Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SB Item 5 - L Makeup signage
1 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 REV 2 REV 3 REV 4 REV 5 REV 6 REV 7 REV 8 INSTRUCTIONS WALL SIGNS, AWNINGS, PLEX FACED CHANNEL LETTERS, MAKE UP BRUSHES FOR ENTRY, DIGITAL PRINTS LOGO FORMAT PROVIDED ON FILE CONVERSION TIME NA COLORS PROVIDED YES COLORS PMS CONVERSION DONE VINYL COLORS PROPOSED DONE SURVEY BUILDING OR OTHER FRONT SOUTH EAST WEST SURVEY MONUMENT/ POLE SIGN NA LANDLORD CRITERIA/ RESTRICTIONS NOT PROVIDED CITY CRITERIA/ RESTRICTIONS NOT PROVIDED 5-10-19 5-13-19 5-16-19 Sign company to provide property manager and tenant coordinator template of pattern for all penetrations, as they should be in mortar joints only. 5-28-19 Landlord Document Review _____ Concept Approved As Noted _____ Not Approved - Revise & Resubmit The concept approval granted herewith is for design intent only. Tenants and their contractors are fully responsible for compliance with all Federal, State, Local Codes & Ordinances, and the Design Review Board (Association) as well as compliance with Lease Agreements for this project. All work must be free of hazardous materials of any kind. If there is a discrepancy between the plans and the Lease, the Lease shall prevail. It is Tenant's responsibility to remove existing signage (if applicable), patch, repair and repaint the sign facade area to like-new condition. UL labels shall not be visible to the public view. Termination of electrical service shall be hidden from public view. Contact the Center's Property Manager to arrange for installation of signage, which should not interfere with Center’s open and operating tenants. Mounting - all penetrations to be in mortar joints ONLY and NOT Through the brick and sealed water-tight. Display of banners, flags, pennants, streamers, balloons, and inflatables are not allowed unless granted per Lease agreement or written authorization from Landlord. If you do not have any rights to the Center's monument and/or pylon sign, per the Lease, you will need to request permission from your Center's Property Manager. By: _____________________________________________ Brant Mullen, Sr. Tenant Coordinator Date Retail Properties of America Inc. 972-801-6008 or mullen@rpai.com 6/25/19 2 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 REV 2 REV 3 5-16-19 REV 4 REV 5 REV 6 REV 7 REV 8 5-10-19 5-13-19 SIGN-7 SIGN-8 SIGN-4 SIGN-5 SIGN-6SIGN-9 2 TWO SIGN-9 34.95 SF “L MAKEUP W/AWNING” CL W/ AWNING 6.5” X 7’ 11.46” “TAGLINE” FCO LETTERS 2’ 6”” X 7’ 0” “BANNERS” BLADE BANNERS SIGN-4 SIGN-5 SIGN-7 SIGN-8 5-28-19 _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19 40' 95' 190' 3 SIGN-4 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 REV 2 REV 3 REV 4 REV 5 REV 6 REV 7 REV 8 5-10-19 5-13-19 SCALE: 5/16” = 1’ SCOPE OF WORK: FABRICATE & INSTALL (1) SET OF LED CHANNEL LETTERS W/ AWNING EXTENSION 5-16-19 5-28-19 SPECIFICATIONS (CHANNEL LETTERS): 1..080 ALUMINUM LETTER FACES (POLISHED BRASS) 2..063 ALUMINUM RETURNS (POLISHED BRASS) 3..150” LEXAN BACKS (CLEAR) 4.GE LED ILLUMINATION (WHITE HALO) 5.ALL ALUMINUM AWNING VERTICAL EXTENSION (DK GREY TBD) ***SEE DETAILS PG 8 7..25” CNC ALUMINUM LETTERS (POLISHED BRASS) (PG 9) 1’ - 1 1 . 0 0 ” 0’ - 1 . 5 0 ” 1’ - 3 . 1 2 ” 0’ - 1 1 . 6 8 ” 15’-11.00” 16’-3.00” SIGN AREA: 12.32 SF _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19 4 SIGN-4 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 REV 2 REV 3 REV 4 REV 5 REV 6 REV 7 REV 8 SCALE: 5/16” = 1’ SCOPE OF WORK: FABRICATE & INSTALL (1) SET OF LED CHANNEL LETTERS W/ AWNING EXTENSION 5-10-19 5-13-19 SIGN AREA: 12.32 SF 5-16-19 SPECIFICATIONS (CHANNEL LETTERS): 1..080 ALUMINUM LETTER FACES (POLISHED BRASS) 2..063 ALUMINUM RETURNS (POLISHED BRASS) 3..150” LEXAN BACKS (CLEAR) 4.GE LED ILLUMINATION (WHITE HALO) 5.ALL ALUMINUM AWNING VERTICAL EXTENSION (DK GREY TBD) ***SEE DETAILS PG 8 7..25” CNC ALUMINUM LETTERS (POLISHED BRASS) (PG 9) 5-28-19 1’ - 1 1 . 0 0 ” 0’ - 1 . 5 0 ” 1’ - 3 . 1 2 ” 0’ - 1 1 . 6 8 ” 15’-11.00” 16’-3.00” 7’-9.37” 1’ - 7 . 0 0 ” _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19 5 SIGN-4 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 REV 2 REV 3 REV 4 REV 5 REV 6 REV 7 REV 8 EXISTING AWNING 5-10-19 5-13-19 SCALE: 5/16” = 1’ SCOPE OF WORK: FABRICATE & INSTALL (1) SET OF LED CHANNEL LETTERS W/ AWNING EXTENSION SURVEY REQUIRED REMOTE POWER ACCESS 5-16-19 **PAINT UPPER LIP POLISHED BRASS EXISTING AWNING REMOTE POWER ACCESS CONDUIT MUST BE CONCEALED WITHIN THE EXISTING AWNING CONDUIT MUST BE CONCEALED WITHIN THE EXISTING AWNING 5-28-19 SIGN AREA: 12.32 SF SPECIFICATIONS (CHANNEL LETTERS): 1..080 ALUMINUM LETTER FACES (POLISHED BRASS) 2..063 ALUMINUM RETURNS (POLISHED BRASS) 3..150” LEXAN BACKS (CLEAR) 4.GE LED ILLUMINATION (WHITE HALO) 5.ALL ALUMINUM AWNING VERTICAL EXTENSION (DK GREY TBD) ***SEE DETAILS PG 8 7..25” CNC ALUMINUM LETTERS (POLISHED BRASS) (PG 9) 1’ - 1 1 . 0 0 ” 0’ - 1 . 5 0 ” 1’ - 3 . 1 2 ” 0’ - 1 1 . 6 8 ” 15’-11.00” 16’-3.00” 7’-9.37” 1’ - 7 . 0 0 ” 3’ - 1 0 . 0 0 ” 4’ - 0 . 0 0 ” 0’ - 6 . 0 0 ” 0’ - 8 . 0 0 ” CHANNEL LETTERS ON CARRIER CABINET Disconnect Switch .080 Aluminum Face .063 Aluminum Returns .150 Lexan Backs Led’s Power Supply(s) Vented Power Supply Housing Non Corrosive Thru Bolts Weep Hole Carrier cabinet _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19Paint tie rods to match canopy 6 SIGN-5 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 5-10-19 REV 2 REV 3 REV 4 REV 5 REV 6 REV 7 REV 8 SIGN AREA: 4.31 SF SCALE: 5/16” = 1’ SCOPE OF WORK: FABRICATE & INSTALL (1) SET OF FCO LETTERS SPECIFICATIONS: 1.EXISTING AWNING TO BE PAINTED BY OTHERS (DARK GREY TBD) 2..25” CNC ALUMINUM LETTERS (POLISHED BRASS) 3.MOUNTED WITH ADHESIVE 0’ - 5 . 2 3 ” 0’ - 3 . 9 1 ” 7’-11.46” 0’-1.32” 0’ - 6 . 5 0 ” 5-13-19 5-16-19 5-28-19 _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19 to match signage backer construction 8 SIGN-7 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 5-10-19 REV 2 REV 3 REV 4 REV 5 REV 6 REV 7 REV 8 5-13-19 SIGN AREA: 45.66 SF SCALE: NTS SCOPE OF WORK: FABRICATE & INSTALL (1) SET OF LED CHANNEL LETTERS SPECIFICATIONS (CHANNEL LETTERS): 1..063 ALUMINUM LETTER BACKS (WHITE INTERIORS) 2..040 ALUMINUM RETURNS (POLISHED BRASS) 3.3/16” ACRYLIC FACES (WHITE) 4.1” JEWELITE TRIM CAP (POLISHED BRASS) 5.GE LED ILLUMINATION (WHITE) 6.DIRECT MOUNT 2’ - 3 . 0 0 ” 1’ - 9 . 4 4 ” 1’ - 4 . 6 0 ” 20’-3.50” 0’-4.00” DIRECT MOUNT CHANNEL LETTERS Disconnect switch 1” trimcap .040 aluminum returns 3/16” acrylic faces LED’s Power supply(s) Vented power supply housing Non corrosive flair anchors Weep hole 5-16-19 5-28-19 _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19 9 SIGN-8 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 5-10-19 REV 2 REV 3 REV 4 REV 5 REV 6 REV 7 REV 8 5-13-19 SIGN AREA: 36.09 SF SCALE: NTS SCOPE OF WORK: FABRICATE & INSTALL (1) SET OF LED CHANNEL LETTERS SPECIFICATIONS (CHANNEL LETTERS): 1..063 ALUMINUM LETTER BACKS (WHITE INTERIORS) 2..040 ALUMINUM RETURNS (POLISHED BRASS) 3.3/16” ACRYLIC FACES (WHITE) 4.1” JEWELITE TRIM CAP (POLISHED BRASS) 5.GE LED ILLUMINATION (WHITE) 6.DIRECT MOUNT DIRECT MOUNT CHANNEL LETTERS Disconnect switch 1” trimcap .040 aluminum returns 3/16” acrylic faces LED’s Power supply(s) Vented power supply housing Non corrosive flair anchors Weep hole 2’ - 0 . 0 0 ” 1’ - 7 . 0 6 ” 18’-0.50” 1’ - 2 . 7 6 ” 0’-4.00” 5-16-19 5-28-19 _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19 10 SIGN-9 100 STATE STREET SOUTHLAKE, TX DRAWING NUMBER T14252 INITIAL DATE 5-7-19 REV 1 5-10-19 REV 2 REV 3 REV 4 5-28-19 REV 5 REV 6 REV 7 REV 8 5-13-19 SIGN AREA: 17.5 SFSCOPE OF WORK: FABRICATE & INSTALL (2) BANNERS (BLADE STYLE PROTRUSION) SPECIFICATIONS : 1.13 OZ DOUBLE SIDED PRINTED BANNERS WITH POLE POCKETS 2.POLE MOUNTING ARMS & PLATES (BLACK) 2’-6.00”2’-6.00” 7’ - 0 . 0 0 ” 3’-0.00” 0’ - 2 . 0 0 ” 0’ - 4 . 0 0 ” 3’-0.00”0’-8.00” 0’ - 8 . 0 0 ” 5-16-19 APPROVED PENDING CITY APPROVAL _____ Approved as Noted (AAN) ___________________________ Brant Mullen Date 6/25/19 Bolt pattern to match mortar pattern