Loading...
Item 7 - Plansexcavation: macs piers: long and long structure: texas shotcrete steel / plumbing: colunga deck sq ft: 120 concrete lounge pad perimeter ft: 140' sanitizer components: salt general pool specifications general spa specifications ***materials specifications***all subcontractors should refer to the customer selection sheet for material specifications equipment specifications water feature specifications steel/plumbing specifications subcontractor roster area: 1000 sq. ft size: 20' X 50' loveseats/benches/swimouts: 2tanning deck/beach entry: dimensions: 7'6" X 7'6" jets: 12 (6) Twirly Birds and (6) Regular spa surface area: 56.25 sq. ft.height: 0 fountain: includedspillway type: tile spillway beam type: standard filter: 520 sq. ft. cartridgemain pump: pentair intelliflo Spa pump: 1.5 HP Whisperflo for extra 6 jets pool cleaner: polaris 280 black maxclock/computer: pentair easy touch 8 with screenlogic heater: pentair 400K BTU mastertemp nat. gaspool lights: (6) pentair glo brites spa lights: (2) pentair glo brites water feature type 1: spa fountain water feature type 2: water feature type 3: steel size: 1/2 steel centers: 10" pool capacity: gas line: included to heater skimmers: 2 pool returns: 6 overflow: included drain type: dual, vgb approved equipment pad: included bypass return: fill line type: to house water with double check reroute: gas sewer electric none scale: A CUSTOM OUTDOOR LIVING DESIGN FOR: home owner: cummingsaddress: 2500 raintree city: southlake phone: 646-319-3383 dig tess confirmation : 1/8"=1'0" depth: 3'6" - 5'6" - 4'6" e-mail: lpcummings@cummingselec.com LOT/BLOCK/SUB: tile and coping: servellon pool deck: infinity gas: kel-tex electric: ar electric sprinkler: n/a interior surface: plaster pros clean and grade: pando or kel-tex shell type: SHOTCRETEsoil stabilization pool/deck/both: TBD 24" X 36" X 2" Coping 42 " L y n x G r i l l 24 " X 1 8 " X 1 4 " ba r s i n k 42" tall 4' X 8' seating bar with storage underneath 13'6" X 16' cedar pergola 4" X 12" Beams 2" X 6" joists 8" X 8" Posts perimeter and cross beams 6 mechanically drilled piers (1) of (5) cedar doors 10' x 12" CONCRETE LOUNGE PAD 20' 0" 3'6" 5'6" 4'6" (1) of (2) Brass umbrella sleeve 3' 6" 41' 6" (1) of (2) Brass Volleyball Sleeves customer to determine final location prior to concrete pour step into spa split level bench 3" down this side of bench EXISTING COVERED PATIO TO BE CAPPED BY OTHERS CE N T E R L I N E CE N T E R L I N E S S S 13' 0" 17' 0" R R R R R R R R D D r a i n a g e D D r a i n a g e D D r a i n a g e D D r a i n a g e J J J J J J J J J J Jets in red on seperate booster J J note: see pool equipment location on site plan 9117 belshire dr #100, NRH, TX 76182 (817) 431-8897 www.watercrestpools.com 50' 0" C note: fill line in skimmer tied to existing water line with back flow preventer wall suction for additional 6 jets see ac c e s s plan pr o v i ded in con s t ruction docs for ac c e s s detai l note: structure on a seperate permit access -- large tractor �=====-I ------1-- I I II I I I I I I I I I 0 : II Ii I I I I I I I B]I I �--- l --------- .,..13'-6"l 7 , Project Drawing Trtle Olivia Lilley, ARCHITECT 14C Ranch 1630 Shepard Rd. Aubrey, Texas 76227 917.488.7250 www.lilleyarchitect.com CUMMINGS RESIDENCE 2500 RAINTREE DRIVE SOUTHLAKE, TEXAS 76092 OUTDOOR GRILL FLOOR PLAN 0 L I V I A L I L L E Y I Project No. ARCHITECT 1722 Drawn By OLL Date I Scale I Floor I Drawing No. 01.22.19 I 1/4"=1'-o" I 1 I SK-A