SB Item 6 - Sign packageHAVERTYS FURNITURE
LEASE EXHIBIT
250 N KIMBALL AVE, SOUTHLAKE, TX 76092
11/22/19
SITE PLAN EXHIBIT
EXISTING PARKING SPACESHAVERTYS FURNITURE
LOADING
DOCK/
SERVICE
AREA
EXISTING
ADJACENT BUILDING
Landlord Document Review
_____ Concept Approved As Noted
_____ Not Approved - Revise & Resubmit
FINISH OUT
•The concept approval granted herewith is for design intent only
as granted in the REA. No approval or disapproval of
architectural, structural, mechanical, electrical and plumbing is
implied or given by this review. Said approval does not change
the terms or rights of the REA.
•Professional Design consultants whose seals appear on these
drawings, Tenants and their contractors are fully responsible for
compliance with all Federal, State, and Local Codes &
Ordinances as well as compliance with Lease Agreements for
this project.
•All work must be free of hazardous materials of any kind.
•If there is a discrepancy between the plans and the Lease, the
Lease shall prevail.
•Any changes to these plans, after said approval, requires a
re-submittal to Landlord for review and approval.
•GC shall obtain the list of Landlord's required vendors and
Rules & Regulations for the specific center from Landlord's
Representatives and shall comply to those requirements.
•Signage review is a deferred submittal to be handled separately
and is NOT included in this plans review/approval.
•Provide Landlord with a copy of the as-built or City approved
plans with Architect’s and Engineers’ signature and seal, in pdf
format, as well as a CAD file of the floor plan (only) to Landlord
at the end of the project.
•Provide a copy of the City approved permit plans to Landlord at
the end of the build out.
_____ Concept Approved As Noted
_____ Not Approved - Revise & Resubmit
SIGNAGE
•The concept approval granted herewith is for design intent only.
•Tenants and their contractors are fully responsible for
compliance with all Federal, State, Local Codes & Ordinances,
and the Design Review Board (Association) as well as
compliance with Lease Agreements for this project.
•All work must be free of hazardous materials of any kind.
•If there is a discrepancy between the plans and the Lease, the
Lease shall prevail.
•It is Tenant's responsibility to remove existing signage (if
applicable), patch, repair and repaint the sign facade area to
like-new condition.
•UL labels shall not be visible to the public view. Termination of
electrical service shall be hidden from public view.
•Contact the Center's Property Manager to arrange for
installation of signage, which should not interfere with Center’s
open and operating tenants.
•Mounting - all penetrations to be in mortar joints ONLY and
NOT Through the brick and sealed water-tight.
•Display of banners, flags, pennants, streamers, balloons, and
inflatables are not allowed unless granted per Lease agreement
or written authorization from Landlord.
•If you do not have any rights to the Center's monument and/or
pylon sign, per the Lease, you will need to request permission
from your Center's Property Manager.
By: ______________________________________
Brant Mullen, Sr. Tenant Coordinator Date
972-801-6008 or mullen@rpai.com Ops_______
12/17/19
12/17
Landlord Document Review
_____ Concept Approved As Noted
_____ Not Approved - Revise & Resubmit
FINISH OUT
•The concept approval granted herewith is for design intent only
as granted in the REA. No approval or disapproval of
architectural, structural, mechanical, electrical and plumbing is
implied or given by this review. Said approval does not change
the terms or rights of the REA.
•Professional Design consultants whose seals appear on these
drawings, Tenants and their contractors are fully responsible for
compliance with all Federal, State, and Local Codes &
Ordinances as well as compliance with Lease Agreements for
this project.
•All work must be free of hazardous materials of any kind.
•If there is a discrepancy between the plans and the Lease, the
Lease shall prevail.
•Any changes to these plans, after said approval, requires a
re-submittal to Landlord for review and approval.
•GC shall obtain the list of Landlord's required vendors and
Rules & Regulations for the specific center from Landlord's
Representatives and shall comply to those requirements.
•Signage review is a deferred submittal to be handled separately
and is NOT included in this plans review/approval.
•Provide Landlord with a copy of the as-built or City approved
plans with Architect’s and Engineers’ signature and seal, in pdf
format, as well as a CAD file of the floor plan (only) to Landlord
at the end of the project.
•Provide a copy of the City approved permit plans to Landlord at
the end of the build out.
_____ Concept Approved As Noted
_____ Not Approved - Revise & Resubmit
SIGNAGE
•The concept approval granted herewith is for design intent only.
•Tenants and their contractors are fully responsible for
compliance with all Federal, State, Local Codes & Ordinances,
and the Design Review Board (Association) as well as
compliance with Lease Agreements for this project.
•All work must be free of hazardous materials of any kind.
•If there is a discrepancy between the plans and the Lease, the
Lease shall prevail.
•It is Tenant's responsibility to remove existing signage (if
applicable), patch, repair and repaint the sign facade area to
like-new condition.
•UL labels shall not be visible to the public view. Termination of
electrical service shall be hidden from public view.
•Contact the Center's Property Manager to arrange for
installation of signage, which should not interfere with Center’s
open and operating tenants.
•Mounting - all penetrations to be in mortar joints ONLY and
NOT Through the brick and sealed water-tight.
•Display of banners, flags, pennants, streamers, balloons, and
inflatables are not allowed unless granted per Lease agreement
or written authorization from Landlord.
•If you do not have any rights to the Center's monument and/or
pylon sign, per the Lease, you will need to request permission
from your Center's Property Manager.
By: ______________________________________
Brant Mullen, Sr. Tenant Coordinator Date
972-801-6008 or mullen@rpai.com Ops_______
1/21/2020
12/17
See "Elevations Exhibit," 3rd sheet for LL general signage requirements for all signs.
1/29/2020
NOTES FOR ALL BUILDING SIGNS:
•PENETRATIONS TO BE WITHIN MORTAR
JOINTS AS MUCH AS FEASIBLY POSSIBLE,
sign company to site survey pylon and submit
template to LL for approval, showing
brick/mortar pattern and placement of
mounting hardware prior to fabrication
•Tenant and sign company are responsible for
cleaning the façade, windows, sidewalks,
awnings/canopies of any residue/debris from
installation and repairing any damage to
premises
•Installation to occur before or after business
hours, coordinate with property management
for specific times, and shall not block any drive
aisles. Southlake signage installation shall be
supervised by LL Team to ensure correct
placement and specs of signage, schedule
with LL Team (typically between 8 and 10 am).
•Center sign vertically in sign band (between
opening below & coping elements above) and
horizontally over window storefront/wall
bay/architectural elements (or lease lines, very
dependent on building/architecture).
•No visible electrical equipment or structural
elements allowed, including but not limited to:
conduit, transformers, wiring, angles, bolts,
brackets, angle iron, Unistrut, etc. (incl. on roof
or rear of parapet)
•Core drilling is to be from the exterior to the
interior to prevent spalling
•Utilize existing penetrations where possible
•Minimize number and size of penetrations in
wall
•Seal all, old and new, penetrations in walls
and paint to match
•Utilize and conceal non-corrosive mounting
hardware/fasteners
•Any stickers, U.L labels, etc. are not to be
visible from ground
•Tenant is responsible for removing signage,
cleaning facade, and patching all penetrations
to match existing façade/mortar/brick colors,
texture(s), materials, conditions, etc. to
like-new condition.
•When patching/repairing facade, Tenant is
responsible for painting seam to seam, to keep
facade colors consistent and in a first-class
state.
•Tenant may be required to remove and
replace signage if not installed per LL’s
approval
•Tenant to provide adequate blocking behind
any EIFS to provide structural stability for all
signage and exterior modifications
•Any disconnect switch to be attached to sign
/ letters in as concealed location as possible
•Remove all existing j-boxes, conduit, etc.
remaining from previous tenant
•Halo lit standoffs to be painted to match
building color and electrical wiring to be in
conduit (not exposed to the elements)
•Mount below roof deck (preferred), if not
possible, do not penetrate roof
membrane/flashing and seal penetrations on
both sides
oUtilize LL required roofer to seal electrical
service penetration/s (via pitch
pan/weatherhead)
oWiring to be in conduit and organized in a
clean manner
oPaint all to match parapet color
1st
HAVERTYS FURNITURE
LEASE EXHIBIT
250 N KIMBALL AVE, SOUTHLAKE, TX 76092
11/22/19
LIGHT COVE SPECIFICATION
GRAZING LIGHT FIXTURE SPECIFICATION
08/05/19
HAVERTYS FURNITURE
1100 SEABOARD ST, MYRTLE BEACH, SC 29577
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/21/2020
See "Elevations Exhibit," 3rd sheet for LL general signage requirements for all signs.1st
HAVERTYS FURNITURE
LEASE EXHIBIT
250 N KIMBALL AVE, SOUTHLAKE, TX 76092
11/22/19
WALL SCONCES SPECIFICATION
08/05/19
HAVERTYS FURNITURE
1100 SEABOARD ST, MYRTLE BEACH, SC 29577
WALL SCONCES SPECIFICATION
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/21/2020
See "Elevations Exhibit," 3rd sheet for LL general signage requirements for all signs.1st
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
1
nts
AERIAL VIEW
STANDARD STORE HOURS VINYL | ONE (1) REQ’D
(RFLCH-HF-4214-B-LED) FACE & BACK-LIT CHANNEL LETTER | ONE (1) REQ’D
VINYL ADDRESS NUMERALS - FRONT ENTRANCE | ONE (1) REQ’D
HANDICAP PARKING SIGNS | THREE (3) REQ’D
CHANNEL LETTER SETS FOR MULTI-TENANT SIGNS | TWO (2) SETS
CHANNEL LETTER SETS FOR MULTI-TENANT SIGNS | FOUR (4) SETS
S I G N L E G E N D E X T E R I O R S I G N
S I G N L E G E N D I N T E R I O R S I G N
A
B
C
G
F1
F4
F2
F5F3 F6
(RFLCH-H-42-B-LED ) FACE & BACK-LIT CHANNEL LETTER | TWO (2) REQ’D
CUSTOM VINYL GRAPHICS FOR ENTRY DOOR GLASS | TWO (2) REQ’D
D
E
V-EER-01 RED EMERGENCY DOOR VINYLH
V-EEW-01 WHITE EMERGENCY DOOR VINYLI
ADA-R-W01-G WOMEN'S ADA PLAQUEJ
ADA-R-M02-G MEN'S ADA PLAQUE K
ADA-APO-01-G AUTHORIZED PERSONNEL ONLY PLAQUE L
ADA-ER-02-G ELECTRICAL ROOM PLAQUE M
ADA-FACP-G FACP ROOM PLAQUE N
ADA-SRR-G SPRINKLER RISER ROOM PLAQUE O
CPU-WB-01-B CUSTOMER PICK-UP CALL BUTTON SIGN P
GUEST SERVICES LETTERSETQ
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
| ONE (1) SET REQ’D
A
C
D
E
G
F1
F3
F6
F2
F4
F5
B2
B1
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/29/2020
See 1st sheet for LL general signage requirements for all signs.
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
2
FRONT ELEVATION - DAY LOOK
FRONT ELEVATION - NIGHT LOOK
37
'
-
7
"
178'-11"
25'-6"
45'-2"
3'
-
6
"
5'-7 1/2"
EQ
EQ
EQ
A
CD E
10
'
-
1
0
"
SEE PAGE 9 FOR ENLARGED VIEWSCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
37
'
-
7
"
EQ
23'-5"16'-7"23'-5"
15'-5"
28'-10"
10'-9"
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/21/2020
See 1st sheet for LL general signage requirements for all signs.
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
3
SIDE ELEVATION - DAY LOOK
SIDE ELEVATION - NIGHT LOOK
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
3'
-
6
"
EQ
B1
25'-6"EQ EQ
EQ
37
'
-
0
"
6'-4"
15'-9"
12’-9”
37
'
-
0
"
31'-0"
224'-6"
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/21/2020
See 1st sheet for LL general signage requirements for all signs.
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
4
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
REAR ELEVATION - DAY LOOK
REAR ELEVATION - NIGHT LOOK
178'-10"
25'-6"
3'
-
6
"
EQ
EQ
EQ EQ
B2
37
'
-
0
"
37
'
-
0
"
29’-0”
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/21/2020
See 1st sheet for LL general signage requirements for all signs.
October 16, 2019
23-58475-10 R4c
23-58475-10
Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
5
A
B
C
D
E
Min Sq.Ft Max Sq. Ft Total AmpsSign Type
42"25'-6"14 1/2" 17'-7"67 1/2"110.5 143.44 T.B.D.
INDIVIDUAL INTERNALLY ILLUMINATED FACE & BACK-LIT CHANNEL LETTER LAYOUT- L.E.D. | ONE (1) REQ’D
FACE: 3/16" TRANSLUCENT WHITE ACRYLIC WITH VINYL APPLIED FIRST SURFACE
BACK: 1/4" THICK CLEAR LEXAN BACK
RETURNS: .063" MINIMUM ALUMINUM RETURNS PAINTED BLUE
TRIMCAP: BLUE T/M RETURNS PMS 281C
ILLUMINATION: WHITE L.E.D. LIGHTING - NUMBER/ TYPE/ LOCATION OF L.E.D.’S AS REQUIRED TO PROVIDE
PROPER LIGHTING.
FEDERAL HEATH MANUFACTURING TO PROVIDE & INSTALL 3/8" CAPTIVATED NUTS FOR LETTER SETS.
MATERIAL COLOR SPECS
3M 3630-36 (VINYL)
PMS 281 C
WHITE
ACRYLIC
RFLCH-HF-4214-B-LED
NOTE: ALL MOUNTING HARDWARE IS THE RESPONSIBILITY
OF INSTALL CONTRACTOR, EXCEPT CLIPS.
SECTION DETAIL - L.E.D. FACE LIT/HALO WALL LETTERS
Electrical To Power Supply In
Flexible Conduit (by Installer)
J-Box And Final Hook-up
By G.C. Electrician. (120v-20 amp circuit)
Metal Pass-Thru In Wall For Supply Leads
LED LOW VOLTAGE LIGHTING SYSTEM
U.L. LISTED CLASS 2 - CONFORMS TO U.L. 48 and NEC 600 CODE
Wood Blocking Required For EIFS Walls
(Provided by Customer if Needed)
1 ½”
¼” Drain
Hole
Non-Corrosive
Type Mounting
Hardware
(Three Min. Per Letter)
3/16" Acrylic Faces
LED Light Modules-
Mfg to determine best type
of LED’s & location.
Clear Poly Back w/
Frosted Vinyl Diffuser
Trim Cap Retainer
Aluminum Letter Returns
with White Interior Finish
½" Round Spacers
(All Penetrations to be Sealed w/ Silicone)
120 VAC Electronic Power Supply
(12VDC - Mount In Dry Area Only)
14 AWL Wire From Power Supply
To LED Connector Inside
Each Letter.
Booted Toggle Switch on Box
22 Ga Metal Transformer Box
PVC Spacers Required for EIFS Wall Material
(Provided by Installer)l
5"
N.T.S.
INSTALLATION OF THIS SIGN SHALL CONFORM
TO ARTICLE 600 OF THE NEC, UL 48 AND OR
OTHER APPLICABLE LOCAL CODES, INCLUDING
THE PROPER GROUNDING AND BONDING OF THE SIGN.
THE LOCATION OF THE DISCONNECT SWITCH, AFTER INSTALLATION
SHALL COMPLY WITH ARTICLE 600.6(A) OF THE NEC.
A
NOTE: ACCESS, BLOCKING, AND ELECTRICAL ARE THE RESPONSIBILITY OF THE GC
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/21/2020
See "Elevations Exhibit," 3rd sheet for LL general signage requirements for all signs.1st
October 16, 2019
23-58475-10 R4c
23-58475-10
Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
6
A
B
INDIVIDUAL INTERNALLY ILLUMINATED FACE & BACK-LIT CHANNEL LETTER LAYOUT - L.E.D. | TWO (2) REQ.
FACE: 3/16" TRANSLUCENT WHITE ACRYLIC WITH VINYL APPLIED FIRST SURFACE
BACK: 1/4" THICK CLEAR LEXAN BACK
RETURNS: .063" MINIMUM ALUMINUM RETURNS PAINTED BLUE
TRIMCAP: BLUE T/M RETURNS PMS 281C
FEDERAL HEATH MANUFACTURING TO PROVIDE & INSTALL 3/8" CAPTIVATED NUTS FOR LETTER SETS.
SQ. FT Total AmpsSign Type
42"25'-6"T.B.D.RFLCH-H-42-B - LED 89.25
MATERIAL COLOR SPECS
3M 3630-36 (VINYL)
PMS 281 C
WHITE
ACRYLIC
NOTE: ALL MOUNTING HARDWARE IS THE RESPONSIBILITY
OF INSTALL CONTRACTOR, EXCEPT CLIPS.
SECTION DETAIL - L.E.D. FACE LIT/HALO WALL LETTERS
Electrical To Power Supply In
Flexible Conduit (by Installer)
J-Box And Final Hook-up
By G.C. Electrician. (120v-20 amp circuit)
Metal Pass-Thru In Wall For Supply Leads
LED LOW VOLTAGE LIGHTING SYSTEM
U.L. LISTED CLASS 2 - CONFORMS TO U.L. 48 and NEC 600 CODE
Wood Blocking Required For EIFS Walls
(Provided by Customer if Needed)
1 ½”
¼” Drain
Hole
Non-Corrosive
Type Mounting
Hardware
(Three Min. Per Letter)
3/16" Acrylic Faces
LED Light Modules-
Mfg to determine best type
of LED’s & location.
Clear Poly Back w/
Frosted Vinyl Diffuser
Trim Cap Retainer
Aluminum Letter Returns
with White Interior Finish
½" Round Spacers
(All Penetrations to be Sealed w/ Silicone)
120 VAC Electronic Power Supply
(12VDC - Mount In Dry Area Only)
14 AWL Wire From Power Supply
To LED Connector Inside
Each Letter.
Booted Toggle Switch on Box
22 Ga Metal Transformer Box
PVC Spacers Required for EIFS Wall Material
(Provided by Installer)l
5"
ILLUMINATION: WHITE L.E.D. LIGHTING - NUMBER/ TYPE/ LOCATION OF L.E.D.’S AS REQUIRED TO PROVIDE
PROPER LIGHTING.
N.T.S.
INSTALLATION OF THIS SIGN SHALL CONFORM
TO ARTICLE 600 OF THE NEC, UL 48 AND OR
OTHER APPLICABLE LOCAL CODES, INCLUDING
THE PROPER GROUNDING AND BONDING OF THE SIGN.
THE LOCATION OF THE DISCONNECT SWITCH, AFTER INSTALLATION
SHALL COMPLY WITH ARTICLE 600.6(A) OF THE NEC.
B
NOTE: ACCESS, BLOCKING, AND ELECTRICAL ARE THE RESPONSIBILITY OF THE GC
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/21/2020
See "Elevations Exhibit," 3rd sheet for LL general signage requirements for all signs.1st
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
10
EXISTING PROPOSED (OPPOSITE SIDE SIMILAR) PROPOSED - NIGHT VIEW
F1
F2
EXISTING PROPOSED (OPPOSITE SIDE SIMILAR) PROPOSED - NIGHT VIEW
5’-0”
7’-2”
7’-2”
4’-3”
6’-8”
10’-0”
F3 F3
F3
F4
6’-8”
F1
10’-9”
10’-3”
35” Deep
9’-2”
10’-0”
10’-9”
8’-0”6’-7”
34” Deep
F1
OPPOSITE SIDE
NOT SHOWN
OPPOSITE SIDE
NOT SHOWN
LANDLORD INFORMED THAT INTERIOR OF MONUMENT SIGNS ARE ACCESSIBLE FOR POWER & WIRING.
15 1/8"
11 1/8"
PENETRATIONS TO BE
WITHIN MORTAR JOINTS AS
MUCH AS FEASIBLY
POSSIBLE, sign company to
site survey façade and submit
template to LL for approval,
showing brick/mortar pattern
and placement of mounting
hardware prior to fabrication
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/29/2020
See 1st sheet for LL general signage requirements for all signs.
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
11
PROPOSED - OPPOSITE SIDE PROPOSED - NIGHT VIEW
F5 F5
F6 F6
6’-8”
6’-8”
7’-2”
7’-2”7’-2”
EXISTING PROPOSED PROPOSED - NIGHT VIEW
4’-3”
6’-8”
10’-0”
5’-0”
7’-2”
35” Deep
F5
EXISTING
F6
OPPOSITE SIDE
LANDLORD INFORMED THAT INTERIOR OF MONUMENT SIGNS ARE ACCESSIBLE FOR POWER & WIRING.
11 1/8"
11 1/8"
PENETRATIONS TO BE
WITHIN MORTAR JOINTS AS
MUCH AS FEASIBLY
POSSIBLE, sign company to
site survey façade and submit
template to LL for approval,
showing brick/mortar pattern
and placement of mounting
hardware prior to fabrication
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/29/2020
See 1st sheet for LL general signage requirements for all signs.
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
12
INDIVIDUAL INTERNALLY ILLUMINATED FACE & BACK-LIT CHANNEL LETTER LAYOUT- L.E.D. | TWO (2) REQ’D
FACE: 3/16" TRANSLUCENT WHITE ACRYLIC WITH VINYL APPLIED FIRST SURFACE
BACK: 1/4" THICK CLEAR LEXAN BACK
RETURNS: .063" MINIMUM ALUMINUM RETURNS PAINTED BLUE
TRIMCAP: BLUE T/M RETURNS PMS 281C
ILLUMINATION: WHITE L.E.D. LIGHTING - NUMBER/ TYPE/ LOCATION OF L.E.D.’S AS REQUIRED TO PROVIDE
PROPER LIGHTING.
FEDERAL HEATH MANUFACTURING TO PROVIDE & INSTALL 3/8" CAPTIVATED NUTS FOR LETTER SETS.
MATERIAL COLOR SPECS
3M 3630-36 (VINYL)
PMS 281 C
WHITE
ACRYLIC
NOTE: ALL MOUNTING HARDWARE IS THE RESPONSIBILITY
OF INSTALL CONTRACTOR, EXCEPT CLIPS.
SECTION DETAIL - L.E.D. FACE LIT/HALO WALL LETTERS
Electrical To Power Supply In
Flexible Conduit (by Installer)
J-Box And Final Hook-up
By G.C. Electrician. (120v-20 amp circuit)
Metal Pass-Thru In Wall For Supply Leads
LED LOW VOLTAGE LIGHTING SYSTEM
U.L. LISTED CLASS 2 - CONFORMS TO U.L. 48 and NEC 600 CODE
Wood Blocking Required For EIFS Walls
(Provided by Customer if Needed)
1 ½”
¼” Drain
Hole
Non-Corrosive
Type Mounting
Hardware
(Three Min. Per Letter)
3/16" Acrylic Faces
LED Light Modules-
Mfg to determine best type
of LED’s & location.
Clear Poly Back w/
Frosted Vinyl Diffuser
Trim Cap Retainer
Aluminum Letter Returns
with White Interior Finish
½" Round Spacers
(All Penetrations to be Sealed w/ Silicone)
120 VAC Electronic Power Supply
(12VDC - Mount In Dry Area Only)
14 AWL Wire From Power Supply
To LED Connector Inside
Each Letter.
Booted Toggle Switch on Box
22 Ga Metal Transformer Box
PVC Spacers Required for EIFS Wall Material
(Provided by Installer)l
5"
N.T.S.
F2F1
10’-3”
1’
-
5
1
/
8
”
1/2” = 1’-0”
LANDLORD INFORMED THAT INTERIOR OF MONUMENT SIGNS ARE ACCESSIBLE FOR POWER & WIRING.
PENETRATIONS TO BE WITHIN MORTAR
JOINTS AS MUCH AS FEASIBLY POSSIBLE, sign
company to site survey façade and submit template
to LL for approval, showing brick/mortar pattern and
placement of mounting hardware prior to fabrication
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/29/2020
See 1st sheet for LL general signage requirements for all signs.
October 16, 2019
23-58475-10 R5
23-58475-10 Matt Smith
Sharna Wilson
Jesthan Delcano/CHC
19250 N. KIMBALL AVE
SOUTHLAKE, TX 76092
Store #TBD
R1 12.23.19 CHC Insert night time elevation views, add raceway
to monument sign.
R2 12.23.19 CHC Inset 2nd monument location
R3 12.26.19 CHC Add 3rd monument location
R4 1.19.20 MG Update bldg, mon dim’s/ replace mon photos.
R4c 1.20.20 MG Chg labeling on Signs “F” (tenant signs).
R5 1.27.20 JDR Update Sign F1-F6. Update stucco measurements
13
INDIVIDUAL INTERNALLY ILLUMINATED FACE & BACK-LIT CHANNEL LETTER LAYOUT- L.E.D. | FOUR (4) REQ’D
FACE: 3/16" TRANSLUCENT WHITE ACRYLIC WITH VINYL APPLIED FIRST SURFACE
BACK: 1/4" THICK CLEAR LEXAN BACK
RETURNS: .063" MINIMUM ALUMINUM RETURNS PAINTED BLUE
TRIMCAP: BLUE T/M RETURNS PMS 281C
ILLUMINATION: WHITE L.E.D. LIGHTING - NUMBER/ TYPE/ LOCATION OF L.E.D.’S AS REQUIRED TO PROVIDE
PROPER LIGHTING.
FEDERAL HEATH MANUFACTURING TO PROVIDE & INSTALL 3/8" CAPTIVATED NUTS FOR LETTER SETS.
MATERIAL COLOR SPECS
3M 3630-36 (VINYL)
PMS 281 C
WHITE
ACRYLIC
1” = 1’-0”
6’-8”
11
1
/
8
”
F4F3
F6F5
NOTE: ALL MOUNTING HARDWARE IS THE RESPONSIBILITY
OF INSTALL CONTRACTOR, EXCEPT CLIPS.
SECTION DETAIL - L.E.D. FACE LIT/HALO WALL LETTERS
Electrical To Power Supply In
Flexible Conduit (by Installer)
J-Box And Final Hook-up
By G.C. Electrician. (120v-20 amp circuit)
Metal Pass-Thru In Wall For Supply Leads
LED LOW VOLTAGE LIGHTING SYSTEM
U.L. LISTED CLASS 2 - CONFORMS TO U.L. 48 and NEC 600 CODE
Wood Blocking Required For EIFS Walls
(Provided by Customer if Needed)
1 ½”
¼” Drain
Hole
Non-Corrosive
Type Mounting
Hardware
(Three Min. Per Letter)
3/16" Acrylic Faces
LED Light Modules-
Mfg to determine best type
of LED’s & location.
Clear Poly Back w/
Frosted Vinyl Diffuser
Trim Cap Retainer
Aluminum Letter Returns
with White Interior Finish
½" Round Spacers
(All Penetrations to be Sealed w/ Silicone)
120 VAC Electronic Power Supply
(12VDC - Mount In Dry Area Only)
14 AWL Wire From Power Supply
To LED Connector Inside
Each Letter.
Booted Toggle Switch on Box
22 Ga Metal Transformer Box
PVC Spacers Required for EIFS Wall Material
(Provided by Installer)l
5"
N.T.S.
LANDLORD INFORMED THAT INTERIOR OF MONUMENT SIGNS ARE ACCESSIBLE FOR POWER & WIRING.
PENETRATIONS TO BE WITHIN MORTAR
JOINTS AS MUCH AS FEASIBLY POSSIBLE, sign
company to site survey façade and submit template
to LL for approval, showing brick/mortar pattern and
placement of mounting hardware prior to fabrication
_____ Approved as Noted (AAN)
___________________________
Brant Mullen Date
1/29/2020
See 1st sheet for LL general signage requirements for all signs.