Loading...
Item 12 - ZA16-107 SP White's Chapel Office ParkCase No. ZA16-107 S T A F F R E P O R T December 30, 2016 CASE NO: ZA16-107 PROJECT: Site Plan for White’s Chapel Office Park EXECUTIVE SUMMARY: Sage Group is requesting approval of a Site Plan for White’s Chapel Office Park on property described as a portion of Tract 3C, Hiram Granberry Survey, Abstract No. 581, City of Southlake, Tarrant County, Texas, and generally located near the SW corner of W Southlake Blvd and S White Chapel Blvd and addressed as 130 S White Chapel Blvd, Southlake, Texas. SPIN #10. DETAILS: The project is generally located near the SW corner of W Southlake Blvd and S White Chapel Blvd. The purpose of this request is to seek approval of a Site Plan for four to five single-story office buildings totaling between 27,562 and 27,725 square feet. Site Data Summary O-1 Zoning Proposed Land Use Designation Office Commercial (existing) Office Commercial Gross/Net Acreage No Minimum 3.41 / 3.41 (no RoW ded.) Building Site Coverage 50% maximum 18.77% Individual Building Area (sf) 3,000 minimum per building 5,103 min - 10,318 max Total Building Area (sf) N/A 27,725 (Plan A) 27,562 (Plan B) Square footage by use N/A Medical Office = 16,000 Office = 9,627-9,643 Parking Required 141 spaces (108 Med Office) + (33 Gen Office) 145 spaces Maximum Height 35 feet Approx. 26 feet (bldgs. 4, 5) Maximum # of Stories 2.5 Single-Story Impervious Coverage 65% maximum 61.58% Department of Planning & Development Services Case No. ZA16-107 The applicant is presenting two options which affect the number, layout, and size of the buildings. Option A: Consists of five single-story office buildings totaling 27,725 square feet. Buildings 1-3 are each 5,103 square feet and buildings 4 and 5 are each 5,167 square feet. Option B: Consists of four single-story office buildings totaling 27,562 square feet. Buildings 1-3 are identical to Option A. Buildings 4 and 5 are combined into a single 10,318 square foot single-story building. All proposed buildings in both options are single-story and clad in brick and cast stone with a large format brick wainscot designed to simulate the look of stone. Each façade consists of 100% masonry. Although buildings 1-3 sit within the 1:4 slope required in the Residential Overlay, the applicant is showing a setback of 40’ from the residential property line which allows a 20’ single-story building per Section 43.13.a.8. A four lot Plat Showing (ZA16-106) is proposed concurrently with this application which would plat the larger 7.501 acre property up to Southlake Boulevard as Lots 1-4, White’s Chapel Office Park. The current proposal would occupy Lot 1. Lots 2-4 would be reserved for future development. VARIANCES REQUESTED: ACTION NEEDED: 1. Conduct a public hearing 2. Consider Site Plan Approval Current Regulation Request Section 42.4 of the Zoning Ordinance No. 480, as amended, requires that bufferyards be provided on all new nonresidential development along the outer perimeter of a lot or boundary line. Variance to requirement for a Type ‘A’ 10 foot bufferyard between northern property line of Lot 1 and adjoining property lines of Lots 2 through 4, White’s Chapel Office Park, as shown on the proposed Site Plan and Plat Showing (ZA16-106) Case No. ZA16-107 ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Site Plan Review Summary No. 2, dated December 30, 2016 (D) Surrounding Property Owners Map and Responses Full Size Plans (for Commission and Council members only) Link to PowerPoint Presentation Link to Variance Request Link to Plans Page 1 - Site Plan (Option A) Page 2 - Site Plan (Option B) Page 3 - Landscape Plan (Option A) Page 4 - Landscape Plan (Option B) Pages 5, 6 - Tree Conservation Plan Building Elevations: Page 7 - Building Elevations and Renderings (Buildings 1-3) Page 8 - Building Elevations and Renderings (Buildings 4-5) Page 9 - Building Elevations and Renderings (Building 4 - Opt B) Page 10 - Dumpster Elevation Link to SPIN meeting report STAFF CONTACT: Dennis Killough (817) 748-8072 David Jones (817) 748-8070 Case No. Attachment A ZA16-107 Page 1 BACKGROUND INFORMATION OWNER: Gloria Lechler Trust, et al APPLICANT: Sage Group, Inc. PROPERTY SITUATION: Located near the SW corner of W Southlake Blvd and S White Chapel Blvd and addressed as 130 S White Chapel Blvd. LEGAL DESCRIPTION: A portion of Tract 3C, Hiram Granberry Survey, Abstract No. 581, City of Southlake, Tarrant County, Texas, approximately 3.41 acres. LAND USE CATEGORY: Office Commercial CURRENT ZONING: “O-1” Office District HISTORY: - The property was annexed into the Town of Southlake in 1956 as “AG” (Ord. No. 041). - The "O-1" Office District zoning was placed on the property with approval of Zoning Ordinance No. 480 on September 19, 1989. - A Plat Showing for Lot 4, H. Granberry No. 581 Addition for Southlake Baptist Church adjacent to this property was approved in February 1994 (ZA93-87). - A Preliminary Plat which included this lot under the name Medical Villas at Taylor Creek was approved by City Council October 2007 (ZA07-057). - A Final Plat for Lots 1 & 2, Block 1, Medical Villas at Tuscan Creek adjacent to this property was approved by the Planning and Zoning Commission February 2009 (ZA07-155). - A Final Plat of Tract 3C01 in the H. Granbury Survey, No. 581 for Lot 1, Block 1, First Financial Bank adjacent to this property was approved by City Council October 2010 (ZA10-038). - A Zoning Change and Site Plan for Tract 3C, H. Granberry Survey, No. 581 and Tract 1A, Littleberry G. Hall Survey, No. 686 from “O-1” Office District to “S-P-1” Detailed Site Plan District to allow construction of three single-story retail commercial buildings and five single-story office buildings totaling 51,638 square feet was withdrawn at first reading of City Council November 1, 2016 (ZA16-057). SOUTHLAKE 2030 PLAN: Consolidated Future Land Use Plan The 2030 future land use designation for the site is Office Commercial which is defined in the Southlake 2030 plan as follows: Case No. Attachment A ZA16-107 Page 2 OFFICE COMMERCIAL Purpose and Definition: “The Office Commercial category is a commercial category designed and intended for the exclusive use of office and limited office-related activities. It is established for and will be allocated to those districts best suited for supporting commercial activity of an office character. It has been established to encourage and permit general professional and business offices of high quality and appearance, in attractive landscaped surroundings with the types of uses and design exterior appearance so controlled as to be generally compatible with existing and future adjacent and surrounding residential development. Properties with this designation may serve as a transition between established residential neighborhoods, major roadways, and retail development. Other suitable activities are those permitted in the Public Parks/Open Space and Public/Semi-Public categories”. Pathways Master Plan & Sidewalk Plan The Master Pathways Plan shows an existing multi-use trail along W Southlake Blvd adjacent to the site and a future sidewalk along S White Chapel Blvd adjacent to the site. The applicant proposes a connection from the multi-use path to Lot 3 and a 5’ extension of the sidewalk along White Chapel with a connection to Lot 8. TRANSPORTATION ASSESSMENT: Area Road Network and Conditions The site has direct access to W Southlake Blvd, an A6D arterial with a minimum 130’ to 140’ of right of way and indirect access to S White Chapel Blvd, an A2U arterial with a minimum 88’ of right of way. No right of way is proposed to be dedicated with this development. F.M. 1709/Southlake Blvd (17) (Between White Chapel and Shady Oaks) 24hr West Bound (25,385) East Bound (27,182) AM Peak AM (1456)11:45AM–12:45PM Peak AM (2887) 7:00-8:00 AM PM Peak PM (2638) 4:45-5:45PM Peak PM (1825)1:00-2:00PM White Chapel Blvd (57) (Between F.M. 1709 and Continental) 24hr North Bound (4,724) South Bound (4,857) AM Peak AM (561)7:30AM–8:30PM Peak AM (315) 7:30-8:30AM PM Peak PM (354) 5:00–6:00PM Peak PM (484)4:15–5:15PM * Based on the 2015 City of Southlake Traffic Count Report Traffic Impact The proposed development was found not to meet the traffic impact threshold necessary for a Traffic Impact Analysis. Future proposed phases on Lots 2-4 will be evaluated separately based on additional projected traffic generation and will require a Traffic Impact Analysis if the threshold is exceeded. TREE PRESERVATION: There is approximately 9.37% existing tree cover on the site. Tree Preservation Ordinance 585-D requires that 70% of the existing canopy Case No. Attachment A ZA16-107 Page 3 be preserved. The applicant has submitted a Tree Conservation Plan that shows preservation of 92.46% of existing tree cover with an additional 4.76% shown as marginal. The Tree Conservation Plan for Lot 1 conforms to the Tree Conservation Plan proposed with the Plat Showing (ZA16-106). For property sought to be zoned for the Downtown zoning district or a planned development zoning district, including an S-P-1 Site Plan, S-P- 2 Site Plan, Transition, Rural Conservation, Planned Unit Development, or Employment Center zoning district, the City Council shall consider the application for a Conservation Analysis or Plan in conjunction with the corresponding development application. The Planning and Zoning Commission shall review the application and make a recommendation to the City Council regarding the application. The City Council shall approve the Plan or Analysis if the Council finds that the Plan or Analysis provides for the: i. placement of building pads, parking areas, driveways, streets, and utility easements so as to maximize the preservation of environmental features of the property including mature tree stands, natural creeks and ponds, and significant grades; ii. maximizes the preservation of tree cover preservation areas indicated on the Environmental Resource Protection Map; iii. maximizes the preservation of existing tree stands with the potential to buffer residential areas from the noise, glare, and visual effects of nonresidential uses; iv. maximizes the preservation of existing trees, if any, adjoining a natural or man-made drainage creek; v. maximizes the preservation of existing protected trees along rural roadways and other streets as identified and prioritized in the Street Typology designation; and vi. mitigation of altered trees through proposed tree replacement procedures pursuant to this Ordinance. UTILITIES: Water There is an existing 12” water line along Southlake Blvd that will serve this property. Sewer There is an existing 8” sanitary sewer line along the south property line that will serve this property. DRAINAGE: Drainage will generally flow south and west to storm inlets proposed on the property and from there be piped to the existing facility on the Villas of Tuscan Creek property. CITIZEN INPUT: A SPIN meeting was held on December 13, 2016 (SPIN16-39) Link to SPIN Report STAFF COMMENTS: Attached is Site Plan Review Summary No. 2, dated December 30, 2016 Case No. Attachment A ZA16-107 Page 4 Variance Approval Criteria for Bufferyards, Section 42.15: Variances – The responsibility for granting variance shall be as follows: a. City Council: On all site plans and concept plans requiring review by the Planning and Zoning Commission and approval by the City Council, variances to the bufferyards may be granted by the City Council. b. Board of Adjustment: On all other site plans, variances to the bufferyards may be granted by the Board of Adjustment. Case No. Attachment B ZA16-107 Page 1 Case No. Attachment C ZA16-107 Page 1 SITE PLAN REVIEW SUMMARY Case No.: ZA16-107 Review No.: Two Date of Review: 12/30/16 Project Name: Site Plan – White’s Chapel Office Park APPLICANT: Curtis Young OWNER: John Stephen (Steve) Church Sage Group, Inc. Gloria Lechler Trust, et al 1130 N Carroll Avenue 4116 H.C. Meacham Blvd Southlake, Texas 76092 Fort Worth, Texas 76135-9574 Phone: 817-424-2626; Fax: 817-424-2890 Phone: 817-707-6855; Fax: 888-702-6844 Email: cyoung@sage-dfw.com Email: stvfwt@aeiwireless.net CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 12/19/16 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT THE APPROPRIATE STAFF MEMBER. Planning Review David Jones, AICP Principal Planner Phone: (817) 748-8070 Email: djones@ci.southlake.tx.us 1. Provide Type ‘A’ Bufferyard along the remainder of the property line between proposed Lot 1 and proposed lots 2-4. VARIANCE REQUESTED _________________________________________________________________________________ Tree Conservation/Landscape Review E-mail: kmartin@ci.southlake.tx.us Keith Martin Landscape Administrator Phone: (817) 748-8229 TREE CONSERVATION COMMENTS: * Existing tree cover preservation complies with the Existing Tree Cover Preservation Requirements of the Tree Preservation Ordinance. There is approximately 9.37% of existing tree cover on the site and a minimum of 70% would be required to be preserved. 7.54% of the existing tree cover is proposed to be either removed or as marginal, and 92.46% is proposed to be preserved. Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Case No. Attachment C ZA16-107 Page 2 Table 2.0 – Existing Tree Cover Preservation Requirements Percentage of existing tree cover on the entire site Minimum percentage of the existing tree cover to be preserved* 0% – 20% 70% 20.1 – 40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-of-way as approved by City Council. The City Council shall consider the application for a Conservation Analysis or Plan in conjunction with the corresponding development application. The Planning and Zoning Commission shall review the application and make a recommendation to the City Council regarding the application. The City Council shall approve the Plan or Analysis if the Council finds that the Plan or Analysis provides for the: i. placement of building pads, parking areas, driveways, streets, and utility easements so as to maximize the preservation of environmental features of the property including mature tree stands, natural creeks and ponds, and significant grades; ii. maximizes the preservation of tree cover preservation areas indicated on the Environmental Resource Protection Map; iii. maximizes the preservation of existing tree stands with the potential to buffer residential areas from the noise, glare, and visual effects of nonresidential uses; iv. maximizes the preservation of existing trees, if any, adjoining a natural or man-made drainage creek; v. maximizes the preservation of existing protected trees along rural roadways and other streets as identified and prioritized in the Street Typology designation; and vi. mitigation of altered trees through proposed tree replacement procedures pursuant to this Ordinance. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. LANDSCAPE COMMENTS: 1. The North, South, East, and West Bufferyards adjacent to the office/commercial zoned properties are proposed to be 10’ – A bufferyards, but the bufferyards are labeled a 10’ – B. Correct either the labeling of the bufferyards to reflect what is “Provided” in the Bufferyards Summary Chart, or correct the “Provided” section of the North, South, East, and West Bufferyards to reflect the labeled bufferyard. Case No. Attachment C ZA16-107 Page 3 * Upon submission to obtain a Building Permit, the proposed Landscape Plan must be prepared by a Registered Landscape Architect. * Existing tree credits are proposed to be taken for some of the required bufferyard and interior landscape canopy trees. Please ensure that all existing tree taken credits for are in healthy condition and can be properly preserved throughout the construction process. Existing tree credits shall only be granted if the tree/s are in healthy condition and all req uirements of the Tree Preservation Ordinance have been met as determined at the time of inspection for a Permanent Certificate of Occupancy. * Indicates informational comment. # Indicates required items comment. _________________________________________________________________________________ Public Works/Engineering Review Om Chhetri, P.E. Civil Engineer Phone: (817) 748-8089 E-mail: ochhetri@ci.southlake.tx.us GENERAL COMMENTS: 1. This review is preliminary. Additional requirements may be necessary with the review of civil construction plans. 2. Shared driveway access agreement with adjoining properties shall be established. 3. Show sidewalk along White Chapel per the City’s pathway plan. 4. Traffic generation does not meet the threshold criteria, therefore, TIA is waived. * Construction within FM 1709 right of way shall require a permit from TxDOT. * Street intersections shall comply with TDLR/ADA accessibility standards. * Sight distances shall comply with AASHTO guidelines on adjacent collectors and arterials. * Sidewalk widths shall conform to the Southlake Pathways Plan. * Use the City of Southlake GPS monuments whenever possible. Monument locations can be found in the City of Southlake website: http://www.cityofsouthlake.com/index.aspx?NID=266 WATER, SANITARY SEWER AND DRAINAGE COMMENTS: 1. Move the water line point of connection at FM 1709 to the east closer to the existing Fire hydrant at 1709 i.e property boundary shared with the first financial bank. 2. One option shall be selected prior to utility construction so that the water and sewer services Case No. Attachment C ZA16-107 Page 4 for the building/buildings can be installed appropriately. * Based on review and research, it was found that the report prepared by Aqua Terra for Medical Villas at Taylor Creek analyzed the fully developed condition of the watershed and sized the downstream facilities to accept and convey the fully developed flows. Therefore, the requirement of detention is waived. * The size of the water service tap must match the size of the meter. There are no reducers allowed before the meter on the public side. A 1” inch meter must have a 1” tap, etc. * All waterlines, sanitary sewer and storm sewer in easements or right of ways must be constructed to City standards. Cement treated sand (CTS) backfill above the public utilities and underneath the proposed pavement applies. * Storm sewers collecting runoff from public streets shall be RCP and constructed to City standards. * Property drains into a Critical Drainage Structure and requires a fee to be paid prior to beginning construction. * Discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance No. 605. INFORMATIONAL COMMENTS: * Submit 22”x34” civil construction plans and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. Please allow 15 business days for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City’s website: http://www.cityofsouthlake.com/PublicWorks/engineeringdesign.asp * Submit with Civil Construction Plans a Storm Water Pollution Prevention Plan which outlines pre-construction, construction and post-construction erosion control measures. * Improvements within TxDOT Right of way requires TxDOT approval. * A right of way permit shall be obtained from the Public Works Operations Department (817) 748-8082 to connect to the City’s sewer, water or storm sewer system. * A Developer Agreement may be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. * Any hazardous waste being discharged must be pretreated per Ordinance No. 836. *=Denotes informational comment. _________________________________________________________________________________ Fire Department Review Kelly Clements Fire Marshall Phone: (817) 748-8233 E-mail: kclements@ci.southlake.tx.us Case No. Attachment C ZA16-107 Page 5 PLAN A FIRE HYDRANT COMMENTS: Fire Department Connections for sprinkler systems must be within 100 feet of a fire hydrant, and within 50 feet of fire department fire lanes. (Hydrant is exactly 100 feet from the FDC, ensure correct measurement to allow for one 100’ section of fire hose to connect to FDC) PLAN B GENERAL COMMENTS: No comments based on submitted information. _________________________________________________________________________________ General Informational Comments: * Prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. * No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. * This development must comply with Residential Adjacency Overlay Regulations, Sec. 43 Art III. * All lighting must comply with the Lighting Ordinance No. 693, as amended. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * Denotes Informational Comment Case No. Attachment D ZA16-107 Page 1 SURROUNDING PROPERTY OWNERS MAP & RESPONSES SPO # Owner Zoning Physical Address Acreage Response 1. 321 SOUTHLAKE BLVD REAL ESTATE O1 301 W SOUTHLAKE BLVD 0.128 NR 2. ATCC INVESTMENTS LLC O1 301 W SOUTHLAKE BLVD 0.272 NR 3. DAVIS, KEITH SF20A 101 LONDONBERRY TER 0.514 NR 4. FIRST FINANCIAL BANK O1 151 W SOUTHLAKE BLVD 1.619 F 5. GHIA, JAYESH SF20A 124 LONDONBERRY TER 0.512 NR 6. HOFFMAN, HOLLY L SF20A 100 LONDONBERRY TER 0.909 NR 7. IMAN, ASHER S O1 301 W SOUTHLAKE BLVD 0.160 NR 8. KESTER, PAIGE A SF20A 116 LONDONBERRY TER 0.482 NR 9. LAW, TIFFANY SF20A 105 LONDONBERRY TER 0.474 NR 10. LECHLER, GLORIA ETAL O1 130 S WHITE CHAPEL BLVD 7.345 NR 11. LECHLER, GLORIA ETAL O1 0 S WHITE CHAPEL BLVD 0.223 NR 12. LUTHY, ROBERT E SF20A 104 LONDONBERRY TER 0.460 NR 13. MAHALO INVESTMENTS LLC O1 301 W SOUTHLAKE BLVD 0.343 NR 14. MAHALO INVESTMENTS LLC O1 301 W SOUTHLAKE BLVD 1.628 NR 15. MURPHY, TYLER C SF20A 108 LONDONBERRY TER 0.478 NR 16. NMEM LTD SP1 190 S WHITE CHAPEL BLVD 0.950 NR 17. O'DONNELL, PETER SF20A 120 LONDONBERRY TER 0.472 NR 18. RAI, ROHIT SF20A 300 SIR JOHNS CT 0.457 NR 19. SIMON, ANDREA H SF20A 109 LONDONBERRY TER 0.547 NR 20. STEDKE REVOCABLE TRUST SF20A 112 LONDONBERRY TER 0.493 NR 21. TY SHAFER DDS PA O1 301 W SOUTHLAKE BLVD 0.259 NR 22. WHITE'S CHAPEL CEMETERY CS 121 S WHITE CHAPEL BLVD 1.724 NR Case No. Attachment D ZA16-107 Page 2 23. WHITE'S CHAPEL METH CH CS 185 S WHITE CHAPEL BLVD 24.382 NR 24. Superintendent of Carroll ISD NR 25. Superintendent of Grapevine Colleyville ISD NR 26. Superintendent of Northwest ISD NR 27. Superintendent of Keller ISD NR Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Twenty-Five (25) Responses Received: One (1) In Favor Case No. Attachment D ZA16-107 Page 3