Loading...
Item 9 - PlansSYSTEM RAT ING ROOF-1 7 .130 kW DC STC ROOF-2 2 . 790 kW DC STC ROO F-3 4 .030 kW DC S TC TOTAL: 13 .950 kW DC STC EQUI PM EN T SU MMA RY 4 5 MI SSION SOLAR 31 0 -W MODULES 45 ENPHASE 107 MICRO INVERTERS SHEET INDEX PV-1 COVER PV-2 SI TE PL AN S-1 ROOF 1 S-2 ROOF 2 S-3 ROO F 3 PV-3 MOUN TING DETA IL PV-3.1 MOU NTIN G DET AIL PV-3.2 MOU NTIN G DET AI L PV-4 SPEC SHEET S PV-5 SPEC SHEE TS PV-6 SPEC SHEETS E-1 ELECTRICAL DIAGRA M E-2 SIGNAGE GOVERN ING COD ES 2017 NA TI ON AL ELEC TRICA L CODE UND ER WRITERS LABORATORIES (UL) STANDARDS 1741 FOR INVER TERS, 1703 FOR MODULES 201 5 IRC IN TERNATIO NAL RES IDEN TI A L CODE AER IA L VIEW DESIGN & DRAFTING B Y: DANA HAJEOEMOS NABCEP: PV-100 414-010 500 OESCRIPnON OA TE RE V ORIGINAL 1/15/2019 A G reen Light SOL AR SYSTEMS PROJECT NAME SHEET NAME SHEET S IZE 11"x1 7" SHEET NUMBER P V -1 Ll .d' <1.d SITE PLAN .<1 <i <1 Ll .· .d .Ll .. ~ .<1 <1 <1 .d ·Ll <1 .d . .d <1 <1. Ll .d <1.d . .d ( 45) MISSION SOLAR 31 0-W MODULES TOTAL, 13.950 kW DC STC .L} .d <1 t--+--+---1 <1~ D ( 45) EN PHASE ENERGY INC. 107-60-x-US (240V) MICROINVERTERS, TOTAL 10.800 kW AC SINGLE STORY ACCESS FLUSH MOUNTED ROOF ARRAYS: COMP SHINGLE ROOFING ROOF /ARRAY #1 -23"Pitch , 270'Azimuth -(19) MODULES ROOF /ARRAY #2 -34'Pitch, 90'Azimuth -(8) MODULES ROOF /ARRAY #3 -34'Pitch, 180'Az i muth -(18) MODULES DRAWING SCALE: 3/32"=1'-0" AGGREGATE PANEL V AC DISCONNECT TILITY METER 0 0 0 DISTRIBUTION PANEL s 0 0 l D DESIGN & DRAFTING BY: DANA HAJEDEMOS NABCEP: PV-1 00414-010500 REVISIONS DESCRIPTION DATE REV ORIGINAL 1/15/2019 A REVISION 1/2/2020 G reen light SOLAR SYSTEMS PROJECT NAME SHEET NAME SITE MAP SHEET SIZE SHEET NUMBER PV-2 /40 IRONRIDGE Sol ar Is Not Always Sunny O ver the ir lifetim e, solar p anels experience co u ntl ess extrem e weather event s. Not j ust t he worst storms in yea rs, bu t t he worst st orm s in 40 years. High winds capable of r ipping pa nels from a roof, and snowfall s weig hi ng eno ugh to buckle a p an el frame . XR Ra ils are the s tructu ral backbo ne preven t ing th ese resu lts. They resist u p lift , p rotec t against bu cklin g and safe ly and effic iently tr a ns fer loads into the b u ilding stru cture. T heir su pe ri or spanning capabi lity requires fewer roof attachments, reducing the number of roof penetrat ion s an d the amou nt of insta ll ation t ime. Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twi st . The curved shape of XR Rails Is specially designed to increase strength In both directions while r esisting the twisting. This unique feat ure ensures greater secu rity during extreme weather and a longer system lifet ime. XR Rail Family _, ............. ,,, I ----~OFT \\ l: ~ '\~~ .......... ff:t: \\ IJ ~ ~ .... * '1d' ., *'~·: ..• 1, , • : ·. * , .... ~ ...................... : .... ~ '-ROGER LEWIS BLAIR I ~································.,! ,,-<J .... 110564 /,..,1 '1 ~·· •'9J ' t, O~··.~(CENS~~···~«<_:" \ ~$. ''"~~ I ~~- No er 16,2019 Texas Firm No. F-15209 Compatible with Flat & Pitched Roofs C orrosio n-Resis t ant M a teri al s 11 XR Rails are rl lronRidge offers compatible w ith ~ ~ a range of tilt leg FlashFoot and liJ options for fla t other pitc hed roof I roof mounting allachments. apphcahons. All XR Rails are made ot marine-grade aluminum alloy, then protect ed wi th an anodized finish. Anodizing prevents su rface and structural corrosion, whil e also providing a m ore attracti ve appearance. XR Ra i l Family The XR Rail Family offers the strength of a curved ra il in three targeted si zes. Each size su pports specif ic design loads, whi le m inimiz ing material costs. Depend ing on you r location , there is an X R Rai l to match. XR10 X R 1 0 is a sleek, tow-profil e mounting ra il, desig ned for regi o ns with light or no snow. It achieves 6 foot spans, white remaining tight and economical. 6' spannin g capabili ty Moderate load capability C lear anodized finish Internal splices available Rail Selection XR100 XR 1 00 Is the ultimate residential mounting rail. II supports a range of w ind and snow condit ions. wh ite also maximizing spans up to 8 feet. 8' spanning capability Heavy toad capability C lear & black anodized tinish Internal splices available XR1000 XR 1000 is a heavyweight among so lar mounting rails. It 's built to hand le extreme climates and spans 12 feet o r more for commercial applications. 12' spanning capability Extreme toad capability C lear anodized finish Internal splices available The following tabl e was prepared in compl ian ce wit h applicable engi ne eri ng codes and standards. Values are based on the following crite ria : ASCE 7-10, Roof Zone 1, Exposu re B , Ro of S lope of 7 to 27 degrees and Mean Building Height of 30ft. Vis it lronR id ge .com for detailed span tables and certifications. Load . : 100 120 None 140 XR10 XR100 XR1000 160 100 120 10-20 140 160 100 30 160 100 40 160 50-70 160 80-90 160 DANA HAJEDE t.i OS t)ESIGN & DRAFTING BY: 3CEP : PV-100414-0105 00 R OESCRIPnON REV ORIGINAL 1/15/2019 A G reen light SOL/\R SYSTEMS PROJECT NAME SHEET NAM E MOUNTI NG DETA IL SHEE T SIZE 11 "x17" SHEET NUMBER PV -3 d¢ IRONRIDGE The Strongest Attachment in So l ar lronRidge FlashFoot2 raises the bar in solar roof protection. Th e unique water seal design is bot h elevated and encapsulat ed , deliverin g red un dant laye rs of protection against water intrusion. In addition , the twi st-on Cap perfectly aligns the rail attachment wi th the lag bo lt to maximize mech an ical strength . Twist -On Cap FlashFoo12's u nique Cap design encapsulates the lag boll and locks into place with a simple twist. The Cap helps Flash Foot2 deliver superior stru ctu ral strength, by aligning the rail and lag boll in a concentric load path. _ ......... ,,,,, ---~OF r,. \\ -A.~~ ........ ,c;.; \\ ;' C:>~···''*''•4U' '1 , . . ' ,.... ....,, ,.: ~. , .... ~ ...................... : .... ~ I ROGER LEWIS BLA IR I ~································' ,, -o\ 11 0 5 6 4 /,_ : 'A '• ··~, '• o;_· .. ~fCENS~~···~~ ..:' ' ~88io'NASg:?: ~i)W,z;L- N:Q b~r 16 ,2019 Texas Firm No. F-15209 Single Socket Size A custom·design lag boll allows you to install F lashFoot2 w ith the same 7/16" socket size u sed o n other Flu sh Mount System components. FlashFoot2 FlashFool2's seal architecture utilizes three layers ol protection . An elevated plallorm diverts water away. while a slack of rugged co mponents r aises the seal an entire inch . The seal is th en fully·encapuslaled by th e Cap. FlashFoot2 is the first solar allachment to pass the TAS·H>O Wind·Oriven Rain Test. An elevated plallorm diverts water away from the water seal. Installation Features 0 Alignment Markers Quickly align the flashing with c halk line s to find pilot hole s. @ Rounded Corners Makes it easier to handle and insert under the roo f shingles . Benefits of Concentric Loading Traditional solar attachments have a horizontal offset b etween th e ra il and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. @ Reinfo rcement Ribs Help to st iffen the fl as hin g an d prevent any bending or crinkling during installation. Vl € e;. ·c; "' a. "' u 1200 •fl,thFoot2 1000 ~ ... ' 800 600 400 .......... • FlalhFoot •L••c{Lno~ompet itor ~ a. .... Low·Colt Competitor FlashFoot2 is the only produ ct to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the sys tem. Testing & Certification Structural Certification ::> 200 0 Ra il-to-Lag Offse t (in) Designed an d Certified for Compliance with the International Bui lding Code & ASCE/SE I-7 . Water Seal Rati ngs W ater Sea ling Tested to UL 441 Section 27 "Rain Te s t" and TAS 100-95 "Wind Dr iven Ra in Test" by lntertek . Ratings applicab le for composition shi ngle roofs having slopes between 2 :12 and 12 :12. UL2703 Conforms to UL 2703 Mechanical and Bondin g Requirements . Se e Flush Mou nt In stall Manual for full ratings . f I 0 • 1 0 3 t )ESIGN & DRAFTIN G BY: DANA HAJEDEMOS 3CEP : PV-100414-010500 R OESCRIP nON DAlE REV ORIGINAL 1/15/2019 A G reen light SOLAR SYSTEMS PROJECT NAME SHEET N AM E MOUNTING DETA IL SHEET SIZE 11"x 17" SHEET NUMBER P V-3.1 ~IRONRIDGE Attn: David F. T aggart, VP Products, lronRidge Inc. Date: September 30"'. 2016 Re: Structural Certification for the lronRidge FlashFoot2 1 1495 Zephyr Avenue Hayward, CA 94!>44 1-800·227 -9523 lronRidge.com This letter addresses the structural capacity o f the l ronRidge FlashFoot2 (FF2) component for use as a roof attach ment for PV solar systems. FF2 Is composed of an aluminum Cap, a 9" x 12" aluminum flashing, and an aluminum stabilizing base. The flashing component is attached to an underlying roof rafter using a 5/16" lag bolt. The assembly details are shown in Exhibit EX-0013. The referenced uplift and lateral resistance of FF2 is based on structural tests conforming to ASTM 01761-12 "Standard Test Methods for Mechanical Fasteners i11 Wood: Testing was performed by installing a FF2 component on a sample roof deck composed of composition shingles covering Y. • OSB Board over a 2x4 Dougla s Fir rafter as shown in Figure 1. The moisture content and specific gravity of the rafter was measured and recorded per ASTM 0 2395·14 "Standard Test Methods for Density and Speci fiC Gravity (Relative Gravity} of Wood and Wood-Based Materials." The moisture content for uplift test samples was between 8% and 15% w ith an average specific gravity of 0.54. The moisture content for lateral test sam pl es was 13% with an average specific gravity of 0.54 . The critical failure mode observed for both the uplift and lateral tests was pullout of the 5/16" lag screw from the rafter. The average peak loads recorded at the critical fa ilure point for the uplift and lateral tests were 3203 lbs. and 1237 lbs., respectively. A safety factor of 3.0 was applied to certify the allowable uplift capacity to 1067 l bs. and the allowable lateral capacity to 412 lbs. for a substrate with a specific g ravity of 0 .54. For rafter wood species with specific gravity other than 0.54, the allowable uplift capacity shall be adjusted by a factor of (...E...)i per 054 AP&PA National Design Specification Eq. (12.2·1), and the allowable lateral capacities shall be adjusted per the equation I -(0.5-G) from APA Engineering Wood Construction Guide APA 2011 (G is wood specific gravity). For the common wood species, the allowable capacities are provided in Table 1. Wood Species Douglas Fir, larch Douglas Fir, South Hem. Fir Hem, Fir (North) Southern Pine Soruce, Pine, Fir ( J} The minimum siu rafter is ZX4. Table 1 . Iron Ridge FlashFoot 2 Allowable Capacit ies Ill NOS Assigned Speci fic Gravitylll 0.50 0 .46 0.43 0 .46 0.55 0.42 Allowable Uplift Capacity (lbs)U I 9S1 839 7S8 839 1097 732 (2) The listed specific gravities ore per 20JS NOS Tab le J1.3.3A. Allowable lat eral Capa cit y (lbs)lll 396 380 368 380 416 364 (3) Values ore based on securing log bolt within cen ter J/3 of rafter w idth with o minimum 2.5' end distance, and loading di rections os shown In Figure J . late ral Uphh EXHIBIT: EX-0013 ( 12.0in ) ~ -- I ---e ~4.5i n}-- 1------~ 9.0in \------"' '= = STABiliZIN G SASE FlashFool2 Cop c o n be installed in ell her orie n tation shown ITEM NO. DES CR IPT ION ASSY , FLASH ING. M IL L OR BLACK Cl 20 16 lronRidgo, Inc. 2 ASSY, CAP. MILL OR BLACK IRON RIDGE -"'""'"''''\ Flashfoot2Cerl!fiCaHon le11er·1 3 BOLTLAG5/16X4.75" ---;~OF rE \\\ ASSY . FLASHFOOT 2 ;' ~'t-. .............. ..(..t \• 4 WASHER . EPDM BACKED ,_ f? ,••' '•;'Jf$' '• -------,-----------------L~====~===========;:::=================O=W:G:·:N:O:. :::E:X·:OO:I:J====.J ·-:-.-::-·---·---·-... -.-·~,--, * : · .• , .... ~ ...................... : .... ~ f. ROGER LEWIS BLAI R 1. '-~. ................................ ~ • • tl ,,~ ... 11056 4 .:,._, ~·· ··~; t, O~··.~!CENS~~.··~~ ,.:' ~~~ ·N:Q b~r 16 ,2019 Texas Firm No. F-15209 u• IRONRIDGE 1 1495 Zephyr Avenue Hayward, CA 94544 1·800·227-9523 lronRtdge com t JESIGN & DR AFTING BY: DANA HAJEDEM OS 3CEP: PV-100414-010500 RE Vl S IONS OESCRJP noN OA 1( REV ORIGINAL 1/15/2019 A €) G reen light SOLAR SYS T EMS PRO JECT NAME SHEET NAME MO UNTING DE TAIL SHEET SIZE 11 "x17 " SHEET NUMBER PV-3.2 305 -31 5 W CLASS LEADI NG POWER OUTPU T 1 8 .9 5 % MAXI MUM EFF I CI ENCY POSITI V E POWER TOLERANCE High -Power , Ame r ica n Qua lity MiS>ion Solar Energy is headquartered in San Antonio, TX with module facilities onslte. We produce American quality product s ensuring the highest power output and reliabi lity t o our cus t o mers. Our product line is well suited l or reslden~al, commercial and utili ty applications. Every M ission Solar Energy product is certified and surpasses Indu stry stand ard regulations. proving excellent perf ormance over the long·term. www.mlsslonsolar.co m I info@mfsslonsolar.com CERTI FIED RELIAB I LITY • Tested to 3X IEC Standards • PID Resistant ADV A N CED TEC H NOLOGY • PERC and 5 busbar dri ve > 18% module efficiency • Id ea l for residential & co mm ercia l appl ications EXT REME WEATHER RESILIENCE • 5600 Pa snow load (117 psf} • 175 mph wind rating ~ BAA COMPLIANT FOR GOVERNMENT PROJECTS • Buy American Ac t • American Re covery & Re investment Act e e LINEAR WARRANTY PRODUCT WARRA NTY 5 10 15 20 YEARS CER T I FICATI ONS IEC 61215/ I EC61730/ I EC 61701 UL 1703 Iii.'\ ,§) c'-Yus Po~tGuord CEC us no · 'A5 there: kc diHCfl:'nt ccrtl flu rion rcqoitcmcnts tn diffcr~nt m.ukds. plc.nc cont.ct Y'OUf local Min ion Solar Enc~sv sales rcprcW!nt ativc for the spe<iflc ccrtlfkatcs o1pplkab&c to 1 ~ produc ts in the rcgton in whkh the produc u are to be U5<d. J!a~· ~·~ MISSI ON SDL/\R ., 1 E N ERGY • ' 25 PERC 60 ELECTRICAl SPEC IFICATIONS Elc<ttlu l Par~mettrs at St.,ndard Test Conditions {STC) Module Type M SE305SQ8K MSE310SQ8K Power Output Pmax Wp 305 310 Module Efficiency " 18 .35 18.6S Tolerance 0 '+3% 0 '+3% Short-Circuit Current l sc A Open Circuit Voltage Voc v Rated Current Imp A Rated Voltage Vm p v Fuse Ra~ng TEMPERATURE COEFFICIENTS Normal Operating Cell Temperat ure {NOCT) Temperature Coefficient of Pmax Temperature Coefficient of Voc Temper ature Coefficient of lsc OPERATING CONDITIONS 1,000VDC 9 .723 39.96 9 .238 33.02 20 44•c (t2•c) -0.427%/"C ·0.318%/"C 0 .042'lWC 9.819 40.09 9.362 33.11 20 Maximum System Voltage Operating Temperature Range Maximum Series Fuse Rati ng Fi re Safety Classification -40'C (·40°F) to +9o•c (194°F) 20A Front & Back Load (U L standard) Hall Safety Impact Velocity Type 1. Class C 5600 Pa {117 psi) 25mm at 23 m /s MECHANICAL DATA Solar Cells Ce ll orientation P-lype M ono-crystalline Silicon {156 .75m m) 60 cell s {6x 10), 5 busbar 1664mm x 999mm x 40mm l65.51in. x 39.33 in. x 1.57 in.) Module dimension Weight Front Glass Frame Encapsu lant J·Box Cables Connector 18.2 kg (40.11b) 3.2mm (0.126 ln.) t empered, Low-iron, Anti -renective coating Anodi zed aluminum alloy Ethylene v inyl ace tate {EVA) Protection class IP67 w ith 3 bypass-diodes PVwlre, 1m (39.37 in.). 4mm' I 12 AWG MC4 or compatible SHIPPING INFORMATION Contai ner FT Pallets Panels 305W 53' Double stack 36 936 285.48 kW 40' Double st ack 28 728 222 .04 kW Panels Weight He ight Widt h Pallet 26 1.1601bs 45.15' 45.00' Length 66.00 CLASS LEADING 305-31SW CERTIFICATIONS & TESTS MSE31SSQ8K IEC 3 1 5 18.95 0'+3% 9.917 40.13 9.465 33.2 8 20 " 61215 /61730 /61701. Salt mist UL UL 170 31istcd ( ~) w e@ us J, 'owetGuCHd CEC usno MSE315SQ8K: 315WP, 60CELL SOLAR MODULE CURRENT ·VOLTAGE CURVE Incident lrrd.al ,OOO W/m 10 -----------'---........ Inciden t hr d.a8()() 5: lncldC!nt hrd,s600 Inciden t 1H d .:400 ~ . ---------------~ lnddenl lud.:200 ~ " IJJ ., VolugeiVJ Currc nt•voltage characteris tics with dependence on lrradiancc and module temperatu re BASI C DESIGN (UN ITS: mm) .. Fron t Vi ew ,. '• "'"" -r;;51 r I ~-- I-• Grounding - /. ..... Back View . ·--: . .~ ~\· MISSION SOL/\; ., ENER GY .• ' Mission Sol•t [netcv 1 8~03 S New Braunfels A11C! , S~n Anlonlo, T~~~~ 78235 lnfo$tni ~~ionsol.u com I www miulonsolo~r com DESIGN & DRAFTI NG BY: DANA HAJEDE MOS NABCEP : PV-100414-010500 ORIGIN ... L 1/15/2019 A 8 G ree nlight S OLA R SY S TEMS PROJECT NAME SHEET NAME EQU IPM EN T SPEC IFI CAT I ON SHEETS SHEET SIZE 11 "x17 " SHEET NUMBER P V -4 r 111 1 Enphase Microi nve rt ers Prq.~'" AMI PICAS En phase IQ 7 and IQ 7+ Microinverters To l earn more abou t En phase offering s. vis it enphase.com Th e hig h-powered sma rt grid-ready Enphase IQ 7 M i cro '" and Enphase IQ 7+ Micro·· dram atica lly simpl ify th e ins tallati on process wh ile achiev in g the highes t system eff1ciency. Part of the Enp hase 10 Syst em. t he 10 7 an d 10 7+ Microinvert ers integ rate w ith the Enphase 10 Envo yN, Enph ase 10 Battery'". and th e Enp hase Enligh ten'" moni tori ng and analysis software . 10 Seri es Microinver ters ex tend t he rel iability standards set for th by prev io us g enera tions and unde rgo over a mi ll ion hours o f power-on testi ng, enab lin g Enpha se to prov ide an ind ust ry-lead ing warranty o f up to 25 yea rs. Easy to Install Ligh t weigh t and si mple Fas ter i n st alla t ion w ith improved, l ight er t wo -w ire cabling Built-in rapid s hutdow n c omplian t (NEC 2014 & 2017) Prod ucti ve and Reliable • Opti mize d for h igh p ow e1ed 60·cell and 72-cell' modu les M01e than a million h ou rs of t est in g Class II d o u b le-insu lated enclosure UL li sted Smart Grid Ready Complies with advan ced grid s u ppor t. voltage and fr e que ncy rid e·l hrough requi re m ents Rem o tely updat es t o resp ond to c h angi ng g rid requirement s Conf1gu rable for varyi ng gnd profiles Meets CA Ru le 21 (U L 1741·SA) ·The IQ 7 • ~hero 1s requtred 10 suppon12-cell modules 9 ENPHAS E Enphase IQ 7 and IQ 7+ Microinverters I NPUT DATA (DC) 10 7·60 ·2-US /107·60·0 -US 107PL US·72·2·US /IQ7PLUS ·72·B ·US 'COmmonly used modu le pairings' M odul e com patibihty ~-350W+ --2-35 w. 440 w + M aximum inp ut DC voltage Pe ak power t racking vo l tage Operating range Mi n/Max st art voltage Max DC sho rt c irc uit c urrent (module lsc) Over voltage class DC port DC p or t back feed current PV array confi guration OUTPUT DATA (AC) Peak o ut put power M axim um c ontin uous o utput power Nominal (L·L) voltage/range' Maximum co ntinuou s o utput c urrent Nominal frequency Ex tended freque nc y r ange AC s hort circuit fault current ove r 3 cycl es Maximum un its p er 20 A (L·l ) branch c i rcUJI' Overvoltage class AC p or t AC p ort back feed current Power f ac tor se lling Power f ac tor (adjustable) EFFI CI ENCY Pea k eff1ciency CEC weigh ted efficien c y MECHANICAL DATA Ambient t emperat ure r a n ge Rel at ive humidi ty range Conn ector type (107·60·2-US & IQ7PLU S·72·2·US) Connec tor type (IQ7·60·B·US & 107PLUS·72·B·US) Di m ensions (Wx HxD) Wei ght Cooling App roved for w et locat ion s Pollu t ion d egree Enclosure Environmen tal category 1 UV exposure rat ing FEATUR ES Com municati on Monitorin g Di sconnectin g means Comp lian ce 6 0·cell PV modules onl y 4 8V 27 V · 37V 16V·4 8V 22 v /48 v 15A II O A 60·cell and 72·cell PV modules 60 v 27V·4 5V 16 V ·60V 22 v /60 v 15A II OA 1 x 1 ungrounded array; No addit ional DC side prot ection required; AC side prot ection reqUJres max 20A per branch c11cu it IQ 7 M lcroi nvert er IQ 7+ Mlcrolnverler 2 50VA 295VA 2 40VA 290VA 24 0 V I 208V I 240V I 208V I 211 ·264 v 183·229 V 21 1·264 v 183·229 V 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) 60Hz 60 Hz 4 7 ·68Hz 47-68Hz 5.8 Arms 5.8Arms 16 (240VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Ill Ill O A OA 1.0 1.0 0.85 leading ... 0.85 laggin g 0.85 leading ... 0 .85 lag ging @2 4 0 v @208 v @240 v @208 v 97.6% 97.6% ~ 97.3% ___ 97.0 % 97.0% 97.0 % 97.0 % -4o•c to +65°C 4% to 100% (condensing) MC4 (or Amphenol H4 UT X wit h additional O·DCC-5 adapter) Friends PV2 (M C4 intermateable). Adaptors for modules with MC4 or UTX connectors. • P V2 to M C4: order ECA·S20·S22 · P V2 to UTX: order ECA·S20·S25 212 mm x 175 mm x 30.2 mm (wit hou t bracket ) 1.08 kg (2.381bs) Natural convec tion· No fans Yes PD3 Class II double-insulated, corrosion resistant polyme11c encl osure NEMA Type 6 / outdoor PowerUne Communication (PLC) Enhghten Manager and MyEn li ghten momtormg options. Both options require Installation of an Enphase IQ Envoy. The AC and DC connect ors have been eval uated and app1oved by UL for use as the load-break disconnect required by NEC 690. CA Ru le 21 (UL 1741-SA) UL 621 09·1, Ul1741/IEEE1547, FCC Part 15 Class B. ICES-0 003 Class B. CAN /CSA·C22 2 NO 107.1-01 This product is UL listed as PV Rapid Shut Down EqUipment and conforms vmh NEC-2014 and NEC -20 17 sec11on 690.12 and C22.1·2015 Rule 64·218 Rapid Shutdown of PV Systems. for AC and DC conductors, when 1nstalled accord1ng manufac t urer's mstrucllons 1 No enforced OC/AC ra110. See the compattb•hty calculato1 at hli~.JlJ:.[Ulbose.c.o.r:nltn.:u..$/llP.PW..llmwluli:.:t.CUDDAltiUltW 2 . Nom mal vo ltage range can b e extended beyond nominal •f rcqutrcd by !he ut•l•ty 3 Llm•ls may vary. Refer to local rcqUircmcnls to dcf me the number of nHcrotnvcners per br anch m your arc3 To lea rn mor e abou t Enphase offerings, vi sit enp hase.com 2018 Er pl·a :~~ (ntrg,-.'\' t:r;t·t ,. '( .t t •.:·l AIIUat't.m..t•!.:s vr l:r ,,n,•· o d ... , •h~;~ 11' l·•tv vf fn~11dSe fn.:rgy tn( 20t8 ttlg 9 ENPH ASE DESI GN & DRAFTING BY: DAN A HAJEDE MOS NABCEP : PV-1004 14-D10500 R DESCRIPn ON RE V ORIGINAL 1/15/201 9 A CD G reen light SOLAR SYSTEMS PROJEC T N AM E SHEET NAME EQU IPMENT SPE CIFICA TION SHEETS SHEET SIZE 1 1"x 1 7 " SHEET NUMBER PV-5 Di.lta Sheet Enphase Networking En phase IQ Combiner (X-IQ-AM1 -240-B) ® LISTED To l earn more about En phase off er ings, vi si t enphase.co m The Enp hase IQ Combi ner '" wit h Enphase IQ Envoy '" consolidates int erconnec tion equipment into a single enclosure and strea m li nes PV installa tions by prov iding a consis ten t. pre -wired so lu tion for resident ial applications. Smart Includes IQ Envoy for communication and con t rol Fl exi b le n etworking suppor t s Wi·Fi, Ethernet , or cell ular Si mple • Three pre-installed 20 A I 2 40 VAC ci r c uit breaker s Provides production m e te ri ng and optional consumpt ion monitoring. Reliab le Durable NRTL·certif1ed NEM A type 3 R enclosure Five-year warranty 9 ENPHASE Enphase IQ Combiner MOD EL NUMBER IQ Comb ine r X·IQ·AM 1·240·B ACCESSORIES (order separately) Enphase M obile Connect ~ CELLMODEM ·03 (4G /12·year data pl;m) CELLMODEM ·01 (3G I 5-year data plan) Consumpt ion Mo ni toring CT CT·2 00·SPUT EL ECTR IC AL S P ECI FICATION S Rating Solar branch circ uit br eakers Maximum sy stem voltage Rated output cu rrent Rated Input current, eac h input Maximum fuse/circuit breaker rating (ou tput) Production Metering CT MECHANICAL DATA Dimensions (WxHxD) We ig ht Ambient t emperature range Cooling Enclosure envi ronmental rating Wire size Altitude INTERNET CO NNECTION OPTIONS Integrated Wi·Fi Ethernet Cellular COMPLIANCE Compliance, Combi ne r Compliance. IQ Envoy IQ Combiner with En ph as e IQ Env o y·· for in tegr ated revenue grade PV production me tering (A NS I C 12.20 +/· 0.5%) and optional consumption monitoring(+/· 2.5%). Plug and play industrial grade cellular modem wi th data plan for systems up to 60 microlnver ters . (Ava i lable in the US, Canada. M exico, Puer to Rico. and the US Vi rgin Islands. where there Is adequate cellu lar service In the Installation area.) Sp lit core current transformers enable whole home consu mption metering(+/· 2.5 %). Continuous duty Three 2-pole 20 A/240 VAC DIN rail-mounted breake rs 240 VAC 4 8A 16A 60A 200 A solid core pre· installed and w ired to IQ Envoy 38.0 X 38.7 X 20.3 em (15.0" X 15.3" X 8.0 ") 5.1 kg (1 1.2 1bs) ·40° C to +46° C (·40° to 115° F) Ven ted, natur al convection, plus hea t shield Outdoor, NRTL·certif1ed, NEMA type 3R, polycarbonate construction 14 to 6 AWG copper con ductors for branch in puts. 14 to 4 AWG copper con ductors for combined output. Follow local code requirements for conductor si zing. To 2000 me ters (6 ,560 fee l ) --------------- 802.11b/g/n 802.3, Cat5E (or Cat 6) UTP Ethernet cable· not in cl ud ed Optional, CELLMODEM ·Ol (3G) or CELLMODEM·03 (4G) ·not Incl uded UL 174 1 UL 916 CA N/CSA C22.2 No. 61010·1 47 CFR. Pa r t 15. Cl ass B. ICES 003 IEC /EN 61010·1:2010, EN50065·1 . EN61000·4·5, EN61000·6·1. EN6100 0·6·2 Meteri ng : ANS I C12 .20 ac c ura cy class 0.5 To lear n more about Enphase offerings, v isit enp hase.com 2017 l nphase lnergy AI ughts rctC'rved All lladernarks or b1ar,tl:i tn t h1~ docUinC'nt d ll· u .. •g 1~h;rt:d Ut the.r respect1v~ O\\ner 20 17·08 17 9 ENPHASE. DAN A HAJEDEMOS llCEP: PV-1004 t 4 -010500 t lESIGN & DRAFTING BY: DESCRIPTI ON ORIGINA L t /t 5/2019 A 8 G reen light SOL /\R SYSTEMS PROJECT NAME SHEE T NAME EQUIPME NT SPEC IFICATION SHE ETS SHEET SIZE 11"x 1 7 " SHEET NUMBER P V-6 PHOTOVOLTAIC ELECTRICA L DIAGRAM CABLE SCHEDULE AND CALC5 CIRCUIT CONDUCTOR CONDUCTOR CONDUCTOR LONGEST CONDUCTOR GROUND GII-OUND GROUND CONDUIT CONDUIT FILL SERVICE QTY INSULATION I.D. # SIZE AMPACITY MATERI AL LENGTH(FT) (90'CJ SIZE QUANTITY INSULATION TYFE DE RATE I AC 3 AWG #1 2 30 cu 70 0-CABLE AWG #8 I BARE FREE AIR I OREMT 2 AC 4; 2 AWG #10 40 cu 40 THWN -2 AWG #8 I THWN-2 EMT 0 .8 3 AC 3 AWG #G 75 cu 10 THWN-2 AWG #8 I TH WN-2 EMT I GENERAL NOTES : 1. INSTALLATION SHALL BE AC CORDING TO THE NATIONAL ELECTRIC CODE 2017 AND ALL STATE AND LOCAL STANDARDS AND CODES . 2. INSTALL LABELS ON ALL ENCLOSURES, INVERTERS, SWITCHES , LOAD CENTERS AS PER NEC . 3 . AC DI SC ONNECT SHALL BE EXTERNALLY OPERATED KNIFE BLADE TYPE AND LO CKABLE IN BOTH ON AND OFF POSITIONS, AND DIRECTLY ACCESSIBLE TO UTILI TY. 4 . ALL ELECTRICAL WORK WIL L COMPLY AND BE INSPECTED BY A LICENSED MASTER ELECTRICIAN AND ALL LOCAL CODE AUTHORITIES . 5 . CONTRACTOR IS RE SPON SIBLE FOR ENSURING INSTALLATION IS PER NEC & MANUFACTURER'S DESI GN SPE C. 6 . ALL CONDUCTORS SHALL BE COPPER , RATED FOR 600V AND 90'C, AND RUN IN CONDUI T. 7 . CONTINUOUS GROUND IS REQUIRED. IRREVER SIBLE COMPRESSION CLAMP S REQUIRED FOR ALL GROUND SPLICES. 8 . MICROINVERTERS COMPLY WITH RAPID SHUTDOWN PER 2017 NEC . RAPID SHUTDOWN SIGNAGE SHALL BE INSTALLED PER NEC 2017 , SEE SHEET E-2 . TRAN SITION BOX -ROOF 1 AGGR EGATE PANEL 125A ~AIN LUC ONLY NEMA JR, UL USTED (2) 20 A 2-POLE BREAK ER S AC DISCONNECt 240 VAC, 60 A NEMA JR. UL LISTED (2) 60 A FUSES IIISIBL£. LOCK ABLE , LABELED. \\!tHIN 10' Or METER CONDUIT TEM P SIZE DERATE N/A 0.7 1 3/4" 0.71 3/4 ' 0.9 1 TO UTILI TY GRI D DERATED AM PACITY 28.4A 22.72A G8.25A BI-DIRECTIONAL UTI LIT Y ME TER 1-PH ASE, 240 V MAX CIRCUIT CURRENT IGA I GA 4 5A MAIN SERVICE PANE L CE LOAD CENTER I-PH. 3-W 240 VAC 200A BUS, 200A MAIN BREAKER SU PPLY SIDE INTERCONNECTION G -~ '---'l I .A ........ Bronch Circuit 2 : .------, Roof 1 (7) & Roof 2 .-----~ ~----, .------, (16) 310W MODULES (16 ) ENPHASE 107 ........... ===@--l I I I I Bronch Circuit 3: Roor 3 (13) 31 0W MODULES (13) ENPHASE 107 20 A I L...::=j~~~ l I I I EXISnNG GROUNDI NG L - ---_j I ELEC TRODE SYS TE M _j__ t >ESIGN & DRAFnNG BY: DANA HAJEO EMOS lCEP: PV-100414 -010500 OESCRIPnON ORI GINAL 1/15/2019 A @} G reen light SOLAR SYSTEM S PR OJECT NAME SHEET NAME ELECTRICAL DI AGRAM SHEET SI ZE 11"x 17" SHEET NUMBER E -1 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: 45 A NOMINAL OPERATING AC VOLTAGE : 240 V ~R~E~Q...!:'D:.....B~Y!.'-.: ....:N~E~C....:6"-"9~0'-"'.5-'-4 ---~ APPLY TO: PV AC DI SCONNEC T THIS PREMISE IS SUPPLIED BY MORE THAN ONE SOURCE OF ELECTRIC POWER (UTILITY, SOLAR PV) REQ 'D BY: NE C 705.10 f"2l MAIN SERVICE PANEL ~ WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE . ~RE~O<!....!'DLJ2B:..!.;Y:'--...!.::!.NE~C-!........!..:.70~5~.1~2_](~BA)(..=.2 )LI..( 3:,!.J.)~(bu..) -~[2] INTE RCONNE CTION BREAKER INVERTER OUTPUT CIRCUIT CON NECTION S IN AG G PAN EL WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE , SHALL NOT EXCEED AMPACITY OF BUSBAR ~Rf.!EO-:L.'D!LEB~Y~: .!::!N.s.!EC~7:::!:05-!.:....1~2,....:(1..EB~)(..=.21..l.)(~3 )u..:( c-:..1.) __ 0 P OI NT OF INTER CO NNECTION (MAIN SER VICE PANEL) WARNING-ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT REQ ' BY : 690.13(B) AND 690.15 APPLY TO: DIS CO NN ECTS WARNING THIS DISCONNECTION OF THE GROUNDED CONDUCTORS MAY RESULT IN OVERVOL TAGE ON THE EQUIPMENT RE Q'D BY: NE C 690 3 1(1) APPL Y TO: N/A BIPOL AR PV SYSTEM PV SYSTEM DC DISCONNECT MAXIMUM VOLTAGE : NA V DC MAXIMUM CIRCUIT CURRENT: NA ADC MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC TO DC CONVERTER: NA A ~R~E~o·~o....:B~Y~:~N~E~C ~6~9~0.~53~--GJ APPLY TO: INVERTER IN TEGRATED DC DISCONNECT WARNING-ELECTRIC SHOCK-HAZARD ( TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSiriON ...!R~E~Q_' !:!..BY.!..:.:-.:6~9~0.:..!..1!!..3 ----~ APPLY TO: AC DISCONNEC T RAPID SHUTDOWN PV ARRAY ~R~E~O_'~BY~:~6~9~0.~1,2~(~B)~(2~)----~ APPLY TO: SOLAR CONDU IT IN SIDE ARRAY BOUNDAR Y I WARNING-PHOTOVOL TAlC POWER SOURCE I REO' BY: 690.3 1 (G)(3) G APPLY TO: SOLAR CONDU IT I WARNING-DO NOT DISCONNECT UNDER LOAD I REO ' BY: 690.15(C) G APPLY TO: REVENUE METER RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM REO' B Y: NE C 690.56(C)(3) ~ APPLY TO : P V AC DISCONNECT . ~~-------------------------------. ! PHOTOVOL TAlC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TU RN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY ...!Rl.!:E~O_' ~BY.!..:.:....:N~E~C....:6~9~0:..:=. 5~6(~C:.Lll(..:...1 )""( o"-'2--GJ BL ACK ON YELLOW BACKGROU ND AP PLY TO: PV AC DISCONNECT ~;NAGE REOUIREMEN TS > RED BACKGROUND > WHITE LETTERING > MIN . 3/8" LETT ER HEI GHT > ALL CAP IT AL LETTER S > ARIAL OR SI MILAR FONT > REFLE CTIVE, WEATHER RES ISTA NT MATE RIAL, UL 969 - DAN A HAJEDEM OS BCEP: PV-100414-010500 t )E SIGN & DRAF TI NG BY: 11E_VI S!ONS DESCRIPnON DATE REV ORIGINAL 1/15/2019 A 'tD G reen light SOLAR SYS TEM S PROJECT NAME W N w >m ucr::o zo<D w I"- oo --ox (f) O f-w 0:: 3: - (f)W o._C)::::S::: 2Z<( <(::::.::::_] u ~ w~:::::> o~o ~(f) J SHEE T NAME SYSTEM LABE LI N G DETA IL SHEET SIZ E 11"x 1 7" SHEET NUMBER E-2