Item 9 - PlansSYSTEM RAT ING
ROOF-1 7 .130 kW DC STC
ROOF-2 2 . 790 kW DC STC
ROO F-3 4 .030 kW DC S TC
TOTAL: 13 .950 kW DC STC
EQUI PM EN T SU MMA RY
4 5 MI SSION SOLAR 31 0 -W MODULES
45 ENPHASE 107 MICRO INVERTERS
SHEET INDEX
PV-1 COVER
PV-2 SI TE PL AN
S-1 ROOF 1
S-2 ROOF 2
S-3 ROO F 3
PV-3 MOUN TING DETA IL
PV-3.1 MOU NTIN G DET AIL
PV-3.2 MOU NTIN G DET AI L
PV-4 SPEC SHEET S
PV-5 SPEC SHEE TS
PV-6 SPEC SHEETS
E-1 ELECTRICAL DIAGRA M
E-2 SIGNAGE
GOVERN ING COD ES
2017 NA TI ON AL ELEC TRICA L CODE
UND ER WRITERS LABORATORIES (UL) STANDARDS
1741 FOR INVER TERS, 1703 FOR MODULES
201 5 IRC IN TERNATIO NAL RES IDEN TI A L CODE
AER IA L VIEW
DESIGN & DRAFTING B Y:
DANA HAJEOEMOS
NABCEP: PV-100 414-010 500
OESCRIPnON OA TE RE V
ORIGINAL 1/15/2019 A
G reen Light
SOL AR SYSTEMS
PROJECT NAME
SHEET NAME
SHEET S IZE
11"x1 7"
SHEET NUMBER
P V -1
Ll
.d'
<1.d
SITE PLAN
.<1
<i
<1
Ll
.·
.d
.Ll
..
~
.<1
<1
<1
.d
·Ll
<1
.d . .d <1
<1.
Ll
.d <1.d
. .d
( 45) MISSION SOLAR 31 0-W MODULES TOTAL, 13.950 kW DC STC
.L}
.d <1 t--+--+---1
<1~
D
( 45) EN PHASE ENERGY INC. 107-60-x-US (240V) MICROINVERTERS, TOTAL 10.800 kW AC
SINGLE STORY ACCESS
FLUSH MOUNTED ROOF ARRAYS: COMP SHINGLE ROOFING
ROOF /ARRAY #1 -23"Pitch , 270'Azimuth -(19) MODULES
ROOF /ARRAY #2 -34'Pitch, 90'Azimuth -(8) MODULES
ROOF /ARRAY #3 -34'Pitch, 180'Az i muth -(18) MODULES
DRAWING SCALE: 3/32"=1'-0"
AGGREGATE PANEL
V AC DISCONNECT
TILITY METER
0
0
0
DISTRIBUTION PANEL
s
0
0
l
D
DESIGN & DRAFTING BY:
DANA HAJEDEMOS
NABCEP: PV-1 00414-010500
REVISIONS
DESCRIPTION DATE REV
ORIGINAL 1/15/2019 A
REVISION 1/2/2020
G reen light
SOLAR SYSTEMS
PROJECT NAME
SHEET NAME
SITE MAP
SHEET SIZE
SHEET NUMBER
PV-2
/40 IRONRIDGE
Sol ar Is Not Always Sunny
O ver the ir lifetim e, solar p anels experience co u ntl ess
extrem e weather event s. Not j ust t he worst storms in yea rs,
bu t t he worst st orm s in 40 years. High winds capable of
r ipping pa nels from a roof, and snowfall s weig hi ng
eno ugh to buckle a p an el frame .
XR Ra ils are the s tructu ral backbo ne preven t ing
th ese resu lts. They resist u p lift , p rotec t
against bu cklin g and safe ly and effic iently
tr a ns fer loads into the b u ilding stru cture.
T heir su pe ri or spanning capabi lity
requires fewer roof attachments,
reducing the number of roof
penetrat ion s an d the amou nt
of insta ll ation t ime.
Force-Stabilizing Curve
Sloped roofs generate both vertical and lateral
forces on mounting rails which can cause them
to bend and twi st . The curved shape of XR Rails
Is specially designed to increase strength In both
directions while r esisting the twisting. This unique
feat ure ensures greater secu rity during extreme
weather and a longer system lifet ime.
XR Rail Family
_, ............. ,,, I
----~OFT \\ l: ~ '\~~ .......... ff:t: \\
IJ ~ ~ .... * '1d' ., *'~·: ..• 1, , • : ·. * , .... ~ ...................... : .... ~
'-ROGER LEWIS BLAIR I ~································.,! ,,-<J .... 110564 /,..,1 '1 ~·· •'9J ' t, O~··.~(CENS~~···~«<_:"
\ ~$. ''"~~ I
~~-
No er 16,2019
Texas Firm No. F-15209
Compatible with Flat & Pitched Roofs C orrosio n-Resis t ant M a teri al s
11 XR Rails are rl lronRidge offers
compatible w ith ~ ~ a range of tilt leg
FlashFoot and liJ options for fla t
other pitc hed roof I roof mounting
allachments. apphcahons.
All XR Rails are made ot marine-grade
aluminum alloy, then protect ed wi th an
anodized finish. Anodizing prevents su rface
and structural corrosion, whil e also providing
a m ore attracti ve appearance.
XR Ra i l Family
The XR Rail Family offers the strength of a curved ra il in three targeted si zes. Each size su pports specif ic
design loads, whi le m inimiz ing material costs. Depend ing on you r location , there is an X R Rai l to match.
XR10
X R 1 0 is a sleek, tow-profil e mounting
ra il, desig ned for regi o ns with light or
no snow. It achieves 6 foot spans, white
remaining tight and economical.
6' spannin g capabili ty
Moderate load capability
C lear anodized finish
Internal splices available
Rail Selection
XR100
XR 1 00 Is the ultimate residential
mounting rail. II supports a range of
w ind and snow condit ions. wh ite also
maximizing spans up to 8 feet.
8' spanning capability
Heavy toad capability
C lear & black anodized tinish
Internal splices available
XR1000
XR 1000 is a heavyweight among
so lar mounting rails. It 's built to hand le
extreme climates and spans 12 feet o r
more for commercial applications.
12' spanning capability
Extreme toad capability
C lear anodized finish
Internal splices available
The following tabl e was prepared in compl ian ce wit h applicable engi ne eri ng codes and standards. Values are
based on the following crite ria : ASCE 7-10, Roof Zone 1, Exposu re B , Ro of S lope of 7 to 27 degrees and Mean
Building Height of 30ft. Vis it lronR id ge .com for detailed span tables and certifications.
Load . :
100
120
None
140 XR10 XR100 XR1000
160
100
120
10-20
140
160
100
30
160
100
40
160
50-70 160
80-90 160
DANA HAJEDE t.i OS t)ESIGN & DRAFTING BY:
3CEP : PV-100414-0105 00
R
OESCRIPnON REV
ORIGINAL 1/15/2019 A
G reen light
SOL/\R SYSTEMS
PROJECT NAME
SHEET NAM E
MOUNTI NG
DETA IL
SHEE T SIZE
11 "x17"
SHEET NUMBER
PV -3
d¢ IRONRIDGE
The Strongest Attachment in So l ar
lronRidge FlashFoot2 raises the bar in solar roof
protection. Th e unique water seal design is bot h
elevated and encapsulat ed , deliverin g red un dant laye rs
of protection against water intrusion. In addition , the
twi st-on Cap perfectly aligns the rail attachment wi th the
lag bo lt to maximize mech an ical strength .
Twist -On Cap
FlashFoo12's u nique Cap design encapsulates
the lag boll and locks into place with a simple
twist. The Cap helps Flash Foot2 deliver
superior stru ctu ral strength, by aligning
the rail and lag boll in a concentric
load path. _ ......... ,,,,,
---~OF r,. \\ -A.~~ ........ ,c;.; \\
;' C:>~···''*''•4U' '1 , . . ' ,.... ....,, ,.: ~. , .... ~ ...................... : .... ~
I ROGER LEWIS BLA IR I ~································' ,, -o\ 11 0 5 6 4 /,_ : 'A '• ··~, '• o;_· .. ~fCENS~~···~~ ..:' ' ~88io'NASg:?: ~i)W,z;L-
N:Q b~r 16 ,2019
Texas Firm No. F-15209
Single Socket Size
A custom·design lag boll allows
you to install F lashFoot2 w ith
the same 7/16" socket size
u sed o n other Flu sh Mount
System components.
FlashFoot2
FlashFool2's seal architecture utilizes three
layers ol protection . An elevated plallorm
diverts water away. while a slack of rugged
co mponents r aises the seal an entire inch .
The seal is th en fully·encapuslaled by th e
Cap. FlashFoot2 is the first solar allachment
to pass the TAS·H>O Wind·Oriven Rain Test.
An elevated plallorm diverts water
away from the water seal.
Installation Features
0 Alignment Markers
Quickly align the flashing with c halk line s to find pilot hole s.
@ Rounded Corners
Makes it easier to handle and insert under the roo f shingles .
Benefits of Concentric Loading
Traditional solar attachments have a
horizontal offset b etween th e ra il and lag
bolt, which introduces leverage on the lag
bolt and decreases uplift capacity.
@ Reinfo rcement Ribs
Help to st iffen the fl as hin g an d prevent any bending or
crinkling during installation.
Vl
€ e;. ·c;
"' a.
"' u
1200
•fl,thFoot2
1000 ~ ... '
800
600
400
.......... • FlalhFoot
•L••c{Lno~ompet itor
~ a. .... Low·Colt Competitor
FlashFoot2 is the only produ ct to align the
rail and lag bolt. This concentric loading
design results in a stronger attachment for
the sys tem.
Testing & Certification
Structural Certification
::> 200
0
Ra il-to-Lag Offse t (in)
Designed an d Certified for Compliance with the International Bui lding Code & ASCE/SE I-7 .
Water Seal Rati ngs
W ater Sea ling Tested to UL 441 Section 27 "Rain Te s t" and TAS 100-95 "Wind Dr iven Ra in Test" by lntertek .
Ratings applicab le for composition shi ngle roofs having slopes between 2 :12 and 12 :12.
UL2703
Conforms to UL 2703 Mechanical and Bondin g Requirements . Se e Flush Mou nt In stall Manual for full ratings .
f I 0 • 1 0
3
t )ESIGN & DRAFTIN G BY:
DANA HAJEDEMOS
3CEP : PV-100414-010500
R
OESCRIP nON DAlE REV
ORIGINAL 1/15/2019 A
G reen light
SOLAR SYSTEMS
PROJECT NAME
SHEET N AM E
MOUNTING
DETA IL
SHEET SIZE
11"x 17"
SHEET NUMBER
P V-3.1
~IRONRIDGE
Attn: David F. T aggart, VP Products, lronRidge Inc.
Date: September 30"'. 2016
Re: Structural Certification for the lronRidge FlashFoot2
1
1495 Zephyr Avenue
Hayward, CA 94!>44
1-800·227 -9523
lronRidge.com
This letter addresses the structural capacity o f the l ronRidge FlashFoot2 (FF2) component for use as a roof attach ment for PV solar
systems. FF2 Is composed of an aluminum Cap, a 9" x 12" aluminum flashing, and an aluminum stabilizing base. The flashing
component is attached to an underlying roof rafter using a 5/16" lag bolt. The assembly details are shown in Exhibit EX-0013.
The referenced uplift and lateral resistance of FF2 is based on structural tests conforming to ASTM 01761-12 "Standard Test Methods
for Mechanical Fasteners i11 Wood: Testing was performed by installing a FF2 component on a sample roof deck composed of
composition shingles covering Y. • OSB Board over a 2x4 Dougla s Fir rafter as shown in Figure 1. The moisture content and specific
gravity of the rafter was measured and recorded per ASTM 0 2395·14 "Standard Test Methods for Density and Speci fiC Gravity
(Relative Gravity} of Wood and Wood-Based Materials." The moisture content for uplift test samples was between 8% and 15% w ith an
average specific gravity of 0.54. The moisture content for lateral test sam pl es was 13% with an average specific gravity of 0.54 .
The critical failure mode observed for both the uplift and lateral tests was pullout of the 5/16" lag screw from the rafter. The average
peak loads recorded at the critical fa ilure point for the uplift and lateral tests were 3203 lbs. and 1237 lbs., respectively. A safety
factor of 3.0 was applied to certify the allowable uplift capacity to 1067 l bs. and the allowable lateral capacity to 412 lbs. for a
substrate with a specific g ravity of 0 .54.
For rafter wood species with specific gravity other than 0.54, the allowable uplift capacity shall be adjusted by a factor of (...E...)i per
054
AP&PA National Design Specification Eq. (12.2·1), and the allowable lateral capacities shall be adjusted per the equation I -(0.5-G)
from APA Engineering Wood Construction Guide APA 2011 (G is wood specific gravity). For the common wood species, the allowable
capacities are provided in Table 1.
Wood Species
Douglas Fir, larch
Douglas Fir, South
Hem. Fir
Hem, Fir (North)
Southern Pine
Soruce, Pine, Fir
( J} The minimum siu rafter is ZX4.
Table 1 . Iron Ridge FlashFoot 2 Allowable Capacit ies Ill
NOS Assigned Speci fic
Gravitylll
0.50
0 .46
0.43
0 .46
0.55
0.42
Allowable Uplift Capacity
(lbs)U I
9S1
839
7S8
839
1097
732
(2) The listed specific gravities ore per 20JS NOS Tab le J1.3.3A.
Allowable lat eral Capa cit y
(lbs)lll
396
380
368
380
416
364
(3) Values ore based on securing log bolt within cen ter J/3 of rafter w idth with o minimum 2.5' end distance, and loading di rections os shown In
Figure J .
late ral Uphh
EXHIBIT: EX-0013
( 12.0in ) ~ --
I ---e
~4.5i n}--
1------~ 9.0in \------"'
'= =
STABiliZIN G SASE
FlashFool2 Cop c o n be installed in ell her orie n tation shown
ITEM NO. DES CR IPT ION
ASSY , FLASH ING. M IL L OR BLACK
Cl 20 16 lronRidgo, Inc.
2 ASSY, CAP. MILL OR BLACK
IRON RIDGE
-"'""'"''''\ Flashfoot2Cerl!fiCaHon le11er·1 3 BOLTLAG5/16X4.75" ---;~OF rE \\\ ASSY . FLASHFOOT 2 ;' ~'t-. .............. ..(..t \• 4 WASHER . EPDM BACKED
,_ f? ,••' '•;'Jf$' '• -------,-----------------L~====~===========;:::=================O=W:G:·:N:O:. :::E:X·:OO:I:J====.J ·-:-.-::-·---·---·-... -.-·~,--, * : · .• , .... ~ ...................... : .... ~
f. ROGER LEWIS BLAI R 1. '-~. ................................ ~ • • tl ,,~ ... 11056 4 .:,._,
~·· ··~; t, O~··.~!CENS~~.··~~ ,.:' ~~~ ·N:Q b~r 16 ,2019
Texas Firm No. F-15209
u• IRONRIDGE
1
1495 Zephyr Avenue
Hayward, CA 94544
1·800·227-9523
lronRtdge com
t JESIGN & DR AFTING BY:
DANA HAJEDEM OS
3CEP: PV-100414-010500
RE Vl S IONS
OESCRJP noN OA 1( REV
ORIGINAL 1/15/2019 A
€)
G reen light
SOLAR SYS T EMS
PRO JECT NAME
SHEET NAME
MO UNTING
DE TAIL
SHEET SIZE
11 "x17 "
SHEET NUMBER
PV-3.2
305 -31 5 W
CLASS LEADI NG POWER OUTPU T
1 8 .9 5 %
MAXI MUM EFF I CI ENCY
POSITI V E POWER TOLERANCE
High -Power , Ame r ica n Qua lity
MiS>ion Solar Energy is headquartered in San Antonio, TX with module
facilities onslte. We produce American quality product s ensuring the
highest power output and reliabi lity t o our cus t o mers. Our product line
is well suited l or reslden~al, commercial and utili ty applications. Every
M ission Solar Energy product is certified and surpasses Indu stry
stand ard regulations. proving excellent perf ormance over the long·term.
www.mlsslonsolar.co m I info@mfsslonsolar.com
CERTI FIED RELIAB I LITY
• Tested to 3X IEC Standards
• PID Resistant
ADV A N CED TEC H NOLOGY
• PERC and 5 busbar dri ve > 18% module efficiency
• Id ea l for residential & co mm ercia l appl ications
EXT REME WEATHER RESILIENCE
• 5600 Pa snow load (117 psf}
• 175 mph wind rating
~ BAA COMPLIANT FOR GOVERNMENT PROJECTS
• Buy American Ac t
• American Re covery & Re investment Act
e e
LINEAR WARRANTY PRODUCT WARRA NTY
5 10 15 20
YEARS
CER T I FICATI ONS
IEC 61215/ I EC61730/ I EC 61701 UL 1703
Iii.'\ ,§)
c'-Yus Po~tGuord CEC
us no ·
'A5 there: kc diHCfl:'nt ccrtl flu rion rcqoitcmcnts tn diffcr~nt m.ukds. plc.nc cont.ct Y'OUf local
Min ion Solar Enc~sv sales rcprcW!nt ativc for the spe<iflc ccrtlfkatcs o1pplkab&c to 1 ~ produc ts in
the rcgton in whkh the produc u are to be U5<d.
J!a~· ~·~
MISSI ON SDL/\R ., 1
E N ERGY • '
25
PERC 60
ELECTRICAl SPEC IFICATIONS
Elc<ttlu l Par~mettrs at St.,ndard Test Conditions {STC)
Module Type M SE305SQ8K MSE310SQ8K
Power Output Pmax Wp 305 310
Module Efficiency " 18 .35 18.6S
Tolerance 0 '+3% 0 '+3%
Short-Circuit Current l sc A
Open Circuit Voltage Voc v
Rated Current Imp A
Rated Voltage Vm p v
Fuse Ra~ng
TEMPERATURE COEFFICIENTS
Normal Operating Cell Temperat ure {NOCT)
Temperature Coefficient of Pmax
Temperature Coefficient of Voc
Temper ature Coefficient of lsc
OPERATING CONDITIONS
1,000VDC
9 .723
39.96
9 .238
33.02
20
44•c (t2•c)
-0.427%/"C
·0.318%/"C
0 .042'lWC
9.819
40.09
9.362
33.11
20
Maximum System Voltage
Operating Temperature Range
Maximum Series Fuse Rati ng
Fi re Safety Classification
-40'C (·40°F) to +9o•c (194°F)
20A
Front & Back Load (U L standard)
Hall Safety Impact Velocity
Type 1. Class C
5600 Pa {117 psi)
25mm at 23 m /s
MECHANICAL DATA
Solar Cells
Ce ll orientation
P-lype M ono-crystalline Silicon {156 .75m m)
60 cell s {6x 10), 5 busbar
1664mm x 999mm x 40mm
l65.51in. x 39.33 in. x 1.57 in.) Module dimension
Weight
Front Glass
Frame
Encapsu lant
J·Box
Cables
Connector
18.2 kg (40.11b)
3.2mm (0.126 ln.) t empered,
Low-iron, Anti -renective coating
Anodi zed aluminum alloy
Ethylene v inyl ace tate {EVA)
Protection class IP67 w ith 3 bypass-diodes
PVwlre, 1m (39.37 in.). 4mm' I 12 AWG
MC4 or compatible
SHIPPING INFORMATION
Contai ner FT Pallets Panels 305W
53' Double stack 36 936 285.48 kW
40' Double st ack 28 728 222 .04 kW
Panels Weight He ight Widt h
Pallet 26 1.1601bs 45.15' 45.00'
Length
66.00
CLASS LEADING 305-31SW
CERTIFICATIONS & TESTS
MSE31SSQ8K IEC
3 1 5
18.95
0'+3%
9.917
40.13
9.465
33.2 8
20
"
61215 /61730 /61701. Salt mist
UL
UL 170 31istcd
( ~) w e@ us J,
'owetGuCHd CEC usno
MSE315SQ8K: 315WP, 60CELL SOLAR MODULE
CURRENT ·VOLTAGE CURVE
Incident lrrd.al ,OOO W/m
10 -----------'---........
Inciden t hr d.a8()()
5:
lncldC!nt hrd,s600
Inciden t 1H d .:400
~ . ---------------~
lnddenl lud.:200
~ " IJJ .,
VolugeiVJ
Currc nt•voltage characteris tics with dependence on lrradiancc
and module temperatu re
BASI C DESIGN (UN ITS: mm)
..
Fron t Vi ew
,.
'• "'"" -r;;51 r
I
~--
I-• Grounding -
/.
.....
Back View
. ·--:
. .~
~\·
MISSION SOL/\; .,
ENER GY .• '
Mission Sol•t [netcv 1 8~03 S New Braunfels A11C! , S~n Anlonlo, T~~~~ 78235
lnfo$tni ~~ionsol.u com I www miulonsolo~r com
DESIGN & DRAFTI NG BY:
DANA HAJEDE MOS
NABCEP : PV-100414-010500
ORIGIN ... L 1/15/2019 A
8
G ree nlight
S OLA R SY S TEMS
PROJECT NAME
SHEET NAME
EQU IPM EN T
SPEC IFI CAT I ON
SHEETS
SHEET SIZE
11 "x17 "
SHEET NUMBER
P V -4
r 111 1
Enphase Microi nve rt ers
Prq.~'" AMI PICAS
En phase
IQ 7 and IQ 7+
Microinverters
To l earn more abou t En phase offering s. vis it enphase.com
Th e hig h-powered sma rt grid-ready
Enphase IQ 7 M i cro '" and Enphase IQ 7+ Micro··
dram atica lly simpl ify th e ins tallati on process wh ile
achiev in g the highes t system eff1ciency.
Part of the Enp hase 10 Syst em. t he 10 7 an d
10 7+ Microinvert ers integ rate w ith the Enphase
10 Envo yN, Enph ase 10 Battery'". and th e Enp hase
Enligh ten'" moni tori ng and analysis software .
10 Seri es Microinver ters ex tend t he rel iability
standards set for th by prev io us g enera tions and
unde rgo over a mi ll ion hours o f power-on testi ng,
enab lin g Enpha se to prov ide an ind ust ry-lead ing
warranty o f up to 25 yea rs.
Easy to Install
Ligh t weigh t and si mple
Fas ter i n st alla t ion w ith improved, l ight er t wo -w ire cabling
Built-in rapid s hutdow n c omplian t (NEC 2014 & 2017)
Prod ucti ve and Reliable
• Opti mize d for h igh p ow e1ed 60·cell and 72-cell' modu les
M01e than a million h ou rs of t est in g
Class II d o u b le-insu lated enclosure
UL li sted
Smart Grid Ready
Complies with advan ced grid s u ppor t. voltage and
fr e que ncy rid e·l hrough requi re m ents
Rem o tely updat es t o resp ond to c h angi ng
g rid requirement s
Conf1gu rable for varyi ng gnd profiles
Meets CA Ru le 21 (U L 1741·SA)
·The IQ 7 • ~hero 1s requtred 10 suppon12-cell modules
9 ENPHAS E
Enphase IQ 7 and IQ 7+ Microinverters
I NPUT DATA (DC) 10 7·60 ·2-US /107·60·0 -US 107PL US·72·2·US /IQ7PLUS ·72·B ·US
'COmmonly used modu le pairings'
M odul e com patibihty
~-350W+ --2-35 w. 440 w +
M aximum inp ut DC voltage
Pe ak power t racking vo l tage
Operating range
Mi n/Max st art voltage
Max DC sho rt c irc uit c urrent (module lsc)
Over voltage class DC port
DC p or t back feed current
PV array confi guration
OUTPUT DATA (AC)
Peak o ut put power
M axim um c ontin uous o utput power
Nominal (L·L) voltage/range'
Maximum co ntinuou s o utput c urrent
Nominal frequency
Ex tended freque nc y r ange
AC s hort circuit fault current ove r 3 cycl es
Maximum un its p er 20 A (L·l ) branch c i rcUJI'
Overvoltage class AC p or t
AC p ort back feed current
Power f ac tor se lling
Power f ac tor (adjustable)
EFFI CI ENCY
Pea k eff1ciency
CEC weigh ted efficien c y
MECHANICAL DATA
Ambient t emperat ure r a n ge
Rel at ive humidi ty range
Conn ector type (107·60·2-US & IQ7PLU S·72·2·US)
Connec tor type (IQ7·60·B·US & 107PLUS·72·B·US)
Di m ensions (Wx HxD)
Wei ght
Cooling
App roved for w et locat ion s
Pollu t ion d egree
Enclosure
Environmen tal category 1 UV exposure rat ing
FEATUR ES
Com municati on
Monitorin g
Di sconnectin g means
Comp lian ce
6 0·cell PV modules onl y
4 8V
27 V · 37V
16V·4 8V
22 v /48 v
15A
II
O A
60·cell and 72·cell PV modules
60 v
27V·4 5V
16 V ·60V
22 v /60 v
15A
II
OA
1 x 1 ungrounded array; No addit ional DC side prot ection required;
AC side prot ection reqUJres max 20A per branch c11cu it
IQ 7 M lcroi nvert er IQ 7+ Mlcrolnverler
2 50VA 295VA
2 40VA 290VA
24 0 V I 208V I 240V I 208V I
211 ·264 v 183·229 V 21 1·264 v 183·229 V
1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V)
60Hz 60 Hz
4 7 ·68Hz 47-68Hz
5.8 Arms 5.8Arms
16 (240VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC)
Ill Ill
O A OA
1.0 1.0
0.85 leading ... 0.85 laggin g 0.85 leading ... 0 .85 lag ging
@2 4 0 v @208 v @240 v @208 v
97.6% 97.6% ~ 97.3% ___
97.0 % 97.0% 97.0 % 97.0 %
-4o•c to +65°C
4% to 100% (condensing)
MC4 (or Amphenol H4 UT X wit h additional O·DCC-5 adapter)
Friends PV2 (M C4 intermateable).
Adaptors for modules with MC4 or UTX connectors.
• P V2 to M C4: order ECA·S20·S22
· P V2 to UTX: order ECA·S20·S25
212 mm x 175 mm x 30.2 mm (wit hou t bracket )
1.08 kg (2.381bs)
Natural convec tion· No fans
Yes
PD3
Class II double-insulated, corrosion resistant polyme11c encl osure
NEMA Type 6 / outdoor
PowerUne Communication (PLC)
Enhghten Manager and MyEn li ghten momtormg options.
Both options require Installation of an Enphase IQ Envoy.
The AC and DC connect ors have been eval uated and app1oved by UL for use as the load-break
disconnect required by NEC 690.
CA Ru le 21 (UL 1741-SA)
UL 621 09·1, Ul1741/IEEE1547, FCC Part 15 Class B. ICES-0 003 Class B.
CAN /CSA·C22 2 NO 107.1-01
This product is UL listed as PV Rapid Shut Down EqUipment and conforms vmh NEC-2014 and
NEC -20 17 sec11on 690.12 and C22.1·2015 Rule 64·218 Rapid Shutdown of PV Systems. for AC
and DC conductors, when 1nstalled accord1ng manufac t urer's mstrucllons
1 No enforced OC/AC ra110. See the compattb•hty calculato1 at hli~.JlJ:.[Ulbose.c.o.r:nltn.:u..$/llP.PW..llmwluli:.:t.CUDDAltiUltW
2 . Nom mal vo ltage range can b e extended beyond nominal •f rcqutrcd by !he ut•l•ty
3 Llm•ls may vary. Refer to local rcqUircmcnls to dcf me the number of nHcrotnvcners per br anch m your arc3
To lea rn mor e abou t Enphase offerings, vi sit enp hase.com
2018 Er pl·a :~~ (ntrg,-.'\' t:r;t·t ,. '( .t t •.:·l AIIUat't.m..t•!.:s vr l:r ,,n,•· o d ... , •h~;~ 11' l·•tv vf fn~11dSe fn.:rgy tn(
20t8 ttlg
9 ENPH ASE
DESI GN & DRAFTING BY:
DAN A HAJEDE MOS
NABCEP : PV-1004 14-D10500
R
DESCRIPn ON RE V
ORIGINAL 1/15/201 9 A
CD
G reen light
SOLAR SYSTEMS
PROJEC T N AM E
SHEET NAME
EQU IPMENT
SPE CIFICA TION
SHEETS
SHEET SIZE
1 1"x 1 7 "
SHEET NUMBER
PV-5
Di.lta Sheet
Enphase Networking
En phase
IQ Combiner
(X-IQ-AM1 -240-B)
®
LISTED
To l earn more about En phase off er ings, vi si t enphase.co m
The Enp hase IQ Combi ner '" wit h Enphase IQ Envoy '"
consolidates int erconnec tion equipment into a
single enclosure and strea m li nes PV installa tions by
prov iding a consis ten t. pre -wired so lu tion for resident ial
applications.
Smart
Includes IQ Envoy for communication
and con t rol
Fl exi b le n etworking suppor t s Wi·Fi,
Ethernet , or cell ular
Si mple
• Three pre-installed 20 A I 2 40 VAC
ci r c uit breaker s
Provides production m e te ri ng and optional
consumpt ion monitoring.
Reliab le
Durable NRTL·certif1ed NEM A type
3 R enclosure
Five-year warranty
9 ENPHASE
Enphase IQ Combiner
MOD EL NUMBER
IQ Comb ine r X·IQ·AM 1·240·B
ACCESSORIES (order separately)
Enphase M obile Connect ~
CELLMODEM ·03 (4G /12·year data pl;m)
CELLMODEM ·01 (3G I 5-year data plan)
Consumpt ion Mo ni toring CT
CT·2 00·SPUT
EL ECTR IC AL S P ECI FICATION S
Rating
Solar branch circ uit br eakers
Maximum sy stem voltage
Rated output cu rrent
Rated Input current, eac h input
Maximum fuse/circuit breaker rating (ou tput)
Production Metering CT
MECHANICAL DATA
Dimensions (WxHxD)
We ig ht
Ambient t emperature range
Cooling
Enclosure envi ronmental rating
Wire size
Altitude
INTERNET CO NNECTION OPTIONS
Integrated Wi·Fi
Ethernet
Cellular
COMPLIANCE
Compliance, Combi ne r
Compliance. IQ Envoy
IQ Combiner with En ph as e IQ Env o y·· for in tegr ated revenue grade PV production me tering
(A NS I C 12.20 +/· 0.5%) and optional consumption monitoring(+/· 2.5%).
Plug and play industrial grade cellular modem wi th data plan for systems up to 60
microlnver ters . (Ava i lable in the US, Canada. M exico, Puer to Rico. and the US Vi rgin Islands.
where there Is adequate cellu lar service In the Installation area.)
Sp lit core current transformers enable whole home consu mption metering(+/· 2.5 %).
Continuous duty
Three 2-pole 20 A/240 VAC DIN rail-mounted breake rs
240 VAC
4 8A
16A
60A
200 A solid core pre· installed and w ired to IQ Envoy
38.0 X 38.7 X 20.3 em (15.0" X 15.3" X 8.0 ")
5.1 kg (1 1.2 1bs)
·40° C to +46° C (·40° to 115° F)
Ven ted, natur al convection, plus hea t shield
Outdoor, NRTL·certif1ed, NEMA type 3R, polycarbonate construction
14 to 6 AWG copper con ductors for branch in puts.
14 to 4 AWG copper con ductors for combined output.
Follow local code requirements for conductor si zing.
To 2000 me ters (6 ,560 fee l )
---------------
802.11b/g/n
802.3, Cat5E (or Cat 6) UTP Ethernet cable· not in cl ud ed
Optional, CELLMODEM ·Ol (3G) or CELLMODEM·03 (4G) ·not Incl uded
UL 174 1
UL 916
CA N/CSA C22.2 No. 61010·1
47 CFR. Pa r t 15. Cl ass B. ICES 003
IEC /EN 61010·1:2010,
EN50065·1 . EN61000·4·5, EN61000·6·1. EN6100 0·6·2
Meteri ng : ANS I C12 .20 ac c ura cy class 0.5
To lear n more about Enphase offerings, v isit enp hase.com
2017 l nphase lnergy AI ughts rctC'rved All lladernarks or b1ar,tl:i tn t h1~ docUinC'nt d ll· u .. •g 1~h;rt:d Ut the.r respect1v~ O\\ner
20 17·08 17 9 ENPHASE.
DAN A HAJEDEMOS
llCEP: PV-1004 t 4 -010500 t lESIGN & DRAFTING BY:
DESCRIPTI ON
ORIGINA L t /t 5/2019 A
8
G reen light
SOL /\R SYSTEMS
PROJECT NAME
SHEE T NAME
EQUIPME NT
SPEC IFICATION
SHE ETS
SHEET SIZE
11"x 1 7 "
SHEET NUMBER
P V-6
PHOTOVOLTAIC ELECTRICA L DIAGRAM
CABLE SCHEDULE AND CALC5
CIRCUIT CONDUCTOR CONDUCTOR CONDUCTOR LONGEST CONDUCTOR GROUND GII-OUND GROUND CONDUIT CONDUIT FILL SERVICE QTY INSULATION I.D. # SIZE AMPACITY MATERI AL LENGTH(FT) (90'CJ SIZE QUANTITY INSULATION TYFE DE RATE
I AC 3 AWG #1 2 30 cu 70 0-CABLE AWG #8 I BARE FREE AIR I OREMT
2 AC 4; 2 AWG #10 40 cu 40 THWN -2 AWG #8 I THWN-2 EMT 0 .8
3 AC 3 AWG #G 75 cu 10 THWN-2 AWG #8 I TH WN-2 EMT I
GENERAL NOTES :
1. INSTALLATION SHALL BE AC CORDING TO THE NATIONAL ELECTRIC CODE 2017 AND ALL STATE AND LOCAL STANDARDS
AND CODES .
2. INSTALL LABELS ON ALL ENCLOSURES, INVERTERS, SWITCHES , LOAD CENTERS AS PER NEC .
3 . AC DI SC ONNECT SHALL BE EXTERNALLY OPERATED KNIFE BLADE TYPE AND LO CKABLE IN BOTH ON AND OFF POSITIONS,
AND DIRECTLY ACCESSIBLE TO UTILI TY.
4 . ALL ELECTRICAL WORK WIL L COMPLY AND BE INSPECTED BY A LICENSED MASTER ELECTRICIAN AND ALL LOCAL CODE
AUTHORITIES .
5 . CONTRACTOR IS RE SPON SIBLE FOR ENSURING INSTALLATION IS PER NEC & MANUFACTURER'S DESI GN SPE C.
6 . ALL CONDUCTORS SHALL BE COPPER , RATED FOR 600V AND 90'C, AND RUN IN CONDUI T.
7 . CONTINUOUS GROUND IS REQUIRED. IRREVER SIBLE COMPRESSION CLAMP S REQUIRED FOR ALL GROUND SPLICES.
8 . MICROINVERTERS COMPLY WITH RAPID SHUTDOWN PER 2017 NEC . RAPID SHUTDOWN SIGNAGE SHALL BE INSTALLED PER
NEC 2017 , SEE SHEET E-2 .
TRAN SITION BOX -ROOF 1
AGGR EGATE PANEL
125A ~AIN LUC ONLY
NEMA JR, UL USTED
(2) 20 A 2-POLE BREAK ER S
AC DISCONNECt
240 VAC, 60 A
NEMA JR. UL LISTED
(2) 60 A FUSES
IIISIBL£. LOCK ABLE , LABELED.
\\!tHIN 10' Or METER
CONDUIT TEM P
SIZE DERATE
N/A 0.7 1
3/4" 0.71
3/4 ' 0.9 1
TO UTILI TY GRI D
DERATED
AM PACITY
28.4A
22.72A
G8.25A
BI-DIRECTIONAL
UTI LIT Y ME TER
1-PH ASE, 240 V
MAX CIRCUIT
CURRENT
IGA
I GA
4 5A
MAIN SERVICE PANE L
CE LOAD CENTER
I-PH. 3-W
240 VAC
200A BUS, 200A MAIN BREAKER
SU PPLY SIDE INTERCONNECTION
G -~ '---'l I
.A ........
Bronch Circuit 2 :
.------, Roof 1 (7) & Roof 2 .-----~ ~----, .------,
(16) 310W MODULES
(16 ) ENPHASE 107
...........
===@--l
I
I
I
I
Bronch Circuit 3:
Roor 3
(13) 31 0W MODULES
(13) ENPHASE 107
20 A
I L...::=j~~~ l
I I I EXISnNG GROUNDI NG
L - ---_j I ELEC TRODE SYS TE M
_j__
t >ESIGN & DRAFnNG BY:
DANA HAJEO EMOS
lCEP: PV-100414 -010500
OESCRIPnON
ORI GINAL 1/15/2019 A
@}
G reen light
SOLAR SYSTEM S
PR OJECT NAME
SHEET NAME
ELECTRICAL
DI AGRAM
SHEET SI ZE
11"x 17"
SHEET NUMBER
E -1
PV SYSTEM AC DISCONNECT
RATED AC OUTPUT CURRENT: 45 A
NOMINAL OPERATING AC VOLTAGE : 240 V
~R~E~Q...!:'D:.....B~Y!.'-.: ....:N~E~C....:6"-"9~0'-"'.5-'-4 ---~
APPLY TO:
PV AC DI SCONNEC T
THIS PREMISE IS SUPPLIED BY MORE
THAN ONE SOURCE OF ELECTRIC POWER
(UTILITY, SOLAR PV)
REQ 'D BY: NE C 705.10 f"2l
MAIN SERVICE PANEL ~
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS OVERCURRENT DEVICE .
~RE~O<!....!'DLJ2B:..!.;Y:'--...!.::!.NE~C-!........!..:.70~5~.1~2_](~BA)(..=.2 )LI..( 3:,!.J.)~(bu..) -~[2]
INTE RCONNE CTION BREAKER
INVERTER OUTPUT CIRCUIT CON NECTION S IN AG G PAN EL
WARNING
THIS EQUIPMENT FED BY MULTIPLE SOURCES.
TOTAL RATING OF ALL OVERCURRENT DEVICES,
EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE ,
SHALL NOT EXCEED AMPACITY OF BUSBAR
~Rf.!EO-:L.'D!LEB~Y~: .!::!N.s.!EC~7:::!:05-!.:....1~2,....:(1..EB~)(..=.21..l.)(~3 )u..:( c-:..1.) __ 0
P OI NT OF INTER CO NNECTION
(MAIN SER VICE PANEL)
WARNING-ELECTRIC SHOCK HAZARD
TERMINALS ON BOTH LINE AND LOAD SIDES
MAY BE ENERGIZED IN THE OPEN POSITION
DC VOLTAGE IS ALWAYS PRESENT
WHEN SOLAR MODULES ARE
EXPOSED TO SUNLIGHT
REQ ' BY : 690.13(B) AND 690.15
APPLY TO:
DIS CO NN ECTS
WARNING
THIS DISCONNECTION OF THE
GROUNDED CONDUCTORS MAY
RESULT IN OVERVOL TAGE
ON THE EQUIPMENT
RE Q'D BY: NE C 690 3 1(1)
APPL Y TO: N/A
BIPOL AR PV SYSTEM
PV SYSTEM DC DISCONNECT
MAXIMUM VOLTAGE : NA V DC
MAXIMUM CIRCUIT CURRENT: NA ADC
MAX RATED OUTPUT CURRENT OF THE CHARGE
CONTROLLER OR DC TO DC CONVERTER: NA A
~R~E~o·~o....:B~Y~:~N~E~C ~6~9~0.~53~--GJ
APPLY TO:
INVERTER IN TEGRATED DC DISCONNECT
WARNING-ELECTRIC SHOCK-HAZARD
(
TERMINALS ON BOTH LINE AND LOAD SIDES
MAY BE ENERGIZED IN THE OPEN POSiriON
...!R~E~Q_' !:!..BY.!..:.:-.:6~9~0.:..!..1!!..3 ----~
APPLY TO:
AC DISCONNEC T
RAPID SHUTDOWN PV ARRAY
~R~E~O_'~BY~:~6~9~0.~1,2~(~B)~(2~)----~
APPLY TO:
SOLAR CONDU IT IN SIDE ARRAY BOUNDAR Y
I WARNING-PHOTOVOL TAlC POWER SOURCE I
REO' BY: 690.3 1 (G)(3) G
APPLY TO:
SOLAR CONDU IT
I WARNING-DO NOT DISCONNECT UNDER LOAD I
REO ' BY: 690.15(C) G
APPLY TO:
REVENUE METER
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
REO' B Y: NE C 690.56(C)(3) ~
APPLY TO :
P V AC DISCONNECT
. ~~-------------------------------. !
PHOTOVOL TAlC SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TU RN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN ARRAY
...!Rl.!:E~O_' ~BY.!..:.:....:N~E~C....:6~9~0:..:=. 5~6(~C:.Lll(..:...1 )""( o"-'2--GJ
BL ACK ON YELLOW BACKGROU ND
AP PLY TO: PV AC DISCONNECT
~;NAGE REOUIREMEN TS
> RED BACKGROUND
> WHITE LETTERING
> MIN . 3/8" LETT ER HEI GHT
> ALL CAP IT AL LETTER S
> ARIAL OR SI MILAR FONT
> REFLE CTIVE, WEATHER RES ISTA NT
MATE RIAL, UL 969
-
DAN A HAJEDEM OS
BCEP: PV-100414-010500 t )E SIGN & DRAF TI NG BY:
11E_VI S!ONS
DESCRIPnON DATE REV
ORIGINAL 1/15/2019 A
'tD
G reen light
SOLAR SYS TEM S
PROJECT NAME
W N
w >m
ucr::o zo<D w I"-
oo --ox
(f) O f-w
0:: 3: -
(f)W
o._C)::::S:::
2Z<(
<(::::.::::_]
u ~
w~:::::> o~o
~(f)
J
SHEE T NAME
SYSTEM
LABE LI N G
DETA IL
SHEET SIZ E
11"x 1 7"
SHEET NUMBER
E-2