Loading...
Item 6ACASE NO: ZA19-0067 SOUTHLAKE PLANNING & DEVELOPMENT SERVICES STAFF REPORT December 30, 2019 PROJECT: Zoning Change and Site Plan for Carroll Dragon Stadium EXECUTIVE SUMMARY: On behalf of Carroll ISD, Hart, Gaugler and Associates is requesting approval of a Zoning Change and Site Plan for Carroll Dragon Stadium on property described as Lot 1, Block 1 and Lot 1, Block 2, Carroll ISD No. 6 Addition, an addition to the City of Southlake, Tarrant County, Texas and located at 1085 S. Kimball Avenue, Southlake, Texas. Current Zoning: "S -P-1" Detailed Site Plan District. Proposed Zoning: "S -P-1" Detailed Site Plan District. SPIN Neighborhood #8. DETAILS: VARIANCE REQUEST: ACTION NEEDED: Case No. ZA19-0067 The stadium is located at the northwest corner of Silicon Drive and S. Kimball Avenue. The purpose of this request is to seek approval of a Zoning Change and Site Plan for the construction of two (2) restrooms (approximately 215 s.f.) to the home side of Dragon Stadium. If approved by City Council, the current S -P-1 Detailed Site Plan District (Ordinance No. 480-330D) will be amended to reflect proposed increase in building footprint (215 s.f.). All other previous conditions of approval and approved zoning regulations shall remain. Landscaping — variance to Landscape Ordinance No. 544-B, Sections 3.3 and 3.4, requesting relief from additional interior landscape requirements relating to the increase in floor area and replacement of the removed ornamental tree. Site Data Summary Existing Zoning S -P-1 Land Use Designation Public/Semi-Public Lot Acreage 35.801 Existing Building Footprint Stadium Home 44,780 Proposed Building Footprint Stadium Home 44,995 Existing Impervious Coverage 69.25% Proposed Impervious Coverage 69.27% On November 21, 2019, the Planning & Zoning Commission unanimously recommended approval of this item as presented. On December 3, 2019, the City Council approved the 1s' reading (6-0) on consent. 1. Conduct Public Hearing 2. Consider approval of a Zoning Change and Site Plan ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Site Plan Review Summary No. 2, dated November 13, 2019 (D) Surrounding Property Owners Map and Responses (E) Ordinance No. 480-330E Full Size Plans (for Commission and Council members only) Presentation S -P-1 Regulations and Variance Request Letter Plans SPIN Report STAFF CONTACT: Dennis Killough (817) 748-8072 Lorrie Fletcher (817) 748-8069 Case No. ZA19-0067 BACKGROUND INFORMATION OWNER: Carroll ISD APPLICANT: Hart, Gaugler & Associates, Inc. PROPERTY SITUATION: 1085 S. Kimball Avenue LEGAL DESCRIPTION: Lot 1, Block 1, and Lot 1, Block 2, Carroll ISD No. 6 Addition LAND USE CATEGORY: Public/Semi-Public CURRENT ZONING: "S -P-1" Detailed Site Plan District PROPOSED ZONING: "S -P-1" Detailed Site Plan District HISTORY: -City Council approved the zoning and site plan for Dragon Stadium on March 7, 2000 (ZA99-132). -A final plat was approved on February 3, 2000. -City Council approved a revised zoning and site plan for Dragon Stadium on March 18, 2003 to accommodate games for the Dallas Burn soccer team (ZA03-005). -City Council approved a revised zoning and site plan for Dragon Stadium on Sept. 2, 2003 to remove the requirements for a bufferyard and a screening device on the west side of the property adjacent to Mr. Kaposta's property (ZA03-057). -City Council approved a zoning change and site plan from "S -P-1" Detailed Site Plan District to "S -P-1" Detailed Site Plan District to add 1,600 seats to the home side of the stadium and to repave a portion of the existing parking lot, adding approximately 137 spaces. Also approved were additions to the concessions and restrooms and the construction of a new Disaster Recovery Center, which added approximately 4,350 square feet of floor area at the site. (ZA09-057). -City Council approved a zoning change and site plan from "S -P-1" Detailed Site Plan District to "S -P-1" Detailed Site Plan District to allow pavement for 18 additional bus parking spaces and the addition of an approximately 1,200 square foot storage building for tire storage at Dragon Stadium. (ZA18-032). SOUTHLAKE 2035 PLAN: Consolidated Future Land Use Plan The underlying land use designation is Public/Semi-Public. The existing stadium and the proposed change in zoning are consistent with this designation. Case No. ZA19-0067 Mobility and Master Thoroughfare Plan The Master Thoroughfare Plan recommends S. Kimball Ave. to be a 4 - lane divided arterial street with 88 feet of right-of-way. Adequate right-of- way has been dedicated for this roadway. Pathways Master Plan & Sidewalk Plan There are existing sidewalks along S. Kimball Ave. and Silicon Drive adjacent to the site. Attachment A Page 1 TRANSPORTATION ASSESSMENT: A TIA is not required for the addition. TREE PRESERVATION: There is approximately 9.6% of existing tree cover on the site. The applicant is proposing to remove one (1) tree without mitigation resulting in approximately 99.6% tree preservation. CITIZEN INPUT/ BOARD REVIEW: A SPIN meeting was held October 22, 2019. PLANNING & ZONING COMMISSION: November 21, 2019; Approved (6-0) subject to the Staff Report dated November 15, 2019 and Site Plan Review Summary No. 2, dated November 13, 2019, granting the requested variance and tree preservation as presented. CITY COUNCIL: December 3, 2019; Approved 1s` reading (6-0) on consent. STAFF COMMENTS: Attached is Site Plan Review Summary No. 2, dated November 13, 2019. The criteria for the City Council to grant a variance to Landscape Ordinance No. 544-B are below: Landscape Ordinance No. 544-B: 12.2 VARIANCES AND APPEALS: Any applicant who desires a variance or elimination of the requirements herein, or who desires to appeal a decision by the Landscape Administrator, shall file a written appeal with the City Manager for consideration by the City Council. Such appeal shall be accompanied by adequate graphic reproductions, a written summary of the request, and justification for such request. The City Council shall have the authority to grant an interpretation or variance to the requirements of this ordinance. In granting any variance, the City Council shall determine that a literal enforcement of the regulations herein will create an unnecessary hardship or a practical difficulty on the applicant, that the situation causing the unnecessary hardship or practical difficulty is unique to the affected property and is not self-imposed, that the variance will not injure and will be wholly compatible with the use and permitted development of adjacent properties, and that the granting of the variance will be in harmony with the spirit and purpose of this ordinance. The decision of the City Council shall be final. Case No. Attachment A ZA19-0067 Page 2 Vicinity Map Dragon Stadium � � | ■ / Bm| § § § � ■ - ` 710 13 --11 Q% " INDUSTRIAL BLVE) 71 &\ !§ \ � . % ^ % ®LAV ; - 7 % - 3 0 � Eco o _ . � � . 2 � 9 � r �.- - \~ ; ZAg9-OO&7 Zoning Change & Site Plan D 60D 17m 2140D Feet Case No. Attachment B ZA19- O67 Page SITE PLAN REVIEW SUMMARY Case No.: ZA19-0067 Review No.: Two Date of Review: 11/13/19 Project Name: Zoning Change & Site Plan — Dragon Stadium APPLICANT: Hart, Gaugler & Associates John Blacker 12801 N. Central Expressway Dallas, TX Phone: 972-239-5111 Email: jblacker@hartgaugler.com OWNER: Carroll ISD John Haugen 2400 N. Carroll Avenue Southlake, TX Phone: 832-651-1688 Email: john.haugen@southlakecarroll.edu CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 11/4/19 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT THE APPROPRIATE STAFF MEMBER. Planning Review Lorrie Fletcher Planner Phone: (817) 748-8069 Email: Ifletcher a@ci.southlake.tx.us 1. The Site Plan must conform to the underlying zoning. Except as noted in the current submittal, all previous plans and conditions of the "S -P-1" zoning conditions of approval remain in effect. 2. The applicant has requested relief from any interior landscaping requirements. Variance Requested * Please be aware when submitting for a building permit, any variation from the approved site plan, elevations and associated plans will require a zoning change. * All development must comply with the underlying zoning district regulations. * The submitted elevations indicate use of EIFS building material. A variance to masonry requirements set forth in Zoning Ordinance No. 480 and Masonry Ordinance No. 557 is exempted by HB 2439, 86th Legislature. Tree Conservation/Landscape Review Keith Martin Landscape Administrator Phone: (817) 748-8229 E-mail: kmartin(a)ci.south lake.tx.us TREE CONSERVATION COMMENTS: 1. The applicant is proposing to remove one (1) ornamental Pear tree for the construction of the proposed restroom addition. The tree is approximately 10" diameter and was planted as part of Case No. Attachment C ZA19-0067 Page 1 the original stadium construction landscape requirements. LANDSCAPE COMMENTS: The building footprint area of the proposed addition is less than 5,000 square feet, and 30% of the existing building footprint. Only landscaping is required for 30% of the proposed addition building footprint area. 215 square feet. Existing buildings: Buildings in existence on the effective date of this ordinance shall be considered legally nonconforming as it pertains to this ordinance. New construction greater in size than 30% of the existing building or greater than 5,000 square feet shall require compliance with this ordinance as it applies to the entire square footage of the existing building and proposed addition. New construction intended to increase the square footage by less than 30% of the existing building or less than 5,000 square feet shall be required to meet the requirements herein only as it pertains to the square footage of the new construction. 2. A Landscape Plan which reflects the additional landscaping required for the proposed building addition is required. A variance has been requested for relief from landscape requirements. Public Works/Engineering Review Steve Anderson, P.E., CFM Deputy City Engineer Phone: (817) 748-8101 E-mail: sanderson(o-)ci.southlake.tx.us GENERAL COMMENTS: 1. This review is preliminary. Additional requirements may be necessary with the review of civil construction plans. C4.0 Water line needs to be either 1" or 2". 1 '/2" service is not allowed. Fire Department Review Kelly Clements Fire Marshal Phone: (817) 748-8233 E-mail: kclements(o-)ci.south lake.tx.us No comments based on the submitted information. Case No. Attachment C ZA19-0067 Page 2 General Informational Comments: A SPIN meeting for this project was held October 22, 2019. No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. All mechanical equipment must be screened of view rights-of-way and residential properties in accordance with the Zoning Ordinance No. 480, as amended. All lighting must comply with the Lighting Ordinance No. 693, as amended. All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. It appears that this property lies within the 65 LDN D/FW Regional Airport Overlay Zone and will require construction standards that meet requirements of the Airport Compatible Land Use Zoning Ordinance No. 479. Through the wholesale water customer contract with the City of Fort Worth, all new water connections are required to pay the City of Fort Worth impact fee. The City of Fort Worth impact fee assessment is based on the final plat recordation date and building permit issuance. The applicant is encouraged to review the City of Fort Worth's assessment and collection of Impact Fees Guide to determine the fee amount. Development must comply with all requirements in Zoning Ordinance No. 480, Section 43, Overlay Zones. Masonry materials shall mean and include brick, stucco, plaster, cement, concrete tilt wall, stone, rock or other masonry material of equal characteristics. Stucco and plaster shall only be considered a masonry material when applied using a 3 -step process over diamond metal lath mesh to a 7/8th inch thickness or by other processes producing comparable cement stucco finish with equal or greater strength and durability specifications. Synthetic products (e.g., EIFS —exterior insulation and finish systems, hardi plank, or other materials of similar characteristics) shall not be considered a masonry material. The submitted elevations indicate use of EIFS building material. A variance to masonry requirements set forth in Zoning Ordinance No. 480 and Masonry Ordinance No. 557 is exempted by HB 2439, 861 Legislature. Development must comply with all requirements in Zoning Ordinance No. 480, Section 33.21, Building Color Standards for Non -Residential Buildings. The applicant should be aware that prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. Denotes Informational Comment Case No. Attachment C ZA19-0067 Page 3 SURROUNDING PROPERTY OWNERS MAP & RESPONSES 1. Owner's Name PEARSON, CAREY Zoning SF1-A Physical Address 695 S KIMBALL AVE Acreage 2.08 Response NR 2. PEARSON, CAREY SF1-A 2300 CROOKED LN 2.22 NR 3. MARX, RODERICK SF1-A 2350 CROOKED LN 2.30 NR 4. MULLER, RICHARD J SF1-A 2400 CROOKED LN 2.16 NR 5. BEECH, EDNA E SF1-A 701 WHISPERING WOODS CIR 1.94 NR 6. KTR DFW LLC 11 1100 S KIMBALL AVE 11.20 NR 7. LLC SIMPLY STORAGE SOUTHLAKE 11 950 S KIMBALL AVE 1.32 NR 8. ESPREE ANIMAL PRODUCTS INC 11 1070 S KIMBALL AVE 24.75 NR 9. MORRISON, PAMELA SF1-A 710 WHISPERING WOODS CIR 2.25 NR 10. STRUEMPLER, LORIE LEE SF1-A 720 WHISPERING WOODS CIR 1.94 NR 11. KENDRICK, MICKY D SF1-A 2401 CROOKED LN 1.28 NR 12. CUNDIFF, JOHN E SF1-A 2317 CROOKED LN 0.85 NR 13. CHARLESTON COURT LP 01 530 SILICON DR 4.85 NR 14. CARROLL, ISD SPI 601 SILICON DR 4.11 NR 15. CENTERSTONE HEIGHTS LLC 11 2815 EXCHANGE BLVD 1.76 NR 16. BHS VENTURES LLC 11 2271 E CONTINENTAL BLVD 1.41 NR Case No. Attachment D ZA19-0067 Page 1 17. SLM PROPERTIES LLC 11 2273 E CONTINENTAL BLVD 1.41 NR 18. CORNERSTONE WEALTH MGT LLC 11 2273 E CONTINENTAL BLVD 1.41 NR 19. COGENT POINT LLC 11 2275 E CONTINENTAL BLVD 1.41 NR 20 WESTGATE OFFICE PARK OWNERS 11 2271 E CONTINENTAL BLVD 1.41 NR 21. COGENT POINT LLC 11 2275 E CONTINENTAL BLVD 1.41 NR 22. COGENT POINT LLC 11 2275 E CONTINENTAL BLVD 1.41 NR 23. KAWASAKI MOTORS CORP USA 11 925 S KIMBALL AVE 3.82 NR 24. KAPOSTA, AMERICA AG 2311 CROOKED LN 3.03 NR 25. SOUTHLAKE SIGNS INC SP2 2300 DEAN WAY 2.29 NR 26. LEGENDS SLTX 2320 LLC SP2 2320 DEAN WAY 2.45 NR 27. CARROLL, ISD SP1 1085 S KIMBALL AVE 35.41 NR 28. WERX PROPERTY HOLDINGS LLC SP2 2380 DEAN WAY 1.52 NR 29. SMS LEGENDS 2360 LLC SP2 2360 DEAN WAY 1.79 NR 30. Superintendent of Carroll ISD NR 31. Superintendent of Grapevine Colleyville ISD NR 32. Superintendent of Northwest ISD NR 33. Superintendent of Keller ISD NR 34. City of Grapevine NR Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Thirty-four (34) Responses received: None (0) Case No. Attachment D ZA19-0067 Page 2 CITY OF SOUTHLAKE, TEXAS ORDINANCE NO. 480-330E AN ORDINANCE AMENDING ORDINANCE NO. 480, AS AMENDED, THE COMPREHENSIVE ZONING ORDINANCE OF THE CITY OF SOUTHLAKE, TEXAS; GRANTING A ZONING CHANGE ON A CERTAIN TRACT OR TRACTS OF LAND WITHIN THE CITY OF SOUTHLAKE, TEXAS BEING LEGALLY DESCRIBED AS LOT 1, BLOCK 1, AND LOT 1, BLOCK 2, CARROLL I.S.D. NO. 6 ADDITION, AND BEING 41.347 ACRES, AND MORE FULLY AND COMPLETELY DESCRIBED IN EXHIBIT "A" FROM "S -P-1" DETAILED SITE PLAN DISTRICT WITH "CS" COMMUNITY SERVICE DISTRICT USES INCLUDING TRANSPORTATION FACILITY AND STADIUM TO "S -P-1" DETAILED SITE PLAN DISTRICT WITH "CS" COMMUNITY SERVICE DISTRICT USES INCLUDING TRANSPORTATION FACILITY AND STADIUM, AS DEPICTED ON THE APPROVED SITE PLAN ATTACHED HERETO AND INCORPORATED HEREIN AS EXHIBIT "B", SUBJECT TO THE SPECIFIC REQUIREMENTS CONTAINED IN THIS ORDINANCE; CORRECTING THE OFFICIAL ZONING MAP; PRESERVING ALL OTHER PORTIONS OF THE ZONING ORDINANCE; DETERMINING THAT THE PUBLIC INTEREST, MORALS AND GENERAL WELFARE DEMAND THE ZONING CHANGES AND AMENDMENTS HEREIN MADE; PROVIDING THAT THIS ORDINANCE SHALL BE CUMULATIVE OF ALL ORDINANCES; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR A PENALTY FOR VIOLATIONS HEREOF; PROVIDING A SAVINGS CLAUSE; PROVIDING FOR PUBLICATION IN THE OFFICIAL NEWSPAPER; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, the City of Southlake, Texas is a home rule City acting under its Charter adopted by the electorate pursuant to Article XI, Section 5 of the Texas Constitution and Chapter 9 of the Texas Local Government Code; and, WHEREAS, pursuant to Chapter 211 of the Local Government Code, the City has the authority to adopt a comprehensive zoning ordinance and map regulating the location and use of buildings, other structures and land for business, industrial, residential and other purposes, and to amend said ordinance and map for the purpose of promoting the public health, safety, morals and general welfare, all in accordance with a comprehensive plan; and WHEREAS, the hereinafter described property is currently zoned as "S -P-1" Detailed Site Plan District with "CS" Community Service District uses including transportation facility and Page 1 stadium under the City's Comprehensive Zoning Ordinance; and WHEREAS, a change in the zoning classification of said property was requested by a person or corporation having a proprietary interest in said property; and WHEREAS, the City Council of the City of Southlake, Texas, at a public hearing called by the City Council did consider the following factors in making a determination as to whether these changes should be granted or denied: safety of the motoring public and the pedestrians using the facilities in the area immediately surrounding the sites; safety from fire hazards and damages; noise producing elements and glare of the vehicular and stationary lights and effect of such lights on established character of the neighborhood; location, lighting and types of signs and relation of signs to traffic control and adjacent property; street size and adequacy of width for traffic reasonably expected to be generated by the proposed use around the site and in the immediate neighborhood; adequacy of parking as determined by requirements of this ordinance for off-street parking facilities; location of ingress and egress points for parking and off-street loading spaces, and protection of public health by surfacing on all parking areas to control dust; effect on the promotion of health and the general welfare; effect on light and air; effect on the over -crowding of the land; effect on the concentration of population, and effect on transportation, water, sewerage, schools, parks and other public facilities; and, WHEREAS, the City Council of the City of Southlake, Texas, further considered among other things the character of the districts and their peculiar suitability for particular uses and the view to conserve the value of the buildings, and encourage the most appropriate use of the land throughout this City; and, WHEREAS, the City Council of the City of Southlake, Texas, does find that there is a public necessity for the zoning changes, that the public demands them, that the public interest clearly requires the amendments, and that the zoning changes do not unreasonably invade the rights of Page 2 those who bought or improved property with reference to the classification which existed at the time their original investment was made; and, WHEREAS, the City Council of the City of Southlake, Texas, does find that the changes in zoning lessen the congestion in the streets, helps secure safety from fire, panic, and other dangers, promotes the health and the general welfare, provides adequate light and air, prevents the over -crowding of land, avoids undue concentration of population, and facilitates the adequate provision of transportation, water, sewerage, schools, parks and other public requirements; and, WHEREAS, the City Council of the City of Southlake, Texas, has determined that there is a necessity and need for the changes in zoning and has also found and determined that there has been a change in the conditions of the property surrounding and in close proximity to the tract or tracts of land requested for a change since the tract or tracts of land were originally classified and therefore feels that the respective changes in zoning classification for the tract or tracts of land are needed, are called for, and are in the best interest of the public at large, the citizens of the city of Southlake, Texas, and helps promote the general health, safety and welfare of the community. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS: SECTION 1. That Ordinance No. 480, the Comprehensive Zoning Ordinance of the City of Southlake, Texas, passed on the 19th day of September, 1989, as originally adopted and amended, is hereby amended so that the permitted uses in the hereinafter described areas be altered, changed and amended as shown and described below: Being described as Lot 1, Block 1, and Lot 1, Block 2, Carroll I.S.D. No. 6 Addition, an addition to the City of Southlake, Tarrant County, Texas, according to the plat recorded in Cabinet A, Slides 6413 & 6414, Plat Records, Tarrant County, Texas, and being approximately 41.347 acres, and more fully and completely described in Exhibit "A" from "S -P-1" Detailed Site Plan District with "CS" Community Service District uses including transportation facility and stadium to "S -P-1" Detailed Site Plan Page 3 District with "CS" Community Service District uses including transportation facility and stadium as depicted on the approved Site Plan attached hereto and incorporated herein as Exhibit "B", and subject to the specific conditions established in the motion of the City Council and attached hereto and incorporated herein as Exhibit "C." SECTION 2. That the City Manager is hereby directed to correct the Official Zoning map of the City of Southlake, Texas, to reflect the herein changes in zoning. SECTION 3. That in all other respects the use of the tract or tracts of land herein above described shall be subject to all the applicable regulations contained in said Zoning Ordinance and all other applicable and pertinent ordinances for the City of Southlake, Texas. All existing sections, subsections, paragraphs, sentences, words, phrases and definitions of said Zoning Ordinance are not amended hereby, but remain intact and are hereby ratified, verified, and affirmed. SECTION 4. That the zoning regulations and districts as herein established have been made in accordance with the comprehensive plan for the purpose of promoting the health, safety, morals and the general welfare of the community. They have been designed, with respect to both present conditions and the conditions reasonably anticipated to exist in the foreseeable future; to lessen congestion in the streets; to provide adequate light and air; to prevent over -crowding of land; to avoid undue concentration of population; and to facilitate the adequate provision of transportation, water, sewerage, drainage and surface water, parks and other commercial needs and development of the community. They have been made after a full and complete hearing with reasonable consideration among other things of the character of the district and its peculiar suitability for the particular uses and with a view of conserving the value of buildings and encouraging the most appropriate use of land throughout the community. SECTION 5. Page 4 That this ordinance shall be cumulative of all other ordinances of the City of Southlake, Texas, affecting zoning and shall not repeal any of the provisions of said ordinances except in those instances where provisions of those ordinances are in direct conflict with the provisions of this ordinance. SECTION 6. That the terms and provisions of this ordinance shall be deemed to be severable and that if the validity of the zoning affecting any portion of the tract or tracts of land described herein shall be declared to be invalid, the same shall not affect the validity of the zoning of the balance of said tract or tracts of land described herein. SECTION 7. Any person, firm or corporation who violates, disobeys, omits, neglects or refuses to comply with or who resists the enforcement of any of the provisions of this ordinance shall be fined not more than Two Thousand Dollars ($2,000.00) for each offense. Each day that a violation is permitted to exist shall constitute a separate offense. SECTION 8. All rights and remedies of the City of Southlake are expressly saved as to any and all violations of the provisions of Ordinance No. 480, as amended, or any other ordinances affecting zoning which have accrued at the time of the effective date of this ordinance; and, as to such accrued violations and all pending litigation, both civil and criminal, whether pending in court or not, under such ordinances, same shall not be affected by this ordinance but may be prosecuted until final disposition by the courts. SECTION 9. The City Secretary of the City of Southlake is hereby directed to publish the proposed Page 5 ordinance in its entirety on the City website together with a notice setting out the time and place for a public hearing thereon at least ten (10) days before the second reading of this ordinance, and it this ordinance provides for the imposition of any penalty, fine or forfeiture for any violation of any of its provisions, then the City Secretary shall additionally publish this ordinance in the official City newspaper one time within ten (10) days after passage of this ordinance, as required by Section 3.13 of the Charter of the City of Southlake. SECTION 10. This ordinance shall be in full force and effect from and after its passage and publication as required by law, and it is so ordained. PASSED AND APPROVED on the 1 It reading the day of December, 2019. 1/- •C ATTEST: CITY SECRETARY PASSED AND APPROVED on the 2nd reading the day of January, 2020. MAYOR ATTEST: CITY SECRETARY Page 6 APPROVED AS TO FORM AND LEGALITY: CITY ATTORNEY DATE: ADOPTED: EFFECTIVE: Page 7 EXHIBIT "A" Being legally described as Lot 1, Block 1, and Lot 1, Block 2, Carroll I.S.D. No. 6 Addition, an addition to the City of Southlake, Tarrant County, Texas, according to the plat recorded in Cabinet A, Slides 6413 & 6414, Plat Records, Tarrant County, Texas, and being approximately 41.347 acres. Page 8 EXHIBIT "B" SITE PLAN APPROVED WITH ORDINANCE NO. 480-330 Page 9 5HIM-4 IIS I' �I M110011131 M1101111o0 1112111 HIM go 00000 IBM Page 9 5HIM-4 Page 9 e � r CARROLL INDEPENDENT SCHOOL DISTRICT 1 , - •may ATHLETIC STADIUM _ SOUIHLAKE.TEXAS Page 10 S -P-1 DEVELOPMENT REGULATIONS APPROVED WITH ORDINANCE NO. 480-330 SP 1 DEVELOPMENT REGULATIONS SITE PLAN DEVELOPMENT FOR CARROLL I.S.D. STADIUM SITE Permitted Uses: a. Outdoor sports stadium (includes track and field), offices, meeting rooms, concession stands, and sanitary facilities. b. Bus parking and storage. c. Bus mechanical maintenance. d. Private (not for resale) petroleum operations: fuel storage and dispensing other petroleum related issues in character with vehicle maintenance and refueling. e. Signage appropriate for site. f. Other uses as approved in CS zoning. Site plan: Actual construction and usage shall be as shown on site plan as approved by P&Z and City Council. Development Regulations: 1. Building maximum height limitation — 85 feet. 2. Building setback - Front yard 30 feet at S. Kimball Ave., side, and rear yards to be 25 feet_ 3. Maximum lot coverage: Building or structure footprint not to exceed 60%. 4. Maximum impervious coverage not to exceed 95%. 5. No additional development regulations provided for residential adjacency. 6. Buffer yards -- width and type as shown on approved site plan. 7. Landscape: a. Interior landscape for parking lots to be 20 sq.ft. per provided parking space. b. No landscape area to be provided for seasonal color. c. Landscaping and/or ground cover to be provided at periphery of stadium and other buildings. 8. Parking: a. Seating to Parking ratio — 5:1 for stadium. b. Parking for bus maintenance to be as shown on site plan. Page 11 SITE PLAN APPROVED WITH ORDINANCE NO. 480-330A ' Q S -p u Fin 6© x C�L I z 0=) .. ............ . 4 -AL ...... - LL Z EL X, iFl, Amw MDZ.VW .. . . ........ 0. CA col IX— m LU iio c" 5 ILL) AI . 44 q , -ccz 4� IN.... . .. . . ...... j cL F- 1 , OF - 8 Lzu L'u Lcu, o UIZLU TMz 'T LU Ui Lu 0 N EL SNA Wi Rn Rn Page 12 J- 1. V" ' Q S -p u Fin 6© x C�L I z 0=) .. ............ . 4 -AL ...... - LL Z EL X, iFl, Amw MDZ.VW .. . . ........ 0. CA col IX— m LU iio c" 5 ILL) AI . 44 q , -ccz 4� IN.... . .. . . ...... j cL F- 1 , OF - 8 Lzu L'u Lcu, o UIZLU TMz 'T LU Ui Lu 0 N EL SNA Wi Rn Rn Page 12 y 4g Ito D ' Q S -p u Fin 6© x C�L I z 0=) .. ............ . 4 -AL ...... - LL Z EL X, iFl, Amw MDZ.VW .. . . ........ 0. CA col IX— m LU iio c" 5 ILL) AI . 44 q , -ccz 4� IN.... . .. . . ...... j cL F- 1 , OF - 8 Lzu L'u Lcu, o UIZLU TMz 'T LU Ui Lu 0 N EL SNA Wi Rn Rn Page 12 y 4g ' Q S -p u Fin 6© x C�L I z 0=) .. ............ . 4 -AL ...... - LL Z EL X, iFl, Amw MDZ.VW .. . . ........ 0. CA col IX— m LU iio c" 5 ILL) AI . 44 q , -ccz 4� IN.... . .. . . ...... j cL F- 1 , OF - 8 Lzu L'u Lcu, o UIZLU TMz 'T LU Ui Lu 0 N EL SNA Wi Rn Rn Page 12 S -P-1 DEVELOPMENT REGULATIONS APPROVED WITH ORDINANCE NO. 480-330A SP 1 DEVELOPMENT REGULATIONS SITE PLAN DEVELOPMENT FOR CARROLL I.S.D. STADIUM SITE Permitted Uses: 1. Outdoor sports stadium (includes track and held), offices, meeting rooms, concession stands, and sanitary facilities. 2. Bus parking and storage. Bus mechanical maintenance. 4. Private (not for resale) petroleum operations: fuel storage and dispensing other petroleum related issues in character with vehicle maintenance and refueling. Other uses as approved in CS zoning. Tents, portable ticket booths, and portable toilets shall be permitted in accordance with the attached site plan and all applicable building and fire codes. These structures may not be erected prior to April 1st and must be removed by December 15th of each calendar year. Site plan: Actual construction and usage shall be as shown on site plan as approved by P&Z and City Council. Development Regulations: Building maximum height limitation -85 feet. 2. Building setback -Front yard 30 feet at S. Kimball. Ave., side, and rear yards to be 25 feet. Maximum lot coverage: Building or structure footprint not to exceed 60%. 4. Maximum impervious coverage not to exceed 95%P. No additional development regulations provided for residential adjacency. 6. Buffer yards -width and type as shown on approved site plan. Landscape: a. interior landscape for parking lots to be 20 sq.ft. per provided parking space. b. No landscape area to be provided for seasonal color. C. Landscaping and/or ground cover to be provided at periphery of stadium and other buildings. Page 13 8. The maximum stadium seating shall not exceed 9,300 seats. 9. Parking: a. Parking for bus maintenance to be as shown on site plan. b. Gravel will be permitted as an acceptable surface material for the 497 parking spaces in the northwest portion of the site as shown on the attached site plan. Gravel must be treated to prevent dust. c. The existing transportation bus lot may be utilized for an additional 469 parking spaces subject to the condition that all buses shall be relocated to an appropriate location suitable for bus storage the day prior to a game. d. The minimum on-site number of parking spaces provided for stadium seating shall be no less than 2,541 parking spaces for all stadium events. e. The maximum seating to parking space ratio provided on-site shall be no more than 3.66:1. f. 444 off-site parking spaces shall be allocated for employee parking at Eubanks Intermediate School and Dawson Middle School for use during all stadium events. g. The maximum seating to parking space ratio provided on-site and off-site shall be no more than 3.12:1. Page 14 SITE PLAN APPROVED WITH ORDINANCE NO. 480-3306 U w L in LL m p".3170 lrk ui —j 1I r11a.Y SII !j: m Ld Cc t.. 709 OW JAP; ollow is. < Z i�v ol ILL, --a7 MT!, -nowl. 4 1 "LIU + Lmwum lati lillujull, ill !RuLpAiI LLILLLUI w F- JLU _Uz McgQ LLI w LuE2= o 5,< 13- It h9i 5 N AI As— LU U Wfw L 7 z - uj WM X LL cnz EL LL LL m p".3170 lrk ui —j 1I r11a.Y SII !j: m Ld Cc t.. 709 OW JAP; ollow is. < Z i�v ol ILL, --a7 MT!, -nowl. 4 1 "LIU + Lmwum lati lillujull, ill !RuLpAiI LLILLLUI w F- JLU _Uz McgQ LLI w LuE2= o 5,< 13- It h9i 5 N AI As— I U Wfw L 7 I U Wfw 7 cnz Page 15 S -P-1 DEVELOPMENT REGULATIONS APPROVED WITH ORDINANCE NO. 480-3306 SP 1 DEVELOPMENT REGULATIONS SITE PLAN DEVELOPMENT FOR CARROLL I.S.D. STADIUM SITE Permitted Uses: 1. Outdoor sports stadium (includes track and field), offices, meeting rooms, concession stands, and sanitary facilities. 2. Bus parking and storage. 3. Bus mechanical maintenance. 4. Private (not for resale) petroleum operations: fuel storage and dispensing other petroleum related issues in character with vehicle maintenance and refueling. 5. Other uses as approved in CS zoning. Tents, portable ticket booths, and portable toilets shall be permitted in accordance with the attached Site plan and all applicable building and fire codes. These structures may not be erected prior to April 1 st and must be removed by December 15th of each calendar year. Site plan: Actual construction and usage shall be as shown on site plan as approved by P&Z and City Council. Development Regulations: Building maximum height limitation -85 feet. Building setback -Front yard 30 Feet at S. Kimball Ave., side, and rear yards to be 25 feet. Maximum lot coverage: Building or structure footprint not to exceed 60%v, 4. Maximum impervious coverage not to exceed 95%. No additional development regulations provided for residential adjacency. 6. Buffer yards -width and type as shown on approved site plan. 7. Landscape: a. Interior landscape for parking lots to be 20 sq.ft. per provided parking space. b. No landscape area to be provided for seasonal color. C. Landscaping and/or ground cover to be provided at periphery of stadium and other buildings. Page 16 8. The maximum stadium seating shall not exceed 9,300 seats. 9_ Parking: a. Parking for bus maintenance to be as shown on site plan_ b. Gravel will be permitted as an acceptable surface material for the 497 parking spaces in the northwest portion of the site as shown on the attached site plan. Gravel must be treated to prevent dust. c. The existing transportation bus lot may be utilized for an additional 469 parking spaces subject to the condition that all buses shall be relocated to an appropriate location suitable for bus storage the day prior to a game. J. The minimum on-site number of parking spaces provided for stadium seating shall be no less than 2,541 parking spaces for all stadium events. e. The maximum seating to parking space ratio provided on-site shall be no more than 3.66:1. f. 444 off-site parking spaces shall be allocated for employee parking at Eubanks Intermediate School and Dawson Middle School for use during all stadium events. g. The maximum seating to parking space ratio provided on-site and off-site shall be no more than 3.12:1. Page 17 SITE PLAN APPROVED WITH ORDINANCE NO. 480-330C Repaving parking ll� in shaded area Adding 1,600 seats to home side EMS - Page 18 S -P-1 DEVELOPMENT REGULATIONS APPROVED WITH ORDINANCE NO. 480-330C H A Hart, Gaugler & Assoclate,�. lite. c. I & Structural Engineerltng A Q November 23, 2009 Mr. Dennis Killough City of Southlake Department of Planning 1400 Main Street, Suite 310 Southlake, TX 76092 Re: Carroll Independent School District Dragon Stadium Addition — Zoning Narrative HGA Project Number 209136 Dear Dennis: Carroll ISD desires to add 1,600 seats to the home side of Dragon Stadium located at 1085 S. Kimball Avenue, Southlake, Texas. In addition to the additional seats the District will be repaving a portion of thee existing parking lot which will add approximately 137 parking spaces. We will also be adding approximately 4,350 square feet of additional concession, restrooms and new Disaster Recovery Center to the home side of the stadium. The property is currently zoned S -P-1, Site Plan District. The property is classified as "Industrial - PubliclSemi Public" on the City's Consolidated Land Use Plan. In order to develop the property in a manner that is suitable to the needs of CISD, the property will need to be rezoned Our request is to allow the stadium expansion under S -P-1 Site Plan District Regulations using "CS" Community Service District zoning asour basis. This site shall be subject to all previous conditions of approval unless specifically approved otherwise by the City Council. Regulatory modifications to the CS development regulations include the following: SP I DEVELOPMENT REGULATIONS SITI? PLAN DEVELOPMENT FOR CARROLL I.S.D. STADIUM SITE Permitted Uses: 1. Outdoor sports stadium (includes track and field), offices, meting rooms, concession stands, and sanitary facilities. 2. Bus parking and storage. 3. Bus mechanical maintenance. 4. Private (not for resale) petroleum operations. © fuel storage and dispensing © other petroleum related issues in character with vehicle maintenance and refueling. 12801 N. Centra] Expressway * Suite 1400 * Dallas, TX 75243 *Voice 972-239-51t 1 * Fax 972,239-5053 Page 19 HGAHurt, Gau ler & Associates, Inc. Civil & Structural Engineering A 0 5. Other uses as approved in CS zoning. 6. Tents, portable ticket booths, and portable: toilets shall be permitted in accordance with the attached site plan and all applicable building and fire codes. These structures may not be erected prior to April 1st and must be removed by December 15th of each calendar year. Site plan. Actual construction and usage shall be as shown on site plan as approved. by P&Z and City Council, Development Regulations. 1. Building maximum height limitation - 85 feet. 2. Building setback Front yard 30 feet at S. Kimball Ave., side, and rear yards to be 25 feet. 3. Maximum lot coverage;. Building or structure footprint not to exceed 60%. 4. Maximum impervious coverage not to exceed 95. 5. No additional development regulations provided for residential adjacency. 6. Five foot (5') sidewalks will not be required along the east side of -silicon Drive.. A five-foot (5') sidewalk will be. provided on the west side of Silicon Drive only. 7. Buffer yards -width and type as shown on approved site plan. 8. The: maximum stadium seating shall not exceed. 10,700 seats. 9. Parking: a. Parking for bus maintenance to be as shown on site plan. b. The existing transportation bus lot may be utilized for an additional 140 parking spaces subject to the condition that all buses shall be relocated to an appropriate location suitable for bus storagee the day prior to a game. C. The minimum on-site number of parking spaces provided for stadium seating shall be no less than 2,096 parking spaces for all stadium events. d. The maximum seating to parking space ratio provided on-site shall be no more than 5.105:1. e. No less than 400 off-site parking spaces shall be allocated for employee, band, drill team, and cheerleader parking at the Sr. High School for use: during all stadium events. f. The maximum seating to parking space ratio provided on-site and off-site shall be no more than 4.29.1. 12801 N. Central Expressway * Suite 1400 a Dallas, YX75243 • Voice 972-2395111 • Fax 972-231-5055 Page 20 HGAHart, Gaugler & Associates, Inc. Civil & Structural Engineering 11 0 Landscape: Planting Requirements: All planter islands in parking areas shall contain a minimum of one (1) canopy tree with the remaining area in shrubs, ground cover, grasses or seasonal color. Planter islands which have light poles for lighting the parking areas may substitute two (2) understory/accent trees for the required canopy tree.. All required landscape areas shall be evenly distributed throughout the entire required parking lot landscape areas. Variance requests will include the following: a. Proposed is one accent tree per island with lawn grass underneath and islands will be located on the ends of parking rows as shown on the site plan. b. No landscape area to be provided for seasonal color c. Interior landscaping provided will be 20 sq. ft per parking stall plus landscaping and/or ground cover to be provided at periphery of stadium and other buildings with no calculations based on floor area of buildings.. Please: feel free to contact us with any questions you may have as you review this request. Sincerely, Hart G.augler & Associates, Inc. John D. Blacker, F.E. Principal Pi2ON269136kCiviM ubmhals�2pp}10.2612M7-12-17-LTR-ZANTNs3 NARRATN&99DUTHLA KE. fimLdw 12801 N. Central Expressway 0 Suite 1.360 • 1laIWs TX75243 * Voice 972-239,5111 *Fax 4?' ;y. ; ° Page 21 SITE PLAN APPROVED WITH ORDINANCE NO. 480-330D 1,. 4C T E c LIN E FFE NCREIE �si..� FfFE i I.1 LH LF SG EE EN w a '.: T �.,EE I. E E., LHAIN �'S6'E 1GB6.4E' SB92 d "E 5260 AH �."E EN BARBED c. T .-LL NOS 631°E/ LN fENCE WIRE FENCE FRDM � � � � � ] - - — P E D7seeasFa�aw.t vLaTsaz ss'— { �6 h . _ PLT I1 CLAI FENLE LNR IINSTAL X. LE. SCREENING WALL TO MATCH 16 EN. PLANT PRECAST ARETE ENING I caucRETE FENCING n _ — .1 PAM _ -- IiwlS Eyre nuwu pn cstt ;m11 _ � �— I x sz�T 1 — I caL - wuusr. eL ml n' z+' - I ri CH v IVLET ImYa 19LEr I I I TYP. � — _ F:.4M INLET LE - I III rI :- lD E I I 1 -NG SPADE T. N EX 0' CHAIN Lwk ENDE �' • r Y -,.; q z H i H-1ANT HOME Sas E_IGNL A ILS �1 L —wea•� zo w2A.r1 i RETAININU 11LL29 1 �tIINS$ LIT I HOES PS III — SDEW. LK E _ I SCR D - _ p ' } TgFFM INLET 1 I SPE K R P R F ` JPll�m -I E.a s N v, Ejfll aD - `I '" Ixs T , ^II •_\Idll w L_ - - -eyyI III " E nrvRnN HYDRANT E H. LI. N FENCE _ 5 ®- W v' Lvm` r:Rlu a I.I vrtTTTT� STONM INLET An i4' LVA'' LI} h � f i j'Y r li T • w IIJ• LI. 11 �T ZM IN' ps E%. H MME DUMPSCRE SCREENING ro- 2 fi' HIGH M0.60.NRY SCREENING = H —L nRE�zek.^ J — FR WALL M _ I�Ia I I I I I to C.E GL I PROPOSED CONCRETE `{ AISE P ` PARKING E I `IdP8439 9j II�R ]G 0' EK. B CHEENLE-`I.I - c. 1111 III IeL-zz2f AIN 11NK 5 I I —I 'N" R-1g+�.Ob'I I Pn I. {t Lr 11111TAL I _ SEI x rel- I 6c DFF smE 1 �1 1 L DIN JI SPA4E L ` � � J TRANSPCRTATIOry I � _ � � 6' CDN Al I Ee. TRASH DUMCSTER WTH of 6' HIGH ­RY SCREENING - A WALL I STOPu L �'so•2r Y • R-669§' L E—A B LF N. �: RM LT C-741 1— HEIGHT1"17 r — 11 UE -y 4 �� A, i 2FIoa9'rG II E%. 8 HIGH N TL LDATED / ^"�861,99' "., SCREENING FENCE I - vC } T A N "�'.- X STORM INLET OL-Imm STORM LET, I HZ" D 1's E "•` ] .;�. 5�- C' T1PE A LAN—AHE I �'ITa..OF N'1. N LocAnGN laxsaG rr _ ___ _.. , ' 5 coNCRETc sa oar LS DEWALk Page 22 SITE PLAN DATA APPROVED WITH ORDINANCE NO. 480-330D SITE DATA SUMMARY EXISTING PROPOSED ZONING SP -1 SP -1 LAND USED DESIGNATION PUBLIC/ SEMI-PUBLIC PUBLIC/ SEMI-PUBLIC GROSS ACREAGE 35.801 35.801 NET ACREAGE 35.801 35.801 NUMBER OF PROPOSED LOTS 1 1 AREA OF OPEN SPACE 11.47 ACRES 11.01 AREA OF IMPERVIOUS COVERAGE 24.33 ACRES 24.79 PERCENTAGE OF OPEN SPACE 32.04% 30.75% PERCENTAGE OF IMPERVIOUS COVERAGE 67.96% 69.25% BUILDING AREA (BUILDING FOOTPRINT) STADIUM HOME 44780 44780 STADIUM VISITOR 21540 21540 FIELD HOUSE 11590 11590 MAINTENANCE BUILDING 11535 11535 NUMBER OF STORIES 3 3 MAXIMUM BUILDING HEIGHT 80'-0" 80'-0" PROPOSED FLOOR AREA STADIUM SEATING 10700 10700 HOME 7683 7683 VISITOR 3017 3017 FLOOR AREA BY USE STADIUM BUILDING: CONCESSION 3500 3500 STORAGE 400 400 OFFICE 1500 1500 RESTROOMS 4875 4875 PRESS BOX 3,379 3379 D.R.0 1700 FLOOR AREA BY USE MAINTENANCE BUILDING: SHOP 5825 5825 OFFICE 1750 1750 STORAGE 2057 2057 REQUIRED PARKING/GAME 2096 2096 PROVIDED PARKING/GAME STANDARD 2054 2052 HANDICAP 42 44 TOTAL 2096 2096 BUSES 26 44 PROVIDED PARKING/NON-GAME STANDARD 1914 1911 HANDICAP 42 44 TOTAL 1956 1955 BUSES 94 94 LOADING SPACES: REQUIRED/PROVIDED TWO/TWO TWO/TWO AREA OF OUTSIDE STORAGE 108150 108150 PERCENTAGE OF OUTSIDE STORAGE 7.00% 7.00% START CONSTRUCTION MONTH/YEAR JULY 2018 END CONSTRUCTION MONTH/YEAR AUGUST 2018 Page 23 S -P-1 REGULATIONS APPROVED WITH ORDINANCE NO. 480-330D f3HART GAUGLER + ASSOCIATES April 24, 2018 Richard Schell City of Southlake, Texas Planning and Development Services 1400 Main Street, Suite 310 Southlake, Texas 76092 Re: Carroll Independent School District Dragon Stadium Addition —Zoning Narrative— ZA 18-032 Dear Richard: Carroll ISD desires to add pavement for 18 additional bus parking spots at 1085 S. Kimball Avenue, Southlake, Texas. In addition to the additional pavement, the District will be providing a speed table and restriping some parking for handicap spaces. A storage structure will be added to store tires out of the elements. The structure will be approximately 1,200 square feet. The property is currently zoned S -P-1, Site Plan District. The property is classified as "Industrial - Public/Semi Public" on the City's Consolidated Land Use Plan. In order to develop the property In a manner that is suitable to the needs of CISD, the property will need to be rezoned. Our request is to allow the stadium expansion under S -P-1 Site Plan District Regulations using "CS" Community Service District zoning as our basis. This site shall be subject to all previous conditions of approval unless specifically approved otherwise by the City Council. Regulatory modifications to the CS development regulations include the following: SP 1 DEVELOPMENT REGULATIONS SITE PLAN DEVELOPMENT FOR CARROLL I.S.D. STADIUM SITE Permitted Uses: 1. Outdoor sports stadium (includes track and field), offices, meeting rooms, concession stands, and sanitary facilities. 2. Bus parking and storage. 3. Bus mechanical maintenance. 4. Private (not for resale) petroleum operations: o fuel storage and dispensing • other petroleum related issues in character with vehicle maintenance and refueling. 5. Other uses as approved In CS zoning. 6. Tents, portable ticket booths, and portable toilets shall be permitted in accordance with the attached site plan and all applicable building and fire codes. These structures may not be erected prior to April 1st and must be removed by December 15th of each calendar year. 12801 N. Central Expressway. Suite 14170, Dallas, TX 75243 hartgaugler.com Page 24 1:3 HART GAUGLER + ASSOCIATES Site plan: Actual construction and usage shall be as shown on site plan as approved by P&Z and City Council. Development Regulations: 1. Building maximum height limitation - 85 feet. 2. Building setback -Front yard 30 feet at S. Kimball Ave., side, and rear yards to be 25 feet. 3. Maximum lot coverage: Building or structure footprint not to exceed 60%. 4. Maximum impervious coverage not to exceed 95%. 5. No additional development regulations provided for residential adjacency. 6. Five foot (5') sidewalks will not be required along the east side of Silicon Drive. A five-foot (5') sidewalk will be provided on the west side of Silicon Drive only. 7. Buffer yards -width and type as shown on approved site plan. 8. The maximum stadium seating shall not exceed 10,700 seats. 9. Parking: a. Parking for bus maintenance to be as shown on site plan. b. The existing transportation bus lot may be utilized for an additional 140 parking spaces subject to the condition that all buses shall be relocated to an appropriate location suitable for bus storage the day prior to a game. C. The minimum on-site number of parking spaces provided for stadium seating shall be no less than 2,096 parking spaces for all stadium events. d. The maximum seating to parking space ratio provided on-site shall be no more than 5.105:1. e. No less than 400 off-site parking spaces shall be allocated for employee, band, drill team, and cheerleader parking at the Sr. High School for use during all stadium events. f. The maximum seating to parking space ratio provided on-site and off-site shall be no more than 4.29:1. Landscape: Planting Requirements: All planter islands in parking areas shall contain a minimum of one (1) canopy tree with the remaining area in shrubs, ground cover, grasses or seasonal color. Planter islands which have light poles for lighting the parking areas may substitute two (2) understoryfaccent trees for the required canopy tree. All required landscape areas shall be evenly distributed throughout the entire required parking lot landscape areas. Previous variance requests included the following: a. Proposed is one accent tree per island with lawn grass underneath and islands will be located on the ends of parking rows as shown on the site plan. Page 25 1:3 HART GAUGLER + ASSOCIATES b. No landscape area to be provided for seasonal color c. Interior landscaping provided will be 20 sq. ft per parking stall plus landscaping and/or ground coverto be provided at periphery of stadium and other buildings with no calculations based on floor area of buildings. New variance requests for this submittal will include the following: A. A variance to the Landscape Ordinance 544-B to request relief from the interior landscaping requirement. B. An S -P-1 regulation to request relief from the bufferyard requirements. C. A regulation to allow the articulation on the alternate tire storage building to be as shown. No other changes to the previously approved S -P-1 zoning district are proposed and all other previous conditions of approval remain in effect. Please feel free to contact us with any questions you may have as you review this request. Sincerely, Hart, Gaugler + Associates, Inc. John D. Blacker, P.E. Principal F:E2017N217307�CivillSuhmlttalsNCity SubmittalsN2018-04-24 update for councir�317307-Zoning Design Narrative.doc 12801 N. Central Expressway, Suite 1400, Dallas, TX 75243 hartgaugler.corr Page 26 ELEVATIONS APPROVED WITH ORDINANCE NO. 480-330D 051 EXTERIOR ELEVATION -WEST •AER#NCF 6Z'W1 FOA MAIEA�U OE314WwOF5 cunae,a�wowwsaErva� new ON W I FERiN! f EMwEn SYSiA1 .�ErEF;NCF a�,u, von nut¢m¢ oEracrenrp EXTERIOR ELEVATION - NORTH W .O WF W.aL 8E"D T PARAPET_ 117-P GRADE 1C�'-D. T. PA APET 11T-7• Y ti GRA00'DE 1 T. PARAPET 031 EXTERIOR ELEVATION - EAST �rwA� T. P 1AR,�APET Page 27 3rwomc suMueAuavv cu+rEo rEru curiFw ccFnaamFr con,sa cx _ m, x�owri=_w.nc� Pw Dw,oam+ air � HAAT GIASiFA SSW.C3 fWl;x lrrB g i Mw.1W[NNf55i OYEP➢VAgN6AETN i i aAmt-t y� ^ I aissc-z I ;m I I I I CMV -1 n � 2 :1 J 1 cW3 G _ GRADE 100, Lr' 021 EXTERIOR ELEVATION - SOUTH (FACES KIMBALL AVENUE) Page 27 FLOOR PLAN APPROVED WITH ORDINANCE NO. 480-330D 0.01 011FLOOR PLAN - STORAGE BUILDING m Page 28 MATERIALS APPROVED WITH ORDINANCE NO. 480-330D EXTERIOR MATERIAL LEGEND NOTE: ALL PROPOSED MATERIALS TO MATCH EXISTING BUILDING ALL METAL COPING, STANDING SEAM METAL ROOF, GARAGE DOORS, AND LOUVERS TO MATCH EXISTING HUNTER GREEN FINISH 3 -COAT PLASTER STUCCO FINISH (7J8" MIN. THICKNESS) OVER DIAMOND METAL LATH MESH BRICK -2, MODULAR CMU -1, SPLIT FACE BRICK -1, MODULAR CMU -3, SPLIT FACE CMU -2. SPLIT FACE Page 29 TREE CONSERVATION PLAN APPROVED WITH ORDINANCE NO. 480-330D I { ro-N , — J. .77 - � { 1 I I I w I I T Lir •- �� -. .�.-:� -._ � - /�,y'� �,�P� �F,-� TREE PRESERVATION SUMMARY NET ACREAGE 41.347 ac. EXISTING TREE COVERAGE (0-20%) 9.6% PERCENTAGE TREE COVERAGE PRESERVED (70% MIN.) 93 TOTAL TREES 74 PROTECTED TREES 54 TREES REMOVED 20 INCHES TO BE MITIGATED 386 Page 30 EXHIBITS APPROVED WITH ORDINANCE NO. 480-330E Addendum #1 To S -P-1 Development Regulations Case # ZA03-005 (Ordinance No. 480-330A) The purpose of this addendum is to provide additional information on the various elements that are being proposed by Carroll Independent School District (CISD) and the Dallas Burn Soccer Team at Carroll Dragon Stadium. This addendum is intended to accompany and provide further explanation of the revised site plan. 9. Parking. The accompanying site plan delineates the revised parking plan for the CISD Dragon Stadium utilizing property wholly owned and controlled by CISD. The site plan indicates approximately 3.14 acres to the northwest of the current paved parking lot. It is intended to level, grade, and gravel this portion of CISD property in order to park an additional 497 cars. This will be accomplished with the aide of professional parking company that will direct cars by way of personnel instead of striping paint. The lot will be graded and covered with a 6" flex base of gravel along with the required material to minimize dust. All required plans will be submitted in order to satisfactorily complete this project. Additionally, the existing transportation bus lot will be maximized in a similar fashion to the proposed gravel lot. This will be accomplished by removing the existing concrete bus wheel stops on the day of the event and then using managed parking just as with the proposed gravel lot. In this same fashion, it is expected that approximately 469 cars can be parked on this lot. The revised site plan includes a parking legend. This legend in addition to showing the total space count for the stadium, it also shows the improved parking ratio. Furthermore, the parking ratio is improved even more when the off-site parking is taken into consideration for employee parking. Page 31 10. Bleachers. It is proposed that 1,620 bleacher seats will be added to the eastern end of Dragon Stadium on the existing concrete pad. The bleachers will be constructed and erected in two separate sections of 810 seats each. Each bleacher section will be approximately ninety-nine (99) feet by twenty-nine (29) feet and one (1) inch. Each section will have fifteen (15) rows with seating based upon eighteen (18) inch centers. All necessary permits will be obtained. See attached letter from bleacher manufacturer. 11. "Permanent Tents". The phrase "permanent" is used because it is intended that these tents will be in place longer than the stipulated 180 days to be classified as a "temporary" tent. It is proposed to erect two (2) frame tents inside the stadium for the purposes of fan and sponsor entertainment. Tent #1: a. Location: parking lot immediately to the west of the field and behind the existing stadium scoreboard. b. Size: 30 feet by 100 feet (3,000 square feet) c. Type: White frame tent with perimeter pole supports -no internal pole supports d. Construction: e. Attachment: Affixed directly to the concrete f. Duration: April 2003 through December 2003 g. Engineering Specifications: Designed to withstand seventy (70) mile per hour winds. h. Additional Information: -Added wind screen meshing along western edge of tent to block western setting sun -Add 10 light bars with 4 Par 38 fixtures, gel frame, assorted gels, 150 watt flood lamps along with the necessary wire, dimmers, and quad boxes. -Add necessary wiring, cable hook-ups, televisions/platforms to provide television reception to tent from television truck. -Utilize sufficient box fans to circulate air for comfort -Proposed hours of operation: two (2) hours prior to the start of the game and one (1) hour after the game. -Food and beverages will be served by the official stadium concessionaire or an approved third party concessionaire. This concessionaire will comply with all local, county, state regulations in regard to all health department and fire safety issues. -Any and all permits that may be required by local, county, or state agencies will be obtained. Tent #2: a. Location: grass/concrete pad immediately to the east of the current visitor's bleachers on the south side of the stadium. b. Size: 30 feet by 40 feet (1,200 square feet) c. Type: White frame tent with perimeter pole supports -no internal pole supports d. Construction: e. Attachment: Affixed directly to the concrete. f. Duration: April 2003 through December 2003 g. Engineering Specifications: Designed to withstand seventy (70) mile per hour winds. h. Additional Information: -Add 6 light bars with 4 Par 38 fixtures, gel frame, assorted gels, 150 watt flood lamps along with the necessary wire, dimmers, and quad boxes. Page 32 -Utilize sufficient box fans to circulate air for comfort -Proposed hours of operation: two (2) hours prior to the start of the game and one (1) hour after the game. -Food and beverages will be served by the official stadium concessionaire or an approved third party concessionaire. This concessionaire will comply with all local, county, state regulations in regard to all health department and fire safety issues. -Any and all permits that may be required by local, county, or state agencies will be obtained. 12. Temporary Tents. (By definition -less than 180 days). As part of the game day operation, it is intended to utilize a variety of "pop-up" tents through out the stadium and it surroundings. These tents are ten (10) feet by ten (10) feet (100 square feet) when erected, aluminum construction with a vinyl top. These types of tents will only be erected on the day of the event and will be taken down the same day. Some of the intended uses are: a) First Aide/Paramedic Stations b) Promotional for sales or sponsorship c) Merchandise 13. Ticket Booths. It is intended to locate two (2) auxiliary ticket booths at the stadium in order to provide supplemental locations to sell tickets on the day of the event. Each of these ticket booths is made of corrugated metal siding and roofing, one door, and built on wooden skids. They are nine (9) feet wide by twenty (20) feet long accommodating spaces for five (5) ticket windows. The windows are made of a protective glass with a small opening to accommodate a ticket transaction. The ticket booths have a simple lighting fixture and a small window air conditioning unit. -Location: one (1) would be located immediately to the east of the permanent ticket windows on the north side of the stadium on the grass pad. The second would be located on the south side of the stadium immediately to the left or west of the drive gate on the grass pad. -Both will be positioned in such a manner as to maintain the requisite three (3) foot radius around each existing fire plug. -All required permits will be obtained for the ticket booths and for the electrical work necessary to provide power to each booth. 14.Inflatables (Air -Inflated Structure). As part of the overall entertainment package, it is intended to utilize interactive inflatables such as bounce houses for children. These inflatables typically do not exceed the dimensions of ten (10) feet by thirty (30) feet. They are erected only on the day of event for two hours prior to the start of the game. -Location: Northeast side of stadium outside of the stadium fence Southeast side of stadium outside of the stadium fence -Power: Air blower powered by an approved generator -Time: Event day only for two (2) hours prior to game time -Staff: Erected and staffed by Dallas Burn trained personnel 15. Portable toilets. It is intended to place portable toilets in two locations of the stadium. The purpose is to provide access to toilet for patrons that might not otherwise have access and to provide auxiliary toilets to ease the potential burden on existing restroom facilities. All portable toilets will be inside the existing stadium fencing and not visible from the street. Page 33 -Location #1: East end of stadium adjacent to the current field house and behind the proposed bleachers. Research does not indicate a specific rule as per the number of units required. However, there appears to be a universal standard of approximately one (1) unit per 125 people. Applying this standard to the proposed number of bleacher seats (1,620), it is recommended to add approximately 10-12 units including a handicapped unit. -This is being done since the proposed bleachers for general admission seating only and thus these fans will not have access to other areas of the stadium. -Location #2: Southwest section of the stadium immediately to the west of the visitor's stands. Though fans in this area will have access to the permanent restrooms, it is intended to augment the existing facilities in order to relief potential congestion. It is intended to add six (6) units in this area. It is intended to leave the portable toilets in place through the entire season. The proposed contract with the portable toilet company will call for weekly cleaning of the units. 16. Lighting. It is our understanding from discussions with city staff that the property is in compliance with the current lighting ordinance for this specific type of land use based upon the variance granted. 17. Noise. It is our understanding from discussions with city staff that the property is in compliance with the current noise ordinance for this specific type of land use and the number of events based upon the variance granted. 18. Landscaping. It is our understanding that all landscaping requirements have been met. 19. Building Occupancy. It is our understanding with discussions with city staff that total occupancy of the facility will be based upon a calculation of what is safe for this type of facility and its type of use. This calculation is not tied just to the physical seats. Page 34 Addendum #2 To S -P-1 Development Regulations Case # ZA03-057 (Ordinance No. 480-3306) Carroll ISD Zoning Application Change/Site Plan Revision Removal of screening device and landscape buffer on West side of parking lot In the previous site plan submitted to the City of Southlake, a type `A' buffer yard and 390 L.F. 8' high screening device were included and approved by the City. Subsequent to the approval of that site plan, CISD constructed the parking lot referenced in the site plan. At the completion of the parking lot, CISD noted that there was a significant fall off from the side of the parking lot to the property owned by Mr. Louis Kaposta. CISD spoke with Mr. Kaposta and we agreed that the removal of the existing trees to construct an 8' fence would provide less screening than currently exists. According, with the support of the adjacent property owner (Mr. Kaposta), CISD is requesting the elimination of the requirements for a bufferyard and a screening device on the west side of the property adjacent to Mr. Kaposta's property. Page 35 Addendum #3 To S -P-1 Development Regulations Case # ZA09-057 (Ordinance No. 480-330C) The purpose of this addendum is to add 1,600 seats to the home side of Dragon Stadium. In addition to the additional seats the District will be repaving the northwest portion of the existing parking lot which will add approximately 137 parking spaces. This addendum also includes approximately 4,350 square feet of floor space consisting of additional concessions, restrooms and new Disaster Recovery Center to the home side of the stadium. Page 36 Addendum #4 To S -P-1 Development Regulations Case # ZA18-032 (Ordinance No. 480-330D) The purpose of this addendum is to provide additional information on the various elements that are being proposed by Carroll Independent School District (CISD) at the Carroll Dragon Stadium property. This addendum is intended to accompany and provide further explanation of the revised site plan. The purpose of this request is to seek approval of a Zoning Change and Site Plan to allow pavement for 18 additional bus parking spaces and the addition of an approximately 1,200 square foot storage building for tire storage at Dragon Stadium. No other changes to the previously approved "S -P-1" zoning regulations are proposed and all previous conditions of approval remain in effect. Addendum #5 To S -P-1 Development Regulations Case # ZA19-0067 (Ordinance No. 480-330E) Page 37 EXHIBIT "C" REGULAR PLANNING & ZONING COMMISSION MEETING 667 NORTH CARROLL AVENUE SOUTHLAKE, TEXAS FEBRUARY 3, 2000 MINUTES Ordinance No. 480-330 Motion was made to approve ZA 99-132 subject to Site Plan Review Summary No. 2, dated January 28, 2000; and subject to the following: • acknowledging some of the reasons for not going with straight "CS" zoning are the residential properties to the north; the industrial properties surrounding it; the particular needs and concerns surrounding this type of a use, a stadium; and in addition, they have several uses that did not come in under straight "CS" zoning such as the transportation facility; • striking the following use within the "CS" zoning district: 8.2.g: Utility buildings and structures: power sub -stations, water tanks and reservoirs, water and sewage treatment plants; • deleting Item #1.13.1 (height); • deleting Item #1.B.2 (maximum lot coverage); • amending Item #1.13.3 allowing a limit of 85% impervious coverage; • requiring compliance with Item #1.C.1 (residential adjacency); • deleting Item #1.D.1 and acknowledging the applicant's willingness and effort to work with the Landscape Administrator to landscape the best they can with native vegetation that provides some color and requires little or no watering; • granting a variance on Item #1.D.2 allowing the applicant to move some of the interior plantings to the outside bufferyards with the understanding that by the time they get to City Council they will work out the numbers to see if they are able to have some relief of some of these trees and trees in other district properties in exchange for a brick wall that would border the northern properties; • deleting Item #1.E.1 and accepting 1 space per 5 seats; • noting the district's willingness to comply with Item #5.13 with their study which shows they come under the limit of the decibels at the property line; • adding Item #5.D requiring compliance with driveway stacking requirements but granting a variance to it and recognizing that the district is going to provide gates on both ends of the area between the field house and Silicon Drive such that the stacking depth would actually be 163'; City Attorney Debra Drayovitch said there are requirements for obtaining a variance to the Lighting Ordinance which require submission of an alternate plan and certain evidence, and she is certain the Commission would want to have that reviewed by the appropriate staff. Continuation of motion: • Requiring compliance with the Lighting Ordinance but recognizing the applicant has the lighting study and will submit it before they go to City Council and allow staff time to review it; and • Requiring the gates to the east of the field house to remain closed during the games and for a period of 30 minutes after the games except for emergency access. Page 38 Motion: Shankland Second: King Ms. Drayovitch said there has been discussion of "variances" associated with this plan but with an "S -P" zoning these items are not variances; they are part of this planned development Site Plan zoning. She wanted the record to reflect they are really not variances and that the Commission does have more discretion with this type of application. Ayes: Boutte, Shankland, King, Creighton Nays: Peebles Approved: 4-1 Motion carried. (Planning and Zoning Commission meeting, 02-03-00, tape 1, section #4207) REGULAR CITY COUNCIL MEETING 667 NORTH CARROLL AVENUE SOUTHLAKE, TEXAS FEBRUARY 15, 2000 MINUTES Ordinance No. 480-330 Motion was made to approve Ordinance No. 480-330,1s1 Reading, (ZA 99-132), subject to the Revised Site Plan Review Summary No. 2, dated February 11, 2000, incorporating Planning and Zoning Commission's recommendations with the following changes and additions: • Recognizing the district's commitment to the north property owner for putting panels in the chain-link fence; • Recognizing the district's commitment to the western property owner with the chain-link fence adding slats; northern property owners with a tilt -wall brick -look fence behind those owners, allowing the district to eliminate two rows of landscaping medians in the parking lot which will enable them to increase the bufferyard on the north from approximately 30' to 50' recognizing they will bring in those exact numbers at the second reading; • Accepting the lighting for the facility, on the field as demonstrated tonight using the internal shields with the visors; • Allowing the district to phase in the tree mitigation plan which they accept over the next five (5) years, so that they can use operating funds instead of bond funds; • Limiting events by entities other than the CISD and City of Southlake to ending at 11:00 p.m.; • Accepting the district's commitment to not light any signs on the north side of the property; • Accepting the district's commitment to the best of their ability to bring forward at the second reading, a reciprocal parking agreement with adjacent property owners; • Allowing white lights; • Allowing the variance as requested from the school district on the lights on the field; and, • Deferring the 8' screening. Motion: Edmondson Second: Fawks Page 39 Councilmember Rex Potter stated, "I will vote for this, but if I do not get more confidence on the lights at the next reading, we have gone the maximum to mitigating the impact. They need to do a little bit better as to their diminishing returns for it is to their significant benefit to put the shields on the lights. I will expect the school district to come back with a lighting specialist to give more information." Ayes: Edmondson, Fawks, Potter, Kendall, DuPre, and Stacy Nays: None Approved: 6-0 vote REGULAR CITY COUNCIL MEETING 667 NORTH CARROLL AVENUE SOUTHLAKE, TEXAS 76092 MARCH 7, 2000 MINUTES Ordinance No. 480-330 Motion was made to approve ZA 99-132, subject to the Site Plan Review Summary No. 2, dated February 11, 2000; incorporating all of the requirements of the motion made during first reading; and further requiring that no activities requiring stadium lights or auditory speakers will be allowed between 11:00 p.m. and 8:00 a.m.; and that no games be allowed to start after 10:00 p.m.; Subject to the revised Site Plan that was presented this evening; and clarifying slats be added on all of Mr. Kaposta's fence. Motion: Fawks Second: Edmondson Ayes: Fawks, Edmondson, Potter, Kendall, Moffat, DuPre, and Stacy Nays: None Approved: 7-0 vote City of Southlake SPECIAL CITY COUNCIL MEETING March 7, 2003 Ordinance No. 480-330A Motion was made to approve Ordinance No. 480-330a, 1St Reading, subject to Revised Site Plan Review Summary No. 2, dated February 28, 2003; accepting changes as proposed by the applicant tonight; requiring the applicant to oil the gravel parking lot to keep the dust down; allowing the proposed portable toilets and tents for one year and requiring approval by SUP after that time period; deleting the request for extended hours; accepting the proposed parking as presented tonight and if it requires a variance, granting a variance; accepting the applicant's commitment for temporary directional signs along the roadways; and accepting the applicant's offer to put an item on their next bond election to permanently pave the parking lot. Motion: Potter Second: Standerfer Ayes: Evans, Shankland, Morris, Standerfer, Potter, Stacy Page 40 Nays: None Approved: 6-0 Page 41 City of Southlake CITY COUNCIL MEETING March 18, 2003 Ordinance No. 480-330A Motion was made to approve Ordinance No. 480-330a, 2nd Reading, subject to Site Plan Review Summary No. 3, dated March 14, 2003, incorporating the motion from the first reading approval; subject to the photometric survey dated February 9, 2000, referenced by staff tonight; extending the 8' masonry wall to the west, in line with the east property boundary of Mr. Kaposta's property and extending the 8' masonry wall south along Mr. Kaposta's property line and removing the 8' masonry wall from the northwest portion of the site plan along Mrs. Sapp's property; requiring CISD to use effective dust control on the gravel parking lot; requiring CISD to restrict access to the gravel parking lot when not in use; requiring that parking is no closer than 20' from Mr. Kaposta's property; restricting off-site parking to Old Union Elementary School for the employees and adjusting the parking ratio in the regulations accordingly; requiring a 50' bufferyard adjacent to the gravel parking area along the north property line and allowing the landscape plantings to be deferred until permanent paving is installed; and incorporating the documents referenced in the site plan review summary. Motion: Potter Second: Evans Ayes: Evans, Shankland, Morris, Standerfer, Potter, Stacy Nays: None 6-0 City of Southlake CITY COUNCIL MEETING MINUTES September 2, 2003 Ordinance No. 480-3306 Motion was made to approve Ordinance No. 480-330b (ZA03-057) 2nd Reading, requiring the existing vegetation in the bufferyard be permanently maintained so long as the use is maintained. Motion: Standerfer Second: Shankland Ayes: Potter, Evans, Shankland, Morris, Standerfer, Wambsganss Nays: None Approved: 6-0 (Stephen out of the room) Page 42 City of Southlake CITY COUNCIL MEETING MINUTES December 15, 2009 Ordinance No. 480-330C Motion was made to approve Ordinance No. 480-330c, 1st Reading (ZA09-057), Zoning Change and Site Plan for Dragon Stadium Expansion granting the requested variances but requiring the sidewalk on the west side of Silicon Drive from the existing sidewalk back to Kimball Avenue to be constructed; subject to the applicant's presentation; and subject to Site Plan Review Summary No. 4, dated December 8, 2009. Motion: Jones Second: Morris Ayes: Bledsoe, Jones, Morris, Muller, Muzyka, Terrell Nays: None Approved: 6-0 City of Southlake CITY COUNCIL MEETING MINUTES January 5, 2010 Ordinance No. 480-330C Motion was made to approve Ordinance No. 480-330c, 2nd Reading (ZA09-057), Zoning Change and Site Plan for Dragon Stadium Expansion granting the requested variances but requiring a five-foot sidewalk on the west side of Silicon Drive only; requiring the additional screening fence; and subject to Site Plan Review Summary No. 4, dated December 8, 2009. Motion: Jones Second: Morris Ayes: Bledsoe, Jones, Morris, Muller, Muzyka, Terrell Nays: None Approved: 6-0 Page 43 City of Southlake CITY COUNCIL MEETING MINUTES May 15, 2018 Ordinance No. 480-330D Motion was made to approve Item 6B, Ordinance No. 480-330D (ZA18-032), Zoning Change and Site Plan for Carroll ISD No. 6 Addition (Dragon Stadium), subject to the Staff Report dated May 8, 2018, and the Site Plan Review Summary No. 3, dated April 23, 2018, and granting the following variance: - Landscape Ordinance 544-B, a variance to the Landscape Ordinance to request relief from the interior landscaping requirements to allow interior landscaping to remain as it currently exists on the site. - Also noting that unless noted in the staff report or indicated on the site plan and elevations or as part of the motion, all previous zoning regulations for the Dragon Stadium site will remain. Motion: Williamson Second: McCaskill Ayes: Shafi, McCaskill, Patton, Hill, Williamson, Huffman, Archer Approved: 7-0 Site Plan Review Summary No. 3, dated April 23, 2018: I:A_\,1►1V[rZdelIT, ILy, 14►11116"1 The property is in the Non -Residential Development Overlay District, Section 43 of Zoning Ordinance No. 480, as amended, so all plans must comply with the requirements in that section. The horizontal and vertical articulation on the proposed 40' x 30' tire storage building meet the articulation requirements in Section 43. Horizontal and vertical articulation will be required on the 50'x 18' alternate tire storage building if the wall heights are less than 1/3 of the 50' fagade lengths. The applicant has added an "S -P-1" regulation to allow the articulation as shown for the alternate tire storage building. Tree Conservation/Landscape Review TREE CONSERVATION COMMENTS: There is approximately 9.6% of existing tree cover on the site and the applicant is proposing to preserve approximately 93% of the existing tree cover. Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please Page 44 ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. LANDSCAPE COMMENTS: 1. The proposed building does not exceed 5,000 square feet or 30% of the existing buildings floor area, so 30% of the proposed building floor area (1,200 square feet x 30% = 360 square feet) is required to be calculated for the required interior landscape area and plant material. The applicant is requesting a variance to the Landscape Ordinance to request relief from the interior landscaping requirements (Variance approved). 2. Any requests for changes in zoning to any district other than agricultural or single family residential districts shall require that all bufferyards be installed prior to issuance of a CO. An S -P-1 regulation has been added to request relief from the bufferyard requirements. Indicates informational comment. # Indicates required items comment. City of Southlake CITY COUNCIL MEETING MINUTES January 7, 2020 Ordinance No. 480-330E Page 45