Loading...
SB Item 7 - Plans84.00 39" Five Below Sign Type: Illumination: Square Footage: SIGN A Internally Illuminated LED Individual Channel Letters on backer E Southlake Blvd Gateway Plaza 2910 E Southlake Bouolevard Southlake, TX 76092-6616 SIGN A 11 120946 Robert Young Kirk Forster 02/05/2021 Five Below Gateway Plaza 2910 E Southlake Blvd. Southlake, TX 76092-6616r Project ID#: Project Mgr: Designer: Created on: apexsigngroup.com R1 02/23/21 KF - Updated Sign A to be on backer R2 03/03/21 MD Updated per redline comments R3 04/08/21 MD Updated sign A to 39” on 42” backer, removed construction sign E H w y 1 14 Sign Type: Square Footage: Five Below 3/16” White Polycarbonate Panel w/ first surface applied Vinyl Graphics 14.76 SIGN C Sign Type: Square Footage: Five Below 3/16” White Polycarbonate Panel w/ first surface applied Vinyl Graphics 14.00 SIGN B SIGN C SIGN B Landlord Document Review _____ Concept Approved As Noted _____ Not Approved - Revise & Resubmit •The concept approval granted herewith is for design intent only. •Tenants and their contractors are fully responsible for compliance with all Federal, State, Local Codes & Ordinances, and the Design Review Board (Association) as well as compliance with Lease Agreements for this project. •All work must be free of hazardous materials of any kind. •UL labels shall not be visible to the public view. Termination of electrical service shall be hidden from public view. •Contact the Center's Property Manager to arrange for installation of signage, which should not interfere with Center’s open and operating tenants. •Mounting - all penetrations to be in mortar joints ONLY and NOT Through the brick and sealed water-tight. •Display of banners, flags, pennants, streamers, balloons, and inflatables are not allowed unless granted per Lease agreement or written authorization from Landlord. •If you do not have any rights to the Center's monument and/or pylon sign, per the Lease, you will need to request permission from your Center's Property Manager. By: __________________________________________ Brant Mullen, Sr. Tenant Coordinator Date Retail Properties of America Inc. 972-801-6008 or mullen@rpai.com 4/28/21 22 120946 Robert Young Kirk Forster 02/05/2021 Five Below Gateway Plaza 2910 E Southlake Blvd. Southlake, TX 76092-6616r Project ID#: Project Mgr: Designer: Created on: apexsigngroup.com R1 02/23/21 KF - Updated Sign A to be on backer R2 03/03/21 MD Updated per redline comments R3 04/08/21 MD Updated sign A to 39” on 42” backer, removed construction sign Allowable Square Footage this Elevation:115.00 Formula: MAX letter height 42”, 115.00 SqFt Allowable Actual Square Footage this Elevation:84.00 DRAWINGS ARE FOR LEASE PURPOSES ONLY. ALL MEASUREMENTS TO BE FIELD VERIFIED PRIOR TO FABRICATION. Front Elevation (South) Scale: 3/32” = 1’-0" 82'-0" Lease Dimension Facade: - FB to engineer new storefront glass, 10’- 6” high, 4’-0” min panel width, no upper mullions. To be approved in TT’s finish out plans. Provide LL with spec and location - FB to locate 8’ tall storefront doors per tenant’s final plans. To be approved in TT’s finish out plans. Provide LL with spec and location - FB to install walkway lighting, 6’-0” min O.C., with additional door light To be approved in TT’s finish out plans. Provide LL with spec and location - Existing curb cut within 30’ of entry - LL to provide unobstructed permanent access to sign mountable/ electrical connection area - LL to provide electrical to center of all applicable sign mountable areas Signage: - Primary Sign: 39” internally illuminated channel letters on backer frame - Pylon Panel: LL to provide tenant with a sign panel on the common pylon sign. If a panel is not available, tenant has the right to take an open panel when available. 84.00 39" Five Below Sign Type: Illumination: Square Footage: SIGN A Internally Illuminated LED Individual Channel Letters on backer 23’-0” 39 " 24’-0” 42 " NOTES FOR ALL BUILDING SIGNS: •ALL PENETRATIONS TO BE WITHIN MORTAR JOINTS ONLY, sign company to site survey façade and submit template to LL for approval, showing brick/mortar pattern and placement of mounting hardware prior to fabrication. •Tenant and sign company are responsible for cleaning the façade, windows, sidewalks, awnings/canopies of any residue/debris from installation and repairing any damage to premises. •Installation to occur before or after business hours, coordinate with property management for specific times, and shall not block any drive aisles. •Installation shall be supervised by LL Team to ensure correct placement and specs of signage, schedule with LL Team (typically between 8 and 10 am). •Center sign vertically and horizontally within sign band. •No visible electrical equipment or structural elements allowed, including but not limited to: conduit, transformers, wiring, angles, bolts, brackets, angle iron, Unistrut, etc. (incl. on roof or rear of parapet). •Core drilling is to be from the exterior to the interior to prevent spalling. •Utilize existing penetrations where possible. •Minimize number and size of penetrations in wall. •Seal all, old and new, penetrations in walls and paint to match. •Utilize and conceal non-corrosive mounting hardware/fasteners. •Any stickers, U.L labels, etc. are not to be visible from ground, if not possible, sticker(s) color shall match sign. •Tenant is responsible for removing signage, cleaning facade, and patching all penetrations to match existing façade/mortar/brick colors, texture(s), materials, conditions, etc. to like-new condition. •Tenant may be required to remove and replace signage if not installed per LL’s approval. •Any disconnect switch to be a part of signage, letters or wireway(if applicable). If not possible, shall be in a concealed location as possible, including within premises. •Remove all existing j-boxes, conduit, goose-neck lights, etc. remaining from previous tenant. •Sign installation company may be required to submit a refundable security deposit. •Halo lit standoffs to be painted to match building color and to be no more than 2”, electrical wiring to be in conduit (not exposed to the elements). •All rear doors (new or existing) to be repainted to match existing building color and rust on hinges to be removed. •Front and rear doors are to be labeled with TT’s address/suite number. Front label(s) to be property specific location, size, font, and color(s). Rear to be 4” black Arial in vinyl, centered horizontally, with its centerline at 60” from bottom of door (or A.F.F.). Main rear door to have Tenant’s name/DBA, all text and graphics to be approved by LL as part of the signage package. •Nothing to be attached to the storefront system. If LL allows, items maybe suspended from wall soffit or furring only. _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 4/28/21 33 120946 Robert Young Kirk Forster 02/05/2021 Five Below Gateway Plaza 2910 E Southlake Blvd. Southlake, TX 76092-6616r Project ID#: Project Mgr: Designer: Created on: apexsigngroup.com R1 02/23/21 KF - Updated Sign A to be on backer R2 03/03/21 MD Updated per redline comments R3 04/08/21 MD Updated sign A to 39” on 42” backer, removed construction sign _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 4/28/21 1. Existing Facade: To be determined 2. 0.063” Aluminum letter returns painted to match silver 3. ) bonded to face, #8 pan head screws to returns. Note: 2” trimcaps for 1” trim cap (silver letters 54” and larger .125” ACM backs (pre-finished white) fastened to returns. Seal w/ VOC compliant 360 white 4. latex caulk to prevent moisture penetration. (interior of sign can ptd white for max illumination) 5. White LED's (Principal) 6. 3/16” White Acrylic faces 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 8. Primary electrical feed in UL conduit / customer supplied UL junction box 9. Power Supplies within UL enclosure (removable lid), 1/4” x 1” min screws 10. Mounting Hardware to suit, All penetrations to be in mortar joints or use existing. 11. .125” aluminum face welded to 2” x 2” aluminum angle perimeter frame, weld and grind smooth. Angle returns and border of face painted white, center area ptd to match PMS #2945C Blue. Countersunk screws (ptm returns) thru pre-drilled holes in frame thru to 2” x 2” aluminum angle mounting clips Specifications: Channel Letters on Backer / Frame 84.00 39" Five Below Sign Type: Illumination: Square Footage: SIGN A Internally Illuminated LED Individual Channel Letters on backer White LED's (Principal) (X) 60 W Power Supplies Total amps: X.XX (1) 120v/ 20 amp circuit required Electrical Detail: General Notes: This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. - Grounded and bonded per NEC 600.7/NEC 250 - Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps - Sign is to be UL listed per NEC 600.3 - UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer. For multiple signs, a disconnect is permitted but not required for each section - The location of the disconnect switch after installa- tion shall comply with article 600.6 (A) (1) per NEC Note: - Butt seams will be required (>12’ lengths) - Backer frame will be manufactured in sections as necessary for shipping and install. (sections to be 20’-0” or less) 5”2” 2 3 9 10 1 7 8 4 5 6 Scale: N.T.S. Se ct ion @ LE D Ch anne l L et t er 11 ¼” Drain holes at bottom of letter cans w/ light baffles. For exterior signage only 44 120946 Robert Young Kirk Forster 02/05/2021 Five Below Gateway Plaza 2910 E Southlake Blvd. Southlake, TX 76092-6616r Project ID#: Project Mgr: Designer: Created on: apexsigngroup.com R1 02/23/21 KF - Updated Sign A to be on backer R2 03/03/21 MD Updated per redline comments R3 04/08/21 MD Updated sign A to 39” on 42” backer, removed construction sign Scale: 1/4" = 1'-0" Sign Layout Detail 23’-0”276" 39 " 24’-0”[288”] 42 " _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 4/28/21 55 120946 Robert Young Kirk Forster 02/05/2021 Five Below Gateway Plaza 2910 E Southlake Blvd. Southlake, TX 76092-6616r Project ID#: Project Mgr: Designer: Created on: apexsigngroup.com R1 02/23/21 KF - Updated Sign A to be on backer R2 03/03/21 MD Updated per redline comments R3 04/08/21 MD Updated sign A to 39” on 42” backer, removed construction sign 6'-9"17'-7 1/2" 4' - 0 " 4' - 0 " 6'-9" 4' - 0 " Awning material stapled into track and covered with rubber trim D1 D2 D3 Awning Layout Details Scale : 1/4” = 1’-0” 2 3 4 TBD 1. Existing Facade: XXXX 2. Awning Material: Sunbrella #6017 “Royal Blue” 3. 1” x 1” x 0.125” Aluminum square tubing frame painted blue to match the awning material SW#6959 Blue (wire brush all welds) 4. Open Sides & Bottom 5. Mounting hardware to suit Specifications: 5 Typical Support Detail: Rustproof self tapping #12 x ¾” TEC screws 1” x 1” x 1/8” aluminum tubing ( awning frame ) Hot-dipped galvanized 12 ga. sheet metal mounting clip 1 1/2" 2 " Mounting hardware to suit Stapled to Frame Awning Non-IlluminatedIllumination: Type: AWNINGS D 48" Slant Style Awning Section Detail Scale : N.T.S. 1 _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 4/28/21 Awnings are not a part of this Sign Variance Request 66 120946 Robert Young Kirk Forster 02/05/2021 Five Below Gateway Plaza 2910 E Southlake Blvd. Southlake, TX 76092-6616r Project ID#: Project Mgr: Designer: Created on: apexsigngroup.com R1 02/23/21 KF - Updated Sign A to be on backer R2 03/03/21 MD Updated per redline comments R3 04/08/21 MD Updated sign A to 39” on 42” backer, removed construction sign Panel Replacement- Existing (D/F) Pylon Scale: 1/2” = 1’-0”QTY 2 (1 SET) Sign Type: Square Footage: Five Below 3/16” White Polycarbonate Panel w/ first surface applied Vinyl Graphics 14.00 SIGN B 1.New 3/16" White Polycarbonate Panel 2. New Vinyl to match; Arlon Blue#2500-67 3. Existing 2” Retainers & Divider Bar Specifications: Proposed 1 2 3 Scale: 1” = 1’-0” Temporary Graphic Detail Temporary & removable low-tac vinyl. Applied to upper left of panel at visual opening. Inset graphic 2” in from edge of panel (each way) Pantone Yellow C Black 12” 12 ” 76 1/4” 111” VO 115” Cut 10 3 / 4 ” 13 1 / 2 ” V O 17 1 / 2 " C u t see LL's temporary signage criteria _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 4/28/21 77 120946 Robert Young Kirk Forster 02/05/2021 Five Below Gateway Plaza 2910 E Southlake Blvd. Southlake, TX 76092-6616r Project ID#: Project Mgr: Designer: Created on: apexsigngroup.com R1 02/23/21 KF - Updated Sign A to be on backer R2 03/03/21 MD Updated per redline comments R3 04/08/21 MD Updated sign A to 39” on 42” backer, removed construction sign Proposed Sign Type: Square Footage: Five Below 3/16” White Polycarbonate Panel w/ first surface applied Vinyl Graphics 14.76 SIGN C Panel Replacement- Existing (D/F) Pylon Scale: 1/2” = 1’-0”QTY 2 (1 SET) 1.New 3/16" White Polycarbonate Panel 2. New Vinyl to match; Arlon Blue#2500-67 3. Existing 2” Retainers & Divider Bar Specifications: 1 2 3 119 3/4” Cut 17 3 / 4 " C u t Scale: 1” = 1’-0” Temporary Graphic Detail Temporary & removable low-tac vinyl. Applied to upper left of panel at visual opening. Inset graphic 2” in from edge of panel (each way) Pantone Yellow C Black 12” 12 ” 10 3 / 4 ” 13 3 / 4 ” V O 115 3/4” VO 76 1/4” see LL's temporary signage criteria _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 4/28/21