Loading...
Item 6A PlansSouthlake meadows Simpson 8 sonsTradln❑ r ir..-7 i a W G ik W I nd.=3i `'-'-r PV System Solar PV System Location :on Wireless Q North Park Flag Football Southlake DPS North, Liberty Park A Training Center i Sheltonwoos North Park (� E Dove Rd Daa a Rd Winfield Est ,u Carlllort Southlake Q 9 Silverado Greg Lonnle Wllllarns Q ru­mnyrcu w eir= aar� at Southlake b ,y, r Welding Sbrvlces .5 s Allegiance Title p� '�j. �+y, Southlake Western Union q n Company Southlake lI '�� M Animal Hospital G The Manogt Mlnt P f y e T N 160A Devon Court s 3 � e 1Nka® Lo - s N4agv"'�uO rH � �dwet Highland Landscapmg Q .luti�bVv"� ?+� F'llnw0ip Church-- V kellur/SoviNake Campus r�as,r �4r+oi 3 wind+�catk G m Q s N � x,vsu GIa�Alllin'r�+ fir¢ Countryside. Bible Church Falcon Holdings LLC �} [;race Community�y Church AY✓f Mike's Garden Center f New Day Church Gy Ei, y a,us at Southlake Y E .. L >iry E - Carroll Nigh School p a. S Cc r Owner: C.D. Peebles 1604 Devon Court Southlake, TX 76092 Axium Solar: 1005 Placid Ave. STE 100 Plano, TX 75074 O: 972-633-8680 Andrew Whitehead Business Development Manager and rewwhitehead@axiumsolar.com Charles Wright, BSEE Project Engineer charleswright@axiumsolar.com Project Description Installation of a rooftop solar array on the West and South facing rooftops. SolarEdge inverter mounted on interior garage wall of house, SE optimizers mounted under each module to comply with rapid shutdown requirements and utility disconnect mounted on the South exterior wall of house, near meter. Applicable Building Code Compliance 2017 National Electric Code (including 690.12, rapid shutdown) 2018 IRC / IBC 2018 IFC (1204) Drawing Index PV 100 Cover Page PV 101 Site Layout PV 102 One Line Electrical PV 103 Attachment Detail PV 104 Labels 0% AXIOM SOLAR 1005 PLACID AVE. (855) 633-8680 SUITE 100 (972) 633-8680 PLANO, TX 75074 WWW.AXIUMSOLAR.COM �oo�,c�opp�4 OF .TFCC v � .•° 9s��Co BENNETT A. FORD D �...........................c 13 109875 S N PLAINVIEW ENGINEERING LLC TX FIRM# 20680 11-11-2019; ELECTRICAL ONLY PROJECT: C.D. PEEBLES SOLAR PV SYSTEM ADDRESS: 1604 DEVON COURT SOUTHLAKE, TX 76092 REVISIONS TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 30OW MODULES (1) SOLAREDGE 7.6KW INVERTER(S) SNAPNRACK SERIES 100 RACKING 40o & ----0 TILT(S) 275o & 185o ORIENTATION(S) Utilitv Meter. ESI ID# ? DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE CONSTRUCTION COVER PAGE PV 100 Coventry Lane Property Line - �81 o� N U E O w c E � I 1 1 1 1 1 / No. shown in module indicates string# ' 2 ` 1 2 1 Single module width is 39 1/8" 2 2 1 1 � PV Inverter - m/n SE760OH-US 2 - � PV AC Disconnect 0 Main Electrical Panel 65 E0 Utility Meter 1so.s~ 196" Garage 1.5" Notes: 1) No equipment will extend beyond the limits of existing building footprint. No property setbacks will be encroached upon. 2) Solar modules to be mounted to existing roof structure. 3) Exact layout to be adjusted as required to avoid roof and plumbing vents. 4) Locate solar AC disconnect within 10 feet of utility meter. 5) Installation to comply with the requirements of Section 1204 of IFC 2018. 6) Coordinate with homeowner for all equipment and conduit placements. Visible, Lockable Labeled, AC Disconnect (Located Min 10' of meter) Neighboring Property SITE PLAN N Solar Modules (M/N: TSM-300DD05A.05) i I Driveway EA, 40* AXIUM SOLAR 1005 PLACID AVE. (855) 633:8680 SUITE 100 (972) 6338680 PLANO, TX 75074 WWW.AXIUMSOLAR.COM ���cOF c�opGG ....... BENNETT A. FORD C �........................... 109875 PLAINVIEW ENGINEERING LLC TX FIRM# 20680 11-11-2019; ELECTRICAL ONLY PROJECT: C.D. PEEBLES SOLAR PV SYSTEM ADDRESS: 1604 DEVON COURT SOUTHLAKE, TX 76092 REVISIONS TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 30OW MODULES (1) SOLAREDGE 7.6KW INVERTER(5) SNAPNRACK SERIES 100 RACKING 40° & ----0 TILT(S) 275° & 185° ORIENTATION(S) Utility Meter. ESI ID# ? DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE 1/16" = V-0" CONSTRUCTION SITE LAYOUT PV 101 Peebles Residence - PV Wire Calculations ASH RAE Temperatures Totals Characteristics Qty. Nominal Short -Circuit Temperature Coefficients (%/°C) Coldest DaY Voc Warmest Day Vmp 2%High (°C) Extreme Min(°C) 2%High (°F) Extreme Min STC Watts / System Size (STC pTC Watts / System Size (PTC (,Fl Modules Module kSi Module kW) Inverter Efficiency System Size (CEC AC ize Modules Vmp Imp Voc Isc Voc Isc Pmax Site 37 -7 98.6 19.4 29 1300 8.70 270.60 7.85 96.2 % 7.55 Single Trina Allmax Plus 30OW (TSM-DD05A.05(11)) 1 32.60 9.19 39.80 9.77 .0,29 0.050 -0.39 43.49 27.26 Optimizers Volts Note: Values below r--------alYNirtBf02 Mt 'wtotalnum6erafN "' nduttprs run'n home mn cpndurcminverter. (EGCI' Tempera!u Adder bCu Approx. One -Way gmbien(Temperature ying Amps Maw mpSm Con[mps y OCPD size (Amps) Distance lft.) ('FI (°n Temperature Factor onductorz onduit Flll Factor tied Amps COD Corrected Mlnimum Wlre Calculated%Vtlrop at selectetl Wire Calculated%Vdrop at Amps Selected Selected EGC 512 Mc..%m m10 EG solarEdgeywo string pl is 400 1 M t5 18.8 n 0 0.91 4 0.8 18.8 2s.8 10 0.35% to SolarEdge 7600 string b2 la 400 30.z0 tS 18.8 0 0.91 4 0.8 18.8 29.8 12 0.z2% 10 0.33% 10 to 50-dge 7600 stung b3 0.00 11 18.8 100 0 0.91 4 0.8 18.a 12 0.00% 10 0.00% 10 10 Max Output "' y - Volt ps (Phases) 12z%of Maw Amps OCPD size (Amps) Approx. One -Way Distance (k.l Ambient Temperature ("FI emperature Adder ('F) emperature Factor n[Carrying ontlucrors ontlui[Fill Factor cted Amps C.- Corrcred Amps Mlnimum Wlre 5i8e z Calculatetl%Vdrop at nimu M3.80%m selected Wire 58e iz Calculated%Vdropac Selected 0 mum EG Selected EGC Inverter to Panel 240 32 32 40.0 40 100 100 0 0.91 3 3 40.0 440 180% 10 10 Note: Calculations shown are based on installation of SWC conductors. Some equipment lugs are rated at 75'C and conductors verified to remain within limits. Some conductors may have been upsized for voltage drop. Copper conductors unless otherwise noted on drawings. Note: COU (Conditions of Use) Corrected Amps refers to conductor derating. NEC Table 310.15(B)(2)(A), 75°C column used for temperature derating. NEC Table 310.15(B)(3)(a) used as conduit fill derating. NEC Table 310.15(B)(16) used for conductor ampacity. Note: Ambient Temperature sourced from ASHRAE 2%high values and appropriate temperature adder from NEC table 310,15(B)(3)(C) applied. Amperage escalated to select appropriate conductor. Calculations above based on: ffaipipli7&e) Operating Current=(#strings)"(Imp) Operating Voltage=(#modules in series)"(Vmp) Short Circuit Current=(#strings)"1.25 per NEC 690.8(A)(1) Max System Voltage=(#modules in series)'((((-.#N%V/°C".01)"(lowest temp C-25))"Voc))+Voc)I SHEET NOTES: 1. THE INSTALLATION OF THIS SOLAR PV SYSTEM SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE (NEC). 2. DERATE CONDUCTORS FOR ACTUAL INSTALLATION CONDITIONS. 3. ALL DISTANCES SHOWN ARE ESTIMATES ONLY. ACTUAL DISTANCES WILL VARY AND SHALL BE VERIFIED ON SITE. 4. CONDUIT, WHERE INSTALLED, SHALL BE AS FOLLOWS: 4.1. ABOVEGROUND - EMT W/ ALL -STEEL COMPRESSION TYPE FITTINGS. 4.2. UNDERGROUND - SCH40 PVC 4.3. SUPPLY-SIDE / SERVICE ENTRANCE / WHERE SUBJECT TO DAMAGE - GALV. RIGID STEEL 5. EGC REFERS TO EQUIPMENT GROUNDING CONDUCTOR; GEC REFERS TO GROUNDING ELECTRODE CONDUCTOR. 6. ALL CONDUCTORS SHALL BE COPPER. 7. ELECTRICAL EQUIPMENT AND MATERIALS APPROVED, LISTED, LABELED, IDENTIFIED AND INSTALLED PER A NATIONALLY RECOGNIZED ELECTRICAL TESTING LABORATORY. 8. SERVICE EQUIPMENT LABELED PER NEC FOR DUAL SOURCES. PV EQUIPMENT/SYSTEM LABELING PER NEC 690. Router, connection to I Sense Circuit Breaker Provided by Customer ternet Sense Antenna must be 2 pole (no tandum breakers) DC Conductors 2#10 PVWire per string of optimizers to Inverter 1#10G EGC THWN-2, 1" Raceway Solar Modules Junction Box (AR) DC Optimizer Sense String of 15 Optimizers (15 modules) Unit Un t2��A/2 0 0 3#8 THWN -2 SE Zigbee Comms = �_ J -_ 1#10G THWN-2 M Min. 3/4" Conduit 200A t° Typical Main `v L 0 Z J_ F Built-in DC Optimizer whips (#10 PVWire). Sense CTs �i Field -installed #10 PVWire jumpers installed 1 set on incoming service as necessary. (TYPICAL) lines, 1 set on PV input Equipment Grounding Conductors (TYPICAL) #6 Bare within array, #10G THWN-2 in conduit - - - - - - - - - - - - - 4 0 A _ String of 14 Optimizers (14 modules) AC Grounding J Electrode System AC SPDVisible, 7-j-i-L Lockable, LL Labeled Solar PV AC Disconnect (Located w/in 10' of utility meter) EQUIPMENT UTILITY METER MAIN ELECTRICAL PANEL SOLAR PV AC DISCONNECT SOLAR INVERTER SOLAR MODULES LOCATION SERVICE ENTRANCE SOUTH INTERIOR GARAGE WALL EAST EXTERIOR WALL TBD SOUTH & WEST -FACING ROOFTOPS [Existing] [Existing] [New / By Axium Solar] [New / By Axium Solar] [New / By Axium Solar] 200 A 200 A MCB, 200 A Bus Trina Allmax 30OW Modules (M/N: TSM-30ODD05A.05) 240/120 VAC 240/120, 10, 3W Fused Disconnect SolarEdge Inverter SolarEdge, P400 Optimizers w/ 2 - 40A Fuses (1) SE760OH-US MC4 connectors, PVWire module and optimizer leads. Modules Utility Meter Breakers are GE Q-Line type 2P, 60A, 240VAC are compatible with ungrounded / transformer -less inverter ESI ID# ? NEMA 3R Enclosure 240V, NEMA 3R topology. NOTES For solar interconnection, perform line -side tap of incoming 32A Maximum Output Amps supply feeders of main electrical panel. Each module is attached to an optimizer. Optimizers are wired Install 240V AC surge Integral Arc Fault protection in series. Modules are UL 1703 listed. Optimizers are listed, Install Sense energy monitor with added 20A/2P breaker in protection Integral DC Disconnect UL1741, UL-94. Clips attached to module frames and wire tray main panel. Shown installed inside panel board, but may Integral Rapid Shutdown Capable on racking system support conductors. Modules bonded to work better to install externally using the supplied bracket. racking system via UL listed module clamps. Optimizers bonded Inverter is listed, UL 1741 via #6 bare, solid EGC. Install ground lug on each independent array assembly. Monitoring means: SE Zigbee Wireless DC+ conductor jacket is red and DC- is black. 0% AXIUM SOLAR 1005 PLACID AVE. 1855)633-8680 SUITE 100 (972) 633-8680 PLANO, TX 75074 W W W.AXIUMSOLAR.COM BENNETi A. FORD 109875 ��•4Q, PLAINVIEW ENGINEERING LLC TX FIRM# 20680 11-11-2019; ELECTRICAL ONLY PROJECT: C.D. PEEBLES SOLAR PV SYSTEM ADDRESS: 1604 DEVON COURT SOUTHLAKE, TX 76092 REVISIONS TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 30OW MODULES (1) SOLAREDGE 7.6KW INVERTER SNAPNRACK SERIES 100 RACKING 400 TILT 2750 and 1850 ORIENTATIONS Utility Meter, ESI ID# ? DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE CONSTRUCTION ONE LINE ELECTRICAL PV 102 SNAPNRACK SERIES 1DD RACKING SYSTEM TYPICAL ROOF LAYOUT NOTES: - STANDARD LAG BOLT SPEC ASSUMES W 16" LAG BOLTS WITH 2.5" EMBEDMENT IN ROOF STRUCTURAL. MEMBERS/RAFTERS - TORQUE ALL A" HARDWARE TO THE FOLLOWING: -SILVER S-S. 10.16 FT -LIPS - BLACK S.S- 7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF POST (UPSLOPE vs- DOWNSLOPE) -FOR UNEVEN ROOF SURFACES, USE UP TO TWO LEVELING SPACERS PER L FOOT OR STANDOFF. SEE DRAWING P "STANDARD RAIL LEVELING' FOR DETAILS AND LIMITATIONS .- STANDOFFS ARE BOLTED INTO ROOF RAFTERS OR STRUCTURAL MEMBER Z '" "RAIL SPAN" DISTANCE BETWEEN ROOF ATTACHMENTS 4-6 Feet Preferred 2 UL4U n A f� =F2iT!!T ENERO�C(M DESIGNER. G At>PUHNxe IIID,'JVI IIrAT�I171�41'LJITuQ➢� •.. .....e.....�-.._. DRAFTER. U( PV -___= APPRGVEDBY: SNAPNRACK SERIES 100 RACKING SYSTEM SHOWN MOUNTED ON STANDOFFS J' X 2.75' (TYP.) S.S. BOLT WITH SPLIT LOCK WASHER SNAPNRACK MID CLAMP SNAPNRACK CHANNEL NUT SNAPNRACK UNIVERSAL m END CLAMP ASSEMBLY SnapNrack Bonding Lug Assembly C 5NAPNRA.a( STANDARD PAIL .rT _1M JR�OSUQIEL -'-BONDING SJS6.1H%1[N— � f STAINLESS BOLT 1 IJ 5116 IN STAINLESS J+PPER WIRE, TYP. SPLIT LOCK WASHER SNAPNPAEK GROUHIID J' LUG, 6-17AN5 ROOF RAFTERS OR STRUCTURAL MEMBERS SNAPNRACK MODULE MID CLAMPS MODULE OVERHANG (NOT TO EXCEED 30% OR MANUFACTURERS RECOMMENDATIONS) Trina AIIMax Modules to be ' between 0" and 16" (0" and 9"in Landscape) MODULE OVERHANG ._ a. Center to Center -- rail spacing: 34" min, 63.5" max "RAIL END OVERHANG' (NOT TO EXCEED 34 % OF ACCEPTABLE RAIL SPAN) LR SCALE: DNS PARTNUMBER. DESCRIFTIDN: O"TE. SI00 D05 SERIES IGO TYPICAL LAYOUT F NOTES! - STANDARD LAG BOLT SPEC ASSUMES 5"18' LAG BOLTS WITH 2.5' EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS - TORQUE ALL &' HARDWARE TO THE FOLLOWING SILVER S.S. I11-16 FT-LBS BLACK S.S. 7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF POST (UPSLOPE vs. DOWNSLOPE) - FUR UNEVEN ROOF SURFACES. USE UP To TWO LEVELING SPACERS PER L FOOT OR STANDOFF. SEE DRAWING 'STANDARD RAIL LEVELING' FOR DETAILS AND LIMITATIONS SNAPNRACK RAIL STANDARD _ _ 1 SNAPNRACK SPLICE STANDARD INSERT SNAPNRACK SPLICE STANDARD BASE �tI X J' S.S. BOLTS WITH SPLIT LOCK WASHERS P *0 (3 PER SPLICE) SNAPNRACK STANDOFF CLAMP SNAPNRACK a' X 2' TYP. (OR 1.5') S.S. BOLT CHANNEL NUT WITH SPLIT LUCK WASHER SNAPNRACK STANDOFF SHAFT STANDARD (VARIOUS SIZES) ` STAINLESS LAG BOLT WITH WASHER SNAPNRACK STANDOFF BASE STANDARD I -HOLE " X I' S.S. BOLT WITH SYSTEM SHOWN WITH STANDOFF MOUNTING SPLIT LOCK WASHER COMPATIBLE WITH ALL ROOF TYPES USE FLASHED L FOOT FOR FASTER INSTALLATION ON COMPOSITION SHINGLE ROOFS GAP RAILS 0.1-9.r' FOR EXPANSION ASSEMBLED SYSTEM (SOLAR PANELS NOT SHOWN: SNAPNRACK COMPOSITION L FOOT SNAPNRACK CHANNEL NUT SHAPMRACK STANDARD RAIL SMAPNRACK COMPDSI ION RLpF FLASe-i]NG `�� SNARPlACK L FOOT BASE SEAL PENETRATION AND UNDER BASE WITH APPROPRIATE ROOF SEALANT RAFTER rYP. J' S.S. LAG SCREW WITH FLAT WASHER (SEE ENGINEERING DOCUMENTS FUR BOLT EMBEDMENT REQUIREMENTS - 2-5' MIN. EMBEDMENT IS TYPICAL) x V S.S. BOLT AND PLLfIT WASHER R — S.S. FLANGE NUT ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WI IN LOW TO MODERATE TILT RAILS CAN BE LEVELED NIP TO 3' USING UP TO TWO LEVELING SPACERS AS SHOWN IN 'SERIES I09 RAIL LEVELING' HE+NST9n. NOTES. - LAG WILTS MUST EMBED IN ROOF STRDETURAL MEMBERS/RAFTERS TORQUE ALL WLW HARDWARE TO THE FULLOWING - SILVER S.S. ID-16 FT -LIPS - BLACK S.S. 7-9 FT -LIPS - RAILS CAN MOUNT TO EITHER SIDE OF L FOOT ttPSLOPE VS DDWNSLDPE7 STEP 3� PLACE L FOOT ON TOP OF FLASHING AND TIGHTEN NUT STEP 2. SLIP FLASHING OVER L FOOT BASE STEP 1- BOLT L FDO D-L To RUQF +rIT,; LAG BOLT ROOF DECKING TYP. COLETL4 lt;St PLLA[lUN DESIGNER G. MCPHEETERS SUYE DNS PART • REv 'U G. NCPHEETERS DAT'IP ITtD1D PEN-D01 PEN DETAIL Qi FLASHED L FOOT C ,•.,.nsmu �®�,'�' a rLanc 1®`fn A-�ie. 1�Lo+c at 4P nEIGrH -f.g� W P�-RS' - wL [GHT• ra +bwy`."ts'n�gr�,(x .eaVe nenf.`iu.,x +Harr �r �uwr rs�nwn we nrwna -ar a—Oai wMr�fur Ncf +� wa STANDARD SERIES NOD ATTACHMENTS FEATURE 3' OF VERTICAL ADJUSTABIL I TY ON ALL MOUNTING POINTS WITH THE USE OF I' LEVELING SPACERS THE FIRST INCH OF ADJUSTABILITY IS ACCOMPLISHED WITH SLIDING FEATURES BUILT INTO BOTH L FOOT AND STANDOFF CLAMP COMPONENTS FOR AN ADDITIONAL INCH OF HEIGHT ADJUSTMENT, ADD UK LEVELING SPACER. USE OF SINGLE LEVELING SPACER NOT TO EXCEED 3aY.. OF ATTACHMENT POINTS. FOR A SECOND ADDITIONAL INCH OF HEIGHT ADJUSTMENT, ADD ANOTHER LEVELING SPACER. USE OF TWO LEVELING SPACERS NOT TO EXCEED 102 OF ATTACHMENT POINTS. THE LIMITS ABOVE APPLY WHEN YOU ARE AT THE KUIMUM STANDOFF HEIGHT DEPENDING ON THE STANDOFF BASE BEING USED. FOR STANDOFFS ON L FOOT BASES, THE MAXIMUM STANDOFF HEIGHT (BEFORE APPLYING THE LIMITATIONS ABOVE) IS 3'. FOR STANDOFFS ON STANDOFF BASES, THE MAXINUH HEIGHT BEFORE APPLYING THE LIMITATIONS ABOVE IS W. AXIUM SOLAR 1005 PLACID AVE. 1855) 633-8680 SUITE 100 (972) 633-8680 PLANO, TX 75074 WWW.AXIUMSOLAR.COM For Reference Only Refer to separate, stamped engineering report and calculations for roof mounting. PROJECT: C.D. PEEBLES SOLAR PV SYSTEM ADDRESS: 1604 DEVON COURT SOUTHLAKE, TX 76092 REVISIONS TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 30OW MODULES (1) SOLAREDGE 7.6KW INVERTER(S) SNAPNRACK SERIES 100 RACKING 400 & ----0 TILT(S) 2750 & 1850 ORIENTATION(S) Utility Meter. ESI ID# ? DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE CONSTRUCTION ATTACHMENT DETAIL *' ` a sT F G.M`PNE F RT DNs `A"'' I SERIES 100 ASSEMBLY DETAILS UEC I" ^'°'d RAPPER. G. M(PHEFTERS DATE IZDIIT 5100 Df)3 E .�.,.". DC'SIGMER G.MM:PHEETERS 2% 101 PAN'= I SERIES 100 RAIL LEVELING IREV e...a.. RAFTER G_MFPHBETERS DATIe I�DD1T 5106 DO6 PV 103 idth (1 each) HT # 596-00241, roll, custom printed fields, (qty. 1) 11.3 400 400 15 INVERTER 1 LABELING HT # 558-00312, Continuous, Red Vinyl, 2" width (5 each) DC ]-BOX LABELING 71 F 5`Jb-VU4yb, ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT HT # 596-00588, pre-printed, (qty. 1) ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED DC Raceways (every 10', every turn, above and below penetrations) - (AR) 1" x 9" WARNING: PHOTOVOLTAIC POWER SOURCE HT # 596-00499, roll, pre-printed, (qty. 1) A WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL HT # 596-00495, roll, pre-printed, (qty. 1) CE EM TIE-IN PANEL HT # 596-00588, pre-printed, (qty. 2) ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ALL DC JUNCTION BOXES/SOLADECKS PVLables.com p/n 05-112, pre-printed, (qty. 1) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN 3301-RR ELECTFIC PY PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY i HT # 596-00497, roll, pre-printed, (qty. 1) WARNING HT # 596-00239, roll, pre-printed, (qty. 1) ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. 32 TERMINALS ON BOTH LINE AND 24o LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAIN PV DISCONNECT LABELING HT # 596-00633, White with Orange Warning Header, 4" height, 6" N WARNIN 7rA WER TO THIS SERVICE EQUIPMENT IS ALSO SUPPLIED BY ON -SITE SOLAR SYSTEMS DISCONNECT LOCATED WITHIN 10 FEET OF METER METER BASE / TRANSFORMER POLE LABELING idth A WARNING _& THIS TRANSFORMER IS SUPPLIED BY BOTH UTILITY AND SOLAR POWER SOURCES DISCONNECTS LOCATED ON ADJACENT BLDG MAX PV AMPS 32 A AC MAX PV VOLTS 240 V AC AXIUM SOLAR 1005 PLACID AVE. (855) 633-8680 SUITE 100 (972) 633-8680 PLANO, TX 75074 WWW.AXIUMSOLAR.COM OF 9kP ............ �BENNETi°A. FORD ° .�'.°°°°109875 Y n ° PLAINVIEW ENGINEERING LLC TX FIRM# 20680 11-11-2019; ELECTRICAL ONLY PROJECT: C.D. PEEBLES SOLAR PV SYSTEM ADDRESS: 1604 DEVON COURT SOUTHLAKE, TX 76092 REVISIONS TOTAL SYSTEM CAPACITY - 8.7 KW (29) TRINA ALLMAX 30OW (1) SOLAREDGE 7.6KW SNAPNRACK SERIES 100 RACKING 40° TILT 275° & 185° ORIENTATION(S) Utility Meter, ESI ID# ? DATE 11/5/19 PROJECT # 2609 DESIGNED BY: C. WRIGHT DRAWN BY: C. WRIGHT SCALE NONE CONSTRUCTION LABELS PV 104 39 ' 1664 Devon Couh g l4' L � - 1 t r a. r.- / it Solar PV on this roof surface (west) and adjacent roof (south) _ - -�,... „6 ����� 1 ... �� t `fit e-�ag4 �: _., t. .I 5