Loading...
Item 7A - PresentationCITY VF OSOUTHL,4 ZA21-0045 Pieter Andries Jeweler Zoning Change and Site Plan APPLICANT: RPGA Design Group, Inc. OWNER: Pieter Andries Hye REQUEST: Approval of a Zoning Change and Site Plan from "S-P-1" Detailed Site Plan District with "C-2" Local Retail Commercial District Uses to "S-P-1"Detailed LOCATION: Site Plan District with "C-2" Local Reta Commercial District Uses. 2525 E. Southlake Boulevar C[TY UW SOUTHLAKE Future Land Use Pieter And ries Jeweler Future Land Use 100-Year Flood Plain - Corps of Engineers Property - Public ParklOpen Space - Public/Semi-Public Low Density Residential Medium Density Residential Office Commercial - Retail Commercial - Mixed Use - Town Center Regional Retail - Industrial Feet AG SFIA Zoning 2525 E. Southlake Blvd. SP2 I 7, Jk SPI SP2 01 AG Spi o SP2 Current Inning: SPI vaith 'C.2' I oral Retail Commercial District USeS Zoning Districts: = AG C1 RE C2 SFIA C3 s- is C4 SF2 wz-PuD SF30 HC SF20A 0 Bi SF206 0 B2 R-PUL) 0 11 MFI 12 MF2 L= Spi fm 0 SP2 CS DT ol TZD LE 02 0 ECZ WWI; 771- Ila A14 1.10 -AL- 625 .f 04 � p �' rzra "�oULe�gRD [ J P �`�'i�Y�1✓71�1;� �� BUILDING SQUARE FOOTAGE BUILDING FOOTPRINT 9,815 SF BUILDING SQUARE FOOTAGE EXISTING BUILDING GROSS SF NET SF FIRST FLOOR SECOND FLOOR 9,442 2,223 8,898 1.879 TOTAL SF 1 STORY ADDITION 11,665 GROSS SF 10,777 NET SF BUILDING ADDITION 198 180 TOTAL SF 198 180 New Addition _Y LOT YR-�. e�aa i o s io m w v 6EOR6EIdifJ P� a..0 P.R i.L.T. i.u.o, —L cauuwcixi 01 PROPOSED SITE PLAN TPUE SCALE: 1116' - l -W Proposed Site Piz SM DATA SU~RY CHART PREVOUSLY APPROVED CITY CASE NUMBER ZA18-0019 PROPOSED CITY CASE NUMBER ZA21-OM EXISTING ZONING SPI WITH C-2 USES 711XTH C-2 USES PROPOSED ZONING SPI WITH C-2 USES SPI 18TH C-2 USES LAND USE DESIGNATION LOO LOCAL RETAIL COMMERCIAL LOCAL RETAIL COMMERCIAL GROSS ACREACE M17 ACRES AR45 8917 ACRES 36,845 S MAXIMUM COVERAGE ALLOWED .4458 ACRES 19,421 Sq 5" 445B ACRES 19,421 Sn 50% MAXIMUM COVERAGE PROPOSED .2199 ACRES 9,574 25% 2243 ACRES %772 25% AREA OF OPEN SPACE .6714 ACRES 29,271 669 ACRES 29,030 SO PERCENTAGE OF OPEN SPACE 75% 75% AREA OF IMPERVIOUS COVERAGE BUILDING SIDEWALKS PAVING 9,574 SF 1.852 SF 11,672 SF .6680 ACRES (29,09B SF) 9,772 SF 1,552 SF 11,672 SF 0725 ACRES (29,296 SF) TOTAL IMWRMOUS COVERAGE PERCENTME CIF IMPERNOUS COVERAGE 15% (%ALLOWED = 70 76% M-OWED = 7 PROPOSED BUILDING AREA FOOTPMN 9,574 SF 9,772 SF NUMBER OF STORIES 2 2 MAXIMUM BUILDING HEIGHT 35 F 2.5 STORIES 35 FT 25 STORES PROPOSE) FLOM AREA A777 SF 10,957 SF PROPOSED FLOOR AREA BY USE RETAIL - 2,982 SF OFFICE - 4.854 SF STORAGE - 2.941 SF RETAIL - 3,162 SF OFFICE - 4,&A SF STORAGE - 2.941 S' REQUIRED PARKING RETAIL - 2.962/200 SF = 15 OFFICE - B FOR FIRST 1,DOOSF + U54 SF/3W -13 STORAGE-2941/1001) = 3 TOTAL REQUIRED - 39 ACCESSIBLE SPACES = 2 RETAIL - 3,162/2% $F = 16 OFFICE - 8 FOR FIRST I,000SF + 3,854 SF/300 -21 STORAGE-2.941/1000 = 3 TOTAL REWIRED - 40 ACCESSIBLE SPACES = 2 PROPOSED PARKING (9•A18') TYP. (I1'%18') TYP. (12'%18') TYP_ RETAIL/OFFCE 30 SPACES TOTAL ACCESSIBLE SPACES 2 SPACES TOTAL OFF SITE SPACES 0 SPACES TOTAL RETAIL/OFFICE 30 SPACES TOTAL ACCESSIBLE SPACES 2 SPACES TOTAL OFF SIZE SPACES 0 SPACES TOTAL TOTAL SPACES 32 TOTAL SPACES 32 RECORD LOADING SPACES 0 0 PROPOSED LpA]NC SPACES 0 0 AREA OF OUTSIDE STORAGE 0 D PERCENTAGE OF CU13DE STORACE 0 0 START CONSTRUCTION (MONTH/YEAR) 09/2018 09/2021 ENT CONSTRUCTION (MOITH/YEAR} 03/2019 01/2022 DtZ 1-UU4 s I:IR IAi"ll Building Elevations (ZA21=0045) Building Elevations Comparison SpU�CgkE @p r„�. RQ*J trL fVgRD . // r®eamuxecresaa.v� tmeoaLet a•wma �wemxseaeeen�aai 0 s0 0 61NL6iO —(ADD-4) rva imloeoum �'n® >� 0 0 - t slarcv eRKxd�snx.>ro ] `IV gygy _ 6EORGEIO'IM PMtlf CISPA CT�� 4J� 1 LII.R. RETAL mriEACJIL c wi sxl, e�aan 8917 ACRE CA&4 @f�R 1 PwTCi SIQ9Y �ORC1fN I�IiU -� R:.M5 MFi- a, o ffORfSci01111 PAR[ — — � TREE PROTECTIONRr'Ni Gawrnw LANDSCAPE PLAN Site Data Summary Chart Comparison Approved Approved Approved Proposed ZA14-069 ZA17-103 ZA18-0019 ZA21-0045 Existing Zoning C-2 SPA with C-2 uses SPA with C-2 uses SP-1 with C-2 uses Proposed Zoning SP-1 with C-2 uses SPA with C-2 uses SPA with C-2 uses SPA with C-2 uses Gross Area .89 acres 89 acres 89 acres 89 acres Number of Proposed 1 1 1 1 Buildings Existing Building Gross 8,091 SF Gross 8,091 SF Gross 8,091 SF Net: 10,777 SF Floor Area Net 7,569 SF Net 7,569 SF Net 7,569 SF 2-story addition: 2-story addition: 1 gt floor: 1 gt floor: 1-story addition: Gross 975 SF Gross 975 SF Gross: 198 SF Gross 2,522 SF Net 886 SF Net 886 SF Net: +180 SF Proposed Net 2,194 SF 2"d floor: 2°d floor: Additions Floor (includes 2-story Gross 1,006 SF Gross 1,006 SF Area addition and Net 837 SF Net 837 SF security area east Total: Gross 1,981 SF Total: Gross 1,981 SF addition) 1-story addition: 1-story addition: Gross 1,593 SF Gross 1,593 SF Net 1,485 SF Net 1,485 SF Total Building Gross 10,613 SF Gross 10,777 SF Gross 10,777 SF Net: 10,957 SF Floor Area Net 9,763 SF Net 9,774 SF Net 9,774 SF Required Parking (Per Ord.) 36 spaces 39 spaces 39 spaces 40 spaces Provided Parking 33 spaces 36 spaces" 32 spaces— 32 spaces"" Proposed Overall 1 space: 296 sf 1 space: 272 sf 1 space: 305 sf *" Parking Ratio "includes 4 off -site parking spaces — included in "S-P-1" regulations "" net area of 9,774 sf and does not include 2,941 sf of storage as noted in "S-P-1 ° regulations S-P-1 Regulations and Narrative • 2525 E. Southlake Boulevard, we are requesting S-P-1 Zoning with C-2 uses limited to Local Retail Commercial use. The property is an existing site and building that was developed as part of the Georgetown Park Development. • Since then, the site was subdivided and lots were sold individually. An increase of impervious coverage as indicated on the Site Data Summary Chart is requested as part of the application. • The property owner, International MBC, Inc. (Pieter Andries Hye) intends to add a small addition to the existing building on the ground floor of the building that faces north. Its use is intended for a floor area to be used for security/surveillance staff to be stationed during business hours. • The existing building is brick and stucco with fabric awning at the north side of the building. The proposed 1 story addition will be constructed using the same materials in keeping with the same design of the existing building. • Due to the proposed building additions, the impervious coverage exceeds the allowed impervious coverage under the current C-2 zoning by 5.5%. Part of the S- P-1 request is to allow for this greater impervious coverage percentage. • Based on the existing parking requirements per building square footage, the number of parking spaces required is 39. • The proposed new addition requires the increase of 1 parking space, for a total of 40 spaces. The number of parking spaces to be provided is 32. As the site is existing, no additional area is available to provide new parking spaces. As part of the SP-1 zoning, we are requesting the 32 parking spaces be acceptable instead of 40 spaces. • No grading plans are provided with this submittal. The location of the new building addition will not require any change to any existing grading. • No utility work (water, sewer or drainage) is provided with this submittal. No utility work will be required for the new building addition. • A waiver for the Traffic Impact Analysis is requested. Only 198 square feet of building space is being added to an existing retail jewelry shop. Thenb�eany additional parking or changes to existing driveways. /\/t)(_�( 1 % % i�� • No survey is provided with this submittal. Site plan drawing is accurate and based on a site survey conducted for the previous site plan submittal for this site to add other building additions. City Case number ZA18-0019. • No Pedestrian Access Plan is provided with this submittal. All sidewalks are existing. No sidewalks are to be added.���\11III I IIIlllllf� p g �. Development Regulations Comparison Pieter ., .. ..... .. Requirement ,,, Requirement ..:,,. 50 feet Front Yard (existing 50-feet (existing 50-feet (existing 50-feet (existing building 30-feet/C-2 district; 50 building building setback) building setback) setback) —feet/ FM 1709 setback) 1 space/ 296 sf 1 space/ 272 sf for 1 space/ 305 sf for 1 space/ 274 sf for all uses 1/200sf retail; 1/300 Parking for all uses (33 all uses (36 all uses (32 (32 provided) office; 1/1,000 storage provided) provided) provided) (36 required) 20' Type 0 on 20' Type 0 on the the north, none 20' Type 0 on the north, none on 20' Type 0 on the north, Bufferyards on east, south north, none on east, east, south & west, none on east, south & west, 20' Type 0 north; 5' A & west, allow south & west, allow allow as it currently allow as it currently exists east, south &west as it currently as it currently exists exists exists Articulation Allow as Allow as presented Allow as presented Allow as presented Complies with Corridor presented Overlay Max. Impervious 75% 74.9% 74.9% 75.5% 70% Coverage � / ,�X A /\,)< X X Site Photograph loom all a Site Photographs For: Opposed: Undecided Planning and Zoning Commission August 5, 2021; Approved (5-0) subject Report dated August 5, 2021, and Site Summary No. 2, dated July 30, 2021. to the Staff Plan Review CITY OF SOUTHLAKE CITY VF FIL a SOUTHL,4 Questions?