PZ Item 12 - NarrativeULAK Schrickel, Rollins and Associates, Inc.
�_JE L,W_ Landscape Architecture . Civil Engineering Planning
Victor W. Baxter, RLA
Joseph E. Bradley, PE
J. Spencer Freeman, RLA
DelbertW. Hirst, RLA
September 11, 201 7
Sanford P. LaHue, Jr., PE
Henry L. Parker, RLA
Christian Schnitger, PE
Larry Stone, PE
Cit of Southlake
}�
Janna Tidwell, RLA
R
James R. Williams, RLA
Department of Planning and Development Services
Clint T. Wofford, RLA
1400 Main Street, Suite 310
Southlake Texas 76092
i
Kent E. W. Roll, ASLA of counsel
Albert W. Rollins, PE of counsel
Gene Schrickel (1927-2005)
RE: Cover Letter for the North Park Wall Ball Court Project
Site Plan — Preliminary Submittal
Department of Planning and Development Services:
Schrickel, Rollins and Associates, Inc, is the authorized representative/applicant for the North Park
Wall Ball Court Site Plan application. The court is located on the northeast corner of Dove Road
and White Chapel Boulevard at 100 East Dove Road in the City of Southlake, Texas.
The property is approximately ±12 acres of existing City -owned property that contains the DPS
North Facility (Fire Services, Training Classrooms & Firing Range), concrete hike & bike trail,
vehicular drives and parking. The eastern edge of the property abuts a 70ft. Texas Power & Light
Transmission Easement. The property is currently zoned "SP1" (Detailed Site Plan).
The Site Plan Application includes the following proposed improvements to North Park:
1. One (1) lighted, synthetic turf Wall Ball Court.
2. A concrete walk will provide access to the court.
3. Irrigation will be provided for the area surrounding the court, and will tie into the existing
North Park irrigation system.
Two (2) variances are requested with the Site Plan Application. Following are the requested
variances:
1. Variance for the Sports Lighting Design at the North Park Wall Ball Court.
a. Section 4 of Lighting Design in the Ordinance Requirements for Outdoor Lighting
states that luminaires on poles over 42" height must not have more than 4300
degrees Kelvin. We request that the sports lighting at the North Park Wall Ball
Court be allowed to be constructed with lighting that matches the adjacent, existing
sports lighting within the North Park property of 4500 degrees Kelvin.
2. Variance for the Sports Lighting Design at the North Park Wall Ball Court.
a. Section 5 of Lighting Design in the Ordinance Requirements for Outdoor Lighting
SRA 5361
1161 Corporate Drive West, Suite 200 Arlington, TX 76006 0 817.649.3216 • Metro: 817.640.8212 • Fax: 817.649.7645 • SRADESIGN.COM
04 1 P, dwi
states that the maximum outdoor computed or measured illumination level on a
property shall not exceed 20 foot candles outdoors at any point, except that
lighting under canopies (such as service stations) shall not exceed 30 foot candles.
We request that the sports lighting at the North Park Wall Ball Court be allowed to
be constructed with lighting levels that provide a safe environment for the
user/player and that is no greater than the adjacent, existing sports lighting within
the North Park property.
Please feel free to contact me if you have any questions regarding the applications for the Site Plan
of the North Park Wall Ball Court project.
Sincerely,
SCHRICIGL, ROLLINS AND ASSOCIATES, INC.
J mes Williams, RLA
Associate & Authorized Representative/Applicant for the Southlake Community Services Department
Cc: Candice Edmondson, Files
SRA 5361