Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Item 9A - Plans
PROJECT SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 Carroll Senior High School Tennis Southlake,TX LighƟng System Pole / Fixture Summary Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit P1 50'50'2 TLC-LED-900 1.78 kW A P2 50'50'2 TLC-LED-900 1.78 kW A 50'2 TLC-LED-900 1.78 kW B P3 50'50'2 TLC-LED-900 1.78 kW B P4 50'50'2 TLC-LED-900 1.78 kW B 50'2 TLC-LED-900 1.78 kW D P5 50'50'2 TLC-LED-900 1.78 kW B 50'2 TLC-LED-900 1.78 kW A 50'2 TLC-LED-900 1.78 kW C 50'2 TLC-LED-900 1.78 kW D P6 50'50'2 TLC-LED-900 1.78 kW C 50'2 TLC-LED-900 1.78 kW A P7 50'50'2 TLC-LED-900 1.78 kW C P8 50'50'2 TLC-LED-900 1.78 kW D 50'2 TLC-LED-900 1.78 kW C P9 50'50'2 TLC-LED-900 1.78 kW D 9 32 28.48 kW Circuit Summary Circuit Description Load Fixture Qty A Tennis 1 7.12 kW 8 B Tennis 2 7.12 kW 8 C Tennis 3 7.12 kW 8 D Tennis 4 7.12 kW 8 Fixture Type Summary Type Source Wattage Lumens L90 L80 L70 Quantity TLC-LED-900 LED 5700K - 75 CRI 890W 89,600 >120,000 >120,000 >120,000 32 Light Level Summary Calculation Grid Summary IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty Blanket Grid Horizontal 8.35 0 84 0.00 A,B,C,D 32 Spill_Residential Horizontal 0 0 0 0.00 A,B,C,D 32 Spill_Residential Max Candela (by Fixture)0.01 0 0.38 0.00 A,B,C,D 32 Spill_Residential Max Vertical Illuminance Metric 0 0 0 0.00 A,B,C,D 32 Tennis-1 Horizontal Illuminance 52 38 61 1.61 1.37 A 8 Tennis-2 Horizontal Illuminance 54.9 43 68 1.59 1.28 B 8 Tennis-3 Horizontal Illuminance 54.5 48 68 1.40 1.14 C 8 Tennis-4 Horizontal Illuminance 55.5 48 69 1.42 1.16 D 8 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 51 45 43 44 52 46 61 45 61 55 48 56 57 59 59 48 55 57 59 60 46 60 45 59 57 52 45 38 42 53 P1 P2 P6 P5 59 ' 53' 60 ' 54' 61 ' 56' 59 ' 56' SCALE IN FEET 1 : 20 0'20'40' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS1P150'-50'TLC-LED-900 2 2 0 2 P2, P6 50'-50'TLC-LED-900 4 2 2 1 P5 50'-50'TLC-LED-900 4/4*2 6 4 TOTALS 18 8 10 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name: Tennis-1 Size: 2 Court - 12' Spacing Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:50 Scan Average:52.03 Maximum:61 Minimum:38 Avg / Min:1.37 Guaranteed Max / Min:2 Max / Min:1.61 UG (adjacent pts):0.00 CU:0.86 No. of Points:30 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 8 Total Load: 7.12 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 0.01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 2 2 2 2 2 2 1 1 1 2 2 4 5 5 5 6 6 6 5 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 3 6 9 11 12 14 17 18 17 14 12 11 10 11 15 19 20 20 21 21 21 20 19 18 14 7 3 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 8 18 28 32 35 40 41 41 41 38 33 31 27 26 33 38 37 40 39 37 39 40 38 37 30 15 5 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 12 29 47 50 53 56 53 50 50 51 47 48 41 36 43 52 50 45 43 43 43 45 50 52 43 21 6 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 11 31 50 60 65 58 51 49 50 57 57 54 42 33 40 53 59 54 43 40 43 54 61 57 43 19 4 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 7 25 44 59 67 63 53 49 54 60 59 50 35 24 31 47 61 61 50 45 50 62 65 54 35 13 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 20 47 59 62 61 55 52 54 58 60 56 32 14 26 50 59 61 56 53 56 62 63 57 32 8 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 16 48 60 56 54 53 51 51 54 60 59 31 7 23 49 58 56 56 57 59 59 61 59 32 5 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 16 48 61 55 52 52 51 51 54 60 60 32 8 22 49 59 55 56 57 59 60 62 60 33 6 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 18 48 60 60 58 54 53 55 59 60 58 35 15 26 49 60 58 55 52 57 64 65 59 35 10 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 6 23 44 58 65 61 52 50 56 62 62 52 38 26 34 48 59 60 50 44 47 59 65 57 39 17 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 10 30 49 58 62 58 51 51 54 61 60 56 47 40 47 58 61 57 47 41 42 51 61 60 48 24 6 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 13 34 56 61 63 67 66 65 64 64 60 61 57 52 60 68 65 60 55 53 52 52 56 60 53 29 10 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 4 16 38 60 67 75 84 84 82 83 79 70 67 64 58 70 73 74 78 74 70 71 73 68 67 58 32 13 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 3 15 36 60 64 69 71 72 73 74 72 68 67 63 57 66 72 70 68 68 67 69 71 67 67 60 33 11 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 11 33 54 63 67 58 52 53 53 63 71 64 53 47 55 65 69 62 53 51 51 59 67 65 54 31 8 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 6 26 47 62 68 62 50 48 57 71 74 57 39 31 43 59 70 66 54 46 47 61 69 64 50 27 5 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 21 51 63 62 59 53 52 58 66 62 55 33 19 36 59 65 63 52 46 50 60 66 67 57 25 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 18 52 64 56 52 51 51 53 54 55 53 28 12 35 59 59 52 48 46 50 55 60 67 60 25 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 18 51 61 56 53 51 50 49 49 56 51 24 12 36 57 57 52 48 43 47 57 63 66 60 25 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 4 20 48 59 62 60 53 52 55 56 56 50 25 16 37 57 61 61 52 40 45 60 72 66 56 25 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 7 25 44 58 66 60 51 54 63 72 64 48 31 25 38 54 68 67 53 46 45 58 72 65 48 25 6 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 11 31 50 60 64 54 50 52 59 72 69 57 42 36 46 60 69 64 53 53 50 54 66 64 51 28 7 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 12 29 48 50 55 54 53 53 55 60 58 57 45 40 47 55 56 60 55 50 49 52 49 50 45 25 7 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 9 19 30 33 35 39 41 42 43 40 36 36 30 26 31 34 33 36 34 29 26 24 25 29 26 14 6 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 3 7 10 11 10 11 14 15 14 12 12 12 11 11 10 10 9 7 6 5 4 3 5 7 8 6 3 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 1 1 1 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P1 P3P2 P6 P7 P9 P4 P8 P5 59 ' 53' 18 3 ' 164' 60 ' 54' 59 ' 165' 59 ' 164' 18 4 ' 57' 18 4 ' 52' 61 ' 56' 59 ' 56' SCALE IN FEET 1 : 100 0'100'200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4P1, P3, P7 P9 50'-50'TLC-LED-900 2 2 0 4 P2, P4, P6 P8 50'-50'TLC-LED-900 4 4 0 1 P5 50'-50'TLC-LED-900 4/4*8 0 9 TOTALS 32 32 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name: Blanket Grid Size: 2 Court - 12' Spacing Spacing: 10.0' x 10.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:8.35 Maximum:84 Minimum:0 Avg / Min:- Max / Min:- UG (adjacent pts):565.78 CU:1.00 No. of Points:3596 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 32 Total Load: 28.48 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. NOTES:Blue contour line represents 0.01FC Horizontal ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 55 45 44 51 54 55 67 44 59 66 57 52 46 55 67 56 53 43 56 66 52 68 46 56 66 55 61 50 52 50 59 ' 53' 60 ' 52' 61 ' 56' 58 ' 56'P4 P3P2 P5 SCALE IN FEET 1 : 20 0'20'40' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2P2, P4 50'-50'TLC-LED-900 4 2 2 1 P3 50'-50'TLC-LED-900 2 2 0 1 P5 50'-50'TLC-LED-900 4/4*2 6 4 TOTALS 18 8 10 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name: Tennis-2 Size: 2 Court - 12' Spacing Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:50 Scan Average:54.92 Maximum:68 Minimum:43 Avg / Min:1.28 Guaranteed Max / Min:2 Max / Min:1.59 UG (adjacent pts):0.00 CU:0.88 No. of Points:30 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 8 Total Load: 7.12 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 51 57 52 50 48 50 68 50 57 56 56 54 52 52 62 57 54 52 51 62 50 64 51 59 59 51 55 51 53 50 67 ' 54' 58 ' 56' 58 ' 53' 67 ' 55'P6 P8P7 P5 SCALE IN FEET 1 : 20 0'20'40' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS1P550'-50'TLC-LED-900 4/4*2 6 2 P6, P8 50'-50'TLC-LED-900 4 2 2 1 P7 50'-50'TLC-LED-900 2 2 0 4 TOTALS 18 8 10 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name: Tennis-3 Size: 2 Court - 12' Spacing Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:50 Scan Average:54.48 Maximum:68 Minimum:48 Avg / Min:1.13 Guaranteed Max / Min:2 Max / Min:1.40 UG (adjacent pts):0.00 CU:0.86 No. of Points:30 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 8 Total Load: 7.12 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 54 57 48 50 56 53 67 49 62 69 59 53 50 52 56 58 54 50 49 57 49 65 51 67 59 50 56 53 56 56 57 ' 52' 67 ' 53' 57 ' 56' 68 ' 57' P9 P4 P8 P5 SCALE IN FEET 1 : 20 0'20'40' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2P4, P8 50'-50'TLC-LED-900 4 2 2 1 P5 50'-50'TLC-LED-900 4/4*2 6 1 P9 50'-50'TLC-LED-900 2 2 0 4 TOTALS 18 8 10 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name: Tennis-4 Size: 2 Court - 12' Spacing Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:50 Scan Average:55.52 Maximum:69 Minimum:48 Avg / Min:1.15 Guaranteed Max / Min:2 Max / Min:1.42 UG (adjacent pts):0.00 CU:0.88 No. of Points:30 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 8 Total Load: 7.12 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 P1 P3P2 P6 P7 P9 P4 P8 P5 SCALE IN FEET 1 : 100 0'100'200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4P1, P3, P7 P9 50'-50'TLC-LED-900 2 2 0 4 P2, P4, P6 P8 50'-50'TLC-LED-900 4 4 0 1 P5 50'-50'TLC-LED-900 4/4*8 0 9 TOTALS 32 32 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name:Spill_ResidenƟal Spacing: 10.0' Height: 0.0' above grade ILLUMINATION SUMMARY HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:0.0000 Maximum:0.00 Minimum:0.00 No. of Points:52 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 32 Total Load: 28.48 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 P1 P3P2 P6 P7 P9 P4 P8 P5 SCALE IN FEET 1 : 100 0'100'200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4P1, P3, P7 P9 50'-50'TLC-LED-900 2 2 0 4 P2, P4, P6 P8 50'-50'TLC-LED-900 4 4 0 1 P5 50'-50'TLC-LED-900 4/4*8 0 9 TOTALS 32 32 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name:Spill_ResidenƟal Spacing: 10.0' Height: 0.0' above grade ILLUMINATION SUMMARY MAX VERTICAL FOOTCANDLES EnƟre Grid Scan Average:0.0000 Maximum:0.00 Minimum:0.00 No. of Points:52 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 32 Total Load: 28.48 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P1 P3P2 P6 P7 P9 P4 P8 P5 SCALE IN FEET 1 : 100 0'100'200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4P1, P3, P7 P9 50'-50'TLC-LED-900 2 2 0 4 P2, P4, P6 P8 50'-50'TLC-LED-900 4 4 0 1 P5 50'-50'TLC-LED-900 4/4*8 0 9 TOTALS 32 32 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX GRID SUMMARY Name:Spill_ResidenƟal Spacing: 10.0' Height: 0.0' above grade ILLUMINATION SUMMARY CANDELA (PER FIXTURE) EnƟre Grid Scan Average:0.0137 Maximum:0.38 Minimum:0.00 No. of Points:52 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 89,600 lumens No. of Luminaires: 32 Total Load: 28.48 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-900 >120,000 >120,000 >120,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LAYOUT Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Addison Ardolino • File #136663A • 22-Jun-20 Tennis-1 2 Court - 12' Spacing P1 P3P2 P6 P7 P9 P4 P8 P5 Tennis-2 2 Court - 12' Spacing Tennis-3 2 Court - 12' Spacing Tennis-4 2 Court - 12' Spacing SCALE IN FEET 1 : 80 0'80'160' Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Carroll Senior High School Tennis Southlake,TX EQUIPMENT LAYOUT INCLUDES: · Tennis-1 · Tennis-2 · Tennis-3 · Tennis-4 Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE 4 P1, P3 P7, P9 50'-50'TLC-LED-900 2 4 P2, P4 P6, P8 50'-50'TLC-LED-900 4 1 P5 50'-50'TLC-LED-900 4/4* 9 TOTALS 32 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon SINGLE LUMINAIRE AMPERAGE DRAW CHART Ballast SpeciĮcaƟons(.90 min power factor)Line Amperage Per Luminaire(max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3