Loading...
Item 13 - PresentationZoning Change and Site Plan Carroll ISD Senior High School Music Building Item 13 ZA18-0058 ZA18-0058 Owner: Carroll Independent School District Applicant: Huckabee Associates, Inc. Request: Approval of a Zoning Change and Site Plan from “S-P-1” Detailed Site Plan District to “S-P-1” Detailed Site Plan District to allow improvements to the CISD Senior High School to include an approximately 60,000 square foot music building addition and associated site improvements Location: 1501 W. Southlake Blvd. Aerial View View East Overall Site Plan Enlarged Site Plan 150’ stacking required ±27’ provided (variance requested) Access control gates Music Building (Proposed) Art Building (Existing) “S-P-1” Regulations The “S-P-1” regulations below are proposed for the new improvements only. No other changes to the previously approved “S-P-1” zoning regulations or conditions of approval are proposed. Regulation “CS” Community Service District (Base “S-P-1” zoning) S-P-1 Regulation Articulation and Masonry Façade Materials This site is subject to the Residential Adjacency and Corridor Overlay District regulations, which includes specific requirements for masonry façade materials and vertical and horizontal articulation on buildings within 400’ of residential property and on all facades visible from FM 1709 and S. Peytonville Ave. Allow non-masonry façade materials and horizontal and vertical articulation as shown on the site plan and building elevations. Maximum Impervious Coverage 65% 73% Bufferyards New construction that increases the building square footage by 30% or that exceeds 5,000 square feet requires bufferyards to meet current requirements for the entire site. Existing bufferyards are to remain as they exist. Perspective Views North Elevation West Elevation West Elevation 2 South Elevation East Elevation Proposed Traffic Flow Landscape Plan Tree Conservation Plan Variance Requests 1.Masonry Ordinance No. 557, as amended, requires all buildings to have exterior walls constructed using a masonry material covering at least eighty percent (80%) of said walls, exclusive of all windows, doors, roofs, glass construction materials, or sidewalk and walkway covers. The applicant is requesting a variance to allow composite and metal panels as shown on the elevations. 2.Driveway Ordinance No. 634, as amended, Section 5.2.d requires a minimum stacking depth of 150’. The applicant is requesting a stacking depth of approximately 27’ on the northern S. Peytonville Ave. driveway. 3.Landscape Ordinance 544-B requires interior landscaping to comply with the current ordinances for new construction greater in size than 30% of the existing building or greater than 5,000 square feet. The applicant is requesting a variance to the Landscape Ordinance to request relief from the interior landscaping requirements to allow the landscaping as shown on the plan. Questions?