Loading...
Item 7B PlansCO N C E P T P L A N P A C K A G E : SO U T H W E S T M E A D O W S To Serve ADAMS PROJECT NO. 2017.129 CIVIL ENGINEER ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM SOUTHWEST MEADOWS CONCEPT PLAN AND SITE PLAN PACKAGE FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n \ S 1 . 0 C O V E R S H E E T PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 PL O T T E D A T : 10 : 2 5 : 0 1 A M PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D B Y : Mi k e P e t e r s o n FI L E N A M E : S1 . 0 C O V E R S H E E T . d w g June 2018 SURVEYOR DUNAWAY 550 BAILEY AVE., SUITE 400 FORT WORTH, TEXAS 76107 CONTACT: STEPHEN R. GLOSUP, R.P.L.S. PHONE: 871-335-1121 EMAIL: SRG@DUNAWAY-ASSOC.COM SITE MAP SCALE: NTS IN THE CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS APPLICANT / ARCHITECT HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM LANDSCAPE ARCHITECT ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: BEN HENRY, PLA. PHONE: (817) 328-3200 EMAIL: BEN.HENRY@ADAMS-ENGINEERING.COM 8951 Cypress Waters Bld, Ste 150 ■ Dallas, Texas 75019 ■ (817) 328-3200 PROJECT LOCATION CASE NO: ZA18-006 LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 Sheet List Table Sheet Number Sheet Title S1.0 COVER SHEET S2.0 ALTA SURVEY S2.1 ALTA SURVEY S2.2 TOPOGRAPHIC AND TREE SURVEY S2.3 TOPOGRAPHIC AND TREE SURVEY S3.0 CONCEPT PLAN S3.1 CONCEPT PLAN DATA SHEET S3.2 SITE PLAN LOT 1 S4.0 TREE CONSERVATION PLAN S5.0 GRADING PLAN S5.1 GRADING PLAN LOT 1 S5.2 PRE-DEVELOPED DRAINAGE AREA MAP S5.3 POST-DEVELOPED DRAINAGE AREA MAP & DRAINAGE PLAN S6.0 PRELIMINARY UTILITY PLAN S7.0 CONCEPT LANDSCAPE PLAN S7.1 LANDSCAPE PLAN LOT 1 S8.0 PEDESTRIAN ACCESS & OPEN SPACE MANAGEMENT PLAN S9.0 CONSTRUCTION PHASE 1 PLAN PRELIMINARY FOR REVIEW PURPOSES ONLY KI R K W O O D B O U L E V A R D STATE HIGHWAY 114 EX-PL EX-PL∆ ∆ ∆ 405' P O R T E C O C H E R E LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF LOT 2 51,029 SF (±1.169 AC) FFE = 596.00 BLDG = 5,000 SF LOT 3 50,465 SF (±1.160 AC) FFE = 596.00 BLDG = 5,000 SF LOT 4 37,979 SF (±.873 AC) FFE = 588.00 BLDG = 5,000 SF FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIR E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E FIR E L A N E ∆ S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S 3 8 ° 5 1 ' 1 0 " W 1 2 4 . 6 7 ' N51° 0 8 ' 5 0 " W 162.01 ' N51° 0 8 ' 5 0 " W 99.15' N 0 8 ° 0 9 ' 3 0 " E 9 8 . 6 8 ' N81 ° 5 0 ' 4 0 " W 43. 8 7 ' S7 1 ° 1 2 ' 2 0 " W 21 7 . 8 6 ' N 0 8 ° 0 9 ' 3 0 " E 1 3 7 . 6 5 ' N7 1 ° 4 9 ' 3 0 " E 33 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60' EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W FH FH FH FH SS SS SST T T T P P FH FH FH FH SS SS SS 17 11 5 3 EFFECTIVE 500 YEAR FLOOD PLAIN EFFECTIVE 100 YEAR FLOOD PLAIN AND NATURAL STREAM BUFFER RETAINING WALL DOUBLE TRASH ENCLOSURE 10'X50' LOADING ZONE 25' BUILDING SETBACK 12 13 12 11 12 9 3 10 2 10L 5 8 8 8 8 5 8 6L 17L 9L ROW DEDICATION .38 AC (16,553 SF) R30' R54' R30' R30' R31' R30' R30' R54' R112' R87' R30' R54' R30' R30' R30' R30' R54' R30' R30' R30' 2 4 ' F I R E L A N E E A S ' M T 2 4 ' F I R E L A N E E A S ' M T NEXT DRIVE DOVE ROA D RETAINING WALL SHARED TRASH ENCLOSURE (LOTS 2 & 3) 231' 445' TRASH ENCLOSURE 25' TYPE 'J' BUFFER YARD 1 2 ' M I N . B T O B ( T Y P . ) 10' TYPE 'B' BUFFER YARD 10' TYPE 'B' BUFFER YARD 47' S T A C K I N G DE P T H 47' S T A C K I N G DEP T H 7 5 ' S T A C K I N G D E P T H 30' BUILDING SETBACK 16L 18U 9U 17U 7U 13U 5L LEGEND C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 05/31/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 CO N C E P T P L A N S3.0 GRA                     FI L E N A M E : S3 . 0 C O N C E P T P L A N . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : Th u r s d a y , M a y 3 1 , 2 0 1 8 PL O T T E D A T : 12 : 4 4 : 3 4 P M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n \ S 3 . 0 C O N C E P T P L A N   2017.129 DWL LMG CASE NO: ZA18-006 CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM NTS SITE MAP PROJECT LOCATION LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TXPRELIMINARY FOR REVIEW PURPOSES ONLY PROPOSED FACE AND BACK OF CURB PROPOSED VEHICULAR PAVEMENT PROPOSED SIDEWALK OPEN SPACE PROPOSED RETAINING WALL PROPOSED FIRE HYDRANT PROPOSED SANITARY MANHOLE PROPOSED CURB INLET PARKING COUNT ACCESSIBLE ROUTE PERMISSIBLE BUILDING AREA BACK OF CURB TO BACK OF CURB BUILDING SETBACK LINE BUFFERYARD FH S S 1 ARTICLE V11 - PARK AND RECREATION DEDICATION REQUIREMENTS. SECTION 7.03-2 LAND DEDICATION REQUIREMENTS Non-Residential Developments: Although non-residential development does not generate residential occupancies per se, it does create environmental impacts which may negatively affect the living environment of the community. These impacts may be ameliorated or eliminated by providing park or open space areas which buffer adjoining land uses, prevent undue concentration of paved areas, allow for the reasonable dissipation of automotive exhaust fumes, provide natural buffers to the spread of fire or explosion, and provide separation of lighting, waste disposal, and noise by-products of non-residential operations and activities from adjacent residential areas. The City has therefore determined that non-residential developments must provide dedicated parks and/or reserved open space at a ratio of one (1) acre of park land for every fifty (50) non-residential gross acres of development or prorated portion thereof. GRAPHIC SCALE FEET08040 1"=40' PEDESTRIAN ACCESS ROUTE AS SHOWN ALONG 6' WIDE SIDEWALKS PEDESTRIAN ACCESS B TO B *PARKING WILL BE MET PER THE "S-P-2" REGULATIONS FOR THE SITE AS A WHOLE AND NOT ON A LOT BY LOT BASIS LANDSCAPE REQUIREMENT FOR THE CITY OF SOUTHLAKE Site Data Summary Lot 1 Lot 2 Lot 3 Lot 4 Total Existing Zoning NRPUD NRPUD NRPUD NRPUD NRPUD Proposed Zoning SP-2 SP-3 SP-4 SP-5 SP-6 Land Use Designation MIXED USE MIXED USE MIXED USE MIXED USE MIXED USE Gross Acreage 2.424 1.201 1.338 1.044 6.007 ROW Dedication -0.03 0.179 0.172 0.38 Net Acreage 2.424 1.171 1.159 0.872 5.626 Number of Proposed Lots 1 1 1 1 4 Percentage of Site Coverage 15.21%9.80%9.90%13.16%12.67% Area of Open Space (Acres)0.682 0.581 0.422 0.259 1.944 Percentage of Open Space 28.14%49.62%36.41%29.70%34.91% Area of Impervious Coverage (Acres)1.742 0.59 0.737 0.613 3.682 Percentage of Impervious Coverage 71.86%50.38%63.59%70.30%65.09% Proposed Building Area (Foot Print in Sq. Ft.) P.B.A.16,055 5,000 5,000 5,000 31,055 Number of Stories 5 1 1 1 Maximum Building Height 60'35'35'35'- Proposed Floor Area (Square Feet)80,700 5000 5000 5000 95,700 Proposed Floor Area by Use (Square Feet) Hotel (Square Feet)77,200 0 0 0 77,200 Restaurant (Square Feet)3,500 5,000 5,000 5,000 18,500 Required Parking (Per S-P-2 Regulations)138 50 50 50 288 Provided Parking Standard (9'X18')115 30 45 95 285 ADA Accessible 6 4 0 2 12 Total 121 34 45 97 297 Required Loading Spaces 10' x 25'----- 10' x 50'1 ---1 Provided Loading Spaces 10' x 25'----- 10' x 50'1 ---1 Start Construction Month/Year Oct-2018 Feb-2019 Jan-2020 Sep-2020 Jun-2018 End Construction Month/Year Jun-2019 Sep-2019 Aug-2020 May-2021 May-2021 K I R K W O O D B O U L E V A R D STA T E H I G H W A Y 1 1 4 EX- P L ∆ PORTE COCHERE FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELANE FIRELANE FIRELANE FIRELANE FIRELANE FIRE L A N E FI R E L A N E FI R E L A N E FIRELANE F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FIRELA N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIRE L A N E F I R E L A N E FI R E L A N E FIRELA N E F I R E L A N E ∆ S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S3 8 ° 5 1 ' 1 0 " W 12 4 . 6 7 ' N5 1 ° 0 8 ' 5 0 " W 16 2 . 0 1 ' N5 1 ° 0 8 ' 5 0 " W 99 . 1 5 ' N08° 09' 30"E 98.68' N8 1 ° 5 0 ' 4 0 " W 43 . 8 7 ' S 7 1 ° 1 2 ' 2 0 " W 2 1 7 . 8 6 ' N08° 09' 30"E 137.65' N 7 1 ° 4 9 ' 3 0 " E 3 3 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60 ' FH FH FH SS SS SS T T T P P FH FH SS SS SS 17 11 5 RET A I N I N G W A L L DOUBLE TRASH ENCLOSURE 10'X50' LOADING ZONE 8 8 3 8 10 2 8 6U 6L ROW D E D I C A T I O N .38 A C ( 1 6 , 5 5 3 S F ) R30' R54' R30' R30' R31' R30' R30' R54' R112' R87' R30' R54' R30' R30' R30' R30' R54' R30' R30' R30' 24' FIRE LANE EAS'MT 24' F I R E L A N E E A S ' M T TRA S H ENC L O S U R E 25' TYPE 'J' BUFFER YARD 12' MIN. B TO B (TYP.) 10' TYPE 'B' BUFFER YARD 10' TYPE 'B' BUFFER YARD LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF 1 1 1 2 PROPOSED 4' WIDE SIDE WALK 3 3 PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT 5' WIDE SIDEWALK 2 22 4L 5L 7U 1L 1U 3 8 2 2 LOT 2 51,0 2 9 S F (±1 . 1 6 9 A C ) FFE = 5 9 6 . 0 0 BLD G = P . B . A . 6 , 7 0 0 S F LOT 3 50,4 6 5 S F (±1 . 1 6 0 A C ) FFE = 5 9 6 . 0 0 BLD G = P . B . A . 6 , 0 0 0 S F LOT 4 37,9 7 9 S F (±.8 7 3 A C ) FFE = 5 8 8 . 0 0 BLD G = P . B . A . 6 , 0 0 0 S F F I R E L A N E FIRELANE FI R E L A N E FI R E L A N E LOT 1 STA T E H I G H W A Y 1 1 4 ∆ F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E F I R E L A N E FI R E L A N E FIRELA N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIRE L A N E F I R E L A N E FI R E L A N E FIRELA N E F I R E L A N E S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S3 8 ° 5 1 ' 1 0 " W 12 4 . 6 7 ' N5 1 ° 0 8 ' 5 0 " W 99 . 1 5 ' N08° 09' 30"E 98.68' N8 1 ° 5 0 ' 4 0 " W 43 . 8 7 ' N08° 09' 30"E 137.65' N 7 1 ° 4 9 ' 3 0 " E 3 3 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60 ' SS SS P SS SS 8 8 3 8 8 R30' R31' R30' R30' R112' R87' R30' R54' R30' R30' R30' R54' 24' F I R E L A N E E A S ' M T PROPOSED 4' WIDE SIDE WALK 8 FI R E L A N E FI R E L A N E FI R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S3 8 ° 5 1 ' 1 0 " W 12 4 . 6 7 ' N5 1 ° 0 8 ' 5 0 " W 16 2 . 0 1 ' SS T FH 6U R30' R30' R54' TRA S H ENC L O S U R E 25' TYPE 'J' BUFFER YARD 3 PROPOSED FIRE HYDRANT 4L LEGEND C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 05/31/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 SI T E P L A N LO T 1 S3.2 GRA                     FI L E N A M E : S3 . 1 S I T E P L A N L O T 1 . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : Th u r s d a y , M a y 3 1 , 2 0 1 8 PL O T T E D A T : 10 : 5 4 : 4 8 A M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n \ S 3 . 1 S I T E P L A N L O T 1   2017.129 DWL LMG CASE NO: ZA18-006 LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX PRELIMINARY FOR REVIEW PURPOSES ONLY PROPOSED FACE AND BACK OF CURB PROPOSED VEHICULAR PAVEMENT PROPOSED SIDEWALK OPEN SPACE PROPOSED RETAINING WALL PROPOSED FIRE HYDRANT PROPOSED SANITARY MANHOLE PROPOSED CURB INLET PARKING COUNT ACCESSIBLE ROUTE PERMISSIBLE BUILDING AREA BACK OF CURB TO BACK OF CURB FH S S 1 GRAPHIC SCALE FEET06030 1"=30' P.B.A B TO B TYPICAL ACCESSIBLE PARKING SPACES SEE PAVING DETAILS (TYP) INSTALL BARRIER FREE RAMP (BFR) REFER TO PAVING DETAILS. (TYP) 1 2 3 PROPOSED CURB INLET, GRATE INLET, OR VANE DRAIN (REF DRAINAGE PLAN) SYMBOL KEY SITE PLAN KEY MAP CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM *PARKING WILL BE MET PER THE "S-P-2" REGULATIONS FOR THE SITE AS A WHOLE AND NOT ON A LOT BY LOT BASIS !!!CAUTION!!! EXISTING OVERHEAD & UNDERGROUND UTILITIES IN THE VICINITY. VERIFY LOCATION OF EXISTING UNDERGROUND UTILITIES BY VACUUM EXCAVATION OR OTHER POTHOLING TECHNIQUES. Know what's below. before you dig.Call R THESE PLANS ARE SUBJECT TO REVIEW & APPROVAL BY JURISDICTIONAL ENTITIES. Site Data Summary Lot 1 Existing Zoning NRPUD Proposed Zoning SP-2 Land Use Designation MIXED USE Gross Acreage 2.424 ROW Dedication - Net Acreage 2.424 Number of Proposed Lots 1 Percentage of Site Coverage 15.21% Area of Open Space (Acres)0.682 Percentage of Open Space 28.14% Area of Impervious Coverage (Acres)1.742 Percentage of Impervious Coverage 71.86% Proposed Building Area (Foot Print in Sq. Ft.) P.B.A.16,055 Number of Stories 5 Maximum Building Height 60' Proposed Floor Area (Square Feet)80,700 Proposed Floor Area by Use (Square Feet) Hotel (Square Feet)77,200 Restaurant (Square Feet)3,500 Required Parking (Per S-P-2 Regulations)138 Provided Parking Standard (9'X18')115 ADA Accessible 6 Total 121 Required Loading Spaces 10' x 25'- 10' x 50'1 Provided Loading Spaces 10' x 25'- 10' x 50'1 Start Construction Month/Year Oct-2018 End Construction Month/Year Jun-2019 P O R T E C O C H E R E LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF LOT 2 51,029 SF (±1.169 AC) FFE = 596.00 BLDG = 5,000 SF LOT 3 50,465 SF (±1.160 AC) FFE = 596.00 BLDG = 5,000 SF LOT 4 37,979 SF (±.873 AC) FFE = 588.00 BLDG = 5,000 SF FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIR E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E FI R E L A N E F I R E L A N E FIRELA N E FI R E L A N E FIR E L A N E S0 6 ° 0 6 ' 1 1 " E 7 1 . 0 5 ' S 0 8 ° 1 3 ' 2 9 " W 1 7 2 . 5 4 ' S 0 6 ° 3 1 ' 5 2 " W 1 8 2 . 8 8 ' S 2 8 ° 0 7 ' 0 9 " W 1 1 9 . 4 9 ' =2 1 ° 1 0 ' 4 5 " R= 1 4 1 9 . 5 0 ' L = 5 2 4 . 7 1 ' CH = N 7 3 ° 1 8 ' 2 6 " E 5 2 1 . 7 3 ' HE L D RO T A T E D U . P . M A R T I N S U R V E Y A B S T R A C T N O . 1 0 1 5 KI R K W O O D B O U L E V A R D (1 3 1 ' W I D T H P U B L I C R I G H T - O F - W A Y ) CO N C R E T E P A V I N G C. C . D . N O D 2 1 5 2 3 2 7 5 1 D. R . T . C . T . STATE HIGHWAY 114 (VARIABLE WIDTH PUBLIC RIGHT-OF-WAY) CONCRETE PAVING DIRECTIONAL CONTROL LINE = 9 9 ° 1 8 ' 4 0 " R = 9 0 . 0 0 ' L = 1 5 6 . 0 0 ' C H = N 1 3 ° 0 3 ' 5 5 " E 1 3 7 . 1 9 ' =6°26'28" R=1452.40' L=163.28' CH=N33°22'03"W 163.19' N30°08'49"W 232.63'N32°38'51"W 129.99' S 3 7 ° 0 2 ' 5 7 " W 1 6 8 . 0 5 ' S 4 6 ° 3 3 ' 5 5 " W 1 2 0 . 1 0 ' S 2 8 ° 0 7 ' 0 9 " W 1 1 9 . 4 9 ' S 0 6 ° 3 1 ' 5 2 " W 1 8 2 . 8 8 ' S 0 8 ° 1 3 ' 2 9 " W 1 7 2 . 5 4 ' S0 6 ° 0 6 ' 1 1 " E 7 1 . 0 5 ' =2 1 ° 1 0 ' 4 5 " R= 1 4 1 9 . 5 0 ' L = 5 2 4 . 7 1 ' CH = N 7 3 ° 1 8 ' 2 6 " E 5 2 1 . 7 3 ' N6 2 ° 4 3 ' 0 3 " E 32 . 2 5 ' AP P R O X I M A T E L O C A T I O N O F 65 L D N A I R P O R T O V E R L A Y L I N E SC A L E D F R O M P L A T R E C O R D E D IN C A B I N E T A , S L I D E 1 2 2 1 6 P.R . T . C . T . ZO N E " X " S H A D E D ZO N E " X " U N S H A D E D ZO N E " X " S H A D E D EX-PL EX-PL WILKS S O U T H L A K E D E V E L O P M E N T , L L C C.C.D. N O . D 2 1 3 1 6 8 1 2 1 D.R.T.C. T . LOT 1R 1 R 2 , B L O C K 1 SABRE G R O U P C A M P U S A D D I T I O N C.C.D. N O . D 2 1 5 2 2 1 5 6 2 P.R.T.C. T . TD A M E R I T R A D E S E R V I C E S C O M P A N Y , I N C . C.C.D. N O . D 2 1 5 2 3 5 0 0 1 D.R.T. C . T . LOT 1 R 1 R 1 , B L O C K SABR E G R O U P C A M P U S A D D I T I O N C.C.D . N O . D 2 1 5 2 2 1 5 6 2 P.R.T. C . T . N6 2 ° 4 3 ' 0 3 " E 32 . 2 5 ' WM W M WM 104 0 104 1 117 3 117 4 117 5 117 6 117 7 117 8 117 9 118 0 118 1 118 2 118 3 118 4 118 5 119 9 120 0 120 1 120 2 120 3 12 0 4 162 9 163 0 163 1 163 2 163 3 163 4 163 5 163 7 163 8 16 3 9 164 0 1641 164 2 1643 164 4 164 5 164 6 164 7164 8 164 9 165 0 165 1 1 6 5 2 165 3 1655 16 5 6 165 7 16 6 0 1 6 6 1 16 6 2 1 6 6 3 166 4 1665 166 6 16 6 7 16 6 8 16 6 9 167 0 167 1 167 3 167 4 167 5 167 6 167 7 167 9 168 0 168 7 168 8 168 9 169 0 1691 169 2 169 3 169 4 169 5 169 6 169 7 169 8 169 9 170 0 170 1 170 2 170 3 170 7 170 8 170 9 171 0 303 8 304 1 304 3 304 4 304 9 305 1 305 5 305 6 305 7 305 9 3 0 6 0 306 1 306 2 306 3 30 6 4 306 5 306 6 30 6 7 306 8 306 9 3 0 7 0 307 1 307 2 3073 3074 30 7 5 3076 3077 307 8 3079 308 0 3 0 8 1 308 2 30 8 3 308 4 308 6 308 7 308 8 308 9 309 0 309 1 3092 30 9 3 309 4 30 9 5 309 7 30 9 8 309 9 310 0 310 1 310 2 310 3 310 4 310 5 310 6 3107 310 8 31 0 9 3 1 1 0 31 1 1 311 2 3113 3114 311 5 312 2 312 3 312 5 313 0 313 1 172 0 172 1 172 2 172 3 17 2 4 172 5 172 7 172 8 172 9 173 0 173 1 173 2 173 3 173 4 173 5 173 6 173 7173 8 174 0 174 1 174 2 17 4 4 174 5 174 6 174 7 174 8 174 9 175 0 175 1 175 2 175 3 175 4 175 5 175 6 175 7 175 8 175 9 176 0 176 1 176 2 1764 176 5 1766 176 7 17 6 8 17 6 9 177 0 177 1 177 2 177 4 177 7 177 8 177 9 178 0 178 1 178 2 178 3 178 4 178 5 178 6 178 8 1789 17 9 0 313 3 313 4 313 5 313 6 313 7 313 8 313 9 314 0 314 1 314 2 314 3 314 4 314 5 314 6 314 7 314 8 314 9 315 0 315 1 315 2 315 3 315 4 315 5 315 6 316 3 316 4 316 5316 6 317 5 317 6 317 7 317 8 317 9 318 2 318 3 318 8 318 9 319 0 319 1 319 2 319 3 319 4 319 5 319 6 319 7 319 8 319 9 320 0 320 1 32 0 2 320 3 32 0 4 3 2 0 5 3 2 0 6 320 7 CO SD SD ! !! ! ! ! ! ! ! ! ! ! ! EB E B EB EB EB TVT TVT TVT TVT D- 9 4 3 7 - 1 1 2 7 C& B C& B C& B C& B C& B C& B AC C E S S GR A N T E D AC C E S S DE N I E D 5 8 5 585 5 9 0 59 0 59 5 59 5 6 0 0 60 0 58 1 58 1 582 5 8 3 58 3 5 8 4 58 4 5 8 6 58 6 5 8 7 58 7 5 8 8 588 5 8 9 589 59 1 59 1 59 2 59 2 59 3 59 3 59 4 59 4 59 6 59 6 59 7 59 7 59 8 59 8 5 9 9 59 9 601 60 1 58 0 5 8 5 5 9 0 59 5 578 57 9 58 1 58 2 58 3 5 8 4 5 8 6 5 8 7 5 8 8 5 8 9 5 9 1 5 9 2 5 9 3 5 9 4 59 6 59 7 5 9 8 5 9 9 5 8 0 5 8 5 5 7 9 5 8 1 5 8 2 5 8 3 5 8 4 5 8 6 585 590 595 600 584 586 587 588 589 591 592 593 594 596 597 598 599 601 585 58 1 5 8 1 5 8 2 58 2 582 58 3 584 58 0 580 585 5 9 0 5 9 5 600 57 6 576 57 7 577 57 8 578 57 9 579 58 1 581 582 58 2 583 58 3 584 5 8 4 5 8 6 5 8 7 58 8 58 9 5 9 1 5 9 2 5 9 3 594 59 6 59 7 598 599 601 585 58 5 581 582 583 584 F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E FI R E L A N E UN D E R G R O U N D GA S L I N E 10 . d . 10 ' W A T E R E A S E M E N T CA B I N E T A , S L I D E 7 2 1 2 P.R . T . C . T . 10 . d . 10 ' U T I L I T Y E A S E M E N T CA B I N E T A , S L I D E 7 2 1 2 P.R . T . C . T . 10 ' U T I L I T Y E A S E M E N T 10 . g . OV E R F L O W E A S E M E N T TR A C T N O . C - 2 5 6 A VO L U M E 4 5 5 8 , P A G E 5 0 5 D.R . T . C . T . SA B R E G R O U P C A M P U S CA B I N E T A , S L I D E 7 2 1 2 P.R . T . C . T . 10 . d . 15 ' E L E C T R I C E A S E M E N T CA B I N E T A , S L I D E 7 2 1 2 P. R . T . C . T . 10 d . 25 ' P E D E S T R A I N E A S E M E N T VO L U M E 9 4 3 7 , P A G E 1 1 2 7 D. R . T . C . T . CO N C R E T E P A V I N G CO N C R E T E P A D CO N C R E T E P A D 30 ' B U I L D I N G L I N E CA B I N E T A , S L I D E 7 2 1 2 P. R . T . C . T . 50 ' B U I L D I N G L I N E CA B I N E T A , S L I D E 7 2 1 2 P.R . T . C . T . Walnut Grove Park SA M S C H O O L KIRKWO O D BLVD KING T W 1 1 4 C I T Y L I M I T W E S T L A K E KI R K W O O D BL V D 1 1 4 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF LANDSCAPE ARCHITECT No. 1826, ON ---- THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES BEN R. HENRY, ASLA TREES TO BE REMOVED TREES IN PUBLIC R.O.W. THAT MAY BE PRESERVED PENDING UTILITY AND/OR VEHICULAR CIRCULATION CONNECTIONS TO KIRKWOOD BLVD. LEGEND REFERENCE PRELIMINARY TOPOGRAPHIC / TREE SURVEY COMPLETED BY DUNAWAY DATED FEBRUARY 17, 2017 FOR TREE SIZE AND SPECIES EXISTING TREE INVENTORY LIST - NO STREAMS / CREEKS / PONDS EXIST ON SITE - CRITICAL ROOT ZONES ARE LOCATED WITHIN DRIPLINE OF TREES. SITE NOTES GROSS SITE AREA (6.00 ACRES):261,539 SF EXISTING TREE CANOPY AREA:96,859 SF % OF SITE AREA:38.0% EXISTING TREE CANOPY PROPOSED TO BE REMOVED:96,859 SF % OF CANOPY TO BE REMOVED:100.0% EXISTING TREE CANOPY PROPOSED TO REMAIN:0 SF % OF CANOPY TO REMAIN:0.0% EXISTING TREE CANOPY IN R.O.W. THAT MAY BE PRESERVED:561 SF % OF CANOPY POTENTIALLY PRESERVED WITHIN PROPERTY:0.0% * NOTE : TREE CANOPY CALCULATIONS ARE APPROXIMATE BASED ON TREE LOCATIONS FROM TREE SURVEY COMBINED WITH AERIAL IMAGERY. TABULATION OF TREE REMOVAL ASSUMES NO TREES ARE TO BE PRESERVED. HOWEVER AS DESIGN DOCUMENTS PROGRESS, EFFORTS WILL BE MADE TO IDENTIFY AND PRESERVE ALL POTENTIAL TREES PRIOR TO EXECUTION OF MITIGATION TREE TABULATIONS SEE SEC. 9.5-379 - 'TREE REPLACEMENT AND TREE PROTECTION STANDARDS' IN THE CITY OF SOUTHLAKE CODE OF ORDINANCES. TREE REPLACEMENT & PROTECTION PROCEDURES FOR the City of Southlake TR E E C O N S E R V A T I O N P L A N S4.0 FI L E N A M E : S4 . 0 T R E E C O N S E R V A T I O N P L A N . d w g PL O T T E D B Y : Ja m e s K i n d r e d PL O T T E D O N : Th u r s d a y , F e b r u a r y 2 2 , 2 0 1 8 PL O T T E D A T : 2: 2 4 : 4 3 P M PL O T T E D W I T H : No n e FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n I : \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n \ S 4 . 0 T R E E C O N S E R V A T I O N P L A N BRH 2017-129 JWN JRK NTS SITE MAP PROJECT LOCATION GRAPHIC SCALE FEET08040 1"=40' CASE NO:ZA18-006 LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 2 0 1 4 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 D a l l a s , T e x a s 7 5 0 1 9 ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM PRELIMINARY FOR REVIEW PURPOSES ONLY EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W FH FH W FH FH SS SS SST T T T P P FH FH W W W FH FH SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W P O R T E C O C H E R E LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF LOT 2 51,029 SF (±1.169 AC) FFE = 596.00 BLDG = 5,000 SF LOT 3 50,465 SF (±1.160 AC) FFE = 596.00 BLDG = 5,000 SF LOT 4 37,979 SF (±.873 AC) FFE = 588.00 BLDG = 5,000 SF FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIR E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E FIR E L A N E ∆ S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S 3 8 ° 5 1 ' 1 0 " W 1 2 4 . 6 7 ' N51° 0 8 ' 5 0 " W 162.01 ' N51° 0 8 ' 5 0 " W 99.15' N 0 8 ° 0 9 ' 3 0 " E 9 8 . 6 8 ' N81 ° 5 0 ' 4 0 " W 43. 8 7 ' S7 1 ° 1 2 ' 2 0 " W 21 7 . 8 6 ' N 0 8 ° 0 9 ' 3 0 " E 1 3 7 . 6 5 ' N7 1 ° 4 9 ' 3 0 " E 33 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60' KI R K W O O D B O U L E V A R D STATE HIGHWAY 114 EX-PL EX-PL∆ ∆ ∆ 5 8 5 58 5 5 9 0 59 0 59 5 59 5 6 0 0 60 0 58 1 58 1 58 2 5 8 3 58 3 5 8 4 58 4 5 8 6 58 6 5 8 7 58 7 5 8 8 58 8 5 8 9 58 9 5 9 1 59 1 59 2 59 2 59 3 59 3 59 4 59 4 59 6 59 6 59 7 59 7 59 8 59 8 5 9 9 59 9 601 6 0 1 58 0 58 5 59 0 5 9 5 578 57 9 5 8 1 5 8 2 5 8 358 458 6 58 7 5 8 8 58 9 59 159 2 59 3 59 4 5 9 6 5 9 7 5 9 8 5 9 9 58 0 5 8 5 5 7 9 5 8 1 5 8 2 5 8 3 5 8 4 5 8 6 585 590 595 600 584 586 587 588 589 591 592 593 594 596 597 598 599 601 585 5 8 1 5 8 1 5 8 2 5 8 2 582 5 8 3 584 58 0 580 58 5 5 9 0 5 9 5 600 57 6 57 6 57 7 57 7 57 8 57 8 57 9 579 58 1 581 582 58 2 583 58 3 584 5 8 4 58 6 58 7 58 8 58 9 5 9 1 5 9 2 5 9 3 594 5 9 6 5 9 7 598 599 601 585 5 8 5 581 582 583 584 PROPOSED CURB INLET PROPOSED CURB INLET PROPOSED CURB INLET 5 9 5 5 9 4 5 9 3 59 2 590 589 588 5 8 9 5 9 0 5 9 0 5 8 9 588 586 589 58 8 5 8 8 58 4 587 591 592 5 9 2 5 9 1 59 4 593 592 587 5 8 7 586 5 8 7 5 8 8 5 8 8 589 58 8 58 7 58 6 58 5 58 4 5 8 8 58 6 RETAINING WALL RETAINING WALL RETAINING WALL C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 THESE PLANS ARE SUBJECT TO REVIEW & APPROVAL BY JURISDICTIONAL ENTITIES. Know what's below. before you dig.Call R GR A D I N G P L A N S5.0 GRA                     FI L E N A M E : S5 . 0 G R A D I N G P L A N . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D A T : 10 : 2 6 : 4 0 A M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n \ S 5 . 0 G R A D I N G P L A N GRA 2017.129 DWL LMG LEGEND FG=100.50 100 100 PROPOSED CONTOUR EXISTING CONTOUR FLOWLINE GRADE BREAK ACCESSIBLE ROUTE SPOT GRADE PROPOSED RETAINING WALL PROPOSED FLOW ARROW FG FINISHED GRADE TP TOP OF PAVEMENT TC TOP OF CURB FL FLOWLINE FF FINISHED FLOOR PROPOSED CURB INLET PROPOSED CENTER LINE OF STORM PIPE PRELIMINARY FOR REVIEW PURPOSES ONLY NTS SITE MAP PROJECT LOCATION CASE NO: ZA18-006 CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX GRAPHIC SCALE FEET08040 1"=40' PRO P O S E D CUR B I N L E T TP = 586.9 TP = 586.9 TP = 586.9 TP = 586.7 FH FH G A S G A S G A S G A S G A S GAS GAS GAS GAS GAS GAS GAS GAS GAS T P U E U E U E FH W SS SS W W W W W W W W W W SS SS 5 9 1 580 585 590 595 578 579 581 582 583 584 586 587 588 589 591 592 593 594 596 597 5 9 8 599 580 585 58 1 58 2 583 584 586 5 8 0 580 585 59 0 595 5 7 6 57 6 5 7 7 5 7 7 5 7 8 57 8 5 7 9 579 5 8 1 581 582 5 8 2 583 5 8 3 584 58 4 586 587 588 589 59 1 592 593 594 596 597 598 58 5 5 8 5 PORTE COCHERE LOT 1 105 , 5 8 7 S F (±2 . 4 2 2 A C ) FFE = 5 8 9 . 0 0 BLD G = 1 6 , 0 5 5 S F FI R E L A N E FIREL A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIR E L A N E FIRELANE FIRELANE FIRELANE FIRELANE FIRELANE FIRELANE FIRELANE FIRELANE FIR E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIRELANE F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E ∆ S3 8 ° 5 1 ' 1 0 " W 12 4 . 6 7 ' N5 1 ° 0 8 ' 5 0 " W 16 2 . 0 1 ' N5 1 ° 0 8 ' 5 0 " W 99 . 1 5 ' N08° 09' 30"E 98.68' N08° 09' 30"E 137.65' N 7 1 ° 4 9 ' 3 0 " E 3 3 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60 ' 58 8 589 590 5 9 0 589 5 8 8 588 58 7 58 7 58 6 5 8 7 5 8 8 5 8 8 589 588 5 8 7 5 8 6 5 8 5 5 8 4 5 8 6 TP = 585.5 TP = 587.2 TP = 587.3 TP = 587.6 TP = 587.8 TP = 587.8 TP = 587.3 TP = 587.1 TP = 587.2 TP = 587.7 TP = 587.9 TP = 588.2 TP = 588.8 TP = 588.6 TP = 589.8 TP = 590.1 TP = 590.2TP = 590.2TP = 590.1 TP = 588.6TP = 588.4TP = 588.7 TP = 588.0TP = 588.5 TP = 588.7 TP = 588.5 TP = 588.9TP = 588.2 TP = 587.6 TP = 587.8 TP = 588.0 TP = 587.4 TP = 587.6 TP = 587.2 TP = 586.6 TP = 587.0 TP = 586.5 TP = 586.0 TP = 586.0 TP = 587.6 TP = 588.0 TP = 588.0 TP = 587.6 TP = 588.0 TP = 588.5 TP = 588.7 TP = 588.7 TP = 588.0 TP = 588.7 TP = 588.5 TP = 588.0 TP = 587.8 TP = 584.0 TP = 584.0 TP = 587.6 TP = 588.0 TP = 584.0 TP = 585.0 TP = 587.6 TP = 588.0 TP = 588.8TP = 587.4TP = 586.8 C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 THESE PLANS ARE SUBJECT TO REVIEW & APPROVAL BY JURISDICTIONAL ENTITIES. Know what's below. before you dig.Call R GR A D I N G P L A N L O T 1 S5.1 DL                     FI L E N A M E : S5 . 1 G R A D I N G P L A N L O T 1 . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D A T : 10 : 2 7 : 3 3 A M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n \ S 5 . 1 G R A D I N G P L A N L O T 1 DL 2017.129 DL MP LEGEND FG=100.50 100 100 PROPOSED CONTOUR EXISTING CONTOUR FLOWLINE GRADE BREAK ACCESSIBLE ROUTE SPOT GRADE PROPOSED RETAINING WALL PROPOSED FLOW ARROW FG FINISHED GRADE TP TOP OF PAVEMENT TC TOP OF CURB FL FLOWLINE FF FINISHED FLOOR PROPOSED CURB INLET PROPOSED CENTER LINE OF STORM PIPE PRELIMINARY FOR REVIEW PURPOSES ONLY NTS SITE MAP PROJECT LOCATION CASE NO: ZA18-006 CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX GRAPHIC SCALE FEET04020 1"=20' KI R K W O O D B O U L E V A R D STATE HIGHWAY 114 EX-PL EX-PL 5 8 5 58 5 5 9 0 59 0 59 5 59 5 6 0 0 60 0 58 1 58 1 58 2 5 8 3 58 3 5 8 4 58 4 5 8 6 58 6 5 8 7 58 7 5 8 8 58 8 5 8 9 58 9 5 9 1 59 1 59 2 59 2 59 3 59 3 59 4 59 4 59 6 59 6 59 7 59 7 59 8 59 8 5 9 9 59 9 601 6 0 1 58 0 58 5 59 0 5 9 5 578 57 9 5 8 1 5 8 2 5 8 358 458 6 58 7 5 8 8 58 9 59 159 2 59 3 59 4 5 9 6 5 9 7 5 9 8 5 9 9 58 0 5 8 5 5 7 9 5 8 1 5 8 2 5 8 3 5 8 4 5 8 6 585 590 595 600 584 586 587 588 589 591 592 593 594 596 597 598 599 601 585 5 8 1 5 8 1 5 8 2 5 8 2 582 5 8 3 584 58 0 580 58 5 5 9 0 5 9 5 600 57 6 57 6 57 7 57 7 57 8 57 8 57 9 579 58 1 581 582 58 2 583 58 3 584 5 8 4 58 6 58 7 58 8 58 9 5 9 1 5 9 2 5 9 3 594 5 9 6 5 9 7 598 599 601 585 5 8 5 581 582 583 584 A-1 1.26 A-2 0.21 A-4 3.58 A-3 0.95 C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 THESE PLANS ARE SUBJECT TO REVIEW & APPROVAL BY JURISDICTIONAL ENTITIES. Know what's below. before you dig.Call R PR E - D E V E L O P E D DR A I N A G E A R E A M A P S5.2 DL                     FI L E N A M E : S5 . 2 P R E - D E V E L O P E D D R A I N A G E A R E A M A P . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D A T : 10 : 3 6 : 4 0 A M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n \ S 5 . 2 P R E - D E V E L O P E D D R A I N A G E A R E A M A P DL 2017.129 DL MP PRELIMINARY FOR REVIEW PURPOSES ONLY CASE NO: ZA18-006 NTS SITE MAP PROJECT LOCATION CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX GRAPHIC SCALE FEET08040 1"=40' LEGEND ACRES BASIN NAME DRAINAGE BASIN DRAINAGE AREA EXISTING FLOW ARROW DA-00 1.00 P O R T E C O C H E R E LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF LOT 2 51,029 SF (±1.169 AC) FFE = 596.00 BLDG = 5,000 SF LOT 3 50,465 SF (±1.160 AC) FFE = 596.00 BLDG = 5,000 SF LOT 4 37,979 SF (±.873 AC) FFE = 588.00 BLDG = 5,000 SF FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIR E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E FIR E L A N E ∆ S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S 3 8 ° 5 1 ' 1 0 " W 1 2 4 . 6 7 ' N51° 0 8 ' 5 0 " W 162.01 ' N51° 0 8 ' 5 0 " W 99.15' N 0 8 ° 0 9 ' 3 0 " E 9 8 . 6 8 ' N81 ° 5 0 ' 4 0 " W 43. 8 7 ' S7 1 ° 1 2 ' 2 0 " W 21 7 . 8 6 ' N 0 8 ° 0 9 ' 3 0 " E 1 3 7 . 6 5 ' N7 1 ° 4 9 ' 3 0 " E 33 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60' KI R K W O O D B O U L E V A R D STATE HIGHWAY 114 EX-PL EX-PL∆ ∆ ∆ 5 8 5 58 5 5 9 0 59 0 59 5 59 5 6 0 0 60 0 58 1 58 1 58 2 5 8 3 58 3 5 8 4 58 4 5 8 6 58 6 5 8 7 58 7 5 8 8 58 8 5 8 9 58 9 5 9 1 59 1 59 2 59 2 59 3 59 3 59 4 59 4 59 6 59 6 59 7 59 7 59 8 59 8 5 9 9 59 9 601 6 0 1 58 0 58 5 59 0 5 9 5 578 57 9 5 8 1 5 8 2 5 8 358 458 6 58 7 5 8 8 58 9 59 159 2 59 3 59 4 5 9 6 5 9 7 5 9 8 5 9 9 58 0 5 8 5 5 7 9 5 8 1 5 8 2 5 8 3 5 8 4 5 8 6 585 590 595 600 584 586 587 588 589 591 592 593 594 596 597 598 599 601 585 5 8 1 5 8 1 5 8 2 5 8 2 582 5 8 3 584 58 0 580 58 5 5 9 0 5 9 5 600 57 6 57 6 57 7 57 7 57 8 57 8 57 9 579 58 1 581 582 58 2 583 58 3 584 5 8 4 58 6 58 7 58 8 58 9 5 9 1 5 9 2 5 9 3 594 5 9 6 5 9 7 598 599 601 585 5 8 5 581 582 583 584 PROPOSED 15' CURB INLET PROPOSED 5' CURB INLET PROPOSED 5' CURB INLET RETAINING WALL RETAINING WALL RETAINING WALL C-2 0.21 A-2 0.36 A-1 0.23 C-1 1.47 D-1 0.35 B-1 1.83 E-1 0.55 E-2 1.00 PROPOSED 21" SET OUTFALL PROPOSED 21" RCP PROPOSED 21" SET OUTFALL PROPOSED 21" RCP PROPOSED 21" RCP C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 THESE PLANS ARE SUBJECT TO REVIEW & APPROVAL BY JURISDICTIONAL ENTITIES. Know what's below. before you dig.Call R PO S T - D E V E L O P E D DR A I N A G E A R E A M A P & DR A I N A G E P L A N S5.3 DL                     FI L E N A M E : S5 . 3 P O S T - D E V E L O P E D D R A I N A G E A R E A M A P & D R A I N A G E P L A N . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D A T : 10 : 3 7 : 1 8 A M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n \ S 5 . 3 P O S T - D E V E L O P E D D R A I N A G E A R E A M A P & D R A I N A G E P L A N DL 2017.129 DL MP PRELIMINARY FOR REVIEW PURPOSES ONLY NTS SITE MAP PROJECT LOCATION CASE NO: ZA18-006 CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX GRAPHIC SCALE FEET08040 1"=40' LEGEND DA-00 1.00ACRES BASIN NAME DRAINAGE BASIN DRAINAGE AREA PROPOSED FLOW ARROW STORM SEWER P O R T E C O C H E R E LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF LOT 2 51,029 SF (±1.169 AC) FFE = 596.00 BLDG = 5,000 SF LOT 3 50,465 SF (±1.160 AC) FFE = 596.00 BLDG = 5,000 SF LOT 4 37,979 SF (±.873 AC) FFE = 588.00 BLDG = 5,000 SF FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIR E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E FIR E L A N E ∆ S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S 3 8 ° 5 1 ' 1 0 " W 1 2 4 . 6 7 ' N51° 0 8 ' 5 0 " W 162.01 ' N51° 0 8 ' 5 0 " W 99.15' N 0 8 ° 0 9 ' 3 0 " E 9 8 . 6 8 ' N81 ° 5 0 ' 4 0 " W 43. 8 7 ' S7 1 ° 1 2 ' 2 0 " W 21 7 . 8 6 ' N 0 8 ° 0 9 ' 3 0 " E 1 3 7 . 6 5 ' N7 1 ° 4 9 ' 3 0 " E 33 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60' W W W W W W W W W W W FH FH FH FH SS SS SS SS GA S GA S GA S G A S G A S G A S G A S G A S GAS GAS T T T T P P FH FH FH FH SS SS SS SS SS SS SS S S W W W W W W W W W W W W S S KI R K W O O D B O U L E V A R D STATE HIGHWAY 114 EX-PL EX-PL TIE INTO EXISTING MANHOLE INSTALL DROP CONNECTION 18" E X . S A N . S E W E R 1 8 " E X . S A N . S E W E R CAP 14" WATER LINE W/ 2" BLOW-OFF VALVE 8" PUBLIC SS 14" WATER LINE PROPOSED FIRE HYDRANT ASSEMBLY PROPOSED FIRE HYDRANT ASSEMBLY EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT 1 2 " W A T E R L I N E TIE IN TO EXISTING 14" WATER LINE TIE IN TO EXISTING 6" GAS LINE @ TWKING PROPOSED 4'∅ MANHOLE PROPOSED 4'∅ MANHOLE PROPOSED 4'∅ MANHOLE TIE IN TO EXISTING 14" WATER LINE 6" W 1 2 " W A T E R L I N E 4" W 6 " W METER METERMETER METER PROPOSED FIRE HYDRANT ASSEMBLY 8" W A T E R L I N E PROPOSED FIRE HYDRANT ASSEMBLY PROPOSED FIRE HYDRANT ASSEMBLY PROPOSED FIRE HYDRANT ASSEMBLY 2 1 2 GREASE TRAP ELEC. TRANSFORMER ELEC. TRANSFORMER ELEC. TRANSFORMER GREASE TRAP GREASE TRAP ELEC. TRANSFORMER GREASE TRAP 14 " E X . W A T E R 14 " E X . W A T E R 14" WATER LINE PROPOSED 4'∅ MANHOLE PROPOSED 4'∅ MANHOLE 8" FIRE LINE FDC FDC 8" CAP W/ 2" BLOW-OFF VALVE 8" FIRE LINE FDC 6" FH LEAD PROPOSED 4'∅ MANHOLE 6" WATER LINE 8" FIRE LINE FDC 8" WAT E R L I N E 8" FIRE LINE 4" W6" W 4" W 4 " W 6 " W 6" W 1 1 1 8" PUB L I C S S 8 " P U B L I C S S 6" PRIVATE SS 8 " P U B L I C S S 8" PUB L I C S S 6" PRIVATE SS 6" PRIVATE SS 6" PRIVATE SS 8" PUBLIC SS C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 LEGEND PROPOSED UNDERGROUND ELECTRIC PROPOSED GAS PROPOSED SANITARY SEWER PROPOSED TELEPHONE PROPOSED WATER PROPOSED FIRE HYDRANT PROPOSED MANHOLE PROPOSED TRANSFORMER THESE PLANS ARE SUBJECT TO REVIEW & APPROVAL BY JURISDICTIONAL ENTITIES. Know what's below. before you dig.Call R PR E L I M I N A R Y UT I L I T Y P L A N S6.0 GRA                     FI L E N A M E : S6 . 0 P R E L I M I N A R Y U T I L I T Y P L A N . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D A T : 10 : 3 8 : 0 0 A M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n \ S 6 . 0 P R E L I M I N A R Y U T I L I T Y P L A N   2017.129 DWL LMG W FH T S S CASE NO: ZA18-006 LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TXPRELIMINARY FOR REVIEW PURPOSES ONLY WATER-SANITARY SEWER CROSSING PER CITY AND TCEQ STANDARDS. UTILITY CROSSINGS 1 SYMBOL KEY 2 NTS SITE MAP PROJECT LOCATION CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER / DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM GRAPHIC SCALE FEET08040 1"=40' NOTES: 1.MINIMUM SIZE FOR SANITARY SEWER IS 8". SANITARY SEWER SERVICE LINES SHALL CONNECT TO PUBLIC SANITARY SEWER SYSTEM BUILT TO CITY STANDARDS. 2.MINIMUM SIZE PUBLIC WATER MAIN IS 8". 3.PRIVATE SANITARY SEWER SERVICES NEED A PLUMBING PERMIT AND MUST BE INSPECTED BY BUILDING INSPECTIONS PRIOIR TO BURIAL. 4.FOR THE SPRINKLER SYSTEMS THE DOUBLE CHECK VALVES SHALL BE IN VAULTS. LOT 1 LOT 2 51,0 2 9 S F (±1. 1 6 9 A C ) FFE = 5 9 6 . 0 0 BLD G = P . B . A . 6 , 7 0 0 S F LOT 3 50,4 6 5 S F (±1. 1 6 0 A C ) FFE = 5 9 6 . 0 0 BLD G = P . B . A . 6 , 0 0 0 S F LOT 4 37,9 7 9 S F (±.8 7 3 A C ) FFE = 5 8 8 . 0 0 BLD G = P . B . A . 6 , 0 0 0 S F F I R E L A N E FIRELANE FI R E L A N E FI R E L A N E LOT 4 37,9 7 9 S F (±.8 7 3 A C ) FFE = 5 8 8 . 0 0 BLD G = 5 , 0 0 0 S F FI R E L A N E FI R E L A N E FI R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E S28 ° 0 7 ' 0 9 " W 119. 4 9 ' S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S3 8 ° 5 1 ' 1 0 " W 12 4 . 6 7 ' N5 1 ° 0 8 ' 5 0 " W 16 2 . 0 1 ' S3 7 ° 0 2 ' 5 7 " W 16 8 . 0 5 ' S 4 6 ° 3 3 ' 5 5 " W 1 2 0 . 1 0 ' S28 ° 0 7 ' 0 9 " W 119. 4 9 ' F I R E L A N E F I R E L A N E 10' BUFFERYARD TYPE 'B' LOT 3 F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E F I R E L A N E FI R E L A N E FIRELAN E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIREL A N E FIRELANE FIRELA N E FIR E L A N E FIRE L A N E F I R E L A N E FIRE L A N E FIREL A N E FIRELANE FI R E L A N E FIRELAN E FIRELANE U . P . M A R T I N S U R V E Y A B S T R A C T N O . 1 0 1 5 STA T E H I G H W A Y 1 1 4 (VA R I A B L E W I D T H P U B L I C R I G H T - O F - W A Y ) = 2 1 ° 1 0 ' 4 5 " R = 1 4 1 9 . 5 0 ' L = 5 2 4 . 7 1 ' C H = N 7 3 ° 1 8 ' 2 6 " E 5 2 1 . 7 3 ' ! D - 9 4 3 7 - 1 1 2 7 FI R E L A N E FIRELAN E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIREL A N E FIRELANE FIRELA N E Z O N E " X " U N S H A D E D 1 0 . d . 1 0 ' W A T E R E A S E M E N T C A B I N E T A , S L I D E 7 2 1 2 P . R . T . C . T . C O N C R E T E P A V I N G C O N C R E T E P A D 10' BUFFERYARD TYPE 'B' PORTE COCHERE LOT 1 105 , 5 8 7 S F (±2 . 4 2 2 A C ) FFE = 5 8 9 . 0 0 BLD G = 1 6 , 0 5 5 S F LOT 2 51,0 2 9 S F (±1 . 1 6 9 A C ) FFE = 5 9 6 . 0 0 BLD G = 5 , 0 0 0 S F LOT 3 50,4 6 5 S F (±1 . 1 6 0 A C ) FFE = 5 9 6 . 0 0 BLD G = 5 , 0 0 0 S F LOT 4 37,9 7 9 S F (±.8 7 3 A C ) FFE = 5 8 8 . 0 0 BLD G = 5 , 0 0 0 S F FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELANE FIRELANE FIRELANE FIRELANE FIRELANE FIREL A N E FI R E L A N E FI R E L A N E FIRELANE F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FIRELAN E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIREL A N E FIRELANE FIRELA N E FIR E L A N E FIRE L A N E F I R E L A N E FIRE L A N E FIREL A N E FIRELANE FI R E L A N E FIRELAN E FIRELANE S06°06'1 1 " E 7 1 . 0 5 ' S08°13'29"W 172.54'S06°31'52"W 182.88' S28 ° 0 7 ' 0 9 " W 119. 4 9 ' = 2 1 ° 1 0 ' 4 5 " R = 1 4 1 9 . 5 0 ' L = 5 2 4 . 7 1 ' C H = N 7 3 ° 1 8 ' 2 6 " E 5 2 1 . 7 3 ' K I R K W O O D B O U L E V A R D ( 1 3 1 ' W I D T H P U B L I C R I G H T - O F - W A Y ) C O N C R E T E P A V I N G C . C . D . N O D 2 1 5 2 3 2 7 5 1 D . R . T . C . T . STA T E H I G H W A Y 1 1 4 (VA R I A B L E W I D T H P U B L I C R I G H T - O F - W A Y ) CON C R E T E P A V I N G DIRE C T I O N A L CON T R O L L I N E N30° 0 8 ' 4 9 " W 232. 6 3 ' S3 7 ° 0 2 ' 5 7 " W 16 8 . 0 5 ' S 4 6 ° 3 3 ' 5 5 " W 1 2 0 . 1 0 ' S28 ° 0 7 ' 0 9 " W 119. 4 9 ' S06°31'52"W 182.88'S08°13'29"W 172.54' S06°06'1 1 " E 7 1 . 0 5 ' = 2 1 ° 1 0 ' 4 5 " R = 1 4 1 9 . 5 0 ' L = 5 2 4 . 7 1 ' C H = N 7 3 ° 1 8 ' 2 6 " E 5 2 1 . 7 3 ' EX-P L WM CO ! ! ! 17 8 5 D - 9 4 3 7 - 1 1 2 7 C & B C & B FI R E L A N E FIRELAN E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRE L A N E FIREL A N E FIRELANE FIRELA N E 1 0 . d . 1 0 ' W A T E R E A S E M E N T C A B I N E T A , S L I D E 7 2 1 2 P . R . T . C . T . 1 5 ' E L E C T R I C E A S E M E N T C A B I N E T A , S L I D E 7 2 1 2 P . R . T . C . T . C O N C R E T E P A V I N G C O N C R E T E P A D C O N C R E T E P A D 10' BUFFERYARD TYPE 'B' 10' BUFFERYARD TYPE 'B' 10' BUFFERYARD TYPE 'B' 10' BUFFERYARD TYPE 'B' THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF LANDSCAPE ARCHITECT No. 1826, ON ---- THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES BEN R. HENRY, ASLA SYM.KEY QTY.COMMON NAME SCIENTIFIC NAME SPREADHEIGHTSIZEROOTO.C.COMMENT Plant Material List City of Southlake, Texas Reference Recommended Plant Material List In Accordance to the Current Edition of The American Standard for Nursery Stock LA N D S C A P E P L A N LO T 1 S7.1 FI L E N A M E : S7 . 1 L A N D S C A P E P L A N L O T 1 . d w g PL O T T E D B Y : Ja m e s K i n d r e d PL O T T E D O N : Fr i d a y , M a r c h 1 6 , 2 0 1 8 PL O T T E D A T : 11 : 4 6 : 1 1 A M PL O T T E D W I T H : No n e FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n I : \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n \ S 7 . 1 L A N D S C A P E P L A N L O T 1 BRH 2017-129 JRK JRK 3.0 LANDSCAPE /IRRIGATION REQUIREMENTS 3.3 INTERIOR LANDSCAPE AREA REQUIREMENTS: The amount of landscape area required on the interior of the lot (excludes bufferyards) shall be on the square footage of the proposed buildings. The square footage of the building for the purpose of this ordinance will be the square footage of the first floor or the square footage of the largest floor, whichever is greater. a. Calculating Interior Landscape Area: The required landcape area for each zoning shall be based on the percentage (%) of the floor area as determined above in accordance with the following chart. ZONING C1, C2, C3, HC = 50% OF FLOOR AREA b. Planting requirements: The following plants shall be required, at a minimum within the required interior landscape areas at the ratio indicated. - 1 Canopy Tree per 500 square feet - 1 Understory Tree per 250 square feet - 1 Shrub per 40 square feet - Ground Cover - 15% of required area - Seasonal Color - 2% of required area 3.4 PARKING LOT LANDSCAPE REQUIREMENTS: The parking lot landscape area requirements shall be as follows based on the percentage of parking located between the building façade and the R.O.W.. Any new parking area added to an existing site shall comply with the requirements herein. Less than 25% = 15 sq. ft. per parking stall Each row of parking stalls shall provide the required landscape area, however, it shall be the applicant's right to place the islands near the buildings, throughout the parking, or at the end of the rows away from the building. The Landscape Administrator may modify the island requirement for each row in situations where it would appear beneficial to combine an awkward or hazardous island into a larger island within the parking area. Planter islands shall have a minimum width of 12' back-to-back if curbed or 13' edge-to-edge if no curb is intended, and shall be equal to the length of the parking stall. Parking lot landscape areas do count towards the total required interior landscape area. a. Existing Trees: The Landscape Administrator may approve variations to the parking lot landscape island requirements in order to preserve existing trees in interior parking areas. For existing trees the minimum width of the parking lot landscape island shall be as follows: Tree Size Min. Island Width Min. Dist. Tree to Curb 6" - 12" DBH = 12' minimum width 4’ Greater than 12" DBH = 18' minimum width 8’ b. Planting Requirements: Each individual parking lot landscape island shall contain a minimum of one (1) canopy tree with the remaining area in shrubs, ground cover, ornamental grasses, or seasonal color. Parking lot landscape islands which have light poles for lighting the parking areas may substitute two (2) understory/accent trees for the required canopy tree. All required landscape areas shall be evenly distributed throughout the entire required parking lot landscape areas. LANDSCAPE REQUIREMENTS for the City of Southlake, TX LANDSCAPE CALCULATIONS for the City of Southlake, TX REQUIRED Interior Landscape Area Requirements:First Floor = 16,055 SF x 50% = 8,028 SF Canopy Trees (1 per 500 SF)8,028 SF / 500 SF = 17 Trees Understory Trees (1 per 250 SF)8,028 SF / 250 SF = 33 Trees Shrubs (1 per 40 SF)8,028 SF / 40 SF = 201 Shrubs Ground Cover (15%)8,028 SF x 15% = 1,205 SF Seasonal Color (2%)8,028 SF x 2% = 161 SF LOT 1 PROPOSED SHRUB-296 N/A CONT.-- -N/A CONT.--- PROVIDED 33 Trees 201 Shrubs 1,205 SF 161 SF 17 Trees 8,028 SF PROPOSED GROUNDCOVER / SEASONAL COLOR 3 gal. min. Shrubs at parking adjacent to public R.O.W. must be 30" o.c. min. CASE NO:ZA18-006 LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TX GRAPHIC SCALE FEET06030 1"=30' CANOPY TREES: UNDERSTORY TREES: CE Cedar Elm Ulmus crassifolia N/A 4" cal.14' min.8' min. LO Live Oak Quercus virginiana N/A 4" cal.14' min.8' min. Full Canopy, Healthy, Good Form Full Canopy, Healthy, Good FormCont. Cont. 11 7 SO Shumard Oak Quercus shumardii N/A 4" cal.14' min.8' min.Full Canopy, Healthy, Good Form Strong Single Leader16Cont. CP Chinese Pistache Pistacia chinensis N/A Cont.4" cal.14' min.8' min.Healthy, Good Form Strong Single Leader6 RB Redbud Cersis canadensis N/A Cont.2" cal.10' min.5' min.Large Full Canopy, Healthy, Good Form Single Trunk19 Cont.2" cal.10' min.5' min.Full Canopy, Healthy, Good FormN/ACMCrape Myrtle 'Natchez' Lagerstroemia indica 'Natchez'Multi-trunk, Upright10 MP Mexican Plum Prunus mexicana Cont.2" cal.10' min.5' min.Full Canopy, Healthy, Good Form9N/A Eldarica (Afgan) Pine Pinus eldarica 2" cal.10' min.5' min.Full Canopy, Healthy, Good Form Strong Single Leader11EPN/A Cont. PH Possumhaw Holly Ilex verticillata Cont.2" cal.10' min.5' min.7 N/A Full Canopy, Healthy, Good Form 9,945 sf C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 2 0 1 4 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 D a l l a s , T e x a s 7 5 0 1 9 ( 8 1 7 ) 3 2 8 - 3 2 0 0 JUNE 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM SITE PLAN KEY MAP PRELIMINARY FOR REVIEW PURPOSES ONLY P O R T E C O C H E R E LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF LOT 2 51,029 SF (±1.169 AC) FFE = 596.00 BLDG = 5,000 SF LOT 3 50,465 SF (±1.160 AC) FFE = 596.00 BLDG = 5,000 SF LOT 4 37,979 SF (±.873 AC) FFE = 588.00 BLDG = 5,000 SF FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIR E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E FIR E L A N E ∆ S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S 3 8 ° 5 1 ' 1 0 " W 1 2 4 . 6 7 ' N51° 0 8 ' 5 0 " W 162.01 ' N51° 0 8 ' 5 0 " W 99.15' N 0 8 ° 0 9 ' 3 0 " E 9 8 . 6 8 ' N81 ° 5 0 ' 4 0 " W 43. 8 7 ' S7 1 ° 1 2 ' 2 0 " W 21 7 . 8 6 ' N 0 8 ° 0 9 ' 3 0 " E 1 3 7 . 6 5 ' N7 1 ° 4 9 ' 3 0 " E 33 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60' EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W FH FH FH FH SS SS SST T T T P P FH FH FH FH SS SS SS PEDESTRIAN ACCESS 4' CONCRETE SIDEWALK PEDESTRIAN ACCESS 4' CONCRETE SIDEWALK C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 PE D E S T R I A N A C C E S S & O P E N SP A C E M A N A G E M E N T P L A N S8.0 GRA                     FI L E N A M E : S8 . 0 P E D . A C C E S S & O P E N S P A C E M G M T . P L A N . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D A T : 10 : 3 8 : 3 9 A M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - p r o d u c t i o n \ S 8 . 0 P E D . A C C E S S & O P E N S P A C E M G M T . P L A N   2017.129 DWL LMG CASE NO: ZA18-006 CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TXPRELIMINARY FOR REVIEW PURPOSES ONLY ARTICLE V11 - PARK AND RECREATION DEDICATION REQUIREMENTS. SECTION 7.03-2 LAND DEDICATION REQUIREMENTS Non-Residential Developments: Although non-residential development does not generate residential occupancies per se, it does create environmental impacts which may negatively affect the living environment of the community. These impacts may be ameliorated or eliminated by providing park or open space areas which buffer adjoining land uses, prevent undue concentration of paved areas, allow for the reasonable dissipation of automotive exhaust fumes, provide natural buffers to the spread of fire or explosion, and provide separation of lighting, waste disposal, and noise by-products of non-residential operations and activities from adjacent residential areas. The City has therefore determined that non-residential developments must provide dedicated parks and/or reserved open space at a ratio of one (1) acre of park land for every fifty (50) non-residential gross acres of development or prorated portion thereof. GRAPHIC SCALE FEET08040 1"=40' PEDESTRIAN ACCESS ROUTE AS SHOWN ALONG 6' WIDE SIDEWALKS PEDESTRIAN ACCESS LANDSCAPE REQUIREMENT FOR THE CITY OF SOUTHLAKE KI R K W O O D B O U L E V A R D STATE HIGHWAY 114 EX-PL EX-PL P O R T E C O C H E R E LOT 1 105,587 SF (±2.422 AC) FFE = 589.00 BLDG = 16,055 SF LOT 2 51,029 SF (±1.169 AC) FFE = 596.00 BLDG = 5,000 SF LOT 3 50,465 SF (±1.160 AC) FFE = 596.00 BLDG = 5,000 SF LOT 4 37,979 SF (±.873 AC) FFE = 588.00 BLDG = 5,000 SF FIRE L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FI R E L A N E FIR E L A N E FIR E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E F I R E L A N E FIRELA N E F I R E L A N E FIR E L A N E S 5 6 ° 0 0 ' 4 0 " W 8 2 . 6 5 ' S 3 8 ° 5 1 ' 1 0 " W 1 2 4 . 6 7 ' N51° 0 8 ' 5 0 " W 162.01 ' N51° 0 8 ' 5 0 " W 99.15' N 0 8 ° 0 9 ' 3 0 " E 9 8 . 6 8 ' N81 ° 5 0 ' 4 0 " W 43. 8 7 ' S7 1 ° 1 2 ' 2 0 " W 21 7 . 8 6 ' N 0 8 ° 0 9 ' 3 0 " E 1 3 7 . 6 5 ' N7 1 ° 4 9 ' 3 0 " E 33 . 1 0 ' N15° 1 5 ' 1 0 " W 59.60' EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W EX - 1 2 ' ' W FH FH FH FH SS SS SST T T T P P FH FH FH FH SS SS SS LEGEND C DRAWN BY: SHEET: JOB NUMBER: CHECKED BY: DESIGNED BY: Copyright 2018, Adams DATE: RE V I S I O N S DA T E T h i s d r a w i n g w a s p r e p a r e d b y A d a m s C o n s u l t i n g E n g i n e e r s , I n c . (A d a m s ) a s a n i n s t r u m e n t o f s e r v i c e , a n d s h a l l r e m a i n t h e p r o p e r t y o f A d a m s . T h e i n f o r m a t i o n h e r e o n s h a l l b e u s e d o n l y b y t h e c l i e n t t o w h o m t h e s e r v i c e s a r e r e n d e r e d a n d o n l y f o r t h e p u r p o s e o f c o n s t r u c t i n g o r i n s t a l l i n g t h e w o r k a s s h o w n a t t h e d e s i g n a t e d l o c a t i o n a n d s i t e . A n y o t h e r u s e , i n c l u d i n g (w i t h o u t l i m i t a t i o n ) a n y r e p r o d u c t i o n o r a l t e r a t i o n , i s s t r i c t l y p r o h i b i t e d , a n d t h e u s e r s h a l l h o l d h a r m l e s s a n d i n d e m n i f y A d a m s f r o m a l l l i a b i l i t i e s w h i c h m a y a r i s e f r o m s u c h u n a u t h o r i z e d u s e . C Co p y r i g h t 20 1 8 , A d a m s 89 5 1 C y p r e s s W a t e r s B l v d , S t e . 1 5 0 ■ D a l l a s , T e x a s 7 5 0 1 9 ■ ( 8 1 7 ) 3 2 8 - 3 2 0 0 MAY 2018 SO U T H W E S T M E A D O W S SO U T H L A K E , T E X A S THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW, AGENCY APPROVAL, AND COMMENT UNDER THE AUTHORITY OF G. ROBERT ADAMS, P.E. REGISTRATION No. 86184, ON 06/06/18 THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES TBPE Registration #: F-1002 CO N S T R U C T I O N PH A S E 1 P L A N S9.0 GRA                     FI L E N A M E : S9 . 0 C O N S T R U C T I O N P H A S E 1 P L A N . d w g PL O T T E D B Y : Mi k e P e t e r s o n PL O T T E D O N : We d n e s d a y , J u n e 0 6 , 2 0 1 8 PL O T T E D A T : 3: 5 4 : 1 4 P M PL O T T E D W I T H : PD F - X C h a n g e F o r A c r o P l o t P r o . p c 3 FU L L P A T H : I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n I: \ P r o j e c t s \ 2 0 1 7 \ 2 0 1 7 . 1 2 9 W i l k s D e v e l o p m e n t - K i r k w o o d S o u t h l a k e H o t e l \ D r a w i n g s \ 0 3 - P r o d u c t i o n \ S 9 . 0 C O N S T R U C T I O N P H A S E 1 P L A N   2017.129 DWL LMG CASE NO: ZA18-006 CIVIL ENGINEER : ADAMS - ENGINEERING/DEVELOPMENT CONSULTANTS 8951 CYPRESS WATER BLVD. SUITE 150 DALLAS, TX 75019 CONTACT: ROBERT ADAMS, P.E. PHONE: (817) 328-3200 EMAIL: ROB.ADAMS@ADAMS-ENGINEERING.COM OWNER/DEVELOPER WILKS SOUTHLAKE DEVELOPMENT, LLC 17018 I-20. CISCO, TX 76437 CONTACT: JOSH WILKS PHONE: 254-488-0600 EMAIL: JOSH.WILKS@WILKSDEVELOPMENT.COM APPLICANT / ARCHITECT : HODGES ASSOCIATES 13642 OMEGA DALLAS, TX 75244 CONTACT: CHARLES HODGES, AIA PHONE: 972-387-1000 EMAIL: CHODGES@HODGESUSA.COM NTS SITE MAP PROJECT LOCATION LOT 1R1R2, BLOCK 1 SABRE GROUP CAMPUS ADDITION AN ADDITION TO THE CITY OF SOUTHLAKE, ACCORDING TO THE PLAT RECORDED IN THE COUNTY CLERK'S DOCUMENT NUMBER D215221562, PLAT RECORDS, TARRANT COUNTY, TXPRELIMINARY FOR REVIEW PURPOSES ONLY PROPOSED FACE AND BACK OF CURB PROPOSED VEHICULAR PAVEMENT PROPOSED SIDEWALK OPEN SPACE PROPOSED RETAINING WALL CONSTRUCTION PHASE 1 BOUNDARY PROPOSED SANITARY MANHOLE PROPOSED CURB INLET PERMISSIBLE BUILDING AREA S S GRAPHIC SCALE FEET08040 1"=40' PHASE 1 = 3.31 ACRES PARKING TOTAL = 144 SPACES