Loading...
Item 8 - PlansMAIN LOAD CENTER & UTILITY METER VISIBLE, LOCKABLE, LABELED AC DISCONNECT AC COMBINER BATTERIES FLORENCE RD PROJECT NAME: DRAWN DATE: DRAWN BY: ARCHITECT/FIELD DRAWING INFORMATION PLAN ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. DRAWING NOTES: PHOTOVOLTAIC SOLAR MODULE MFG/MODEL: MODULE RATED AT: MULTIPLY BY QTY. OF MODULES: ARRAY SYSTEM SIZE: SYSTEM AZIMUTH: MOUNTING HEIGHT: ROOF PITCH: P: 469-209-5910 RESIDENCE JURISDICTION: ƒ -STORY :12 3165 FLORENCE RD SOUTHLAKE, TX 76262 CITY OF SOUTHLAKE 330 W 36 11.880 kW 180 1,12 1 TK 08/27/18 REV DESCRIPTION DATE GOOD FAITH ENERGY PV-1PLOT PLAN SCALE: 1"=30'-0"1 SHEET INDEX PLOT PLAN SOLAR LAYOUT ATTACHMENT DETAILS ELECTRICAL LINE DIAGRAM NOTES: - SYSTEM FOLLOWS ANY/ALL FIRE CODE SETBACKS PER ORDINANCES OF THE CITY OF SOUTHLAKE. - ALL PROJECTS WILL COMPLY WITH THE ORDINANCES OF THE CITY OF SOUTHLAKE. - PRODUCT DATA SHEETS WILL BE INCLUDED. - ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE INSTALL A 11.880 kW GRID-TIED PHOTOVOLTAIC SYSTEM TOTALING (36) PANASONIC HIT VBHN330SA16 SOLAR MODULES WITH (36) ENPHASE IQ7X-96-X-US MICRO-INVERTERS, FLUSH MOUNTED ON A COMPOSITE SHINGLE ROOF. INSTALL (2) TESLA POWERWALL 2 BATTERIES, CONNECTED TO 200A GEN PANEL AND INTERCONNECTED VIA MAIN LOAD CENTER. ALL SUPPLIED EQUIPMENT IS UL LISTED 2014 NATIONAL ELECTRIC CODE 2015 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE SCOPE OF WORK CODE COMPLIANCE PV-1 PV-2 PV-3 PV-4 - SYSTEM FOLLOWS ANY/ALL FIRE CODE SETBACKS PER ORDINANCES OF THE CITY OF SOUTHLAKE. - ALL PROJECTS WILL COMPLY WITH THE ORDINANCES OF THE CITY OF SOUTHLAKE. - PRODUCT DATA SHEETS WILL BE INCLUDED. - ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE - AREA OF ARRAY: 649.5 SQ. FT. PLANS 1 3' 16 ' - 6 " 5' 12'-6"26'-5"12'-9" (36) PANASONIC HIT VBHN330SA16 SOLAR MODULES AND (36) ENPHASE IQ7X-96-X-US MICRO-INVERTERS (N) IRONRIDGE ATTACHMENTS @ 72" MAX. SPAN (N) VISIBLE LOCKABLE LABELED AC DISCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL (N) 200A GEN PANEL (N) ENPHASE AC COMBINER (N) 2 TESLA POWERWALL BATTERIES FLORENCE RD (N) BACKUP GATEWAY 22'-3" 19 ' - 7 " PHOTOVOLTAIC MODULE SPECIFICATIONS APPROX. # OF ATTACHMENTS: 62 AREA OF ARRAY:649.5 SQ. FT. MODEL: WEIGHT: WIDTH: LENGTH: MAX. ROOF LOAD: MAX. POINT LOAD: PANASONIC HIT VBHN330SA16 40.81 LBS 41.5" 62.6" 2.79 LBS/SQFT 28.93 LBS/ATTACHMENT PROJECT NAME: DRAWN DATE: DRAWN BY: ARCHITECT/FIELD DRAWING INFORMATION PLAN ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. DRAWING NOTES: PHOTOVOLTAIC SOLAR MODULE MFG/MODEL: MODULE RATED AT: MULTIPLY BY QTY. OF MODULES: ARRAY SYSTEM SIZE: SYSTEM AZIMUTH: MOUNTING HEIGHT: ROOF PITCH: P: 469-209-5910 RESIDENCE JURISDICTION: ƒ -STORY :12 3165 FLORENCE RD SOUTHLAKE, TX 76262 CITY OF SOUTHLAKE 330 W 36 11.880 kW 180 1,12 1 TK 08/27/18 REV DESCRIPTION DATE GOOD FAITH ENERGY SOLAR LAYOUT SCALE: 3/32"=1'-0"1 PV-2 PLANS 2 IRONRIDGE L-FOOT W/ FLASHFOOT MOUNTING SYSTEM SCALE: 1"=1'-0"1  ƒ     ƒ IRONRIDGE MOUNTING CLAMP IRONRIDGE L-FOOT 2X6 RAFTER @ 24" OC TYP W/ PLYWOOD 12 SOLAR MODULE COMP. SHINGLE 5/16" x 3 1/2" SS LAG BOLT INTO RAFTER(S) 2 1/2" MIN. EMBEDMENT SEALED W/ GEOCEL. IRONRIDGE XR 100 RAIL, TYP. IRONRIDGE FLASHFOOT PHOTOVOLTAIC MODULE SPECIFICATIONS MODEL: WEIGHT: WIDTH: LENGTH: MAX. ROOF LOAD: MAX. POINT LOAD: PANASONIC HIT VBHN330SA16 40.81 LBS 41.5" 62.6" 2.79 LBS/SQFT 28.93 LBS/ATTACHMENT PROJECT NAME: DRAWN DATE: DRAWN BY: ARCHITECT/FIELD DRAWING INFORMATION PLAN ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. DRAWING NOTES: PHOTOVOLTAIC SOLAR MODULE MFG/MODEL: MODULE RATED AT: MULTIPLY BY QTY. OF MODULES: ARRAY SYSTEM SIZE: SYSTEM AZIMUTH: MOUNTING HEIGHT: ROOF PITCH: P: 469-209-5910 RESIDENCE JURISDICTION: ƒ -STORY :12 3165 FLORENCE RD SOUTHLAKE, TX 76262 CITY OF SOUTHLAKE 330 W 36 11.880 kW 180 1,12 1 TK 08/27/18 REV DESCRIPTION DATE GOOD FAITH ENERGY PV-3PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR ADHESIVE. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE, WILL BE INSTALLED AS REQUIRED. ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN METAL CONDUIT AND THE CONDUIT SHALL BE LABELED, "CAUTION DC CIRCUIT" OR EQUIVALENT EVERY 5 FT. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINT IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTRUCTIONS. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. ALL SOLAR MODULES, EQUIPMENT AND METALLIC COMPONENTS ARE TO BE BONDED. LABELS AC PHOTOVOLTAIC DISCONNECT WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.5(C) - AT THE INVERTER AND/OR GROUND FAULT INDICATOR LOCATION (AND ALL BATTERY LOCATIONS IF APPLICABLE): NEC 690.14(C)(2), 690.15 - ON AC DISCONNECT: NEC 690.17 - AT JUNCTION BOX, COMBINER BOXES AND AC/DC DISCONNECTS: WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(7) - BY BREAKER AT DISTRIBUTION EQUIPMENT: WARNING ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 690.35(F) - UNGROUNDED PV SYSTEMS ONLY AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: NEC 690.52 - ON AC DISCONNECT POINT OF INTERCONNECTION: CAUTION THE ELECTRICAL SYSTEM IS ALSO SERVICED BY A PHOTOVOLTAIC SYSTEM NEC 705.10 - AT SERVICE EQUIPMENT LOCATION: PHOTOVOLTAIC SYSTEM AC SYSTEM SPECIFICATIONS MAX. AC OUTPUT CURRENT: _______ OPERATING AC VOLTAGE: _______ OPERATING AC POWER:_______ OPERATING AC FREQUENCY: _______ MAXIMUM OCPD RATING: _______ PLANS 3 PLANS 4 PLANS 5 PLANS 6 PLANS 7 PLANS 8 PLANS 9 PLANS 10 The high-powered smart grid-ready Enphase IQ 7X Micro™ dramatically simplifies the installation process while achieving the highest system efficiency for systems with 96-cell modules. Part of the Enphase IQ System, the IQ 7X Micro integrates with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7X Microinverter To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Efficient and Reliable • Optimized for high powered 96-cell* modules • Highest CEC efficiency of 97.5% • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7X is required to support 96-cell modules. PLANS 11 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 INPUT DATA (DC)IQ7X-96-2-US and IQ7X-96-B-US Commonly used module pairings¹320 W - 460 W + Module compatibility 96-cell PV modules Maximum input DC voltage 80 V Peak power tracking voltage 53 V - 64 V Operating range 25 V - 80 V Min/Max start voltage 30 V / 80 V Max DC short circuit current (module Isc)10 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) Peak output power 320 VA Maximum continuous output power 315 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.31 A (240 VAC)1.51 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuit³12 (240 VAC)10 (208 VAC) Overvoltage class AC port III AC port backfeed current 0 A Power factor setting 1.0 Power factor (adjustable)0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V CEC weighted efficiency 97.5 %96.5 % MECHANICAL DATA Ambient temperature range -40ºC to +60ºC Relative humidity range 4% to 100% (condensing) Connector type (IQ7X-96-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7X-96-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7X Microinverter PLANS 12 Roof Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Software Online tool generates a complete bill of materials in minutes. Integrated Grounding UL 2703 system eliminates separate module grounding components. 20 Year Warranty Twice the protection offered by competitors. Built for solar’s toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Datasheet PLANS 13 © 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.42 XR Rails Attachments Clamps & Grounding Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/rm MacBook Pro NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Free Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear & black anod. finish Internal Splices All rails use internal splices for seamless connections. • Self-tapping screws • Varying versions for rails • Grounding Straps offered FlashFoot Anchor, flash, and mount with all-in-one attachments. • Ships with all hardware • IBC & IRC compliant • Certified with XR Rails Slotted L-Feet Drop-in design for rapid rail attachment. • High-friction serrated face • Heavy-duty profile shape • Clear & black anod. finish Standoffs Raise flush or tilted systems to various heights. • Works with vent flashing • Ships pre-assembled • 4” and 7” Lengths Tilt Legs Tilt assembly to desired angle, up to 45 degrees. • Attaches directly to rail • Ships with all hardware • Fixed and adjustable End Clamps Slide in clamps and secure modules at ends of rails. • Mill finish & black anod. • Sizes from 1.22” to 2.3” • Optional Under Clamps Grounding Mid Clamps Attach and ground modules in the middle of the rail. • Parallel bonding T-bolt • Reusable up to 10 times • Mill & black stainless T-Bolt Grounding Lugs Ground system using the rail’s top slot. • Easy top-slot mounting • Eliminates pre-drilling • Swivels in any direction Accessories Provide a finished and organized look for rails. • Snap-in Wire Clips • Perfected End Caps • UV-protected polymer XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish PLANS 14 N330/N325 Quality and Reliability Panasonic’s vertical integration, 20 years of experience manufacturing HIT® and 20 internal tests beyond those mandated by current standards provides extreme quality assurance. Higher Efficiency 19.7% Enables higher power output and greater energy yields. HIT® provides maximum production for your limited roof space. Unique water drainage The water drainage system give rain, water and snow melt a place to go, reducing water stains and soiling on the panel. Less dirt on the panel means more sunlight getting through to generate power. Low Degradation HIT “N-type” cells result in extremely Low Light Induced Degradation (LID) and zero Potential Induced Degradation (PID) which supports reliability and longevity. This technology reduces annual degradation to 0.26% compare to 0.70% in conventional panels, guaranteeing more power for the long haul. Our competitive advantages High Efficiency at High Temperatures As temperature increases, HIT® continues to perform at high levels due to the industry leading temperature coefficient of -0.258% /⁰C. No other module even comes close to our temperature characteristics.  That means more energy throughout the day. 25 Year Product and Performance Warranty** Industry leading 25 year product workmanship and performance warranty is backed by a century old company- Panasonic. Power output is guaranteed to 90.76% after 25 years, far greater than other companies. Panasonic’s unique heterojunction technology uses ultra-thin amorphous silicon layers. These thin dual layers reduce losses, resulting in higher energy output than conventional panels. Advanced bifacial cell designed for increased energy output. The cell utilizes sunlight reflected back from the rear side material which captures more light and converted into energy. n-type crystalline silicon Double-sided textured surface i-type amorphous layer Amorphous layer Transparent electrode (TCO) Lattice-type electrodes Finger Tab These amorphous silicon layers reduces the recombination ofelectrons to minimum level. Electrodes Ultra-thin amorphous silicon layer HIT® is a registered trademark of Panasonic GroupPLANS15 CAUTION! Please read the installation manual carefully before using the products. Used electrical and electronic products must not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points in accordance with your national legislation. Panasonic Eco Solutions of North America Two Riverfront Plaza, 5th Floor, Newark, NJ 07102 panasonicHIT@us.panasonic.com business.panasonic.com/solarpanels All Rights Reserved © 2017 COPYRIGHT Panasonic Corporation Specifications are subject to change without notice 04/2017 RS17170_DS DEPENDENCE ON IRRADIANCE Reference data for model: VBHN330SA16 (Cell temperature: 25°C) PERFORMANCE WARRANTY 97% 90.76% 80% More power over 25 years N330/N325 ELECTRICAL SPECIFICATIONS Model VBHN330SA16 VBHN325SA16 Rated Power (Pmax)¹330W 325W Maximum Power Voltage (Vpm) 58.0V 57.6V Maximum Power Current (lpm)5.70A 5.65A Open Circuit Voltage (Voc) 69.7V 69.6V Short Circuit Current (lsc) 6.07A 6.03A Temperature Coefficient (Pmax) -0.258%/°C -0.258%/°C Temperature Coefficient (Voc) -0.16V/°C -0.16V/°C Temperature Coefficient (lsc) 3.34mA/°C 3.32mA/°C NOCT 44.0°C 44.0°C CEC PTC Rating 311.3W 306.5W Cell Efficiency 22.09%21.76% Module Efficiency 19.7%19.4% Watts per Ft.²18.3W 18.0W Maximum System Voltage 600V 600V Series Fuse Rating 15A 15A Warranted Tolerance (-/+)+10%/-0%*+10%/-0%* MECHANICAL SPECIFICATIONS Model VBHN330SA16, VBHN325SA16 Internal Bypass Diodes 4 Bypass Diodes Module Area 18.02 Ft.² (1.67m²) Weight 40.81 Lbs. (18.5kg) Dimensions LxWxH 62.6x41.5x1.4 in. (1590x1053x35 mm) Cable Length +Male/-Female 40.2/40.2 in. (1020/1020 mm) Cable Size / Type No. 12 AWG / PV Cable Connector Type2 Multi-Contact® Type IV (MC4™) Static Wind / Snow Load 50 PSF (2400 Pa) Pallet Dimensions LxWxH 63.7x42.2x65.4 in. Quantity per Pallet / Pallet Weight 40 pcs. /1719 Lbs. (780 kg) Quantity per 40' Container 560 pcs. Quantity per 20' Container 240 pcs. OPERATING CONDITIONS & SAFETY RATINGS Model VBHN330SA16, VBHN325SA16 Operating Temperature -40°F to 185°F (-40°C to 85°C) Hail Safety Impact Velocity 1" hailstone (25mm) at 52 mph (23m/s) Safety & Rating Certifications UL 1703, cUL, CEC UL 1703 Fire Classification Type 2 Limited Warranty 25** Yrs Workmanship and Power Output (Linear)*** DIMENSIONS 41.5[1053]1.38[35]20.3[516.5] 4. 4 1 [ 1 1 2 ] 1. 4 8 [ 3 7 . 5 ] 31 . 3 [ 7 9 5 ] 62 . 6 [ 1 5 9 0 ] 40 . 2 [ 1 0 2 0 ] 5. 4 7 [ 1 3 9 ] 7 . 9 7 [ 2 0 2 . 5 ] 1. 4 8 [ 3 7 . 5 ] 1. 3 7 8 [ 3 5 ] 1. 3 7 8 [ 3 5 ] 0. 0 5 9 [ 1 . 5 ] 0. 1 1 8 [ 3 ] 0.994[25.25] 1.457[37]1.260[32] 0.797[20.25] 39.7[1009] Mount Locations 41.5[1053]1.38[35]20.3[516.5] 4. 4 1 [ 1 1 2 ] 1. 4 8 [ 3 7 . 5 ] 31 . 3 [ 7 9 5 ] 62 . 6 [ 1 5 9 0 ] 40 . 2 [ 1 0 2 0 ] 5. 4 7 [ 1 3 9 ] 7 . 9 7 [ 2 0 2 . 5 ] 1. 4 8 [ 3 7 . 5 ] 1. 3 7 8 [ 3 5 ] 1. 3 7 8 [ 3 5 ] 0. 0 5 9 [ 1 . 5 ] 0. 1 1 8 [ 3 ] 0.994[25.25] 1.457[37]1.260[32] 0.797[20.25] 39.7[1009] Mount Locations Unit: inches (mm) NOTE: Standard Test Conditions: Air mass 1.5; irradiance = 1000W/m²; cell temp. 25°C * Maximum power at delivery. For guarantee conditions, please check our guarantee document. ** Installation need to be registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year Product workmanship. Otherwise, Product Workmanship will be only fifteen (15) years. *** 1st year 97%, after 2nd year 0.26% annual degradation to year 25. 1 STC: Cell temp. 25°C, AM1.5, 1000W/m² 2 Safety locking clip (PV-SSH4) is not supplied with the module. NOTE: Specifications and information above may change without notice. PLANS 16