/9/17 Updated Entire Manual. Add Spec Dwgs. Elmassry L 10/9/17 Updated Entire Manual. Added Troubleshooting and Warranty Information. Elmassry M 11/10/17 Updated I -sheets Elmassry N 6/5/18 Added Display and WiFi Instructions Elmassry O 6/18/2018 Service Breaker requirements Moinee This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 2 1 P a g e BTCP�� User Manual & Installation Instructions PLEASE NOTE This user's manual includes the latest information at the time of printing. BTC Power, Inc. (BTC Power) reserves the right to make changes to this product without further notice. Changes or modifications to this product by other than an authorized service facility could void the product warranty. If you have questions about the use of this product, contact your customer service representative. Refer to the Customer Support section located in this guide. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 3 1 P a g e BTCPov�� Table of Contents User Manual & Installation Instructions 1 IMPORTANT SAFETY INSTRUCTIONS............................................................................................5 1.1 Safety Guidelines.............................................................................................................................5 1.2 GROUNDING INSTRUCTIONS....................................................................................................7 2 INSTALLATION...................................................................................................................................... 8 2.1 Before Installing...............................................................................................................................8 2.2 Safety Requirements.......................................................................................................................8 2.3 Tools and Ancillary Equipment......................................................................................................9 2.4 Special Tools & Hardware Torque Value...................................................................................10 2.5 Installation Procedure for Pedestal Chargers...........................................................................11 2.6 Installation Procedure for Wall Mounted EVSE Chargers.......................................................14 3 ELECTRICAL CONNECTIONS.........................................................................................................16 3.1 EVP-30 Single and dual charge system electrical connection...............................................16 3.2 Single Port EVSE Charger..........................................................................................................17 3.3 Dual Port EVSE Charger..............................................................................................................18 4 Operation................................................................................................................................................20 4.1 Screen Scenarios......................................................................................................................... 20 4.2 WIFI Network..................................................................................................................................23 5 TESTING................................................................................................................................................26 6 TROUBLESHOOTING........................................................................................................................27 7 SPECIFICATIONS...............................................................................................................................28 7.1 DUAL PEDESTAL GENERAL DIMENSIONS...........................................................................29 7.2 SINGLE PEDESTAL GENERAL DIMENSIONS.......................................................................30 7.3 DUAL WALL MOUNT GENERAL DIMENSIONS.....................................................................31 7.4 SINGLE WALL MOUNT GENERAL DIMENSIONS.................................................................33 This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 4 1 r a g e BTCPowrk--R User Manual & Installation Instructions 1 IMPORTANT SAFETY INSTRUCTIONS 1.1 Safety Guidelines WARNING READ THIS MANUAL BEFORE YOU BEGIN EVSE (Electric Vehicle Supply Equipment) manages electricity and may be hazardous. Failure to follow the below precautions and the Danger, Warning and Caution instructions in this manual may result in serious injury. Follow all rules, codes and laws that apply to your area and installation guidelines. IMPORTANT SAFETY INSTRUCTIONS The following symbols may be found in your handbook or on labels affixed to your conductive charge station: DANGER Danger indicates a hazard or unsafe practice which, if not avoided, will result in severe injury or possibly rionth !AnotWARNING Warning indicates a hazard or unsafe practice which, if avoided, may result in severe injury or possibly death. IN- CAUTION Caution indicates a hazard or unsafe practice which, if not avoided, may result in minor injury Important information to consider, otherwise, improper NOTE: installation and/or damage to components may occur. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 5 1 P a g e BTCPowER SAFETY GUIDELINES User Manual & Installation Instructions Use this charge station to charge electric vehicles equipped with an SAE J1772 charge port connector only. To determine if your vehicle is equipped with one please review the vehicle owner handbook. When installing the equipment and during regular operation please ensure the charge station's supply cable is located in such a way that the cable will not be tripped over, stepped on, pulled from the wall socket, or somehow subjected to damage or stress during normal operation or while stored. Read all the instructions before using this product. This device should be supervised when used around children Do not put fingers into the electric vehicle connector Do not use this product if the flexible power cord or EV cable is frayed, has broken insulation or other signs of damage Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows other indication of damage SAVE THESE INSTRUCTIONS This manual contains important instructions for Models 30A,40A, and 70A Pedestal, wall mount, in single and dual configurations. WARNING • If your supply cable is somehow damaged do not operate your charge station. Contact your service representative for service immediately. Shut down the power to the unit by switching the breaker on the supply panel to the off position. • Turn off input power to your charge station at the circuit breaker panel before servicing or cleaning the unit. • VENTILATION: Some electric vehicles require an external ventilation system to prevent the accumulation of hazardous or explosive gases when charging indoors. Check the vehicle's owner's handbook to determine if your vehicle requires ventilation during indoor charging. • Those vehicles which follow the SAE J1772 standard for communication with the charging station can inform the EVP EVSE that they require an exhaust fan. The EVP EVSE is not equipped to control ventilation fans. • This device utilizes high voltages do not attempt to install this equipment if you are not a qualified electrician. • There are no user serviceable parts inside. For service please contact customer service or your local distributor. DO NOT ATTEMPT TO REPAIR THE CHARGE STATION YOURSELF ONLY FACTORY QUALIFIED PERSONEL. CAUTION Do not charge your vehicle indoors if it requires ventilation. Contact your service representative for information. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 6 1 P a g e BTCPowrk--R User Manual & Installation Instructions Please refer to local municipalities for Electrical, structural and mechanical engineering relating to the installation of this L2 commercial charging station. 1.2 GROUNDING INSTRUCTIONS This product must be connected to a grounded, metal, permanent wiring system, or an equipment -grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the product. This device shall be mounted at a sufficient height from grade such that the height of the storage means for the coupling device is located between 600 mm (24 inches) and 1.2 m (4 feet) from grade 120/240 VAC, 10 BONDED NEUTRAL L2 120 VAC 120 VAC 1GND STATION IS CONNECTED TO Li AND L2. NEUTRAL IS NOT USED. 120/208 VAC, 30 WYE BONDED NEUTRAL L3 1 �20111 VAC 1 L2 ]208 VAC 1 208 VAC 1 GND L1 20 VAC +NEU„ NC STATION MAY BE CONNECTED TO ANY TWO LINES. NEUTRAL IS NOT USED. 120/240 VAC, 30 DELTA CENTER TAP GROUNDED BONDED NEUTRAL L3 (HIGH LEG) NC DO NOT CONNECT ANY PART OF THE SYSTEM TO THIS POINT. L2 tl 1, za vnC } NEU TGD ( 240 VAC 120IVAC NC , 240 VAC J L1 STATION MUST BE CONNECTED TO L1 AND L2 ONLY. DO NOT CONNECT ANY PART OF THE SYSTEM TO L3 (HIGH LEG). Do not connect to these systems Do not connect ChargePoint stations to the following types of power sources: 120/208 VAC 3 phase wye, ungrounded 120/240 VAC 3 phase delta, corner -grounded Any system where the center point of the AC power source is not grounded 208 VAC, 30 WYE FLOATING NEUTRAL 120/240 VAC, 30 DELTA CORNER GROUNDED VAC VOLTAGE OF EITHER LINE TO VOLTAGE OF ANY LINE IS NOT 120V GROUND IS UNDETERMINED. NOMINAL RELATIVE TO GROUND. NEUTRAL IS NOT GROUNDED. BTCPowrk--R 2 INSTALLATION 2.1 Before Installing User Manual & Installation Instructions Before any installation work is performed, study all drawings furnished by the supplier for the particular installation. These include arrangement drawings (front, end, and plan views), connections to the equipment that may be required to meet any local codes (such as mats, screens, or railings) is not furnished. 2.2 Safety Requirements The EVSE (Electric vehicle supply equipment) should be installed by a qualified electrician in accordance with local codes and all applicable ordinances The charging station is required to be connected to a ground, metal, permanent wiring system. Connections to the charge station should comply with all local codes and ordinances. Read all installations instructions carefully prior to performing the installation. Safety Equipment included with EVSE BTCP EVSE's are equipped with a ground fault current interrupting device for user protection. The GFCI is automatically software tested so no user interaction is required to verify proper operation. In the event of a failure, the system will indicate a fault via a red LED or a message on the User Interface screen indicating an error code. DO NOT PROVIDE GFCI AT THE PANEL AS THE UNIT HAS A BUILT IN GFCI. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 8 1 P a g e BTCPowrk--R 2.3 Tools and Ancillary Equipment '/4" Lag Bolt QTY 6 1/4" Torque Wrench User Manual & Installation Instructions Concrete Expansion Bolts QTY 4 (f) 1/4" Washer QTY 6 3/16" Allen Wrench Phillips Screw Driver E)225 Back Door Key Instruction Manual This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 9 1 P a g e BTCPowrk--R 2.4 Special Tools & Hardware Torque Value User Manual & Installation Instructions Tools/Hardware Torque Specification Configuration 6-32 UNC 13 in-Ibs. +/- 2 in-Ibs. 10-32 UNF 30 in-Ibs. +/- 5 in-Ibs. 1/4-20 UNC 53 in-Ibs. +/- 7 in-Ibs. 1/2-13 UNC 48 in-Ibs. +/- 7 in-Ibs. M6 x 1 LIGUIDTIGHT FITTING 30 in-Ibs. +/- 5 in-Ibs. FUSE BLOCK LUGS, 8 AWG 40 in-Ibs. +/- 5 in-Ibs. FUSE BLOCK LUGS, 6 AWG 45 in-Ibs. +/- 5 in-Ibs. GROUND TERM. SCREWS, 14-10 AWG 34 in-Ibs. +/- 5 in-Ibs. GROUND TERM. SCREWS, 8 AWG 38 in-Ibs. +/- 5 in-Ibs. '/4-20" LOCKNUT 12 ft-Ibs. EVP-2001-XX-P EVP-2002-XX-P This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 10 1 P a g e BTCPowrk--R 2.5 Installation Procedure for Pedestal Chargers User Manual & Installation Instructions To mount dual and single Pedestal Chargers follow these steps: 1. Remove Pedestal Charger from Packaging 2. Open rear door assembly to expose nuts Remove rear door assembly so you can expose the nuts needed to release the enclosure from the Pedestal Base. Pedestal MUST be installed on a IT 4" Concrete Slab per Local Code. 3. Remove Qty 4 Nuts to release Pedestal from EVSE Charger Unit Note: Before bolting Pedestal Base to Concrete Slab, ensure that AC Powerlines are properly placed inside of conduit in the center of the pedestal base mounting location Relative Location for 1" Conduit =; �-' A A bib �W im This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 111 Page BTCPowrk--R 1 INCH CONDUIT Center of Conduit User Manual & Installation Instructions INVY61 4. After freeing Pedestal Base from EVSE Charger Unit, use concrete expansion bolts to bolt pedestal base to concrete slab. Qty 4 expansion bolts. Use pedestal base as a drill template Use Pedestal Base as a Drill Template 5. After bolting pedestal base to concrete, attached EVSE Charger by using the nut that was previously removed in step 3 to attached EVSE Charger to Pedestal Base. 6. Fasten Locknuts to 12ft-lbs as shown in figure below This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 12 1 P a g e BTCPowrk--R User Manual & Installation Instructions Bolt Qty 4'/4-20 nuts. Secure tightly onto chassis (12 ft-lbs) Power entry from Bottom of Enclosure is a 3" Square. a qWW , eAAP"' Note: Before bolting Pedestal Base to Concrete Slab, ensure that AC Powerlines are properly placed inside of conduit in the center of the pedestal base mounting location. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev 0 Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 13 1 P a g e BTCPowrk--R User Manual & Installation Instructions 2.6 Installation Procedure for Wall Mounted EVSE Chargers To mount the dual and single wall mount chargers, follow these steps: 1. Remove EVSE Wall Charger from packaging. 2. Locate key in same packaging to open charger exposing four mounting holes shown in the figure below. iog 3. Mount and secure rear EVSE hold bracket as shown in fig 8. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 14 1 P a g e BTCPowrk--R User Manual & Installation Instructions 4. Use expansion bolts to anchor the EVSE Wall Mount Charger to the wall as shown below for the Dual and Single EVSE Wall Mount Chargers. Use Level to Install Wall Mount BOX LEVEL f` F This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 15 1 P a g e BTCP�I� User Manual & Installation Instructions 3 ELECTRICAL CONNECTIONS The (wall mount) is provisioned to receive an electrical power connection from the bottom of the pedestal as shown in Fig. 11 AC input here Conduit hole opening is 1" dia. Recommended to enlarge Hole Opening Fig. 10 Electrical conduit bottom entry onto enclosure Power entry into assembly from bottom as shown here UL Listed water tight conduit entry fitting used at conduit / chassis interface Lower Door Opening: Terminal Block Location: Use Allen Wrench to Torque down Cables WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer's responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. 3.1 BTCPower Single and dual charge system electrical connection System electrical power needs to be provisioned with the following: Single sided charger connections • 2 appropriately gauged hot leads (typically 10 AWG for 30A installs and 8 AWG for 40A installs) 1 appropriately gauge ground (green) lead Install electrical conduit per all applicable state and federal regulations This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 161 Page BTCP�� User Manual & Installation Instructions • EVSE power should be inserted thru bottom of EVSE enclosure • Electrical connections shall be made as shown • Note, for the dual units, two separate line pairs need to be connected from independent service panel breakers of the appropriate rating. Note: Each hot lead should measure 120VAC to ground. Service Connections Electrical Input SINGLE PORT DUAL PORT AC Voltage 208/240VAC 208/240VAC Current Input Power Connection Required Service Current Input Power Connection Required Service Panel Breaker Panel Breaker 40A dual pole Two independent 40A branch 40A dual pole Standard 30A One 40A branch circuit (non-GFCI type) 30A x 2 circuits (non-GFCI type) x 2 40A One 50A branch circuit 50A Dual pole 40A x 2 Two independent 50A branch 50A dual pole (non-GFCI type) circuits (non-GFCI type) x 2 70A One 100A branch circuit 100A Dual pole NA NA NA (non-GFCI type) Service Panel GFCI Do not provide external GFCI as it may conflict with internal GFCI (CCID) Wiring -Standard 3-wire (1-1, L2, Earth) 5-wire (L1, L1, L2, L2, Earth) 3.2 Single Port EVSE Charger Connect L1 and L2 to the input safety breaker. BTC Power highly recommends crimp ferrule lugs to be used to make all electrical connection to the input safety breaker. In addition, a torque wrench should be used on the input breaker screw terminals. Set the wrench to a torque of 2ANM or 21.2 in/lbs. A pull test should be done on the wire connections to ensure proper connection. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 17 1 P a g e BTCPowrk--R 3.3 Dual Port EVSE Charger User Manual & Installation Instructions Connect L1 L2 on both phases to the input safety breaker. BTC Power highly recommends crimp ferrule lugs to be used to make all electrical connection to the input safety breaker. This requires the correct crimping tool. In addition, a torque wrench should be used on the input breaker screw terminals. Set the wrench to a torque of 2ANM or 21.2 in/lbs. A pull test should be done on the wire connections to ensure proper connection. Fig. 7a 1-1, L2 for left hand side charger 1-1, L2 for right hand side charger NOTE: SEPARATE LINES PER PORT ARE REQUIRED This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 181 Page BTCPowrk--R User Manual & Installation Instructions Check for ground cable on the door. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 19 1 P a g e BTCP�� User Manual & Installation Instructions 4 Operation 4.1 Screen Scenarios Out of Service BTCPou,CR Assaf ID: BTC5878 OUT OF SERVICE READY TO CHARGE No MCU Communication Connect Vehicle For assistance please contact customer service. Ready for Car to Plug In BTCPOWER A89at ID: BTC5878 Connect Vehicle Connect Vehicle Scan RFID or Use App BTCPcWER Asset ID: BTC5878 Scan RFID Card or Use App Connect Vehicle ID: BTC5678 RFID Invalid BTCPowt_R A—t ID, BTC5878 PAYMENT REOUIRED t RFID Card Invalid. Please Try Connect Vehicle Again. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 20 1 P a g e BTCP�II� User Manual & Installation Instructions Payment Timer Exceeded BTCPOWeR Asset ID, OTC5678 RECONNECT VEHICLE READY TO CHARGE Reconnect Vehicle Connect Vehicle Authorizing Payment BTCPaLunR Asset ID: DTC5078 Processing... Connect Vehicle Car Charging BTCPGWER Asset ID: 6TG5678 CHARGING READY TO CHARGE Energy 0.01 kWh Connect Vehicle Charger Voltage 253.58 VAC Charger Current B A Charging Completed BTCPoweR Asset l D: BTC5678 Please Unplug Charger and Connect Vehicle Return to Holder This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 211 Page BTCPowrk--R Car Unplugged User Manual & Installation Instructions BTCPoweR Asset Mi OTC5878 CHARGING SUMMARY READY TO CHARGE Plugged In Time: 333h 28m 4s Connect Vehicle Charge Time: 333h 28m 2s Energy: 0.01 kWh Internet Down BTCPowaR Asset I0: OTC5678 NETWORK DOWN READY TO CHARGE Please Contact Customer Connect Vehicle Support. Error Screen with Error# BTCPoLumm Asset I0: OTC5678 ERRORO READY TO CHARGE Please Call Customer Support. Connect Vehicle This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 22 1 P a g e BTCPowrk--R 4.2 WIFI Network User Manual & Installation Instructions This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 23 1 P a g e BTCPowrk--R User Manual & Installation Instructions How to connect the charger to local WIR network Start t y pressing F11 to minimize full screen mode. Once out of full screen the tap right Domer will give access to the system settings as shown BTCPawE Connect Vehicle Pe simal Appearance Brighthess& Language Lock Support Connect Vehicle This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 241 P a g e BTCPowrk--R Ofetess fireless User Manual & Installation Instructions It V Wired � 61RE�'r$�HP�F�iceJetPr�fi950 Wired ip r4al:work proxy Wireiess Wi r @ tess Wired 40 DIREGT-1113-HI30fflKjL�eLPF06964 Wired Network proxy Authentication rewired by Wi-Fi network. Passwords or encryption keys am req u ired to access the wi-Fi network'DIRECT$3+IPOFfirmiek PrQ6W'- IadSsward- � , Show password canrel Connect I Once the WE network is found and password is provided the unit will now be accessible online. Click back on the UI page on the web browser and click F11 again to gotofu II screen This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 251 P a g e BTCPowrk--R 5 TESTING User Manual & Installation Instructions 1. Once the charger has been installed by a qualified electrician and the breaker panel has been turned on and the breaker inside the charger has been turned on then the display should turn on and the system should turn on. Screen as shown in previous page should indicate operation. 2. If a vehicle is available, connect the EVP EVSE to the vehicle and verify that the contactor closes The main contactor should close and you should see charging on the main screen followed by power measurements displayed on the main screen. A) Free Vending Mode Remove the charging connector from its holder on the front of the charging station Open the J1772 plug cover on your vehicle (refer to the vehicles owner's manual. Plug the J1772 plug into the vehicle's charge port. Upon insertion, push down on the handle to lock it into place. Normally, the vehicle will immediately request a charge and the contactor inside the EVP EVSE can be heard closing. The display will show ready for charge followed by charging. To remove the connector from the vehicle, depress the button in the middle of the handle to release the connector. Place the charge connector back into the connector provided on the charge station. B) Access Control Mode • RFID • Credit Card Payment • Phone Application Front Display Panel The front panel display, will let the user know the status of the charger and if charging is taking place. If charging does not start This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 26 1 P a g e BTCPowrk--R User Manual & Installation Instructions In the event of a problem, charging will stop and an error message will appear on the front screen. If this happens, please try the two simple steps below before calling your field service representative. 1. Remove the cable connector from the vehicle socket. The error message on the screen may go off. Plug the connector back into the socket, and see if charging begins normally. If charging does not start, then call customer service. 2. If error code appears on screen and persists after removing the connector consider calling the Service group to investigate the issue. The user should record the Error Code shown on the display along with the station ID and date and time of the occurrence. 3. Alternatively if the error message does not go out when the connector is removed, be sure the connector is removed from the vehicle socket and switch off power at the circuit breaker feeding power to the EVSE. Wait a few seconds and switch the circuit breaker back on again. If the Protection light does not come back on, re -connect the cable to the vehicle. Charging should begin normally. If charging does not begin, call for Field Service. 6 TROUBLESHOOTING 5.1 Fault Codes Please look at the below data base for explanation of Fault Codes. No Fault 0 Welded Contactor 1 Broken Ground Pin 2 No Ventilation Available 3 Disconnected While Locked 4 Contactor Failed to Close 5 Contactor Failed to Open 6 GFCI Test Failed 7 GFCI Leak Detected 8 Program CRC Bad 1 9 "Note: Fault Codes only available with LCD equipped chargers This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev 0 Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 271 Page BTCPowrk--R 7 SPECIFICATIONS Input Power - Service Entrance User Manual & Installation Instructions Voltage & Wiring 208/240V AC single-phase -L1, L2, and Earth Ground Separate Branch Circuit per each EVSE Port. 3-wire (L1, L2, G) — for a single port 5-wire (L1, L2, G, L1, L2) — for a dual port Maximum Output Power. 6.2KW to 7.2KW per 30 amp per charge station 8.3KW to 9.6KW per 40 amp charge station 14.5KW to 16.8KW per 70 amp charge station Cable Length approximately (18-20ft.) Environmental rating Operating Temperature -30°C / + 600C NEMA Rating 3R; outdoor use with rain, snow, and sleet conditions. Weights: Single Port Pedestal: 70 Ibs Single Port Wall mount: 52 Ibs Dual Port Pedestal: 83 Ibs Dual Port Wall mount: 65 Ibs This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 28 1 P a g e BTCPowrk--R 7.1 DUAL PEDESTAL GENERAL DIMENSIONS 21.4 - 11.50 — User Manual & Installation Instructions 10.0 i" —i 9.50 85.2 This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 29 1 P a g e BTCPowrk--R 7.2 SINGLE PEDESTAL GENERAL DIMENSIONS 12 8� 77.6 56.3 User Manual & Installation Instructions 10.0 v.3 1 — 9.50 This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 30 1 P a g e BTCPowrk--R 7.3 DUAL WALL MOUNT GENERAL DIMENSIONS User Manual & Installation Instructions This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 311 Page BTCPowrk--R User Manual & Installation Instructions This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 32 1 P a g e BTCPowrk--R 7.4 SINGLE WALL MOUNT GENERAL DIMENSIONS User Manual & Installation Instructions This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 33 1 P a g e BTCPowrk--R User Manual & Installation Instructions LEVEL 2 AC CHARGE STATION COMMISSIONING GUIDELINE: This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 341 P a g e BTCPowrk--R User Manual & Installation Instructions Following the instructions on the installation manual are the AC input lines properly plugged in: Input voltages Single sided Charger SIDE A L1 VAC L2 VAC Charger SIDE B L1 VAC L2 VAC a. Is grounding lug properly secured? b. Is grounding wire connected to rear door? CHARGER INFORMATION: Charger Information Installation address Installation city State Charge box Serial Number Level 2 AC Single or Dual Installer name Installer phone number Installer email Install date Communications Cradle point IP Cradle point Serial number RFID Enabled NRG logo enabled TEST CHARGE SESSION PASS / FAIL INSTALLER SIGNATURE DATE PLEASE NOTE: ONCE INSTALLED PLEASE FAX THIS SHEET TO BTCPOWER:714.259.7998 This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 35 1 P a g e BTCPOWER User Manual & Installation Instructions BTCPOWER PRODUCT WARRANTY This Limited Product Warranty applies to customers who have purchased a BTCPower Electric Vehicle Charging Station(s) and/or a related product ("Product(s)") from Broadband Telecom Power, Inc., or one of its authorized distributors. LIMITED WARRANTY: Subject to the exclusions from warranty coverage set forth below, BTCPower warrants that the Product will be free from any defects in materials and/or workmanship (the "Limited Warranty") for a period of two (2) years after the date of the initial installation of the Product (the "Warranty Period"). If the Product becomes defective in breach of the Limited Warranty, BTCPower will, upon written notice of the defect received during the Warranty Period, either repair or replace, at BTCPower's election, the Product if it proves to be defective; provided, that BTCPower will not be responsible for the cost of any labor associated with the repair or replacement of any defective Product. You acknowledge that replacement products provided by BTCPower under the Limited Warranty may be remanufactured or reconditioned Products or, if the exact Product is no longer manufactured by BTCPower, a Product with substantially similar functionality ("Replacement Products") will be supplied. Any Replacement Products so furnished will be warranted for the remainder of the original Warranty Period or ninety (90) days from the date of delivery of such Replacement Product, whichever is greater. Should BTCPower be unable to repair the Product, BTCPower will replace the Product with the latest model/version of a similar product in current production. EXCLUSIONS FROM LIMITED WARRANTY IMPORTANT: The Limited Warranty and on your Product, shall not apply to defects, or service repairs, resulting from any of the following: • Force Majeure — any occurrence or extraordinary event or circumstance beyond the control of BTCPower that is an act of God or whether that occurrence is caused bywar, riot, storm, (such as hurricane, flooding, earthquake, volcanic eruption, etc.), or other natural forces, or acts of nature or other causes. This document is the Property of Broadband Telecom BTCPower EVP Series EVSE Rev O Power Inc. and will not be copied, reproduced, or used as Installation and Operations Manual the basis for sale or manufacture of apparatus without written permission. 36 1 P a g e BTCPowrk--R Retractable Assembly Installation Instructions Model Number Description EVP-RETR-001 Dual Pedestal Retractable Installation EVP-RETR-002 Single Pedestal Retractable Installation EVP-RETR-003 Dual Wall Mount Retractable Installation EVP-RETR-004 Single WaLt Mount Retractable Installation This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as the basis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 11 r d g e BTCPowrk--R Retractable Assembly Installation Instructions REVISION HISTORY Rev ate ECN # Description of BTC Power EVSE Engineer A 3/29/17 389 Initial Release Elmassry This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 21 P a g e BTCPCWr� Retractable Assembly Installation Instructions PLEASE NOTE This user's manual includes the latest information at the time of printing. BTC Power, Inc. (BTC Power) reserves the right to make changes to this product without further notice. Changes or modifications to this product by other than an authorized service facility could void the product warranty. If you have questions about the use of this product, contact your customer service representative. Refer to the Customer Support section located in this guide. WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer's responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 31 P a g e BTCPowrk--R Retractable Assembly Installation Instructions Table of Contents 1 INSTALLATION GUIDELINES & OVERVIEW...........................................................................................5 1.1 Before Installing...............................................................................................................................5 1.2 Overview............................................................................................................................................5 1.3 Special Tools & Hardware Torque Value.......................................................................................5 2 RETRACTABLE PEDESTAL MOUNT........................................................................................................7 2.1 Tools and Ancillary Equipment.......................................................................................................7 2.2 Assembly............................................................................................................................................8 3 RETRACTABLE WALL MOUNT..............................................................................................................14 3.1 Tools and Ancillary Equipment.....................................................................................................14 3.2 Assembly..........................................................................................................................................15 4 DRILLTEMPLATES.................................................................................................................................17 This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 4 1 P a g e BTCPowrk--R Retractable Assembly Installation Instructions 1 INSTALLATION GUIDELINES Et OVERVIEW 1.1 Before Installing Before any installation work is performed, study all drawings furnished by the supplier for the particular installation. These include arrangement drawings (front, end, and plan views), connections to the equipment that may be required to meet any local codes (such as mats, screens, or railings) is not furnished. 1.2 Overview Below is the Bill of Materials in the Retractable Assembly for Reference: rEM NO. PART NUMBER QTY. 1 BP-1396 2 Assy, Retractable Howling, Diecast 3 Extusion, Aluminum. 2x2 d Bracket, Base, Diecasi E Assy, Counterweight System 6 Cover, Base, Diecsa- 1.3 Special Tools Et Hardware Torque Value This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 5 1 F a g e BTCPowrk--R Retractable Assembly Installation Instructions Tools/Hardware J& Torque Specification Configuration 6-32 UNC 13 in-lbs. +/- 2 in-lbs. 10-32 UNF 30 in-lbs. +/- 5 in-lbs. 1/4-20 UNC 53 in-lbs. +/- 7 in-lbs. 1/2-13 UNC 48 in-lbs. +/- 7 in-lbs. M6 x 1 LIGUIDTIGHT FITTING 30 in-lbs. +/- 5 in-lbs. FUSE BLOCK LUGS, 8 AWG 40 in-lbs. +/- 5 in-lbs. FUSE BLOCK LUGS, 6 AWG 45 in-lbs. +/- 5 in-lbs. GROUND TERM. SCREWS, 14-10 AWG 34 in-lbs. +/- 5 in-lbs. GROUND TERM. SCREWS, 8 AWG 38 in-lbs. +/- 5 in-lbs. �/-20" LOCKNUT 12 ft-lbs. EVP-2001-XX-P EVP-2002-XX-P This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as the basis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 6 1 r d g e BTCPowrk--R Retractable Assembly Installation Instructions 2 RETRACTABLE PEDESTAL MOUNT 2.1 Tools and Ancillary Equipment Retractor Head Assembly A a 0 Retractor Brace IVII.IUC VVIC11L11 4F- Holster Template Retractor Pedestal Mount BOX WRENCH W Wo COMBINATION WflENCN 7/16" Box Wrench RIGHT SIDE O:fT 310E Retractor Base Template Y y I L�r Retractor Post 1/4-20 Nylock Nut Base Bracket Qty 4 1/4-20 x 5/8 Bolt Qty 4 This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 7 1 P a g e BTCP�I� 2.2 Assembly 1. 2. Retractable Assembly Installation Instructions When opening up the package, the Retractor head assembly and Retractor Post Bracket will be attached to each other. The Retractor Pedestal Mount will also be attached to the Retractor Brace with'/a-20 Bolts and Nuts. For new installations, detach the'/4-20 Bolts attached to the Retractor Brace from the Retractor Post. Proceed to step 4; Mountinz the Post to the Ground. Note: If you are Installing a Retractable Assembly on an Existing Level 2 Charging Unit, Skip to step 4. 3. Locate the Drill template for locating the retractor base bracket stud a. Based on the location of the charger the retractor base will need to have a separate stud to mount the retractor post base bracket. Provided is a drilling template for each side of the charger. Right side is indicated by facing the charger's display. b. Note that the following is not actual size. PDF file should be printed 1:1 scale to Locate the ideal location of the concrete stud to be drilled. This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 8 F' a g e BTCPowrk--R Retractable Assembly Installation Instructions 4. Locate the Holster Template and use this to drill 4 pilot holes which will later be oversized to .266 through holes for the'/4-20 Bolts. Template guild screw holes This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 9 N a g e BTCPCWr� Retractable Assembly Installation Instructions 5. Once four through holes have been drilled use the provided bolts to secure the two post brackets like the following picture: 6. Insert post into the charger mount bracket and tighten the provided bolts. This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 10 BTCPowrk--R Retractable Assembly Installation Instructions 7. Use the cord -set attached the retractor head assembly to pick the length of the charger plug to charger where the clamp will sit without letting the charger cord and plug to be off of the ground. Make sure the cord does not come in contact with the ground 8. Mark location of the clamp and wrap four layers of double sided gasket tape (included in this package) in that location This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 11 BTCPowrk--R Retractable Assembly Installation Instructions a. Assemble the retractor clamp over the four layers of double sided gasket tape. b. Attach the clamp assembly to the cord retractor head cord cable 9. Attach clamp assembly to the end of the cord clamp with provided screw Et nut. This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 121 BTCPowrk--R Retractable Assembly Installation Instructions 10. Test to make sure there is no binding on the cord retractor assembly prior to allowing the counter weight to be fully lowered. • Slight variation may be present from different charger models • Contact customer support at BTCPower for additional help This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 13 BTCPowrk--R 3 RETRACTABLE WALL MOUNT 3.1 Tools and Ancillary Equipment Retractor Head Assembly Retractable Assembly Installation Instructions RIGHT SIDE LEFT SIDE o Retractor Brace Collar Retractor Wall Mount BON WRENCH �fllF qIP EONBINAi ION WRENCH 7/16" Box Wrench Torque Wrench Retractor Base Template v�X d Retractor Post Base Bracket 1/4-20 x 1 Bolt Qty 1 Concrete Expansion Bolt Qty 2 1/4-20 Nylock Nut Qty 1 This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 14 I BTCP�I� Retractable Assembly Installation Instructions 3.2 Assembly 1. When opening up the package, the Retractor post will be attached to the Retractor Brace Collar with a'/-20 bolt and nut. 2. Bolt the Retractor Wall mount to the Wall approximately 40 inches from the base using Qty 2 Concrete Expansion bolts shown below: Note: For installation of the Concrete expansion bolts, consult a professional. 3. After installing the Retractable Wall Mount bracket to the wall, bolt the Retractable post to the Retractable wall mount. NOTE: Please allow for clearance from Retractable Post to swing Level 2 Charger for Servicing. This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 151 BTCPowrk--R Retractable Assembly Installation Instructions This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 16 BTCPowrk--R Retractable Assembly Installation Instructions This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 17 BTCPowrk--R 2X0.09rr .10 105 DOWEL PINS Retractable Assembly Installation Instructions 0 .13 THRU ALL This document is the Property of Broadband Telecom Power BTCPower EVP Series EVSE Rev J Inc. and will not be copied, reproduced, or used as thebasis Installation and Operations Manual for sale or manufacture of apparatus without written permission. 18