Loading...
Item 7B - S-P-2 LetterZoning Document Philips Edison & Company Proposed Permitted Uses and Development Regulations for "SP-2" Zoning ZA21-0059 August 13, 2021 Permitted Uses: This property is proposed to be divided into 2 lots all of which would include permitted uses as found in the C-3 General Commercial District as described in Section 22 of the Comprehensive Zoning Ordinance. Permitted C-3 uses relative to this application consist of any use permitted in the C-2 Local Retail Commercial District with the following exceptions: 1. Frozen food lockers for individual or family use, not including the processing of food except cutting or wrapping 2. Bowling alleys 3. Conventional golf courses, including outdoor driving ranges accessory thereto, but excluding outdoor miniature golf courses 4. Lodges, sororities and/or fraternities 5. Medical care facilities to include nursing and care homes 6. Hospitals with their related facilities and supportive retail and personal service uses operated by or under the control of the hospital primarily for the convenience of patients, staff and visitors 7. Mortuaries 8. Funeral homes and undertakers 9. Skating rinks, ice and roller (indoor only) 10. Taverns, clubs and other comparable establishments under which the on -premise consumption of alcoholic beverages is permitted as required in Section 45 of Zoning Ordinance No. 480 11. Movie theaters DEVELOPMENT REGULATIONS: This property shall be subject to the development regulations for the C-3 General Commercial District, and all other applicable regulations with the following exceptions: 1. Impervious coverage will be allowed as shown at 86.45% and calculated for the site as a whole and not on a lot by lot basis. 2. Allowing parking to be provided for the site as a whole at 376 parking spaces instead of the required 549 parking spaces for an overall ratio of 1 space per 273 square feet of floor area. 3. The maximum permissible square footage for the restaurant located on lot 4R will be 2,100 square feet. 4. Allowing existing compact parking as shown. 5. Allowing the existing 5 parallel parking spaces next to the park and 8 parking spaces along the area north of the site and accepting the applicant's commitment that these spaces be constructed with grasscrete. 6. Allowing parking spaces and trash receptacle enclosures to encroach into the bufferyards as existing on Lot 2R1 and as proposed on Lot 4R. 7. Allowing no bufferyards to be required along internal lot lines due to an existing driveway in that location. 8. Allow South bufferyard as provided on the site plan. 9. To allow plans as shown with the understanding that the applicant will work with staff regarding the possibility of additional plantings of cedars be planted in the no disturbance zone adjacent to back of curb on the driveway in that area in lieu of the required 10' screening wall. 10. Allowing a flat roof with a parapet on a building less than 6,000 square feet on Lot 4R. 11. Allowing vertical and horizontal articulation on existing and proposed buildings as shown. Attachment A