Loading...
Item 6A 1st reading City Council Stipulations Letter ST.LOUIS ST.CHARLES DALLAS PHOENIX ® Power House at Union Station 1520 S.Fifth Street 6175 Main Street 2701 E.Camelback Road Suite 307 Suite 367 Suite 175 Cole 304 9814.8Street, br l0Suite 200 St.Charles,636.978 75 MO tel 3 972.624X60 75034 Phoenix,AZ 60�795.4111 tel 6 November 29, 2016 Mr. Ken Baker,AICP Senior Director of Planning & Development Services 1400 Main Street, Suite 310 Southlake,TX 76092 Re: S-P-2 Zoning First City Council Approval -Stipulations Response Delta Southlake Center—15.872 acres Dear Ken, We have addressed the stipulations of the first City Council Reading approval as follows: 1. Additional Parking—We recognize that one of the stipulations was to add 25 to 30 spaces on Lot 1, which would increase the impervious cover. The applicant is prepared to provide this additional parking if required. However, the development team, professional consultants, and hotel operator still contend that any parking above the 337 spaces shown will be underutilized, and will detract from the aesthetics of the development by eliminating greenspace. It should be noted that the growing use of ride hailing apps - such as Uber and Lyft - in lieu of renting, has not been accounted for in any of the parking requirement calculations. We have provided an exhibit accordingly, and we feel this variable is of particular consequence for the target guest. We have provided an exhibit depicting the additional 27 parking spaces that may be constructed on Lot 1 in the future if there is in fact a parking shortage. Additionally, the exhibit shows a second optional parking area on Lot 2 where an additional 63 spaces may be added. These entitlements have been written into the development regulations. Any increase in parking, whether constructed now or in the future, will be done so in accordance with landscaping and screening requirements consistent with the Lot 1 site plan, and as approved through the City's permitting process. 2. Detail of Lot 2 Amenities to be constructed with Lot 1 — the Phase 1 Landscape Plan (1-2.0) has been updated to more clearly define the elements to be constructed, including identification of all species to be planted, including around plantings around the signs. All elements shown on the Phase 1 Landscape Plan - including the traffic circle, two entry signs at White Chapel and two entry signs at SH 114 will be constructed with the development of Lot 1. Further details will be provided during the final design and permitting process, and will confirm with the intent of the concept. 3. Updated Parking Study for future site plans — A stipulation has been added to the development regulations that updated parking studies shall be provided with future site plans. CIVIL ENGINEERING / SURVEYING / PLANNING / LANDSCAPE ARCHITECTURE Cole&Associates, Inc.is a Missouri Corporation d.b.a. Cole Design Group, Inc.in Arizona and Texas,herein referred to as"Cole" Texas Board of Professional Land Surveying Corporate Registration#10193871 Texas Board of Professional Engineers Registration#F-10253 4. Retaining Wall Materials — The design guidelines for the development now only show rough cut stone options per Council preference. 5. Pool Screening—The Phase 1 Landscape Plan calls out the various plantings that will comprise an 8- foot tal I hedge screen. 6. Tree Preservation at Northwest Corner — I met with Keith Martin and Richard Schell on site to review the trees. It was determined that generally all of the trees in the channel area to be preserved until Lot 2 is developed. The tree preservation plan has been modified accordingly with appropriate notes. 7. Hotel Operator Representative - A representative of the Hotel Operator will be present at the second reading to answer any general questions. 8. Multi-Story, Garage and Maximum Retail Use — A stipulation has been added that the Lot 2 Concept Plan is approved for multi-story office/retail buildings and parking garages, with the retail portion not to exceed 30%. A stipulation for Lot 2 has also been added stating that any structure above 3 stories shall be allowed upon approval of a Specific Use Permit. 9. An exhibit has been provided depicting two locations where additional parking could be constructed in the future Please call if you have any questions. Sincerely, Sandy H. Step ens, P.E. V.P. of Regional Operations cc: Mr. Lucien Tujague, Mr. Carl Schwab, Mr. Art Anderson S:\JOBS\Jobs2015\15-0073\PM\Zoning Regulations and Narrative Documents\2016-11-28 Delta Marriott Southlake - Zoning Regulations\2016-11-28 Delta Marriott Southlake-S-P-2 Zoning Regulations.doc CIVIL ENGINEERING / SURVEYING / PLANNING / LANDSCAPE ARCHITECTURE