Loading...
Item 6C - PlansSCOPE OF WORK TO INSTALL A SOLAR PHOTOVOLTAIC (PV) SYSTEM AT THE GATES RESIDENCE, LOCATED AT 1211 TIMBER COURT, SOUTHLAKE, TEXAS. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. SYSTEM RATING 18.6 kW DC STC 18.0 kW AC EQUIPMENT SUMMARY (57) SUNPOWER SPR -E20 -327 -E -AC PV MODULES (57) SUNPOWER SPR -E20 -327 -E -AC [240VI PV INVERTERS (452) (42 X 10.75') LINEAR FEET SUNPOWER INVISIMOUNT SHEET INDEX PV -0 COVER PV -1 SITE MAP AND PV LAYOUT PV -2 STRING MAP AND MONITORING LAYOUT PV -3 ELECTRICAL DIAGRAM PV -4 EQ WALL & MOUNTING DETAIL PV -5 SYSTEM LABELING DETAIL PV -6 SAFETY PLAN GOVERNING CODES 2020 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL FIRE CODE UNDERWRITERS LABORATORIES (UL) STANDARDS OSHA 29 CFR 1910.269 7NACIFIED PV Installation Professional Mark McManus Cert #PV -0421 18-020534 114 ' I Gayll &C . Southiake wh Keller Walmart Supercenter 9 1211 Timber Ct. Southlake, TX,., ?, Lowe's Home improvement Pnllawll'lo Target Q 17Mf-% ICl-%T 1 rll%A'r1f-%KI 1 1 \VaJLV 1 LV VlI 1 IVI V VICINITY MAP Timber Ct (1211 -- imber .thlake, TX... DESIGN BY: FREEDOM SOLAR, LLC REVISIONS DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B O F --- w O CONTRACTOR FREEDOM" SOLAr mOWER FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME N 0) O w O rn o U Nt }� X I ~WU) H N in LU LU ^ Q ~ Q r J N r N 1-- 0 O U) SHEET NAME COVER SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -0 LEAD ID: 38723 CONSTRUCTION SUMMARY (57) (57) (SUNPOWER SPR -E20 -327 -E -AC) SOLAR MODULES, 18.6 kW DC MODULE DIMENSIONS = 41.2" X 61.3" X 1.80" SUNPOWER SPR -E20 -327 -E -AC [240V] PV INVERTERS COMBINED INVERTER OUTPUT = 18.0 kW AC. (39 X 10.75') LINEAR FEET SUNPOWER INVISIMOUNT SPCR-CH ROOF ATTACHMENTS SUNPOWER MONITORING SITE DETAILS ROOF TYPE: ASPHALT SHINGLE ARRAY #1 - TILT = 24°, AZIMUTH = 178° ARRAY #2 - TILT = 24°, AZIMUTH = 178° ARRAY #3 - TILT = 24°, AZIMUTH = 178° DETAIL SUNPOWER INVISIMOUNT RAIL (TYP. SPCR-CH ROOF ATTACHMENT (TYP. SUNPOWER PV MODULE (TYP. RAFTER (TYP.) ON 24" CENTERS SOLAR LOAD CENT PV AC DISCONNECT -VISIBLE BREAK -LOCKABLE -LABELED -LOCATED WITHIN 50' OF ONCOR REVENUE METER GROUNDING ELECTRODE MAIN DISTRIBUTION PANEL#2 -INSIDE GARAGE (E) EXISTING DETACHED STRUCTURE PV Installation Professional Mark McManus ..A Cert #PV -042118-020534 CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.) TYP. ROOF ATTACHMENT SPACING SHALL BE 6-0" MAX FOR LAG BOLT TYPE ROOF ATTACHMENTS ANCHORED TO RAFTERS 5.) TYP. ROOF ATTACHMENT SPACING SHALL BE 4'-6" MAX FOR S-5! CLAMPS ANCHORED TO STANDING SEAM ROOF PANELS PV ARRAY #1 (32) MODULES GROUNDING ELECTRODE MAIN DISTRIBUTION PANEL#1 -INSIDE HOUSE \-ONCOR REVENUE METER #147 630 683 ESID #10443720002664515 NEW FEED -THROUGH PANEL SOLAR LOAD CENTER MONITORING PV AC DISCONNECT - VISIBLE BREAK -LOCKABLE -LABELED - LOCATED WITHIN 10' OF ONCOR REVENUE METER PV ARRAY #3 (18) MODULES PV ARRAY #2 (7) MODULES FIRE CODE SETBACK PER IFC 1204.2.1 UTILITY CONTROLLED OUTAGE REQUIRED TO INSTALL NEW EXTERIOR EATON CH8B200RF FEED -THROUGH PANEL WITH CSR220ON MBK. -MOVING FEEDER BREAKERS TO GARAGE (100A) & GUEST HOUSE (125A) SUB PANELS TO THE NEW FEEDTHROUGH PANEL. -(2) SEPARATE EQ WALLS. DESIGN BY: L EEDOMFIR SOLAR, LLC REVISIONS DESCRIPTION DATE REV DESIGN PACKET 01/30/2021A DESIGN PACKET 03/16/2021 B CONTRACTOR FREEDOM" SOLAR POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET NAME - SITE MAP & PV LAYOUT SHEET SIZE ANSI B 11" x 17" ROUNDING ELECTRODE SHEET NUMBER MAIN DISTRIBUTION PANEL#3 PV -1 N CY) 0 w � ~ O U W U) X H Lo C:)J "t, N W Q ED LLJ Q .-. U _ N � O SHEET NAME - SITE MAP & PV LAYOUT SHEET SIZE ANSI B 11" x 17" ROUNDING ELECTRODE SHEET NUMBER MAIN DISTRIBUTION PANEL#3 PV -1 DESIGN BY: FREEDOM SOLAR, LLC REVISIONS DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2031 B CONTRACTOR FREEDOM" A POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME N O F f W O X 0 ~ W H N W00 1 2 w -1 Q F- Q ( J N 2 N H D 0 SHEET NAME STRING MAP MONITORING LAYOUT Ails SHEET SIZE ANSI B 11" x 17" PV Installation Professional SHEET NUMBER Mark McManus SUNPOWER SUPERVISOR S/N PV -2 Cert#PV-042118-020534 SUNPOWER SUPERVISOR S/N DESIGN BY: FREEDOM SOLAR, LLC REVISIONS DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B O ry ~ f W O CONTRACTOR FREEDOM" A POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME N O ry ~ f W O X 0 ~ W F- N U) W00 2 1 w -1 Q F- Q ( J N 2 N F- D D O U) SHEET NAME STRING MAP MONITORING LAYOUT SHEET SIZE ANSI B Alk 11"x 17" SHEET NUMBER PV -2A PV Installation Professional Mark McManus Cert#PV-042118-020534 SOLAR ARRAY - 12.8kW DC STC (39) (SUNPOWER SPR -E20 -327 -E -AC) MODULES JUNCTION BOX: TRANSITION FROM DG CABLE TO AWG #10 THWN-2 NEMA 3R, UL LISTED \ BRANCH #1 \ 8 11 MODULES BRANCH #2 8 11 MODULES �_L BRANCH #3 8 10 MODULES ti BRANCH #4 8 7 MODULES (39) (SUNPOWER SPR E20 -327 -E -AC [240] ) INVERTERS 240VAC, 1.31 A MAX CEC WEIGHTED EFFICIENCY 97.5% NEMA 4R, UL LISTED, INTERNAL GFDI UTILITY CONTROLLED OUTAGE REQUIRED TO INSTALL NEW EXTERIOR EATON CH813200RF FEED -THROUGH PANEL WITH CSR220ON MBK. SOLAR LOAD CENTER #1 240 VAC, 125A NEMA 3R, UL LISTED (5) 2P -20A BREAKERS 20A 20A I - 2 0A 20A 20A F_ (3) AWG 2/0 CU THWN-2 IN 2" CONDUIT PV AC DISCONNECT #1 240VAC, 100A FUSIBLE, WITH (2) 70A FUSES NEMA 3R, UL LISTED VISIBLE, LOCKABLE, LABELED WITHIN 10' OF THE ONCOR TO REVENUE METER GUEST 70A HOUSE - v SUNPOWER (3) AWG #6 THWN-2 MONITORING (1) AWG #8 THWN-2 GND IN 1" CONDUIT (8) AWG #10 THWN-2 (1) AWG #8 THWN-2 GND IN 3/4" CONDUIT SOLAR ARRAY - 5.89kW DC STC (18) (SUNPOWER SPR -E20 -327 -E -AC) MODULES JUNCTION BOX: TRANSITION FROM DG CABLE SOLAR LOAD CENTER #2 TO AWG #10 THWN-2 240 VAC, 125A NEMA 3R, UL LISTED NEMA 3R, UL LISTED \ (2) 2P -20A BREAKERS BRANCH #1 8 9 MODULES ti BRANCH #2 9 MODULES (14) (SUNPOWER SPR E20 -327 -E -AC [240]) INVERTERS 240VAC, 1.31 A MAX CEC WEIGHTED EFFICIENCY 97.5% NEMA 4R, UL LISTED, INTERNAL GFDI (4) AWG #10 THWN-2 (1) AWG #8 THWN-2 GND IN 3/4" CONDUIT 20A 20A PV AC DISCONNECT #2 240VAC, 60A FUSIBLE, WITH (2) 40A FUSES NEMA 3R, UL LISTED VISIBLE, LOCKABLE, LABELED WITHIN 50' OF THE ONCOR REVENUE METER 40A F_ I I (4) AWG #6 THWN-2 (1) AWG #8 THWN-2 GND IN 1" CONDUIT -MOVING FEEDER BREAKERS TO GARAGE (100A) & GUEST HOUSE (125A) SUB PANELS TO THE NEW FEEDTHROUGH PANEL. -(2) SEPARATE EQ WALLS. ONCOR REVENUE METER O #147 630 683 ESID #10443720002664515 1 -PHASE, 240V 200A 125A 100A 100A POINT OF INTERCONNECTION PER NEC 240.21(6)(1) -OR- 705.31 LENGTH OF TAP CONDUCTORS SHALL NOT EXCEED 10 FT FROM POINT OF INTERCONNECT TO OCPD MAIN SERVICE DISCONNECT 240V, 200A FEED -THROUGH PANEL EATON CH8B200RF ('"GRADE) 1 P3W, 240V, 225A BUS 100A FEEDER BREAKER (3) AWG 2/0 CU THWN-2 (1) AWG #6 THWN-2 GND IN 2" CONDUIT EXISTING MAIN DISTRIBUTION PANEL GE,1 P3W 240V, 200A BUS -INSIDE HOUSE JI EXISTING WIRES EXISTING GROUNDING ELECTRODE SYSTEM EXISTING GARAGE PANEL GE, 1 P3W, 240V, 125A BUS POINT OF INTERCONNECTION PER NEC 240.21(B)(1) -OR- 705.31 LENGTH OF TAP CONDUCTORS DESIGN BY: FREEDOM SOLAR, LLC DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B CONTRACTOR FREEDOM" SOLAR POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME w J U) W H Q C� N 0) 0 H � r ~ O Q CD X[If LU I W H N W Q = N N O U) SHALL NOT EXCEED 10 FT FROM SHttl NAMt �POINT OF INTERCONNECT TO OCPD ELECTRICAL EXISTING GROUNDING DIAGRAM ELECTRODE SYSTEM 1 � � SHEET SIZE ANSI B 11" x 17" PV Installation Professional SHEET NUMBER Mark McManus PV -3 Cert #PV -04211 8-020534 MAIN HOUSE ELECTRICAL CALCULATION: - CALCULATIONS FOR CURRENT CARRYING CONDUCTORS CALCULATIONS FOR OVERCURRENT DEVICES INVERTER OUTPUT WIRE AMPACITY CALCULATION INVERTER BRANCH AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) MAXIMUM INVERTER BRANCH CURRENT = (12)(1.31A) = 15.7A MAXIMUM BRANCH INVERTER CURRENT = (12)(1.31A) = 15.7A CONTINUOUS USE: MINIMUM OCPD = (15.7A)(1.25) = 19.6A #10 WIRE 75°C DERATED AMPACITY = (0.80)(35.OA) = 28.OA USE 2P -20A BREAKERS IN SOLAR LOAD CENTER FOR INVERTER BRANCH OCPD 28.OA> 15.7A CONDITIONS OF USE: SYSTEM AC CURRENT CALCULATION #10 WIRE 90°C DERATED AMPACITY = (0.91)(0.7)(40.OA) = 25.5 [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) 25.5 15.7A COMBINED CURRENT = (39)(1.31A) = 51.1A W J ~ MINIMUM OCPD = (51.1A)(1.25) = 63.9A SOLAR LOAD CENTER OUTPUT WIRE AMPACITY CALCULATION USE (2) 70A FUSES IN PV AC DISCONNECT FOR SYSTEM OCPD [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) NOTE: AWG #6 CONDUCTORS ARE ADEQUATELY PROTECTED BY 70A FUSES COMBINED CURRENT = (39)(1.31A) = 51.1A r CONTINUOUS USE: #6 WIRE 75°C DERATED AMPACITY = (0.80)(65A) = 51.1A N 52.OA > 51.1A CONDITIONS OF USE: #6 WIRE 90°C DERATED AMPACITY = (0.91)(75A) = 68.3A N 68.3A > 51.1 A GARAGE ELECTRICAL CALCULATION: - CALCULATIONS FOR CURRENT CARRYING CONDUCTORS CALCULATIONS FOR OVERCURRENT DEVICES INVERTER OUTPUT WIRE AMPACITY CALCULATION INVERTER BRANCH AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) MAXIMUM INVERTER BRANCH CURRENT = (12)(1.31A) = 15.7A MAXIMUM BRANCH INVERTER CURRENT = (12)(1.31A) = 15.7A CONTINUOUS USE: MINIMUM OCPD = (15.7A)(1.25) = 19.6A #10 WIRE 75°C DERATED AMPACITY = (0.80)(35.OA) = 28.OA USE 2P -20A BREAKERS IN SOLAR LOAD CENTER FOR INVERTER BRANCH OCPD 28.OA > 15.7A CONDITIONS OF USE: SYSTEM AC CURRENT CALCULATION #10 WIRE 90°C DERATED AMPACITY = (0.91)(0.80)(40.0A) = 29.1A [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) 29.1A > 15.7A COMBINED CURRENT = (18)(1.45A) = 23.6A W J ~ MINIMUM OCPD = (23.6A)(1.25) = 29.5A SOLAR LOAD CENTER OUTPUT WIRE AMPACITY CALCULATION USE (2) 40A FUSES IN PV AC DISCONNECT FOR SYSTEM OCPD [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR -E20 -327 -E -AC [240V]) NOTE: AWG #6 CONDUCTORS ARE ADEQUATELY PROTECTED BY 40A FUSES COMBINED CURRENT = (18)(1.31A) = 23.6A r CONTINUOUS USE: #6 WIRE 75°C DERATED AMPACITY = (0.80)(65A) = 52.OA N 52.0 > 23.6A CONDITIONS OF USE: #6 WIRE 90°C DERATED AMPACITY = (0.91)(75A) = 68.3A N 68.3A > 23.6A ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90-C WET ENVIRONMENT UNLESS OTHERWISE NOTED. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MAXIMUM MOUNTING HEIGHT FROM GRADE TO CENTER OF METER SOCKET SHALL BE 72" FOR RESIDENTIAL SINGLE PHASE METER SOCKETS 0-320 AMPS. MINIMUM MOUNTING HEIGHT IS 30" FROM FOR AUSTIN ENERGY, AND 48" FOR ALL OTHER JURISDICTIONS 9.) MINIMUM HORIZONTAL CLEARANCE FROM GAS REGULATOR TO ANY ELECTRICAL ENCLOSURE IS 36", EXCEPT AUSTIN ENERGY WHICH REQUIRES 48" CLEARANCE FROM GAS TO METER SOCKET 10.) PV DISCONNECT SHALL BE VISIBLE, LOCKABLE AND LABELED AND THE DOOR CANNOT BE OPENED WHEN HANDLE IS IN ON POSITION 11.) BY DEFAULT THE MONITORING DEVICE IS SHOWN CONNECTED TO A 20 -AMP BREAKER IN THE SOLAR LOAD CENTER. ALTERNATIVELY, THE MONITORING DEVICE MAY BE CONNECTED TO A 20 -AMP BREAKER AT THE MAIN DISTRIBUTION PANEL. PV Installation Professional Mark McManus Cert #PV -0421 1 8-020534 DESIGN BY: FREEDOM SOLAR, LLC REVISIONS DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B CD r W J ~ O U W <w H L(� L6 N W Q ~ LU Q r CONTRACTOR FREEDOM" SOLAR POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET NAME ELECTRICAL DIAGRAM SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -3A N m CD r W J ~ O U W <w H L(� L6 N W Q ~ LU Q r U, r N N 1-- D 0 U) SHEET NAME ELECTRICAL DIAGRAM SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -3A SEE( V E NEW FEED -THROUGH PANEL - OUTSIDE HOUSE WALL - POINT OF INTERCONNECTION MAIN DISTRIBUTION PANEL#1 - INSIDE MAIN HOUSE WALL MAIN DISTRIBUTION PANEL#2 - INSIDE GARAGE WALL PV AC DISCONNECT #2 SOLAR LOAD CENTER #2 13:Z�11 ' �;ftG MOUNTING METHOD NTS I I I I I I I F I I I I I I I I I I 0 I I I I I I I L-- —� ONCOR REVENUE METER PV MODULE ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT SUNPOWER FLASHING, 12"x12"x0.050", 5050, MILL PV AC DISCONNECT #1 SOLAR LOAD CENTER #1 FROM PV ARRAY MONITORING PV Installation Professional Mark McManus Cert#PV-042118-020534 EQUIPMENT ELEVATION NTS GROUNDING END/MID CLAMP SUNPOWER INVISIMOUNT RAIL COMPOSITE SHINGLE ROOF 5/16"x3" SS LAG BOLT WITH MIN 2%2' THREAD EMBEDMENT, SEALED PENETRATION INTO RAFTERS 2X6 RAFTERS @ 24" OC MOUNTING DETAIL J NTS DESIGN BY: FREEDOM SOLAR, LLC DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B CONTRACTOR m FREEDOM FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME LL] J H U) W I -- Q O Of W m r r N N d') O co r` V) Q W H W Y Q J I- D 0 U) SHEET NAME EQ.WALL & MOUNTING DETAIL SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -4 NOTE: NOT ALL LABELS MAY BE APPLICABLE REQ'D BY: NEC 690.1 APPLY TO: PV DISCONNECT REQ' BY: AHJ APPLY TO: REVENUE METER SOCKET (IF APPLICABLE) A E REQ'D BY: 690.56(1)(a) n APPLY TO: PV DISCONNECT REQ'D BY: NEC 690.13(B APPLY TO: PV DISCONNECT REQ'D BY: AHJ APPLY TO: REVENUE METER SOCKET (IF APPLICABLE) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE' OFF" POSITION OSHUT DOWN /4\� PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LL- B . REQ'D BY: NEC 690.31(G)(3 REQ'D BY: FREEDOM SOLAR �� I APPLY TO: MAIN DISTRIBUTION PANEL APPLY TO: RACEWAYS, CABLE TRAYS, OTHER WIRING METHODS, AND ENCLOSURES THAN CONTAIN PV SYSTEM DC CONDUCTORS C REQ'D BY: NEC 705.12(13)(2)(3)(O APPLY TO: DISTRIBUTION EQUIPMENT ADJACENT TO BACK -FED BREAKER F REQ'D BY: FREEDOM SOLAR A G APPLY TO: - MONITORING DEVICE ENCLOSURE SIGNAGE REQUIREMENTS > RED BACKGROUND > WHITE LETTERING > MIN. 3/8" LETTER HEIGHT > ALL CAPITAL LETTERS > ARIAL OR SIMILAR FONT > REFLECTIVE, WEATHER RESISTANT MATERIAL, UL 969 PV Installation Professional Mark McManus Cert#PV-042118-020534 DESIGN BY: FREEDOM SOLAR, LLC DESCRIPTIONDATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B CONTRACTOR FREEDOM" SOL1 FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 I'RUJHCI NAME SHEET NAME SYSTEM LABELING DETAIL SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -5 N O') O r p ~ r W J � ~ O U W 0 x I— LO c) "T I N W U W _ N � O CO SHEET NAME SYSTEM LABELING DETAIL SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -5 DRAW IN CONTROLLED ACCESS ZONE (CAZ) BOUNDARY AND LADDER PLACEMENT ON SITE PLAN BELOW. HARD HAT IS REQUIRED AT ALL TIMES IN CAZ Q w 0 COMPETENT PERSON: TIMBER COURT JOB START DATE: PV Installation Professional Mark McManus Cert #PV -042118-020534 CONDUCT SAFETY MEETING WITH ALL CREW MEMBERS ON SITE AT THE BEGINNING OF EACH JOB. USE SIGN IN SHEET BELOW. 1� 2. 3. 4. 5. GUEST SIGN IN 1. 2. 3. DESIGN BY: [FREEDOM SOLAR, LLC DESCRIPTIONDATE f�RAEV DESIGN PACKET 01/30/2021 DESIGN PACKET 03/16/2021 1 B CONTRACTOR FREEDOM" SOLAR POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET NAME SAFETY PLAN SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -6 N O') (D w J ~ O U W U) H o N W Q UJ Q , U _ N I --- D O U) SHEET NAME SAFETY PLAN SHEET SIZE ANSI B 11" x 17" SHEET NUMBER PV -6 Fundamentally Different. And Better. The SunPower®Maxeon®Solar Cell • Enables highest -efficiency modules available. z • Unmatched reliability • Patented solid metal foundation prevents breakage and corrosion 1 Factory -integrated Microinverter • Simpler, faster installation • Integrated wire management, rapid shutdown • Engineered and calibrated by SunPower for SunPower modules SUNPOWER0 SunPower° E -Series: E20-327 I E19-320 SunPoweroResidentia AC Module Built specifically for use with the SunPower Equino)CI system, the only fully integrated solution designed, engineered, and warranted byone manufacturer. " Maximum Power. Minimalist Design. AF,FAI Industry-leading efficiency means more power and savings iii per available space. With fewer modules required and hidden microinverters, less is truly more. rA Highest Lifetime Energy and Savings. Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.' 150% 3 140% Q 130% 9 120% tU T 110°k 100% C 90% CID 90% 70% N 60% 0 I I2u 25 Years of operation Up to 60% more lifetime energy Best Reliability. Best Warranty. With more than 25 million modules deployed around the world, SunPower technology is proven to last. That's why we stand behind our module and microinverter with the industrys best 25 -year Combined Power and is Product Warranty, including the highest Power Warranty in solar. 3 90 100 Data Inverter Model: Enphase IQ 7XS (IQ7XS-96-ACM-US) 0 98% Peak Output Power 320 VA 320 VA 2 96% 315 VA 315 VA Nom. (L -L) Voltage/Rangel (V) d Max. Continuous Output Current (A) 1.31 1.51 � 9496 12 (single phase) 10 (two pole) wye 92% 97.5% 97.0% Nom. Frequency E 9096 Extended Frequency Range 12% 8a% more C 6646 - power i 84% azoELin year 3 so% 0 (': 15 20 25 Years of operation E -Series: E20-327 I E19-320 SunPower°Residential AC Module AC Electrical Data Inverter Model: Enphase IQ 7XS (IQ7XS-96-ACM-US) @240 VAC @208 VAC Peak Output Power 320 VA 320 VA Max. Continuous Output Power 315 VA 315 VA Nom. (L -L) Voltage/Rangel (V) 240 / 211-264 208 / 183-229 Max. Continuous Output Current (A) 1.31 1.51 Max. Units per 20 A (LL) Branch Circuit' 12 (single phase) 10 (two pole) wye CEC Weighted Efficiency 97.5% 97.0% Nom. Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 5.8 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor (adjustable) 0.7 lead./ 0.7 lag. No active phase balancing for three-phase installations DC Power Data Warranties, Certifications, and Compliance SPR -E20 -327 -E -AC SPR -E19 -320 -E -AC Warranties 25 -year limited power warranty Nom. Power I(Pnom) 327 W 320 W 25 -year limited product warranty Power Tol. +5/-0% +5/-0% UL 1703 • UL 1741 /IEEE -1547 Certifications Module Efficiency 20.4% 9.9% UL 1741 AC Module (Type 2 fire rated) Temp. Coef. (Power) -0.35%/'C -0.35%/'CUL 62109-1 / IEC 62109-2 Compliance . FCC Part 15 Class B -Three bypass diodes ICES -0003 Class B Shade Tol. • Integrated module -level maximum CAN/CSA-C22.2 NO. 107.1-01 power point tracking CA Rule 21 (UL 1741 SA)" (includes Volt/Var and Reactive Power Priority) Tested Operating Conditions UL Listed PV Rapid Shutdown Equipment6 Operating Temp. -40'F to +185'F (-40'C to +85°C) Enables installation in accordance with; • NEC 690.6 (AC module) Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back NEC 690.12 Rapid Shutdown (inside and outside the array) Snow: 125 psf, 6000 Pa, 611 kg/m2 front NEC 690.15 AC Connectors, 690.33(A) -(E)(1) Impact Resistance 1 Inch (25 mm) diameter hail at 52 mph (23 m/s) When used with InvisiMount racking and InvisiMount accessories Mechanical Data (UL 2703): Solar Cells 96 Monocrystalline Maxeon Gen III Module grounding and bonding through Invisilvount Class Afire rated Front Glass High -transmission tempered glass with When used with AC module Q Cables and accessories (UL 6703 and anti -reflective coating UL 2238)6: Environmental Rating Outdoor rated • Rated for load break disconnect FrameClass 1 black anodized (highestAAMA rating) PID Test Potential -induced degradation free Weight 42.9 1 bs (19.5 kg) p+ tsssmm�t�m.l Recommended Max. 1.3 in. (33 mm) Module Spacing T 1 1 SunPower 360 W compared to a conventional module on same -sized arrays (260 W, 16% 46 mm efficient, approx. 1.6 m2),4% more energy per watt (based on third -party module 0A In.) characterization and PVSini 0.75%/yr slower degradation (Cam pea u, Z. et al. "Sun Power Module Degradation Rate," SunPower white paper, 2013). 1 2 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of 2017. t. mm -`-30mm Jan uary 3#1 rank in"Fraunhofer PV Durability lnitiativefor5olarModules: Part 3."PVTechPower t4t2 In.) 17'zin"lam Magazine, 2015. Campeau, Z. etal. "Sun Power Module Degradation Rate,"Su in Powerwhite paper, 2013. 4 Factorysetto 1547a-2014 defaultsettings. CA Rule 21defaultsettingsprofile setduring 393 mm commissioning. See the Equinox Installation Guide #518101 for more information. 1ts.s )n:l !Standard Test Conditions (1000 W/M2 irradiance, AM.1.5,25'C). NREL calibration,,,_ f f module. 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer's instructions. See www.sunpower.com/facts for more reference information. For more details, see extended datasheet www.sunpower.com/datasheets Specifications included in this datasheet aresubjectto change without notice. 02018 SunPower Corporation. All Rights Reserved. SUN POWER, the SUNPOWER logo and MAXEON are registered trademarks of SunPower corporation in the U.S. and other countries as well. 1-800-SUNPOWER. f 433 mm y ft72-1 r,c Woasc 3� �FkAOBy.i rR S U P V11 E R Molumon4y� ds FM• NrlType 7 Please read the Safety and Installation Instructions for details. 531 948 RevA Improve Support, Reduce Maintenance Costs An intuitive monitoring website enables you to: See a visual map of customer sites Remotely manage hundreds of sites Receive elective system reports Locate system issues and remotely diagnose Diagnose issues online Drill down for the status of individual devices reuinm Add Value for Customers With the SunPower Monitoring System customers can: See what their solar system produces each day, month, or year Optimize their solar investment and save on energy expenses See their energy use and estimated bill savings See their solar system's performance using the SunPower monitoring website or mobile app SunPower EnergyLink—Plug-and-Play Installation This complete solution for residential and commercial monitoring and control includes the SunPower' PV Supervisor 6 (PVS6) which improves the installation process, overall system reliability, and customer experience. Compact footprint for improved aesthetics Robust cloud connectivity and comprehensive local connectivity Flexible configuration of devices during installation Consumption metering Revenue -grade production metering (pending) Web -based commissioning Remote diagnostics of PVS6 and inverters Durable UL Type 3R enclosure reduces maintenance costs Easy integration with SunPower eBOS G Robust Cloud Connectivity Multiple options to maintain optimal connectivity: • Hardwired Ethernet Wi-Fi Cellular backup SunPower Monitoring Websites IIJ 11II � ��- �u��,�irill�aii4l�lllii iaYW�Yi PVS6 Multiple communication options include Ethernet, Wi-Fi, and cellular. Site .e qLjirements Number of SunPovver AC modules monitor.us,sunpower.com Add Value for Customers With the SunPower Monitoring System customers can: See what their solar system produces each day, month, or year Optimize their solar investment and save on energy expenses See their energy use and estimated bill savings See their solar system's performance using the SunPower monitoring website or mobile app SunPower EnergyLink—Plug-and-Play Installation This complete solution for residential and commercial monitoring and control includes the SunPower' PV Supervisor 6 (PVS6) which improves the installation process, overall system reliability, and customer experience. Compact footprint for improved aesthetics Robust cloud connectivity and comprehensive local connectivity Flexible configuration of devices during installation Consumption metering Revenue -grade production metering (pending) Web -based commissioning Remote diagnostics of PVS6 and inverters Durable UL Type 3R enclosure reduces maintenance costs Easy integration with SunPower eBOS G Robust Cloud Connectivity Multiple options to maintain optimal connectivity: • Hardwired Ethernet Wi-Fi Cellular backup SunPower Monitoring Websites IIJ 11II � ��- �u��,�irill�aii4l�lllii iaYW�Yi PVS6 Multiple communication options include Ethernet, Wi-Fi, and cellular. Site .e qLjirements Number of SunPovver AC modules monitor.us,sunpower.com supported per PVS6 85 Browsers High-speed internet access via accessible Internet access router or switch Customer app • 100-24C VAC (L -N), 50 or 60 Hz Power 2. on a mobile device, download the SunPower Monitoring Zli • 208 VAC (L -L in 3-phase), 60 Hz Mechanical Weight 5.5 Ibs (2.5 kg) Dimensions 11.8 x 8.0 x 4.2 in. (30.5 x 20.5 x 10.8 cm) Enclosure rating UL50E Type 3R SunPower AC Modules Operating Temperature -221F to +140'F (-30'C to +60°G) Humidity(maximum) 95%, non -condensing Web and Mobile Device Support Customer site monitor.us,sunpower.com Partner site pvsmgmt.ussunpower.com Browsers Hrefox, Safari, and Chrome Mobile devices iPhonel, iPacll, and Android TI Customer app 1. Create account online at: monitor. us.sunpower.com. Cellular 2. on a mobile device, download the SunPower Monitoring Zli app from Apple App Store" or Google PlayTlstore. Data Storage 3. Sign in using account email and password. SunPower AC Modules Operating Temperature -221F to +140'F (-30'C to +60°G) Humidity(maximum) 95%, non -condensing • Certifications Warranty 10 -year Limited Warranty Certifications UL, cUL, CE, UL 61010-1 and -2, FCC Part 15 (Class B) FCc C �L I15 USTED FCC ID. YAw529027 E503346 RS -485 Communication Inverters and meters Integrated Metering • one channel of revenue -grade production metering . Two channels of consumption metering Ethernet 1 LAN (or optional WAN) port PLC PLC for SunPower AC modules WI-Fi 802.11 is/g/n 2.4 GHz and 5 GHz Cellular LTE Cat-M1/3G UMTS Zli IEEE 802.15.4 MAC, 2.4GHz ISM band Data Storage 60 days Upgrades Automatic firmware upgrades • Certifications Warranty 10 -year Limited Warranty Certifications UL, cUL, CE, UL 61010-1 and -2, FCC Part 15 (Class B) FCc C �L I15 USTED FCC ID. YAw529027 E503346 Simple and Fast Installation Integrated module -to -rail grounding Pre -assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent, even module spacing UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait with up to 8' rail span Pre -drilled rails and rail splice • Rails enable easy obstacle management Customer -Preferred Aesthetics #1 module and #1 mounting aesthetics Best -in -class system aesthetics Premium, low -profile design Black anodized components Hidden mid clamps and capped, flush end clamps Part of Superior System Built for use with SunPower DC and AC modules Best -in -class system reliability and aesthetics Optional rooftop transition flashing, rail- mountedJ-box, and wire management rail clips Combine with SunPower modules and SunPower EnergyLinkO monitoring app 4 Elegant Simplicity SunPower° InvisiMountTm is a SunPower-designed rail -based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system -level approach amplifies the aesthetic and installation benefits—for homeowners and for installers. sunpower.com V� 40* Ground Lug Assembly Mid Clamp Module' / Mid Clamp and Rail Row -to -Row Spacer Row -to -Row Grounding Clip InvisiMount InvisiMount• •• - Details Mid clamp Black oxide stainless steel 300 series 63 g (2.2 oz) End clamp Black anodized aluminum 6000 series 110 g (3.88 oz) Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) Rail splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) Rail bolt M10-1.5 x 25 mm; custom T -head SS304 18 g (0.63 oz) Rail nut M10-1.5; DIN 6923 SS304 nominal Ground lug assembly SS304; A2-70 bolt; tin-plated copper lug 106.5 g (3.75 oz) Row -to -row grounding clip SS 301 with SS 304 M6 bolts 75 g (2.6 oz) Row -to -row Black POM -grade plastic 5 g (0.18 oz) Spacer Moment: upward 548 Ibf-ft InvisiMount Component _RFD apo 25 -year product warranty Uplift 66411af Mid clamp 5 -year finish warranty UL 2703 Listed Shear 540 Ibf Uplift 899 Ibf End clamp Shear 220 Ibf Moment: upward 548 Ibf-ft Rail Moment: downward 580 Ibf-ft Moment: upward 548 Ibf-ft Rail splice Moment: downward 580 Ibf-ft Uplift 1000 Ibf L -foot Shear 390 Ibf Module' / End Clamp and Rail 4 End Clamp Rail and Rail Splice Invisilvount Operating Conditions Temperature —40° C to 90° C (-40° F to 194° F) Max. Load (LRFD) 3000 Pa uplift 6000 Pa downforce Roof Attachment Hardware Supported by Design Tool Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal interface for other roof attachments InvisilMount Warranties And Certifications 25 -year product warranty Warranties 5 -year finish warranty UL 2703 Listed Certifications Class A Fire Rated Roof Attachment Hardware 7 Refer to roof attachment hardware manufacturer's documentation. ' Module frame that is compatible with the InvisiMount %stem required for hardware interoperability. SunPower recommends that all Equinox', InvisiMount , and AC module systems always be designed using the InvisiMount Span Tables #524734. If a designer decides to instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed Professional Engineer (PE) must then stamp all calculations. If you have any questions please contact SunPower Technical Support at 1-855-977-7867. sunpoweccom © 2018 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevF All other trademarks are the property of their respective owners. Specifications included in this datasheet are subject to change without notice. PEGASUS A BETTER DAY ON THE JOB SOLAR Simple 3 -piece design for rapid installation One-piece fla press -fits or d 1 L Encapsulating design raises the water seal 0.9" above roof deck WATERTIGHT FOR LIFE Pegasus Solar's Comp Mount is a cost effective, high-quality option for rail installations on composition shingle roofs. Designed to last decades, the one-piece flashing with elevated cone means there is simply nothing to fail. 1. Drill pilot hole in center of rafter. 3. Place L -Foot over cone and install lag with washer through L -Foot. 2. Optional: Apply a "U -shape" of sealant to underside of flashing and postition under 2nd shingle course, cone over pilot hole. 4. Drive lag to required depth. Attach rail per rail manufacturer's instructions. 9.0" 1.5"1.9.. 315„ + 3.5" n n 11.6" 2.3" 2.3" 2.4" Specifications Black Comp Mount Install Kits SKU PSCR-CO PSCR-UBBO SPCR-CH L -Foot Type Closed Slot Open Slot Closed Slot L -Foot, Flashing, L -Foot, Flashing, L -Foot, Flashing, Kit Contents 5/16" x 4-1/2" SS Lag 5/16" x 4-1/2" SS Lag 5/16" x 4-1/2" SS Lag w/ EPDM washer w/ EPDM washer w/ EPDM washer, M10 Hex Bolt Finish Black L -Foot and Black Flashing Roof Type Composition Shingle Certifications IBC, ASCE/SEI 7-10, AC286 Install Application Railed Systems Compatible Rail Most Flashing Material Painted Galvalume Plus L -Foot Material Aluminum Kit Quantity 24 Boxes per Pallet 72 Patents Pending. All rights reserved. © 2019 Pegasus Solar Inc Eaton general duty cartridge fuse safety switch DG222NRB UPC:782113144221 Dimensions: • Height: 14.37 IN • Length: 7.35 IN • Width: 8.4 IN Weight: 10 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3 -Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: General duty, cartridge fused • Amperage Rating: 60A • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two -pole • Number Of Wires: Three -wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2 -Commercial Distribution • Eaton Specification Sheet - DG222NRB Certifications: • UL Listed Product compliance: No Data pe.eaton.com Eaton general duty non -fusible safety switch DG222URB UPC:782113144238 Dimensions: • Height: 14.38 IN • Length: 7.38 IN • Width: 8.69 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: Non -fusible, single -throw • Amperage Rating: 60A • Enclosure: NEMA 3R, Rainproof • Enclosure Material: Painted galvanized steel • Fuse Configuration: Non -fusible • Number Of Poles: Two -pole • Number Of Wires: Two -wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2 -Commercial Distribution • Eaton Specification Sheet - DG222URB Certifications: • UL Listed Product compliance: No Data pe.eaton.com Eaton CH main lug loadcenter CH8L125RP [1110Wf:30AiKLIL6I1>.' 1E:3 Dimensions: • Height: 3.69 IN • Length: 13 IN • Width: 11 IN Weight: 12 LB Notes:Ground bar kits priced separately. Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Warranties: • Limited lifetime Specifications: • Special Features: Cover included • Type: Main lug only • Amperage Rating: 125A • Box Size: 7r • Bus Material: Copper • Enclosure: NEMA 3R • Enclosure Material: Metallic • Feed Type: Overhead • Main Circuit Breaker: CH • Number Of Circuits: 8 • Number Of Wires: Three -wire • Phase: Single-phase • Voltage Rating: 120/240V, 208Y/120, 240V • Wire Size: #6-1/0 AWG Supporting documents: • Type CH Circuit Breakers and Loadcenters • Loadcenters and Circuit Breakers • Eatons Volume 1 -Residential and Light Commercial pe.eaton.com Eaton CH main lug loadcenter CH12L125R Dimensions: • Height: 5.19 IN • Length: 16.75 IN • Width: 14.31 IN Weight: 15.8 LB Notes:Suitable for use as service equipment when not more than six service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Rainproof panels are furnished with hub closure plates. For rainproof hubs. Warranties: • Limited lifetime Specifications: • Special Features: Cover included • Type: Main lug only • Amperage Rating: 125A • Box Size: B • Bus Material: Copper • Enclosure: NEMA 3R • Enclosure Material: Metallic • Feed Type: Overhead • Main Circuit Breaker: CH • Number Of Circuits: 12 • Number Of Wires: Three -wire • Phase: Single-phase • Voltage Rating: 120/240V • Wire Size: #6-2/0 AWG Supporting documents: • Dimensional Drawing - CH 3/4 LOADCENTER, MAIN LUG ONLY, OUTDOOR NEMA 3R, 120/240 VAC, 1 PH pe.eaton.com 4" 4.2" Box (Side View) Box (Top View) #8 by 1/2" R 1/4 0.180" 0.350" Lid (Side View) 6 3/4" 0 0 Lid (Top View) 0 0 0 0 Gasket (Top View) 0 0 6 3/4" 1/8" Gasket (Side View) t UL Listed Marine Listed UL File # E205935 (QCUP) UL Control # 92CM Material is Rigid PVC 132 cu in Volume (2163 cu cm) Screws are Zinc Plated Steel Gasket is neoprene 1 ? ! )4�V� LEM Wmomp� MP