Loading...
Item 4E - Plansz 1 TRUE NORTH G C C/; G C SITE PLAN SCALE: 1 " = 40'-0" HARRELL DRIVE 1. Verify and document existing dimensions and conditions at the site before beginning construction. Notify the Architect of conflicts or variations prior to commencement of construction. 2. To prevent damage to existing trees and shrubs in proximity to the Work, provide and maintain protective barriers around those items in accordance with the specified procedures, or in the absence of those procedures, with recognized landscaping and horticultural practices. MV-11 l' 1U1-FV4'' V L K I A R C H I T I VLK Architects, Inc. 2821 West 7th Street, Suite 300 Fort Worth, Texas 76107 Main Phone: 817.633.1600 www.vlkarchitects.com ISSUED: March 20, 2020 Revision No. Revision Date 1 ASI 02 08/27/2020 2 ASI 06 04/28/2021 Director Drawn By LC CE Designer Quality Control JW MM Proj. Arch. JK 19104.00 ARCHITECTURAL SITE PLAN A1011 A TRUSTED PARTNER P.O. Box 151829, Fort Worth, TX. 76108 Submittal Review Form (817)467-4981 Project: 20-411 Keller ISD - Florence Elementary Subcontractor: Benchmark Signs Submittal Description: Submittal Number: Architect / Engineer: Signage: Exterior Letters 101400-03 VLK Architects ,f I Reviewed BUFORD-THOMPSON COMPANY GENERAL CONTRACTORS Approval of these drawings or data does not relieve the supplier from responsibility for quantities, errors or departures from the intent of the original contract documents. Date: 7/14/21 Job #: 20-411 By: J. Largent Submittal #:101400-03 A V L K I A R C H I T E C T S ❑ NO EXCEPTIONS TAKEN Architect's review is only for the limited purpose of checking for conformance with information given and the design X EXCEPTIONS NOTED concept expressed in the Contract Documents. Review is not conducted for the purpose of determining the accuracy REVISE & RESUBMIT and completeness of other details such as dimensions and quantities, or for substantiating instructions for installation or REJECTED performance of equipment or systems, all of which remain the responsibility of the Contractor. Review shall not relieve SUBMIT ADDITIONAL INFO the Contractor of the obligations required by the Contract Documents. Review shall not constitute approval of safety ACTION NOT REQUIRED precautions or, unless otherwise specifically stated by the 7/22/2�21 Architect, of any construction means, methods, techniques, DATE: sequences or procedures. Review and approval of a jkruse specific item shall not indicate approval of an assembly of BY: which the item is a component. Note: Attached is the Exterio Letter submittal from Benchmark. 35'-2" BENC11MAWK i S/GNS co -'ENCE ELEMEN A L C H 0 0 16", adjust proportional length as necessary SEE SHEET #2 FOR MOUNTING DETAILS. A3.01 - WEST ELEVATION - DETAIL 1 MANUFACTURER PRODUCT SIZE DEPTH MATERIAL FRONT PAINTED FONT MOUNT COLOR/FINISH GEMINI CUSTOM CAST 18" 1.5" ALUMINUM CLEAR ANODIZED ARIAL CUSTOM ALUMINUM LETTERS FINISH SEE SHEET 2 GENERAL CONTRACTOR NAME: BTC ARCHITECT NAME: VLK PROJECT: KELLER ISD - FLORENCE ES LOCATION: 3095 JOHNSON RD SOUTHLAKE, TX 76092 JOB NO.: P-11718-21 P.M.: APRIL CARNEY 817-560-9965 X107 acarney@benchmarksigns.biz DRAWN BY. JLO DATE: 7.12.2021 REVISION HISTORY: v1: v2 v3 v4 v5 DISCLAIMER: ALL SHOP DRAWINGS & ROOM SCHEDULES RECEIVED AS APPROVED OR APPROVED AS NOTED WILL BE FABRICATED AS SUCH. BENCHMARK SIGNS WILL NOT BE HELD RESPONSIBLE FOR ANY UNREVIEWED DESIGNS WITHIN THE RETURNED APPROVED SUBMITTAL OR APPROVED AS NOTED SUBMITTAL. -ALL DESIGNS PRESENTED ARE THE SOLE PROPERTY OF BENCHMARK SIGNS ,AND MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN PERMISSION FROM BENCHMARK SIGNS. Em-1 35-2" BENCHMARK( S/GNS VL LD pr ----------------- - 8'-0" 8'-0" 8'-0" 8'-0" 3'-7 1 /4" SEE DETAIL A 35'-611 SEE DETAIL B SEE DETAIL C ON SHEET 3 FOR MOUNTING INFORMATION. N- DETAIL A - FRONTVIEW C-CHANNEL DETAIL B - CUT THROUGH 16" �18" CAST ALUMINUM LETTER WHITE L EXAN- (BACK) 3/8" ALUMINUM GUSSET �1/4" WELDED ALUMINUM 1 /8" PLATE . - �END CAP BOLT BY OTHERS NOTE: HIDDEN CLIPS FOR FLUSH CONNECTING POINTS AT SEAMS (TYR) SEEMS: ----- GENERAL CONTRACTOR NAME: BTC ARCHITECT NAME: VLK PROJECT: KELLER ISD - FLORENCE ES LOCATION: 3095 JOHNSON RD SOLITHLAKE, TX 76092 JOB NO.: P-11718-21 P.M.: APRIL CARNEY 817-560-9965 X107 acarney@benchmarksigns.biz DRAWN BY: JLO DATE: 7.12.2021 REVISION HISTORY: v1: v2 v3 v4 v5 DISCLAIMER: ALL SHOP DRAWINGS & ROOM SCHEDULES RECEIVED AS APPROVED OR APPROVED AS NOTED WILL BE FABRICATED AS SUCH. BENCHMARK SIGNS WILL NOT BE HELD RESPONSIBLE FOR ANY UNREVIEWED DESIGNS WITHIN THE RETURNED APPROVED SUBMITTAL OR APPROVED AS NOTED SUBMITTAL. -ALL DESIGNS PRESENTED ARE THE SOLE PROPERTY OF BENCHMARK SIGNS AND MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN PERMISSION FROM BENCHMARK SIGNS. BENMMANAr SIGNS L' DETAIL C - EXAMPLE OF CAST LETTER WITH 2 STUD WELDED TO GUSSET 1 / \J L/V V I PANEL BAST LETTER 'STUD WELDED GUSSET GENERAL CONTRACTOR NAME: BTC ARCHITECT NAME: VLK PROJECT: KELLER ISD - FLORENCE ES LOCATION: 3095 JOHNSON RD SOUTHLAKE, TX 76092 JOB NO.: P-11718-21 P.M.: APRIL CARNEY 817-560-9965 X107 acarney@benchmarksigns.biz DRAWN BY: JLO DATE: 7.12.2021 REVISION HISTORY: v1: v2 v3 v4 v5 DISCLAIMER: ALL SHOP DRAWINGS & ROOM SCHEDULES RECEIVED AS APPROVED OR APPROVED AS NOTED WILL BE FABRICATED AS SUCH. BENCHMARK SIGNS WILL NOT BE HELD RESPONSIBLE FOR ANY UNREVIEWED DESIGNS WITHIN THE RETURNED APPROVED SUBMITTAL OR APPROVED AS NOTED SUBMITTAL. -ALL DESIGNS PRESENTED ARE THE SOLE PROPERTY OF BENCHMARK SIGNS , AND MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN PERMISSION FROM BENCHMARK SIGNS. gnu i ! i ml