STAFF REPORT
October 31, 2017
CASE NO: ZA17-065
PROJECT: Barger & Associates Office Building
EXECUTIVE
SUMMARY:
REQUEST
DETAILS:
SITE DATA:
Case No.
ZA17-065
Barger & Associates Allstate is requesting approval of a Site Plan for an
approximately 3,025 square foot office building on property described as Lot 3,
T. Mahan No. 1049 Addition, City of Southlake, Tarrant County, Texas and
located at 440 N. Kimball Avenue, Southlake, Texas. Current Zoning: "I-1" Light
Industrial District. SPIN Neighborhood #4.
The subject property is generally located on the west side of N. Kimball
Avenue, approximately 375 feet north of the intersection of N. Kimball Avenue
and the westbound SH 114 Frontage Road.
The purpose of this request is for approval of a Site Plan for the development of
an approximately 3,025 square foot single -story office building to be occupied
by an Allstate Insurance Agency. The proposed development is consistent with
a previously approved concept plan under City case ZA13-089 which was
approved November 5, 2013 along with a site plan for Trinity Partners
Commercial Real Estate on the adjacent lot to the north (Lot 4).
Lot 3
. .•
Number of lots
1
1
Land Use Designation
Mixed Use
Mixed Use
Existing Zoning
1-1 Light Industrial
1-1 Light Industrial
Proposed Use
General Office
General Office
Gross Acreage
15,498 sf
17,222 sf
Building Area
3,025 sf
3,212 sf
Open Space %
41%
38%
Impervious Coverage %
59%
62%
Lots 3 and 4 share parking; the total square footage for both buildings is 5,237:
26 spaces are required; 27 spaces are provided
VARIANCES
REQUESTED: The following variances are being requested in relation to the proposed
development:
Reaulatinn Rec
Zoning Ordinance No. 480, Section 43.19.d (d)
Exposed Columns: Exposed structural support
There are proposed metal
columns shall be constructed of, or clad in, the
support brackets and metal
same masonry material as the principal structure.
columns shown on all four
Architecturally significant columns (e.g. fluted, etc.)
elevations of the building.
may be permitted.
Zoning Ordinance No. 480, Section 42.7.a Required
The applicant is requesting
Structures, Fences: An F1 bufferyard requires an 8'
relief from this requirement
opaque fence meeting the material requirements in
stating a fence would look out
Section 39.2b.
of place at this location.
The following are previously approved variances regarding the two -lot
development:
1. Tree Preservation Ordinance No. 585, as amended, requires at least 70%
minimum existing tree cover be preserved. There is a single 24" Oak tree
shown in the future connecting driveway extending through Lot 3. The tree
will remain until which time Lot 3 is constructed.
2. A reduction in the length of the required bufferyards to accommodate
intersecting drives and parking lot landscape islands, as shown on the plan.
3. A minimum spacing of 250 feet is required along N. Kimball Avenue. An
existing drive to the south is approximately 198.5 feet from the proposed
drive. An existing drive approach to the north is approximately 120 feet from
the proposed drive and does not currently serve an established use.
ACTION NEEDED: 1. Conduct a public hearing
2. Consider approval of a Site Plan
ATTACHMENTS: (A) Background Information
(B) Vicinity Map
(C) Revised Site Plan Review Summary No. 3, dated October 12, 2017
(D) Surrounding Property Owners Map & Responses
Full Size Plans (for Commission and Council Members Only)
Link to PowerPoint Presentation
Link to Narrative
Link to Plans
STAFF CONTACT: Dennis Killough (817) 748-8072
Lorrie Fletcher (817) 748-8069
Case No.
ZA17-065
BACKGROUND INFORMATION
OWNER/APPLICANT: Barger Equity Group, LLC
PROPERTY SITUATION: 440 N. Kimball Avenue
LEGAL DESCRIPTION: Lot 3, T. Mahan Survey No. 1049 Addition
LAND USE CATEGORY: Mixed Use
CURRENT ZONING: "I-1" Light Industrial District
HISTORY: The current 1-1 zoning was placed on the property with the adoption of
the Zoning Map in 1989.
November 5, 2013; City Council approved a site plan for Trinity Partners
Professional Office Building on Lot 4 that included a concept plan for Lot
3. (ZA13-089)
December 2, 2014; City Council approved a site plan for Trinity Partners
Professional Office Building on Lot 4 that modified the originally
approved building materials. (ZA14-136)
SOUTHLAKE 2030 PLAN: Consolidated Land Use Plan
Under the Southlake 2030 Consolidated
Land Use Plan the subject property isF
designated as Mixed Use. The subject
property has been designated as MixedUse since 1993. Typically, the Mixed Use
designation is intended for medium- to
higher -intensity office buildings, hotels,�21�°
i -T
commercial activities, retail centers, and
residential uses. Nuisance -free, wholly
enclosed light manufacturing and assembly uses that have no outdoor
storage are permitted if designed to be compatible with adjacent uses.
Mobility Master Plan
North Kimball Avenue in this location is classified as an "88' A4D," or a
4 -lane divided arterial with 88' of right of way. Turn lanes may be
necessary at key intersections and the design speed is 35-40 mph.
Typically no on -street parking is permitted.
There is an existing 6 foot sidewalk on the east boundary along N.
Kimball Avenue.
TRANSPORTATION
ASSESSMENT: Area Road Network and Conditions
* Based on the 2015 City of Southla/ce Traffic Count Report
Case No. Attachment A
ZA17-065 Page 1
Traffic Impact
General Office Building (710) 1 3,025 1 35 5 4 1 4
* Vehicle Trips Per Day
* AM -In, AM -Out, PM -In and PM -Out are peak hour generators on a weekday
* Based on the ITE.- Trip Generation Manual, 7`h Edition
TREE PRESERVATION: There is one (1) existing 24" Post Oak located within the parking lot area
of the proposed development. A variance to the canopy cover
preservation regulations of the Tree Preservation Ordinance was
approved with the Concept Plan approval and the proposed Site Plan is
the same.
PLANNING & ZONING
COMMISSION: October 19, 2017; Approved (6-0) as presented and subject to the Staff
Report dated October 13, 2017 and the Revised Site Plan Review
Summary No. 3, dated October 12, 2017; specifically granting the two
(2) variances in the staff report related to the columns and masonry
material and the required fencing (along the southern property line as
required in the 10' F-1 Bufferyard).
STAFF COMMENTS: Attached is Revised Site Plan Review Summary No. 3, dated October
12, 2017.
VARIANCE CRITERIA: Section 42 — Bufferyards
42.15 VARIANCES - The responsibility for granting variances shall be
as follows:
a. City Council: On all site plans and concept plans requiring review by
the Planning and Zoning Commission and approval by the City
Council, variances to the bufferyards may be granted by the City
Council.
Section 43 — Overlay Zones
c. Variances - At the time of review of any required Concept Plan or Site
Plan, the City Council may grant variances to the development
regulations set forth in this Section and to Section 35.6, "Number of Off -
Street Parking Spaces Required." A parking space variance can only be
granted at the request of the Owner/Applicant and cannot be required
by the City Council as a part of their approval of any Concept Plan, Site
Plan, Developer's Agreement or by any other means. The City Council
shall be limited to granting a variance to no more than fifteen percent
(15%) of the required number of off-street parking spaces.
1. To receive a variance, the applicant must demonstrate one of the
following:
(a) A variance will reduce the impact of the project on surrounding
residential properties; or
(b) Compliance with this ordinance would impair the architectural
design or creativity of the project; or
(c) A variance is necessary to assure compatibility with surrounding
developed properties; or
(d) The proposed construction is an addition to an existing project
Case No. Attachment A
ZA17-065 Page 2
that does not meet the requirements of this ordinance.
4. The City Council may grant a variance by an affirmative vote of a
majority of the City Council members present and voting on the matter.
In order to grant a variance, the City Council must determine that a
literal enforcement of the regulations will create an unnecessary
hardship or a practical difficulty for the applicant; that the situation
causing the unnecessary hardship or practical difficulty is unique to the
affected property; that the variance will not injure and will be wholly
compatible with the use and permitted development of adjacent
properties; and that the granting of the variance will be in harmony with
the spirit and purpose of this ordinance.
5. If a variance application is denied by the City Council, no other
variance of like kind relating to the same project or proposed project
shall be considered or acted upon by the City Council for a period of six
(6) months subsequent to the denial.
Case No. Attachment A
ZA17-065 Page 3
Vicinity Map
440 N. Kimball Avenue
L,
CD
C� a LO
00 LO
Nr
0, u, 2108
3
o
co
2112 0
CD 414
L
2104 ,�� ,
CO
Q
cv
v 00
COCO
2100 2102
211$ 210
2150
2354
114
ZA'17-065
5
Site Plan
r'r 0 300 600 1,.200
Feet
Case No. Attachment B
ZA17-065 Page 1
REVISED SITE PLAN REVIEW SUMMARY
Case No.: ZA17-065 Review No.: Three Date of Review: 10/12/17
Project Name: Site Plan — Lot 3, T. Mahan No. 1049 Addition — Barger & Associates Allstate
APPLICANT: Barger & Associates, LLC
Josh Barger
1330 N. White Chapel Blvd., Ste 400
Southlake, Texas 76092
Phone: 214-549-2713
Email: joshbarger@allstate.com
ARCHITECT:
Phone:
Email:
CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 10/10/17 AND WE
OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN
APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED
FURTHER CLARIFICATION, PLEASE CONTACT THE APPROPRIATE STAFF MEMBER.
Planning Review
Lorrie Fletcher
Planner
Phone: (817) 748-8069
Emai1:lfletcher ci.south lake. tx.us
1. Non -Residential Overlay:
a. Exposed Columns: Exposed structural support columns shall be constructed of, or
clad in, the same masonry material as the principal structure. Architecturally significant
columns (e.g. fluted, etc.) may be permitted. This regulation applies to the proposed
metal support brackets and the metal columns shown on all four elevations of the
building. A variance has been requested.
Tree Conservation/Landscape Review
Keith Martin
Landscape Administrator
Phone: (817) 748-8229
E-mail: kmartin(a)ci.south lake.tx.us
TREE PRESERVATION COMMENTS:
1. There is one (1) existing 24" Post Oak located within the parking lot area of the proposed
development. A variance to the canopy cover preservation regulations of the Tree
Preservation Ordinance was approved with the Concept Plan approval and the proposed Site
Plan is the same.
LANDSCAPE COMMENTS:
The south 10' — F1 bufferyard requires that the minimum of 6' stockade fence be constructed
along the property line. A variance has been requested.
Indicates informational comment.
Case No. Attachment C
ZA17-065 Page 1
# Indicates required items comment.
Public Works/Engineering Review
Steven Anderson, P.E.
Deputy City Engineer
Phone: (817) 748-8101
E-mail: sanderson(d�ci.southlake.tx.us
GENERAL COMMENTS:
This review is preliminary. Additional requirements may be necessary with the review of civil
construction plans.
New Requirement: Provide Stormwater Pollution Prevention Plan per TXR150000. The plan must
include all required elements in Part III, Section F of the permit. The City of Southlake
especially reviews Part III, Section F, (1) (g), Maps. The review is for completeness of a plan
to prevent pollution (especially sediment) to the Separate Storm Sewer System. It is highly
recommended the project manager provide a series of maps for complex projects, including
one map showing controls during mass grading and infrastructure, one map showing controls
during vertical construction, and one map showing final stabilization (may be but not always
equitable to the landscape plan). Please include timelines in relation to the project activities for
installation and removal of controls. SWPPP shall be submitted by second review of the
civil construction plans.
NEW REQUIREMENT: Submit with Civil Construction Plans a Retaining Wall Layout sheet, if
applicable.
Retaining walls greater than 4 -feet including the footing shall require structural plans prepared
by a registered engineer in the State of Texas. Retaining walls shall require a permit from the
Building Inspections Department prior to construction.
Street intersections shall comply with TDLR/ADA accessibility standards.
Sight distances shall comply with AASHTO guidelines on adjacent collectors and arterials.
Sidewalk widths shall conform to the Southlake Pathways Plan.
Use the City of Southlake GPS monuments whenever possible. Monument locations can be
found in the City of Southlake website:
http://www.citVofsouthlake.com/index.aspx?NID=266
EASEMENTS:
1. Provide all necessary easements for water, sanitary sewer and drainage. Easements shall be
15' minimum and located on one lot — not centered on the property line. A 20' easement is
required if both storm sewer and sanitary sewer will be located within the easement.
A drainage easement shall be required for the detention pond/s.
Case No.
ZA17-065
Attachment C
Page 2
Water and sanitary sewer cannot cross property lines without being in an easement or right of
way. All waterlines, sanitary sewer and storm sewer in easements or right of ways must be
constructed to City standards.
WATER COMMENTS:
1. Minimum size for water lines is 8".
Commercial and industrial developments require fire hydrant spacing of 300' maximum for
non -sprinkled buildings or 600' for sprinkled buildings.
Minimum water tap/meter size is 1"
Water lines cannot cross property lines without being in an easement or right of way.
The size of the water service tap must match the size of the meter. There are no reducers
allowed before the meter on the public side. A one inch meter must have a one inch tap, etc.
Water meters and fire hydrants shall be located in an easement or right of way.
Fire lines shall be separate from service lines.
SANITARY SEWER COMMENTS:
1. Minimum size for sanitary sewer is 8". Sanitary sewer service lines shall connect to public
sanitary sewer system built to City standards.
2. Add a note: Private sanitary sewer services need a plumbing permit and must be inspected by
building inspections prior to burial.
Sanitary sewer in easements or right of way shall be constructed to City standards.
DRAINAGE COMMENTS:
Calculations will be required to verify capacity of proposed curb inlets.
Storm sewers collecting runoff from public streets shall be RCP and constructed to City
standards.
Discharge of post development runoff must have no adverse impact on downstream properties
and meet the provisions of Ordinance No. 605.
INFORMATIONAL COMMENTS:
Submit 22"x34" civil construction plans and a completed Construction Plan Checklist directly to
the Public Works Administration Department for review. Please allow 15 business days for
review. The plans shall conform to the most recent construction plan checklist, standard
details and general notes which are located on the City's website:
http://www.cityofsouthlake.com/PublicWorks/engineeringdesign.asp
Submit with Civil Construction Plans a Storm Water Pollution Prevention Plan which outlines
pre -construction, construction and post -construction erosion control measures.
A Developer Agreement may be required for this development and may need to be approved
by the City Council prior to any construction of public infrastructure. Construction plans for
these improvements must be acceptable to Public Works prior to placing the Developer's
Agreement on the City Council agenda for consideration.
Case No. Attachment C
ZA17-065 Page 3
Any hazardous waste being discharged must be pretreated per Ordinance No. 836.
*=Denotes informational comment.
Fire Department Review
Kelly Clements
Fire Marshal
Phone: (817) 748-8233
E-mail: kclements ccDci.southlake.tx.us
No comments based on the submitted information.
Informational Comments:
* Staff strongly recommends contacting Jerod Potts to determine if a SPIN meeting would be
beneficial to your application. Jerod can be contacted by phone at (817) 748-8195 or by e-mail
at jpottsC@ci.southlake.tx.us. For more information about SPIN and the SPIN process please
go to https://www.citVofsouthlake.com/825/SPIN .
* No review of proposed signs is intended with this site plan. A separate building permit is
required prior to construction of any signs.
* All mechanical equipment must be screened of view right-of-ways and residential properties in
accordance with the Zoning Ordinance No. 480, as amended.
* All lighting must comply with the Lighting Ordinance No. 693, as amended.
* All development must comply with the Drainage Ordinance No. 605 and the Erosion and
Sediment Control Ordinance No. 946, as amended.
* It appears that this property lies within the 65 LDN D/FW Regional Airport Overlay Zone and
will require construction standards that meet requirements of the Airport Compatible Land Use
Zoning Ordinance No. 479.
* Through the wholesale water customer contract with the City of Fort Worth, all new water
connections are required to pay the City of Fort Worth impact fee. The City of Fort Worth
impact fee assessment is based on the final plat recordation date and building permit
issuance. The applicant is encouraged to review the City of Fort Worth's assessment and
collection of Impact Fees Guide to determine the fee amount.
* Development must comply with all requirements in Zoning Ordinance No. 480, Section 43,
Non -Residential Development Overlay Zone and Section 26, 1-1 — Light Industrial District.
* Masonry materials shall mean and include brick, stucco, plaster, cement, concrete tilt wall,
stone, rock or other masonry material of equal characteristics. Stucco and plaster shall only be
considered a masonry material when applied using a 3 -step process over diamond metal lath
Case No. Attachment C
ZA17-065 Page 4
mesh to a 7/8th inch thickness or by other processes producing comparable cement stucco
finish with equal or greater strength and durability specifications. Synthetic products (e.g.,
EIFS —exterior insulation and finish systems, hardi plank, or other materials of similar
characteristics) shall not be considered a masonry material.
Development must comply with all requirements in Zoning Ordinance No. 480, Section 33.21,
Building Color Standards for Non -Residential Buildings.
Staff recommends providing a materials sample board.
The applicant should be aware that prior to issuance of a building permit a Plat must be
processed and filed in the County Plat Records, a fully corrected site plan, landscape plan,
irrigation plan, and building plans, must be submitted for approval and all required fees must
be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street
Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees.
Denotes Informational Comment
Case No. Attachment C
ZA17-065 Page 5
Surrounding Property Owners
Responses: F: In Favor
Notices Sent:
Responses Received:
Case No.
ZA17-065
O: Opposed To U: Undecided
Ten (10)
Two (2) in favor
NR: No Response
Attachment D
Page 1
Owner
Zoning
Address
Acreage
Response
1
TATE, JOHN T
SP2
2120 E SH 114
0.92
NR
2
MAYSE, RICHARD A
SP2
2118 E SH 114
0.75
NR
3
SANDCO HOLDINGS LP
SP2
420 N KIMBALL AVE
0.54
NR
4
TEXAS PETRO CORP III
SP2
2150 E SH 114
1.16
NR
5
BOWEN SL LTD
11
450 N KIMBALL AVE
0.37
F
6
BARGER EQUITY GROUP
11
440 N KIMBALL AVE
0.32
NR
7
HAGAR, STEPHEN T
AG
479 N KIMBALL AVE
3.80
F
8
CHAMATHIL, VARGHESE
AG
411 N KIMBALL AVE
1.62
NR
9
MDP SOUTHLAKE LLC
SP2
2114 E SH 114
2.97
NR
10
MDP SOUTHLAKE LLC
SP2
2116 E SH 114
0.92
NR
11
KP SOUTHLAKE JV LLC
SP2
2112 E SH 114
1.30
NR
Responses: F: In Favor
Notices Sent:
Responses Received:
Case No.
ZA17-065
O: Opposed To U: Undecided
Ten (10)
Two (2) in favor
NR: No Response
Attachment D
Page 1
Notification Response Form
ZA17-065
Meeting [date: October 19, 2017 at 6;30 PM
BOWENSLLTCr� ��Ed
Pb BOX 96011
SOUTHLA'K6 TX 76092 11;x(_ t 1 t} ?C.17
By—
Di rer-t
y
Direct 4u tions and mail responses to;
City of Southlake
Planning & Devel€spmont Services
Notification iRospons•e
1400 Main t; Ste 310
Southlake, TX 76092
Phone: (817) 748-8621
Fax: (817) 748-8077
PLEASE: PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY
BEFORE THE START OF THE SCHEDULED PUBLIC HEARING.
Being the owner(s) of the property so noted above, are hereby
�in favor of opposed to undecided about
-- - (circle or underline one)
the proposed Site Plan referenced above.
Space for comments regarding your position:
Signature,
.Additional Signature:
Date,
Data:
printed Nay ne(s):
t.kjol be properly owmr(sj whose Aart*(s) are pi pled at top. Otherwise coftimt 11* Planning Departrrrent, One €arae per property
Phone Number (optional); ZZ41 - 4f I -
Case No. Attachment D
ZA17-065 Page 2
Notification Response Form
ZA 17-06 S
Meeting Date: October 19, 2017 at 6:30 PM
479 N KIMBALL AVE IT
SOUTHLA E TX 7609 tI` 49_. $ '
0�.
Direct questions and maid res poriser, to,
City of Southlake
Planning & Development Services
Notification Response
1400 Main St; Ste- 310
Southlake, TX 76092
Phone: (817) 748-8621
Fax: (817) 748-8077
PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY
BEFORE THE START- OF THE SCHEDULED PUBLIC HEARING,
Being the owner(s) of the property so .noted above, are hereby
in favor ofopposedto undecided about
(circle or underline erne)
the proposed Site Plain referenced above.
Space for comments regarding your position:
Signature: lie
Additional Signature:
Printed Name(s);
Musi be prGpellp awnler(s) whose names} are prirvLed at top. 0I mise contact the Pae
Date:n
Date:
GY�'
r}epartmonl. One f0mi per property.
Phone Number (eptilonall): r 5 � I i
Case No.
ZA17-065
Attachment D
Page 3