Item 8 - Preliminary Drainage Study
KIRKMAN ENGINEERING :: 5200 State Highway 121, Colleyville, TX 76034 Ph: 817-488-4960 :: TBPE Firm #15874
Page 1 of 4
Timberlake Office – Preliminary Drainage Study
City of Southlake, Tarrant County, Texas
January 31, 2020
Prepared for:
Department of Planning & Development Services
City of Southlake
1400 Main Street, Suite 310
Southlake, Texas 76092
Prepared by:
Kirkman Engineering
5200 State Highway 121
Colleyville, TX 76034
817.488.4960
KIRKMAN ENGINEERING :: 4821 Merlot Avenue, Suite 210, Grapevine, TX 76051 Ph: 817-488-4960 :: TBPE Firm #15874
Page 2 of 4
1.0 INTRODUCTION
The Timberlake Office is a proposed office building located along Southlake Blvd, approximately
0.25 miles east of Shady Oaks Dr. The office is proposed on a 0.859-acre site, which was
recently cleared of the residential structures.
The current effective FEMA Flood Insurance Rate Map (FIRM) for this area of Tarrant County,
panel 85, dated September 25, 2009, shows that the full extents of the property is located
within Zone X, which is an area determined to be outside the 0.2% annual chance floodplain.
The owner of this site is proposing to rezone the property for office use. The purpose of this
report is to analyze any drainage impacts that changing the use for this property would have
on-site or on adjacent properties.
Existing Residence
Zoned “AG”
KIRKMAN ENGINEERING :: 4821 Merlot Avenue, Suite 210, Grapevine, TX 76051 Ph: 817-488-4960 :: TBPE Firm #15874
Page 3 of 4
2.0 HYDRAULICS
Kirkman Engineering has completed a drainage analysis for the existing site to determine the total runoff
currently being discharged to adjacent properties along with a post-developed drainage analysis to
determine the storm water effects of the site development. The rational method was used to compute
the total runoff values. The runoff coefficients are based on the City of Southlake drainage criteria, and
the time of concentration calculations are based on the iSWM Technical Manual: Hydrology.
2.1 EXISTING CONDITIONS HYDRAULICS
The site has been cleared of the existing improvements within the property boundary. There are
currently no drainage structures on-site and the existing topography directs flows universally away from
the original residence on the property. The land is currently zoned AG. The existing use of the property
was single family residential, therefore a runoff coefficient of 0.51 was used per the City of Southlake’s
drainage criteria. Using the rational method, this results in a total runoff value of 4.05 cfs. The runoff
discharges directly to adjacent properties to the south and east.
2.2 PROPOSED CONDITIONS HYDRAULICS
The purpose of this rezoning is to allow for office us. Per the proposed improvements associated with
this development, the total runoff from the overall site will increase to 6.99 cfs.
However, the proposed flow draining to the adjacent properties will decrease from existing conditions
due to the site is being designed to allow for most of the discharge to flow north to FM 1709. Once
developed, the amount of flow from this site to the residential property to the south and east will be
reduced to 0.45 cfs.
The remainder of the on-site flow will drain to the north and onto FM 1709, and ultimately to an existing
curb inlet to the west. This inlet and associated storm pipe were designed to accept our on-site
developed flow. Per the TxDOT drainage infrastructure plans, the design flow for this existing inlet is 9.6
cfs and the pipe capacity is 38.4 cfs. After development of our site, the total flow draining to the existing
inlet will be 8.65 cfs, which is less than the design flow.
Existing Residence 0.86 0.51 0.44 10.0 6.01 2.63 9.24 4.05 Drains to Adjacent Properties
Q5
(c.f.s.)
I100
(in./hr.)
Q100
(c.f.s.)Acres CA Drainage Area Runoff
Coeff.
Tc
(min.)
DRAINAGE AREA CALCULATIONS (EXISTING)
CommentsI5
(in./hr.)
Proposed Office 0.86 0.88 0.76 10.0 6.01 4.54 9.24 6.99 Total Developed Flow
Q100
(c.f.s.)Comments
DRAINAGE AREA CALCULATIONS (PROPOSED)
Drainage Area Acres Runoff
Coeff.CA Tc
(min.)
I5
(in./hr.)
Q5
(c.f.s.)
I100
(in./hr.)
KIRKMAN ENGINEERING :: 4821 Merlot Avenue, Suite 210, Grapevine, TX 76051 Ph: 817-488-4960 :: TBPE Firm #15874
Page 4 of 4
3.0 CONCLUSION
This report includes preliminary drainage computations pertaining to the existing conditions and
proposed conditions for the Timberlake Office Zoning case. The post-development flow will see an
increase in runoff, but this increase flow will be redirected to the north and into the existing TxDOT
drainage system. Once developed, the flow to the adjacent properties will be reduced from existing
conditions.
A more detailed study of the site, along with the downstream components of the existing drainage
infrastructure will be completed during the full civil design phase of the project.