Item 5 - ZA17-013 Glen Alan SalonCase No. ZA17-013 S T A F F R E P O R T April13, 2017 CASE NO: ZA17-013 PROJECT: Site Plan for Glen Alan Salon EXECUTIVE SUMMARY: Glen Alan Salon is requesting approval of a Site Plan on property described as Lot 2R2, Block1, Miron Addition, City of Southlake, Tarrant County, Texas, located at 205 Miron Drive, Southlake, Texas. Current Zoning: "B-1” Business Service Park District. SPIN #8 DETAILS: The proposed Glen Alan Salon is located approximately 275 feet south of the intersection of E. Southlake Blvd. and Miron Drive. The purpose of this item is to seek approval of a Site Plan for the expansion of the parking lot and façade improvements on an existing 3,035 square foot building located at 205 Miron Drive. The current building is a one-story, legal, non-conforming building on .50 acres. The applicant is seeking to enhance the exterior of the west façade with a large window replacing the existing garage door, new entry doors, a proposed stucco tower on the northwest corner of the building , and a stucco façade and a stone water table. The remaining perimeter sides of the building will have a stone water table with the existing metal siding painted to match the proposed stucco facade on the front façade. A trash enclosure will be constructed with st ucco to match the building stucco. The current parking lot will be reconstructed to meet emergency access standard and increase the parking from 8 parking spaces to 18 parking spaces to accommodate clients and staff. The drive will be relocated further south from the existing location on the property and will meet requirements of the Driveway Ordinance. Site Data Summary Glen Alan Salon Existing Zoning B-1 Land Use Designation Office Commercial Gross/Net Acreage .50 acre/.50 acre Total Building Floor Area (Gross) 3,035 sf Building Height/Number of Stories 1 Area of Open Space 8,690 sf Percentage of Open Space 40% Area of Impervious Coverage 13,090 sf Percentage of Impervious Coverage 60% Total Parking Required (1/200 sf) 16 spaces Total Parking Spaces Provided 18 spaces VARIANCE: The applicant is seeking a variance to the Tree Preservation Ordinance to allow Department of Planning & Development Services Case No. ZA17-013 25% preservation of the existing trees rather than the required 50% preservation. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Approval of the Site Plan ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plan Review Summary No. 3, dated April 13, 2017 (D) Surrounding Property Owners Map and Responses (E) Surrounding Property Owners Responses Full Size Plans (for Commission and Council members only ) Link to PowerPoint Presentation Link Narrative Link Plans Page 1 - Site Plan Pages 2-3 Elevations Page 4 - Dumpster Enclosure Details Page 5 - Grading Plan Page 6 - Tree Conservation Plan Page 7 - Landscape Plan Page 8 - Rendered Landscape Plan Page 9 - Landscape Details Page 10 - Water and Sanitary Sewer Plan STAFF CONTACT: Dennis Killough (817) 748-8072 Patty Moos (817) 748-8269 Case No. Attachment A ZA17-013 Page 1 BACKGROUND INFORMATION OWNER: Glen Alan Wood APPLICANT: Paul Cragun, Cumulus Design PROPERTY SITUATION: 205 Miron Drive, Southlake LEGAL DESCRIPTION: Lot 2R2, Block1, Miron Addition LAND USE CATEGORY: Office Commercial CURRENT ZONING: “B-1” Business Service Park District HISTORY: August 7, 1979; City Council approved a zoning change to “H” Heavy Commercial Zoning and a final plat for the Miron Subdivision on a 10 acre tract of land out of the John A. Freeman Survey Abstract 529 (ZA79-20). September 19, 1989; The “B-1” Business Service Park District was approved with the adoption of the Zoning Ordinance No 480 and the official Zoning Map. March 3, 1993; City Council approved a plat revision for Lots 1R and Lots 2-6, Block 1, Miron Addition (ZA92-56). February 3, 1998; City Council approved a plat revision for Lots 2-R-1, 2-R- 2 and 3-R-1-R, Block 1, Miron Addition (ZA97-177). SOUTHLAKE 2030 PLAN: Consolidated Future Land Use Plan The 2030 future land use designation for the site is Office Commercial. The Office Commercial category is a commercial category designed and intended for the exclusive use of office and limited office-related activities. It is established for and will be allocated to those districts best suited for supporting commercial activity of an office character. It has been established to encourage and permit general professional and business offices of high quality and appearance, in attractive landscaped surroundings with the types of uses and design exterior appearance so controlled as to be generally compatible with existing and future adjacent and surrounding residential development. Properties with this designation may serve as a transition between established residential neighborhoods, major roadways, and retail development. Other suitable activities are those permitted in the Public Parks/Open Space and Public/Semi-Public categories previously discussed. Case No. Attachment A ZA17-013 Page 2 Pathways Master Plan & Sidewalk Plan A 5-foot sidewalk is proposed along Miron Drive. TREE PRESERVATION: The site is subject to the City’s Tree Preservation Ordinance No. 585-D as the site is being modified from its current condition. No site plan was previously considered with the construction of the existing building . There is approximately 50% existing tree cover on the site, of which approximately 25% is proposed to be preserved. The Tree Preservation Ordinance 585D requires that a minimum 50% of existing tree cover be preserved. The applicant is seeking a variance to the Tree Preservation Ordinance to allow 25% of the existing trees to be preserved. UTILITIES: There is an existing 8-inch water line and an existing 6-inch sewer line located on Miron Drive. CITIZEN INPUT: A SPIN meeting was not held for this project. STAFF COMMENTS: Attached is Review Summary No. 3, dated March 31, 2017.  The applicant is seeking to improve a legal, non -conforming structure with the masonry stone and stucco on the front façade and the tower element on the northwest corner of the building. The remaining three sides of the building have a stone water table and the existing metal siding will be painted to match the stucco color. Refer to the Plans, pages 3 and 4, for the proposed elevations and rendering of the building.  A non-conforming structure may be improved to reduce the non - conformity in accordance with Section 6 of the Zoning Ordinance No. 480, as amended.  The bufferyard and interior landscaping is not required for this site as the building footprint is not being increased in size. Landscaping is required for the improved parking lot. APPLICABLE REGULATIONS: General Development Standards Applies Comments Overlay Regulations Y Corridor/Residential Building Articulation Y See staff site plan review and staff comments above Masonry Standards Y See staff site plan review and staff comments above Impervious Coverage Y Complies Bufferyards NA Not Applicable Interior Landscape NA Not Applicable for interior landscape, parking lot only Tree Preservation Y Variance Requested and Mitigation proposed Sidewalks Y Complies Case No. Attachment B ZA17-013 Page 1 Case No. Attachment C ZA17-013 Page 1 SITE PLAN REVIEW SUMMARY Case No.: ZA17-013 Review No.: Three Date of Review: 4/13/2017 Project Name: Site Plan for Glen Alan Salon APPLICANT: Cumulus Design/New Summit OWNER: Glen Alan Wood/Salon Paul Cragun Nate Farish/ New Summit P.O. Box 2119 1901 Central, Suite 820 Euless, TX 76039 Phone: (817) 235-0367 Phone: 817-889-3998 Email: paul@cumulusdesign.net Email: nate@newsummithomes.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 3/20/2017 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT THE APPROPRIATE STAFF MEMBER. Planning Review Patty Moos Planner I Phone: (817) 748-8269 Email: pmoos@ci.southlake.tx.us Informational Comment The current metal clad building is a legal, non -conforming structure. Section 6 of the Zoning Ordinance addresses non-conforming structures and the rebuilding of non -conforming structures partially or completely destroyed. A structure may be altered to reduce non -conformity. 6.5 NONCONFORMING STRUCTURES - Where a lawful structure exists at the effective date of this ordinance or amendment thereof that could not be built under the terms of this ordinance by reason of restrictions on area, lot coverage, height, yards, or other characteristics of the structure or its location on the lot, such structure may be continued so long as it remains otherwise lawful, subject to the following provisions: a. Such structure may not be enlarged in a way which increases its nonconformity; b. Such structure may not be altered in a way which increases its nonconformity; c. Should such structure be moved for any reason for any distance whatever, it shall thereafter conform to the regulations of the district in which it is located after it is moved. 6.10 DESTRUCTION OR DAMAGE TO NONCONFORMING STRUCTURE OR USE (Amended by Ordinance 480-BBBB) a. Nonconforming Structures: 1. If a legal nonconforming structure is totally destroyed or partially damaged by the elements, fire, other catastrophe, or other casualty, the structure may not be repaired or reconstructed except in conformity with the provisions of this ordinance. Tree Conservation/Landscape Review Keith Martin Landscape Administrator Phone: (817) 748-8229 E-mail: kmartin@ci.southlake.tx.us Case No. Attachment C ZA17-013 Page 2 TREE CONSERVATION COMMENTS: 1. The applicant is requesting a variance to the Existing Tree Cover Preservation Requirements. The proposed existing tree cover preservation does not comply with the Existing Tree Cover Preservation Requirements of the Tree Preservation Ordinance. There is approximately 50% (40.1%-60%) of existing tree cover on the property and 50% of the existing tree cover is required to be preserved. The applicant is proposing to preserve only 25% of the existing tree cover. VARIANCE REQUESTED * Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 – Existing Tree Cover Preservation Requirements Percentage of existing tree cover on the entire site Minimum percentage of the existing tree cover to be preserved* 0% – 20% 70% 20.1 – 40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-of-way as approved by City Council. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected du ring all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. LANDSCAPE COMMENTS: * The Building footprint is not being increased so no interior landscape or bufferyards are required to be provided. Additional parking is being provided so parking lot landscaping is required to be provided. * Indicates informational comment. # Indicates required items comment. ____________________________________________________________________________________ Public Works/Engineering Review Om Chhetri, P.E., CFM Civil Engineer Phone: (817) 748-8089 E-mail: ochhetri@ci.southlake.tx.us Case No. Attachment C ZA17-013 Page 3 GENERAL COMMENTS: This review is preliminary. Additional requirements may be necessary with the review of civil construction plans. * Sidewalk widths shall conform to the Southlake Pathways Plan. * Use the City of Southlake GPS monuments whenever possible. Monument locations c an be found in the City of Southlake website: http://www.cityofsouthlake.com/index.aspx?NID=266 *=Denotes informational comment. Fire Department Review Kelly Clements Fire Marshal Phone: (817) 748-8233 E-mail: kclements@ci.southlake.tx.us GENERAL COMMENTS: No comments based on submitted information. General Informational Comments * No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. * All mechanical equipment must be screened of view from right-of-ways and residential properties in accordance with the Zoning Ordinance No. 480, as amended. * All lighting must comply with the Lighting Ordinance No. 693, as amended. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * Development must comply with all requirements in Zoning Ordinance No. 480, Section 43, Overlay Zones. * The applicant should be aware that prior to issuance of a building permit, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. * Denotes Informational Comment Case No. Attachment D ZA17-013 Page 1 SURROUNDING PROPERTY OWNERS MAP & RESPONSES SPO # Owner Zoning Address Acreage Response 1. PKY GROUP LLC SP1 1621 E SOUTHLAKE BLVD 1.10 NR 2. BRUTON, PAUL R SP2 1615 E SOUTHLAKE BLVD 1.02 NR 3. BOOTSTRAP INVESTMENTS INC O1 1723 E SOUTHLAKE BLVD 1.03 NR 4. MALIK, NALIA B1 175 MIRON DR 0.63 NR 5. WETRICH REALTY LP B1 325 MIRON DR 0.70 NR 6. ROCKY MOUNTAIN HOLDINGS LLC SP1 345 MIRON DR 1.00 NR 7. MARCH INVESTMENTS LP B1 365 MIRON DR 0.74 NR 8. DALLAS SMSA TOWER HOLDINGS LP B1 340 MIRON DR 0.98 NR 9. TESORIERO HOLDINGS LLC SP2 260 MIRON DR 0.08 NR 10. D2S2M LLC SP2 270 MIRON DR 0.08 NR 11. BEARFOOT INVESTMENTS LLC SP2 300 MIRON DR 0.08 NR 12. HERITAGE PARTNERS III LLC SP2 290 MIRON DR 0.13 NR 13. THORN PROPERTIES LLC SP2 280 MIRON DR 0.11 NR 14. LIGHT, DONALD C SF1-A 200 WESTWOOD DR 1.21 NR 15. ARIANNA SHABAHANG LLC C2 1695 E SOUTHLAKE BLVD 0.54 NR 16. BOOTSTRAP INVESTMENTS INC O1 1725 E SOUTHLAKE BLVD 1.13 NR 17. WOODS, GLEN A B1 205 MIRON DR 0.52 NR 18. CANDY BEARA LLC B1 305 MIRON DR 0.77 NR 19. SOUTHLAKE MIRON LLC SP2 300 MIRON DR 0.11 NR 20. SOUTHLAKE MIRON LLC SP2 300 MIRON DR 0.14 NR 21. SOUTHLAKE MIRON LLC SP2 300 MIRON DR 0.07 NR 22. SOUTHLAKE MIRON LLC SP2 300 MIRON DR 0.07 NR 23. SOUTHLAKE MIRON LLC SP2 300 MIRON DR 0.08 NR 24. RCC MIRON OFFICE LTD SP2 300 MIRON DR 3.73 NR 25. SOUTHLAKE MIRON LLC SP2 300 MIRON DR 0.08 NR 26. Superintendent of Carroll ISD NR 27. Superintendent of Grapevine Colleyville ISD NR Case No. Attachment D ZA17-013 Page 2 28. Superintendent of Northwest ISD 29. Superintendent of Keller ISD F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Twenty-three (23) Responses Received within 200’: In Favor: 0 Opposed: 0 Undecided: 0 No Response: 23 Responses Received: None to date Case No. Attachment E ZA17-013 Page 1 Surrounding Property Owners Responses No Responses to date