Loading...
Item 6 - Plans87 9 8 SH 1 1 4 So u t h l a k e , T e x a s 7 6 0 9 2 FI R S T N A T I O N A L B A N K ZA19-0011 NORTH SCALE:1" = 30'-0"01 SITE PLAN SH 11 4 F R O N T A G E R O A D SHADY O A K S D R I V E EXISTING PROPERTY LINE PROPOSED PROPERTY LINE N 01°03'23" E 790.47' S 8 7 ° 3 5 ' 2 1 " E 25 . 0 4 ' S 01°03'21" W 324.09' S 23° 3 3 ' 4 4 " E 2 2 2 . 5 6 ' N 8 8 ° 5 6 ' 0 1 " W 2 9 3 . 9 9 ' Arc - 3 0 5 . 1 6 ' Radius - 5 8 6 7 . 8 1 ' Delta - 2 ° 5 8 ' 4 7 " Chord - S 2 2 ° 0 4 ' 3 6 " E 3 0 5 . 1 3 ' N 7 4 ° 1 1 ' 1 9 " E 5 8 . 9 0 ' R.O.W . V A R I E S ( 3 0 0 ' - 0 " T O 5 0 0 ' - 0 " ) 60'-0" R. O . W . W . D O V E R O A D 8 8 ' - 0 " R . O . W . LOT E-1, BLOCK 1, OLD ORCHARD COUNTRY ESTATES CABINET A, SLIDE 7777, P.R.T.C.T. TRACT D BLOCK 1, OLD ORCHARD COUNTRY ESTATES VOLUME 388-118, PAGE 41, P.R.T.C.T. 11 4 P A L O M A H O L D I N G S , L L C ( R E M A I N D E R ) IN S T . N O . D 2 1 6 0 3 9 4 0 6 , D . R . T . C . T . TRACT C LOT E-2, BLOCK 1, OLD ORCHARD COUNTRY ESTATES CABINET A, SLIDE 7777, P.R.T.C.T. SF1-A SF-2 L.U.D. = FLOOD PLAIN L.U.D. = LOW DENSITY RESIDENTIAL BLOCK 1, OLD ORCHARD COUNTRY ESTATES VOLUME 388-118, PAGE 41, P.R.T.C.T. SF-2 L.U.D. = LOW DENSITY RESIDENTIAL AG L. U . D . = O F F I C E C O M M E R C I A L CURRENT OWNER: NEILL ROSEMMA NEILL KAY V GUNN 4812 BARKRIDGE TR FORT WORTH, TX 76109-3212 CU R R E N T O W N E R : 11 4 L A P A L O M A H O L D I N G S L L C C/ O M R M I K E M I L L S 12 0 7 S W H I T E C H A P E L B L V D S T E 1 5 0 SO U T H L A K E , T X 7 6 0 9 2 CURRENT OWNER: ROSS KENNETH R ROSS PAMELA POWELL 2050 SHADY OAKS DR SOUTHLAKE, TX 76092 CURRENT OWNER: JAMAL SYED JAMAL SADIA AMBARIN 2000 SHADY OAKS DR SOUTHLAKE, TX 76092 SF1-A L.U.D. = LOW DENSITY RESIDENTIAL CURRENT OWNER: KOPPALA SRINIVASULU POOSANAM SRIDEVI 1238 MINTO DR IRVING, TX 75063 EXISTING ASPHALT RESIDENTIAL DRIVEWAY EXISTING CONCRETE RESIDENTIAL DRIVEWAY 550 WESTLAKE PARK BLVD., SUITE 300 HOUSTON, TEXAS 77079 713-465-4650 www.sligroup.com ARCHITECTURE PLANNING INTERIOR DESIGN COPYRIGHTC C The inf ormation, ideas, designs, details, layouts, techniques, f eatures, arrangements, plans, sequences, dimensions, allowances, tolerances, conceptions, specif ications, intentions, technology or embodimen ts, as illustrated, arranged, displayed, noted, recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to tangible form hereon, either expressly, inherently or by implication, are the conf idential and proprietary inf ormation of SLI Design, Inc., and shall not be used f or any purpose other than the specif ic project or undertaking identif ied on the drawing title block or legend f or w hich they are and hav e been prep ared by SLI D esign , I nc . A ny other rep roduction, disclosure or use of any portion of the conf idential an d proprietary inf ormation of SLI Design, Inc., shall be a breach of the obligation of conf idence created by the ac c eptan ce of thi s d ra w ing f ro m S L I Desi gn, In c. f or a spec if i c projec t or Contract. Any copying, duplicating, reproducing, utilization, alteration, modif ication, revision or change to this drawing, is expressly prohibited unless done with the prior written consent or approval of SLI Design, Inc., and shall not be undertaken without receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., f or the limited purpose of complying with a specif ic Contract. The drawing remains the property of SLI Design, Inc., and shall be returned upon request or completion of the con t ract, un les s spec if i ca lly a ut hor iz ed by Con t ra ct, un d er w hi c h it w as loan ed. PR O J E C T N U M B E R : ISSUED FOR CLIENT APPROVAL ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION DATE MARK DESCRIPTION DATE PRINT DATE DRAWING TITLE DRAWN BY CHECKED BY APPROVED BY SHEET NO. REVISIONS DESIGN, INC. DIMENSIONED SITE PLAN SP-1.10 CM TB TB NORTH SPEED LIMIT 45 SPEED LIMIT 45 PROP O S E D A r c - 3 R a d i u D e l t C h 5 6 ' SCALE:1" = 30'-0"02 PROPOSED ENTRY SCALE:1" = 30'-0"03 PROPOSED ENTRY SCALE:NOT TO SCALE05VICINITY MAP PROP O S E D DESIGNATED LANDSCAPING AREA DESIGNATED FIRE LANE OVER 6" CONCRETE 4", 5", 6", OR 7" CONCRETE PAVEMENT SCALE:NOT TO SCALE04LEGEND AREA OF PROPERTY IN R.O.W. / 1 4 S P - 2 . 0 0 / 1 4 S P - 2 . 0 0 /14 SP-2.0 0 /14 SP-2.0 0 87 9 8 SH 1 1 4 So u t h l a k e , T e x a s 7 6 0 9 2 FI R S T N A T I O N A L B A N K ZA19-0011 550 WESTLAKE PARK BLVD., SUITE 300 HOUSTON, TEXAS 77079 713-465-4650 www.sligroup.com ARCHITECTURE PLANNING INTERIOR DESIGN COPYRIGHTC C The inf ormation, ideas, designs, details, layouts, techniques, f eatures, arrangements, plans, se qu ences, dimens ions, al low ances , to ler ances , co nceptions , specif ications, intentions, technolo gy or embodimen ts , as illustr ated, arranged, displ ayed, noted, recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to tangible form hereon, either expressly, inherently or by implication, are the conf idential and proprietary inf ormation of SLI Design, Inc., and shall not be used f or any purpose other than the specif ic project or undertaking identif ied on the drawing title block or le gend f or w hich the y ar e a nd ha v e be en pre p a red by S LI D es ign , I nc. A ny o the r repro duction, disclosu re o r use of any p or tion of the co nf ide ntial a nd pro pr ietar y inf ormation of SLI Design, Inc., shall be a breach of the obligation of conf idence created b y the a cc eptan ce of thi s d r a w in g f ro m S L I De si gn, In c. f or a spe c if i c pr o je c t o r Contract. A ny copying, duplicating, reproducing, utilization, alteration, modif ication, revision or change to this drawing, is expressly prohibited unless done with the prior written consent or approval of SLI Design, Inc., and shall not be undertaken without receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., f or the limited purpose of complying with a specif ic Contract. The drawing remains the property of SLI Design, Inc., and shall be returned upon request or completion of the con t ra ct, un l e s s s pe c if i ca l l y a u t ho r iz ed b y Con t ra ct, un d er w hi c h it w as l o a n ed. PR O J E C T N U M B E R : ISSUED FOR CLIENT APPROVAL ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION DATE MARK DESCRIPTION DATE PRINT DATE DRAWING TITLE DRAWN BY CHECKED BY APPROVED BY SHEET NO. REVISIONS DESIGN, INC. SITE ENLARGMENTS SP-2.00 CM TB TB 25 ACCESSIBLE PARKING STALL SIGN SCALE:NTS NOTE: BLUE PAINT (SEE NOTE) WHITE PAINT 3' - 6 " R=8 1/2" 3" 3'-6" 1 1/4" 7" 5 1 / 2 " 10 1 / 2 " 7" 6" 1'-6 1/4" 3" 1 1/4" 2"1/2" 3" 3" 2" 10 1 / 2 " 2' - 0 " KEY NOTES: PAINT WHITE QUIKRETE CONCRETE WHEEL STOP, 6FT OR EQUAL FIRE LANE AREAS SHALL BE PAINTED RED.RE: SP10 DENOTE FIRE LANE WITH RED STRIPE ON CURB AND WHITE "FIRE LANE- NO PARKING" STENCIL SPACED NO MORE THAN 25 FEET. 01 02 03 5"H. X 7 1/2"W. BUMPER PRECAST CONCRETE INTO PAVING 3/4" DOWELS EPOXY FILL HOLES W/ EPOXY SEE PLAN 23 WHEELSTOP SCALE:NTS SCALE:1/8"=1'-0"01 SITE ENLARGEMENT 01 01 03 02 SCALE:1/8"=1'-0"03 SITE ENLARGEMENT SCALE:1/8"=1'-0"04 KEYED NOTES 03 SCALE:1/8"=1'-0"05 SITE ENLARGEMENT SCALE:1/8"=1'-0"02 SITE ENLARGEMENT 01 03 03 SCALE:1/8"=1'-0"07 SITE ENLARGEMENT SCALE:NTS15 GRASS OR LANDSCAPE AREA 2" PVC SLEEVE AT LANDSCAPE AREAS, RE:SP-1.0 or L-1.0 2" SAND FILL BROOM FINISH COARSE TEXTURE ROD AND SEALANT OVER EXPANSION FILLER 6" CURB 2" PVC SLEEVE 6" CURB 2" PVC SLEEVE CONCRETE PAVING RE:CIVIL 2" PVC SLEEVE AT LANDSCAPE AREAS, RE:SP-1.0 or L-1.0 SCALE:NTS11CURB AT SIDEWALK SCALE:NTS12CURB AT GRADE CONCRETE CURB RAMP SLOPE NOT TO EXCEED 1:12 RAMP TO HAVE LIGHT REFLECTIVE VALUE AND TEXTURE TO SIGNIFICANTLY CONTRAST WITH ADJOINING PEDESTRIAN ROUTES. SCORED CONCRETE RAMP WITH GROOVES 1/4" DEEP, 3/4" WIDE AND 2" APART. SLOPE TO PREVENT ACCUMULATION OF WATER. CONCRETE SIDEWALK ACCESSIBLE PARKING SIGN SCALE:NTS13 CURBRAMP 17 ACCESSIBLE PARKING SIGN SCALE:NTS SLOTTED SQUARE TUBE 2,500 PSI CONCRETE INTERNATIONAL SYMBOL OF ACCESSIBILITY- BORDER & LETTERING IN WHITE ON BLUE BACKGROUND 12" X 18" - 16 GA. BONDERIZED STEEL SIGN (VERIFY SIZE & LETTERING W/ GOVERNING AUTHORITY) ADDITIONAL SIGN (12" X 6") REQUIRED FOR VAN PARKING SPACE - REF SITE PLAN 19 BOLLARD DETAILS SCALE:NTS #5 ROD @36" O.C. NEW 4"Ø GALVANIZED BOLLARD FILL WITH CONCRETE AND PAINT DARK BRONZE REINFORCED CONCRETE ISLAND RE: CIVIL #3 DOWELS @36" O.C. #5 ROD CONTINUOUS 1:12 1:12 1:12 1:12 21 MONUMENT SIGN SCALE:NTS EIFS CAP 3 4" STUCCO OVER CMU 8" REINFORCED CMU BLOCK RECESSED CAN LIGHT 2'-6" X 4'-0" LINTEL OR BOND BEAM REQUIRED FIRST NATIONAL BANK SCALE:NTS24 4" DIA. PAINTED PIPE BOLLARDS 4" DIA. PAINTED PIPE BOLLARDS 8" CMU BLOCK WITH STUCCO VENEER 3/4" STUCCO OVER METAL LATHE EIFS CAP RE:15/SP-2.00 3 4" STUCCO OVER FELT PAPER WITH METAL LATHE OVER TYVEK STUCCO WRAP 8" CMU EIFS CAP RE:15/SP-2.00 EIFS BAND RE:15/SP-2.00 EIFS BAND RE:15/SP-2.00 3/4" STUCCO OVER METAL LATHE EIFS CAP RE:15/SP-2.00 EIFS BAND RE:15/SP-2.00 R PANELS; RE:A-6.00 FOR COLOR 4"x4" PAINTED TUBE STEEL; HEAVY DUTY PIVOT HINGES 11 2"x 11 2" PAINTED TUBE STEEL; DUMPSTER ENCLOSURE PLANSECTIONEIFS BAND EIFS CAP FRONT ELEVATION TYPICAL SIDE ELEVATION BACK ELEVATION 03 03 TYP WALL OF BLDG EDGE OF CURB ROLL-UP CURB SCALE:NTS14 LIGHT POLE BASE 1" GROUT ANCHOR BOLTS UNPAINTED/CONCRETE LINE OF GRADE ANCHOR BOLTS PER MANUFACTURER'S SPECS 4 - #5'S VERTICAL REINFORCEMENT WITH #3 TIES AT 10" O.C. ROUND CONCRETE PIERS SYMBOL TO BE CENTERED ON WIDTH OF PARKING STALL - SYMBOLS ARE REQ'D TO CONTRAST W/ BACKGROUND WHITE ON BLUE (COLOR NO. 105090 IN FEDERAL STD. 5952) DOUBLE COAT (TYP.) CONCRETE PAVING RE:CIVIL ROD AND SEALANT OVER EXPANSION FILLER CONCRETE PAVING RE:CIVIL SAND FILL RE: CIVIL 87 9 8 SH 1 1 4 So u t h l a k e , T e x a s 7 6 0 9 2 FI R S T N A T I O N A L B A N K ZA19-0011SCALE:1/8" = 1'-0"01 550 WESTLAKE PARK BLVD., SUITE 300 HOUSTON, TEXAS 77079 713-465-4650 www.sligroup.com ARCHITECTURE PLANNING INTERIOR DESIGN COPYRIGHTC C The inf ormation, ideas, designs, details, layouts, techniques, f eatures, arrangements, plans, se qu ences, dimens ions, al low ances , to ler ances , co nceptions , specif ications, intentions, technolo gy or embodimen ts , as illustr ated, arranged, displ ayed, noted, recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to tangible form hereon, either expressly, inherently or by implication, are the conf idential and proprietary inf ormation of SLI Design, Inc., and shall not be used f or any purpose other than the specif ic project or undertaking identif ied on the drawing title block or le gend f or w hich the y ar e a nd ha v e be en pre p a red by S LI D es ign , I nc. A ny o the r repro duction, disclosu re o r use of any p or tion of the co nf ide ntial a nd pro pr ietar y inf ormation of SLI Design, Inc., shall be a breach of the obligation of conf idence created b y the a cc eptan ce of thi s d r a w in g f ro m S L I De si gn, In c. f or a spe c if i c pr o je c t o r Contract. A ny copying, duplicating, reproducing, utilization, alteration, modif ication, revision or change to this drawing, is expressly prohibited unless done with the prior written consent or approval of SLI Design, Inc., and shall not be undertaken without receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., f or the limited purpose of complying with a specif ic Contract. The drawing remains the property of SLI Design, Inc., and shall be returned upon request or completion of the con t ra ct, un l e s s s pe c if i ca l l y a u t ho r iz ed b y Con t ra ct, un d er w hi c h it w as l o a n ed. PR O J E C T N U M B E R : ISSUED FOR CLIENT APPROVAL ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION DATE MARK DESCRIPTION DATE PRINT DATE DRAWING TITLE DRAWN BY CHECKED BY APPROVED BY SHEET NO. REVISIONS DESIGN, INC. ELEVATIONS A-600 CM TB TB STONE VENEERSTUCCO FACADE METAL SOFFIT AND FASCIA EAST WEST First NationalBank First National Bank NON-REFLECTIVE SPANDREL GLASS NON-REFLECTIVE GLASS METAL SOFFIT AND FASCIA NON-REFLECTIVE GLASS NON-REFLECTIVE SPANDREL GLASS STUCCO FACADE STONE VENEER METAL SOFFIT AND FASCIA METAL SOFFIT AND FASCIA SCALE:1/8" = 1'-0"02 ELEVATION ELEVATION NOTE: STUCCO TO MEET REQUIREMENTS OF ZONING ORD.NO. 480, AS AMENDED, SECTION 39 - OVERLAY ZONES. STUCCO TO BE APPLIED USING 3-STEP PROCESS OVER DIAMOND METAL MESH TO A 7 8" THICKNESS OR BY OTHER PROCESSES PRODUCING COMPARABLE CEMENT STUCCO FINISH WITH EQUAL OR GREATER STRENGTH AND DURABILITY SPECIFICATIONS. 87 9 8 SH 1 1 4 So u t h l a k e , T e x a s 7 6 0 9 2 FI R S T N A T I O N A L B A N K ZA19-0011SCALE:1/8" = 1'-0"01 550 WESTLAKE PARK BLVD., SUITE 300 HOUSTON, TEXAS 77079 713-465-4650 www.sligroup.com ARCHITECTURE PLANNING INTERIOR DESIGN COPYRIGHTC C The inf ormation, ideas, designs, details, layouts, techniques, f eatures, arrangements, plans, se qu ences, dimens ions, al low ances , to ler ances , co nceptions , specif ications, intentions, technolo gy or embodimen ts , as illustr ated, arranged, displ ayed, noted, recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to tangible form hereon, either expressly, inherently or by implication, are the conf idential and proprietary inf ormation of SLI Design, Inc., and shall not be used f or any purpose other than the specif ic project or undertaking identif ied on the drawing title block or le gend f or w hich the y ar e a nd ha v e be en pre p a red by S LI D es ign , I nc. A ny o the r repro duction, disclosu re o r use of any p or tion of the co nf ide ntial a nd pro pr ietar y inf ormation of SLI Design, Inc., shall be a breach of the obligation of conf idence created b y the a cc eptan ce of thi s d r a w in g f ro m S L I De si gn, In c. f or a spe c if i c pr o je c t o r Contract. A ny copying, duplicating, reproducing, utilization, alteration, modif ication, revision or change to this drawing, is expressly prohibited unless done with the prior written consent or approval of SLI Design, Inc., and shall not be undertaken without receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., f or the limited purpose of complying with a specif ic Contract. The drawing remains the property of SLI Design, Inc., and shall be returned upon request or completion of the con t ra ct, un l e s s s pe c if i ca l l y a u t ho r iz ed b y Con t ra ct, un d er w hi c h it w as l o a n ed. PR O J E C T N U M B E R : ISSUED FOR CLIENT APPROVAL ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION DATE MARK DESCRIPTION DATE PRINT DATE DRAWING TITLE DRAWN BY CHECKED BY APPROVED BY SHEET NO. REVISIONS DESIGN, INC. ELEVATIONS A-6.10 CM TB TB NORTH SOUTH METAL SOFFIT AND FASCIA NON-REFLECTIVE GLASS NON-REFLECTIVE BULLET RESISTANT GLASS STUCCO FACADESTONE VENEER NON-REFLECTIVE SPANDREL GLASS METAL SOFFIT AND FASCIA STUCCO FACADE STONE VENEERNON-REFLECTIVE GLASS NON-REFLECTIVE SPANDREL GLASS SCALE:1/8" = 1'-0"02 ELEVATION ELEVATION NOTE: STUCCO TO MEET REQUIREMENTS OF ZONING ORD.NO. 480, AS AMENDED, SECTION 39 - OVERLAY ZONES. STUCCO TO BE APPLIED USING 3-STEP PROCESS OVER DIAMOND METAL MESH TO A 7 8" THICKNESS OR BY OTHER PROCESSES PRODUCING COMPARABLE CEMENT STUCCO FINISH WITH EQUAL OR GREATER STRENGTH AND DURABILITY SPECIFICATIONS. 2015 INTERNATIONAL BUILDING CODE CITY OF SOUTHLAKE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE CITY OF SOUTHLAKE AMENDMENTS 2015 INTERNATIONAL PLUMBING CODE CITY OF SOUTHLAKE AMENDMENTS 2015 INTERNATIONAL FIRE CODE AND NFPA WITH CITY OF SOUTHLAKE AMENDMENTS 2017 NATIONAL ELECTRIC CODE 2015 ENERGY CONSERVATION CODE BUILDING: OCCUPANCY TYPE:"B" TYPE OF CONSTRUCTION: "II-B" 100% SPRINKLERED BUILDING TOTAL SQUARE FOOTAGE: 16,000 SQ.FT. FIRST FLOOR: 6,243.03 SQ.FT. OFFICE:100 SQ.FT. PER OCCUPANT OCCUPANTS: (6,243 SQ.FT./100) = 62 EXITS REQUIRED:2 EXITS PROVIDED:2 SECOND FLOOR: 6,243.03 SQ. FT. OFFICE:100 SQ.FT. PER OCCUPANT OCCUPANTS: (6,243 SQ.FT./100) = 62 EXITS REQUIRED:2 EXITS PROVIDED:2 THIRD FLOOR: 3,513.94 SQ. FT. OFFICE:100 SQ.FT. PER OCCUPANT OCCUPANTS: (3,514 SQ.FT./100) = 35 EXITS REQUIRED:2 EXITS PROVIDED:2 OCCUPANT LOAD: 159 TOTAL ALL AREAS AND LEVELS TO BE MADE ACCESSIBLE PER LOCAL, STATE, AND FEDERAL CODES. FIRE ALARM PROVIDED 87 9 8 SH 1 1 4 So u t h l a k e , T e x a s 7 6 0 9 2 FI R S T N A T I O N A L B A N K ZA19-0011 550 WESTLAKE PARK BLVD., SUITE 300 HOUSTON, TEXAS 77079 713-465-4650 www.sligroup.com ARCHITECTURE PLANNING INTERIOR DESIGN COPYRIGHTC C The inf ormation, ideas, designs, details, layouts, techniques, f eatures, arrangements, plans, se qu ences, dimens ions, al low ances , to ler ances , co nceptions , specif ications, intentions, technolo gy or embodimen ts , as illustr ated, arranged, displ ayed, noted, recorded, indicated, represented, disclosed, evidenced, detailed or otherwise reduced to tangible form hereon, either expressly, inherently or by implication, are the conf idential and proprietary inf ormation of SLI Design, Inc., and shall not be used f or any purpose other than the specif ic project or undertaking identif ied on the drawing title block or le gend f or w hich the y ar e a nd ha v e be en pre p a red by S LI D es ign , I nc. A ny o the r repro duction, disclosu re o r use of any p or tion of the co nf ide ntial a nd pro pr ietar y inf ormation of SLI Design, Inc., shall be a breach of the obligation of conf idence created b y the a cc eptan ce of thi s d r a w in g f ro m S L I De si gn, In c. f or a spe c if i c pr o je c t o r Contract. A ny copying, duplicating, reproducing, utilization, alteration, modif ication, revision or change to this drawing, is expressly prohibited unless done with the prior written consent or approval of SLI Design, Inc., and shall not be undertaken without receipt of such prior written approval. This drawing is loaned by SLI Design, Inc., f or the limited purpose of complying with a specif ic Contract. The drawing remains the property of SLI Design, Inc., and shall be returned upon request or completion of the con t ra ct, un l e s s s pe c if i ca l l y a u t ho r iz ed b y Con t ra ct, un d er w hi c h it w as l o a n ed. PR O J E C T N U M B E R : ISSUED FOR CLIENT APPROVAL ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION DATE MARK DESCRIPTION DATE PRINT DATE DRAWING TITLE DRAWN BY CHECKED BY APPROVED BY SHEET NO. REVISIONS DESIGN, INC. TITLE BLOCK T-1.0 DF TB TB PROJECT LOCATION OWNER: FIRST NATIONAL BANK 1540 E. SOUTHLAKE BLVD. SOUTHLAKE, TX. 76092 ARCHITECT & BUILDER: THE SLI GROUP, INC. 15810 PARK TEN PLACE SUITE 300 HOUSTON, TEXAS 77049 P: (713) 465-4650 F: (713) 465-0077 CONVENIENCE OUTLETS 15" (FLOOR TO BOTTOM OF BOX UNLESS OTHERWISE NOTED ON PLAN) LIGHT SWITCHES 45" (FLOOR TO BOTTOM OF BOX) FIRE ALARM PULL STATIONS 48" (FLOOR TO BOTTOM OF PULL) TELEPHONE OUTLETS 15" (FLOOR TO BOTTOM OF BOX OR AS NOTED ON PLAN) WALL TELEPHONE OUTLETS 45" (FLOOR TO BOTTOM OF BOX) DATA CABLE OUTLETS 15" (FLOOR TO BOTTOM OF BOX) SMOKE AND HEAT DETECTORS CEILING MOUNTED CODE INFORMATION TITLE SHEET T-1.0 TITLE SHEET AND CODE INFORMATION CIVIL C-1 COVER SHEET C-2 GENERAL NOTES C-3 OVERALL SITE PLAN C-4 DEMOLITION PLAN C-5 GRADING AND DRAINAGE PLAN C-6 PAVING PLAN C-7 SITE UTILITY PLAN C-8 SWPPP PLAN C-9 SWPPP DETAILS C-10 MISCELLANEOUS DETAILS ARCHITECTURAL SITE SP-1.0 SITE PLAN ARCHITECTURAL A-0.0 ACCESSIBILITY ROUTE COMPLIANCE A-0.1 ACCESSIBILITY ELEMENT COMPLIANCE A-1.0 FIRST FLOOR PLAN A-1.1 SECOND FLOOR PLAN A-1.2 THIRD FLOOR PLAN A-1.3 RESTROOM LAYOUT A-1.4 PLAN DETAILS A-1.5 PLAN DETAILS A-2.0 DOOR AND WINDOW SCHEDULE A-2.1 DOOR AND WINDOW SCHEDULE A-2.2 DOOR AND WINDOW SCHEDULE A-3.0 INTERIOR PARTITIONS A-4.0 FIRST FLOOR RCP A-4.1 SECOND FLOOR RCP A-4.2 THIRD FLOOR RCP A-5.0 ROOF PLAN A-6.0 EXTERIOR ELEVATIONS A-6.1 EXTERIOR ELEVATIONS A-7.0 BUILDING SECTIONS A-8.0 WALL SECTIONS A-8.1 WALL SECTIONS A-9.0 STAIR DETAILS A-9.1 STAIR DETAILS A-9.2 STAIR DETAILS A-9.3 STAIR DETAILS A-9.4 ELEVATOR DETAILS A-9.5 WATERPROOFING PLAN A-9.6 WATERPROOFING DETAILS A-10.0 INTERIOR ELEVATIONS A-10.1 INTERIOR ELEVATIONS A-10.2 INTERIOR ELEVATIONS A-11.0 MILLWORK DETAILS A-11.1 MILLWORK DETAILS A-11.2 MILLWORK DETAILS A-12.0 FIRST FLOOR INTERIOR FINISH PLAN A-12.1 SECOND FLOOR INTERIOR FINISH PLAN A-12.2 THIRD FLOOR INTERIOR FINISH PLAN A-13.0 FIRST FLOOR ELECTRICAL PLAN A-13.1 SECOND FLOOR ELECTRICAL PLAN A-13.2 THIRD FLOOR ELECTRICAL PLAN STRUCTURAL S0.0 GENERAL NOTES S0.1 GENERAL NOTES S1.1 FOUNDATION PLAN S2.1 SECOND FLOOR FRAMING PLAN S2.2 THIRD FLOOR FRAMING PLAN S3.1 ROOF FRAMING PLAN S4.1 FOUNDATION DETAILS S4.2 FOUNDATION DETAILS S5.1 FLOOR FRAMING DETAILS S5.2 FLOOR FRAMING DETAILS S6.1 ROOF FRAMING DETAILS S6.2 FRAMING DETAILS S7.1 X-BRACING DETAILS S7.2 TRUSS PROFILE AND DETAILS MECHANICAL, ELECTRICAL, AND PLUMBING M1.01 MECHANICAL PLAN - LEVEL 1 M1.02 MECHANICAL PLAN - LEVEL 2 M1.03 MECHANICAL PLAN - LEVEL 3 M3.01 MECHANICAL DETAILS M3.02 MECHANICAL DETAILS M3.03 MECHANICAL CONTROLS DETAILS M3.04 MECHANICAL DETAILS E1.00 ELECTRICAL SITE PLAN EL1.01 ELECTRICAL LIGHTING PLAN - LEVEL 1 EL1.02 ELECTRICAL LIGHTING PLAN - LEVEL 2 EL1.03 ELECTRICAL LIGHTING PLAN - LEVEL 3 EP1.01 ELECTRICAL POWER PLAN - LEVEL 1 EP1.02 ELECTRICAL POWER PLAN - LEVEL 2 EP1.03 ELECTRICAL POWER PLAN - LEVEL 3 E3.01 ELECTRICAL DETAILS E3.02 ELECTRICAL DETAILS E3.03 ELECTRICAL PANEL SCHEDULES E3.04 ELECTRICAL PANEL SCHEDULES E3.05 ELECTRICAL PANEL SCHEDULES E3.06 ELECTRICAL PANEL SCHEDULES E3.07 ELECTRICAL PANEL SCHEDULES P1.00 PLUMBING PLAN - UNDER SLAB P1.01 PLUMBING PLAN - LEVEL 1 P1.02 PLUMBING PLAN - LEVEL 2 P1.03 PLUMBING PLAN - LEVEL 3 P1.04 PLUMBING PLAN - ROOF P3.01 PLUMBING SCHEDULES P3.02 PLUMBING DETAILS P3.03 PLUMBING RISER P3.04 PLUMBING RISER P3.05 PLUMBING RISER FA1.01 FIRE ALARM PLAN - LEVEL 1 FA1.02 FIRE ALARM PLAN - LEVEL 2 FA1.03 FIRE ALARM PLAN - LEVEL 3 FP1.01 FIRE PROTECTION PLAN - LEVEL 1 FP1.02 FIRE PROTECTION PLAN - LEVEL 2 FP1.03 FIRE PROTECTION PLAN - LEVEL 3 FP3.01 FIRE PROTECTION DETAILS CIVIL: DEOTTE, INC. 420 JOHNSON ROAD SUITE 303 KELLER, TEXAS 76248 (817) 337-8899 STRUCTURAL: MEP: LANDSCAPE ARCHITECT: SAGE GROUP, INC. 1130 N. CARROLL AVENUE, SUITE 200 SOUTHLAKE, TEXAS 76092 (817) 424-2626 TDLR FILE NUMBER EAB PROJECT NUMBER EABPRJ CONTACT INFORMATION: DRAWING INDEX RENDERING - NOT TO SCALEAREA MAP - NOT TO SCALE TYPICAL MOUNTING HEIGHTS GENERAL NOTES 1. NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR OMISSIONS. 2. ALL WORK SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL ORDINANCES. 3. ALL DIMENSIONS ARE TO FINISHED FACE OF PARTITIONS. 4. ALL DOORS ON AN ACCESSIBLE ROUTE SHALL HAVE A MIN. 18" CLEAR ON THE PULL SIDE, A MIN. 12" CLEAR ON THE PUSH SIDE WHEN DOOR IS EQUIPPED WITH BOTH A LATCH AND CLOSER. 5. ALL DOORS TO RECEIVE NEW AMERICAN DISABILITIES ACT COMPLIANT HARDWARE. 6. IN ALL FIRE RATED ASSEMBLIES ALL PENETRATIONS SHALL BE SEALED. ALL FIREWALLS SHALL HAVE SIGNS OR STENCILING PERMANENTLY INSTALLED ABOVE ANY DECORATIVE CEILING AND/OR IN CONCEALED SPACES. THE LETTERING SHALL BE 2" IN HEIGHT AND SPACED EVERY 12'. THE FOLLOWING WORDING IS REQUIRED "(X) HOUR FIRE AND SMOKE WALL - PROTECT ALL PENETRATIONS" ELECTRICAL SECTION ELEVATION SYMBOLS DESCRIPTION NORTH ARROW ENLARGED DETAIL REFERENCE BUILDING SECTION WALL SECTION SECTION DETAIL ELEVATION DIMENSION LINES MATCH LINE REVISION NUMBER & AFFECTED AREA VERTICAL ELEVATION PARTITION TYPE WINDOW TYPE DOOR/HARDWARE IDENTIFICATION ROOM NUMBER/ EQUIPMENT TYPE SUSPENDED ACOUSTIC. CEILING GRID FLUORESCENT LIGHT FIXTURE INCANDESCENT LIGHT FIXTURE S/A DIFFUSER R/A GRILLE EXIT SIGN (WITH ARROW) FIRE ALARM HORN SMOKE DETECTOR IONIZATION DETECTOR SPEAKER SPRINKLER HEADS CEILING GRID START POINT NORTH A4.0 A4.0 2 A4.0 5 A3 2A 3 . 1 02/A3.0 2'-0"3' - 0 " 3 F3 2 4 5 21 325 2 H S I S CONCRETE PRECAST CONCRETE CMU CONCRETE (1/8" SCALE) CAST/CUT STONE NATURAL STONE STEEL ALUMINUM BRASS/BRONSE FINISHED WOOD METAL LATH & PLASTER CERAMIC/QUARRY TILE GLASS/MIRROR GRADE/EARTH GRAVEL SAND CONT. WOOD BLOCKING DISCONT. WOOD SHIM. PLYWOOD SPRAYED FIREPROOFING BATT/BLANKET INSULATION RIGID INSULATION BATT/BLANKET INSULATION GYPSUM SHEATHING GYPSUM WALLBOARD BACKER ROD & SEALANT JOINT FILLER ACCOST. CEILING PLASTIC LAMINATE CARPET SH 114 Southlake, Texas 76092 FIRST NATIONAL BANK TRACT 1B, JAMES J. WEST SURVEY, ABSTRACT NO. 1620, SOUTHLAKE, TARRANT COUNTY, TEXAS T T T STATE HIGHWAY 1 1 4 S E R V I C E R O A D S H A D Y O A K S D R I V E EXISTING DRAINAGE PLAN FIRST NATIONAL BANK SOUTHLAKE, TEXAS C I V I L E N G I N E E R I N G TBPE No. F-003116 DEOTTE, INC.D O I N o . 2 0 1 8 1 1 2 . 0 0 420 Johnson Road, Suite 303 Keller, Texas 76248 817-337-8899 (Office) 817-337-5133 (Fax) PREPARED FOR:FIRST NATIONAL BANK 1540 E. SOUTHLAKE BOULEVARD SOUTHLAKE, TEXAS 76092 PHONE: (817) 305-0715 CONTACT: CINDY CAMPBELL B E N C H M A R K S : B M 1 : X X X E L E V A T I O N : X X X . X X B M 2 : X X X E L E V A T I O N : X X X . X X DOI No. 2018112.00 - IMPROVEMENTS FOR FIRST NATIONAL BANK - WATER, SEWER, STORM DRAIN AND PAVING - SOUTHLAKE, TEXAS C I T Y C A S E N O . Z A 1 9 - 0 0 1 1 S . H . 1 1 4 SHADY OAKS D O V E N. WHITE CHAPEL W . H I G H L A N D S I T E E X - D A M C-20.520.2 DRAINAGE AREA LABELQ100 (CFS)AREA (AC)DRAINAGE AREA DIVIDEEXISTING MAJOR CONTOUREXISTING MINOR CONTOURPROPOSED MAJOR CONTOURPROPOSED MINOR CONTOUR 600601FLOW DIRECTION EXISTING DRAINAGE AREAEXISTING FLOWPATHDESIGN POINTINLET DESIGNATION1 1.FINAL CALCULATIONS TO BE PROVIDED WITH FINAL ENGINEERING PLANS2.CRITERIA BASED ON CITY OF FORT WORTH ISWM CRITERIA MANUAL FORSITE DEVELOPMENT AND CONSTRUCTION. (LATEST EDITION)3.DOCUMENTATION AND SUPPORTING CALCULATIONS FOR DETENTIONASSESSMENT TO BE PROVIDED BY SEPARATE REPORT.4.FINAL ENGINEERING REVIEW AND COORDINATION MAY RESULT IN MINORADJUSTMENTS TO THIS PLANLEGEND ( I N F E E T ) 1 I N C H = F T 0 2 0 1 0 2 0 4 0 T T T STATE HIGHWAY 1 1 4 S E R V I C E R O A D S H A D Y O A K S D R I V E 2 - 1 / 2 S T O R Y B U I L D I N G F O O T P R I N T = 6 , 2 4 3 S F B U I L D I N G = 1 6 , 0 0 0 S F F F E = 6 1 4 . 5 0 6 1 5 613 6 1 3 613 6 1 4 6 1 6 6 1 7 6 1 8 6 1 9 6 1 5 6 1 2 6 1 3 6 1 4 6 1 6 6 1 7 6 1 5 614 6 1 3 6 1 3 6 1 4 6 1 2 6 1 3 611612 6 1 5 6 1 6 6 1 7 6 1 5 6 1 6 A - 4 0 . 3 0 2 . 2 G R A T E I N L E T G R A T E I N L E T L A N D S C A P E I N L E T 2 ' C U R B O P E N I N G 2 ' C U R B O P E N I N G GRATEINLET S W A L E S W A L E A - 5 0 . 0 6 0 . 4 A - 6 0 . 0 6 0 . 4 A - 3 0 . 4 6 3 . 3 A-20.251.8 B - 1 0 . 1 3 0 . 9 B - 2 0 . 2 9 2 . 1 B - 3 0 . 3 2 2 . 3 C - 1 0 . 0 6 0 . 4 A-10.110.8 OS-10.180.4 O S - 2 0 . 3 0 0 . 8 G R A T E I N L E T 6 1 5 6 1 4 6 1 4 6 1 6 PRELIMINARY GRADING & DRAINAGE PLAN FIRST NATIONAL BANK SOUTHLAKE, TEXAS C I V I L E N G I N E E R I N G TBPE No. F-003116 DEOTTE, INC.D O I N o . 2 0 1 8 1 1 2 . 0 0 420 Johnson Road, Suite 303 Keller, Texas 76248 817-337-8899 (Office) 817-337-5133 (Fax) PREPARED FOR:FIRST NATIONAL BANK 1540 E. SOUTHLAKE BOULEVARD SOUTHLAKE, TEXAS 76092 PHONE: (817) 305-0715 CONTACT: CINDY CAMPBELL B E N C H M A R K S : B M 1 : X X X E L E V A T I O N : X X X . X X B M 2 : X X X E L E V A T I O N : X X X . X X DOI No. 2018112.00 - IMPROVEMENTS FOR FIRST NATIONAL BANK - WATER, SEWER, STORM DRAIN AND PAVING - SOUTHLAKE, TEXAS C I T Y C A S E N O . Z A 1 9 - 0 0 1 1 S . H . 1 1 4 SHADY OAKS D O V E N. WHITE CHAPEL W . H I G H L A N D S I T E C-20.520.2 DRAINAGE AREA LABELQ100 (CFS)AREA (AC)DRAINAGE AREA DIVIDEEXISTING MAJOR CONTOUREXISTING MINOR CONTOURPROPOSED MAJOR CONTOURPROPOSED MINOR CONTOUR 600601FLOW DIRECTION EXISTING DRAINAGE AREAEXISTING FLOWPATH G R A D DESIGN POINTINLET DESIGNATION1 1.FINAL CALCULATIONS TO BE PROVIDED WITH FINAL ENGINEERING PLANS2.CRITERIA BASED ON CITY OF FORT WORTH ISWM CRITERIA MANUAL FORSITE DEVELOPMENT AND CONSTRUCTION. (LATEST EDITION)3.DOCUMENTATION AND SUPPORTING CALCULATIONS FOR DETENTIONASSESSMENT TO BE PROVIDED BY SEPARATE REPORT.4.FINAL ENGINEERING REVIEW AND COORDINATION MAY RESULT IN MINORADJUSTMENTS TO THIS PLANLEGEND ( I N F E E T ) 1 I N C H = F T 0 2 0 1 0 2 0 4 0 T T T STATE HIGHWAY 1 1 4 S E R V I C E R O A D S H A D Y O A K S D R I V E 2 - 1 / 2 S T O R Y B U I L D I N G F O O T P R I N T = 6 , 2 4 3 S F B U I L D I N G = 1 6 , 0 0 0 S F F F E = 6 1 4 . 5 0 I N S T A L L : 6 " F I R E S E R V I C E 6 " G A T E V A L V E I N S T A L L : F D C E X F H I N S T A L L : F I R E H Y D R A N T INSTALL:HEADWALLFL = 609.00 300' FHRADIUS (TYP) 1 5 ' W A T E R E A S E M E N T I N S T A L L : 3 ' x 3 ' G R A T E I N L E T T O P = 6 1 2 . 4 0 F L = 6 0 9 . 0 0 I N S T A L L : 3 ' x 3 ' G R A T E I N L E T T O P = 6 1 3 . 2 0 F L = 6 0 9 . 8 0 I N S T A L L : 3 ' x 3 ' G R A T E I N L E T T O P = 6 1 3 . 5 5 F L = 6 1 0 . 2 0 I N S T A L L : L A N D S C A P E A R E A D R A I N T O P = 6 1 4 . 0 5 F L = 6 1 0 . 7 5 REMOVE:EX HEADWALLINSTALL:3'x3' GRATE INLETTOP = 612.00FL = 607.88 6" SEWER SERVICE 6" FIRE SERVICE DOMESTIC SERVICE 3 0 0 ' F H R A D I U S ( T Y P ) 24" STORM DRAI N 2 4 " S T O R M D R A I N I N S T A L L : 1 " S E R V I C E T O M E T E R 1 " W A T E R M E T E R ( D O M . ) 2 " S E R V I C E T O B U I L D I N G I N S T A L L : 1 " W A T E R M E T E R ( I R R . ) U T I L ( I N F E E T ) 1 I N C H = F T 0 2 0 1 0 2 0 4 0 PRELIMINARY UTILITY PLAN FIRST NATIONAL BANK SOUTHLAKE, TEXAS NOTES:1.ALL SEWER LINE SHALL BE SDR-35 PVC.2.ALL WATER PIPE SHALL BE SDR-18 C-900.3.ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE CITYOF SOUTHLAKE STANDARDS FOR PUBLIC WORKS CONSTRUCTION.4.ALL SEWER SERVICES ARE PRIVATE.5.ALL WATER SERVICES ARE PRIVATE FROM THE BUILDING TO THEMETER AND PUBLIC FROM THE METER TO THE WATER MAIN.6.ALL WATERLINE SHALL HAVE A MINIMUM 2' VERTICAL CLEARANCEFROM DRAINAGE STRUCTURES AND SEWER SERVICES.7.THE LOCATION OF EXISTING WATER AND SANITARY SEWERUTILITIES ARE APPROXIMATE. FINAL ENGINEERING REVIEW ANDCOORDINATION MAY RESULT IN SOME MINOR ADJUSTMENTS TOTHIS PLAN.8.ALL WATERLINE SHALL BE INSTALLED WITH A MINIMUM COVER OF42" UNLESS OTHERWISE NOTED OR EXPLICITLY APPROVED BY THECITY ENGINEER.9.FIRE HYDRANTS SHALL BE PLACED WITH STEAMER NOZZLE ATLEAST 3' BEHIND BACK OF CURB.10.PRIVATE SANITARY SEWER SERVICES NEED A PLUMBING PERMITAND MUST BE INSPECTED BY BUILDING INSPECTIONS PRIOR TOBURIAL.11.INSTALL BACKFLOW PROTECTION (DOUBLE CHECK VALVE) FORSPRINKLER SYSTEM ON RISER.LEGENDPROP. WATER SE R V I C E & M E T E R PROP. SEWER LIN E PROP. WATER PLU G EXIST. WATER MAI N PROP. FIRE HYDR A N T PROP. CULVERTEXIST. SEWER MAI N C I V I L E N G I N E E R I N G TBPE No. F-003116 DEOTTE, INC.D O I N o . 2 0 1 8 1 1 2 . 0 0 420 Johnson Road, Suite 303 Keller, Texas 76248 817-337-8899 (Office) 817-337-5133 (Fax) PREPARED FOR:FIRST NATIONAL BANK 1540 E. SOUTHLAKE BOULEVARD SOUTHLAKE, TEXAS 76092 PHONE: (817) 305-0715 CONTACT: CINDY CAMPBELL B E N C H M A R K S : B M 1 : X X X E L E V A T I O N : X X X . X X B M 2 : X X X E L E V A T I O N : X X X . X X DOI No. 2018112.00 - IMPROVEMENTS FOR FIRST NATIONAL BANK - WATER, SEWER, STORM DRAIN AND PAVING - SOUTHLAKE, TEXAS C I T Y C A S E N O . Z A 1 9 - 0 0 1 1 S . H . 1 1 4 SHADY OAKS D O V E N. WHITE CHAPEL W . H I G H L A N D S I T E PROP. SEWER MA N H O L E 8" WATER8" SEWERFIRE LANE, COMM O N A C C E S S , DRAINAGE & UTILI T Y E A S E M E N T PROP. SEWER SE R V I C E PROP. WATER LIN E