Item 6A Plans87
9
8
SH
1
1
4
So
u
t
h
l
a
k
e
,
T
e
x
a
s
7
6
0
9
2
FI
R
S
T
N
A
T
I
O
N
A
L
B
A
N
K
ZA19-0011
TR
A
C
T
1
B
,
J
A
M
E
S
J
.
W
E
S
T
S
U
R
V
E
Y
,
A
B
S
T
R
A
C
T
N
O
.
1
6
2
0
,
SO
U
T
H
L
A
K
E
,
T
A
R
R
A
N
T
C
O
U
N
T
Y
,
T
E
X
A
S
ZONING CASE NO.
24
'
F
I
R
E
L
A
N
E
24' FI
R
E
L
A
N
E
24' FIRE LANE
24' FIRE LANE
3 STORY
BUILDING
56 PARKING SPACES
PROPOSED
25' TY
P
E
"
I
"
B
U
F
F
E
R
Y
A
R
D
1
0
'
T
Y
P
E
"
B
"
B
U
F
F
E
R
Y
A
R
D
10
'
T
Y
P
E
"
B
"
B
U
F
F
E
R
Y
A
R
D
TRACT SIZE:
96,510 SQ. FT.
2.22 ACRES
50' BU
I
L
D
I
N
G
S
E
T
B
A
C
K
10' TYPE "B" BUFFER YARD
EXISTING PROPERTY LINE
PROPOSED PROPERTY LINE
6,243 SQ.FT.
BUILDING TOTAL
16,000 SQ.FT.
FOOTPRINT
N 01°03'23" E 790.47'
S
8
7
°
3
5
'
2
1
"
E
25
.
0
4
'
S 01°03'21" W 324.09'
S 23°
3
3
'
4
4
"
E
2
2
2
.
5
6
'
N
8
8
°
5
6
'
0
1
"
W
2
9
3
.
9
9
'
Arc - 3
0
5
.
1
6
'
Radius
-
5
8
6
7
.
8
1
'
Delta
-
2
°
5
8
'
4
7
"
Chord
-
S
2
2
°
0
4
'
3
6
"
E
3
0
5
.
1
3
'
N
7
4
°
1
1
'
1
9
"
E
5
8
.
9
0
'
LOT E-1, BLOCK 1, OLD ORCHARD COUNTRY ESTATES
CABINET A, SLIDE 7777, P.R.T.C.T.
TRACT D
BLOCK 1, OLD ORCHARD COUNTRY ESTATES
VOLUME 388-118, PAGE 41, P.R.T.C.T.
11
4
P
A
L
O
M
A
H
O
L
D
I
N
G
S
,
L
L
C
(
R
E
M
A
I
N
D
E
R
)
IN
S
T
.
N
O
.
D
2
1
6
0
3
9
4
0
6
,
D
.
R
.
T
.
C
.
T
.
TRACT C
LOT E-2, BLOCK 1, OLD ORCHARD COUNTRY ESTATES
CABINET A, SLIDE 7777, P.R.T.C.T.
6" CO
N
C
R
E
T
E
5" CO
N
C
R
E
T
E
5" CO
N
C
R
E
T
E
6" CONCRETE
5" CONCRETE
6" CONCRETE
5" CONCRETE
7" CONCRETE
5" CONCRETE
6" CONCRETE
6" CONCRETE
5" CO
N
C
R
E
T
E
4" CO
N
C
R
E
T
E
4" CO
N
C
R
E
T
E
4" CO
N
C
R
E
T
E
4" CONCRETE
4" CO
N
C
R
E
T
E
4" CO
N
C
R
E
T
E
4" CO
N
C
R
E
T
E
BLDG.
ENTRANCE
BLDG.
ENTRANCE
30' BUILDING SETBACK
15' BUILDING SETBACK
15
'
B
U
I
L
D
I
N
G
S
E
T
B
A
C
K
1
5
'
B
U
I
L
D
I
N
G
S
E
T
B
A
C
K
HEIGHT 50'-5"
10
'
x
5
0
'
L
O
A
D
I
N
G
Z
O
N
E
SF1-A
SF-2
L.U.D. = FLOOD PLAIN
L.U.D. = LOW DENSITY RESIDENTIAL
BLOCK 1, OLD ORCHARD COUNTRY ESTATES
VOLUME 388-118, PAGE 41, P.R.T.C.T.
SF-2
L.U.D. = LOW DENSITY RESIDENTIAL
AG
L.
U
.
D
.
=
O
F
F
I
C
E
C
O
M
M
E
R
C
I
A
L
CURRENT OWNER:
NEILL ROSEMMA
NEILL KAY V GUNN
4812 BARKRIDGE TR
FORT WORTH, TX 76109-3212
CU
R
R
E
N
T
O
W
N
E
R
:
11
4
L
A
P
A
L
O
M
A
H
O
L
D
I
N
G
S
L
L
C
C/
O
M
R
M
I
K
E
M
I
L
L
S
12
0
7
S
W
H
I
T
E
C
H
A
P
E
L
B
L
V
D
S
T
E
1
5
0
SO
U
T
H
L
A
K
E
,
T
X
7
6
0
9
2
CURRENT OWNER:
ROSS KENNETH R
ROSS PAMELA POWELL
2050 SHADY OAKS DR
SOUTHLAKE, TX 76092
CURRENT OWNER:
JAMAL SYED
JAMAL SADIA AMBARIN
2000 SHADY OAKS DR
SOUTHLAKE, TX 76092
SF1-A
L.U.D. = LOW DENSITY RESIDENTIAL
CURRENT OWNER:
KOPPALA SRINIVASULU
POOSANAM SRIDEVI
1238 MINTO DR
IRVING, TX 75063
EXISTING
ASPHALT
RESIDENTIAL
DRIVEWAY
EXISTING
CONCRETE
RESIDENTIAL
DRIVEWAY
10' TYPE "F-1" BUFFER YARD
USE - GENERAL OFFICE
5"
C
O
N
C
R
E
T
E
10' ADDITIONAL BUFFER YARD
CENTERLINE OF R.O.W.
SH 11
4
F
R
O
N
T
A
G
E
R
O
A
D
SHADY O
A
K
S
D
R
I
V
E
R.O.W
.
V
A
R
I
E
S
(
3
0
0
'
-
0
"
T
O
5
0
0
'
-
0
"
)
60'-0" R.
O
.
W
.
W
.
D
O
V
E
R
O
A
D
8
8
'
-
0
"
R
.
O
.
W
.
8'-0" WIDE PATH
8'-0" WIDE PATH
8'-0" HIGH MASONRY SCREEN
5'-0" HIGH MASONRY SCREEN
5'-0" HIGH MASONRY SCREEN
5" CO
N
C
R
E
T
E
NORTH
SCALE: 1" = 30'-0"01 SITE PLAN
550 WESTLAKE PARK BLVD., SUITE 300
HOUSTON, TEXAS 77079
713-465-4650
www.sligroup.com
ARCHITECTURE PLANNING INTERIOR DESIGN
COPYRIGHTC
C
The information, ideas, designs, details, layouts, techniques, features, arrangements,
plans, sequences, dimensions, allowances, tolerances, conceptions, specifications,
intentions, technology or embodiments, as illustrated, arranged, displayed, noted,
recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to
tangible form hereon, either expressly, inherently or by implication, are the confidential
and proprietary information of SLI Design, Inc., and shall not be used for any purpose
other than the specific project or undertaking identified on the drawing title block or
legend for which they are and have been prepared by SLI Design, Inc. Any other
reproduction, disclosure or use of any portion of the confidential and proprietary
information of SLI Design, Inc., shall be a breach of the obligation of confidence created
by the acceptance of this drawing from SLI Design, Inc. for a specific project or
Contract. Any copying, duplicating, reproducing, utilization, alteration, modification,
revision or change to this drawing, is expressly prohibited unless done with the prior
written consent or approval of SLI Design, Inc., and shall not be undertaken without
receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., for
the limited purpose of complying with a specific Contract. The drawing remains the
property of SLI Design, Inc., and shall be returned upon request or completion of the
contract, unless specifically authorized by Contract, under which it was loaned.
PR
O
J
E
C
T
N
U
M
B
E
R
:
ISSUED FOR CLIENT APPROVAL
ISSUED FOR BIDDING
ISSUED FOR PERMIT
ISSUED FOR CONSTRUCTION
DATE
MARK DESCRIPTION DATE
PRINT DATE
DRAWING TITLE
DRAWN BY
CHECKED BY
APPROVED BY
SHEET NO.
REVISIONS
DESIGN, INC.
SITE PLAN
SP-1.00
CM
TB
TB
SITE PLAN DATA SUMMARY TOTAL
EXISTING ZONING AG
PROPOSED ZONING S-P-1
LAND USE DESIGNATION:OFFICE / COMMERCIAL
GROSS ACREAGE:2.2 ACRES (96,563 SQ.FT.)
NET ACREAGE:2.01 ACRES (87,530 SQ.FT.)
NUMBER OF PROPOSED LOTS 1
PERCENT OF SITE COVERAGE:6.87%
AREA OF OPEN SPACE 36,991 SQ.FT.
PERCENT OF OPEN AREA:42.3%
AREA OF IMPERVIOUS COVERAGE 50,539 SQ.FT.
PERCENTAGE OF IMPERVIOUS COVERAGE 57.7%
TOTAL BUILDING AREA (FOOTPRINT IN SQ. FT.)6,243 SQ. FT.
NUMBER OF STORIES 3
MAXIMUM BUILDING HEIGHT 90' ALLOWED
(50'-5" SHOWN)
PROPOSED FLOOR AREA:16,000 SQ. FT.
PROPOSED FLOOR AREA BY USE:
GENERAL OFFICE 16,000 SQ. FT.
PARKING SPACES REQUIRED:58
PARKING SPACES PROVIDED:56
STANDARD 53
HANDICAP 3
TOTAL 53
REQUIRED LOADING SPACES 1 (10'x50')
PROVIDED LOADING SPACES 1 (10'x50')
AREA OF OUTSIDE STORAGE 0
PERCENTAGE OF OUTSIDE STORAGE 0%
ANTICIPATED SCHEDULE OF DEVELOPMENT
CONSTRUCTION START DATE 6/10/2019
CONSTRUCTION END DATE 6/10/2020
RE:05/SP-2.00
RE:03/SP-2.00
RE:02/SP-2.00
RE:01/SP-2.00 RE:07/SP-2.00
RE:15/SP-2.00
SCALE: NOT TO SCALE05VICINITY MAP
SCALE: 1'-0" = 30'-0"06 BUILDING SETBACK
RE
S
I
D
E
N
T
I
A
L
P
R
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
4:1 SLOPE
RE:21/SP-2.00
DESIGNATED LANDSCAPING AREA
DESIGNATED FIRE LANE OVER 6" CONCRETE
4", 5", 6", OR 7" CONCRETE PAVEMENT
SCALE: NOT TO SCALE07LEGEND
AREA OF PROPERTY IN R.O.W.
RE:02/SP-1.10
RE:03/SP-1.10
TRACT 1B, JAMES J. WEST
SURVEY, ABSTRACT NO. 1620,
SOUTHLAKE, TARRANT
COUNTY, TEXAS
SCALE: NOT TO SCALE08GENERAL NOTES
1. ALL MECHANICAL EQUIPMENT TO SCREENED FROM
VIEW PER ZONING ORDINANCE NO.480, AS AMENDED.
2. ALL LIGHTING TO COMPLY WITH LIGHTING
ORDINANCE NO. 693, AS AMENDED.
3. DEVELOPMENT TO COMPLY WITH ZONING
ORDINANCE NO.480, SECTION 43, OVERLAY ZONES.
4. ALL PAINTED PARKING STRIPING SHALL BE 4" WHITE.
5. SOIL POISON FOR WEEDS UNDER BUILDING PAD
6. DENOTE FIRE LANE WITH RED STRIPE ON CURB AND
WHITE "FIRE LANE- NO PARKING" STENCIL SPACED
NO MORE THAN 25 FEET.
7. ALL LIGHTING MUST COMPLY WITH THE LIGHTING
ORDINANCE NO. 693, AS AMENDED WITH REGARD TO
TYPE OF LIGHTING, INTENSITY, GLARE AND
SPILL-OVER.
CONNECTING DRIVEWAY
DEFINED IN CROSS
ACCESS EASEMENT
AGREEMENT TO BE
SIGNED AT CLOSING
87
9
8
SH
1
1
4
So
u
t
h
l
a
k
e
,
T
e
x
a
s
7
6
0
9
2
FI
R
S
T
N
A
T
I
O
N
A
L
B
A
N
K
ZA19-0011
TR
A
C
T
1
B
,
J
A
M
E
S
J
.
W
E
S
T
S
U
R
V
E
Y
,
A
B
S
T
R
A
C
T
N
O
.
1
6
2
0
,
SO
U
T
H
L
A
K
E
,
T
A
R
R
A
N
T
C
O
U
N
T
Y
,
T
E
X
A
S
ZONING CASE NO.NORTH
SCALE: 1" = 30'-0"01 SITE PLAN
EXISTING PROPERTY LINE
PROPOSED PROPERTY LINE
N 01°03'23" E 790.47'
S
8
7
°
3
5
'
2
1
"
E
25
.
0
4
'
S 01°03'21" W 324.09'
S 23°
3
3
'
4
4
"
E
2
2
2
.
5
6
'
N
8
8
°
5
6
'
0
1
"
W
2
9
3
.
9
9
'
Arc - 3
0
5
.
1
6
'
Radius
-
5
8
6
7
.
8
1
'
Delta
-
2
°
5
8
'
4
7
"
Chord
-
S
2
2
°
0
4
'
3
6
"
E
3
0
5
.
1
3
'
N
7
4
°
1
1
'
1
9
"
E
5
8
.
9
0
'
LOT E-1, BLOCK 1, OLD ORCHARD COUNTRY ESTATES
CABINET A, SLIDE 7777, P.R.T.C.T.
TRACT D
BLOCK 1, OLD ORCHARD COUNTRY ESTATES
VOLUME 388-118, PAGE 41, P.R.T.C.T.
11
4
P
A
L
O
M
A
H
O
L
D
I
N
G
S
,
L
L
C
(
R
E
M
A
I
N
D
E
R
)
IN
S
T
.
N
O
.
D
2
1
6
0
3
9
4
0
6
,
D
.
R
.
T
.
C
.
T
.
TRACT C
LOT E-2, BLOCK 1, OLD ORCHARD COUNTRY ESTATES
CABINET A, SLIDE 7777, P.R.T.C.T.
SF1-A
SF-2
L.U.D. = FLOOD PLAIN
L.U.D. = LOW DENSITY RESIDENTIAL
BLOCK 1, OLD ORCHARD COUNTRY ESTATES
VOLUME 388-118, PAGE 41, P.R.T.C.T.
SF-2
L.U.D. = LOW DENSITY RESIDENTIAL
AG
L.
U
.
D
.
=
O
F
F
I
C
E
C
O
M
M
E
R
C
I
A
L
CURRENT OWNER:
NEILL ROSEMMA
NEILL KAY V GUNN
4812 BARKRIDGE TR
FORT WORTH, TX 76109-3212
CU
R
R
E
N
T
O
W
N
E
R
:
11
4
L
A
P
A
L
O
M
A
H
O
L
D
I
N
G
S
L
L
C
C/
O
M
R
M
I
K
E
M
I
L
L
S
12
0
7
S
W
H
I
T
E
C
H
A
P
E
L
B
L
V
D
S
T
E
1
5
0
SO
U
T
H
L
A
K
E
,
T
X
7
6
0
9
2
CURRENT OWNER:
ROSS KENNETH R
ROSS PAMELA POWELL
2050 SHADY OAKS DR
SOUTHLAKE, TX 76092
CURRENT OWNER:
JAMAL SYED
JAMAL SADIA AMBARIN
2000 SHADY OAKS DR
SOUTHLAKE, TX 76092
SF1-A
L.U.D. = LOW DENSITY RESIDENTIAL
CURRENT OWNER:
KOPPALA SRINIVASULU
POOSANAM SRIDEVI
1238 MINTO DR
IRVING, TX 75063
EXISTING
ASPHALT
RESIDENTIAL
DRIVEWAY
EXISTING
CONCRETE
RESIDENTIAL
DRIVEWAY
CENTERLINE OF R.O.W.
SH 11
4
F
R
O
N
T
A
G
E
R
O
A
D
SHADY O
A
K
S
D
R
I
V
E
R.O.W
.
V
A
R
I
E
S
(
3
0
0
'
-
0
"
T
O
5
0
0
'
-
0
"
)
60'-0" R.
O
.
W
.
W
.
D
O
V
E
R
O
A
D
8
8
'
-
0
"
R
.
O
.
W
.
550 WESTLAKE PARK BLVD., SUITE 300
HOUSTON, TEXAS 77079
713-465-4650
www.sligroup.com
ARCHITECTURE PLANNING INTERIOR DESIGN
COPYRIGHTC
C
The information, ideas, designs, details, layouts, techniques, features, arrangements,
plans, sequences, dimensions, allowances, tolerances, conceptions, specifications,
intentions, technology or embodiments, as illustrated, arranged, displayed, noted,
recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to
tangible form hereon, either expressly, inherently or by implication, are the confidential
and proprietary information of SLI Design, Inc., and shall not be used for any purpose
other than the specific project or undertaking identified on the drawing title block or
legend for which they are and have been prepared by SLI Design, Inc. Any other
reproduction, disclosure or use of any portion of the confidential and proprietary
information of SLI Design, Inc., shall be a breach of the obligation of confidence created
by the acceptance of this drawing from SLI Design, Inc. for a specific project or
Contract. Any copying, duplicating, reproducing, utilization, alteration, modification,
revision or change to this drawing, is expressly prohibited unless done with the prior
written consent or approval of SLI Design, Inc., and shall not be undertaken without
receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., for
the limited purpose of complying with a specific Contract. The drawing remains the
property of SLI Design, Inc., and shall be returned upon request or completion of the
contract, unless specifically authorized by Contract, under which it was loaned.
PR
O
J
E
C
T
N
U
M
B
E
R
:
ISSUED FOR CLIENT APPROVAL
ISSUED FOR BIDDING
ISSUED FOR PERMIT
ISSUED FOR CONSTRUCTION
DATE
MARK DESCRIPTION DATE
PRINT DATE
DRAWING TITLE
DRAWN BY
CHECKED BY
APPROVED BY
SHEET NO.
REVISIONS
DESIGN, INC.
DIMENSIONED SITE PLAN
SP-1.10
CM
TB
TB
NORTH
SPEED
LIMIT
45
SPEED
LIMIT
45
PROP
O
S
E
D
A r c - 3
R a d i u
D e l t
C h
5 6 '
SCALE: 1" = 30'-0"02 PROPOSED ENTRY
SCALE: 1" = 30'-0"03 PROPOSED ENTRY
SCALE: NOT TO SCALE05VICINITY MAP
PROP
O
S
E
D
DESIGNATED LANDSCAPING AREA
DESIGNATED FIRE LANE OVER 6" CONCRETE
4", 5", 6", OR 7" CONCRETE PAVEMENT
SCALE: NOT TO SCALE04LEGEND
AREA OF PROPERTY IN R.O.W.
/
1
4
S
P
-
2
.
0
0
/
1
4
S
P
-
2
.
0
0
/14 SP-2.0
0
/14 SP-2.0
0
RE:02/SP-1.10
RE:03/SP-1.10
87
9
8
SH
1
1
4
So
u
t
h
l
a
k
e
,
T
e
x
a
s
7
6
0
9
2
FI
R
S
T
N
A
T
I
O
N
A
L
B
A
N
K
ZA19-0011
TR
A
C
T
1
B
,
J
A
M
E
S
J
.
W
E
S
T
S
U
R
V
E
Y
,
A
B
S
T
R
A
C
T
N
O
.
1
6
2
0
,
SO
U
T
H
L
A
K
E
,
T
A
R
R
A
N
T
C
O
U
N
T
Y
,
T
E
X
A
S
ZONING CASE NO.
550 WESTLAKE PARK BLVD., SUITE 300
HOUSTON, TEXAS 77079
713-465-4650
www.sligroup.com
ARCHITECTURE PLANNING INTERIOR DESIGN
COPYRIGHTC
C
The information, ideas, designs, details, layouts, techniques, features, arrangements,
plans, sequences, dimensions, allowances, tolerances, conceptions, specifications,
intentions, technology or embodiments, as illustrated, arranged, displayed, noted,
recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to
tangible form hereon, either expressly, inherently or by implication, are the confidential
and proprietary information of SLI Design, Inc., and shall not be used for any purpose
other than the specific project or undertaking identified on the drawing title block or
legend for which they are and have been prepared by SLI Design, Inc. Any other
reproduction, disclosure or use of any portion of the confidential and proprietary
information of SLI Design, Inc., shall be a breach of the obligation of confidence created
by the acceptance of this drawing from SLI Design, Inc. for a specific project or
Contract. Any copying, duplicating, reproducing, utilization, alteration, modification,
revision or change to this drawing, is expressly prohibited unless done with the prior
written consent or approval of SLI Design, Inc., and shall not be undertaken without
receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., for
the limited purpose of complying with a specific Contract. The drawing remains the
property of SLI Design, Inc., and shall be returned upon request or completion of the
contract, unless specifically authorized by Contract, under which it was loaned.
PR
O
J
E
C
T
N
U
M
B
E
R
:
ISSUED FOR CLIENT APPROVAL
ISSUED FOR BIDDING
ISSUED FOR PERMIT
ISSUED FOR CONSTRUCTION
DATE
MARK DESCRIPTION DATE
PRINT DATE
DRAWING TITLE
DRAWN BY
CHECKED BY
APPROVED BY
SHEET NO.
REVISIONS
DESIGN, INC.
SITE ENLARGMENTS
SP-2.00
CM
TB
TB
25 ACCESSIBLE PARKING STALL SIGN
SCALE: NTS
NOTE:
BLUE PAINT
(SEE NOTE)
WHITE PAINT
3'
-
6
"
R=8 1/2"
3"
3'-6"
1 1/4"
7"
5
1
/
2
"
10
1
/
2
"
7"
6"
1'-6 1/4"
3"
1 1/4"
2"1/2"
3"
3"
2"
10
1
/
2
"
2'
-
0
"
KEY NOTES:
PAINT WHITE
QUIKRETE CONCRETE WHEEL STOP, 6FT OR
EQUAL
FIRE LANE AREAS SHALL BE PAINTED
RED.RE: SP10
DENOTE FIRE LANE WITH RED STRIPE ON
CURB AND WHITE "FIRE LANE- NO PARKING"
STENCIL SPACED NO MORE THAN 25 FEET.
01
02
03
5"H. X 7 1/2"W.
BUMPER
PRECAST CONCRETE
INTO PAVING
3/4" DOWELS EPOXY
FILL HOLES W/ EPOXY
SEE PLAN
23 WHEELSTOP
SCALE: NTS
SCALE: 1/8"=1'-0"01 SITE ENLARGEMENT
01
01
03
02
SCALE: 1/8"=1'-0"03 SITE ENLARGEMENT
SCALE: 1/8"=1'-0"04 KEYED NOTES
03
N
E
SCALE: 1/8"=1'-0"05 SITE ENLARGEMENT
SCALE: 1/8"=1'-0"02 SITE ENLARGEMENT
01
03
03
SCALE: 1/8"=1'-0"07 SITE ENLARGEMENT
SCALE: NTS15
GRASS OR
LANDSCAPE
AREA
2" PVC
SLEEVE AT
LANDSCAPE
AREAS,
RE:SP-1.0 or
L-1.0
2" SAND FILL
BROOM
FINISH
COARSE
TEXTURE
ROD AND
SEALANT
OVER
EXPANSION
FILLER
6" CURB
2" PVC
SLEEVE
6" CURB
2" PVC SLEEVE
CONCRETE
PAVING
RE:CIVIL
2" PVC SLEEVE AT
LANDSCAPE AREAS,
RE:SP-1.0 or L-1.0
SCALE: NTS11CURB AT SIDEWALK
SCALE: NTS12CURB AT GRADE
CONCRETE CURB
RAMP SLOPE NOT TO EXCEED 1:12
RAMP TO HAVE LIGHT REFLECTIVE VALUE AND
TEXTURE TO SIGNIFICANTLY CONTRAST WITH
ADJOINING PEDESTRIAN ROUTES.
SCORED CONCRETE RAMP WITH
GROOVES 1/4" DEEP, 3/4" WIDE
AND 2" APART. SLOPE TO
PREVENT ACCUMULATION OF
WATER.
CONCRETE SIDEWALK
ACCESSIBLE PARKING SIGN
SCALE: NTS13
CURBRAMP
17 ACCESSIBLE PARKING SIGN
SCALE: NTS
SLOTTED SQUARE TUBE
2,500 PSI CONCRETE
INTERNATIONAL SYMBOL OF
ACCESSIBILITY- BORDER &
LETTERING IN WHITE ON BLUE
BACKGROUND
12" X 18" - 16 GA. BONDERIZED
STEEL SIGN (VERIFY SIZE &
LETTERING W/ GOVERNING
AUTHORITY)
ADDITIONAL SIGN (12" X 6")
REQUIRED FOR VAN PARKING
SPACE - REF SITE PLAN
19 BOLLARD DETAILS
SCALE: NTS
#5 ROD
@36" O.C.
NEW 4"Ø GALVANIZED
BOLLARD FILL WITH
CONCRETE AND PAINT DARK
BRONZE
REINFORCED CONCRETE
ISLAND
RE:
CIVIL
#3 DOWELS @36" O.C.
#5 ROD CONTINUOUS
1:12
1:12 1:12 1:12
21 MONUMENT SIGN
SCALE: NTS
EIFS CAP
3
4" STUCCO OVER CMU
8" REINFORCED CMU BLOCK
RECESSED CAN LIGHT 2'-6" X 4'-0"
LINTEL OR BOND BEAM REQUIRED
FIRST NATIONAL BANK
SCALE: NTS24
4" DIA. PAINTED
PIPE BOLLARDS
4" DIA. PAINTED
PIPE BOLLARDS
8" CMU BLOCK
WITH STUCCO
VENEER
3/4" STUCCO OVER
METAL LATHE
EIFS CAP
RE:15/SP-2.00
3
4" STUCCO OVER FELT
PAPER WITH METAL
LATHE OVER TYVEK
STUCCO WRAP
8" CMU
EIFS CAP
RE:15/SP-2.00
EIFS BAND
RE:15/SP-2.00
EIFS BAND
RE:15/SP-2.00
3/4" STUCCO OVER
METAL LATHE
EIFS CAP
RE:15/SP-2.00
EIFS BAND
RE:15/SP-2.00
R PANELS; RE:A-6.00
FOR COLOR
4"x4" PAINTED TUBE
STEEL;
HEAVY DUTY PIVOT
HINGES
11
2"x 11
2" PAINTED
TUBE STEEL;
DUMPSTER ENCLOSURE
PLANSECTIONEIFS BAND
EIFS CAP
FRONT ELEVATION TYPICAL SIDE ELEVATION BACK ELEVATION
03
03
TYP
WALL OF BLDG
EDGE OF CURB
ROLL-UP CURB
SCALE: NTS14
LIGHT POLE BASE
1" GROUT
ANCHOR BOLTS
UNPAINTED/CONCRETE
LINE OF GRADE
ANCHOR BOLTS PER
MANUFACTURER'S SPECS
4 - #5'S VERTICAL
REINFORCEMENT WITH #3
TIES AT 10" O.C.
ROUND CONCRETE PIERS
SYMBOL TO BE CENTERED ON
WIDTH OF PARKING STALL -
SYMBOLS ARE REQ'D TO
CONTRAST W/ BACKGROUND
WHITE ON BLUE (COLOR NO.
105090 IN FEDERAL STD. 5952)
DOUBLE COAT (TYP.)
CONCRETE
PAVING
RE:CIVIL
ROD AND SEALANT
OVER EXPANSION
FILLER
CONCRETE
PAVING
RE:CIVIL
SAND FILL
RE: CIVIL
87
9
8
SH
1
1
4
So
u
t
h
l
a
k
e
,
T
e
x
a
s
7
6
0
9
2
FI
R
S
T
N
A
T
I
O
N
A
L
B
A
N
K
ZA19-0011
TR
A
C
T
1
B
,
J
A
M
E
S
J
.
W
E
S
T
S
U
R
V
E
Y
,
A
B
S
T
R
A
C
T
N
O
.
1
6
2
0
,
SO
U
T
H
L
A
K
E
,
T
A
R
R
A
N
T
C
O
U
N
T
Y
,
T
E
X
A
S
ZONING CASE NO.SCALE:1/8" = 1'-0"01
550 WESTLAKE PARK BLVD., SUITE 300
HOUSTON, TEXAS 77079
713-465-4650
www.sligroup.com
ARCHITECTURE PLANNING INTERIOR DESIGN
COPYRIGHTC
C
The inf ormation, ideas, designs, details, layouts, techniques, f eatures, arrangements,
plans, se qu ences, dimens ions, al low ances , to ler ances , co nceptions , specif ications,
intentions, technolo gy or embodimen ts , as illustr ated, arranged, displ ayed, noted,
recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to
tangible form hereon, either expressly, inherently or by implication, are the conf idential
and proprietary inf ormation of SLI Design, Inc., and shall not be used f or any purpose
other than the specif ic project or undertaking identif ied on the drawing title block or
le gend f or w hich the y ar e a nd ha v e be en pre p a red by S LI D es ign , I nc. A ny o the r
repro duction, disclosu re o r use of any p or tion of the co nf ide ntial a nd pro pr ietar y
inf ormation of SLI Design, Inc., shall be a breach of the obligation of conf idence created
b y the a cc eptan ce of thi s d r a w in g f ro m S L I De si gn, In c. f or a spe c if i c pr o je c t o r
Contract. A ny copying, duplicating, reproducing, utilization, alteration, modif ication,
revision or change to this drawing, is expressly prohibited unless done with the prior
written consent or approval of SLI Design, Inc., and shall not be undertaken without
receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., f or
the limited purpose of complying with a specif ic Contract. The drawing remains the
property of SLI Design, Inc., and shall be returned upon request or completion of the
con t ra ct, un l e s s s pe c if i ca l l y a u t ho r iz ed b y Con t ra ct, un d er w hi c h it w as l o a n ed.
PR
O
J
E
C
T
N
U
M
B
E
R
:
ISSUED FOR CLIENT APPROVAL
ISSUED FOR BIDDING
ISSUED FOR PERMIT
ISSUED FOR CONSTRUCTION
DATE
MARK DESCRIPTION DATE
PRINT DATE
DRAWING TITLE
DRAWN BY
CHECKED BY
APPROVED BY
SHEET NO.
REVISIONS
DESIGN, INC.
ELEVATIONS
A-600
CM
TB
TB
STONE VENEERSTUCCO
FACADE
METAL SOFFIT
AND FASCIA
EAST
WEST
First NationalBank
First National Bank
NON-REFLECTIVE
SPANDREL
GLASS
NON-REFLECTIVE
GLASS
METAL SOFFIT
AND FASCIA
NON-REFLECTIVE
GLASS
NON-REFLECTIVE
SPANDREL
GLASS
STUCCO
FACADE
STONE VENEER
METAL SOFFIT
AND FASCIA
METAL SOFFIT
AND FASCIA
SCALE:1/8" = 1'-0"02 ELEVATION
ELEVATION
NOTE:
STUCCO TO MEET REQUIREMENTS OF
ZONING ORD.NO. 480, AS AMENDED,
SECTION 39 - OVERLAY ZONES.
STUCCO TO BE APPLIED USING 3-STEP
PROCESS OVER DIAMOND METAL MESH
TO A 7
8" THICKNESS OR BY OTHER
PROCESSES PRODUCING COMPARABLE
CEMENT STUCCO FINISH WITH EQUAL
OR GREATER STRENGTH AND
DURABILITY SPECIFICATIONS.
87
9
8
SH
1
1
4
So
u
t
h
l
a
k
e
,
T
e
x
a
s
7
6
0
9
2
FI
R
S
T
N
A
T
I
O
N
A
L
B
A
N
K
ZA19-0011
TR
A
C
T
1
B
,
J
A
M
E
S
J
.
W
E
S
T
S
U
R
V
E
Y
,
A
B
S
T
R
A
C
T
N
O
.
1
6
2
0
,
SO
U
T
H
L
A
K
E
,
T
A
R
R
A
N
T
C
O
U
N
T
Y
,
T
E
X
A
S
ZONING CASE NO.SCALE:1/8" = 1'-0"01
550 WESTLAKE PARK BLVD., SUITE 300
HOUSTON, TEXAS 77079
713-465-4650
www.sligroup.com
ARCHITECTURE PLANNING INTERIOR DESIGN
COPYRIGHTC
C
The inf ormation, ideas, designs, details, layouts, techniques, f eatures, arrangements,
plans, se qu ences, dimens ions, al low ances , to ler ances , co nceptions , specif ications,
intentions, technolo gy or embodimen ts , as illustr ated, arranged, displ ayed, noted,
recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to
tangible form hereon, either expressly, inherently or by implication, are the conf idential
and proprietary inf ormation of SLI Design, Inc., and shall not be used f or any purpose
other than the specif ic project or undertaking identif ied on the drawing title block or
le gend f or w hich the y ar e a nd ha v e be en pre p a red by S LI D es ign , I nc. A ny o the r
repro duction, disclosu re o r use of any p or tion of the co nf ide ntial a nd pro pr ietar y
inf ormation of SLI Design, Inc., shall be a breach of the obligation of conf idence created
b y the a cc eptan ce of thi s d r a w in g f ro m S L I De si gn, In c. f or a spe c if i c pr o je c t o r
Contract. A ny copying, duplicating, reproducing, utilization, alteration, modif ication,
revision or change to this drawing, is expressly prohibited unless done with the prior
written consent or approval of SLI Design, Inc., and shall not be undertaken without
receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., f or
the limited purpose of complying with a specif ic Contract. The drawing remains the
property of SLI Design, Inc., and shall be returned upon request or completion of the
con t ra ct, un l e s s s pe c if i ca l l y a u t ho r iz ed b y Con t ra ct, un d er w hi c h it w as l o a n ed.
PR
O
J
E
C
T
N
U
M
B
E
R
:
ISSUED FOR CLIENT APPROVAL
ISSUED FOR BIDDING
ISSUED FOR PERMIT
ISSUED FOR CONSTRUCTION
DATE
MARK DESCRIPTION DATE
PRINT DATE
DRAWING TITLE
DRAWN BY
CHECKED BY
APPROVED BY
SHEET NO.
REVISIONS
DESIGN, INC.
ELEVATIONS
A-6.10
CM
TB
TB
NORTH
SOUTH
METAL SOFFIT
AND FASCIA
NON-REFLECTIVE
GLASS
NON-REFLECTIVE
BULLET RESISTANT
GLASS
STUCCO
FACADESTONE VENEER NON-REFLECTIVE
SPANDREL
GLASS
METAL SOFFIT
AND FASCIA
STUCCO
FACADE STONE VENEERNON-REFLECTIVE
GLASS
NON-REFLECTIVE
SPANDREL
GLASS
SCALE:1/8" = 1'-0"02 ELEVATION
ELEVATION
NOTE:
STUCCO TO MEET REQUIREMENTS OF
ZONING ORD.NO. 480, AS AMENDED,
SECTION 39 - OVERLAY ZONES.
STUCCO TO BE APPLIED USING 3-STEP
PROCESS OVER DIAMOND METAL MESH
TO A 7
8" THICKNESS OR BY OTHER
PROCESSES PRODUCING COMPARABLE
CEMENT STUCCO FINISH WITH EQUAL
OR GREATER STRENGTH AND
DURABILITY SPECIFICATIONS.
T
T
T
STATE HIGHWAY 1
1
4
S
E
R
V
I
C
E
R
O
A
D
S
H
A
D
Y
O
A
K
S
D
R
I
V
E
EXISTING DRAINAGE PLAN
FIRST NATIONAL BANK
SOUTHLAKE, TEXAS
C I V I L E N G I N E E R I N G TBPE No. F-003116
DEOTTE, INC.D
O
I
N
o
.
2
0
1
8
1
1
2
.
0
0
420 Johnson Road, Suite 303 Keller, Texas 76248
817-337-8899 (Office) 817-337-5133 (Fax)
PREPARED FOR: FIRST NATIONAL BANK
1540 E. SOUTHLAKE BOULEVARD
SOUTHLAKE, TEXAS 76092
PHONE: (817) 305-0715
CONTACT: CINDY CAMPBELL
B
E
N
C
H
M
A
R
K
S
:
B
M
1
:
X
X
X
E
L
E
V
A
T
I
O
N
:
X
X
X
.
X
X
B
M
2
:
X
X
X
E
L
E
V
A
T
I
O
N
:
X
X
X
.
X
X
DOI No. 2018112.00 - IMPROVEMENTS FOR FIRST NATIONAL BANK - WATER, SEWER, STORM DRAIN AND PAVING - SOUTHLAKE, TEXAS
C
I
T
Y
C
A
S
E
N
O
.
Z
A
1
9
-
0
0
1
1
S
.
H
.
1
1
4
SHADY OAKS
D
O
V
E
N. WHITE CHAPEL
W
.
H
I
G
H
L
A
N
D
S
I
T
E
E
X
-
D
A
M
C-20.520.2 DRAINAGE AREA LABELQ100 (CFS)AREA (AC)DRAINAGE AREA DIVIDEEXISTING MAJOR CONTOUREXISTING MINOR CONTOURPROPOSED MAJOR CONTOURPROPOSED MINOR CONTOUR 600601FLOW DIRECTION EXISTING DRAINAGE AREAEXISTING FLOWPATHDESIGN POINTINLET DESIGNATION1 1. FINAL CALCULATIONS TO BE PROVIDED WITH FINAL ENGINEERING PLANS2. CRITERIA BASED ON CITY OF FORT WORTH ISWM CRITERIA MANUAL FORSITE DEVELOPMENT AND CONSTRUCTION. (LATEST EDITION)3. DOCUMENTATION AND SUPPORTING CALCULATIONS FOR DETENTIONASSESSMENT TO BE PROVIDED BY SEPARATE REPORT.4. FINAL ENGINEERING REVIEW AND COORDINATION MAY RESULT IN MINORADJUSTMENTS TO THIS PLANLEGEND
(
I
N
F
E
E
T
)
1
I
N
C
H
=
F
T
0
2
0
1
0
2
0
4
0
T
T
T
STATE HIGHWAY 1
1
4
S
E
R
V
I
C
E
R
O
A
D
S
H
A
D
Y
O
A
K
S
D
R
I
V
E
2
-
1
/
2
S
T
O
R
Y
B
U
I
L
D
I
N
G
F
O
O
T
P
R
I
N
T
=
6
,
2
4
3
S
F
B
U
I
L
D
I
N
G
=
1
6
,
0
0
0
S
F
F
F
E
=
6
1
6
.
0
0
6
1
5
6
1
5
615
612 613
6
1
4
6
1
6
6
1
7
6
1
8
6
1
9
6
1
5
614
6
1
6
615
612
6
1
3
6
1
4
6
1
4
6
1
4
61
5
611
6
1
6
6
1
7
6
1
8
G
R
A
T
E
I
N
L
E
T
2
'
C
U
R
B
O
P
E
N
I
N
G
2' CURBOPENING GRATEINLET
B
-
1
0
.
1
7
1
.
2
C
-
1
0
.
0
5
0
.
4
A-10.322.3 OS-10.180.5
O
S
-
2
0
.
3
0
0
.
8
6
1
6
B
-
2
0
.
7
2
5
.
2
B
-
3
0
.
2
9
2
.
1
B
-
4
0
.
4
7
3
.
4
PRELIMINARY GRADING &
DRAINAGE PLAN
FIRST NATIONAL BANK
SOUTHLAKE, TEXAS
C I V I L E N G I N E E R I N G TBPE No. F-003116
DEOTTE, INC.D
O
I
N
o
.
2
0
1
8
1
1
2
.
0
0
420 Johnson Road, Suite 303 Keller, Texas 76248
817-337-8899 (Office) 817-337-5133 (Fax)
PREPARED FOR: FIRST NATIONAL BANK
1540 E. SOUTHLAKE BOULEVARD
SOUTHLAKE, TEXAS 76092
PHONE: (817) 305-0715
CONTACT: CINDY CAMPBELL
B
E
N
C
H
M
A
R
K
S
:
B
M
1
:
X
X
X
E
L
E
V
A
T
I
O
N
:
X
X
X
.
X
X
B
M
2
:
X
X
X
E
L
E
V
A
T
I
O
N
:
X
X
X
.
X
X
DOI No. 2018112.00 - IMPROVEMENTS FOR FIRST NATIONAL BANK - WATER, SEWER, STORM DRAIN AND PAVING - SOUTHLAKE, TEXAS
C
I
T
Y
C
A
S
E
N
O
.
Z
A
1
9
-
0
0
1
1
S
.
H
.
1
1
4
SHADY OAKS
D
O
V
E
N. WHITE CHAPEL
W
.
H
I
G
H
L
A
N
D
S
I
T
E
C-20.520.2 DRAINAGE AREA LABELQ100 (CFS)AREA (AC)DRAINAGE AREA DIVIDEEXISTING MAJOR CONTOUREXISTING MINOR CONTOURPROPOSED MAJOR CONTOURPROPOSED MINOR CONTOUR 600601FLOW DIRECTION EXISTING DRAINAGE AREAEXISTING FLOWPATH
G
R
A
D
DESIGN POINTINLET DESIGNATION1 1. FINAL CALCULATIONS TO BE PROVIDED WITH FINAL ENGINEERING PLANS2. CRITERIA BASED ON CITY OF FORT WORTH ISWM CRITERIA MANUAL FORSITE DEVELOPMENT AND CONSTRUCTION. (LATEST EDITION)3. DOCUMENTATION AND SUPPORTING CALCULATIONS FOR DETENTIONASSESSMENT TO BE PROVIDED BY SEPARATE REPORT.4. FINAL ENGINEERING REVIEW AND COORDINATION MAY RESULT IN MINORADJUSTMENTS TO THIS PLANLEGEND
(
I
N
F
E
E
T
)
1
I
N
C
H
=
F
T
0
2
0
1
0
2
0
4
0
T
T
T
STATE HIGHWAY 1
1
4
S
E
R
V
I
C
E
R
O
A
D
S
H
A
D
Y
O
A
K
S
D
R
I
V
E
2
-
1
/
2
S
T
O
R
Y
B
U
I
L
D
I
N
G
F
O
O
T
P
R
I
N
T
=
6
,
2
4
3
S
F
B
U
I
L
D
I
N
G
=
1
6
,
0
0
0
S
F
F
F
E
=
6
1
6
.
0
0
I
N
S
T
A
L
L
:
6
"
F
I
R
E
S
E
R
V
I
C
E
6
"
G
A
T
E
V
A
L
V
E
I
N
S
T
A
L
L
:
F
D
C
E
X
F
H
I
N
S
T
A
L
L
:
F
I
R
E
H
Y
D
R
A
N
T
I
N
S
T
A
L
L
:
H
E
A
D
W
A
L
L
F
L
=
6
1
1
.
5
0
300' FHRADIUS (TYP)
1
5
'
W
A
T
E
R
E
A
S
E
M
E
N
T
I
N
S
T
A
L
L
:
2
'
x
3
'
G
R
A
T
E
I
N
L
E
T
T
O
P
=
6
1
4
.
5
0
F
L
=
6
1
2
.
5
0
6" SEWER SERVICE
6" FIRE SERVICE
DOMESTIC SERVICE
3
0
0
'
F
H
R
A
D
I
U
S
(
T
Y
P
)
I
N
S
T
A
L
L
:
1
"
S
E
R
V
I
C
E
T
O
M
E
T
E
R
1
"
W
A
T
E
R
M
E
T
E
R
(
D
O
M
.
)
2
"
S
E
R
V
I
C
E
T
O
B
U
I
L
D
I
N
G
I
N
S
T
A
L
L
:
1
"
W
A
T
E
R
M
E
T
E
R
(
I
R
R
.
)
1
2
"
P
R
I
V
A
T
E
S
T
O
R
M
D
R
A
I
N
12" PRIVATE
S
T
O
R
M
D
R
A
I
N
U
T
I
L
(
I
N
F
E
E
T
)
1
I
N
C
H
=
F
T
0
2
0
1
0
2
0
4
0
PRELIMINARY UTILITY PLAN
FIRST NATIONAL BANK
SOUTHLAKE, TEXAS
NOTES:1. ALL SEWER LINE SHALL BE SDR-35 PVC.2. ALL WATER PIPE SHALL BE SDR-18 C-900.3. ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE CITYOF SOUTHLAKE STANDARDS FOR PUBLIC WORKS CONSTRUCTION.4. ALL SEWER SERVICES ARE PRIVATE.5. ALL WATER SERVICES ARE PRIVATE FROM THE BUILDING TO THEMETER AND PUBLIC FROM THE METER TO THE WATER MAIN.6. ALL WATERLINE SHALL HAVE A MINIMUM 2' VERTICAL CLEARANCEFROM DRAINAGE STRUCTURES AND SEWER SERVICES.7. THE LOCATION OF EXISTING WATER AND SANITARY SEWERUTILITIES ARE APPROXIMATE. FINAL ENGINEERING REVIEW ANDCOORDINATION MAY RESULT IN SOME MINOR ADJUSTMENTS TOTHIS PLAN.8. ALL WATERLINE SHALL BE INSTALLED WITH A MINIMUM COVER OF42" UNLESS OTHERWISE NOTED OR EXPLICITLY APPROVED BY THECITY ENGINEER.9. FIRE HYDRANTS SHALL BE PLACED WITH STEAMER NOZZLE ATLEAST 3' BEHIND BACK OF CURB.10. PRIVATE SANITARY SEWER SERVICES NEED A PLUMBING PERMITAND MUST BE INSPECTED BY BUILDING INSPECTIONS PRIOR TOBURIAL.11. INSTALL BACKFLOW PROTECTION (DOUBLE CHECK VALVE) FORSPRINKLER SYSTEM ON RISER.LEGENDPROP. WATER SE
R
V
I
C
E
&
M
E
T
E
R
PROP. SEWER LIN
E
PROP. WATER PLU
G
EXIST. WATER MAI
N
PROP. FIRE HYDR
A
N
T
PROP. CULVERTEXIST. SEWER MAI
N
C I V I L E N G I N E E R I N G TBPE No. F-003116
DEOTTE, INC.D
O
I
N
o
.
2
0
1
8
1
1
2
.
0
0
420 Johnson Road, Suite 303 Keller, Texas 76248
817-337-8899 (Office) 817-337-5133 (Fax)
PREPARED FOR: FIRST NATIONAL BANK
1540 E. SOUTHLAKE BOULEVARD
SOUTHLAKE, TEXAS 76092
PHONE: (817) 305-0715
CONTACT: CINDY CAMPBELL
B
E
N
C
H
M
A
R
K
S
:
B
M
1
:
X
X
X
E
L
E
V
A
T
I
O
N
:
X
X
X
.
X
X
B
M
2
:
X
X
X
E
L
E
V
A
T
I
O
N
:
X
X
X
.
X
X
DOI No. 2018112.00 - IMPROVEMENTS FOR FIRST NATIONAL BANK - WATER, SEWER, STORM DRAIN AND PAVING - SOUTHLAKE, TEXAS
C
I
T
Y
C
A
S
E
N
O
.
Z
A
1
9
-
0
0
1
1
S
.
H
.
1
1
4
SHADY OAKS
D
O
V
E
N. WHITE CHAPEL
W
.
H
I
G
H
L
A
N
D
S
I
T
E
PROP. SEWER MA
N
H
O
L
E
8" WATER8" SEWERFIRE LANE, COMM
O
N
A
C
C
E
S
S
,
DRAINAGE & UTILI
T
Y
E
A
S
E
M
E
N
T
PROP. SEWER SE
R
V
I
C
E
PROP. WATER LIN
E