Combined Civil PlansX X X X X 1:12 RAMP DN UP UP UP UP DN DN 1:12 RAMP1:12 RAMP 1 : 1 2 R A M P CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 BLOCK 20, LOT 1R SOUTHLAKE TOWN SQUARE 1 LOT AN ADDITION TO THE CITY OF SOUTHLAKE TARRANT COUNTY, TEXAS BEING A 2.2427 ACRE TRACT OF LAND SITUATED IN THE RICHARD EADS SURVEY, ABSTRACT NO. 481 GARDEN DISTRICT AND PHASE C BROWNSTONES PLAT REVISION RECORDED IN INSTRUMENT NO. D214199946 P.R.T.C.T. DATED: SEPTEMBER 11, 2014 SITE DATA SUMMARY (LOT 1R, BLOCK 20) LAND USE DESIGNATION TOWN CENTER NO. OF PROPOSED LOTS 1 NUMBER OF STORIES BUILDING HEIGHT PERCENTAGE OF IMPERVIOUS COVER DT OPEN SPACE AREA OF IMPERVIOUS COVER EXISTING ZONING GROSS ACREAGE (LOT 1) START CONSTRUCTION MONTH/YEAR END CONSTRUCTION MONTH/YEAR BUILDING SQUARE FOOTAGE (PROPOSED) 97,692 SQ. FT. or 2.2427 ACRES GUEST PARKING PARKING STRUCTURE (REGULAR) PARKING STRUCTURE (HC) 29 BUILDING B BUILDING A BUILDING UNITS (#) BUILDING B BUILDING A 38,687 SQ. FT. 39.6% BUILDING USE GARDEN DISTRICT RESIDENCES 4 regular & 1 van 111 4 70,159 SQ. FT. 66,504 SQ. FT. 30 UNITS 28 UNITS BUILDING B BUILDING A 50'-7" 51'-1" 136,663 SQ. FT. 58 march 2023 september 2024 1.44 ACRES / 64.2% PERCENTAGE OF SITE COVERAGE OF BUILDING 35.0% BUILDING FOOTPRINT (SQUARE FOOTAGE) BUILDING B BUILDING A 17,540 SQ. FT. 16,626 SQ. FT. 34,166 SQ. FT. RI C H A R D E A D S S U R V E Y ABS T R A C T N O . 4 8 1 T. M A H A N S U R V E Y AB S T R A C T N O . 1 0 4 9 D LOT TABULATION BLOCK LOT SQ. FT. ACRES 20 1R 97,692 2.2427 20 2R 22,246 0.5107 X X X X X X X X X X X X X X X CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X X X X X X X X X X X CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X 1:12 RAMP DN UP UP UP UP DN DN 1:12 RAMP1:12 RAMP 1 : 1 2 R A M P CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X PEDESTRIAN STAIR AND RAMP ABOVE LINE OF BUILDING A ABOVE OUTLINE OF EXIT STAIR @ LVL 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 37 38 39 40 41 42 43 44 464748495051525354555657596061626364656768 71 72 73 74 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 9798 9699100101104102103107105106110 108 109113111112 114 115116 ELEV 1 STAIR 1 ELEV 2 STAIR 2 ELEV 1 STAIR 2 LINE OF BUILDING B ABOVE OUTLINE OF EXIT STAIR @ LVL 1 TRANSFORMERS BUILDING A & B UP UP UP DN Emeregency ELEC. ELEC.Room Building storage and Maintenance Gas & Water TRASH ELEV. LobbyELEV. Lobby ELEV. LOBBYTRASH Trash/ Recycling STAIR 1 Emergency Generator Fire Riser 36 45 66 70 80797877 Open Space TBD UP UP 69 7675 58 CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X 1:12 RAMP DN UP UP UP UP DN DN 1:12 RAMP1:12 RAMP 1 : 1 2 R A M P CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X 1:12 RAMP DN UP UP UP UP DN DN 1:12 RAMP1:12 RAMP 1 : 1 2 R A M P CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X 1:12 RAMP DN UP UP UP UP DN DN 1:12 RAMP1:12 RAMP 1 : 1 2 R A M P CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X 1:12 RAMP DN UP UP UP UP DN DN 1:12 RAMP1:12 RAMP 1 : 1 2 R A M P CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 1.All construction shall be in strict accordance with the standards of the City of Southlake and governed by the North Central Texas Council of Government's Standard Specifications for Public Works Construction latest edition. 2.All materials and workmanship shall conform to the City of Southlake standards where they differ from NCTCOG standards. 3.The Texas Department of Transportation (TxDOT) must approve any work to be done in the state highway right-of-way. An application and appropriate plans must be submitted directly to TxDOT for review. 4.A permit is required to cut a city street or work within the right-of-way. The permit is issued by the Public Works Department. 5.The location of underground facilities indicated on the plans is taken from public records. It is the contractor's responsibility to make arrangements with the owners of such underground facilities prior to working in the area to confirm their exact location and to determine whether any additional facilities other than those shown on the plans may be present. The contractor shall preserve and protect all underground facilities. If existing underground utilities are damaged, the contractor will be responsible for the cost of repairing the utility. UNDERGROUND FACILITY OWNER TELEPHONE NUMBER Above Net Fiber (214) 869-8352 AT&T (214) 745-2964 AT&T Texas (call DIGTESS)(800) 344-8377 Atmos Energy (817) 359-1313 Charter Communications (817) 822-8745 City of Southlake (817) 748-8082 DIGTESS (Line Locates) (800) 344-8377 Level (3) Communications (877) 366-8344 Oncor Electric Delivery (817) 215-6688 One Source Communications (817) 692-6042 TRI County Electric (817) 431-1541 Verizon Engineering (972) 578-3354 6.Where existing utilities or service lines are cut, broken or damaged, the Contractor shall replace or repair the utilities or service lines with the same type of original material and construction, or better, unless otherwise shown or noted on the plans, at his own cost and expense. The Contractor shall immediately notify the Engineer at once of any conflicts in grades and alignment. 7.All excavations, trenching and shoring operations shall comply with the requirements of the U.S. Department of Labor, OSHA, “Const. Safety and Health Regulations.”, Vol. 29, Subpart P. pg. 128 - 137, and any amendments thereto. 8.Adequate measures shall be taken to prevent erosion. In the event that significant erosion occurs as a result of construction the Contractor shall restore the eroded area to original condition or better. 9.The Contractor shall restore all areas disturbed by construction to original condition or better. Restored areas include, but are not limited to trench backfill, side slopes, fences, culvert pipes, drainage ditches, driveways, private yards and roadways. 10.Any changes needed after construction plans have been released, shall be approved by the City Engineer. These changes must be received in writing from the design engineer. The Director of Public Works shall approve any deviations from state regulations. 11.The contractor shall provide “red lined” marked prints to the Engineer prior to final inspection indicating all construction which deviated from the plans or was constructed in addition to that indicated on the plans. 12.The contractor must field verify existing service locations prior to installing new services. When installing a new water line, all existing services must be connected to the new line. 13.The contractor shall keep records for Record Drawings and shall submit markups to the city inspector prior to scheduling a final walkthrough inspection. 14.Prior to construction, a pre-construction meeting shall be held with representatives from all contractors, the engineer and the City of Southlake. 15.All construction must adhere to the Tree Preservation Ordinance. 16.All 1” and 2” water meters will be installed by City personnel. 17.Fire hydrants shall be located outside of sidewalk if walk intended. 18.All water lines shall be PVC pipe conforming to AWWA standard C-900 SDR-18 minimum, with NSF seal, pressure tested and disinfected in accordance with NCTCOG STD. SPECS. Water mains to have a minimum of 42” cover to the top of pipe. Service line connectors shall be compression-type with stainless steel tube liners. 19.All water lines not under pavement to be encased in sand and backfill shall be select material compacted to 95% standard proctor density. Pipe including services under public pavement requires cement treated sand backfill. 20.Water services should be located 10' upstream of the sanitary sewer services. Each location is to be stamped on the curb with 2” high letter “W”. 21.All services to the meter to be minimum 1” SDR-9 class 200 polyethylene. 22.Water meter boxes will be furnished and installed after paving activities have been completed. 23.Curb stops should be tested for leakage and full flow when system is pressure tested. 24.All fire hydrant assemblies to be equipped with a 6” gate valve and box. Hydrants shall be installed with a factory based prime coat only. Hydrants will be painted by the City. 25.Any water valves located within pavement areas shall be adjusted to final grade by the paving Contractor. The paving Contractor shall construct a typical concrete block out per detail on sheet. 26.Fire hydrants shall be equipped with 4-1/2”x5” Storz adapter connection with butterfly vanes. 27.When a water line is bored, the casing shall be capped and valves added on either side. 28.All fittings and bends shall have Mega Lug retainer glands. 29.For valves installed 4' and deeper, extension with center ring 2' or less is required. 30.Sanitary sewer PVC pipe shall be SDR 35 if depth of line is 10' or less and SDR 26 if depth of line is greater than 10'. 31.Pipe not under pavement shall be bedded in class II, or better, material as defined in ASTM D-2321, and placed as directed therein. Backfill shall be select material compacted to 95% standard proctor density. Pipe, including services under public pavement requires cement treated sand backfill. 32.After completion of all testing (i.e. mandrel & air) Contractor shall perform a Television inspection and provide videotape to the Public Works Department. Deflection testing shall be performed as specified in special conditions. 33.A 2” high letter “S” shall be stamped on the curb to mark the location of the sewer services. The service should be located in the center of each lot. 34.One joint of 150-psi pressure rated pipe shall be installed under all proposed water pipe crossings. 35.Contractor to place a ¾” plywood false bottom in all sanitary sewer manholes before paving Contractor begins work. 36.Rim elevations of the proposed sanitary sewer manholes in streets are to be constructed 18” below final finished grades by utility contractor and adjusted by paving Contractor to finished grade at time of paving. Each shall have a typical concrete block-out constructed per standard detail. 37.All trenches shall be compaction tested at the rate of one test per 300 L.F. of trench per lift. Lifts shall be no greater than 12” loose. Tests shall be staggered so that tests of adjacent lifts are not directly over the previous lift. If the distance between manholes exceeds 300 L.F., a minimum of 2 tests per lift shall be taken. The testing lab shall provide the location of all results on a plan and profile sheet prior to trench acceptance. The paving contractor shall not begin work until the City of Southlake has approved all trench work. 38.All manholes shall be vacuumed tested. 39.Any service tie-in to an existing manhole must be cored. 40.Clean-outs to be provided on all services and located at the property/ROW line. 41.Television test shall be provided on DVD to City of Southlake. X X X X X 1:12 RAMP DN UP UP UP UP DN DN 1:12 RAMP1:12 RAMP 1 : 1 2 R A M P CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 X X X X X CITY OF SOUTHLAKE, TEXAS SOUTHLAKE TOWN SQUARE LOT 1, BLOCK 20 "D " S E E P L A N V A RIE S S A N D "X " STANDARD CONSTRUCTION DETAILS WATER WATER DETAILS S D -0 1 W A T E R .D W G L A S T S A V E D : 9 /4 /2 0 1 5 8 :1 1 A M P R I N T E D : 5 /9 /2 0 1 3 1 2 :0 1 P M SANITARY SEWER DETAILS STANDARD CONSTRUCTION DETAILS SEWER S D -0 2 S E W E R .D W G L A S T S A V E D : 9 /4 /2 0 1 5 8 :2 6 A M P R I N T E D : 5 /9 /2 0 1 3 1 2 :0 1 P M 2 0 'm i n ."R " 4 " R 2 " R STANDARD CONSTRUCTION DETAILS PAVING HMAC PAVING DETAILS S D -0 4 P V M T -H .D W G L A S T S A V E D : 9 /4 /2 0 1 5 8 :3 2 A M P R I N T E D : 5 /9 /2 0 1 3 1 2 :0 1 P M STANDARD CONSTRUCTION DETAILS DRAINAGE STORM DRAIN DETAILS 1. ALL CONCRETE SHALL BE CLASS "A" (5 BAGS OF CEMENT PER C.Y. AND A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 3000 PSI). ALL EXPOSED CORNERS SHALL BE CHAMFERED 3/4" UNLESS INCORPORATED INTO SIDEWALK. 2. IN GENERAL, REINFORCING STEEL SHALL BE NO. 4 BARS, ON 12" CENTERS EACH WAY FOR GUTTER, BOTTOM SLAB, ENDS, AND FRONT AND BACK WALLS, AND NO. 4 BARS ON 6" CENTERS EACH WAY FOR TOP SLAB IN BOTH INLETS AND EXTENSIONS. ADDITIONAL REINFORCING STEEL SHALL BE PLACED AROUND MANHOLES AS SHOWN. 3. ALL REINFORCING STEEL SHALL BE OPEN HEARTH NEW BILLET STEEL OF INTERMEDIATE OR HARD GRADE CONFORMING TO ASTM A-15. DEFORMATIONS SHALL CONFORM TO ASTM A-305-56T. 4. ALL REINFORCING STEEL SHALL HAVE A MINIMUM COVER OF 2". 5. 8'-0" OF EXISTING CURB AND GUTTER UPSTREAM AND 4'-0" OF EXISTING CURB AND GUTTER DOWNSTREAM SHALL BE REMOVED AND RE-POURED INTEGRALLY WITH EACH INLET. 6. DIMENSIONS RELATING TO REINFORCING STEEL ARE TO THE CENTER OF BARS. 7. ALL BACKFILL SHALL BE PERFORMED BY MECHANICAL TAMPING. 8. PRECAST INLETS MUST BE APPROVED BY CITY ENGINEER. 9. ALL STORM SEWER MUST BE VIDEO INSPECTED BY CONTRACTOR. CONTRACTOR SHALL FURNISH THE CITY WITH DVD FOR APPROVAL PRIOR TO ACCEPTANCE. 10. ALL STORM DRAIN STRUCTURES 36" DEEP OR DEEPER MUST HAVE FIBERGLASS STEPS INSTALLED. FRAME TO BE ANCHOR BOLTED OR CAST INTO JUNCTION BOX OR INLET ASSEMBLY TO BE FURNISHED WITH A CHAIN RETENTION DEVICE. FRAME AND COVER SHALL BE EAST JORDAN IRON WORKS PRODUCT NO. 35506214, CATALOG NO. 226L BASS LOGO, "106-4L ASSEMBLY WITH LOCK" OR APPROVED EQUAL. S D -0 6 D R A I N 1 .D W G L A S T S A V E D : 9 /3 /2 0 1 5 2 :4 2 P M P R I N T E D : 5 /9 /2 0 1 3 1 2 :0 1 P M STANDARD CONSTRUCTION DETAILS DRAINAGE STORM DRAIN DETAILS S D -0 7 D R A I N 2 .D W G L A S T S A V E D : 9 /3 /2 0 1 5 2 :4 2 P M P R I N T E D : 5 /9 /2 0 1 3 1 2 :0 1 P M STANDARD CONSTRUCTION DETAILS DRAINAGE STORM DRAIN DETAILS S D -0 8 D R A I N 3 .D W G L A S T S A V E D : 9 /4 /2 0 1 5 9 :0 0 A M P R I N T E D : 5 /9 /2 0 1 3 1 2 :0 1 P M CITY OF SOUTHLAKE TEXAS STORM SEWER