PZ Item 12 - PresentationZoning Change and Site Plan for DPS
North and Site Plan for North Park for a
Wall Ball Court
ZA17-071
Applicant: Schrickel, Rollins and Associates, Inc.
Owner: City of Southlake
Request: Approval of a Zoning Change and Site Plan for
DPS North and approval of a site plan for North
Park to add a wall ball court
Location: 100 and 200 E. Dove Road
ZA17-071
Aerial View
Approved DPS North Site Plan (ZA09-069)
Approved North Park Site Plan (ZA10-011)
Proposed Site Plan (ZA17-071)
Wall Ball Court
DPS North
North Park
Enlarged Proposed Site Plan (ZA17-071)
Wall Ball Court
DPS North
North Park
Electric transmission
line easement
Aerial view north to proposed wall ball court
Proposed Wall Ball Court
Tree Conservation Plan
Approved Landscape Plans (ZA09-069 and ZA10-011)
DPS North (ZA09-069) North Park (ZA10-011)
Proposed Landscape and Grading Plans (ZA17-071)
Wall Ball Court Elevation Details
The wall ball court wall is
approximately 16’-4” in height by
32’-10” wide and constructed of
Hill Country Stone CMU block with
a graffiti resistant coating. The end
walls will be approximately 16’4” in
height by 7’-6” wide and be faced
with a Milsap sandstone to match
the stone wall at the concession
stand. A cast stone logo will be
inset into the end walls.
Rendering View West
Rendering View West
Lighting Details
VARIANCES TO LIGHTING HAVE BEEN
REQUESTED:
All lighting must comply with the Lighting Ordinance No. 693,
as amended, with regard to type of lighting, intensity, glare
and spill-over.
Variances for Sport Lighting Design at the North Park Wall
Ball Court:
Section 4- Luminaires on poles over 42 inches in height shall
be either high pressure sodium lights or neutral or warm
correlated color temperature LED lights (temperature equal to
or less than 4300 degrees Kelvin) or other lights giving a
similar soft lighting effect. Applicant is requesting the
sports lighting at the North Park Wall Ball Court be
allowed to be constructed with lighting that matches the
adjacent, existing sports lighting within the North Park
property of 4500 degrees Kelvin (exceeding the 4300
degrees Kelvin)
Section 5- The maximum outdoor computed or measured
illumination level on a property shall not exceed 20 foot
candles outdoors at any point, except that lighting under
canopies (such as service stations) shall not exceed 30 foot
candles. Applicant is requesting the sports lighting at the
North Park Wall Ball Court be allowed to be constructed
with lighting levels that provide a safe environment for
the user/player and that is no greater than the adjacent,
existing sport lighting with the North Park property
(exceeding the allowable 20 foot candles)
Photographs
A B
C
C
B
A
Questions?