Loading...
Item 9Case No. ZA19-0076 S T A F F R E P O R T January 3, 2019 CASE NO: ZA19-0076 PROJECT: Specific Use Permit for a Residential Solar Energy System EXECUTIVE SUMMARY: Green Light Solar Systems, on behalf of the owner, Corrie Decamp, is requesting approval of a Specific Use Permit for a Residential Solar Energy System on property described as Lot 2, Block 2, Randol Mill Estates, an addition to the City of Southlake, Tarrant County, Texas and located at 1781 Kingswood Drive, Southlake, Texas Current Zoning: “SF-1A” Single Family Residential District. SPIN Neighborhood #5. DETAILS: The applicant is requesting approval to add a residential solar energy system on the residence. The proposed solar array for the house consists of 45 solar energy panels (each panel is approximately 39.33” by 65.51”) totaling approximately 787.5 square feet and located on three (3) roof areas (rear, west, and rear east) and generally oriented south and west. The existing system produces 13.95 kW . Additional information may be found in the specific use permit plans. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Specific Use Permit Request for a Residential Solar Energy System ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Specific Use Permit Staff Review No. 2 dated January 3, 2020 (D) Surrounding Property Owners Map (E) Surrounding Property Owners Responses (F) Resolution No. 19-046, Specific Use Permit for a Residential Solar Energy System Full Size Plans (for Commission and Council Members only) PowerPoint Presentation Plans STAFF CONTACT: Dennis Killough (817) 748-8072 Patty Moos (817) 748-8269 Case No. Attachment A ZA19-0076 Page 1 BACKGROUND INFORMATION APPLICANT: Green Light Solar Systems OWNER: Corrie Decamp PROPERTY SITUATION: 1781 Kingswood Drive, Southlake, Texas LEGAL DESCRIPTION: Lot 2, Block 2, Randol Mill Estates LAND USE CATEGORY: Low Density Residential CURRENT ZONING: “SF-1A” Single Family Residential District HISTORY: The property was designated as “SF-1A” Single Family Residential District with the adoption of the Zoning Ordinance No 480 and the official Zoning Map on September 19, 1989. A certificate of occupancy was issued for the existing house in December 1985. TRANSPORTATION ASSESSMENT: This request does not affect traffic on or around the property. TREE PRESERVATION: The proposed solar panels are to be installed on the rear and side roof areas of the existing home; no trees will be affected by the request. STAFF COMMENTS: Staff review may be found in the Specific Use Permit Summary No. 2 dated January 3, 2020. Note: A specific use permit shall automatically expire if a building permit is not issued and construction begun within six (6) months of the granting of the specific use permit or if the use shall cea se for a period of six (6) months. Note: The roof structure must be engineered to handle the load of the solar panels. 45.5 FACTORS TO BE CONSIDERED - In granting or denying an application for a specific use permit, the City Council shall take into consideration the following factors: a. Safety of the motoring public and of pedestrians using the facility and the area immediately surrounding the site. b. Safety from fire hazard, and measures for fire control. c. Protection of adjacent property from flood or water damage. d. Noise producing elements; and glare of vehicular and stationary lights and effect of such lights on established Case No. Attachment A ZA19-0076 Page 2 character of the neighborhood. e. Location, lighting and type of signs; and relation of signs to traffic control and adverse effect on adjacent properties. f. Street size and adequacy of pavement width for traffic and reasonably expected to be generated by the proposed use around the site and in the immediate neighborhood. g. Adequacy of parking, as determined by requirements of this chapter for off-street parking facilities for similar uses; location of ingress and egress points for parking and off - street loading spaces; and protection of the public health by all-weather surfacing on all parking areas to control dust. h. Such other measures as will secure and protect the public health, safety, morals and general welfare. i. City Council may grant variances to specific regulations associated with a specific use set forth in Sections 45. To receive a variance, the applicant must demonstrate one of the following (As amended by Ordinance No. 480 - MMMM): (a) A variance will reduce the impact of the project on surrounding residential properties; or (b) Compliance with this ordinance would impair the architectural design or creativity of the project; or (c) A variance is necessary to assure compatibility with surrounding developed properties; or (d) The proposed construction is an addition to an existing project that does not meet the requirements of this ordinance. 45.17 SPECIFIC REGULATIONS FOR SOLAR ENERGY SYSTEMS (As amended by Ordinance No. 480-WWW) The purpose of this section is to establish standards for Solar Energy Systems. A Solar Energy System shall be approved by City Council through the Specific Use Permit process and may be subject to other requirements as deemed necessary. RESIDENTIAL ZONES Ground Mounted Systems: a. Front Yard: No system shall be located forward of the principal building on the lot. b. Side and Rear: No system shall be located less than ten (10) feet from any side or rear property line. Roof Mounted Systems: Case No. Attachment A ZA19-0076 Page 3 a. Height: No system shall be installed greater than six (6) inches between the panel and roof. ALL ZONES a. No solar energy system shall be constructed upon a lot until a building permit has been issued or principal use has actually been commenced. b. A line of sight analysis will be required in addition to the applicable submittal requirements under Section 40 (Development Plans and Site Plans) of the City of Southlake Zoning Ordinance. N:\Community Development\MEMO\2019 Cases\0076 - SUP- Solar Panel System - 1781 Kingswood Drive Case No. Attachment B ZA19-0076 Page 1 Case No. Attachment C ZA19-0076 Page 1 SPECIFIC USE PERMIT REVIEW SUMMARY Case No.: ZA19-0076 Review No.: Two Date of Review:1/3/19 Project Name: Specific Use Permit for a Residential Solar Panel System APPLICANT: Amy Carlisle OWNER: Corrie Decamp 1539 Central Park Drive 1781 Kingswood Drive Hurst, TX 76053 Southlake, TX 76092 Phone: 817-487-7759 Phone: 817-266-0453 Email: amy@gl.solar Email: CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 1/3/19 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT Patty Moos AT (817) 748-8269. __________________________________________________________________________________________ Planning Review Patty Moos Planner I Phone: (817) 748-8269 Email: pmoos@ci.southlake.tx.us 1. The distance from the roof to the bottom of the solar panel at the roof mount must not to exceed 6 inches. NOTE: A building permit must be issued prior to installation of the solar panels . NOTE: A specific use permit shall automatically expire if a building permit is not issued and construction begun within six (6) months of the granting of the specific use permit or if the use shall cease for a period of six (6) months _________________________________________________________________________________ Fire Department Kelly Clements Fire Marshal Phone: (817) 748-8233 E-mail: kclements@ci.southlake.tx.us GENERAL COMMENTS: Solar photovoltaic power systems must comply with Section 1204 of the 2018 International Fire Code. See the fire code information at the end of this review. _________________________________________________________________________________ General Information 45.17 SPECIFIC REGULATIONS FOR SOLAR ENERGY SYSTEMS (As amended by Ordinance No. 480-WWW) Case No. Attachment C ZA19-0076 Page 2 The purpose of this section is to establish standards for Solar Energy Systems. A Solar Energy System shall be approved by City Council through the Specific Use Permit process and may be subject to other requirements as deemed necessary. RESIDENTIAL ZONES Ground Mounted Systems: c. Front Yard: No system shall be located forward of the principal building on the lot. d. Side and Rear: No system shall be located less than ten (10) feet from any side or rear property line. Roof Mounted Systems: b. Height: No system shall be installed greater than six (6) inches between the panel and roof. ALL ZONES c. No solar energy system shall be constructed upon a lot until a building permit has been issued or principal use has actually been commenced. d. A line of sight analysis will be requi red in addition to the applicable submittal requirements under Section 40 (Development Plans and Site Plans) of the City of Southlake Zoning Ordinance. 2018 INTERNATIONAL FIRE CODE SECTION 1204 SOLAR PHOTOVOLTAIC POWER SYSTEMS 1204.l General. Solar photovoltaic systems shall be installed in accordance with Sections 1204.2 through 1204.5, and the International Building Code or International Residential Code. The electrical portion of solar PV systems shall be installed in accordance with NFPA 7 0. 1204.2 Access and pathways . Roof access, pathways, and spacing requirements shall be provided in accordance with Sections 1204.2.1 through 1204.3.3. Pathways shall be over areas capable of supporting fire fighters accessing the roof. Pathways shall be located in areas with minimal obstructions, such as vent pipes, conduit or mechanical equipmen t. Exceptions: 1. Detached, non-habitable Group U structures including, but not limited to, detached garages serving Group R-3 buildings, parking shade structures, carports, solar trellises and similar structures. 2. Roof access, pathways and spacing requirements need not be provided where the fire code official has determined that rooftop operations will not be employed. 1204.2.1 Solar photovoltaic systems for Group R-3 buildings. Solar photovoltaic systems for Group R-3 buildings shall comply with Sections 1204.2.1.1 through 1204.2.1.3. Case No. Attachment C ZA19-0076 Page 3 Exceptions: 1. These requirements shall not apply to structures designed and constructed in accordance with the International Residential Code. 2. These requirements shall not apply to roofs with slopes of 2 units vertical in 12 units horizontal or less. 1204.2.1.1 Pathways to ridge. Not fewer than two 36- inch-wide (914 mm) pathways on separate roof planes, from lowest roof edge to ridge, shall be provided on all buildings. Not fewer than one pathway shall be provided on the street or driveway side of the roof. For each roof plane wi th a photovoltaic array, not fewer than one 36 -inch-wide (914 mm) pathway from lowest roof edge to rid ge shall be provided on the same roof plane as the photovoltaic array, on an adjacent roof plane or straddling the same and adjacent roof planes. 1204.2.1.2 Setbacks at ridge. For photovoltaic arrays occupying 33 percent or less of the plan view total roof area, a setback of not less than 18 inches (457 mm) wide is required on both sides of a horizontal ridge. For photovoltaic arrays occupying more than 3 3 percent of the plan view total roof area, a setback of not less than 36 inches (457 mm) wide is requ ired on both sides of a horizontal ridge. 1204.2.1.3 Alternative setbacks at ridge. Where an automatic sprinkler system is installed within the dwelling in accordance with Section 903.3.1.3, set-backs at the ridge shall conform to one of the following: 1. For photovoltaic arrays occupying 66 percent or less of the plan view total roof area, a setback of not less than 18 inches (457 mm) wide is required on b oth sides of a horizontal ridge. 2. For photovoltaic arrays occupying more than 66 percent of the plan v iew total roof area, a setback of not less than 36 inches (914 mm) wide is required on both sides of a horizontal ridge. 1204.2.2 Emergency escape and rescue openings. Panels and modules installed on Group R -3 buildings shall not be placed on the portion of a roof that is below an emergency escape and rescue opening. A pathway of not less than 36 inches (914 mm) wide shall be provided to the emergency escape and rescue opening. 1204.3 Other than Group R-3 buildings. Access to systems for buildings, other than those containing Group R-3 occupancies, shall be provided in accordance with Sections 1204.3.1 through 1204.3.3. Exception: Where it is determined by the fire code official that the roof configuration is similar to that of a Group R-3 occupancy, the residential access and ventilation requirements in Sections 1204.2.1.1 through 1204.2.1.3 are a suitable alternative. 1204.3.1 Perimeter pathways. There shall be a minimum 6-foot-wide (1829 1mn) clear perimeter around the edges of the roof. Case No. Attachment C ZA19-0076 Page 4 Exception: Where either axis of the building is 250 feet (76 200 mm) or less, the clear perimeter around the edges of the roof shall be permitted to be reduced to a minimum widt h of 4 feet (1219 mm). 1204.3.2 Interior pathways. Interior pathways shall be provided between array sections to meet the following requirements: 1. Pathways shall be provided at intervals not greater than 150 feet (45 720 mm) throughout the length and width of the roof. 2. A pathway not less than 4 feet (1219 mm) wide in a straight line to roof standpipes or ventilation hatches. 3. A pathway not less than 4 feet (1219 mm) wide around roof access hatches, with not fewer than one such pathway to a parape t or roof edge. 204.3.3 Smoke ventilation. The solar installation shall be designed to meet the following requirements: 1. Where non-gravity operated smoke and heat vents occ ur, a pathway not less than 4 feet (1219 mm) wide shall be provided bordering all sides. 2. Smoke ventilation options between array sections shall be one of the following: 2.1. A pathway not less than 8 feet (2438 mm) wide. 2.2. Where gravity-operated dropout smoke and heat vents occur, a pathway not less than 4 feet (1219 mm) wide on not fewer than one side. 2.3. A pathway not less than 4 feet (1219 1mn) wide bordering 4 -foot by 8-foot (1219 mm by 2438 mm) venting cutouts every 20 feet(6096 mm) on alternating sides of the pathway. 1204.4 Ground-mounted photovoltaic panel systems. Ground-mounted photovoltaic panel systems shall comply with Section 1204.1 and this section. Setback requir ements shall not apply to ground-mounted, free-standing photovol-taic arrays. A clear, brush-free area of 10 feet (3048 mm) shall be required for ground-mounted photovoltaic arrays. 1204.5 Buildings with rapid shutdown. Buildings with rapid shutdown solar photovoltaic systems shall have perma-nent labels in accordance with Sections 1204.5.1 through 1204.5.3. 1204.5.1 Rapid shutdown type. The type of solar photo-voltaic system rapid shutdown shall be labeled with one of the following: 1. For solar photovoltaic systems that shut down the array and the conductors leaving the array, a label shall be provided. The first two lines of the label shall be uppe rcase characters with a minimum height of ¾- inch (10 mm) in black on a yellow background. The remaining characters shall be uppercase with a minimum height of 3/16 inch (5mm) in black on a white background. The label shall be in accordance with Figure 120 4.5.1(1) and state the following: Case No. Attachment C ZA19-0076 Page 5 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHU1DOWN. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY. 2. For photovoltaic systems that only shut down con-ductors leaving the array, a label shall be provided. The first two lines of the label shall be uppercase characters with a minimum height of 3/8 inch (10mm) in white on a red background and the remaining characters shall be capitalized with a minimum height of 3/16 inch (5 mm) in black on a white background. The label shall be in accordance with Figure 1204.5.1(2) and state the following: THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUC-TORS OUTSIDE THE ARRAY. CONDUC-TORS WITHIN ARRAY REMAIN ENERGIZED IN SUNLIGHT. 1204.5.1.1 Diagram. The labels in Section 1204.5.1 shall include a simple diagram of a building with a roof. Diagram sections in red signify sections of the solar photovoltaic system that are not shut down when the rapid shutdown switch is turned off. 1204.5.1.2 Location. The rapid shutdown label in Section 1204.5.1 shall be located not greater than 3 feet (914 mm) from the service disconnecting means to which the photovoltaic systems are connected and shall indicate the location of all identified rapid shut-down switches if not at the same location. 204.5.2 Buildings with more than one rapid shutdown type. Solar photovoltaic systems that contain rapid shut-down in accordance with both Items 1 and 2 of Section 1204.5.1 or solar photovoltaic systems where only por-tions of the systems on the building contain rapid shut-down, shall provide a detailed plan view diagram of the roof showing each different Case No. Attachment C ZA19-0076 Page 6 photovoltaic system and a dot-ted line around areas that remain energized after the rapid shutdown switch is operated. 1204.5.3 Rapid shutdown switch. A rapid shutdown switch shall have a label located not greater than 3 feet (914 mm) from the switch that states the following: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM Case No. Attachment D ZA19-0076 Page 1 Surrounding Property Owners Residential Solar Energy System SPO # Owner Zoning Address Acreage Response 1. BELL, JAMES ALAN SF1-A 1794 KINGSWOOD DR 1.19 NR 2. ADDISON, HOWARD SF1-A 1796 KINGSWOOD DR 1.13 NR 3. MARTIN, KURT C SF1-A 1798 KINGSWOOD DR 1.14 NR 4. HALL, BRADLEY W SF1-A 1801 KINGSWOOD DR 1.21 NR 5. DIDYCH, OLEKSANDR SF1-A 1797 KINGSWOOD DR 1.16 NR 6. GLASER, MICAHEL SF1-A 1795 KINGSWOOD DR 1.18 NR 7. KRIESMAN, TRACI SF1-A 1791 KINGSWOOD DR 1.18 NR 8. HARRIGER, GARY W SF1-A 1789 KINGSWOOD DR 1.10 NR 9. HAMES, ROBERT SF1-A 1787 KINGSWOOD DR 1.05 NR 10. WHITSETT, LYLE D SF1-A 1785 KINGSWOOD DR 1.01 NR 11. CRAIG, RONNIE D SF1-A 1783 KINGSWOOD DR 1.02 NR 12. DECAMP, CORRIE SF1-A 1781 KINGSWOOD DR 0.97 NR 13. TEXAS, STATE OF RPUD 2116 PALOMAR TR 0.04 NR 14. VERBICK, TREY A RPUD 2112 PALOMAR TR 0.56 NR 15. GRICE, JOHN C SF1-A 1800 KINGSWOOD DR 1.35 NR 16. ANDERSON, GRAHAM SF1-A 1788 KINGSWOOD DR 1.37 NR 17. HARRILL CONSTRUCTION LLC SF1-A 1790 KINGSWOOD DR 1.18 NR 18. STORY, BRANDON KEITH SF1-A 1792 KINGSWOOD DR 1.20 NR 19. KENNEDY, MARK RPUD 2108 PALOMAR TR 0.57 NR 20. 5897 LIVING TRUST RPUD 2104 PALOMAR TR 0.66 NR 21. TRUMPHELLER, KENNETH SF1-A 1793 KINGSWOOD DR 1.20 NR Case No. Attachment D ZA19-0076 Page 2 22. 985 RANDOL MILL LP RPUD 2117 PALOMAR TR 0.32 NR 23. SOUTHLAKE, CITY OF SF1-A 1779 KINGSWOOD DR 0.44 NR 24. HALE, JAMES V SF1-A 1784 KINGSWOOD DR 0.97 NR 25. REZNIK, ROBERT L SF1-A 1782 KINGSWOOD DR 0.97 O 26. REZNIK, ROBERT L SF1-A 1780 KINGSWOOD DR 0.34 O 27. SOUTHLAKE, CITY OF SF1-A 1778 KINGSWOOD DR 0.15 NR 28. THE TEMPLE FAMILY LIVING TRUST SF1-A 1786 KINGSWOOD DR 1.18 NR 29. Superintendent of Carroll ISD 2400 N Carroll Ave NR 30. Superintendent of Grapevine Colleyville ISD 3051 Ira E Woods Ave NR 31. Superintendent of Northwest ISD PO Box 77070 NR 32. Superintendent of Keller ISD 350 Keller Pkwy NR 33. City of Keller P.O. Box 770 NR Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Thirty (30) Responses Received: In Favor: 0 Opposed: 1 Undecided: 0 No Response: 29 Case No. Attachment E ZA19-0076 Page 1 Surrounding Property Owners Responses Case No. Attachment F ZA19-0076 Page 1 RESOLUTION NO. 19-046 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS, GRANTING A SPECIFIC USE PERMIT FOR A SOLAR ENERGY SYSTEM ON RESIDENTIAL PROPERTY WITHIN THE CITY OF SOUTHLAKE, TEXAS, LOCATED AT 1781 KINGSWOOD DRIVE, BEING DESCRIBED AS LOT 2, BLOCK 2, RANDOL MILL ESTATES, AN ADDITION TO THE CITY OF SOUTHLAKE AS DEPICTED ON THE APPROVED SITE EXHIBIT ATTACHED HERETO AND INCORPORATED HEREIN AS EXHIBIT “A” AND PROVIDING AN EFFECTIVE DATE. WHEREAS, a Specific Use Permit for a Solar Energy System on residential property has been requested by a person or corporation having a proprietary interest in the property zoned as “SF-1A” Single Family Residential District; and, WHEREAS, in accordance with the requirements of Section 45.1 (45) and 45.17 of the City’s Comprehensive Zoning Ordinance, the Planning and Zoning Commission and the City Council have given the requisite notices by publication and otherwise, and have afforded the persons interested and situated in the affected area and in the vicinity there of; and, WHEREAS, the City Council does hereby find and determine that the gran ting of such Specific Use Permit is in the best interest of the public health, safety, morals and general welfare of the City. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS: SECTION 1. A Specific Use Permit is hereby granted for a Solar Energy System on residential property on 1781 Kingswood Drive being described as Lot 2, Block 2, Randol Mill Estates, City of Southlake as depicted on the approved Site Exhibit attached hereto and incorporated herein as Exhibit “A” and providing an effective date, subject to the provisions contained in the comprehensive zoning ordinance and the restrictions set forth herein. Case No. Attachment F ZA19-0076 Page 2 SECTION 2. This resolution shall become effective on the date of approval by the City Council. PASSED AND APPROVED THIS _______ DAY OF _________, 2020. CITY OF SOUTHLAKE By: _________________________________ Laura Hill, Mayor ATTEST: _________________________________ Amy Shelley City Secretary Case No. Attachment F ZA19-0076 Page 3 EXHIBIT ‘A” Plans and Support Information Reserved for exhibits