Loading...
Plan-setRELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVING JURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNAdvancedSolarSolutions 39650MallardBassLake,CA93604 PHONE: 559-321-7000EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSED WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SITE / PROJECT DETAILS SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE ALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONS ARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHER JURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCAL JURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSO APPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDED AND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJ REQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT 2018 2018 2018 2020 CONNECTION NORTH ⅊ ⅊ ⅊ ⅊ D R I V E W A Y HARBOR REFUGEMAIN RESIDENCE POOL ACCESSORY STRUCTURE ASCE 7-16 WIND SPEED: 11.730 KW 10.704 KW PV-001 COVER SHEET Burchett, Larry Ryan Pruitt Tri-county Electric 1131951 - Ryan Pruitt(817) 690-1456 City Of Southlake rpruitt@currentsolar.us 83664 Civil (202) 874-3483swyssling@wysslingconsulting.com R-3 Risk Category II Exposure C 5 N/A Scott E. Wyssling 76 North Meadowbrook Dr (817) 690-1456 Alpine, UT 84004 rpruitt@currentsolar.us VB ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 3000 Altamesa Blvd, Suite 300 Current Solar LLC. Fort Worth, tx 76133 MISSION SOLAR MSE345SX5T SolarEdge SE11400H-US (240V) IronRidge XR100 Rail IronRidge FlashFoot2 INTEGRATED IN INV & OPT N/A 34 1 N/A 50 N/A N/A N/A (E) 3 120/240V - 1 37°, 33° 260°, 270° ROOF COVERING 115 Comp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS N/A 225A BUS/200A MAIN BREAKER BACK-FED BREAKER PV-001(817) 690-1456 Burchett, Larry2910 Harbor Refuge, Southlake, TX 76092 Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS PROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS *ALLNOTESAREASAPPLICABLETOTHISPROJECT. CONNECTORSSHALLBERATEDFORWETLOCATIONS. ORBETTERRATED.ALLEXTERIORCONDUITAND3R EXTERIORELECTRICALEQUIPMENT,SHALLBENEMAALL STANDARDSBYALICENSEDCONTRACTOR. ANDGENERALBUILDINGANDROOFINGWORKMANSHIP SEALANTANDFLASHINGSWHEREREQUIREDPERCODE MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SHALLBESEALEDANDPENETRATIONSROOFTOPALLNEW :*WATERPROOFING .NEC110.12COMPLIANCEWITH BESECUREDINAWORKMANLIKEMANNERIN WILLPVMODULECONDUCTORSLOCATEDUNDERARRAYS .NEC200.6(A)(6)COMPLIANCEWITH MAYBEFIELD-MARKEDWHITEINPVWIREBLACKWIRE 2020NEC690.4(B)WITH FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE .PVMODULESWIRELEADSSHALLBELISTED690.31(C)(1) 2020NECASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE SHALLUSECONDUCTORSLISTEDANDIDENTIFIEDCIRCUITS EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT 310.15(B)(3)(4)(c) 2020NECSUNLIGHTINACCORDANCEWITH THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT ASAPPLICABLETOALLCONDUCTORSSHALLBEDERATED .NEC690.8,NEC690.7 INCOMPLIANCEWITHALLCONDUCTORSSHALLBESIZED TOUPSIZING. MINIMUMCODEREQUIREMENTSANDARENOTLIMITED CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND FORTHEIRINTENDEDPURPOSEINCLUDINGWET ITANDCONDUCTORSSHALLBEAPPROVEDALLCONDU DUITNOTES:*WIRING&CON .UL1699(B)LISTEDANDLABELEDINACCORDANCEWITH ANDSHALLBEUL1699B,NEC690.11COMPLIANCEWITH BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN GREATER.ALLDCPVCIRCUITSINSTALLEDINORON WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR FORALLPVSYSTEMSONORPENETRATINGABUILDING ISREQUIREDARCFAULT(AFCI)DCCIRCUITPROTECTION NEC690.9PROTECTIONINCOMPLIANCEWITH ;BOTHREQUIREOVERCURRENTUNGROUNDED BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE .240AND705.12,NEC690.8,690.9COMPLIANCEWITH SHALLBEINALLOCPDRATINGSANDTYPESSPECIFIED 2020NEC690.15(D) WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN REMAINBOTHPOSITIVEANDNEGATIVEPVCONDUCTORS 2020NEC690.15(A).DISCONNECT ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY SHALLBEPROVIDEDADDITIONALACDISCONNECTS NEC110.28PER DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER TYPE”KNIFEBLADE“SHALLBEAACDISCONNECTS ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND SHALLBELABELED,LOCKABLE,OFALLACDISCONNECTS (TYPICALLYTHEUPPERTERMINALS) OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS WILLBECONFIGUREDSOISCONNECTINGSWITCHESALLD ANDOCPDNOTES:*DISCONNECTS NEC690.9INSTALLATIONINSTRUCTIONSAND TOASINGLEOCPDINACCORDANCEWITHTHEIR SHALLBECONNECTEDMICROINVERTERBRANCHCIRCUITS 2020NEC705.12(B)(5)FROMADDITIONALFASTENING FORINVERTEROUTPUTISEXEMPTBACKFEEDINGBREAKER 230.42 NECENTRANCECONDUCTORSINCOMPLIANCEWITH WITHSERVICENEC705.12(A)COMPLIANCEWITH AREINSUPPLYSIDETAPINTERCONNECTIONS 705.12(B)(2)(3)(b) 2020NECALSOBESIZEDAPPROPRIATELYASPER ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED 2020NEC705.12(B)(2)(1)COMPLIANCEWITH AREINALLFEEDERTAP(LOADSIDE)INTERCONNECTIONS NEC705.12(B)(2)(3)(c)COMPLIANCEWITH EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS 2020NEC705.12(B)WITH AREINCOMPLIANCE-SIDEINTERCONNECTIONSALLLOAD /POCNOTES:*INTERCONNECTION 2020NEC690.41(B)FAULTPROTECTION DCGROUND-PVSYSTEMSSHALLBEPROVIDEDWITH .AHJANDNEC250,NEC690.47COMPLIANCEWITH GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A .NEC250.106THROUGHNEC250.50ANDNEC690.47 COMPLIESWITHTHEGROUNDINGELECTRODESYSTEM MODULE. NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES SHALLBETHEGROUNDINGCONNECTIONTOAMODULE REQUIREMENTS. HOLESPERTHEMANUFACTURER'SINSTALLATION MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS APPROVEDUL2703INSTALLATIONMANUAL.IF SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S MODULEANDRACKGROUNDINGAPPROVEDUL2703 .NEC250.134ANDNEC250.136(A)COMPLIANCEWITH RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN CONDUCTIVEPARTSOFMODULEFRAMES,MODULE .250.122 NECTABLECONDUCTORSSIZEDINACCORDANCEWITH ANDMINIMUMGROUNDNEC690.43WITH INCOMPLIANCEMETALPARTSSHALLBEGROUNDED MODULEFRAMESANDOTHERINCLUDINGPVEQUIPMENT .250.136(A) NECAND250.134NECGROUND,INCOMPLIANCEWITH EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUNDINGCONDUCTOR.ALLMETALELECTRICAL AREUNGROUNDEDANDREQUIREANEQUIPMENT ONLYTHEDCCONDUCTORSEDSYSTEMSINUNGROUND NGNOTES:*GROUNDI RACKINGMANUFACTURESENGINEEROFRECORD. OUTLINEDBYTHEMAXSPANSTHEPRE-ENGINEERED ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ANDSHALLBEINSTALLEDINACCORDANCEUL1703WITH NDLABELEDINACCORDANCESHALLBELISTEDAROOFTOP &PVPANELSMOUNTEDONARACKINGSYSTEM NOTES:* ANDINSTALLATIONSTRUCTURAL APPLICABLE. WHENPURPOSEANDRATEDFOROUTDOORUSAGE LISTEDFORTHEIRINTENDEDALLCOMPONENTSARE APPLICABLECODES. NECWITHINCOMPLIANCEQUALIFIEDPERSONNEL ACCESSIBLETOALLEQUIPMENTSHALLBEINSTALLED 2020NEC690.15(A)SERVICINGDISCONNECT. WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SHALLBEPROVIDEDADDITIONALACDISCONNECT(S) .NEC690.34 INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH AREPERMITTEDTOBEDPULLBOXESJUNCTIONAN NOTES:* TLOCATIONS&ELECTRICALEQUIPMEN 2020NEC690.12(A)-(D)WITH CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE THATRAPIDSHUTDOWNFUNCTIONSHALLINCLUDEA ITSINSTALLEDONORINBUILDIDNGPVSYSTEMCIRCU WNNOTES:*RAPIDSHUTDO REQUIREMENTS. CLASSIFICATIONSASALLUL,IEC,IEEEAND NEC690.4AND690.6SYSTEMSINCOMPLIANCEWITH COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV TO,MODULES,INVERTERSANDSOURCECIRCUIT ;INCLUDINGBUTNOTLIMITEDPVSYSTEMCOMPONENTS NEC110.26.PROVIDEDASPERSECTION EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE AROUNDESSANDWORKINGCLEARANCEPROPERACC :*GENERALNOTES N-001Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPN2018 IFC ROOF ACCESS REQUIREMENTS THE FOLLOWING INFORMATION INDICATES THE REQUIRED ROOF TOP CLEARANCES FOR PANELS/ARRAYS INSTALLED ON RESIDENTIAL BUILDINGS WITH SLOPES GREATER THAN 2:12: ROOF ACCESS POINTS - ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. HIP ROOF LAYOUTS - PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH HIP ROOF LAYOUTS SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3-FOOT-WIDE CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS/MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE LOCATED AT A STRUCTURALLY STRONG LOCATION ON THE BUILDING CAPABLE OF SUPPORTING THE LIVE LOAD OF FIRE FIGHTERS ACCESSING THE ROOF. SINGLE RIDGE - PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO, 3-FOOT-WIDE ACCESS PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS/MODULES ARE LOCATED. HIPS AND VALLEYS - PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH ROOF HIPS AND VALLEYS SHALL BE LOCATED NO CLOSER THAN 18 INCHES TO A HIP OR A VALLEY WHERE PANELS/MODULES ARE TO BE PLACED ON BOTH SIDES OF A HIP OR VALLEY. WHERE PANELS ARE TO BE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY THAT IS OF EQUAL LENGTH, THE PANELS SHALL BE PERMITTED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY. RESIDENTIAL BUILDING SMOKE VENTILATION - PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS SHALL BE LOCATED NO HIGHER THAN 3 FEET BELOW THE RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE VENTILATION OPERATIONS. PV SITE LAYOUT LEGEND * EXISTING DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS SEE HATCH DEFINITION BELOW *NOTE: DESIGNATION OF RIDGE, HIP, AND VALLEY DOES NOTAPPLY TO ROOFS WITH 2:12 OR LESS PITCH. kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAG SECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 NORTH SECTION 2 SECTION 1 3' FIREPATHWAYS 18" FIRE SETBACK PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/24” = 1’0” @ SHEET SIZE A3 1883 SECTION-1 361 34.52% 260 37°SECTION-1 270 33°SECTION-2 289SECTION-2 QTY 34 MISSION SOLAR MSE345SX5T MODULES QTY 1 SolarEdge SE11400H-US (240V) INVERTER PV-100RCurrent Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESS* EXISTING ROOF DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFING COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/RETRO FIT FLASHING * DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAG SECTION #MODULE GROUP B. ANCHOR SPACING SHOWN IN DETAIL. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS. SEE "TABLE OF DIMENSIONS" EACH SECTION DETAILED FOR HORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENT MANUFACTURERS. ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO ROOF RACKING RAIL NORTH32'-634"1 0 '-9 1 4 "26'-314"10'-91 4" SCALE: 1/24” = 1’0” @ SHEET SIZE A3 Rafter - Strut to Walls Below 24" O.C. 2"x6" @ 24" MAX OC Comp Shingle 2.85 PSF QTY 34 MISSION SOLAR MSE345SX5T MODULES QTY 1 SolarEdge SE11400H-US (240V) INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 9:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 6’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND 21SCALE: NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODE REQUIREMENTS AT THE TIME IT WAS BUILT. C. STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING IS ACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL BE NO MORETHAN TWO LAYERS.(SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUT SIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES. STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION # MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSPER RAIL MANUFACTURER MAX RAFTER SPANMAX RAFTER SPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILSARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL HORIZONTAL SPAN HORIZONTAL SPAN RISE 12 VERIFY WALL OR BEAMBELOW ATTIC STRUT RIDGE BEAM FRAMING OH1HS2HS1R2R1* IF BLOCKING REQUIRED32 S-201 DIAGONAL AND/ORVERTICAL ATTIC STRUTS 1 5 6 73 PV1 D1 D3 D2 D2 1 S-201H1 HORIZONTAL SPAN HORIZONTAL SPAN RISE 12 VERIFY WALL OR BEAMBELOW ATTIC STRUT RIDGE BEAM FRAMING OH1HS2HS1R2R1* IF BLOCKING REQUIRED32 S-201 DIAGONAL AND/ORVERTICAL ATTIC STRUTS 1 5 6 73 PV1 D1 D3 D2 D2 1 S-201H1 BOLTLAG5/16X4.75" 2.5"MINEMBEDMENT ASSY, FLASHING IRONRIDGEASSY,CAPFOOT WASHER, EPDMBACKED IRONRIDGE (E) FRAMING @ 24" O.C. TYPICAL 2'-0"TYP 6'-0"MAX STRUTS TO WALL(S) / RAFTER - PORTRAIT STRUTS TO WALL(S) / RAFTER - LANDSCAPE EXPLODED STANCHION & FLASHING DETAIL STANCHION SPACING DETAIL XR100 Rail FlashFoot2 Integrated 12" 37°, 33° 3" - 6" TYP 10.37" 20.75" 21" 6" 6" 12" 37°, 33° 3" - 6" TYP 17.2" 34.41" 34.66" 6" 6" 15' Comp Shingle NOT USED 11'-9" MAX 11'-9" MAX S-200PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND * DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATIONINSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE: NTS 3 4 SCALE: NTS SCALE: NTSSCALE: NTS ATTACHMENT DETAILSROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION # MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSROOF RACKING RAIL 1/3" OF TOTAL SPAN MAX 2/3" OF TOTAL SPAN MAX RAIL MANUFACTURER RAIL SPLICE KIT SEE "S-100 / TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE. SEE SHEET "S-100" FOR: HORIZONTAL ANCHOR SPAN SPACING. (E) FRAMING TYPICAL * MODULES SHOWN PORTRAIT IN EXAMPLE DC AND/OR 1/3 CANT. MAX COMPONENT + 2" FROM SIDEOF MODULE 2" ROOF TOP CONDUIT EXTENSION OF RAIL RAIL OR STRUTCONNECTIONS TO MEET WEIGHT REQ. OF EQUIPMENT DCB * MODULES SHOWN PORTRAIT IN EXAMPLE ** RAILING SHOWING IN VERTICAL IN EXAMPLE RIDGE BEAM *R2*R1VERIFY THAT NO DIAGONAL AND/OR VERTICAL ATTIC/FRAMING STRUT MEMBERS ARE CUT OR NOTCHED * SEE DETAILS "1-2/S200" TABLE OF DIMENSIONS HOLES ALLOWED ONLY IN MIDDLE HALF OF FRAMING SPAN 1/4 1/4 HOLES ALLOWED ONLY IN MIDDLE THIRD OF FRAMING DEPTH, *R2, AND NO LARGER THAN *R2/4 IN DIAMETER. MINIMUM SPACING BETWEEN HOLES AT *R2 FRAMING SAG IN INCHES NOT TO EXCEED FRAMING LENGTH IN FEET DIVIDED BY 20 NOTCHES DEEPER THAN 1/4" NOT ALLOWED ALONG TOP OR BOTTOM EDGE OF FRAMING NOTE: WHERE FRAMING IS VISIBLE FROM ATTIC &/OR UNDERSIDE OF ROOF, VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURAL DECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. RIDGE SAG IN INCHES NOT TO EXCEED RIDGE LENGTH IN FEET DIVIDED BY 20 STANCHION ATTACHMENT DETAIL RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL RAFTER HOLE AND CONSTRUCTION DETAIL S-201Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STC TEMPERATURE CORRECTEDTEMPERATURE MFR. PMAX TEMP COEFFICIENT [-0.#%/C] * 100 FORMULA CORRECTED TEMP.COEFFICIENT MODULE Voc [VDC] TEMPERATURE CORRECTEDOPEN CIRCUIT VOLTAGE - =*= +*=EQUIP. CALCULATIONSPV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/ PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (OPERATING CURRENT)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC DC/DC OPTIMIZER (IF APPL.) MANUFACTURER MODEL NUMBER WEIGHT Ibs RATED OUTPUT isc AMPS MAX OUTPUT VOLTAGE VOLTS MAX INPUT VOLTAGE Voc VOLTS DC COMBINER / DISCONNECT #1 MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPS DC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS STRING INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATED AC DISCONNECT AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) ADDRESSTHICK WATTSMAX. AC APPARENT POWER kW PHOTOVOLTAIC PLANSDC COMBINER / DISCONNECT #2 (IF APPL.) MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPS DC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS AMPS MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT QTY MAX PV MODULE Voc MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE AMPS DC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS VOLTS DC VOLTS DC MAX INPUT FUSE/BREAKER RATING DC COMBINER / DISCONNECT #3 (IF APPL.) QUANTITY STRING INVERTER #2 SPECIFICATIONS (IF APPL.) AMPS - MAX MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATED AC DISCONNECT AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT WATTSMAX. AC APPARENT POWER QUANTITY INVERTER(S) INVERTER(S) AC COMBINER #1 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 AMPS (Imax) AMPS (Imax) AC COMBINER #2 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AMPS (Imax) AMPS (Imax) AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS AMPS (Imax) MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 ALT. ENERGY BACKFEED BREAKER (IF APPL.) SUM OF EXISTING CIRCUIT BREAKERS MISSION SOLAR Eaton DG222URB1MSE345SX5T44.8 68.82 x 41.49 x 1.57 NON-FUSIBLE DISCONNECT 120/240345 41.033.3710.92 60 44.69 10.34 3R2 N/A 47.5-0.26 20.0 SolarEdge Technologies P400 Single (240V)1.8 1560 80 Proposed SolarEdge SE11400H-US (240V) 11400 38.8 480 400 48030.5 N/AYES NO 240 11400 70 47.5 LOAD CENTER 2 3R OR BETTER225 200 200 7060 -9 25 -34 -0.26%0.09 1 1.09 41.0 44.69 1 E-001EXISTING 120/240V Single Phase225 200 2570 Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING AMPACITY CHECKCORRECTED AMPACITY CALCULATION TEMPRATING TRADESIZE AMPACITY PER 310.16 MAXCURRENT 690.8 (A)(1) CONT.OPERATION 690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVE ROOF (in) TEMP. ADDER PER310.15 (B)(2)(c) OPERAT.TEMP. AMPACITY CORRECTION310.15 (B)(2)(a) # OFUNGRND.COND. AMPACITY CORRECTION310.15 (B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILL DERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY DC1 XXX=XX=< DC2 XXX=XX=< DC3 XXX=XX=< DC4 XXX=XX=< DC5 XXX=XX=< AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] CIRCUIT ORIGINTAG CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING AMPACITY CHECKCORRECTED AMPACITY CALCULATION TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION 690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVE ROOF (in) TEMP.ADDER PER310.15 (B)(2)(c) OPERAT. AMPACITYCORRECTION310.15 (B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15 (B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X =WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3. 4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. WHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED. / PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT ARE EQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY NGROUNDED CONDUCTOR(S).U TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES APN ADDRESS kW PHOTOVOLTAIC PLANSAC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < DC6 X XX=XX =< DC7 XX X=XX =< DC8 XX X=XX =< #OFCOMBINEDPARALLELSTRINGS DESTINATION QTY INPARALLEL & MATERIAL QTY INPARALLEL & MATERIAL lsc (AMPS) ORCOMPONENT(AMPS) MAX INV. OUTPUT CURRENT (AMPS)ORCOMPONENT(AMPS) WIRE COLOR CODING (2020) CEC NEC SECTIONS 250.119 & 200.6 PV MODULE DC/DC CONVERTER (1) CU 90 #12 AWG 30 10.92 1 1.25 1.25 17.06 ROOFTOP 39 >7/8"0 39 0.91 2 N/A 30 0.91 1.0 27.3 17.06 27.3 DC/DC CONVERTER JUNCTION BOX (1) CU 90 #10 AWG 40 15 1 1 1.25 18.75 ROOFTOP 39 >7/8"0 39 0.91 6 N/A 40 0.91 1.0 36.4 18.75 36.4 JUNCTION BOX INVERTER (1) CU 90 #10 AWG 40 15 1 1 1.25 18.75 ROOFTOP 39 >7/8"0 39 0.91 6 0.80 40 0.91 0.80 29.12 18.75 29.12 74.8N/A 0 0.88 200.0 INVERTER AC DISCONNECT (1) CU 75 #4 AWG 85 1.25 47.5 59.4 EXT WALL 39 39 3 1.0 85 0.88 1.0 74.8 59.4 AC DISCONNECT SUB-PANEL (1) CU 75 #4 AWG 85 1.25 47.5 59.4 EXT WALL 39 N/A 0 39 0.88 3 1.0 85 0.88 1.0 74.8 59.4 74.8 SUB-PANEL EXISTING SERVICE PANEL (1) CU 75 #3/0 AWG 200 1.0 200 200.0 200 E-002Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT LEGEND RELEASEREVDATE NAME ADDRESSTHREE LINE DIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 3 DC DISCONNECT 4 DC COMBINER BOX 5 JUNCTION BOX 6 RAPID SHUTDOWN 7 AC/DC INVERTER 8 AC/DC INVERTER W/ INTE AC DISC 9 AC DISCONNECT (FUSIBLE) 10 SOLAR LOAD CENTER 11 PROD/GENERATION METER 12 SUB PANEL 13 14 15 EXISTING UTILITY METER NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED TAG APN ADDRESSSEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS kW PHOTOVOLTAIC PLANSELECTRICAL NOTES UNGROUNDED PV SYSTEMS: •DINVERTERS, MODULES, AND DC COMPONENTS MUST BE LISTEFOR USE IN UNGROUNDED SYSTEMS, TYPICALLY TRANSFORMER-LESS (TL) •NS.OCPD'S WHERE NECESSARY MUST HAVE DISCONNECTING MEA •PV SOURCE CIRCUITS MUST BE EITHER PV WIRE AND LISTED FORWET LOCATIONS OR JACKETED MULTI-CONDUCTOR CABLESINSTALLED IN RACEWAY. •OR.THE AC SIDE IS STILL GROUNDED ON THE NEUTRAL CONDUCT •REQUIRE EQUIPMENT GROUNDING BUT DOES NOT HAVE SYSTEM GROUNDING; NO DC CURRENT-CARRYING CONDUCTOR ISCONNECTED TO GROUND. THESE CONDUCTORS ARE COLORCODED DIFFERENTLY THAN GROUNDED PV SYSTEMS. AC/DC ELECTRICAL NOTES: •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BERATED FOR 600 VOLTS ON THE DC / PV POWER SIDEOF THE INVERTER. •EXTERIOR ENCLOSURES TO BE NEMA TYPE 3R OR BETTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FOR WET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FOR BACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS, UNLESS OTHERWISE MARKED,ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINE” AND “LOAD” SHALLNOT BE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITY )INTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND STRING MODULE QTY INVERTER# BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 DC2 DC3 DC4 DC5 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE CONDUIT TABLE AC6 AC7 AC8 AC9 AC10 DC6 DC7 DC8 16 AC DISCONNECT (INDEPENDENT) • * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS G N MAIN C/BRATING BUSRATING M EGC 15 16 200A 225A 60A GEC 225A G N BUSRATING 12 GEC AC3 (-)(+) (-)(+) DC DC 2 2 1 1 (-)(+) (-)(+) DC DC 2 2 1 1 (+) (+) 2 2 DC(-) (-)DC 1 1 EGC DC1 DC DC DC DC DC DC AC G N G L2 L1 3 7 6 DC G G 5 DC 3 INVERTER NAMEPLATE RATING 11400W /240V L2 L1 L2 L1 NN 9 AC1 AC2 DC2 MODULE NAMEPLATE RATING 345W G G G 200A TO (E) LOADCENTER AC DISCONNECT NAMEPLATE RATING 60A/240V 10 MODULES 10 MODULES 14 MODULES 34 MISSION SOLAR MSE345SX5T 34 P400 Single (240V) 0 INTEGRATED IN INV 0 1 4x4 Metal 0 INTEGRATED IN INV & OPT 1 SolarEdge SE11400H-US (240V) 0 1 10 Eaton DG222URB INV 1 2 10 INV 1 3 14 INV 1 1 0 0 1 0 1 1 120/240V - 1 60A 2 #12 AWG PV Wire #6 AWG N/A Open Air 7 #10 AWG PV Wire #6 AWG N/A Open Air 0 7 #10 AWG THWN-2 #8 AWG 3/4"EMT 4 #4 AWG THWN-2 #8 AWG 1"EMT 4 #4 AWG THWN-2 #8 AWG 1"EMT 4 #3/0 AWG THWN-2 #2 AWG 2"EMT E-003DC/DC OPTIMIZER EXISTING MAIN SERVICE PANEL 225A BUS/200A MB NEW MAIN SERVICE PANEL Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT(N) 225A BUS/200A RELEASEREVDATE NAME ADDRESSAPNELECTRICAL SYMBOL LEGEND AC DISCONNECT DC DISCONNECT DC COMBINER BOX AUTO TRANSFORMERCB DC AC ATF DCB DC DISCONNECTINGCOMBINER BOX ELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES MUST BE CONNECTED TO THE EGC (EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSOR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBS ARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKING SPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2. FOR "LAY-IN" LUG MODULE GROUNDING; CORRECTHARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED,TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BEATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TO BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETAL PARTS THAT MIGHT COME INTO CONTACT WITHCURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THEMETAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS,DISCONNECTS, METERS, JUNCTION BOXES AND COMBINERBOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTSTO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THECONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THESYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT,OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECTCONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING, USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP ADDRESS kW PHOTOVOLTAIC PLANSSOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATTINV#DC/AC STRING INVERTER CLP CRITICAL LOADS PANEL SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP PERFORMANCE METER UTILITY METER P M XFMR TRANSFORMER JUNCTION BOXJB RSD RAPID SHUTDOWN SUB-PANELSUB ATS AUTO TRANSFER SWITCH SP INVMAC NORTH PROPOSED UNDERGROUND CONDUIT TRENCH LENGTH 50FT JB JB SUB SCALE: 1/24” = 1’0” @ SHEET SIZE A3QTY 34 MISSION SOLAR MSE345SX5T MODULES QTY 1 SolarEdge SE11400H-US (240V) INVERTER E-100PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER.Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSHEET NOTES1SCALE: 1/2" = 1'-0"CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 2 3 5 6 8 SCALE: 1/4" = 1'-0"9 10 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12" FROM BENDS, 12" ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE: NEC 690.31(G)(3) 3.MINIMUM OF 1 1/8" x 5 3/4" 4.FONT: 3/8" AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX, DC COMBINER, AND DC DISCONNECT WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SCALE: 1/4" = 1'-0" 1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITSOR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSEDDURING SERVICE. 3.MINIMUM OF 3" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. NON-LOAD BREAK DC COMBINER / J-BOX WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SCALE: 1/2" = 1'-0" 1.PLACED ON DC DISCONNECT(S) AND ON ANYEQUIPMENT THAT STAYS ENERGIZED IN THE OFFPOSITION FROM THE PV SUPPLY. 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 3 1/2" x 10" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. INVERTER(S)SCALE: 1/2" = 1'-0" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 1.A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATEDON OR NO MORE THAN 1M (3 FT) FROM THE SWITCH THATINCLUDES THE FOLLOWING: 2. 3. MINIMUM OF 3 1/2" x 10 1/2" 4. FONT: 3/8" WHITE LETTERS ON A RED BACKGROUND. AC AND DC DISCONNECTS PV SYSTEM DISCONNECT 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 1" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" DC COMBINER BOX 1. 2. USE PLACARD "COMBINER # 1" WHEN MORE THAN 1DC COMBINER IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1" x 4" 4. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR WHITE LETTERS ON A RED BACKGROUND. 1.CODE REFERENCE: NEC 690.13(C) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1" x 6" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1.USE PLACARD ON CUSTOMER GENERATION METER. 2.VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. SOLAR kWh METER SCALE: 1/2" = 1'-0" INVERTER # 1 1.USE PLACARD "INVERTER # 1" WHEN MORE THAN 1INVERTER IS USED. NUMBER ACCORDING TO THREELINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1" x 4" 3.FONT: 3/8" 4.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2" = 1'-0" USE PLACARD "[AC][DC] DISCONNECT # 1" WHEN MORETHAN ONE DISCONNECT IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 11 SCALE: 1/4" = 1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE PLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROM THE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN PLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.13 & 690.53) 4.THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOWALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS ANDBARRIERS. (IFC 605.11.1.4, NEC 690.31[G][3] ) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATEOR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOTCOVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THELOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT, NON-BOLD. 7.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 7.4.CONTRASTING BACKGROUND AND LETTERING. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT STANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSCODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL) DO NOT DISCONNECT UNDER LOAD 7 RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZEDAND HAVING A MINIMUM HEIGHT OF 9.5 MM (3⁄8 IN.),IN WHITE ON RED BACKGROUND. 2. 1/4" = 1'-0" SCALE: 2CODEREFERENCE:NEC690.56(C)(1)(a) 3TITLE:MIN.3/8"BLACKCHARACTERSONYELLOWBACKGROUND,REMAININGCHARACTERSMIN.3/16"INBLACKONWHITEBACKGROUND. 1LOCATENOMORETHAN1mFROMTHESERVICEDISCONNTMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDSHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDSHUTDOWNSWITCHESIFNOTATTHESAMELOCATION. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS INVERTER(S) QTY 34 MISSION SOLAR MSE345SX5T MODULES QTY 1 SolarEdge SE11400H-US (240V) INVERTER P-001Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PVINVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2. MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICEDISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEMDISCONNECTION MEANS. 3. CODE REFERENCE: NEC 690.56(A)(B), 705.10 4. WHITE LETTERS ON A RED BACKGROUND. 5. MINIMUM OF 7 3/4" x 5" 6. FONT: 3/4" "CAUTION", 1/4" "WARNING", 3/16" HEADER, 1/8" DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEDISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERETHE DISCONNECT IS OPERATED. (IFC 605.11.1.3)RELEASEREVDATE NAME ADDRESSAPNSHEET NOTES 1. 2. 3. 4. COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[E][3], NEC 690.31[E][4] & 690.53) REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT, NON-BOLD. 5.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 5.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS. 5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVED MANUFACTURED PRODUCT 6.ANSI Z535.4 PRODUCT SAFETY SIGNS AND LABELS: THIS INFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDS MAY BE USED WITH PRIOR APPROVAL OF THE AHJ.MOST NOTABLE DIFFERENCES IS COLOR OF PLACARDS AND USEOF HAND WRITTEN VALUES WITH INDUSTRIAL MARKERS ONSTANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT AFUTURE DATE. I.E. ADDING MODULES AT A FUTURE DATE, OR STANDARD PLACARD MANUFACTURER INSTALLED ONELECTRICAL COMPONENT. AHJ APPROVAL REQUIRED. (SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 SCALE: 1/4" = 1'-0"2 3 4 1.PLACARD PLACED ON EACH DISCONNECT, IF MORE THAN ONE PRESENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / DC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.53 4.MINIMUM OF 2 1/2" x 8" OR 5" x 2 1/2" RESPECTIVELY. 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. 7.IN SOME CASES TWO LABELS MAY BE REQUIRED. AN INVERTER WITHINTEGRATED DC DISCONNECT UTILIZING TWO MPPT TRACKERS; IF CONFIGURATIONUSES DIFFERENT MODULES. SCALE: 1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE: 1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE PV SYSTEM DC DISCONNECT ADC PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDC 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / AC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.54 4.MINIMUM OF 1 1/2" x 8 1/2" OR 1 3/4" x 6 1/2" RESPECTIVELY. 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1) PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEM SUPPLY BREAKER AT POINT OF INTERCONNECTION. (#2 & #3) PLACARD(S) REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT(S) ARE NOT LOCATED NEXT TO EACH OTHER. MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS. IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS; SEE SHEET "E-001 / STRING INVERTER[#] SPECIFICATIONS". 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. 2.1.2."RATED AC OUTPUT CURRENT" WILL BE THE SUM OF THE INVERTERS 2.1.3."AC NORMAL OPERATING VOLTAGE" WILL BE THE NAME PLATE RATING OF THE INVERTER 3.CODE REFERENCE: NEC 690.54, NEC 705.12(B)(3) 4.MINIMUM OF 2" x 6 1/2" (#1), VARIES (#2 & #3) 5.FONT: 3/8" HEADER, 3/16" DATA (#1), 1/4" (#2 & #3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE: 1/2" = 1'-0" CAUTION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND ATTHE PV INVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICE DISCONNECTING MEANS ANDPHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 6 1/2" x 6 1/2" 6.FONT: 3/4" "CAUTION", 1/4" HEADER, 1/8" DATAAND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAINSERVICE DISCONNECT IN A LOCATION CLEARLYVISIBLE FROM WHERE THE DISCONNECT IS OPERATED. (IFC 605.11.1.3) DC DISCONNECTS & DISCO. COMBINER DYNAMIC PLACARDS(WITH COMBINED WARNING PLACARD IF REQUIRED. EXAMPLE: LADWP) PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT #1 #2 #3 RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING STRING INVERTER #1 - INTEGRATED AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS STRING INVERTER #2 - INTEGRATED AC DISCONNECT AC DISCONNECT #1 - INDEPENDENT/ SEPARATE AC SUB-PANEL #1 ADDRESS kW PHOTOVOLTAIC PLANS#1 #2 #3 CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL)VDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC 1.PRIME CONTRACTOR / PERMIT APPLICANT SIGNERIS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEM INSTALLATION. PRIME CONTRACTOR / PERMIT APPLICANT SIGNER WILL BE RESPONSIBLE FOR COLLECTION OF EXISTING ONSITE INFORMATIONREQUIREMENTS TO DESIGN, SPECIFY, AND INSTALLTHE EXTERIOR MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEM DETAILED IN THIS DOCUMENT. 2.ADVANCED SOLAR SOLUTIONS, INC ISRESPONSIBLE FOR APPLYING SUPPLIEDINFORMATION INTO A SET OF PERMIT DRAWINGS.ANY CHANGES TO DRAWINGS ARE SUBJECT TOCONTRACT CONDITIONS BETWEEN THE CLIENTAND ADVANCED SOLAR SOLUTIONS, INC. INACCORDANCE WITH THE REQUIREMENTS OF THEAHJ. RESPONSIBILITY NOTES N N(E) UTILITY METER & SERVICE PANEL INVERTER W/ DC DISCO SOLAR ARRAY ON ROOF TOP INVERTER W/ DC DISCO (E) UTILITY METER & SERVICE PANELSOLAR ARRAY ON ROOF TOPSUB PANEL SUB PANEL& AC DISCO & AC DISCO 47.5240240 47.545.0 45.0 240480480 47.5 P-002Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT &60.7*5(9PLVVLRVRODUFRPLIRPLVVLRVRODUFRP 06(3(5& 0(5,&60'(&030 06(3(5& &(5,),('5(,%,, 7HVWHGWR8/,(&VWDGDUGV 3,UHVLVWDW 5HVLVWDFHWRVDOWPLVWFRUURVLR '&('(&+ 3(5&DGEVEDUGULHPRGOHHIILFLHF ,GHDOIRUDOODSSOLFDWLRV (5(0(:(+(55(6,,(&( 3DIURWDG3DEDFNORDG 7HVWHGORDGWR8/ %&03,)5(50(35-(&6 %PHULFDFW PHULFD5HFRHU5HLHVWPHWFW )50()50(:55 HJUDGDWLRJDUDWHHGRWWRH[FHHGLHDURHDG DDOOIURPHDUVWRWRLWKJDUDWHHGL HDU &(5,),&,6 UL 61730 IEC 61215 - IEC 61730 IEC 61701 3OHDVHFRWDFW0LVVLR6RODU(HUJLIRKDHTHVWLRVRUFRFHUVDERWFHUWLILFDWLRRIRUSURGFWVLRUDUHD6WDGDUGHDUSURGFWDUUDWH[WHGDEOHWRHDUVLWKUHJLVWUDWLR HUXHPHULFD%UDG 0LVVLR6RODU(HUJLVKHDGTDUWHUHGL6DWRLR7H[DV KHUHHPDIDFWUHRUPRGOHV:HSURGFHPHULFDKLJK TDOLWVRODUPRGOHVHVULJWKHKLJKHVWLFODVVSRHURWSW DGEHVWLFODVVUHOLDELOLW2USURGFWOLHLVWDLORUHGIRU UHVLGHWLDOFRPPHUFLDODGWLOLWDSSOLFDWLRV(HU0LVVLR SolarEnergysolarmoduleiscertifiedandsurpassesindustry VWDGDUGUHJODWLRVSURLJH[FHOOHWSHUIRUPDFHRHUWKH ORJWHUPHPDGWKHEHVWGHPDG0LVVLR6RODU(HUJ &66(',3:(53: 36,,(3:(5(5&(WR MissionSolarEnergyreservestherighttomakespecification d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lEOL0&5HKH ((&5,&63(&,),&, 3URGXFWSH 06(6 3PD 3RHU2WSW3PD[:S 0RGOH(IILFLHF 7ROHUDFH 6KRUW&LUFLW&UUHW,VF9 2SH&LUFLW9ROWDJH9RF 5DWHG&UUHW,PS9 5DWHG9ROWDJH9PS9 )VH5DWLJ 6VWHP9ROWDJH9 6+,33,,)50, &RWDLHU)73DOOHWV3DHOV:%L REOH6WDFNN: REOH6WDFNN: 3DOOHW>3DHOV@ :HLJKW OEV NJ +HLJKW L FP :LGWK L FP /HJWK L FP &(5,),&,6(6 6 ,(& 8/ %6,&',0(6,6 81,76PP ˚C / / / / //t /t /t /t /tCurrent [A] 06(6:3&(650'(&55((&5( 9ROWDJH>9@&UUHWROWDJHFKDUDFWHULVWLFVLWKGHSHGHFHRLUUDGLDFHDGPRGOHWHPSHUDWUHRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSPV MODULE CUT SHEET R-100Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT 15756VRODUHGHFRP 2SWLPLHLVWDOODWLRLWDYHWHFROR Specicallydesignedtoworkwith poweroptimizers Built-inmodule-levelmonitoring Outdoorandindoorinstallation Optional:Revenuegradedata,ANSIC12.20 Class0.5(0.5%accuracy) Record-breakingeciency Fixedvoltageinverterforlongerstrings Integratedarcfaultprotectionandrapidshutdownfor NEC2014and2017,perarticle690.11and690.12 Extremelysmall UL1741SAcertied,forCPUCRule21grid compliance 6LOH3DVHYHUWHULWDYH7HFROR IRU1RUWPHULFD SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ SE7600H-US/SE10000H-US/SE11400H-US 55517 686 686 686 686 686 686 686 287387 5DWHG3RZHU2XWSXW#9#9 #9#9 #9#9 9 0DLPXP3RZHU2XWSXW#9#9 #9#9 #9#9 9 2XWSXW9ROWDH0L1RP0Dü ü ü ü ü ü ü 9DF 2XWSXW9ROWDH0L1RP0Dü ü ü 9DF )UHTXHF1RPLDO+ 0DLPXPRWLXRXV2XWSXWXUUHW#9 0DLPXPRWLXRXV2XWSXWXUUHW#9 ),7UHVROG 8WLOLW0RLWRUL,VODGLProtection,CountryCongurable7UHVROGV <HV 1387 0DLPXP3RZHU#9 : 0DLPXP3RZHU#9 : 7UDVIRUPHUOHVV8URXGHG<HV 0DLPXP,SXW9ROWDH 9GF 1RPLDO,SXW9ROWDH 9GF 0DLPXP,SXWXUUHW#9GF 0DLPXP,SXWXUUHW#9GF 0D,SXW6RUWLUFXLWXUUHW GF 5HYHUVH3RODULW3URWHFWLR<HV URXG)DXOW,VRODWLRHWHFWLRN 6HVLWLYLW MaximumInverterEciency CECWeightedEciency #9#9 1LWWLPH3RZHURVXPSWLR: 7217856 6XSSRUWHGRPPXLFDWLR,WHUIDFHV 56(WHUHWL%HHRSWLRDOHOOXODURSWLRDO 5HYHXHUDGHDWD16,2SWLRDO 5DSLG6XWGRZ1(DGXWRPDWLF5DSLG6XWGRZXSRULGLVFRHFW 67152031 6DIHW8/8/68/%6DDGLD),DFFRUGLWR7,/0 ULGRHFWLR6WDGDUGV ,(((5XOH5XOH+, (PLVVLRV )3DUWODVV% 167721637216 2XWSXWRGXLW6LH:5DH PLLPXP:PLLPXP: ,SXWRGXLW6LHRI6WULV:5DH 3/4”minimum/1-2rings/14-6AWG 3/4”minimum/1-3rings/14-6AWG LPHVLRVZLW6DIHW6ZLWF+:LPP :HLWZLW6DIHW6ZLWFlb/kg 1RLVHG% RROL1DWXUDORYHFWLR 2SHUDWL7HPSHUDWXUH5DHWRWR(-40˚F/-40˚Coption)˚F/˚C 3URWHFWLR5DWL1(0,YHUWHUZLW6DIHW6ZLWF )RURWHUUHLRDOVHWWLVSOHDVHFRWDFW6RODU(GHVXSSRUWAhighercurrentsourcemaybeused;theinverterwilllimititsinputcurrenttothevaluesated5HYHXHUDGHLYHUWHU316(+8611)RUSRZHUGHUDWLLIRUPDWLRUHIHUWRhttps://www.solaredge.com/sites/default/les/se-temperature-derating-note-na.pdf YHUVLR316(+86118 6LOH3DVHYHUWHULWDYH7HFRORIRU1RUWPHULFD SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ SE7600H-US/SE10000H-US/SE11400H-US ©SolarEdgeTechnologies,Inc.Allrightsreserved.SOLAREDGE,theSolarEdgelogo,OPTIMIZEDBYSOLAREDGEaretrademarksorregisteredtrademarksofSolarEdgeTechnologies,Inc.Allothertrademarksmentionedhereinaretrademarksoftheirrespectiveowners.Date:12/2018/V01/ENGNAM.Subjecttochangewithoutnotice.RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSINVERTER CUT SHEET R-101Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT 32(52370(5 39SRZHURSWLPLDWLRDWWHPRGOHOHYHO SpecicallydesignedtoworkwithSolarEdge inverters Upto25%moreenergy Flexiblesystemdesignformaximumspace utilization Fastinstallationwithasinglebolt Nextgenerationmaintenancewithmodule- levelmonitoring MeetsNECrequirementsforarcfault protection(AFCI)andPhotovoltaicRapid ShutdownSystem(PVRSS) Module-levelvoltageshutdownforinstaller andreghtersafety Superiorefciency(99.5%) Mitigatesalltypesofmodulemismatchlosses, frommanufacturingtolerancetopartial shading 3RZHU2SWLPLHU )RU1RUWPHULFD P320/P340/P370/P400/P401/P405/P485/P505 (55517 ©SolarEdgeTechnologiesLtd.Allrightsreserved.SOLAREDGE,theSolarEdgelogo,OPTIMIZEDBYSOLAREDGEaretrademarksorregisteredtrademarksofSolarEdgeTechnologies,Inc. Allothertrademarksmentionedhereinaretrademarksoftheirrespectiveowners.Date:04/2020/V02/ENGNAM.Subjecttochangewithoutnotice. (6)Fordetailedringsizinginformationreferto:http://www.solaredge.com/sites/default/les/ring_sizing_na.pdf(7)ItisnotallowedtomixP405/P485/P505withP320/P340/P370/P400/P401inonering(8)Aringwithmorethan30optimizersdoesnotmeetNECrapidshutdownrequirements;safetyvoltagewillbeabovethe30Vrequirement(9)For208Vgrid:itisallowedtoinallupto6,500Wperringwhenthemaximumpowerdifferencebetweeneachringis1,000W(10)For277/480Vgrid:itisallowedtoinallupto15,000Wperringwhenthemaximumpowerdifferencebetweeneachringis2,000W 3RZHU2SWLPLHU )RU1RUWPHULFD P320/P340/P370/P400/P401/P405/P485/P505 2SWLPLHUPRGHOWSLFDOPRGOHFRPSDWLELOLW 3IRUFHOOPRGOHV 3IRULSRZHUFHOOPRGOHV 3IRULHUSRZHUDGFHOOPRGOHV 3IRUFHOOPRGOHV 3IRULSRZHUDGFHOOPRGOHV 3IRULYROWDHPRGOHV 3IRULYROWDHPRGOHV 3IRULHUFUUHWPRGOHV 1387 RatedInputDCPower(1)320 340 370 400 405 485 505 W AbsoluteMaximumInputVoltage(Vocatlowetemperature)48 60 80 60 125(2)83(2)Vdc MPPTOperatingRange 8-48 8-60 8-80 8-60 12.5-105 12.5-83 Vdc MaximumShortCircuitCurrent11 10.1 11.75 11 14 Adc MaximumDCInputCurrent 13.75 12.5 14.65 12.5 17.5 Adc MaximumEciency99.5 WeightedEciency98.8 98.6 OvervoltageCategory 28738785123(572132(52370(5&211(&7(7223(57162/5((19(57(5 MaximumOutputCurrent 15 Adc MaximumOutputVoltage 60 85 Vdc 28738785167132(52370(56&211(&7()52062/5((19(57(52562/5((19(57(52)) SafetyOutputVoltageperPowerOptimizer 1±0.1 Vdc 6715&203/1&( EMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(classIIsafety),UL1741 Material UL94V-0,UVResiant RoHS 167//72163(&)&7216 MaximumAllowedSyemVoltage 1000 Vdc Compatibleinverters AllSolarEdgeSinglePhaseandThreePhaseinverters Dimensions(WxLxH)129x153x27.5/5.1x6x1.1 129x153x33.5/5.1x6x1.3 129x153x29.5/5.1x6x1.16 129x159x49.5/5.1x6.3x1.9 129x162x59/5.1x6.4x2.3 /in Weight(includingcables)630/1.4 750/1.7 655/1.5 845/1.9 1064/2.3 gr/lb InputConnector MC4(3)SingleordualMC4(3)(4)MC4(3) InputWireLength 0.16/0.52 m/ft OutputWireType/ConnectorDoubleInsulated/MC4 OutputWireLength 0.9/2.95 1.2/3.9 m/ft OperatingTemperatureRange(5)-40-+85/-40-+185 ˚C/˚F ProtectionRating IP68/NEMA6P RelativeHumidity 0-100 (1)RatedpowerofthemoduleatSTCwillnotexceedtheoptimizer“RatedInputDCPower”.Moduleswithupto+5%powertoleranceareallowed(2)NEC2017requiresmaxinputvoltagebenotmorethan80V(3)ForotherconnectortypespleasecontactSolarEdge(4)FordualversionforparallelconnectionoftwomodulesuseP485-4NMDMRM.InthecaseofanoddnumberofPVmodulesinonering,inallingoneP485dualversionpoweroptimizerconnectedtoonePVmodule.Whenconnectingasinglemodulesealtheunusedinputconnectorswiththesuppliedpairofseals.(5)Forambienttemperatureabove+85°C/+185°Fpowerde-ratingisapplied.RefertoPowerOptimizersTemperatureDe-RatingTechnicalNoteformoredetails. 396VWHPHVL8VLD6RODU(GHYHUWHU 6LOH3DVH DYH 6LOHSDVH 7UHH3DVHIRU9ULG 7UHH3DVHIRU9ULG MinimumStringLength(PowerOptimizers) P320,P340,P370,P400,P401 8 10 18 P405,P485,P5058 14 MaximumStringLength(PowerOptimizers)25 25 50(8) MaximumPowerperString 5700(6000withSE7600-US-SE11400-US)5250 600012750(10)W ParallelStringsofDifferentLengthsorOrientations RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSDC/DC CONVERTERS CUT SHEET R-102Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT L)PLM VSH05V(SH 2HHOIHHVRODSDHOVHSHHFHFRXOHVV HHHZHDHHHV1RMXVHZRVVRVHDV EXHZRVVRVHDVZGVFDSDEOHRI SSSDHOVIRDRRIDGVRZIDOOVZH HRXREXFNOHDSDHOIDH DOVDHHVXFXDOEDFNERHSHH HVHHVXOV7HHVVXSOISRHF againstbucklingandsafelyandefciently DVIHORDGVRHEXOGVXFXH 7HVXSHRVSDFDSDEO HTXHVIHZHRRIDDFHV HGXFHXEHRIRRI SHHDRVDGHDRX RIVDOODRH DODO -VLHIPSPaPNL 6ORSHGRRIVHHDHERHFDODGODHDO IRFHVRRXDOVZFFDFDXVHHREHGDGZV7HFXHGVDSHRIDOV VVSHFDOOGHVHGRFHDVHVHER GHFRVZOHHVVHZV7VXTXH IHDXHHVXHVHDHVHFXGXHHH ZHDHDGDORHVVHOIHH VTWHPISLP-SH7PL9VVM RRI0RXXOHV DOVDORZRSRDO DOORHDDFHV tosecuresystemsush DDVHVGHDORRIV VVPV9LPH4HLPHS DOVDH FRSDEOHZ ODVRRDG RHSFHGRRI DDFHV ,RGHRIIHV DDHRIOOH optionsforat RRIRX DSSOFDRV OODOVDHDGHRIVHHV DOXXDOORHSRHFHGZD anodizednish.Anodizingpreventssurface DGVXFXDOFRRVRZOHDOVRSRG DRHDDFHDSSHDDFH 99HPS-HTPS TheXRRailFamilyoffersthestrengthofacurvedrailinthreetargetedsizes.Eachsizesupportsspecic GHVORDGVZOHDHDOFRVVHSHGRRXORFDRHHVDDORDF 0V9PNL0(SSPNLLLPPPVPNLVTVHSS MVTVLPMVTHPVLPV L)PLM 9HPSLSLPV 7HDEOHEHORZZDVSHSDHGFRSODFHZDSSOFDEOHHHHFRGHVDGVDGDGV9DOXHVDH EDVHGRHIROORZFHD6&*DEOHRRIOXV0RXRRIRHVHSRVXHRRI Slopeof8to20degreesandMeanBuildingHeightof30ft.VisitIronRidge.comfordetailedcerticationletters. 3VH9HPSWH V7-P47 1RH 999 9 VHXODHHVGHDO RXDO,VXSSRVDDHRI ZGDGVRZFRGRVZOHDOVR DVSDVXSRIHH 10’spanningcapability HDORDGFDSDEO Clear&blackanodizednish ,HDOVSOFHVDDODEOH 9 XR10isasleek,low-prolemounting DOGHVHGIRHRVZOR RVRZ,DFHHVVSDVXSRIHH ZOHHDODGHFRRFDO 6’spanningcapability 0RGHDHORDGFDSDEO Clear&blackanodizednish ,HDOVSOFHVDDODEOH 9 VDHDZHDR solarmountingrails.It’sbuilttohandle HHHFODHVDGVSDVXSR IHHIRFRHFDODSSOFDRV 12’spanningcapability HHORDGFDSDEO Clearanodizednish ,HDOVSOFHVDDODEOH RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-103Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT I nT8MTIRRMTMISIGRRSTSGTT 38I TGRRGT3GTGR VisitourwebsiteformanualsthatincludeUL 2703ListingandFireRatingClassication. -T8MIS EngineeringCerticationLetters Weoffercompleteengineeringresources andpre-stampedcerticationletters. -T8MIS ,WTRQ7T GGSRV ThenewUL1703standardintroducestheconceptofa PVmoduletype,basedon4constructionparameters and2reperformanceparameters.Thepurposeof thisclassicationistocertifymountingsystemswithout needingtotestitwitheverymodule. Whatroongmaterialsarecovered? Allreratedroongmaterialsarecoveredwithinthis certicationincludingcompositionshingle,clayand cementtile,metal,andmembraneroofs. GGGRGPIT TWRG Generally,olderroofswilltypicallybe“grandfathered in”,andwillnotrequirere-roong.However,if50%or moreoftheroongmaterialisreplacedforthesolar installationthecoderequirementwillbeenforced. Whereisthenewreratingrequirementcodelisted? 2012IBC:1509.7.2Fireclassication.Rooftop mountedphotovoltaicsystemsshallhavethesamere classicationastheroofassemblyrequiredbySection 1505. GRG,8GTMW ThegeneralrequirementforroongsystemsintheIBC referstoaClassCrerating.ClassAorBisrequiredfor areassuchasWildlandUrbanInterfaceareas(WUI)and forveryhighreseverityareas.Manyoftheseareasare foundthroughoutthewesternUnitedStates.California hasthemostClassAandBroofreratingrequirements, duetowildreconcerns. GTGSIRGSVI Midclampsandendclampsareconsideredpartofthe PV“system”,andarecoveredinthecertication. Whatattachmentsandashingsaredeemed ISVGRRG Attachmentsandtheirrespectiveashingsarenot constituentsoftheratingatthistime.Allcode-compliant ashingmethodsareacceptablefromarerating standpoint. GSTTMMGIIVGR ULretestingwasperformedwithagapof5”,whichis consideredworstcaseinthestandard.Therefore,the ratingisapplicabletoanymoduletoroofgap. AmIrequiredtoinstallskirtingtomeetthere I No,IronRidgeachievedaClassAreratingwithoutany additionalrackingcomponents. WhatdeterminesFireClassication? FireClassicationreferstoare-resistancerating systemforroofcoveringmaterialsbasedontheirability towithstandreexposure. ClassA-effectiveagainstseverereexposure ClassB-effectiveagainstmoderatereexposure ClassC-effectiveagainstlightreexposure GITMTRGG TheIronRidgeClassAratingwillnotdiminishthere ratingoftheroof,whetherClassA,B,orC. Whattiltsisthetiltmountsystemreratedfor? Thetiltmountsystemisratedfor1degreesandupand anyrooftomodulegap,ormountingheight. I GIQMT Allroongproductsaretestedand classiedfortheirabilitytoresistre. Recently,thesereresistancestandards wereexpandedtoincludesolarequipment aspartoftheroofsystem.Specically,this requiresthemodules,mountinghardware androofcoveringtobetestedtogetheras asystemtoensuretheyachievethesame reratingastheoriginalroofcovering. Thesenewrequirementsarebeingadopted throughoutthecountryin2016. IronRidgeCertication IronRidgewastherstcompanyto receiveaClassAFireRating—thehighest possiblerating—fromIntertekGroupplc.,a NationallyRecognizedTestingLaboratory. IronRidgeFlushMountandTiltMount Systemsweretestedonslopedandat roofsinaccordancewiththenewUL1703 &UL2703teststandards.Thetesting evaluatedthesystem’sabilitytoresist amespread,burningmaterialand structuraldamagetotheroof. Refertothetablebelowtodeterminethe requirementsforachievingaClassAFire Ratingonyournextproject. 9V 9RG3R SolarmodulesaregivenaType classicationbasedontheir materialsandconstruction. 3TTM9S Mountingistestedaspartofa systemthatincludestype-tested modulesandre-ratedroofcovering. 8TM Roofcoveringproductsaregivena FireClassRatingofA,BorCbasedontheirtestedreresistance. Aburningwoodenblockisplacedonmoduleasafanblowsat12mph. Flamecannotbeseenonundersideofroofwithin90minutes. TTMGT Flameatsouthernedgeofroofisaimeduptheroofasafanblowsat12 mph.Theamecannotspread6feetormorein10minutes. 9VG,RGS ,TM6I 9S 89RV3R,8GTM FlushMount AnySlope Type1,2,&3 TiltMount ≤6Degrees Type1,2,&3 *ClassAratedPVsystemscanbeinstalledonClassA,B,andCroofs. KN RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-104Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT KN SimpliedGroundingforEveryApplication 72IDPLORIFRPSRVOLPLDVGIRU VSDUDURXGLDUGDUEERGLVRODUPRGXOV GLUFOR,UR5LG55DLOVOOVVPSVDIDXU 2IDPLOOXV0RX7LO0RXDGURXG 0RXDUIXOOOLVGR/VDGDUG 2DUGDUIRUPVVFXUOFULFDOERGVLER PRGXODGUDLOUVXOLLPDSDUDOOOURXGL SDVURXRXVVP7LVODGVRVDIUDGPRU UOLDEOLVDOODLRV 2DPLORIRPSRV UniversalFasteningObject(UFO) 72VFXUOERGVVRODUPRGXOVR5 5DLOV,FRPVDVVPEOGDGOXEULFDGDG cantawiderangeofmoduleheights. StopperSleeve 76RSSU6OVDSV RR2FRULLLR DERGGGFODPS BondedSplice DFRGG6SOLFXVV VOIGULOOLVFUVRIRUP DVFXUFRFLR1R ERGLVUDSGG BondedAttachments 7ERGLERODDFV DGERGV/IRRR UDLO,LVLVDOOGL VDPVRFNDVUVRI VVP GroundingLug VLOURXGL/X FRFVDLUUR RI3PRGXOVRURXGLFRGXFRU SystemDiagram ULCertication 7,UR5LGOXV0RX 7LO0RXDGURXG0RX 6VPVDEOLVGR/ E,UNURXSSOF /LVVDGDUGIRU DOXDLVRODUPRXL VVPV,VXUVVGLFV LOOPDLDLVUROFULFDODG PFDLFDOFRFLRVRU DGGSULRGRILPL UPRXGRRULURPV ©2016IronRidge,Inc.Allrightsreserved.Visitwww.ironridge.comorcall1-800-227-9523formoreinformation.Version1.10 Cross-SystemCompatibility Feature FlushMount TiltMount GroundMount LO52O RSSU  RGGSOLF1 URXGL/XSU5RSU5RSUUUD LFURLUU RUSLPLU SDV000 DUIR0,0, 6RODUG3333333 LULODVVODVV1 RGXO7VGRUDOXDGLRUUDPG0RGXOV 5IURLVDOODLRPDXDOVIRUDGDLOGOLV í SSURGSDVPLFURLUUVFDSURLGTXLSPURXGLRI,UR5LGVVPVOLPLDLGIRU groundinglugsandeldinstalledequipmentgroundconductors(EGC).Aminimumoftwomicroinvertersmountedtothe VDPUDLODGFRFGRVDPDFDEOLVUTXLUG5IURLVDOODLRPDXDOVIRUDGGLLRDOGDLOV GotoIronRidge.com/UFO RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-105Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT nT8OTIRROOOOTOISIRRSOTSOTOT IO TRROT, Testing&Certication StructuralCertication DesignedandCertiedforCompliancewiththeInternationalBuildingCode&ASCE/SEI-7. WaterSealRatings :DWU6DL7WWR/6FWLR5DL7WD76:LUL5DL7W,WUW 5DWLDSSLFDIRUFRSRLWLRLURRIDLRSWD ConformstoUL2703MechanicalandBondingRequirements.SeeFlushMountInstallManualforfullratings. AlignmentMarkers Quicklyaligntheashingwithchalklinestondpilotholes. RoundedCorners 0DLWDLUWRDDLUWUWURRIL ReinforcementRibs Helptostiffentheashingandpreventanybendingor FULLULLWDDWLR BenetsofConcentricLoading 7UDLWLRDRDUDWWDFWDD RULRWDRIIWWWUDLDD RWLFLWURFUDRWD RWDFUDSLIWFDSDFLW DRRWLWRSURFWWRDLW UDLDDRW7LFRFWULFRDL LUWLDWURUDWWDFWIRU WW IO 9TISTOT9R ,UR5LDRRWUDLWDULRDUURRI SURWFWLR7LTDWUDLLRW DWDFDSDWLULUDWDU RISURWFWLRDDLWDWULWULR,DLWLRW WLWRDSSUIFWDLWUDLDWWDFWLWW DRWWRDLLFDLFDWUW DRRW O5TV DRRWLTDSLFDSDW WDRWDRFLWRSDFLWDLS WLW7DSSDRRWLU SULRUWUFWUDWUWDLL WUDLDDRWLDFRFWULF RDSDW 9OTR9I9O FWRLDRWDRRWRLWDDRRWLW WDRFWL RRWU0RW 6WFRSRW O9R DRRWDDUFLWFWUWLLWU DURISURWFWLRDWSDWIRU LUWDWUDDLDWDFRIU FRSRWUDLWDDWLULF 7DLWIFDSDWW Cap.FlashFoot2istherstsolarattachment WRSDW76:LUL5DL7W 9OTOT DWSDWIRULUWDWU DDIURWDWUDRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-106Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com GFT-OP-11a (24-MAR-2014)© 2019 IronRidge, Inc. FlashFoot2 Certification Letter - 1 28357IndustrialBlvd. Hayward,CA94545 1-800-227-9523 IronRidge.com Attn: CoreyGeiger,COO,IronRidgeInc. Date: September 5th, 2019 Re: Structural Certification for the IronRidge FlashFoot2 This letter addresses the structural capacity of the IronRidge FlashFoot2 (FF2) component for use as a roof attachment for PV solar systems. FF2 is composed of an aluminum Cap, a 9” x 12” aluminum flashing, and an aluminum stabilizing base. The flashing component is attached to an underlying roof rafter using a 5/16” lag bolt. The assembly details are shown in Exhibit EX-0013. The referenced uplift and lateral resistance of FF2 is based on structural tests conforming to ASTM D1761-12 “Standard Test Methods for Mechanical Fasteners in Wood.” Testing was performed by installing a FF2 component on a sample roof deck composed of composition shingles covering ½” OSB Board over a 2x4 Douglas Fir rafter as shown in Figure 1. The moisture content and specific gravity of the rafter was measured and recorded per ASTM D2395-14 “Standard Test Methods for Density and Specific Gravity (Relative Gravity) of Wood and Wood-Based Materials.” The moisture content for uplift test samples was between 8% and 15% with an average specific gravity of 0.54. The moisture content for lateral test samples was 13% with an average specific gravity of 0.54. The critical failure mode observed for both the uplift and lateral tests was pullout of the 5/16” lag screw from the rafter. The average peak loads recorded at the critical failure point for the uplift and lateral tests were 3203 lbs. and 1237 lbs., respectively. A safety factor of 3.0 was applied to certify the allowable uplift capacity to 1067 lbs. and the allowable lateral capacity to 412 lbs. for a substrate with a specific gravity of 0.54. For rafter wood species with specific gravity other than 0.54, the allowable uplift capacity shall be adjusted by a factor of �05432 per AP&PA National Design Specification Eq. (12.2-1), and the allowable lateral capacities shall be adjusted per the equation −− from APA Engineering Wood Construction Guide APA 2011 (G is wood specific gravity). For the common wood species, the allowable capacities are provided in Table 1. t h , , W W d dd s RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-107Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT 4.5in 3.0in 9.0in 12.0in 3.6in 3.7inSTABILIZINGBASE 2 1 3 4 FlashFoot2Capcanbeinstalledineitherorientationshown EXHIBIT:EX-0013 ITEMNO.DESCRIPTION 1 ASSY,FLASHING,MILLORBLACK 2 ASSY,CAP,MILLORBLACK 3 BOLTLAG5/16X4.75" 4 WASHER,EPDMBACKED ASSY,FLASHFOOT2 DWG.NO.EX-0013 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-108Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-109Current Solar LLC.-3000 Altamesa Blvd, Suite 300Fort Worth, tx 76133(817) 690-145611.730Burchett, Larry2910 Harbor RefugeSouthlake, TX 7609202/23/2021SUBMIT FOR PERMIT