Loading...
PZ Item 12 - PresentationZoning Change and Site Plan for DPS North and Site Plan for North Park for a Wall Ball Court ZA17-071 Applicant: Schrickel, Rollins and Associates, Inc. Owner: City of Southlake Request: Approval of a Zoning Change and Site Plan for DPS North and approval of a site plan for North Park to add a wall ball court Location: 100 and 200 E. Dove Road ZA17-071 Aerial View Approved DPS North Site Plan (ZA09-069) Approved North Park Site Plan (ZA10-011) Proposed Site Plan (ZA17-071) Wall Ball Court DPS North North Park Enlarged Proposed Site Plan (ZA17-071) Wall Ball Court DPS North North Park Electric transmission line easement Aerial view north to proposed wall ball court Proposed Wall Ball Court Tree Conservation Plan Approved Landscape Plans (ZA09-069 and ZA10-011) DPS North (ZA09-069) North Park (ZA10-011) Proposed Landscape and Grading Plans (ZA17-071) Wall Ball Court Elevation Details The wall ball court wall is approximately 16’-4” in height by 32’-10” wide and constructed of Hill Country Stone CMU block with a graffiti resistant coating. The end walls will be approximately 16’4” in height by 7’-6” wide and be faced with a Milsap sandstone to match the stone wall at the concession stand. A cast stone logo will be inset into the end walls. Rendering View West Rendering View West Lighting Details VARIANCES TO LIGHTING HAVE BEEN REQUESTED: All lighting must comply with the Lighting Ordinance No. 693, as amended, with regard to type of lighting, intensity, glare and spill-over. Variances for Sport Lighting Design at the North Park Wall Ball Court: Section 4- Luminaires on poles over 42 inches in height shall be either high pressure sodium lights or neutral or warm correlated color temperature LED lights (temperature equal to or less than 4300 degrees Kelvin) or other lights giving a similar soft lighting effect. Applicant is requesting the sports lighting at the North Park Wall Ball Court be allowed to be constructed with lighting that matches the adjacent, existing sports lighting within the North Park property of 4500 degrees Kelvin (exceeding the 4300 degrees Kelvin) Section 5- The maximum outdoor computed or measured illumination level on a property shall not exceed 20 foot candles outdoors at any point, except that lighting under canopies (such as service stations) shall not exceed 30 foot candles. Applicant is requesting the sports lighting at the North Park Wall Ball Court be allowed to be constructed with lighting levels that provide a safe environment for the user/player and that is no greater than the adjacent, existing sport lighting with the North Park property (exceeding the allowable 20 foot candles) Photographs A B C C B A Questions?