Item 6A and 6B - PresentationZoning Change and Site Plan
First National Bank
Preliminary Plat –La Paloma Addition
Items 6A and 6B ZA19-0011 and ZA19-0015
ZA19-0011 and ZA19-0015
Owner: 114 La Paloma Holdings, LLC
Applicant:SLI Group, Inc.
Requests:1)Approval of a Zoning Change and Site Plan from “AG”Agricultural
District to “S-P-1”Detailed Site Plan District to develop a three-story,
approximately 16,000 square foot building for First National Bank on
approximately 2.2 acres of an approximately 6.965 acre tract.(Item 6A)
2)Approval of a Preliminary Plat for Lots 1 and 2,Block 1,La Paloma
Addition for the entire 6.965 acre tract.(Item 6B)
Location:2001 Shady Oaks Dr.
Aerial View
2.2 acres
Aerial View
Note:Lot E1 (Old Orchard
Country Estates)was
subdivided in 2002 (City Case
ZA01-140)based on the
“new”alignment of Shady
Oaks Dr.
2001 Shady Oaks Dr. –Future Land Use
Optional Future Land Use
Site
Multi-Tenant
Office Overlay
The Multi-Tenant Office category is a commercial overlay category designed and intended for the use of high -quality, medium to
large-scale office buildings of 2-4 stories that may be build-to-suit or speculative (“spec”) built. These buildings are less prominent
than high-rise office with floor layouts that are designed for maximum user flexibility.
Master Pathways Plan
Site
Master Thoroughfare Plan
Site
2001 Shady Oaks Dr. –Zoning
1st Reading Conditions May 21, 2019
City Council 1st Reading Conditions of Approval Applicant’s Response
Noting that the driveway access onto Shady Oaks Dr.has been
removed.
No driveway access onto Shady Oaks is proposed on the revised
plans.
Noting that prior to 2nd Reading the applicant will provide a
revised parking plan moving the parking along the west side of the
property closest to Shady Oaks Dr.to be relocated along S.H.114
with the goal of not removing mature or large trees to further the
goal of increasing the overall tree preservation.
Revised plans have been submitted with 10 parking spaces
relocated along S.H.114 and 2 spaces eliminated with 3 spaces
now shown on the west side of the property where no trees
exist.Cross access to the property to the south is shown.The
percentage of existing canopy to be preserved has increased
from 30.80%to 40.95%.
Noting the applicant is planting additional canopy trees along or
close to Shady Oaks Dr.
A revised Landscape Plan has been submitted and was under
review when the packet was finalized.
Noting the buffer wall is being approved as an evergreen
vegetative screening and not a masonry wall.
The alternative Landscape Plan with a masonry wall has been
removed.
Noting the applicant will provide additional details as to lighting of
the building and the parking lot prior to 2nd Reading.
Additional lighting details are to be submitted after the meeting
packet is finalized.Staff will send the revised plan separately.
Noting that prior to 2nd Reading the applicant will provide a
comprehensive concept plan for the rest of the property to the
south with possible cross access and connectivity.
A conceptual plan for the entire site will be submitted after the
meeting packet is finalized.Staff will send the rendering
separately.Cross access is shown on the revised plans.
Noting that prior to 2nd Reading the applicant will provide
renderings as to the entrances along S.H.114.A rendering of one of the entrances has been submitted.
Site Plan at 1st Reading May 21, 2019
Site Data Summary
Existing Zoning “AG”
Proposed Zoning “S-P-1”
Land Use Designation Office Commercial
Gross/Net Acreage 2.22 ac./2.01 ac.
Total Building Floor Area (Gross)
Floor Area by Use
General Office
16,000 s.f.
16,000 s.f.
Building Height/Number of Stories 50’ 5” / 3 stories
Open Space %38.3%
Impervious Coverage %61.7%
Total Parking Required 58
Total Parking Spaces Provided 58
15 parking spaces
Revised Site Plan
Site Data Summary
Existing Zoning “AG”
Proposed Zoning “S-P-1”
Land Use Designation Office Commercial
Gross/Net Acreage 2.22 ac./2.01 ac.
Total Building Floor Area (Gross)
Floor Area by Use
General Office
16,000 s.f.
16,000 s.f.
Building Height/Number of Stories 50’ 5” / 3 stories
Open Space %42.3%
Impervious Coverage %57.7%
Total Parking Required 58
Total Parking Spaces Provided 58
3 parking spaces
10 parking spaces relocated from the west
side of the site and 2 spaces eliminated
Trash receptacle
enclosure relocated
Cross access shown
Revised “S-P-1” Regulations
“S-P-1” zoning is based on the “O-2” Office District uses and regulations with the following exceptions:
Regulation “O-2” Office District “S-P-1” Regulation
Residential Setback
(Section 43)
No non-single family residential building may
encroach in the area above a slope of 4:1 from
any single-family residential property.
Allow the building to encroach into the 4:1
slope area as shown on the exhibit on the
Site Plan.
Trash Receptacle
Enclosure
(Section 43)
No trash receptacles shall be located within 50’of
single family residential property and trash
receptacles shall be located to the side or rear of
the principal building.
Allow the trash receptacle to be located
±44’from the SF-1A zoned property to the
west and allow the enclosure to be located
forward of the principal building.
Screening adjacent to “SF-
1A” property to the west 8’solid screen adjacent to residential property is
required in Sections 39.6(a)and 42.7(a)Allow a vegetative screen.
Bufferyards
(Section 42)Parking spaces are not permitted in bufferyard Allow 10 parking spaces to encroach into
the 25’Type ‘I’bufferyard along S.H.114.
Off Street Parking
(Section 35)
General office uses require 8 spaces for the first
1,000 sq.ft.of floor area and 1 space per 300 sq.
ft.after that.(58 spaces required)
Allow 56 parking spaces.
* Changes per revisions to parking since 1st Reading
Tree Conservation Plan Comparison
1st Reading 5/21
30.8% Preservation
2nd Reading 6/4
40.95% Preservation
Cross access shown
10 parking spaces relocated from
the west side of the site and 2
spaces eliminated
15 parking spaces
3 parking spaces
Tree Conservation Plan at 1st Reading May 21, 2019
Revised Tree Conservation Plan
Landscape Plan at 1st Reading May 21, 2019
Revised Landscape Plan
Conceptual Rendering -S.H. 114
S-P-1 Exhibit –Residential Setback
Modification to 4:1 slope setback requirement requested
No non-single family residential building may encroach in the area above a slope
of 4:1 from any single-family residential property.
Allow the building to encroach into the 4:1 slope area as shown on the exhibit
on the Site Plan.
S-P-1 Exhibit –Trash Receptacle
±56’
Trash Receptacle
Enclosure
No trash receptacles shall be located within 50’of single family residential
property and trash receptacles shall be located to the side or rear of the
principal building.
S-P-1 -Allow the enclosure to be located forward of the principal building.
Allow the trash receptacle to be located ±44’from the SF-1A zoned property
to the west.The trash receptacle has been relocated and it now meets the
50’setback requirement.
Right of Way Abandonment
Variance Requests
Driveway Ord. No. 634, as amended requires a stacking depth of 50’ for all
driveways. The applicant is requesting a variance to allow the following
stacking depths:
Minimum of 25’-0” on the North Drive at S.H. 114.
Minimum of 25’-0” on the South Drive at S.H. 114.
Variance Exhibit
±25’
±25’
Variance Request:
A minimum stacking depth of 50’ is required for all driveways. A variance to allow the
following stacking depths is requested:
Minimum of 25’-0” on the North Drive at S.H. 114.
Minimum of 25’-0” on the South Drive at S.H. 114.
Estimated Vehicle Traffic
East Elevation
Stone Stucco
Columns to be clad in stucco
West Elevation
Columns to be clad in stucco
StoneStucco
North Elevation
South Elevation
Columns to be clad in stucco
Preliminary Plat (Item 6B)
ZA19-0015 -Preliminary Plat presented at the March 21, 2019 P&Z
Commission meeting. The plat will be revised prior to the June 4, 2019
City Council meeting to conform to the revised Tree Conservation Plan
Google Street View of Site
Looking NE
Looking N
Looking S
Looking S
Google Street View of Site
Looking SW
Looking W
Looking E
Looking SE
P & Z Commission Motion
March 21, 2019; Approved (5-0) subject to the staff report dated March 15, 2019 and Site Plan Review Summary No. 3,
dated March 14, 2019;
•Approving Variance No. 1, which is to the Driveway Ordinance amending stacking depth, but not approving Variance
No. 2, which deals with the commercial access onto Shady Oaks, and not approving Variance No. 3, which allows for
a carte blanche 5’ sidewalk versus an 8’ sidewalk, and;
•Noting the applicant’s willingness to present a revised Site Plan to City Council that shifts the building and
impervious coverage in such a way that there is at least a 20’ buffer between Shady Oaks. Ln. and the beginning of
any type of impervious coverage on the lot;
•Also noting the applicant’s willingness to present a revised Site Plan that removes the five parking spaces that are
the furthest southwest and reallocate them in such a way that does not materially alter the landscape and tree
coverage that is otherwise presented, and;
•Presenting an option for a buffer, whether that is a vegetative organic buffer and/or a masonry type structure buffer
or wall and maybe both.
City Council 1st Reading Motion
May 21, 2019; Approved (6-1) subject to the staff report dated May 14, 2019 and Revised Site Plan Review Summary No. 5, dated
May 14, 2019,
•Granting the following variances as to stacking depth:
Driveway Ord. No. 634, as amended requires a stacking depth of 50’ for all driveways. The applicant is requesting a variance
to allow the following stacking depths:
To a minimum of 25’-0” on the North Drive at S.H. 114.
To a minimum of 25’-0” on the South Drive at S.H. 114.
•Noting that the driveway access onto Shady Oaks Dr. has been removed.
•Noting that prior to 2nd Reading the applicant will provide a revised parking plan moving the parking along the west side of the
property closest to Shady Oaks Dr. to be relocated along S.H. 114 with the goal of not removing mature or large trees to
further the goal of increasing the overall tree preservation.
•Noting the applicant is planting additional canopy trees along or close to Shady Oaks Dr.
•Noting the buffer wall is being approved as an evergreen vegetative screening and not a masonry wall.
•Noting the applicant will provide additional details as to lighting of the building and the parking lot prior to 2 nd Reading.
•Noting that prior to 2nd Reading the applicant will provide a comprehensive concept plan for the rest of the property to the
south with possible cross access and connectivity.
•Noting that prior to 2nd Reading the applicant will provide renderings as to the entrances along S.H. 114.
Questions?