Loading...
SB Item 5 - Proposed Signage800.627.4460 440.209.6200 t h e M Cg r o u p.c o m S I T E A D D R E S S : 2 5 1 E S H 1 1 4 S o u t h l a ke , TX 76 0 9 2 OWN E R’S S COPE O F WO RK : M a r ri o tt Co n t a c t : M C Pro j e c t M a n a g e r : Ti m Fe n s ke M C S a l e s : J a m e s Pea ke S IGN PACKAG E : (2 ) LET TE R SETS - WEST & EA ST ELEVAT IONS (1 ) LET TE R SET - NORT H ELEVAT ION (2 ) M ON U ME NT LET TERSETS PERMIT T ING D E TAILS: TB D CUSTO M E R APPR OVA L / S I GNATUR E: SIGN ATURE:DAT E: - O w ne r to provi de (1) prim ary c ircuit (12 0v ) for EAC H s ig n loc ation. - Sign con tra ct o r is re s ponsibl e for all s eco nda r y w irin g. I f p r imary i s not prese nt at ti me o f in s tal l, th e own er is resp ons ib le f or makin g t he fina l c onnec ti o n. - Ow ne r is t o pro v ide un r estric te d access t o th e are a b ehin d wh ere each s ig n is l oca ted . - T he acc ess pa ne l is to b e ap pro x . 24 ” x 36”. - 5 /8” pl y w o od bl o cking i s to be prov id ed b eh in d wh ere each s ign a nd lighting i s to be insta ll ed. PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY:CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 2 Scale: 1/16”=1’-0”W E S T E LE V ATION PAGE NO. SITE SURVEY REQUIRED 02/21/20 C\L ±189 ’-6” ±19’-6 ” CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: 584990 ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 2 PAGE NO. 04/02/20 ALL SIGN SIZES HAVE BEEN CALCULATED OFF ARCHITECTURAL PRINTS AS SHOWN 6 0 IN CH S T A C K E DA 57’-8 ” 04/02/20 KW Added plywood backing 2 ’-6”2’-6” 76’-6” 251 E SH 114 Southlake, TX 76092 OPTION A JAMES PEAKE / TIM FENSKE PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: Scale: 1/16”=1’-0”E A ST E L E V ATION CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 3 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 3 PAGE NO. 04/02/20 C\L ±189’-6 ”±26’-0” 5’-6”5’-6” 76’-6” 57’-8” ALL SIGN SIZES HAVE BEEN CALCULATED OFF ARCHITECTURAL PRINTS AS SHOWN 60 I NC H ST A C K EDB 04/02/20 KW Added plywood backing 251 E SH 114 Southlake, TX 76092 OPTION A SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: Scale: 3/16”=1’-0”FACE L I T CHAN NE L LE T T ER S 6 0 INC H ST AC K ED TYPICAL FRAMED WALL MOUNTING DETAIL 1/2” WALL SHEATHING 2X4 WOOD BLOCKING BETWEEN STUDS; ATTACH BLOCKING AT EACH END TO STUDS WALL STUD ON 16” CENTERS 3/8” DIA. THRU BOLT W/ NUT, FLAT & LOCK WASHERS typical 1/2” DIA SPACER FROM BACK OF LETTER TO FACE OF BLOCKING typical (2) TWO l e tterset s requ ire d for WES T AND E AST e levati onQUANTITY: FACES:3/16" #7328 whit e a cr ylic 3/16" #7328 whit e a cr ylic RETA INERS: T R IMCA P: 3/4" alum . r etainers - p aint ed black (’D’ l ogo o nly) 1” Black je wel i te (DELTA HOTELS, UN D E R SCORE, MARRIO TT) R E TURNS:5 ” d eep .080 alum . - in side s pre-painte d W hi te ; Outsides pa in ted Bla ck BA CKS: W ALL M ATERI AL: .0 6 3 Alu m. - pre-pa in ted W hi te Not provided at t hi s tim e ILLUM.:GE Wh it e LED as re q u i r ed by m anu fac turer ; Re mote Po wer sup p lies EAS T E L E VATION LET TERS ET ONLY Le t ters to be pr e-wired d ur ing a sp ecial t rip. "D" log o, se c ond ar y wire to be b ro ught out t h ro ugh t he bottom of the lo go so it can be acc essed from the guest room r ather than the r oof INSTALL: CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 4 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 4 PAGE NO. 04/02/20 A B 161.6 square feet 161.6 sq f t 18’-8-1 /4” 1 0’-5-3/4” 14’-11-3/4” 19'-9 -1/4" X 16'-0 " PLYWOOD BACKIN G 5’-0” 3’-3/8” 1’-8” 1-7/8” 1 ’-1-5/8” L e tt er s t o be mou nted flush t o fa scia u sin g l ag bo l ts an d shields as required LED illumination Weep holes ¼" dia. exterior locations only Trim cap Aluminum backs 12 volt jacketed cable Lag Bolt & Shields Acrylic face Greenfield conduit ½" minimum Electronic power supply Power supply housing Primary electrical source STUD WALL CONCR E T E MASON R Y WALL Listed disconnectswitch LED CHANNEL - REMOTE, FLUSH - GENERIC INSTALL Aluminum returns Thru bolt - all thread fasteners w/ wood blocking or angle iron stringer Toggle bolts w/ hollow core- plywood backing Kwik Bolts or Expansion lag bolts & shields w/ solid concrete *MOUNTING METHOD: (Use appropriate method following wall inspection) 04/02/20 KW Updated size, mounting, and added plywood backing 251 E SH 114 Southlake, TX 76092 OPTION A 4’-6-1/2” 05/18/20 PS Added width of logo SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY:CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 5 Scale: 1/16”=1’-0”W E S T E LE V ATION PAGE NO. 02/21/20 C\L ±189 ’-6” ±19’-6 ” CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 5 PAGE NO. 04/02/20 ALL SIGN SIZES HAVE BEEN CALCULATED OFF ARCHITECTURAL PRINTS AS SHOWN 5 4 IN CH S T A C K E DA 5 9’-6 ” 2’-11”2’-11” 76’-6” 251 E SH 114 Southlake, TX 76092 OPTION B SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: Scale: 1/16”=1’-0”E A ST E L E V ATION CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 6 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 6 PAGE NO. 04/02/20 C\L ±189’-6 ”±26’-0” 6’-2”6’-2” 76’-6” 5 9’-6 ” ALL SIGN SIZES HAVE BEEN CALCULATED OFF ARCHITECTURAL PRINTS AS SHOWN 54 I NC H ST A C K EDB 251 E SH 114 Southlake, TX 76092 OPTION B SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: Scale: 3/16”=1’-0”FACE L I T CHAN NE L LE T T ER S 5 4 INC H ST AC K ED TYPICAL FRAMED WALL MOUNTING DETAIL 1/2” WALL SHEATHING 2X4 WOOD BLOCKING BETWEEN STUDS; ATTACH BLOCKING AT EACH END TO STUDS WALL STUD ON 16” CENTERS 3/8” DIA. THRU BOLT W/ NUT, FLAT & LOCK WASHERS typical 1/2” DIA SPACER FROM BACK OF LETTER TO FACE OF BLOCKING typical (2) TWO l e tterset s requ ire d for WES T AND E AST e levati onQUANTITY: FACES:3/16" #7328 whit e a cr ylic 3/16" #7328 whit e a cr ylic RETA INERS: T R IMCA P: 3/4" alum . r etainers - p aint ed black (’D’ l ogo o nly) 1” Black je wel i te (DELTA HOTELS, UN D E R SCORE, MARRIO TT) R E TURNS:5 ” d eep .080 alum . - in side s pre-painte d W hi te ; Outsides pa in ted Bla ck BA CKS: W ALL M ATERI AL: .0 6 3 Alu m. - pre-pa in ted W hi te Not provided at t hi s tim e ILLUM.:GE Wh it e LED as re q u i r ed by m anu fac turer ; Re mote Po wer sup p lies EAS T E L E VATION LET TERS ET ONLY Le t ters to be pr e-wired d ur ing a sp ecial t rip. "D" log o, se c ond ar y wire to be b ro ught out t h ro ugh t he bottom of the lo go so it can be acc essed from the guest room r ather than the r oof INSTALL: CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 7 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 7 PAGE NO. 04/02/20 A B 130.3 square feet L e tt er s t o be mou nted flush t o fa scia u sin g l ag bo l ts an d shields as required LED illumination Weep holes ¼" dia. exterior locations only Trim cap Aluminum backs 12 volt jacketed cable Lag Bolt & Shields Acrylic face Greenfield conduit ½" minimum Electronic power supply Power supply housing Primary electrical source STUD WALL CONCR E T E MASON R Y WALL Listed disconnectswitch LED CHANNEL - REMOTE, FLUSH - GENERIC INSTALL Aluminum returns Thru bolt - all thread fasteners w/ wood blocking or angle iron stringer Toggle bolts w/ hollow core- plywood backing Kwik Bolts or Expansion lag bolts & shields w/ solid concrete *MOUNTING METHOD: (Use appropriate method following wall inspection) 251 E SH 114 Southlake, TX 76092 OPTION B 130.3 sq ft 16’-9-3/4” 9’-5-1/8” 13’-5-7/8” 17'-9-3/4" X 14'-5-7/8" PLYWOOD BACKING 4’-6” 2’-8-7/8” 1’-6” 1-5/8 ” 1’-1/4” 4 ’-1” 05/18/20 PS Added width of logo SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: Scale: 1/16”=1’-0”NOR TH ELEVAT I ON CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 8 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 8 PAGE NO. 03/31/20 C\L ±266'-0 ” ±30’-6” ±7’-6” C 18 I NC H S T AC K ED 04/02/20 KW Added plywood backing 251 E SH 114 Southlake, TX 76092 SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: Scale: 1 /2”=1’-0” 39.2 square feet FACE L I T CHAN NE L LE T T ER S ELECTRICAL ACCESS TO BE CONFIRMED TO ENSURE REMOTE POWER SUPPLIES ARE POSSIBLE! ELECTRICAL TYPICAL FRAMED WALL MOUNTING DETAIL 1/2” WALL SHEATHING 2X4 WOOD BLOCKING BETWEEN STUDS; ATTACH BLOCKING AT EACH END TO STUDS WALL STUD ON 16” CENTERS 3/8” DIA. THRU BOLT W/ NUT, FLAT & LOCK WASHERS typical 1/2” DIA SPACER FROM BACK OF LETTER TO FACE OF BLOCKING typical (1 ) ON E let terset required for NOR TH eleva ti o nQUANTITY: FACES:3/16" #244 7 w hi te acr yl i c wit h su r f ace app l ied dua l co l or black vinyl ove r l ay s; To i lluminate whi te a t night TRI M CAP :1 ” B lac k jew elite RETUR N S:5” dee p .050 alu m. - ins ides pr e-pai nted Whit e; O utsid es p aint ed Bl ack BAC KS: WA LL MATERIA L: .063 Alum . - p r e-p aint ed Whit e Not p rovi d ed a t this time ILLUM.:G E White L ED as required by ma nufact ure r ; R emote Powe r supplies - TO BE CON FIRMED IN STALL:Let ters to b e mo unte d flush to f asc ia usi ng la g bolt s a nd s hie l d s as r equi red CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 9 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 9 PAGE NO. 03/31/20 18 I NC H S T AC K EDC 04/02/20 KW Updated size, mounting, and added plywood backing 5’-2-1/4” 7’-5” 5’-3-1/2” 1 '-6" 9 -7 /8” 1” 6 -7 /8” LED illumination Weep holes ¼" dia. exterior locations only Trim cap Aluminum backs 12 volt jacketed cable Lag Bolt & Shields Acrylic face Greenfield conduit ½" minimum Electronic power supply Power supply housing Primary electrical source STUD WALL CONCR E T E MASON R Y WALL Listed disconnectswitch LED CHANNEL - REMOTE, FLUSH - GENERIC INSTALL Aluminum returns Thru bolt - all thread fasteners w/ wood blocking or angle iron stringer Toggle bolts w/ hollow core- plywood backing Kwik Bolts or Expansion lag bolts & shields w/ solid concrete *MOUNTING METHOD: (Use appropriate method following wall inspection) 6 '-3-1/2" X 8'-5" PLYWOOD BACKI NG 251 E SH 114 Southlake, TX 76092 SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY:CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 1 0 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 1 0 PAGE NO. 04/21/20 251 E SH 114 Southlake, TX 76092 Scale: 3 /8”=1’-0”PR OP OSED MON UM EN T 6'-0" OAH 2'-6 " 6" ±2'-0" 25'-10 " 4" 1 1 I NC H L I N EA R T YP IC A L OF (2) LO CATIONS MAS O NRY BRICK MOCK UP Wall has a radius cur ve of 20'-10" D 2 5 1 6" SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: Scale: 3 /4”=1’-0” 15.78 square feet HALO LIT L ET TERSET CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 1 1 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 1 1 PAGE NO. 03/31/20 1 1 I NC H L I N EA R 11-3/8”11” 6” 17’-2-5/8” 6-7/8” 1 1’-2-3/8”5’-3 -5 /8” (2) Two letterse t s required; (1) One o f each side of entranceQUANTITY: G E White LED as r e qu ired by ma nufacturer ; Re mot e Power s upp l ies FACE S :.090 alum. pain ted Wh ite RE TURN S:3 ” deep .063 a lum. welded to faces - a ll we lds to be san ded smooth ; painted Bl ack BAC KS : A DDRES S : 1/4” Clea r polycarbon at e 1/2" flat acr yl ic cut outs, pai nted black; Let ters dri ll e d and tapped to accept studs for flush mount in g; All p e netrations f il led with si licone IL LU MIN ATION: INSTALL :1 -1/2” stand of f from rock wa ll sur f ac e ; Spa c e rs to be p r o vided p aint e d t o matc h bk gd.; Wall has a r adi us c ur ve of 2 0'-10" W hite D Le tters to b e p re-w ire d d u ring a sp ecial tri p 04/02/20 KW Added note about pre wiring 251 E SH 114 Southlake, TX 76092 M A SONRY BRICK MOCK UP 2 5 1 10 -1/2” SITE SURVEY REQUIRED JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: FOR REFERENCEACCENT L IG HTI NG L IGHTING TO B E H A NDL E D BY G C TYPICAL ACCE NT I L LUMINATIO N CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 1 2 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 1 2 PAGE NO. 04/21/20 251 E SH 114 Southlake, TX 76092 JAMES PEAKE / TIM FENSKE 584990 PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. CLIENT SIGNATURE: APPROVAL DATE:800.627.4460 440.209.6200 8959 Tyler Boulevard Mentor, O hio 44060 t heM Cgro u p.com REVISION HISTORY: FOR REFERENCESITE P LAN CLIENT: ADDRESS: 37529 GRAND RIVER AVENUE FARMINGTON HILLS, MI TICKET NO.: PROJECT MANAGER: EASEL 137164 DAVE HOLBROOK ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\MI\Delta Hotels_Farmington Hills KW DATE: DESIGNER: 1 3 PAGE NO. 02/21/20 CLIENT: ADDRESS: TICKET NO.: PROJECT MANAGER: ELECTRONIC FILE NAME: MARRIOT T\DELTA HOTEL\2020\TX\Delta Hotels_Southlake KW DATE: DESIGNER: 1 3 PAGE NO. 03/31/20 04/02/20 KW Updated sign location D 1 1 INC H L I N EA R 1 1 I NC H L I N E A R D D 1 8 IN C H S T AC K E DC A B 72 INC H ST AC K ED AC CE N T L IGH TI N G DON E BY OT H ER S 7 2 INC H ST AC K ED 251 E SH 114 Southlake, TX 76092 JAMES PEAKE / TIM FENSKE 584990