Item 7 - PlansCOVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS D A. HOFFMAN 10/1/2019 AERIAL RENDER, PATHWAY A AC AFCI AZIM COMP DC (E) EXT FRM INT LBW MAG MSP (N) NTS OC PRE-FAB PSF PV TL TYP V W AMPERE ALTERNATING CURRENT ARC FAULT CIRCUIT INTERRUPTER AZIMUTH COMPOSITION DIRECT CURRENT EXISTING EXTERIOR FRAMING INTERIOR LOAD BEARING WALL MAGNETIC MAIN SERVICE PANEL NEW NOT TO SCALE ON CENTER PRE-FABRICATED POUNDS PER SQUARE FOOT PHOTOVOLTAIC TRANSFORMERLESS TYPICAL VOLTS WATTS PAGE REV: D 10/1/2019 2940 N. STATE HIGHWAY 360, SUITE 200, GRAND PRAIRIE, TX 75050 PHONE 832-572-0091 FAX 0 TRUSHIL SHAH 1507 SPRUCE CT, SOUTHLAKE, TX, 76092 PROJECT NUMBER: 351R-507SHAH SHEET DESIGNER: DAVE CARDELLO CUSTOMER RESIDENCE: TEL. (425) 922-8664 APN #: 6940587 ---- (415) 580-6920 ex3 TABLE OF CONTENTS PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-1.0 VICINITY MAP ·SYSTEM SIZE: 7260W DC, 6000W AC ·MODULES: (22) LG ELECTRONICS: LG330N1C-A5 ·INVERTER(S): (1) SOLAREDGE TECHNOLOGIES: SE6000H-US WITH REVENUE GRADE METERING ·RACKING: SNAPNRACK RL; FLASHTRACK COMP, SEE DETAIL SD-00708 LEGEND AND ABBREVIATIONS SCALE: NTS MAIN PANEL INVERTER(S) WITH INTEGRATED DC DISCONNECT AND AFCI AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL MP SP LC SM PM INV AC DC CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER UM COMBINER BOX HARDSCAPE PROPERTY LINEINTERIOR EQUIPMENT SHOWN AS DASHED PL SOLAR MODULES SNR A MOUNT SNR B MOUNT ONCOR UTILITY METER • ALL WORK SHALL COMPLY WITH NEC 2017, IBC 2015, IFC 2018, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 10.45 AMPS MODULE SHORT CIRCUIT CURRENT. • 16.32 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION PL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPLPLPL PL PL PL PL PAGE REV: D 10/1/2019 2940 N. STATE HIGHWAY 360, SUITE 200, GRAND PRAIRIE, TX 75050 PHONE 832-572-0091 FAX 0 TRUSHIL SHAH 1507 SPRUCE CT, SOUTHLAKE, TX, 76092 PROJECT NUMBER: 351R-507SHAH SHEET DESIGNER: DAVE CARDELLO CUSTOMER RESIDENCE: TEL. (425) 922-8664 APN #: 6940587 ---- (415) 580-6920 ex3 SITE PLAN PV-2.0 SITE PLAN - SCALE = 1/16" = 1'-0" (E) DRIVEWAY (E) RESIDENCE UM MP INVAC AC FIRE SETBACKS (3' TYP) (N) ARRAY AR-02 (N) ARRAY AR-01 6'-10" 3'-5" 3'-8" 3' 3'-5" 3'-10" 36'-8" 29'-5" 57'-5" 22'-1" SP R U C E C T SPRUCE CT NEIGHBORING PROPERTY (EAST) NEIGHBORING PROPERTY (NORTH) D ROOF PATHWAYS (3' TYP) ARRAY PITCH PV AREA (SQFT) AR-01 40°295 AR-02 40°110.6177° TRUE AZIM MAG AZIM 174°177° 174° ARRAY PITCH 10/12 10/12 PAGE REV: D 10/1/2019 2940 N. STATE HIGHWAY 360, SUITE 200, GRAND PRAIRIE, TX 75050 PHONE 832-572-0091 FAX 0 TRUSHIL SHAH 1507 SPRUCE CT, SOUTHLAKE, TX, 76092 PROJECT NUMBER: 351R-507SHAH SHEET DESIGNER: DAVE CARDELLO CUSTOMER RESIDENCE: TEL. (425) 922-8664 APN #: 6940587 ---- (415) 580-6920 ex3 MODULES: LG ELECTRONICS: LG330N1C-A5 MODULE DIMS: 66.38" x 40" x 1.57" (40mm) MODULE CLAMPS: Portrait: 7.9" - 15.7" Landscape: 0" - 4.7" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 5 PSF WIND SPEED: 115 MPH 3-SEC GUST. LAG SCREWS: 5/16"x4": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. PENETRATION SPACING: FULLY STAGGERED ROW SPACING: 0.5" BETWEEN ROWS COLUMN SPACING: 0.5" BETWEEN COLUMNS DESIGN CRITERIA SEE SITE PLAN FOR NORTH ARROW PV-3.0 LAYOUT D1 - AR-01 - SCALE: 1/8" = 1'-0" PITCH: 40° AZIM: 177° D2 - AR-02 - SCALE: 1/8" = 1'-0" PITCH: 40° AZIM:177° ROOF TYPE MOUNTING DETAIL ROOF HEIGHT ROOF EXPOSURE FRAME MATERIAL FRAME TYPE FRAME SIZE MAX FRAME SPAN OC SPACING ROOF EDGE ZONE MAX PEN SPACING MAX MOD. OVERHANG AR-01 COMP SHINGLE - RL FLASHTRACK COMP, SEE DETAIL SD-00708 1 STORY ATTIC WOOD 2X6 RAFTERS 2 X 6 10' - 2"24"3' - 2"4' - 0"1' - 4" AR-02 COMP SHINGLE - RL FLASHTRACK COMP, SEE DETAIL SD-00708 1 STORY ATTIC WOOD 2X6 RAFTERS 2 X 6 11' - 10"24"3' - 2"4' - 0"1' - 4" 3'-5" 20'-5" 8'-3" 6'-10" 4' TYP 1' 10'-2" 3'-10" 7'-9"11'-2" 4' TYP SOLAR MODULE SNAPNRACK RACKING 6" MODULE ELEVATION DETAIL - SCALE: NTS 3 FACILITY GROUND FACILITY LOADS EXISTING 200A MAIN BREAKER EXISTING 200A MAIN PANEL SUPPLY SIDE TAP SQD QO24L70FCP, 70AMP, 120/240, 1PH 2SP, 4CR, NEMA-1 (N) 70A PV LOAD CENTER *NO LOADS TO BE INSTALLED* 40A BREAKER 4 M METER #: ONCOR 143873990 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID JUNCTION BOX OR EQUIVALENT 12 SOLAREDGE TECHNOLOGIES: SE6000H-US WITH REVENUE GRADE METERING 6000 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN COMPLIANT PV MODULES LG ELECTRONICS: LG330N1C-A5 (22) MODULES OPTIMIZERS WIRED IN: (1) SERIES OF (8) OPTIMIZERS (1) SERIES OF (14) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS P370 3 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV.(2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 PAGE REV: D 10/1/2019 2940 N. STATE HIGHWAY 360, SUITE 200, GRAND PRAIRIE, TX 75050 PHONE 832-572-0091 FAX 0 TRUSHIL SHAH 1507 SPRUCE CT, SOUTHLAKE, TX, 76092 PROJECT NUMBER: 351R-507SHAH SHEET DESIGNER: DAVE CARDELLO CUSTOMER RESIDENCE: TEL. (425) 922-8664 APN #: 6940587 ---- (415) 580-6920 ex3 PV-4.0 ELECTRICAL SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: 7260 W 14 V 380 V 480 V 19.11 A 30 A P370 OPTIMIZER CHARACTERISTICS: MIN INPUT VOLTAGE: 8 VDC MAX INPUT VOLTAGE: 60 VDC MAX INPUT ISC: 11 ADC MAX OUTPUT CURRENT: 15 ADC MODULE CHARACTERISTICS LG ELECTRONICS: LG330N1C-A5: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 330 W 40.9 V 33.7 V 10.45 A VISIBLE LOCKABLE LABELLED DISCONENCT VISIBLE LOCKABLE LABELLED DISCONENCT (EXTERIOR HANDLE) NOTES TO INSTALLER: ·14 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. ·CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. PAGE REV: D 10/1/2019 2940 N. STATE HIGHWAY 360, SUITE 200, GRAND PRAIRIE, TX 75050 PHONE 832-572-0091 FAX 0 TRUSHIL SHAH 1507 SPRUCE CT, SOUTHLAKE, TX, 76092 PROJECT NUMBER: 351R-507SHAH SHEET DESIGNER: DAVE CARDELLO CUSTOMER RESIDENCE: TEL. (425) 922-8664 APN #: 6940587 ---- (415) 580-6920 ex3 SIGNAGE PV-5.0 ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED WARNING! LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): NEC 2017: 690.5(C), NEC 2014: 690.5(C), NEC 2011: 690.5(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 25.00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2017: 690.56(C)(1)(a) 6" 3.5" LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2017: 690.12, NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE: MAXIMUM CIRCUIT CURRENT: MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED): VDC ADC ADC 480 30 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2017: 690.53, NEC 2014: 690.53, NEC 2011: 690.53 15