Item 7B
Zoning Change and Site Plan for White Line Self Storage
ZA17-080
1
APPLICANT: DeOtte, Inc.
OWNER: White Line Partners, LLC
REQUEST: Approval of a Zoning Change and Site Plan from “AG” to “S-P-1” for the development of an approximately 90,275 square
foot three-story self storage facility.
LOCATION: 750 Davis Blvd. & 2360 Michael Dr.
ZA17-080
DeOtte, Inc. on behalf of White Line Partners, LLC is requesting approval of a Zoning Change and Site Plan for the development of an approximately 90,275 square foot three-story self
storage facility on property located at 750 Davis Blvd. and 2360 Michael Dr., Southlake, Texas. The Current Zoning is “AG” Agricultural District and the Proposed Zoning is “S-P-1” Detailed
Site Plan District.
2
Mixed Use
Mixed Use
Medium Density
Residential
Industrial
Low Density
Residential
Mixed Use
3
S-P-1
TZD
RE
SF-1A
I-1
AG
AG
SF-1A
I-1
I-1
I-1
I-1
SF-20A
4
Aerial
Davis Blvd (FM 1938)
Greenbriar Dr
Siena
Addition
Michael Dr
Villas at Hidden Knolls
The proposed development is located on the northwest corner of Davis Boulevard and Michael Drive (a private drive).
5
Proposed Site Plan
The purpose of the request is to gain approval of a zoning change from “AG” Agricultural District to “S-P-1” Detailed Site Plan District for the development of an approximately 90,275
square foot three-story self-storage building. The development will add twenty-two (22) standard parking spaces and six (6) loading spaces. All vehicular access will be from Michael
Drive, which is proposed to be improved to a 24-foot concrete drive as shown. A 5 foot sidewalk will be installed along the east boundary (Davis Blvd.)
6
Site Data
This slide shows the site data regarding the proposed development. The table on the bottom right compares the proposed regulations with what would be allowed under I-1 light industrial
zoning.
7
S-P-1 Proposed Permitted Uses
This property shall be limited to only the following permitted uses found in the “I-1” Light Industrial District, as described in Section 26 of the Comprehensive Zoning Ordinance No.
480, as amended:
1. Any use permitted in the O-1 Office district;
2. Cold storage warehouse without size limitation;
3. Mini-warehouses;
4. Warehouses.
8
Proposed S-P-1 Development Regulations
Development Regulations:
This property shall be subject to the normal development regulations contained within the respective Land Use Districts regulating Permitted Uses listed on
the previous slide, and all other applicable regulations, with the following exceptions:
At least one-third of the required off-street loading spaces or truck berths shall have a
minimum dimension of 10 feet by 50 feet each and the remaining required spaces or berths shall have a minimum dimension of 10 feet by 25 feet each - exclusive of turnaround and maneuvering
space.
Height: No building or structure which lies within sixty (60) feet of any area zoned in a residential classification shall exceed one (1) story or twenty (20) feet in height;
buildings lying more than sixty (60) feet from any area zoned in a residential classification shall not exceed three (3) stories or forty (40) feet in height.
Lot Area: The minimum
land area within a contiguous district boundary shall be two (2) acres. There shall be no minimum lot size for lots platted within this district.
Parking Requirement: Storage Uses:
One (1) off-street parking space required per 5,000 square feet of under-roof storage facility total area.
No building may encroach in the area above a line having a slope of 2.4:1
from any single-family property.
Building elevations and articulation allowed as submitted.
*Read the slide
Permitted Uses:
This property shall be limited to only the following permitted uses found in the “I-1” Light Industrial District, as described in Section 26 of the
Comprehensive Zoning Ordinance No. 480, as amended:
1. Any use permitted in the O-1 Office district;
2. Cold storage warehouse without size limitation;
3. Mini-warehouses;
4. Warehouses.
9
North & South Elevations
* Zoning regulation proposed for articulation as shown.
The applicant has written a zoning regulation allowing for articulation as presented. The north and south elevations have horizontal articulation that exceeds 3x predominant wall height
of 21’ (max 63’) shown on this slide in orange; wall runs at 90’ and 70’ respectively.
10
East Elevation
Here is a rendering showing the east elevation, or front of the building, which will face Davis Blvd. The building materials include cement stucco, king brick veneer, split face block,
prefinished projected metal fascia and frosted glazing on the window areas.
11
West Elevation
This is the west elevation
12
4:1 residential adjacency Slope requirement
The following slide is being shown for illustrative purposes regarding the 4:1 slope setback requirement for residential adjacency. The applicant is proposing a 2.4:1 setback rather
than 4:1.
13
Tree Preservation
There is an existing 36” Post Oak tree on the site which provides for approximately 2.45% tree canopy cover. The applicant has indicated they will preserve this existing tree, therefore
providing 100% tree preservation.
14
Landscape Plan
The proposed landscape plan… all interior landscape and bufferyard requirements are being met
15
Fencing
An 8 foot masonry wall is proposed on the north boundary and an 8 foot opaque (wood) fence is proposed on the west boundary.
16
Variances
Driveway Stacking Depth
28-Feet required
23-feet 2-inches
16-feet 5-inches
Drive ‘A’
Drive ‘B’
Minimum Spacing from Driveway Centerline
to intersecting ROW Line
100-Feet required
± 72 feet
There are two variances associated with the request. The applicant is subject to a 28-foot stacking depth requirement and has provided the following depths as shown. The applicant is
also subject to a minimum 100 foot spacing from the intersecting right of way to the centerline of the driveway; the site plan shows an approximate measurement of 72 feet.
17
Utility plan
Sewer
Water
Michael Dr.
The applicant will also be installing 8-inch sewer line to the existing 15-inch trunk line located to the west and an 8-inch water line to the existing 6-inch line along Davis Boulevard.
Michael Drive, which is a private street, will be constructed to City standards to a width of 24-feet but will not be accepted as a public street.
18
Site Photos
Looking west from Davis Blvd.
Looking north from Michael Dr.
19
Site Photos
Looking east towards Davis Blvd.
Looking north from Michael Dr.
20
P & Z Commission Action
October 19, 2017; Approved (6-0) as presented, subject to the Staff Report dated October 13, 2017 and the Site Plan Review Summary No. 2 dated October 11, 2017; specifically granting
requested variances to the Driveway Ordinance (regarding stacking depth and spacing).
21
Questions?
22