Loading...
Item 7Case No. ZA19-0043 S T A F F R E P O R T August 30, 2019 CASE NO: ZA19-0043 PROJECT: Site Plan for Rockenbaugh Elementary School EXECUTIVE SUMMARY: On behalf of Carroll ISD, Hart Gaugler & Associates is requesting approval of a Site Plan for Rockenbaugh Elementary School on property described as Lot 1, Block 60, Timarron Addition, an addition to the City of Southlake, Tarrant County, Texas and located at 301 Byron Nelson Parkway, Southlake, Texas. Current Zoning: “R-PUD” Residential Planned Unit Development District. SPIN Neighborhood #9. DETAILS: This project is located on the east side of Byron Nelson Parkway, just south of Zena Rucker Road. The purpose of this item is to gain approval for the construction of approximately 10,467 square feet of additional classroom space, modify driveways, and add parking spaces and covered walkways. The proposed site plan also includes the relocation of existing playground areas and shade structures. As part of the plan, the traffic circulation is being adjusted to allow more on site stacking. This is being done through the addition of pavement along the south side of the property. Traffic will be able to double stack and merge into one lane after the proposed pick up area. In the middle of the site, a left turn lane for busses only is proposed. This will be gated to prevent neighborhood traffic from entering the site. A Traffic Circulation Memo has been submitted by the applicant and provided with the meeting packet materials for review. The school currently only has five (5) busses servicing the site so traffic will be minimal. The applicant has indicated that bus traffic is limited to southbound traffic only. On the north side of the parking lot, the applicant is proposing to add 63 parking spaces. During special events, this will reduce the amount of parking taking place in the neighborhoods. This new parking will also plan for a future connection to Zena Rucker Road. Case No. ZA19-0043 Site Data Summary Existing Zoning R-PUD Land Use Designation Public/Semi-Public Lot Acreage 15.357 Existing Building Footprint 77,523 Proposed Building Footprint 98,901 Required Parking 149 spaces Existing Parking 161 spaces Proposed Parking 224 spaces Existing Impervious Coverage 34.6% Proposed Impervious Coverage 40.2% VARIANCE REQUESTS: Building Articulation – variance to requirements in Zoning Ordinance No. 480, as amended, for horizontal and vertical articulation, allowing building addition as shown on the proposed elevations. The building elevations are in alignment with the existing buildings on campus. The addition will match aesthetic and detailing. Landscaping – variance to Landscape Ordinance No. 544-B, Sections 3.3 and 3.4, requesting relief from additional interior landscape requirements and additional landscape requirements relating to the increase in parking. Tree Preservation – variance to Tree Preservation Ordinance No. 585-E; requesting that any trees impacted by the building addition or additional parking will not be mitigated. The resulting overall preservation is approximately 89.75%. Bufferyards – variance to Zoning Ordinance No. 480, as amended, Section 42, to allow existing bufferyards to remain. Where bufferyards are impacted by new site parking, requesting that any trees removed not be mitigated. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Approval of a Site Plan ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Site Plan Review Summary No. 2, dated August 29, 2019 (D) Surrounding Property Owners Map and Responses Full Size Plans (for Commission and Council members only) Presentation Narrative Plans Traffic Circulation Memo SPIN Report STAFF CONTACT: Dennis Killough (817) 748-8072 Lorrie Fletcher (817) 748-8069 Case No. Attachment A ZA19-0043 Page 1 BACKGROUND INFORMATION OWNER: Carroll ISD APPLICANT: Hart Gaugler & Associates PROPERTY SITUATION: 301 Byron Nelson Parkway LEGAL DESCRIPTION: Lot 1, Block 60, Timarron Addition LAND USE CATEGORY: Public / Semi-Public CURRENT ZONING: “R-PUD” – Residential Planned Unit District HISTORY: The Site Plan for Rockenbaugh Elementary School was approved by the City on September 3, 1996. (ZA96-086) A Revised Site Plan adding square footage to the building was approved on June 1, 1999. (ZA99-043) A Revised Site Plan adding a 400 square foot (20’ x 20’) Shade Structure (standing seam metal roof) was approved August 15, 2000. (ZA00-083) A Revised Site Plan adding approximately 2,532 square feet in shade structures (cloth type roofing material) was approved August 5, 2008. (ZA08-054) SOUTHLAKE 2035 PLAN: Consolidated Future Land Use Plan The 2035 future land use designation for the site is Public / Semi Public. Public/Semi-Public areas are suitable for a wide range of public, civic, and religious uses, such as government offices and facilities, public and private schools, churches and related facilities (including parsonage and parochial schools), cemeteries, and Public Parks/Open Space uses in conjunction with these developments. PATHWAYS MASTER PLAN: A 6 foot wide sidewalk is currently constructed along the east side of Bryon Nelson Parkway. TREE PRESERVATION AND LANDSCAPE: The applicant has requested a variance to allow for approximately 31 trees to be removed, being approximately 27.72% of the existing tree canopy without mitigation. The resulting overall preservation is approximately 89.75%. The applicant is also requesting that any landscaping requirements as a result of the building addition or additional parking be waived. Case No. Attachment A ZA19-0043 Page 2 CITIZEN INPUT: A SPIN meeting was held for this project on August 13, 2019. STAFF COMMENTS: Attached is Site Plan Review Summary No. 2, dated August 29, 2019. VARIANCE APPROVAL CRITERIA: Section 43 Overlay Zones III. RESIDENTIAL ADJACENCY STANDARDS APPLICABLE 43.10 The following residential adjacency standards shall apply to all non-single family residential buildings or uses located within the Corridor Overlay Zone, the Village Center, and those buildings and/or uses lying within four hundred feet (400') of single family residential property (See Development Regulations in Section 43.13a) and to all non-single family residential buildings and/or uses located within two hundred feet (200’) of property being within the “MH” Manufactured Housing District and also having a low density or medium density residential land use designation according to the Land Use Plan (See Development Regulations in Section 43.13b). (as amended by Ord. 480-QQ) These standards are in addition to the development regulations applicable to the underlying zoning district and the corridor overlay zone (where applicable). When any requirements in this section are in conflict with any other requirements for the underlying zoning district, the more stringent requirements shall apply. 43.13 DEVELOPMENT REGULATIONS: a. In addition to the development regulations set forth in the underlying zoning district, a plan meeting the requirements set forth in subparagraph 43.9a of this section and meeting the following additional development regulations shall be required to be submitted for any use or building that develops within 400 feet of single family residential properties. When applicable, line-of-sight drawings shall be submitted with the application to assess issues of visibility. (4) Facade Articulation: On all facades the following horizontal and vertical articulation must be met (see Exhibit 43-A for clarification). i. Horizontal Articulation: No building facade shall extend greater than three (3) times the wall’s height without having a minimum off-set of 15% of the wall’s height, and such off-set shall continue for a minimum distance equal to at least 25% of the maximum length of either adjacent plane. ii. Vertical Articulation: No horizontal wall shall extend for a distance greater than three (3) times the height of the wall without changing height by a minimum of 15% of the wall’s height, and such height change shall continue for a minimum distance equal to at least 25% of the maximum length of either adjacent plane. Variances - At the time of review of any required Concept Plan or Site Plan, the City Council may grant variances to the development regulations set forth. 1. To receive a variance, the applicant must demonstrate one of the following: Case No. Attachment A ZA19-0043 Page 3 (a) A variance will reduce the impact of the project on surrounding residential properties; or (b) Compliance with this ordinance would impair the architectural design or creativity of the project; or (c) A variance is necessary to assure compatibility with surrounding developed properties; or (d) The proposed construction is an addition to an existing project that does not meet the requirements of this ordinance. 2. The City Council may grant a variance by an affirmative vote of a majority of the City Council members present and voting on the matter. In order to grant a variance, the City Council must determine that a literal enforcement of the regulations will create an unnecessary hardship or a practical difficulty for the applicant; that the situation causing the unnecessary hardship or practical difficulty is unique to the affected property and is not self-imposed; that the variance will not injure and will be wholly compatible with the use and permitted development of adjacent properties; and that the granting of the variance will be in harmony with the spirit and purpose of this ordinance. 3. If a variance application is denied by the City Council, no other variance of like kind relating to the same project or proposed project shall be considered or acted upon by the City Council for a period of six (6) months subsequent to the denial. Case No. Attachment B ZA19-0043 Page 1 Case No. Attachment C ZA19-0043 Page 1 SITE PLAN REVIEW SUMMARY Case No.: ZA19-0043 Review No.: One Date of Review: 08/29/19 Project Name: Site Plan – Rockenbaugh Elementary Addition APPLICANT: Hart Gaugler & Associates OWNER: Carroll ISD John Blacker John Haugen 12801 N. Central Expressway 2400 N. Carroll Ave. Phone: 972-239-5111 Phone: 817-949-8222 Email: jblacker@hartgaugler.com Email: john.haugen@southlakecarroll.edu CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 8/19/19 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT THE APPROPRIATE STAFF MEMBER. Planning Review Lorrie Fletcher Planner Phone: (817) 748-8069 Email:lfletcher@ci.southlake.tx.us 1. The property is located within an R-PUD and adjacent to residential property. The proposed addition will require compliance with Section 43, Overlay Zones, II Residential Adjacency Standards, of the Zoning Ordinance 480, as amended. This includes horizontal and vertical articulation and masonry requirements. Variance Requested 2. The applicant has requested variances for relief from the interior landscaping requirements and to allow the bufferyard landscape to remain as it currently exists. Variances Requested 3. The applicant has requested a variance for relief from tree removal mitigation. Variance Requested 4. Please include the existing tree cover calculations in %; the percentage of existing cover, the percentage of existing tree cover to be removed, and the percentage of existing tree cover to remain on the Tree Conservation Plan. * Please be aware when submitting for a building permit, any variation from the approved site plan, elevations and associated plans may require further City Council approval. * All development must comply with the underlying zoning district regulations. Tree Conservation/Landscape Review Keith Martin Landscape Administrator Case No. Attachment C ZA19-0043 Page 2 Phone: (817) 748-8229 E-mail: kmartin@ci.southlake.tx.us TREE CONSERVATION COMMENTS: 1. The applicant is requesting a variance to the Tree Preservation Ordinance for the removal of trees for the construction of the building addition and additional parking. The variance is requesting that the removal of trees not be required to be mitigated. The required tree preservation is based on the total percentage of existing tree cover on the property. But some of the trees were planted to meet the interior landscape and bufferyards regulations during previous development phases. Depending on what percentage of existing tree cover is on the site and what percentage of the tree cover is proposed to be preserved, a variance may not be need. Please include on the Tree Conservation Plan the existing tree cover calculations of the percentage of existing cover, the percentage of existing tree cover to be removed, and the percentage of existing tree cover to remain. * Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 – Existing Tree Cover Preservation Requirements Percentage of existing tree cover on the entire site Minimum percentage of the existing tree cover to be preserved* 0% – 20% 70% 20.1 – 40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-of-way as approved by City Council. For property sought to be zoned for the Downtown zoning district or a planned development zoning district, including an S-P-1 Site Plan, S-P-2 Site Plan, Transition, Rural Conservation, Planned Unit Development, or Employment Center zoning district, the City Council shall consider the application for a Conservation Analysis or Plan in conjunction with the corresponding development application (as established in Table 1.0). The Planning and Zoning Commission shall review the application and make a recommendation to the City Council regarding the application. The City Council shall approve the Plan or Analysis if the Council finds that the Plan or Analysis provides for the: i. placement of building pads, parking areas, driveways, streets, and utility easements so as to maximize the preservation of environmental features of the property including mature tree stands, natural creeks and ponds, and significant grades; ii. maximizes the preservation of tree cover preservation areas indicated on the Environmental Resource Protection Map; Case No. Attachment C ZA19-0043 Page 3 iii. maximizes the preservation of existing tree stands with the potential to buffer residential areas from the noise, glare, and visual effects of nonresidential uses; iv. maximizes the preservation of existing trees, if any, adjoining a natural or man-made drainage creek; v. maximizes the preservation of existing protected trees along rural roadways and other streets as identified and prioritized in the Street Typology designation; and vi. mitigation of altered trees through proposed tree replacement procedures pursuant to this Ordinance. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constr ucted do not conflict with existing trees intended to be preserved. LANDSCAPE COMMENTS: * The applicant is requesting a variance to the Landscape Ordinance interior landscape and parking lot requirements, and the Bufferyards Regulations. No additional or replacement landscaping is proposed. Interior Landscape and Parking Landscape Requirements: Existing buildings: Buildings in existence on the effective date of this ordinance shall be considered legally nonconforming as it pertains to this ordinance. New construction greater in size than 30% of the existing building or greater than 5,000 square feet shall require compliance with this ordinance as it applies to the entire square footage of the existing building and proposed addition. New construction intended to increase the square footage by less than 30% of the existing building or less than 5,000 square feet shall be required to meet the requirements herein only as it pertains to the square footage of the new construction. All parking planter islands in parking areas shall contain a minimum of one (1) canopy tree with the remaining area in shrubs, ground cover, ornamental grasses or seasonal color. Planter islands which have light poles for lighting the parking areas may substitute two (2) understory/accent trees for the required canopy tree. Parking lot islands shall have a minimum width of 12’ back-to-back if curbed or 13’ edge-to- edge if no curb is intended and shall be equal to the length of the parking stall. Bufferyard Regulations Requirement: The proposed building addition exceeds 5000 square feet. New construction which increases the square footage of the existing building by thirty percent (30%) or greater than or which exceeds 5,000 square feet shall be required to meet the bufferyard requirements herein. * Indicates informational comment. Case No. Attachment C ZA19-0043 Page 4 # Indicates required items comment. Public Works/Engineering Review Steven Anderson, P.E., CFM Deputy City Engineer Phone: (817) 748-8101 E-mail: sanderson@ci.southlake.tx.us GENERAL COMMENTS: 1. This review is preliminary. Additional requirements may be necessary with the review of civil construction plans. SITE PLAN: 1. The new drive is shown as fire lane; the curb returns will need to have 20 ft. radii. DRAINAGE COMMENTS: 1. Both DMAPs need to show flow arrows and the drainage systems. * Discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance No. 605. WATER/SEWER COMMENTS: 2. The water line to be abandoned must have the ends plugged if left in place. INFORMATIONAL COMMENTS: * Submit 22”x34” civil construction plans and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. Please allow 15 business days for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City’s website: http://www.cityofsouthlake.com/PublicWorks/engineeringdesign.asp * Provide Stormwater Pollution Prevention Plan (SWPPP) per TXR150000. The plan must include all required elements in Part III, Section F of the permit. The Environmental Coordinator will review the SWPPP. For instructions on how to complete the review of the SWPPP please refer to the Stormwater Management for Construction Sites in: https://www.cityofsouthlake.com/2237/Stormwater-Management-for-Construction-S. SWPPP shall be submitted by second review of the civil construction plans. * Retaining walls greater than 4-feet including the footing shall require structural plans prepared by a registered engineer in the State of Texas. Retaining walls shall require a permit from the Building Inspections Department prior to construction. * Any hazardous waste being discharged must be pretreated per Ordinance No. 836. Public Works/Traffic Review Stephanie Taylor Case No. Attachment C ZA19-0043 Page 5 Transportation Manager Phone: (817) 748-8216 E-mail: staylor@ci.southlake.tx.us Site Plan: 1. Pending approval from the Fire Department, position the speed table near the front of the school so that it is more centered on the sidewalk. 2. The existing speed bump will no longer be needed if the proposed speed table is installed. 3. Consider using the speed table as a raised crosswalk, which has crosswalk markings across the level surface. 4. Provide details regarding dimensions and markings for proposed speed tables. 5. Creating a bus entrance that is more offset from Parkwood would do more to deter through movements from the neighborhood than the proposed curvature. Landscape Plan: 6. Add the following to the maintenance note: “Per AASHTO’s recommendations in the “A Policy on Geometric Design of Highways and Streets,” the landscaping shall not obstruct sight distance for left turning vehicles (minimum 225’ feet) or for right turning vehicles (minimum 195’) from the site’s driveways. Circulation Study: 7. Refer to the preferred alternative as Option 4 either in the section title or the first sentence of the section. It is referred to as Option 4 in the third paragraph, but this reference would be clearer were it placed closer to the beginning of the section. Fire Department Review Kelly Clements Fire Marshal Phone: (817) 748-8233 E-mail: kclements@ci.southlake.tx.us GENERAL COMMENTS: No comments based on submitted information. General Informational Comments: * A SPIN meeting was held for this project August 13, 2019. * No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. * All mechanical equipment must be screened of view right-of-ways and residential properties in accordance with the Zoning Ordinance No. 480, as amended. Case No. Attachment C ZA19-0043 Page 6 * All lighting must comply with the Lighting Ordinance No. 693, as amended. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * Through the wholesale water customer contract with the City of Fort Worth, all new water connections are required to pay the City of Fort Worth impact fee. The City of Fort Worth impact fee assessment is based on the final plat recordation date and building permit issuance. The applicant is encouraged to review the City of Fort Worth's assessment and collection of Impact Fees Guide to determine the fee amount. * Development must comply with all requirements in Zoning Ordinance No. 480, Section 43, Overlay Zones. * Masonry materials shall mean and include brick, stucco, plaster, cement, concrete tilt wall, stone, rock or other masonry material of equal characteristics. Stucco and plaster shall only be considered a masonry material when applied using a 3-step process over diamond metal lath mesh to a 7/8th inch thickness or by other processes producing comparable cement stucco finish with equal or greater strength and durability specifications. Synthetic products (e.g., EIFS –exterior insulation and finish systems, hardi plank, or other materials of similar characteristics) shall not be considered a masonry material. * Development must comply with all requirements in Zoning Ordinance No. 480, Section 33.21, Building Color Standards for Non-Residential Buildings. * The applicant should be aware that prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. * Denotes Informational Comment Case No. Attachment D ZA19-0043 Page 1 SURROUNDING PROPERTY OWNERS Owner Zoning Physical Address Acreage Response 1. WHITSON, STEVEN K RPUD 603 PARKWOOD DR 0.24 NR 2. OBREGON, TROY RPUD 605 PARKWOOD DR 0.31 NR 3. TIMARRON OWNERS ASSN INC RPUD 400 BYRON NELSON PKWY 0.70 NR 4. BERGER, MICHAEL RPUD 403 PARKWOOD CT 0.35 NR 5. POSPISIL, MARK RPUD 405 PARKWOOD CT 0.29 NR 6. TIMARRON OWNERS ASSN INC RPUD 451 BYRON NELSON PKWY 0.21 NR 7. TIMARRON OWNERS ASSN INC RPUD 700 GREYMOOR PL 5.78 NR 8. THE HORNYAK FAMILY LIVING TRUS RPUD 410 PARKWOOD CT 0.63 NR 9. DOWNEY, DAVID RPUD 701 GREYMOOR PL 0.33 NR 10. ZHOU, LILIN RPUD 705 GREYMOOR PL 0.27 NR 11. OBERDICK, JONATHAN RPUD 707 GREYMOOR PL 0.29 NR 12. PIGGOTT, JULIE RPUD 703 GREYMOOR PL 0.28 NR 13. MCDEVITT, COLIN RPUD 709 GREYMOOR PL 0.28 NR 14. ADMA, SUMANA RPUD 711 GREYMOOR PL 0.26 NR 15. REILLEY, TIMOTHY RPUD 713 GREYMOOR PL 0.26 NR 16. REID, CHARLES B RPUD 715 GREYMOOR PL 0.25 NR 17. SWOYER, RANDALL L RPUD 717 GREYMOOR PL 0.25 NR 18. DOTSON, PAUL J RPUD 719 GREYMOOR PL 0.25 NR 19. HOLTZ, KEITH M RPUD 721 GREYMOOR PL 0.27 NR 20. WOLF, PAUL RPUD 723 GREYMOOR PL 0.26 NR 21. GURUNATHAN, SHANKAR RPUD 725 GREYMOOR PL 0.28 NR Case No. Attachment D ZA19-0043 Page 2 22. QURESHI, AIJAZ H RPUD 727 GREYMOOR PL 0.24 NR 23. HUNT, BRYAN T RPUD 729 GREYMOOR PL 0.32 NR 24. SOUTHLAKE, CITY OF CS 307 PARKWOOD DR 12.69 NR 25. RCCK ENTERPRISES LLC O1 200 PECAN CREEK DR 0.91 NR 26. DAR PROPERTIES THIRTEEN LLC RPUD 600 ZENA RUCKER RD 0.99 NR 27. MILILANI INV ZENA LLC RPUD 601 ZENA RUCKER RD 1.07 NR 28. HCP CRS2 LTACH-BAYLOR SOUTHLAK SP1 731 E SOUTHLAKE BLVD 4.52 NR 29. DEVANE CLARKE PARTNERSHIP LTD SP2 731 ZENA RUCKER RD 2.30 NR 30. CARROLL, ISD RPUD 301 BYRON NELSON PKWY 15.60 NR 31. RUCKER, ZENA SULLIVAN TR AG 650 S CARROLL AVE 49.35 NR 32. RUCKER, ZENA SULLIVAN TR RPUD 317 MATTHEWS CT 0.50 NR 33. LANDLOCK LLC RPUD 304 MATTHEWS CT 0.45 NR 34. LANDLOCK LLC RPUD 308 MATTHEWS CT 0.49 NR 35. LANDLOCK LLC RPUD 312 MATTHEWS CT 0.50 NR 36. RUCKER, ZENA SULLIVAN TR RPUD 316 MATTHEWS CT 0.52 NR 37. LANDLOCK LLC RPUD 300 MATTHEWS CT 0.31 NR Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Thirty-seven (37) Responses Received 200’: None (0)