Item 6GS0UTHLA1<.,,E
PLANNING & DEVELOPMENT
SERVICES
STAFF REPORT
April 13, 2021
CASE NO: ZA21-0018
PROJECT: Site Plan for GMI Phase II
EXECUTIVE
SUMMARY:
DETAILS
Case No.
ZA21-0018
Claymoore Engineering, is requesting approval of Site Plan for the GMI Phase II
on property described as Tract 11 E, Thomas Easter Survey Abstract No. 474, an
addition to the City of Southlake, Tarrant County, Texas, and located at 2450
Crooked Lane, Southlake, Texas. SPIN Neighborhood #8.
The property is located at the northwest corner of the intersection of S. Nolen Drive
and Crooked Lane.
The purpose of this request is to seek approval of a Phase II site plan for the
development to construct 3 flex light industrial/corporate office buildings totaling
approximately 58,780 square feet located on approximately 5.72 acres. The
proposed site access is from S. Nolen Drive, a driveway north to the future Village
Center Drive connection to S. Nolen Drive and S. Kimball Avenue, and two
driveway access points west into the Kimball Heights and Pinnacle Point
commercial developments to S. Kimball Avenue. The applicant is providing a 5 -
foot sidewalk along the west side of S. Nolen Drive and a 6 -foot sidewalk on the
west side of Crooked Lane.
Site Data Summary
Approved Phase 1
Proposed Phase 2
Site Plan
Site Plan
ZA20-0040
ZA21-0018
Current Zoning
S -P-2
S -P-2
Land Use Designation
Mixed Use
Mixed Use
Acreage
7.12
5.74
Number of Lots
1
3
Total Building Floor Area
79,500 sf
58,780 sf (3 bldgs.)
(Gross)
Floor Area by Use:
Industrial
57,000 sf
General Office
22,500 sf
Max. Building Height/
35 ft. / 2
35 ft. / 1 story
Number of Stories
Open Space %
37%
31%
Area of Impervious Coverage
203,113 sf
185,586 sf
Impervious Coverage %
65%
74%
Total Parking Required (S -P-
133
196
2
Total Parking Spaces
167
258
Provided
The previously approved "S -P-2" development regulations (ZA20-0040) based
on the 1-1" Light industrial District Regulations with the following exceptions:
Regulation
Standard 1-1" District
"S -P-2" Regulation
1. To facilitate a contiguous development,
1. Bufferyards shall be located
buffer yards will not be required along
within and along outer and inner
internal boundary lines.
perimeter of a lot or boundary
2. Requires a F-2 bufferyard and
2. Section 42.4.f establishes a F-2 buffer
8 -ft. masonry fence along south
yard and requires a masonry fence. A
boundary adjacent to residential
masonry fence will not be provided for the
F-2 Buffer along the south property line
zoning.
adjacent to residential zoning.
3. Requires a F-1 bufferyard and
8 ft. opaque fence along the
3. Section 42.4.f establishes a F-1 buffer
Bufferyards
west property line.
yard requires an 8' opaque fence. A
minimum 8' masonry truck fence will be
provided adjacent to the loading area.
4. Requires a F-1 bufferyard and
4. Section 42 Table One establishes a F-1
8 ft. opaque fence along the
buffer yard will be required along the
entire north property line.
northwest corner of the site. For a
distance of 380' along the northern
property line due east from the northwest
corner will not provide a buffer yard. An 8
ft. screening fence is provided along the
remaining north property line.
Building Setbacks
"11" district requires 15 ft. side
Not required along internal boundary lines (as
yard setbacks
shown on plan)
Minimum 10' masonry screen
Truck Loading Area
wall similar to building fagade to
8' masonry fence around truck loading area
Screening
screen view from residential
property
Impervious
Maximum impervious coverages
Allow for the impervious coverage to be
Coverage
shall not exceed 80% of the total
calculated for the entire development as
lot area
opposed to individual lots. (68% shown)
Tree Preservation Ordinance &
25.6% of existing tree canopy will be preserved.
Tree Technical Manual
Coverage is approximately 42.7% and is
Tree Preservation
Ordinance 585-E 7.2.a specifies
predominantly located along the eastern and
that 50% of the existing tree
southern boundary of the site.
canopy shall be preserved.
Variances granted under ZA20-0040:
1. Driveway Ordinance No. 634 requires that driveways maintain a minimum
250' spacing between driveway entrances. Driveway spacing between
driveways will be reduced to a minimum of 193' along Nolen Drive.
Case No.
ZA21-0018
2. Driveway Ordinance No. 634 requires that driveways maintain a minimum
200' spacing between driveways and intersections. Driveway spacing
between intersections will be reduced to a minimum of 145' spacing along
Nolen Drive from Crooked Lane.
3. Driveway Ordinance No. 634 requires a minimum driveway stacking of 100'.
Stacking for the Driveway to Nolan Dr. will be reduced to 59.7'.
At the April 8, 2021 Planning and Zoning Commission meeting, the Commission requested a landscape
rendering showing the tree preservation on Crooked Lane near the residential area. The applicant has
provided the rendering in the packet.
ACTION NEEDED: 1) Conduct a Public Hearing
2) Consider Approval
ATTACHMENTS: (A) Background Information
(B) Vicinity Map
(C) Site Plan Review Summary No. #3, dated April 1, 2021
(D) Surrounding Property Owners Map and Responses
(E) Surrounding Property Owners Responses
Full Size Plans (for Commission and Council members only)
PowerPoint Presentation
Narrative
Approved Zoning Document from ZA20-0040
Plans
Landscape Rendering from Crooked Lane
Traffic Impact Analysis
Corridor Planning Committee Report
SPIN Report
STAFF CONTACT: Ken Baker
Patty Moos
Case No.
ZA21-0018
(817) 748-8067
(817) 748-8269
BACKGROUND INFORMATION
OWNER: GMI
APPLICANT: Claymoore Engineering
PROPERTY SITUATION: 2450 Crooked Lane, Southlake, Texas
LEGAL DESCRIPTION: Tract 11 E, Thomas Easter Survey Abstract No. 474, an addition to the City
of Southlake, Tarrant County, Texas
LAND USE CATEGORY: Mixed Use
CURRENT ZONING: "S -P-2" Generalized Site Plan District
HISTORY: The "AG" Agricultural District zoning was approved with the adoption of
the Zoning Ordinance No 480 and the official Zoning Map on September
19, 1989.
October 20, 2020; City Council approved a Zoning Change and
Site/Concept Plan from "AG" Agricultural District to "S -P-2" Generalized
Site Plan District subject to the Staff Report dated October 13, 2020 and
Site Plan Review Summary No. 4 dated October 8, 2020; granting the
variance requests for granting the variance request for:
1.Driveway Ordinance No. 634 requires that driveways maintain a
minimum 250' spacing between driveway entrances. Driveway
spacing between driveways will be reduced to a minimum of 193'
along Nolen Drive.
2. Driveway Ordinance No. 634 requires that driveways maintain a
minimum 200' spacing between driveways and intersections.
Driveway spacing between intersections will be reduced to a
minimum of 145' spacing along Nolen Drive from Crooked Lane.
3.Driveway Ordinance No. 634 requires a minimum driveway
stacking of 100'. Stacking for the Driveway to Nolan Dr. will be
reduced to 59.7'; and
noting the applicant has removed the four (4) parking spaces (near
Crooked Lane) as requested. (ZA20-0040)
SOUTHLAKE 2035 PLAN: Future Land Use Plan
The site is designated "Mixed Use".
Purpose and Definition: To provide an
option for large-scale, master -planned,
mixed use developments that combine
land uses such as office facilities,
shopping, dining, parks, and residential
uses. The range of activities permitted,
the diverse natural features, and the
varying proximity to thoroughfares of
areas in the Mixed Use category
Case No.
ZA21-0018
Attachment A
Page 1
necessitates comprehensively planned and coordinated development. New
development must be compatible with and not intrusive to existing
development. Further, special attention should be placed on the design
and transition between different uses. Typically, the Mixed Use designation
is intended for medium- to higher -intensity office buildings, hotels,
commercial activities, retail centers, and residential uses. Nuisance -free,
wholly enclosed light manufacturing and assembly uses that have no
outdoor storage are permitted if designed to be compatible with adjacent
uses. Other suitable activities are those permitted in the Public Parks/Open
Space, Public/Semi-Public, Low Density Residential, Medium Density
Residential, Retail Commercial, and Office Commercial categories.
Crooked/Kimball Small Area Plan 2030
The property is also included in the 82 -
acre Crooked/Kimball Small Area Plan.
The Future Land Use designation was
changed from Low Density Residential to
Mixed Use in 2012 as a result of the
recommendations in the plan. The
proposed development area is located
within the 75-LDN overlay for the DFW
airport and prohibits residential uses.
Crooked/Kimball Small Area Plan Adopted Recommendations:
14d.
Low Density
21.5
• Located in the 75 LDN.
• Recommend changing from
Residential/AG and
• Not suitable for residential
Low Density Residential to
SF1-A
uses (prohibited by the
Mixed Use.
airport overlay ordinance).
• Recommend upgrading
• Frontage on Crooked Lane.
Crooked Lane, retaining
• Adjacent to retail
existing two lane facility.
commercial uses.
• If property is developed with
industrial land uses, limit
truck traffic from accessing
Kimball.
Note: The recommendation to
change the underlying land use
designation was not adopted as
part of the 2025 Consolidated Land
Use Plan. The Southlake 2025
underlying land use designation
remained Office Commercial.
2035 Southlake Plan
The Southeast Sector Plan from the 2035 Southlake Plan for the S.
Nolen Drive/Crooked Lane recommendations:
• Provide access or street/cul-de-sac from Village Center to help
Case No. Attachment A
ZA21-0018 Page 2
preserve the rural nature of Crooked Lane.
• Development should occur in a manner that preserves and
integrates the natural tree cover into the area through the use of
open space and creative design.
• Preserve trees adjacent to Crooked Lane to maintain the
character of the roadway.
• Future development on these properties should be approved in
a manner that is sensitive to potential impacts on adjacent
residential areas, particularly as related to noise, traffic, building
heights, lighting and views.
Southeast Sector Playa
Mobility & Master Thoroughfare Plan
The Mobility and Master Thoroughfare Plan shows S. Nolen Drive. to be a
3 -lane undivided arterial with 70 -foot of right of way. The future Village
Center Drive location will be north of the property and connect to S. Nolen
Drive and S. Kimball Avenue; it is planned as a 2 -lane undivided collector
with 60' of right of way. The property will not have direct access to Crooked
Lane, a 2 -lane local street with a 60 -foot right-of-way.
Pathways Master Plan & Sidewalk Plan
There are currently no sidewalks along Crooked Lane or S. Nolen Drive of the
subject property. The Pathways Master Plan indicates a less that 8 -foot wide
sidewalk on both the west side of S. Nolen Drive and the west side of Crooked
Lane. The applicant is providing a 5 -foot sidewalk along the west side of S. Nolen
Drive and a 6 -foot sidewalk on the west side of Crooked Lane.
Case No. Attachment A
ZA21-0018 Page 3
Strategic
Dept.
S. Noler7rookec, La92 Rw2rti Es
Provide access or StrPelj W -de-
Ongoing — Evaluate
CB03;Quality
12, 13, 1.4,
PUS
sac from Village Center to help
development proposals
Development
1.11, 3. 1, 32
Approximately 16 acres.
preserve the rural nature of
perthe
Current land use designation is Mixed Use and Low Density Residential.
Crooked Lane.
recommendations.
Zoning is AG and SF1A_ Surrounding uses include Ww intensity
Development should he of an
residential uses to the south/southwest and office uses to the west,
appropriate scale,height and
north, east, arm] south.
density for the site.
Adjacent to Crooked Lane, a heavily tree -lined 2 -lane local roadway.
If possible, properties should he
master planned or developed in
a coordinated manner.
I !
Development should occur in a
-
manner that preserves and
4'
�
integrates the natural tree cover
into the area thr the use of
open space and creative design.
SE-LJ1
Preserve trees adjacent to
Crooked Lane to maintain the
character of the roadway.
� ■any; 1 ..
'X
•- ` " ' ' L'-
Future development on these
-- -
properties should be approved in
a manner that is sensitive to
-
potential impacts on adjacent
residential areas, particularly as
related to noise, traffic, building
heights, lighting and views.
/
Retain the recommendations of
the Currently adopted
Crooked/Kimball Small Area Plan
as guide for development in this
area.
Mobility & Master Thoroughfare Plan
The Mobility and Master Thoroughfare Plan shows S. Nolen Drive. to be a
3 -lane undivided arterial with 70 -foot of right of way. The future Village
Center Drive location will be north of the property and connect to S. Nolen
Drive and S. Kimball Avenue; it is planned as a 2 -lane undivided collector
with 60' of right of way. The property will not have direct access to Crooked
Lane, a 2 -lane local street with a 60 -foot right-of-way.
Pathways Master Plan & Sidewalk Plan
There are currently no sidewalks along Crooked Lane or S. Nolen Drive of the
subject property. The Pathways Master Plan indicates a less that 8 -foot wide
sidewalk on both the west side of S. Nolen Drive and the west side of Crooked
Lane. The applicant is providing a 5 -foot sidewalk along the west side of S. Nolen
Drive and a 6 -foot sidewalk on the west side of Crooked Lane.
Case No. Attachment A
ZA21-0018 Page 3
TRANSPORTATION
ASSESSMENT:
Area Road Network and Conditions
The site will be accessed by a main driveway entrance at S. Nolen Drive, a
driveway north to the future Village Center Drive and two driveways west
through Pinnacle Point and Kimball Heights commercial developments to
S. Kimball Drive.
Traffic Counts
CrookedS. Nolen Drive (85)
(Between E. Southlake Blvd. and
24hr North Bound 3,036
South Bound 3,068
AM Peak AM 353 11:45 — 12:45AM
Peak AM 345 8:45 — 9:45AM
PM Peak PM 395 4:30— 5:30PM
Peak PM 345 12:45 — 1:45PM
Based on the 2017 City of Southlake Traffic Count Report
Traffic Impact
A Traffic Impact Analysis (TIA) was prepared for this development and is
included with the packet.
* Vehicle Trips Per Day
* AM -In, AM -Out PM -ha and PM -Out are peak hour generators on a weekday
* Based on the ITE: Trip Generation Manual, Th Edition
TREE PRESERVATION: The submitted Tree Conservation Plan complies with the Tree
Conservation Plan approved with Phase 1 of the development. There is
42.7% of existing tree cover and 74.4% of the existing tree cover is
proposed to be removed. The minimum amount existing tree cover
proposed to be preserved is 25.6°/x.
LANDSCAPE: The submitted Landscape Plan complies with the approved Phase I
Concept Plan (ZA20-0040) with the exception of the parking islands that do
not contain the required canopy trees and accent trees, but do not contain
the rest of the other required plant materials. All parking planter islands in
parking areas shall contain a minimum of one (1) canopy tree with the
remaining area in shrubs, ground cover, ornamental grasses or seasonal
color. Planter islands which have light poles for lighting the parking areas
may substitute two (2) understory/accent trees for the required canopy
tree.
UTILITIES: The water line access to the site is located along the west side of S. Nolen
Drive with an 8 -inch water line, a 6 -inch water line on the west side of
Case No. Attachment A
ZA21-0018 Page 4
Crooked Lane, and two (2) 8 -inch water lines at the Pinnacle Point
development to the west of the property.
The property has access to an 8 -inch sewer line along the west side of S.
Nolen Drive and an 8 -inch sewer connection at the Kimball Heights
development to the west.
DRAINAGE: The site drains from the west to the east and southeast towards S. Nolen
Drive and Crooked Lane.
The proposed drainage improvements include a detention pond at the
south end of the property in Phase 1 and an underground drainage pond
(structure) under the parking lot located in the southeast corner of Phase 2.
These structures will drain by underground pipe northeast to an existing
36 -inch drainage pipe located at the southwest corner of the S. Nolen Drive
and Crooked Land intersection. This structure will carry the water under S.
Nolen Drive northeast to an existing drainage channel.
CITIZEN INPUT: The following meetings were held to discuss the development:
A 2035 Corridor Planning Committee meeting was held on June 24, 2020.
The report is provided in the packet.
A SPIN meeting was held on September 22, 2020. The meeting report is
provided in the packet.
PLANNING AND
ZONING COMMISSION: April 8, 2021; Approved (7-0) subject to the Staff Report dated April 1,
2021 and, also subject to the Site Plan Review Summary No. #3, dated
April 1, 2021; and specifically noting approval of the requested variances;
noting the applicant's willingness bring renderings and any additional
information that would help with the views along the Tree Preservation
corridor.
STAFF COMMENTS: Attached is Site Plan Review Summary No. #3, dated April 1, 2021
Case No. Attachment A
ZA21-0018 Page 5
Vicinity Map
2450 Crooked Lane
c "325 + _
2445 2545
244 1 2757
r�
�271'i 2727 M74' 2485 p 220 214 �
2717
425
495
IS
435
r
e�
}
NIP �3
"111
Un
QQ'ryry� n I
71"
A 21-001
Site Plan
' Phase ll
0 90180 360
Fret
Case No. Attachment B
ZA21-0018 Page 1
SITE PLAN REVIEW SUMMARY
Case No.: ZA21-0018 Review No.:Three Date of Review: 4/1/21
Project Name: Site Plan — GMI Phase II
APPLICANT: Claymoore Engineering
Clay Christy
1903 Central Dr.
Bedford, TX 76021
Phone: 817-281-0572
OWNER: Zada M White Estate Trust
Steve Shrum
425 Ridqe Dr.
Grapevine, TX 76051
Phone: 214-637-4300
Email: clay@claymooreeng.com Email: shrum@glaciercommercial.com
CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 3-22-2021 AND WE OFFER THE
FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS
SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE
CONTACT THE APPROPRIATE STAFF MEMBER.
Planning Review
Patty Moos
Planner I
Phone: (817) 748-8269
Email: pmoos(aD-ci.southlake.tx.us
Note: The masonry and articulation requirements in Zoning Ordinance No. 480, as amended,
Section 43, Residential Adjacency Standards, Sections 43.13.a.1 and 43.13.x.4 are not being
met on each elevation. A variance to the to the masonry and articulation requirements would
typically be required but is exempted by HB 2439 of 86th Legislature of the State of Texas. All
materials must meet applicable building codes.
Note: The future addresses for the development will be addressed off S. Nolen Drive.
Tree Conservation/Landscape Review
Keith Martin
Landscape Administrator
Phone: (817) 748-8229
Email: kmartin(a�ci.southlake.tx.us
TREE CONSERVATION COMMENTS:
The submitted Tree Conservation Plan complies with the Tree Conservation Plan approved with
Phase 1 of the development. There is 42.7% of existing tree cover and 74.4% of the existing tree
cover is proposed to be removed. The minimum amount existing tree cover proposed to be
preserved is 25.6%.
Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation
Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in
accordance with the percentage requirements established by Table 2.0. If the property has
previously received a tree permit related to development, the percentage of existing tree cover at
the time the first such permit was issued shall be used to calculate the minimum existing tree
Case No. Attachment C
ZA21-0018 Page 1
cover that must be preserved under this section.
Table 2.0 — Existing Tree Cover Preservation Requirements
Percentage of existing tree cover on
the entire site
Minimum percentage of the
existing tree cover to be
preserved*
70%
-0%-20%
20.1-40%
60%
50%
-40.1%-60%
60.1%-80%
40%
80.1% -100%
30%
*The minimum percentage of existing tree cover to be preserved shall exclude any area in
public rights-of-way as approved by City Council.
For property sought to be zoned for the Downtown zoning district or a planned development
zoning district, including an S -P-1 Site Plan, S -P-2 Site Plan, Transition, Rural Conservation,
Planned Unit Development, or Employment Center zoning district, the City Council shall consider
the application for a Conservation Analysis or Plan in conjunction with the corresponding
development application (as established in Table 1.0). The Planning and Zoning Commission
shall review the application and make a recommendation to the City Council regarding the
application. The City Council shall approve the Plan or Analysis if the Council finds that the Plan
or Analysis provides for the:
placement of building pads, parking areas, driveways, streets, and utility easements so as
to maximize the preservation of environmental features of the property including mature
tree stands, natural creeks and ponds, and significant grades;
maximizes the preservation of tree cover preservation areas indicated on the
Environmental Resource Protection Map;
iii. maximizes the preservation of existing tree stands with the potential to buffer residential
areas from the noise, glare, and visual effects of nonresidential uses;
iv. maximizes the preservation of existing trees, if any, adjoining a natural or man-made
drainage creek;
V. maximizes the preservation of existing protected trees along rural roadways and other
streets as identified and prioritized in the Street Typology designation; and
vi. mitigation of altered trees through proposed tree replacement procedures pursuant to this
Ordinance.
Please be aware that all existing trees shown to be preserved on the City Council approved Tree
Conservation Plan must be preserved and protected during all phases and construction of the
development. Alteration or removal of any of the existing trees shown to be preserved on the
approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning
as approved by the Southlake City Council. Please ensure that the layout of all structures,
easements, utilities, structures grading, and any other structure proposed to be constructed do not
conflict with existing trees intended to be preserved.
LANDSCAPE COMMENTS:
Case No. Attachment C
ZA21-0018 Page 2
The parking islands contain the required canopy trees and accent trees but do not contain the rest
of the other required plant materials. All parking planter islands in parking areas shall contain a
minimum of one (1) canopy tree with the remaining area in shrubs, ground cover, ornamental
grasses or seasonal color. Planter islands which have light poles for lighting the parking areas
may substitute two (2) understory/accent trees for the required canopy tree.
2. Please revise the Interior Landscape Summary Chart to reflect the landscaping for the proposed I-
1 use. It currently shows the required landscaping for a B-2 use.
Indicates informational comment.
# Indicates required items comment.
Development Engineering
Sandra Endy, P.E.
Development Engineer
Phone: 817 -748 -
Email: sendy@ci.southlake.tx.us
GENERAL COMMENTS:
1. This review is preliminary. Additional requirements may be necessary with the review of the civil
construction plans.
SANITARY SEWER
1. Verify that there are no conflicts between the two sanitary sewer manholes along Nolen and the
proposed retaining walls.
DRAINAGE COMMENTS:
1. All detention/retention basins are required to be within a dedicated easement, including
underground storage.
2. Based on the current iSWM tables the infiltration value listed for the 100 -year, 10 -min. storm is
1.627 inches, which calculates to 9.76 in/hr, however, the value used on this plan is 9.24 in/hr.
Please revise to the current values.
3. The total Onsite Proposed Conditions for both Pond A and Pond B listed on Sheet C-5 Preliminary
Detention Calculations doesn't match what is shown on the Proposed Drainage Area Map.
INFORMATIONAL COMMENTS:
Submit 22"x34" civil construction plans and a completed Construction Plan Checklist directly to
the Public Works Administration Department for review. Please allow 15 business days for
review. The plans shall conform to the most recent construction plan checklist, standard
details and general notes which are located on the City's website:
http://www.citVofsouthlake.com/PublicWorks/engineeringdesign.asp
New Requirement: Provide Stormwater Pollution Prevention Plan (SWPPP) per TXR150000.
The plan must include all required elements in Part III, Section F of the permit. The Environmental
Coordinator will review the SWPPP. For instructions on how to complete the review of the
SWPPP please refer to the Stormwater Management for Construction Sites in:
Case No. Attachment C
ZA21-0018 Page 3
https://www.cityofsouthlake.com/2237/Stormwater-Management-for-Construction-S. SWPPP
shall be submitted by second review of the civil construction plans.
A geotechnical report will be required for all private and public roadways. The geotechnical
report shall include pavement design parameters for subgrade stabilization.
A Developer Agreement may be required for this development and may need to be approved
by the City Council prior to any construction of public infrastructure. Construction plans for
these improvements must be acceptable to Public Works prior to placing the Developer's
Agreement on the City Council agenda for consideration.
Any hazardous waste being discharged must be pretreated per Ordinance No. 836.
*=Denotes informational comments that will need to be addressed on the first submittal of the
Civil Construction Plans.
Fire Department Review
Kelly Clements
Fire Marshal
Phone: (817) 748-8223
E-mail: kclements(a.ci.southlake.tx.us
GENERAL COMMENTS:
The required backflow protection (double check valve) for the sprinkler systems can be located on
the riser if the riser is within 100 feet of the water main, measured linearly along the length of the
pipe. If the riser is further than 100 feet from the main, the double check valve shall be in a vault.
Riser rooms shall be a minimum of 5'X5' if the double check is located in a vault, or a minimum of
6'X6' if it is located on the riser. (Label riser room locations to determine termination point of riser
piping, and indicate size of the riser rooms)
The Fire Department Connection for the sprinkler system must be within 100 feet of a fire hydrant,
and within 50 feet of fire department fire lanes on the property. (FDC locations not indicated on the
plans) Add FDC locations, wall mount or remote connection to meet the distance requirements or
add a fire hydrant.
General Informational Comments
* No review of proposed signs is intended with this site plan. A separate building permit is
required prior to construction of any signs.
* All mechanical equipment must be screened of view from right-of-ways and residential
properties in accordance with the Zoning Ordinance No. 480, as amended.
* All lighting must comply with the Lighting Ordinance No. 693, as amended.
* All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment
Control Ordinance No. 946, as amended.
Case No. Attachment C
ZA21-0018 Page 4
It appears that this property lies within the 75 LDN D/FW Regional Airport Overlay Zone and will
require construction standards that meet requirements of the Airport Compatible Land Use Zoning
Ordinance No. 479.
Development must comply with all requirements in Zoning Ordinance No. 480, Section 43,
Overlay Zones.
The applicant should be aware that prior to issuance of a building permit a Plat must be processed
and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan,
and building plans, must be submitted for approval and all required fees must be paid. This may
include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer
Impact and Tap Fees, and related Permit Fees.
Denotes Informational Comment
Case No. Attachment C
ZA21-0018 Page 5
SURROUNDING PROPERTY OWNERS MAP
s
2
24M 2535
ta5� nz5 �Sa���k�BCVp „
2495 ��
D R 240 2757
24852313 2321 2787 z
zw z� 219
0
2777
m
� fr
Y
N
T
B 'A
b
h
21W
P P
2737
C, 1�
� g
7t0 a n
EXCHA
^� l29 H N 2815 2819 2825 283.
903
Q F
SPO #
Owner
Zoning
Physical Address
Acreage
Response
1.
TRI DAL REAL ESTATE LTD
SF1-A
505 S KIMBALL AVE
4.03
NR
2.
STRUEMPLER, BOBBY G
SF1-A
700 WHISPERING WOOD
2.27
O
3.
LIMC REAL ESTATE LLC
SP1
410 S NOLEN DR
0.60
NR
4.
CAVU EQUITY GROUP LLC
SP1
416 S NOLEN DR
0.60
NR
5.
VARIA, AMEE
SF1-A
2449 CROOKED LN
1.60
NR
6.
MYAN PLAZA LP
01
520 SILICON DR
1.43
NR
7.
SILICON TEXAS PROPERTIES LLC
SPI
512 SILICON DR
0.65
NR
8.
CCW -516 SILICON LLC
SP1
516 SILICON DR
0.73
NR
9.
FATCAT LLC
SPI
508 SILICON DR
0.66
NR
10.
TRI DAL REAL ESTATE LTD
SF1-A
2450 CROOKED LN
3.20
NR
11.
ZADA M WHITE ESTATE TRUST
AG
2450 CROOKED LN
12.94
NR
12.
TOULA KIMBALL -SOUTH LAKE INVEST
SP2
415 S KIMBALL AVE
1.64
NR
13.
2021 PRIMROSE OFFICE II LLC
AG
200 S NOLEN DR
1.54
NR
14.
NOLEN PROPERTY LLC
SP2
405 S NOLEN DR
2.26
NR
15.
CURRENT OWNER
SP1
305 S NOLEN DR
1.83
NR
16.
MPA SOUTHLAKE MOB LLC
SP1
300 S NOLEN DR
1.83
NR
17.
BTR -8 SOUTHLAKE LLC
SP2
2707 E SOUTHLAKE BLVD
5.76
NR
18.
CESANDER, LAURENCE P
01
2485 E SOUTHLAKE BLVD
1.34
NR
19.
495 KIMBALL LLC
SP1
495 S KIMBALL AVE
0.73
NR
20.
CHURCH OF CHRIST OUR KING
SP1
595 S KIMBALL AVE
3.96
NR
21.
495 KIMBALL LLC
SP1
495 S KIMBALL AVE
0.53
NR
22.
SP SOUTHLAKE-KIMBALL II LLC
SP2
455 S KIMBALL AVE
7.30
NR
23.
495 KIMBALL LLC
SP1
495 S KIMBALL AVE
0.54
NR
Case No. Attachment D
ZA21-0018 Page 1
24.
Superintendent of Carroll ISD
NR
25
Superintendent of Grapevine Colleyville
ISD
NR
26.
Superintendent of Northwest ISD
27.
Superintendent of Keller ISD
Responses: F: In Favor O: Opposed U: Undecided NR: No Response
Notices Sent: Twenty-five (25)
Responses Received within 200': In Favor: 0 Opposed: 1 Undecided: 0 No Response: 24
Case No. Attachment D
ZA21-0018 Page 2
SURROUNDING PROPERTY OWNERS RESPONSES
Notification Response Form
ZA21-0018
Meeting Date: April 8, 2021 at 6:30 PM
STRIJErt PLER, BOBBY G
700 WHISPERING WOOD CIR
OUTHLAKE, TX 76092
Direct questions and mail responses to.
City of Southlake
Planning 8 Development Services
Notification Response
1400 Main St, Ste 30
SDuthlake, TX 76092
Phone: (817) 748-8621
Fax: (817) 748-6477
PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY
BEFORE THE START OF THE SCHEDULED PUBLIC HEARING.
Being the owner(s) of the property so noted above, are hereby
in favor ofopt wd Io undecided about
(circle nr underline one)
the proposed Site Plan referenced above.
Space for comments regarding your position:
A iK:WC AA rl,+l1 P- ) Al 136 11-1 P AZA o t1 l, F- r' ac -S
r"ccl is IV tt c •+t'
Signature; Date: c}zi
Additional Signature: Gate:
Printed Name(s): orRgF- LE -,Q -
Must be property ownerCsl vAv-.e narne(s) are printed al top. bthem dse contacl the Planning Department. One farm per piopery.
Phone Number (optional): 2?l 7 — / S, f 1
5 2 -
Case No. Attachment E
ZA21-0018 Page 1