Loading...
Item 8 - PlansDATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE REVISIONS PROJECT: ADDRESS: C.D. PEEBLES SOLAR PV SYSTEM 1604 DEVON COURT SOUTHLAKE, TX 76092 COVER PAGE PV 100 Fi l e : 1 0 0 C O V E R P A G E P l o t t e d : 1 1 / 1 1 / 2 0 1 9 C O P Y R I G H T © 2 0 1 9 A X I U M S O L A R , I N C . T h i s d o c u m e n t , t h e i d e a s a n d d e s i g n s i n c o r p o r a t e d he r e i n a r e a n d s h a l l r e m a i n t h e P r o p e r t y o f A x i u m S o l a r , I n c . u n l e s s o t h e r w i s e s p e c i f i e d b y w r i t t e n c o n t r a c t . Th e s e d o c u m e n t s a r e n o t t o b e u s e d o r a l t e r e d , i n w h o l e o r i n p a r t , f o r o t h e r t h a n t h e o r i g i n a l i n t e n d e d u s e . Owner: C.D. Peebles 1604 Devon Court Southlake, TX 76092 Axium Solar: 1005 Placid Ave. STE 100 Plano, TX 75074 O: 972-633-8680 Andrew Whitehead Business Development Manager andrewwhitehead@axiumsolar.com Charles Wright, BSEE Project Engineer charleswright@axiumsolar.com Solar PV System Location Solar PV System CONSTRUCTION Project Description Installation of a rooftop solar array on the West and South facing rooftops. SolarEdge inverter mounted on interior garage wall of house, SE optimizers mounted under each module to comply with rapid shutdown requirements and utility disconnect mounted on the South exterior wall of house, near meter. Applicable Building Code Compliance 2017 National Electric Code (including 690.12, rapid shutdown) 2018 IRC / IBC 2018 IFC (1204) Drawing Index PV 100 Cover Page PV 101 Site Layout PV 102 One Line Electrical PV 103 Attachment Detail PV 104 Labels TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 300W MODULES (1) SOLAREDGE 7.6KW INVERTER(S) SNAPNRACK SERIES 100 RACKING 40° & ----° TILT(S) 275° & 185° ORIENTATION(S) Utility Meter, ESI ID# ? (855) 633-8680 (972) 633-8680 WWW.AXIUMSOLAR.COM 1005 PLACID AVE. SUITE 100 PLANO, TX 75074 11-11-2019; ELECTRICAL ONLY ( 8 ' 9LVLEOH/RFNDEOH /DEHOHG$&'LVFRQQHFW /RFDWHGZLQ RIPHWHU , 6RODU0RGXOHV (M/N: TSM-300DD05A.05) DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE 1/16" = 1'-0" REVISIONS PROJECT: ADDRESS: C.D. PEEBLES SOLAR PV SYSTEM 1604 DEVON COURT SOUTHLAKE, TX 76092 SITE LAYOUT PV 101 Fi l e : 1 0 1 S I T E L A Y O U T P l o t t e d : 1 1 / 1 1 / 2 0 1 9 C O P Y R I G H T © 2 0 1 9 A X I U M S O L A R , I N C . T h i s d o c u m e n t , t h e i d e a s a n d d e s i g n s i n c o r p o r a t e d h e r e i n a r e a n d s h a l l r e m a i n t h e P r o p e r t y o f A x i u m S o l a r , I n c . u n l e s s o t h e r w i s e s p e c i f i e d b y w r i t t e n c o n t r a c t . Th e s e d o c u m e n t s a r e n o t t o b e u s e d o r a l t e r e d , i n w h o l e o r i n p a r t , f o r o t h e r t h a n t h e o r i g i n a l i n t e n d e d u s e . CONSTRUCTION 8 ( ' 8WLOLW\0HWHU 0DLQ(OHFWULFDO3DQHO 39$&'LVFRQQHFW 6,7(3/$11HLJKERULQJ3URSHUW\ 'ULYHZD\ - 'H Y R Q  & R X U W ,39,QYHUWHUPQ6(+86 Notes: 1) No equipment will extend beyond the limits of existing building footprint. No property setbacks will be encroached upon. 2) Solar modules to be mounted to existing roof structure. 3) Exact layout to be adjusted as required to avoid roof and plumbing vents. 4) Locate solar AC disconnect within 10 feet of utility meter. 5) Installation to comply with the requirements of Section 1204 of IFC 2018. 6) Coordinate with homeowner for all equipment and conduit placements. 1RVKRZQLQPRGXOHLQGLFDWHVVWULQJ 3URSHUW\/LQH *DUDJH 6LQJOHPRGXOHZLGWKLV TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 300W MODULES (1) SOLAREDGE 7.6KW INVERTER(S) SNAPNRACK SERIES 100 RACKING 40° & ----° TILT(S) 275° & 185° ORIENTATION(S) Utility Meter, ESI ID# ?   (855) 633-8680 (972) 633-8680 WWW.AXIUMSOLAR.COM 1005 PLACID AVE. SUITE 100 PLANO, TX 75074 &RYHQWU\/DQH                         11-11-2019; ELECTRICAL ONLY UTILITY METER SERVICE ENTRANCE EQUIPMENT LOCATION NOTES [Existing] 200 A 240/120 VAC Utility Meter ESI ID# ? $&*URXQGLQJ (OHFWURGH6\VWHP SHEET NOTES: 1. THE INSTALLATION OF THIS SOLAR PV SYSTEM SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE (NEC). 2. DERATE CONDUCTORS FOR ACTUAL INSTALLATION CONDITIONS. 3. ALL DISTANCES SHOWN ARE ESTIMATES ONLY. ACTUAL DISTANCES WILL VARY AND SHALL BE VERIFIED ON SITE. 4. CONDUIT, WHERE INSTALLED, SHALL BE AS FOLLOWS: 4.1. ABOVEGROUND - EMT W/ ALL-STEEL COMPRESSION TYPE FITTINGS. 4.2. UNDERGROUND - SCH40 PVC 4.3. SUPPLY-SIDE / SERVICE ENTRANCE / WHERE SUBJECT TO DAMAGE - GALV. RIGID STEEL 5. EGC REFERS TO EQUIPMENT GROUNDING CONDUCTOR; GEC REFERS TO GROUNDING ELECTRODE CONDUCTOR. 6. ALL CONDUCTORS SHALL BE COPPER. 7. ELECTRICAL EQUIPMENT AND MATERIALS APPROVED, LISTED, LABELED, IDENTIFIED AND INSTALLED PER A NATIONALLY RECOGNIZED ELECTRICAL TESTING LABORATORY. 8. SERVICE EQUIPMENT LABELED PER NEC FOR DUAL SOURCES. PV EQUIPMENT/SYSTEM LABELING PER NEC 690. M Router, connection to Internet Provided by Customer SOLAR MODULES SOUTH & WEST-FACING ROOFTOPS [New / By Axium Solar] Trina Allmax 300W Modules (M/N: TSM-300DD05A.05) SolarEdge, P400 Optimizers MC4 connectors, PVWire module and optimizer leads. Modules are compatible with ungrounded / transformer-less inverter topology. Each module is attached to an optimizer. Optimizers are wired in series. Modules are UL 1703 listed. 2SWLPL]HUVDUHOLVWHG 8/8/Clips attached to module frames and wire tray on racking system support conductors. Modules bonded to racking system via UL listed module clamps. Optimizers bonded via #6 bare, solid EGC. Install ground lug on each independent array assembly. DC+ conductor jacket is red and DC- is black. Solar Modules Equipment Grounding Conductors (TYPICAL) #6 Bare within array, #10G THWN-2 in conduit Junction Box (AR) DC Conductors #10 PVWire per string of optimizers to Inverter 1#10G EGC THWN-2, 1" Raceway String of 15 Optimizers (15 modules) J SOLAR INVERTER TBD [New / By Axium Solar] SolarEdge Inverter (1) SE7600H-US 240V, NEMA 3R 32A Maximum Output Amps Integral Arc Fault protection Integral DC Disconnect Integral Rapid Shutdown Capable Inverter is listed, UL 1741 Monitoring means: SE Zigbee Wireless DC Optimizer Built-in DC Optimizer whips (#10 PVWire). Field-installed #10 PVWire jumpers installed as necessary. (TYPICAL) J String of 14 Optimizers (14 modules) WĞĞďůĞƐZĞƐŝĚĞŶĐĞͲWstŝƌĞĂůĐƵůĂƚŝŽŶƐ ^,ZdĞŵƉĞƌĂƚƵƌĞƐ dŽƚĂůƐ ŚĂƌĂĐƚĞƌŝƐƚŝĐƐ YƚLJ͘EŽŵŝŶĂů ^ŚŽƌƚͲŝƌĐƵŝƚ dĞŵƉĞƌĂƚƵƌĞŽĞĨĨŝĐŝĞŶƚƐ;йͬΣͿ ŽůĚĞƐƚĂLJsŽĐ tĂƌŵĞƐƚĂLJ sŵƉ Ϯй,ŝŐŚ;ΣͿ džƚƌĞŵĞDŝŶ;ΣͿ Ϯй,ŝŐŚ;Σ&Ϳ džƚƌĞŵĞDŝŶ ;Σ&Ϳ DŽĚƵůĞƐ ^dtĂƚƚƐͬ DŽĚƵůĞ ^LJƐƚĞŵ^ŝnjĞ;^d ŬtͿ WdtĂƚƚƐͬ DŽĚƵůĞ ^LJƐƚĞŵ^ŝnjĞ;Wd ŬtͿ /ŶǀĞƌƚĞƌĨĨŝĐŝĞŶĐLJ ^LJƐƚĞŵ^ŝnjĞ; ŬtͿDŽĚƵůĞƐsŵƉ /ŵƉ sŽĐ /ƐĐ sŽĐ /ƐĐ WŵĂdž ^ŝƚĞ ϯϳ Ͳϳ ϵϴ͘ϲ ϭϵ͘ϰ Ϯϵ ϯϬϬ ϴ͘ϳϬ ϮϳϬ͘ϲϬ ϳ͘ϴϱ ϵϲ͘Ϯй ϳ͘ϱϱ ^ŝŶŐůĞdƌŝŶĂůůŵĂdžWůƵƐϯϬϬt;d^DͲϬϱ͘Ϭϱ;//ͿͿ ϭ ϯϮ͘ϲϬ ϵ͘ϭϵ ϯϵ͘ϴϬ ϵ͘ϳϳ ͲϬ͘Ϯϵ Ϭ͘ϬϱϬ ͲϬ͘ϯϵ ϰϯ͘ϰϵ Ϯϳ͘Ϯϲ EŽƚĞ͗ĂůĐƵůĂƚŝŽŶƐƐŚŽǁŶĂƌĞďĂƐĞĚŽŶŝŶƐƚĂůůĂƚŝŽŶŽĨϵϬΣĐŽŶĚƵĐƚŽƌƐ͘^ŽŵĞĞƋƵŝƉŵĞŶƚůƵŐƐĂƌĞƌĂƚĞĚĂƚϳϱΣĂŶĚĐŽŶĚƵĐƚŽƌƐǀĞƌŝĨŝĞĚƚŽƌĞŵĂŝŶǁŝƚŚŝŶůŝŵŝƚƐ͘^ŽŵĞĐŽŶĚƵĐƚŽƌƐŵĂLJŚĂǀĞďĞĞŶƵƉƐŝnjĞĚĨŽƌǀŽůƚĂŐĞĚƌŽƉ͘ŽƉƉĞƌĐŽŶĚƵĐƚŽƌƐƵŶůĞƐƐŽƚŚĞƌǁŝƐĞŶŽƚĞĚŽŶĚƌĂǁŝŶŐƐ͘ EŽƚĞ͗Kh;ŽŶĚŝƚŝŽŶƐŽĨhƐĞͿŽƌƌĞĐƚĞĚŵƉƐƌĞĨĞƌƐƚŽĐŽŶĚƵĐƚŽƌĚĞƌĂƚŝŶŐ͘EdĂďůĞϯϭϬ͘ϭϱ;Ϳ;ϮͿ;Ϳ͕ϳϱΣĐŽůƵŵŶƵƐĞĚĨŽƌƚĞŵƉĞƌĂƚƵƌĞĚĞƌĂƚŝŶŐ͘EdĂďůĞϯϭϬ͘ϭϱ;Ϳ;ϯͿ;ĂͿƵƐĞĚĂƐĐŽŶĚƵŝƚĨŝůůĚĞƌĂƚŝŶŐ͘EdĂďůĞϯϭϬ͘ϭϱ;Ϳ;ϭϲͿƵƐĞĚĨŽƌĐŽŶĚƵĐƚŽƌĂŵƉĂĐŝƚLJ͘ EŽƚĞ͗ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞƐŽƵƌĐĞĚĨƌŽŵ^,ZϮйŚŝŐŚǀĂůƵĞƐĂŶĚĂƉƉƌŽƉƌŝĂƚĞƚĞŵƉĞƌĂƚƵƌĞĂĚĚĞƌĨƌŽŵEƚĂďůĞϯϭϬ͘ϭϱ;Ϳ;ϯͿ;ͿĂƉƉůŝĞĚ͘ŵƉĞƌĂŐĞĞƐĐĂůĂƚĞĚƚŽƐĞůĞĐƚĂƉƉƌŽƉƌŝĂƚĞĐŽŶĚƵĐƚŽƌ͘ ĂůĐƵůĂƚŝŽŶƐĂďŽǀĞďĂƐĞĚŽŶ͗;ŝĨĂƉƉůŝĐĂďůĞͿ KƉĞƌĂƚŝŶŐƵƌƌĞŶƚс;ηƐƚƌŝŶŐƐͿΎ;/ŵƉͿ KƉĞƌĂƚŝŶŐsŽůƚĂŐĞс;ηŵŽĚƵůĞƐŝŶƐĞƌŝĞƐͿΎ;sŵƉͿ ^ŚŽƌƚŝƌĐƵŝƚƵƌƌĞŶƚс;ηƐƚƌŝŶŐƐͿΎϭ͘ϮϱƉĞƌEϲϵϬ͘ϴ;Ϳ;ϭͿ DĂdž^LJƐƚĞŵsŽůƚĂŐĞс;ηŵŽĚƵůĞƐŝŶƐĞƌŝĞƐͿΎ΀;;;Ͳ͘ηηйsͬΣΎ͘ϬϭͿΎ;ůŽǁĞƐƚƚĞŵƉΣͲϮϱͿͿΎsŽĐͿͿнsŽĐͿ΁ SOLAR PV AC DISCONNECT [New / By Axium Solar] Fused Disconnect w/ 2 - 40A Fuses 2P, 60A, 240VAC NEMA 3R Enclosure Install 240V AC surge protection 3#8 THWN-2 1#10G THWN-2 Min. 3/4" Conduit Typical MAIN ELECTRICAL PANEL [Existing] 200 A MCB, 200 A Bus 240/120, 1ĭ, 3W Breakers are GE Q-Line type For solar interconnection, perform line-side tap of incoming supply feeders of main electrical panel. Install Sense energy monitor with added 20A/2P breaker in main panel. Shown installed inside panel board, but may work better to install externally using the supplied bracket. Visible, Lockable, Labeled Solar PV AC Disconnect (Located w/in 10' of utility meter) AC SPD 200AMain EŽƚĞ͗sĂůƵĞƐďĞůŽǁƌĞĨůĞĐƚĨĂĐƚƚŚĂƚƐƚƌŝŶŐƐĂƌĞŶŽƚĐŽŵďŝŶĞĚĂŶĚƐŚŽǁƚŽƚĂůŶƵŵďĞƌŽĨĐƵƌƌĞŶƚĐĂƌƌLJŝŶŐĐŽŶĚƵĐƚŽƌƐƌƵŶŝŶŚŽŵĞͲƌƵŶĐŽŶĚƵŝƚƚŽŝŶǀĞƌƚĞƌ͘;'ŝŶĐŽŶĚƵŝƚͿYƚLJ͘EŽŵŝŶĂů DĂdžŝŵƵŵ ŵƉƐ ŽŶƚ͘ƵƚLJ ŵƉƐ KW^ŝnjĞ;ŵƉƐͿ ƉƉƌŽdž͘KŶĞͲtĂLJ ŝƐƚĂŶĐĞ;Ĩƚ͘Ϳ ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ ;Σ&Ϳ dĞŵƉĞƌĂƚƵƌĞĚĚĞƌ ;Σ&Ϳ dĞŵƉĞƌĂƚƵƌĞ&ĂĐƚŽƌ ηƵƌƌĞŶƚĂƌƌLJŝŶŐ ŽŶĚƵĐƚŽƌƐ ŽŶĚƵŝƚ&ŝůů&ĂĐƚŽƌ WƌŽƚĞĐƚĞĚŵƉƐ KhŽƌƌĞĐƚĞĚ ŵƉƐ DŝŶŝŵƵŵtŝƌĞ ^ŝnjĞ ĂůĐƵůĂƚĞĚйsĚƌŽƉĂƚ DŝŶŝŵƵŵ ^ĞůĞĐƚĞĚtŝƌĞ ^ŝnjĞ ĂůĐƵůĂƚĞĚйsĚƌŽƉĂƚ ^ĞůĞĐƚĞĚ DŝŶŝŵƵŵ' ^ĞůĞĐƚĞĚ' KƉƚŝŵŝnjĞƌƐ sŽůƚƐ ŵƉƐ ^ŽůĂƌĚŐĞϳϲϬϬ^ƚƌŝŶŐηϭ ϭϱ ϰϬϬ ϭϭ͘Ϯϱ ϭϱ ϭϴ͘ϴ ŶĂ ϱϬ ϭϬϬ Ϭ Ϭ͘ϵϭ ϰ Ϭ͘ϴ ϭϴ͘ϴ Ϯϱ͘ϴ ϭϮ Ϭ͘ϱϲй ϭϬ Ϭ͘ϯϱй ϭϬ ϭϬ ^ŽůĂƌĚŐĞϳϲϬϬ^ƚƌŝŶŐηϮ ϭϰ ϰϬϬ ϭϬ͘ϱϬ ϭϱ ϭϴ͘ϴ ŶĂ ϱϬ ϭϬϬ Ϭ Ϭ͘ϵϭ ϰ Ϭ͘ϴ ϭϴ͘ϴ Ϯϱ͘ϴ ϭϮ Ϭ͘ϱϮй ϭϬ Ϭ͘ϯϯй ϭϬ ϭϬ ^ŽůĂƌĚŐĞϳϲϬϬ^ƚƌŝŶŐηϯ Ϭ ϰϬϬ Ϭ͘ϬϬ ϭϱ ϭϴ͘ϴ ŶĂ Ϭ ϭϬϬ Ϭ Ϭ͘ϵϭ ϰ Ϭ͘ϴ ϭϴ͘ϴ Ϯϱ͘ϴ ϭϮ Ϭ͘ϬϬй ϭϬ Ϭ͘ϬϬй ϭϬ ϭϬ DĂdžKƵƚƉƵƚ /ŶǀĞƌƚĞƌKƵƚƉƵƚ KW^ŝnjĞ;ŵƉƐͿ ƉƉƌŽdž͘KŶĞͲtĂLJ ŝƐƚĂŶĐĞ;Ĩƚ͘Ϳ ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ ;Σ&Ϳ dĞŵƉĞƌĂƚƵƌĞĚĚĞƌ ;Σ&Ϳ dĞŵƉĞƌĂƚƵƌĞ&ĂĐƚŽƌ ηƵƌƌĞŶƚĂƌƌLJŝŶŐ ŽŶĚƵĐƚŽƌƐ ŽŶĚƵŝƚ&ŝůů&ĂĐƚŽƌ WƌŽƚĞĐƚĞĚŵƉƐ KhŽƌƌĞĐƚĞĚ ŵƉƐ DŝŶŝŵƵŵtŝƌĞ ^ŝnjĞ ĂůĐƵůĂƚĞĚйsĚƌŽƉĂƚ DŝŶŝŵƵŵ ^ĞůĞĐƚĞĚtŝƌĞ ^ŝnjĞ ĂůĐƵůĂƚĞĚйsĚƌŽƉĂƚ ^ĞůĞĐƚĞĚ DŝŶŝŵƵŵ' ^ĞůĞĐƚĞĚ'sŽůƚƐ ŵƉƐ;WŚĂƐĞƐͿ ϭϮϱйŽĨDĂdžŵƉƐ /ŶǀĞƌƚĞƌƚŽWĂŶĞů ϮϰϬ ϯϮ ϯϮ ŶĂ ϰϬ͘Ϭ ϰϬ ϭϬϬ ϭϬϬ Ϭ Ϭ͘ϵϭ ϯ ϭ ϰϬ͘Ϭ ϰϰ͘Ϭ ϴ ϭ͘ϴϬй ϴ ϭ͘ϴϬй ϭϬ ϭϬ EAST EXTERIOR WALLSOUTH INTERIOR GARAGE WALL Ot h e r h o u s e l o a d s SE Zigbee Comms SenseUnit 20A/2P Sense Antenna Sense Circuit Breaker must be 2 pole (no tandum breakers) Sense CTs 1 set on incoming service lines, 1 set on PV input 40A DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 300W MODULES (1) SOLAREDGE 7.6KW INVERTER SNAPNRACK SERIES 100 RACKING 40° TILT 275° and 185° ORIENTATIONS Utility Meter, ESI ID# ? REVISIONS PROJECT: ADDRESS: C.D. PEEBLES SOLAR PV SYSTEM 1604 DEVON COURT SOUTHLAKE, TX 76092 ONE LINE ELECTRICAL PV 102 Fi l e : 1 0 2 O N E L I N E E L E C T R I C A L P l o t t e d : 1 1 / 1 1 / 2 0 1 9 C O P Y R I G H T © 2 0 1 9 A X I U M S O L A R , I N C . T h i s d o c u m e n t , t h e i d e a s a n d d e s i g n s i n c o rp o r a t e d h e r e i n a r e a n d s h a l l r e m a i n t h e P r o p e r t y o f A x i u m S o l a r , I n c . u n l e s s o t h e r w i s e s p e c i f i e d b y w r i t t e n c o n t r a c t . Th e s e d o c u m e n t s a r e n o t t o b e u s e d o r a l t e r e d , i n w h o l e o r i n p a r t , f o r o t h e r t h a n t h e o r i g i n a l i n t e n d e d u s e . CONSTRUCTION (855) 633-8680 (972) 633-8680 WWW.AXIUMSOLAR.COM 1005 PLACID AVE. SUITE 100 PLANO, TX 75074 11-11-2019; ELECTRICAL ONLY DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE REVISIONS PROJECT: ADDRESS: C.D. PEEBLES SOLAR PV SYSTEM 1604 DEVON COURT SOUTHLAKE, TX 76092 ATTACHMENT DETAIL PV 103 Fi l e : 1 0 3 A T T A C H M E N T D E T A I L P l o t t e d : 1 1 / 1 1 / 2 0 1 9 C O P Y R I G H T © 2 0 1 9 A X I U M S O L A R , I N C . T h i s d o c u m e n t , t h e i d e a s a n d d e s i g n s i n c o r p or a t e d h e r e i n a r e a n d s h a l l r e m a i n t h e P r o p e r t y o f A x i u m S o l a r , I n c . u n l e s s o t h e r w i s e s p e c i f i e d b y w r i t t e n c o n t r a c t . Th e s e d o c u m e n t s a r e n o t t o b e u s e d o r a l t e r e d , i n w h o l e o r i n p a r t , f o r o t h e r t h a n t h e o r i g i n a l i n t e n d e d u s e . CONSTRUCTION For Reference Only Refer to separate, stamped engineering report and calculations for roof mounting. 7ULQD$OO0D[0RGXOHVWREH EHWZHHQDQG DQGLQ/DQGVFDSH TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 300W MODULES (1) SOLAREDGE 7.6KW INVERTER(S) SNAPNRACK SERIES 100 RACKING 40° & ----° TILT(S) 275° & 185° ORIENTATION(S) Utility Meter, ESI ID# ? (855) 633-8680 (972) 633-8680 WWW.AXIUMSOLAR.COM 1005 PLACID AVE. SUITE 100 PLANO, TX 75074 HT # 558-00312, Continuous, Red Vinyl, 2" width (1 each) PV POWER SOURCE (INVERTER) "INVERTER 1" MAX AMPS 32 A AC MAX VOLTS 240 V AC HT # 596-00496, pre-printed, (qty. 1) HT # 596-00241, roll, custom printed fields, (qty. 1) INVERTER 1 LABELING OPERATING CURRENT: PHOTOVOLTAIC SYSTEM DC DISCONNECT OPERATING VOLTAGE: MAXIMUM SYSTEM VOLTAGE: SHORT CIRCUIT CURRENT: 11.3 400 400 15 WARNING DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ELECTRICAL SHOCK HAZARD DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT OPERATING CURRENT: PHOTOVOLTAIC AC DISCONNECT OPERATING VOLTAGE: 32 240 HT # 596-00676, roll, pre-printed, (qty. 1) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT MAIN PV DISCONNECT LABELING HT # 596-00239, roll, pre-printed, (qty. 1) HT # 596-00499, roll, pre-printed, (qty. 1) HT # 596-00495, roll, pre-printed, (qty. 1) WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL DUAL POWER SOURCEWARNING SECOND SOURCE IS PHOTOVOLTAIC SYSTEM TIE-IN PANEL LABELING HT # 596-00633, White with Orange Warning Header, 4" height, 6" width POWER TO THIS SERVICE EQUIPMENT IS ALSO SUPPLIED BY ON-SITE SOLAR SYSTEMS DISCONNECT LOCATED WITHIN 10 FEET OF METER THIS TRANSFORMER IS SUPPLIED BY BOTH UTILITY AND SOLAR POWER SOURCES DISCONNECTS LOCATED ON ADJACENT BLDG MAX PV AMPS 32 A AC MAX PV VOLTS 240 V AC WARNING WARNING METER BASE / TRANSFORMER POLE LABELING (REPLACEMENT) WARNING: PHOTOVOLTAIC POWER SOURCE DC Raceways (every 10', every turn, above and below penetrations) - (AR) 1" x 9" HT # 596-00497, roll, pre-printed, (qty. 1) DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. WARNING ELECTRICAL SHOCK HAZARD ALL DC JUNCTION BOXES/SOLADECKS HT # 596-00588, pre-printed, (qty. 2) WARNING THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD HT # 596-00588, pre-printed, (qty. 1) WARNING THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD HT # 558-00312, Continuous, Red Vinyl, 2" width (5 each) PV JUNCTION BOX (DC) MAX AMPS/STRING 15 A DC TYP AMPS/STRING 11.3 A DC MAX VOLTAGE 400 V DC SafeDC VOLTAGE 15 V DC DC J-BOX LABELING THIS SYSTEM RUNS AT FIXED DC VOLTAGE WHEN INVERTER IS ENERGIZED AND EMPLOYS SafeDC TO LIMIT DC VOLTAGE WHEN INVERTER IS OFF. PVLables.com p/n 05-112, pre-printed, (qty. 1) REVISIONS PROJECT: ADDRESS: Fi l e : 1 0 4 L A B E L S P l o t t e d : 1 1 / 1 1 / 2 0 1 9 C O P Y R I G H T © 2 0 1 9 A X I U M S O L A R , I N C . T h i s d o c u m e n t , t h e i d e a s a n d d e s i g n s i n c o r p o r a t e d h e r e in a r e a n d s h a l l r e m a i n t h e P r o p e r t y o f A x i u m S o l a r , I n c . u n l e s s o t h e r w i s e s p e c i f i e d b y w r i t t e n c o n t r a c t . Th e s e d o c u m e n t s a r e n o t t o b e u s e d o r a l t e r e d , i n w h o l e o r i n p a r t , f o r o t h e r t h a n t h e o r i g i n a l i n t e n d e d u s e . DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 300W (1) SOLAREDGE 7.6KW SNAPNRACK SERIES 100 RACKING 40° TILT 275° & 185° ORIENTATION(S) Utility Meter, ESI ID# ? 1604 DEVON COURT SOUTHLAKE, TX 76092 LABELS PV 104 CONSTRUCTION C.D. PEEBLES SOLAR PV SYSTEM (855) 633-8680 (972) 633-8680 WWW.AXIUMSOLAR.COM 1005 PLACID AVE. SUITE 100 PLANO, TX 75074 11-11-2019; ELECTRICAL ONLY