Loading...
SB Item 6 - PresentationMaster Sign Plan for Yates Country Store MSP20-0003 MSP20-0002 APPLICANT:Baker Signs REQUEST: Approval of a Master Sign Plan for Yates Country Store LOCATION: 2190 E. Dove Road Aerial View Site Plan (ZA20-0030) Signage Site Plan Sign A –Gas Canopy Proposed Sign Proposed Sign Ordinance 704 Sign ‘A’ Gas Canopy •Max.letter ht.:18” •Total façade width: 54’ •Total sign width: 8’ 7” •Total sign area: 15.4 sf •Sign not located within 75% of façade width •Internally lit channel cut letters: white •With the addition of the gas canopy signage (4), the total number of attached signs proposed is five (5); three (3 N. Kimball Ave.) and two (2) E. Dove Rd.) on 2 street fronts. •Max letter height: 16“ •Total façade width: 54’ -Total sign width: 40.5’ -Total sign area: 37.8 sf -Sign to be located within 75% of façade width •Internally illuminated channel cut letters are required to be white, ivory, black, grey, beige or similar neutral colors •A maximum of two (2) attached signs are allowed per site and only one (1) per street front. Sign B –Gas Canopy Proposed Sign Proposed Sign Ordinance 704 Sign ‘B’ Gas Canopy •Max. logo ht.:18” •Total façade width: 26’ •Total logo area: 1.75 sf •Total sign width: 11’ 6” •Total area: 17.5 sf •Sign not located within 75% of façade width •Logo/stripe color: Red •With the addition of the gas canopy signage (4), the total number of attached signs proposed is five (5); three (3 N. Kimball Ave.) and two (2) E. Dove Rd.) on 2 street fronts. •Logo ht.: 20” •Total façade width: 26’ -Total logo area: 2.18 sf -Total sign width: 19.5’ -Total area: 19.5 sf •Sign located within 75% of façade width •Logo may be any color •A maximum of two (2) attached signs are allowed per site and only one (1) per street front. Sign C –Gas Canopy Proposed Sign Proposed Sign Ordinance 704 Sign ‘C’ Gas Canopy •Max.letter ht.:18” •Total façade width: 54’ •Total sign width: 8’ 7” •Total sign area: 15.4 sf •Sign not located within 75% of façade width •Internally lit channel cut letters: white •With the addition of the gas canopy signage (4), the total number of attached signs proposed is five (5); three (3 N. Kimball Ave.) and two (2) E. Dove Rd.) on 2 street fronts •Max letter height: 16“ •Total facade width: 54’ -Total sign width: 40.5’ •-Total sign area: 37.8 sf •Sign to be located within 75% of façade width •Internally illuminated channel cut letters are required to be white, ivory, black, grey, beige or similar neutral colors. •A maximum of two (2) attached signs are allowed per site and only one (1) per street front. Sign D –Gas Canopy Proposed Sign Proposed Sign Ordinance 704 Sign ‘D’ Gas Canopy •Max. logo ht.:18” •Total façade width: 26’ •Total logo area: 1.75 sf •Total sign width: 11’ 6” •Total area: 17.5 sf •Sign not located within 75% of façade width •Logo/stripe color: red •With the addition of the gas canopy signage (4), the total number of attached signs proposed is five (5); three (3 N. Kimball Ave.) and two (2) E. Dove Rd.) on 2 street fronts. •Logo height: 20” •Total façade width: 26’ •Total logo area: 2.18 sf •Total sign width: 19.5’ •Total area: 19.5 sf •Sign located within 75% of façade width •Logo may be any color •A maximum of two (2) attached signs are allowed per site and only one (1) per street front. Sign E –Gas Pricing Monument Sign Proposed Sign Brief Description Sign Ordinance 704 Sign ‘E’ Gas Pricing Monument Sign •Max. total ht. for gas monument sign: 7 ft. 7 ¼ in •Max. sign structure ht.: 5 ft. 11 ½ in •Max. sign face ht.: 5’ 11 ½” •Max sign face area: 70.25 sf per sign face •Max sign structure area: 72.25 sf •Masonry surround: width not noted •Distance from property line: 5’ •Address numbers: not provided •Max. total ht. for gas monument sign: 6’ 6” •Max. sign structure ht.: 5’ •Max. sign face ht.: 4’ •Max sign face area: 70 sf per sign face •Max sign structure area: 70 sf •Masonry surround: min. 6” •Distance from property line: 15’ •Address numbers: 6” min. located on top 20% of sign structure Double sided monument sign Sign F –Pole Sign Proposed Sign Brief Description Sign Ordinance 704 Sign ‘F’ Pole Sign •Reface one existing gas pricing pole sign at the intersection of E. Dove Road and N. Kimball Avenue. •Note: Sign may need to be located if monument sign location conflicts with the existing pole sign location (due to sight line requirement) •Pole signs prohibited Sign G –Attached Building Sign Proposed Sign Brief Description Sign Ordinance 704 Sign ‘G’ Attached Building Sign •Roof Sign •Letter ht.; 12” •Total sign width: 18’8” •Total sign area: 18.66 sf •Letter color: Red, internally illuminated •Roof sign prohibited without city Council approval •Max letter height: 16“ •Total facade width: 63’ •Total sign width: 47’-4” •Total sign area: 53 sf •Sign located within 75% of façade width •Internally illuminated channel cut letters are required to be white, ivory, black, grey, beige or similar neutral colors. Site Photos View north from E. Dove Road View north from E. Dove RoadView west from N. Kimball Avenue View south from N. Kimball Avenue Questions?