Item 7 - PlansSHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
MAP
TONER MAP
EQUIPMENT SUMMARY
SCOPE OF WORK
69
69
SYSTEM RATING
APTOS SOLAR TECHNOLOGY DNA-120-MF23-330W PV MODULES
ENPHASE IQ7-60-2-US (240V) PV INVERTER(S)
kW DC STC
kW DC PTC
kW CEC-AC
PV-1 COVER
PV-2 SITE MAP & PV LAYOUT
PV-2.1 ROOF 1 LAYOUT
PV-2.2 ROOF 2 LAYOUT
PV-2.3 ROOF 3 LAYOUT
PV-2.4 ROOF 4 LAYOUT
PV-5.1 ELECTRICAL 1-LINE DIAGRAM
PV-5.2 ELECTRICAL WIRE CALCULATIONS
PV-6 MOUNTING DETAIL & STRUCTURAL LOAD CALCULATIONS
PV-7 SYSTEM LABELING DETAIL
PV-8 EQUIPMENT SPECIFICATION SHEETS
PV-8.1 EQUIPMENT SPECIFICATION SHEETS
PV-8.2 EQUIPMENT SPECIFICATION SHEETS
PV-8.3 EQUIPMENT SPECIFICATION SHEETS
GOVERNING CODES
TO INSTALL A SOLAR PHOTOVOLTAIC (PV) SYSTEM AT THE
MERI & ALBERT CARRIZAL RESIDENCE,
LOCATED AT 923 DOVE CREEK TRAIL IN SOUTHLAKE, 76092.
THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED
WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT.
THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES.
SHEET INDEX
22.77
20.67
17.25
2020 NATIONAL ELECTRICAL CODE
2018 INTERNATIONAL BUILDING CODE / INTERNATIONAL RESIDENTIAL CODE
UNDERWRITERS LABORATORIES (UL) STANDARDS
OSHA 29 CFR 1910.269
PROJECT LOCATION
32.953841, -97.150505
COVER
PAGE
PV-1
N
CONCRETE
DRIVEWAY
AC PV DISCONNECT
Visible, Accessible, Labeled, Lockable,
Located within 10' of Utility Meter.
UTILITY METER
SERVICE PANEL
AGGREGATE PANEL
POOL
DOVE CREE
K
T
R
A
I
L
ROOF 144° PITCH231° AZIMUTH
ROOF 233° PITCH231° AZIMUTH
ROOF 332° PITCH141° AZIMUTH
ROOF 434° PITCH51° AZIMUTH
36" FIRE WALKWAY
36" FIRE WALKWAY
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
PV
LAYOUT
PV-2
CONSTRUCTION NOTES
1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING.
3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION.
(69) (APTOS SOLAR TECHNOLOGY DNA-120-MF23-330W) SOLAR MODULES TOTAL, 22.77 kW DC STC
(69) (ENPHASE IQ7-60-2-US (240V)) INVERTER TOTAL, 17.25 kW AC.
(126) ATTACHMENT POINTS @ 72" O.C. MAX.
Roof Type = Comp Shingle, Age Unknown, 2 Layer(s)
Roof Structure = 2x6 Rafters @ 24" O.C., 12" Plywood DeckingRoof/Array #1 - 44° Pitch, 231° Azimuth
Roof/Array #2 - 33° Pitch, 231° Azimuth
Roof/Array #3 - 32° Pitch, 141° Azimuth
Roof/Array #4 - 34° Pitch, 51° Azimuth
CONSTRUCTION SUMMARY N
TOTAL ROOF AREA:4751 FT2
TOTAL SOLAR AREA:1242 FT2
TOTAL PERCENTAGE:26.1%
45'-11
4"
38'-41
4"6'-6"
21'-61
2"
17'-71
2"
8"
3'-31
4"
SOLAR MODULE
ATTACHMENT POINT
RACKING RAIL
RAFTERS @ 24" O.C.
ROOF 1
44° PITCH
231° AZIMUTH
36"
F
I
R
E
S
E
T
B
A
C
K
O
N
A
D
J
A
C
E
N
T
R
O
O
F
18" FIRE SETBACK @ RIDGES
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
(27) SOLAR MODULES
(52) ATTACHMENT POINTS @ 72" O.C. MAX.
Roof Type = Comp Shingle, Age Unknown, 2 Layer(s)
Roof Structure = 2x6 Rafters @ 24" O.C., 12" Plywood DeckingRoof/Array #1 - 44° Pitch, 231° Azimuth
CONSTRUCTION SUMMARY - ROOF 1
ROOF 1
LAYOUT
PV-2.1
N
51'-13
4"
39'-43
4"5'-3"6'-6"
12'-01
4"
11'-01
2"
SOLAR MODULE
ATTACHMENT POINT
RACKING RAIL
RAFTERS @ 24" O.C.
ROOF 2
33° PITCH
231° AZIMUTH
18" FIRE SETBACK @ RIDGES
36"
F
I
R
E
S
E
T
B
A
C
K
O
N
A
D
J
A
C
E
N
T
R
O
O
F
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
(18) SOLAR MODULES
(30) ATTACHMENT POINTS @ 72" O.C. MAX.
Roof Type = Comp Shingle, Age Unknown, 2 Layer(s)
Roof Structure = 2x6 Rafters @ 24" O.C., 12" Plywood DeckingRoof/Array #2 - 33° Pitch, 231° Azimuth
CONSTRUCTION SUMMARY - ROOF 2
ROOF 2
LAYOUT
PV-2.2
N
28'-11"
24'-61
2"3'-11"
27'-7"
21'-01
4"
5'-03
4"
1'-6"
SOLAR MODULE
ATTACHMENT POINT
RACKING RAIL
RAFTERS @ 24" O.C.
ROOF 3
32° PITCH
141° AZIMUTH
18" FIRE SETBACK @ RIDGES
3
6
"
F
I
R
E
S
E
T
B
A
C
K
O
N
A
D
J
A
C
E
N
T
R
O
O
F
3
6
"
F
I
R
E
S
E
T
B
A
C
K
O
N
A
D
J
A
C
E
N
T
R
O
O
F
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
(16) SOLAR MODULES
(25) ATTACHMENT POINTS @ 72" O.C. MAX.
Roof Type = Comp Shingle, Age Unknown, 2 Layer(s)
Roof Structure = 2x6 Rafters @ 24" O.C., 12" Plywood DeckingRoof/Array #3 - 32° Pitch, 141° Azimuth
CONSTRUCTION SUMMARY - ROOF 3
ROOF 3
LAYOUT
PV-2.3
N
32'-61
4"
16'-5"6'-91
2"9'-33
4"
16'-111
4"
11'-01
2"
8"
5'-23
4"
SOLAR MODULE
ATTACHMENT POINT
RACKING RAIL
RAFTERS @ 24" O.C.
ROOF 4
34° PITCH
51° AZIMUTH
3
6
"
F
I
R
E
S
E
T
B
A
C
K
O
N
A
D
J
A
C
E
N
T
R
O
O
F
18" FIRE SETBACK @ RIDGES
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
(8) SOLAR MODULES
(14) ATTACHMENT POINTS @ 72" O.C. MAX.
Roof Type = Comp Shingle, Age Unknown, 2 Layer(s)
Roof Structure = 2x6 Rafters @ 24" O.C., 12" Plywood DeckingRoof/Array #4 - 34° Pitch, 51° Azimuth
CONSTRUCTION SUMMARY - ROOF 4
ROOF 4
LAYOUT
PV-2.4
N
Component Notes
A Solar Panel: APTOS SOLAR TECHNOLOGY DNA-120-MF23-330W.
Typical of 69
B ENPHASE IQ7-60-2-US (240V) Microinverter. Typical of 69
C NEMA 3 Junction / Transition Box.
D Aggregate Panel - 125 A MLO - (4) 20A; (1) 15A Breakers for Inverter
Interconnection
E AC PV DISCONNECT: Lockable 100A 2-pole 240V. NEMA-3 w/90A Fuses.
Accessible, Visible, Lockable, Labeled, within 10' of Utility Meter
F Existing Load Center: 200A Bus, with 200A Main Breaker. Line Side Tap
Interconnection.
G Existing Utility Meter.
Branch Circuit One (BC1)
16 Modules; Micro-Inverters in
Parallel Source Circuit
Branch Circuit Three (BC3)
16 Modules; Micro-Inverters in
Parallel Source Circuit
Branch Circuit Five (BC5)
8 Modules; Micro-Inverters in
Parallel Source Circuit
A
B
2
1
4A
A
B
2
1
A
B
2
1
3
E
5 5
L1L2
D
C
M
G
L1L2
F
6
To Grid
Connection made with a Line
Side Tap using (2) Insulation
Piercing Hot Tap Connectors
inside Service Panel.
EXISTING GROUNDING
ELECTRODE SYSTEM
Wire and Conduit Schedule
Marker Description
Required
Conductor
Ampacity
1 (1) 6AWG Bare Cu Ground.
2 (2) 12AWG Cu PV Wire. Existing Manufacture Installed Wire 15.53
3 (2) 12AWG Enphase Wire. (1) 6AWG Bare Cu Ground.20.00
4A 3/4" EMT. (4) 10AWG Cu THWN-2. (1) 6AWG Cu THWN-2 Ground.28.17
4B 3/4" EMT. (6) 10AWG Cu THWN-2.28.17
5 1 1/4" EMT. (3) 3AWG Cu THWN-2. (1) 6AWG Cu THWN-2 Ground.86.25
6 Existing Infrastructure
SOLAR ARRAY:22.77 kW DC STC
17.25 kW AC CEC
3
3 3
3 3
Branch Circuit Two (BC2)
16 Modules; Micro-Inverters in
Parallel Source Circuit
A
B
2
1
3 3
Branch Circuit Four (BC4)
15 Modules; Micro-Inverters in
Parallel Source Circuit
A
B
2
1
3 3
4B
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
ELECTRICAL
1-LINE
DIAGRAM
PV-5.1
Isc =
Imp =
Voc =
10.51 A
10.02 A
40.27 VDC
Vmp =32.91 VDC
Voc Temp Coefficient -0.31%/ºC
TOTAL SYSTEM SIZE 22.77 kW DC STC
APTOS SOLAR TECHNOLOGY DNA-120-MF23-330W
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
n/a
n/a
n/a
n/a
=(Inverter Imax DC Input)
=(Regulated Voltage from Power Optimizer)
=(Max Isc from Power Optimizer)*(# of Strings)
69.0 A
1
1
69
-10ºC
-0.31%/ºC
=(Max Voltage from Inverter)
ELECTRICAL
WIRE
CALCULATIONS
PV-5.2
1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.
2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90ºC WET ENVIRONMENT.
3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY
TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.
4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL
COMPLY WITH NEC 110.26.
5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL
FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL
APPLICABLE CODES AND STANDARDS.
6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE
CONTRACTOR SHALL SIZE THEM ACCORDINGLY.
7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.
8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE
SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION.
9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG
OR ILSCO GBL-4DBT LAY-IN LUG.
10.) THE DC SIDE OF THE PV SYSTEM IS UNGROUNDED AND SHALL COMPLY WITH NEC 690.35.
11.) INSTALLATION SHALL BE ACCORDING TO THE 2017 NATIONAL ELECTRIC CODE AND ALL STATE
AND LOCAL STANDARDS AND CODES.
12.) LABELS SHALL BE INSTALLED ON ALL NECESSARY EQUIPMENT AS PER NEC, INCLUDING
INVERTERS, SWITCHES, LOAD CENTERS AND ALL OTHER ENCLOSURES.
13.)ALL ELECTRICAL WORK WILL BE INSTALLED AND INSPECTED BY A MASTER ELECTRICIAN AND
ALL LOCAL AUTHORITIES.
14.) PROPERLY SIZED SURGE PROTECTION SHALL BE INSTALLED ON THE LOAD SIDE (SOLAR SIDE)
OF THE FUSED AC DISCONNECT.
15.) CONTRACTOR IS RESPONSIBLE FOR ENSURING INSTALLATION IS FIELD VERIFIED, AND IS
INSTALLED PER NEC REQUIREMENTS & MANUFACTURERS DESIGN SPECIFICATIONS.
16.) CONTINUOUS GROUND IS REQUIRED. IRREVERSIBLE COMPRESSION CLAMPS ARE REQUIRED
FOR ALL GROUND SPLICES.
17.) IF APPLICABLE, CTs MOUNTED IN VERTICAL OR HORIZONTAL POSITION ON MOUNTING BAR
PROVIDED IN CT ENCLOSURE. CTs MOUNTED EQUAL DISTANCE APART & CENTERED.
18.) ALL EQUIPMENT (TERMINALS,LUGS, & DEVICES) ARE LISTED & IDENTIFIED FOR 75°C
CONDUCTORS MINIMUM.
19.) ALL EQUIPMENT SHALL BE LISTED & IDENTIFIED FOR APPLICATION. PV MODULES SHALL BE
CERTIFIED TO UL 1703. INVERTERS, CONVERTERS, & COMBINERS SHALL BE CERTIFIED TO UL1741.
ELECTRICAL NOTES
DC STRING CALCULATIONS DC SYSTEM SPECIFICATIONS
Operating Current
Operating Voltage
Max. System Voltage
Short Circuit Current
AC SYSTEM SPECIFICATIONS
AC Output Current
Operating AC Voltage 240 V
CONFIGURATION
Modules per String
Strings per Inverter
Number of Inverters
Record low temp
Voc Temp Coefficient
SYSTEM SIZE
AC System Size
DC System Size 22.77
17.25 kW
kW
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS
#5 Aggregate Panel Output Wire Ampacity Calculation
Output Circuit OCP Calc.
(Inverter Imp)*(Total # of Inverters)*(1.25) = 86.25 A
Agg Panel Imax (Inverter Imp)*(Total # of Inverters) = 69.0 A
AWG #3, (Derated Amps=100)*(Temp Der.=0.91)*(CND Fill Der.=1) = 91.0 A
91.0 A > 69.0 A, therefore AC wire size is valid.
#4A,4B Junction Box 1 Output Wire Ampacity Calculation
Using largest ampacity of separate branches for calculation = 16.0 A
AWG #10, (Derated Amps=35)*(Temp Der.=0.71)*(CND Fill Der.=0.8) = 19.9 A
19.9 A > 16.0 A, therefore AC wire size is valid.
#3 Microinverter Output Wire Ampacity Calculation - Branch 1, 2, 3, 4, 5
Branch Output Circuit OCP Calc. (Inverter Imp)*(# of Inverters)*(1.25) = 20.0 A
Using largest ampacity of separate branches for calculation
Branch Output Circuit Imax (Inverter Imp)*(# of Inverters) = 16.0 A
AWG #12, (Derated Amps=25)*(Temp Der.=0.91)*(CND Fill Der.=1) = 22.75 A
22.75 A > 16.0 A, therefore AC wire size is valid.
#2 Existing Manufactured Installed AWG #12 Wire
SOLAR MODULE
IRONRIDGE RAIL
ROOF MATERIAL
L - FOOT
RT MINI ATTACHMENT
66.34 in.
COMPOSIT
I
O
N
R
O
O
F
Existing Roof Structure
L-Foot
IronRidge Rail
1'-512"9'-10 14"9'-834"
23'-8"
2x6 RAFTER
@ 24" O.C.
2x6 CEILING JOIST
@ 24" O.C.
2x4 PURLIN SUPPORT
@ 48" O.C.
2x6 PURLIN
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
ROOF FRAMING DETAIL 1SCALE: NTS
MOUNTING DETAIL 3SCALE: NTS
MOUNTING METHOD 2SCALE: NTS
MOUNTING
DETAIL &
LOAD CALCS
PV-6
LOAD CALCULATIONS (ROOF - 1)
TOTAL # OF
MODULES 27
TOTAL # OF
STANDOFFS 52
LINEAR FT OF
RAIL 207 FT
MODULE WEIGHT 43 LBS
STANDOFF
WEIGHT 2.0 LBS
RAIL WEIGHT
LBS/FT 0.9 LBS
TOTAL MODULE
WEIGHT 1161 LBS
TOTAL STANDOFF
WEIGHT 104 LBS
TOTAL RAIL
WEIGHT 186 LBS
TOTAL ARRAY
WEIGHT 1451 LBS
TOTAL ARRAY
AREA 472.5 FT²
POINT LOAD 27.9 LBS
DEAD LOAD 3.07 LBS/FT²
LOAD CALCULATIONS (ROOF - 3)
TOTAL # OF
MODULES 16
TOTAL # OF
STANDOFFS 25
LINEAR FT OF
RAIL 176 FT
MODULE WEIGHT 43 LBS
STANDOFF
WEIGHT 2.0 LBS
RAIL WEIGHT
LBS/FT 0.9 LBS
TOTAL MODULE
WEIGHT 688 LBS
TOTAL STANDOFF
WEIGHT 50 LBS
TOTAL RAIL
WEIGHT 158 LBS
TOTAL ARRAY
WEIGHT 896 LBS
TOTAL ARRAY
AREA 280.0 FT²
POINT LOAD 35.9 LBS
DEAD LOAD 3.20 LBS/FT²
STRUCTURAL NOTES:
1. INSTALLATION OF IRON RAIL CONNECTION SYSTEM SHALL BE PERFORMED IN
COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS & CRITERIA.
2. THE EXISTING ROOF SUPPORT FRAMING STRUCTURE HAS SUFFICIENT
CAPACITY TO WITHSTAND NEW SOLAR ARRAY SYSTEM AS PRESCRIBED. ALL
BUILDING/ROOF STRUCTURE FRAMING COMPONENTS ARE EXISTING,
DESIGNED BY OTHERS, ASSUMED TO BE IN GOOD CONDITION, MINIMUM
GRADE #2 SOUTHERN PINE OR BETTER, REMAIN IN ORIGINAL STATE & IT'S
INTEGRITY HAD NOT BEEN COMPROMISED BY MODIFICATIONS, CUT OFFS,
TERMITES, BLACK MOLD & ETC.
ALL FLASHINGS SEALED WITH
CONSTRUCTION & FLASHING SEALANT
OR METAL ROOF SEALANT
(TT-S-00230C (TYPE II) CLASS A, ASTM
C-920 TYPE S, GRADE NS, CLASS 25,
LOAD CALCULATIONS (ROOF - 2)
TOTAL # OF
MODULES 18
TOTAL # OF
STANDOFFS 30
LINEAR FT OF
RAIL 144 FT
MODULE WEIGHT 43 LBS
STANDOFF
WEIGHT 2.0 LBS
RAIL WEIGHT
LBS/FT 0.9 LBS
TOTAL MODULE
WEIGHT 774 LBS
TOTAL STANDOFF
WEIGHT 60 LBS
TOTAL RAIL
WEIGHT 130 LBS
TOTAL ARRAY
WEIGHT 964 LBS
TOTAL ARRAY
AREA 315.0 FT²
POINT LOAD 32.1 LBS
DEAD LOAD 3.06 LBS/FT²
LOAD CALCULATIONS (ROOF - 4)
TOTAL # OF
MODULES 8
TOTAL # OF
STANDOFFS 14
LINEAR FT OF
RAIL 52 FT
MODULE WEIGHT 43 LBS
STANDOFF
WEIGHT 2.0 LBS
RAIL WEIGHT
LBS/FT 0.9 LBS
TOTAL MODULE
WEIGHT 344 LBS
TOTAL STANDOFF
WEIGHT 28 LBS
TOTAL RAIL
WEIGHT 47 LBS
TOTAL ARRAY
WEIGHT 419 LBS
TOTAL ARRAY
AREA 140.0 FT²
POINT LOAD 29.9 LBS
DEAD LOAD 2.99 LBS/FT²
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
APPLY TO:
PV SYSTEM BREAKER
6 1/2"
APPLY TO:
DC DISCONNECTS
SOLAR DC DISCONNECT
REQ'D BY: NEC 690.17
1/
2
"
REQ' BY: NEC 690.14(C)(2)
APPLY TO:
SOLAR CONDUIT
REQ'D BY: AHJ
APPLY TO:
AC DISCONNECTS
6 1/2"
SOLAR AC DISCONNECT
MAIN SERVICE PANEL
1/
2
"
REQ'D BY: NEC 690.54
SCALE: 1" = 4"
7 1/2"
WARNING
ELECTRIC SHOCK HAZARD. DO
NOT TOUCH TERMINALS.
TERMINALS ON BOTH THE LINE
AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN
POSITION.
APPLY TO:
INVERTER
4
1
/
2
"
8 1/4"
GRID TIED PHOTOVOLTAIC
POWER SOURCE
OPERATING CURRENT: xx A
OPERATING VOLTAGE: 400 V
MAX SYSTEM VOLTAGE: 480 V
SHORT CIRCUIT CURRENT: 30.0 A
MAX INVERTER OUTPUT:
5.0 kW, 21.0 A, 240 VAC
APPLY TO:
INVERTER
5"
6 3/4"
APPLY TO:
SOLAR LOAD CENTER
PHOTOVOLTAIC SYSTEM
DISCONNECT
AC CURRENT: 69.0 A
VOLTAGE: 240 VAC
REQ'D BY: NEC 690.35(F)
2
1
/
2
"
UNGROUNDED ARRAYS ONLY
JUNCTION BOXES
COMBINER BOXES
DC DISCONNECTS
INVERTERS
7 1/4"
REQ'D BY: NEC 690.64(B)(7)
THIS ELECTRIC SERVICE IS ALSO
SERVED BY A PHOTOVOLTAIC
SYSTEM
2"
8"
REQ'D BY: AHJ
CAUTION
DO NOT INSTALL ADDITIONAL
LOADS IN THIS PANEL
APPLY TO:
MAIN SERVICE PANEL
2"
6 1/4"
RED'Q BY: NEC 690.53
WARNING
INVERTER OUTPUT
CONNECTION. DO NOT
RELOCATE THIS
OVERCURRENT DEVICE
7 1/2"
3
1
/
4
"
REQ'D BY: NEC 690.5(C)
7 1/2"
3
3
/
4
"
CAUTION
SOLAR PV SYSTEM MAY
REMAIN ENERGIZED AFTER
DISCONNECT DURING
DAYLIGHT HOURS.
3
1
/
4
"
6 3/4"
CAUTION: SOLAR CIRCUIT
REQ'D BY: NEC 690.56(B)
1/
2
"
APPLY TO:
PV SYSTEM BREAKER
WARNING
IF GROUND FAULT IS INDICATED,
THE NORMALLY GROUNDED
CONDUCTORS MAY BE
ENERGIZED AND UNGROUNDED.
7 1/2"
REQ'D BY: NEC 690.64(B)(2)
WARNING
ELECTRIC SHOCK HAZARD.
THE DC CONDUCTORS OF THE
PV SYSTEM ARE
UNGROUNDED AND MAY BE
ENERGIZED.
APPLY TO:
DISCONNECTS
SOLAR LOAD CENTERS
COMBINER BOXES
3
3
/
4
"
> RED BACKGROUND
> WHITE LETTERING
> MIN. 3/8" LETTER HEIGHT
> ALL CAPITAL LETTERS
> ARIAL OR SIMILAR FONT
> REFLECTIVE, WEATHER RESISTANT
MATERIAL, UL 969
SIGNAGE REQUIREMENTS
REQ' BY: NEC 690.14(C)(2)
SYSTEM
LABELING
DETAIL
PV-7
REQ'D BY: NEC 690.56(C)(1)(b)13
6 3/4"
PHOTOVOLTAIC SYSTEM
EQUIPPED WITH
RAPID SHUTDOWN1
3
/
4
"
LOCATED WITHIN 3 FT FROM PV
SYSTEM DISCONNECT SWITCH
1211109
5 6 7 8
4321
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
EQUIPMENT
SPECIFICATION
SHEETS
PV-8
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
EQUIPMENT
SPECIFICATION
SHEETS
PV-8.1
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
EQUIPMENT
SPECIFICATION
SHEETS
PV-8.2
SHEET NUMBER
NABCEP: PV-102216-015022
BRANDON DE LA TORRE
DESIGN & DRAFTING BY:
A10/30/2020ORIGINAL
REVDATE
REVISIONS
DESCRIPTION
CONTRACTOR
PROJECT NAME
CA
R
R
I
Z
A
L
-
9
2
3
D
O
V
E
C
R
E
E
K
T
R
L
92
3
D
O
V
E
C
R
E
E
K
T
R
A
I
L
SO
U
T
H
L
A
K
E
,
TX
,
76
0
9
2
ES
I
I
D
#
:
10
4
4
3
7
2
0
0
0
6
3
1
7
2
4
5
SHEET SIZEANSI B
11"x17"
SHEET NAME
1800 S. LOOP 288, STE 396 #105
DENTON, TX 76205
NABCEP: PV-102216-015022
TECL# 31393
T C
www.tacsolarandac.com
B1/5/2021SETBACKS ADDED
EQUIPMENT
SPECIFICATION
SHEETS
PV-8.3