Item 9B - PlansOUMII1 GR
HALL LI&W
AS 5e -HEC)
�✓� Approved as Noted (AAN)
2/5/21
LL conceptually approves the blade sign and vinyl
(mural-esque) graphic, however, based on city feedback, a
variance will be needed, as it falls under a mural category. If
avoiding the variance process consider a more sign -like design. WTCOOR PPJN�Ll EXTERIM FAINT FA5TIN$
WALL L15HY GRAVE FgIL VINYL � ,_ POOR t HINPG44
SCONCE LOCATIONS
BrantMullen
RA L Date
486 - WHISTLE BRITCHES - SIDE EXTERIOR
AS+.l. w
11
ouTCOQA
1NALL LNDFR
9WIIT A3 s.GF�O
pL®10H �r Ts+arrr A9 SGI�P
F aWM SEPARAT@ PBRMIT.
rRC7sl'I�E T€l'
povirR
I �
I
I
CUTCOM
WALL L16HT
As 34MP
SIGN LOCATIONS
"t I
" ►LIFE OVER LIKES
4�V1S�1A.1�S: •. �-
PAINT EXI�.TINO
BLADE 51ON BY TENANT AS 51 -HW DOOR d WI OW
ERJOER SEPARATE PERMIT FRAMES AS
PROVIRE ND—E5SARY P® A UNDER SEPARATE PERMIT
51O44AOE BY TENANT AS SCHEp
UNDER SEPARATE PERMIT.
PRCJVIPE NE=CESSARY PC71Vf=R
PAINT EXI5TINO
DOOR 6 WINDOW
FRAMES AS SC.HED;
��U---�NP17Rg�SEPARATE PE. JT
7
ua.
OUTDOOR
OUTDOOR
WALL LIGHT
WALL LIGHT
AS SCHED,
AS SCHEDi
LINVIERUNVER
�
SEPARATE
5EPARATE
PERMIT
PERMIT
I L-105
�t
in
CoORNER POST METAL A5 56HED CORNER POST
AS WHED
SCONCE LOCATIONS
486 - WHISTLE BRITCHES - FRONT EXTERIOR
Landlord Document Review
Concept Approved As Noted FOR PA
Not Approvetl Rev se & Resubm t
-The concept approval granted herew th is for design intent only.
•Tenants and their conhactors are fully responsible for compliance with all Federal, State, Local Codes & Ordinances. and the Design Review Board
(Association) as well as compliance with Lease Agreements for this project
•AII work must be free of hazardous materials of any kind.
•If there is i discrepancy between the plans and the Lease, the Lease shall prevail.
•Itis Tenants responsibility to remove existi� signage (it applicable), patch, repair and repaint the sign faced, area to Ilke-new... color.
•UL labels shall not be visible to the public view. Termination of electoral service shall be hidden from public view.
•Contact the Centers Property Manager to arrange for installation of signage, which should not interfero with Center's open and operating tenants.
•Mounting - all penetrations to be in mortar joints ONLY and NOT Through the brick and sealed water -tight.
•Display of banners, flags, pennants, streamers, balloons, and Inflatables are not allowed unless granted per Lease agreement or written authorization hem
Land cod.
•It you do net have any rights to the Center's monument andlor pylon sign, per the Lease, you will need to request permission from your Centers Property
Manager.
,1t_ 2/5/21
By:
Brant Mullen, Sr. Ten ant Coordinator Dafe
Retail Properties of America Inc.
912-801-8008 or mullen@rpai.com
ALL PENETRATIONS TO BE WITHIN MORTAR JOINTS ONLY,
including all lighting. Sign company to site survey fagade and submit
template to LL for approval, showing brick/mortar pattern and placement
of mounting hardware prior to fabrication.
See signage drawings for more additional signage installation /
fabrication related requirements (ALL PAGES).
Light fixtures and locations are approved.
SIGN LOCATIONS
7
OJ7DOCR
WALL LIGHT
A5 5GHEP
L-IO5
SCONCE LOCATIONS
Approved as Noted (AAN)
2/5/21
Brant Mullen Date
I�RRAI I 486 - WHISTLE BRITCHES - BACK EXTERIOR
p1TDOOR
r" YVALL Ll6rtrf
AS SCHEP
SIGN LOCATIONS
OJrDOOR
WALL LIGHT
516NA&E BY TENANT A5 SIGHED
A5 5C fHZC;
JHCMZ SEPARATE PERMIT.
L-IO5
PROJIPE NECESSARY POMR
IF =1 LA I I
SCONCE LOCATIONS
Approved as Noted (AAN)
2/5/21
Brant Mullen Date
I�RRAI I 486 - WHISTLE BRITCHES - BACK EXTERIOR
p1TDOOR
r" YVALL Ll6rtrf
AS SCHEP
SIGN LOCATIONS
IF =1 LA I I
WT
CD
SCONCE LOCATIONS
Approved as Noted (AAN)
2/5/21
Brant Mullen Date
I�RRAI I 486 - WHISTLE BRITCHES - BACK EXTERIOR
p1TDOOR
r" YVALL Ll6rtrf
AS SCHEP
SIGN LOCATIONS
NOTES FOR ALL BUILDING SIGNS:
-ALL PENETRATIONS TO BE WITHIN MORTAR JOINTS ONLY, sign company to site survey fagade and
submit template to LL for approval, showing brick/mortar pattern and placement of mounting hardware prior
to fabrication.
-Tenant and sign company are responsible for cleaning the fagade, windows, sidewalks, awnings/canopies
of any residue/debris from installation and repairing any damage to premises.
-Installation to occur before or after business hours, coordinate with property management for specific
times, and shall not block any drive aisles.
-Installation shall be supervised by LL Team to ensure correct placement and specs of signage, schedule
with LL Team (typically between 8 and 10 am).
-Center sign vertically and horizontally in sign band / area.
-No visible electrical equipment or structural elements allowed, including but not limited to: conduit,
transformers, wiring, angles, bolts, brackets, angle iron, Unistrut, etc. (incl. on roof or rear of parapet).
-Core drilling is to be from the exterior to the interior to prevent spalling.
-Utilize existing penetrations where possible.
-Minimize number and size of penetrations in wall.
-Seal all, old and new, penetrations in walls and paint to match.
-Utilize and conceal non -corrosive mounting hardware/fasteners.
-Any stickers, U.L labels, etc. are not to be visible from ground, if not possible, sticker(s) color shall match
sign.
-Tenant is responsible for removing signage, cleaning facade, and patching all penetrations to match
existing fagade/mortar/brick colors, texture(s), materials, conditions, etc. to like -new condition.
-When patching/repairing facade, Tenant is responsible for painting & texturing seam to seam, to keep
facade colors consistent and in a first-class state.
-Tenant may be required to remove and replace signage if not installed per LL's approval.
-Tenant to provide adequate blocking behind any EIFS to provide structural stability for all signage and
exterior modifications.
-Any disconnect switch to be a part of signage, letters or wireway(if applicable). If not possible, shall be in
a concealed location as possible, including within premises.
-Remove all existing j -boxes, conduit, goose -neck lights, etc. remaining from previous tenant.
-Sign company may be required to submit a refundable security deposit.
-Mount below roof deck (preferred), if not possible, do not penetrate roof membrane/flashing and seal
penetrations on both sides.
oUtilize LL required roofer to seal electrical service penetration/s (via pitch pan/weatherhead)
oWiring to be in conduit and run in a straight, organized, and clean manner
oPaint all equipment and conduit to match parapet color
oConduit not to be run along parapet
-Halo lit standoffs to be painted to match building color and to be no more than 2", electrical wiring to be in
conduit (not exposed to the elements).
•AII window lettering to be raised applied (1/4" min. FCO), apply vinyl to interior glass face to mirror letters
and hide adhesive.
•AII rear doors (new or existing) to be repainted to match existing building color and rust on hinges to be
removed.
-Front and rear doors are to be labeled with TT's address/suite number. Front label(s) to be property
specific location, size, font, and color(s).
-Nothing to be attached to the storefront system. If LL allows, items maybe suspended from wall soffit or
furring only.
Minimum Letter Requirements
-Letters to be individual 5" (no larger) deep aluminum channel letters/logo (reverse halo lit is acceptable at
3" with no more than 2" offsets)
•<24" channel letters/logos aluminum .040 sides & .063 backs (fronts when halo lit)
•<24" to have 1/8" thick acrylic faces(s) min.
Landlord Document Review
��
F� P� I
Concept Approved As Noted
Not Approved - Revise & Resubmit
-The concept approval granted herewith is for design intent
only.
-Tenants and their contractors are fully responsible for
compliance with all Federal, State, Local Codes & Ordinances,
and the Design Review Board (Association) as well as
compliance with Lease Agreements for this project.
•AII work must be free of hazardous materials of any kind.
-If there is a discrepancy between the plans and the Lease, the
Lease shall prevail.
-It is Tenant's responsibility to remove existing signage (if
applicable), patch, repair and repaint the sign facade area to
like -new condition.
-UL labels shall not be visible to the public view. Termination of
electrical service shall be hidden from public view.
-Contact the Center's Property Manager to arrange for
installation of signage, which should not interfere with Center's
open and operating tenants.
-Mounting - all penetrations to be in mortar joints ONLY and
NOT Through the brick and sealed water -tight.
-Display of banners, flags, pennants, streamers, balloons, and
inflatables are not allowed unless granted per Lease agreement
or written authorization from Landlord.
-If you do not have any rights to the Center's monument and/or
pylon sign, per the Lease, you will need to request permission
from your Center's Property Manager.
Bv: (R47 2/5/21
Laura Pacino, Tenant Coordinator Date
Retail Properties of America Inc.
630-634-4283 or pacino@rpai.com
Approved as Noted (AAN)
2/5/21
Brant Mullen Date
rdRPAI.
Z.■ ,'_
f '� e
42H
ISTLE B IT
rill CHICKEN BISCUITS • BEER
Vim
Sign centering
is a little los
_ = 1
� ' Z
F
LED halo illuminated channel letters. Faces to have holes to represent light bulbs, holes backed
with white acrylic. Letter to stud mount directly to building facade.
i
137 1/8"
N
M .1"�,
�y
Approved as Noted (AAN)
2/5/21
Brant Mullen Date
End RISAI
Halo illuminated channel letters
painted white, stud mount into
mortar joints. Wiring holes to
penetrate mortar joints as well.
Studs and wiring to be covered
with sleeving painted building color.
1/2" thick stud mount, painted
acrylic letters for
"CHICKEN BISCUITS BEER"
Tagline shall also only penetrate in mortar joints.
1371/811
QENOFNi
2E U ag y
a
Front Elevation UL Listed
o ° 0
Remote m
LED trans
enclose
aluminum channel letter routed face with
welded returns
GE nb100 LED modules
thick clear polycarbonate back, painted
)w different colored halo
ant from the face color)
vall secured with silicone
Approved as Noted (AAN)
rj ri — 2/5/21
Brant Mullen Date
End R PA I
9-1/2"
BRICK I MORTAR
DIMENSIONS TO BE
CONFIRMED
THIS IS AN APPROXIMATION OF STUD / WIRING HOLE LOCATIONS. FINAL PLACEMENT WILL BE DETERMINED AFTER SITE SURVEY IS TAKEN
D.
C IJ Ll M LIKE IJV ° M S C U F TS ° BEER
• - STUD HOLES
0 -WIRING HOLES
Confirm the pattern still matches and
adjust standoffs and power supply
locations as required to be in mortar
joints, since the sign as shown needs to
be centered as marked up on elevation.
Approved as Noted (AAN)
2/5/21
Brant Mullen Date
rdRISAI
ALL PENETRATIONS TO BE
WITHIN MORTAR JOINTS ONLY.
LED illuminated routed face blade sign
Routed copy backed with acrylicdriver
---
I� 'I
I�x x�l
C)TD =1
i
1= =1
• (y)l
x x
I, ,I
3I-1 1 /2" Routed copy with
push thru acrylic
W&VA1112191
Front Elevation
12V LED
modules
QENOENt
2�
rt L
UL Listed
Approved as Noted (AAN)
Brant Mullen
End F
Approved as Noted (AAN)
2/5/21
Brant Mullen Date
End RISAI
11'-5 1/8"
\ D D CJ H , T
N
Halo illuminated channel letters
painted white, stud mount.
1/2" thick stud mount, painted
acrylic letters for
"CHICKEN BISCUITS BEER"
Paint sleeved standoffs
to match the building.
Rear Elevation
QfNOENi i19
?E U 9
a
sC O
UL Listed
Remote m
LED trans
enclose
aluminum channel letter routed face with
welded returns
GE nb100 LED modules
thick clear polycarbonate back, painted
)w different colored halo
ant from the face color)
vall secured with silicone
%j- tv
It a hat
h .w
amu.