Item 8 - ZA16-056 SP Southlake Tennis CenterCASE NO:
PROJECT:
EXECUTIVE
SUMMARY:
CITY OF
S0UTHLA1<,.,.,E
Department of Planning & Development Services
STAFF REPORT
July 29, 2016
ZA16-056
Site Plan for Southlake Tennis Center
Barker Rinker Seacat Architecture Inc., on behalf of the City of Southlake is
requesting approval of a Site Plan for the Southlake Tennis Center on property
described as Tract 1CO3 and portions of Tracts 1CO2 and 1B, L.G. Hall Survey,
Abstract No. 686, and Lot 2R2, L.G. Hall No. 686 Addition, City of Southlake,
Tarrant County, Texas and located at 450 W. Southlake Blvd., Southlake,
Texas. Current Zoning: "CS" Community Service District. SPIN Neighborhood
#7.
DETAILS: The project is generally located in the southeast corner of Bicentennial Park
adjacent to the Tom Thumb shopping center. The purpose of the proposed site
plan is to replace the current approximately 4,000 square foot tennis center
building with an approximately 6,100 square foot tennis center and 320 square
foot storage area, to include an approximately 2,000 square foot patio area and
five (5) tennis court shade structures. There are no changes to existing parking,
the vehicular circulation or any of the tennis courts.
Existing Zoning
Land Use Designation
Gross Project Acreage
Total Building Floor Area
Building Height
Number of Stories
Open Space %
Impervious Coverage %
Total Parking Required (1:3 bleacher seats)
Total Parking Spaces Provided
CS
Public Parks / Open Space
1.61 Acres
6,169 sq ft
27% feet
single story
54.4%
45.6%
127
140
VARIANCES
REQUESTED: The following variances are being requested in relation to the proposed
development:
1) Variance to facade articulation under Zoning Ordinance No. 480,
Section 43.19.d.1.c: Vertical Articulation: No horizontal wall shall
extend for a distance greater than three (3) times the height of the wall
without changing height by a minimum of 15% of the wall's height, and
such height change shall continue for a minimum distance equal to at
Case No.
ZA16-056
least 25% of the maximum length of either adjacent plane. The
proposed south fa(;ade, which is visible from FM 1709, does not meet
this requirement.
2) Variance to exposed columns requirement under Zoning Ordinance
No. 480, Section 43.19.d.1.d: Exposed structural support columns shall
be constructed of, or clad in, the same masonry material as the principal
structure. The proposed shade structures include support columns that
are painted steel.
ACTION NEEDED: 1) Conduct a Public Hearing
2) Consider Approval
ATTACHMENTS: (A) Background Information
(B) Vicinity Map
(C) Site Plan Review Summary No. # 2, dated July 29, 2016
(D) Surrounding Property Owners Map and Responses
Full Size Plans (for Commission and Council members only)
Link to PowerPoint Presentation
Link to Narrative
Link to Plans
Page 1 -
Site Plan
Page 2 -
Tree Conservation Plan
Page 3 -
Landscape Plan
Page 9 -
Elevations
Page 10 -
Variance Exhibit
Link to SPIN meeting Report
STAFF CONTACT: Ken Baker
(817) 748-8067
Chris Tribble
(817) 748-8021
Lorrie Fletcher
(817) 748-8069
Case No.
ZA16-056
BACKGROUND INFORMATION
OWNER: City of Southlake
APPLICANT: Barker Rinker Seacat Architecture Inc.
PROPERTY SITUATION: The project is generally located in the southeast corner of Bicentennial
Park adjacent to the Tom Thumb shopping center: 450 W. Southlake
Blvd., Southlake, Texas.
LEGAL DESCRIPTION: Tract 1CO3 and portions of Tracts 1CO2 and 1B, L.G. Hall Survey,
Abstract No. 686, and Lot 2R2, L.G. Hall No. 686 Addition, City of
Southlake, Tarrant County, Texas.
LAND USE CATEGORY: Public Parks / Open Space
CURRENT ZONING: "CS" — Community Service District
HISTORY: - A Zoning Change and Concept Plan was approved by City Council
on February 15, 1994 under Planning Case ZA94-001.
- A Zoning Change and Site Plan was approved by City Council on
July 18, 2000 under Planning Case ZA00-064.
- A Revised Site Plan for shade structures built over spectator seating
was approved by City Council on June 5, 2001 under Planning Case
ZA01-052.
- A Revised Site Plan for improvements to the maintenance facility
and shade structures for the maintenance facility was approved by
City Council on September 4, 2001 under Planning Case ZA01-090.
- A Zoning Change and Site Plan to add 13.14 acres to the park
property and to construct a clock tower was approved by City
Council on March 5, 2002 under Planning Case ZA01-126.
- A Plat Revision for the park was approved by City Council on March
5, 2002 under Planning Case ZA01-137.
- A Revised Site Plan to construct a learning pavilion in the Liberty
Garden area of the park was approved by City Council on October 7,
2003 under Planning Case ZA03-067.
- A Zoning Change and Site Plan was approved by City Council on
November 18, 2008 to add approximately 7 acres to the park and
construct Phase I of the master planned park under Planning Case
ZA08-078.
- A Site Plan to do improvements to Bicentennial Park surrounding the
historical Log Cabin was approved by City Council on April 7, 2009
under Planning Case ZA09-002.
Case No. Attachment A
ZA16-056 Page 1
A Site Plan was approved by City Council on September 18, 2012
for Bicentennial Park Phase II under Planning Case ZA12-057.
A Site Plan was approved by City Council on June 3, 2014 for the
Southlake Community Recreation Center Phase I (Legends Hall)
under Planning Case ZA14-062.
SOUTHLAKE 2030 PLAN: Consolidated Future Land Use Plan
The Southlake 2030 Consolidated Future Land Use Plan designates the
subject property as Public Parks/Open Space. The Future Land Use
Plan defines Public Parks/Open Spaces as public areas designated for
active and passive recreation, such as parks and athletic complexes,
and public open space
for the preservation of n.
the scenic vistas and - - �- - -
natural vegetation of the -
City. This Land Use - -
Plan depicts only -_
existing Public Parks/
1.
Open Space facilities;'
potential Public Parks/
Open Space sites are
illustrated in the Parks,
Recreation, and Open
Space Master Plan.
Parks, Recreation & Open Space/Community Facilities Master Plan
In the Parks, Recreation & Open Space / Community Facilities Master
Plan a number of recommendations were adopted related to
Bicentennial Park. In relation to this specific request, a community
recreation center facility was recommended to be adopted into the
master plan at Bicentennial Park at the location that is currently being
proposed. The recommendation in the Parks, Recreation & Open
Space/ Community Facilities Master Plan reads as follows:
"6. Provide a Multipurpose -Facility with an amphitheater on the
southwest portion of the park. "
Am
Fl®0
BICENTENNIAL PARK
C.—pr-1 Master Pfau m
Case No. Attachment A
ZA16-056 Page 2
The applicant's proposed site plan request is consistent with the
adopted Bicentennial Park Master Plan and also the recommendation
within the Parks, Recreation & Open Space / Community Facilities
Master Plan.
Mobilitv Master Plan
The proposed project is accessed by an internal driveway — Unity Way.
TRANSPORTATION
ASSESSMENT: Area Road Network and Conditions
The proposed project is located within Bicentennial Park. The park is
bound by Shady Oaks Drive, Southlake Boulevard and White Chapel
Boulevard. This is an existing facility that is being demolished and
rebuilt. There should be no additional impacts to traffic. A traffic impact
analysis was not required for this site.
TREE PRESERVATION: The site meets the requirements of the Tree Preservation Ordinance, as
amended, after removal of the three canopy trees as shown on the
proposed plan.
UTILITIES: Utilities exist for this project within the site that serve the existing tennis
center. Minor alignment changes will be made to accommodate the new
Southlake Tennis Center.
DRAINAGE: Storm drainage was accounted for with the design and construction of
Bicentennial Park Phase II. An existing detention pond will receive the
stormwater runoff and control the release into the downstream system.
CITIZEN INPUT: A SPIN meeting was held for this project on July 26, 2016. A link to the
report is provided. Link to SPIN Report
STAFF COMMENTS: Attached is Review Summary No. # 2, dated July 29, 2016.
Variance Approval Criteria for Zoning Ordinance No. 480, as amended,
Section 43:
Variances - At the time of review of any required Concept Plan or
Site Plan, the City Council may grant variances to the
development regulations set forth in this Section and to Section
35.6, "Number of Off -Street Parking Spaces Required." A parking
space variance can only be at the request of the Owner/Applicant
and cannot be required by the City Council as a part of their
approval of any Concept Plan, Site Plan, Developer's Agreement
or by any other means. The City Council shall be limited to
granting a variance to no more than fifteen percent (15%) of the
required number of off-street parking spaces. (As amended by
Ordinance No. 480-000)
To receive a variance, the applicant must demonstrate one
of the following:
(a) A variance will reduce the impact of the project on
surrounding residential properties; or
Case No. Attachment A
ZA16-056 Page 3
(b) Compliance with this ordinance would impair the
architectural design or creativity of the project; or
(c) A variance is necessary to assure compatibility with
surrounding developed properties; or
(d) The proposed construction is an addition to an
existing project that does not meet the requirements
of this ordinance.
Case No. Attachment A
ZA16-056 Page 4
285
LTA Is] IkiIIvaLY, /_1a
Vicinity Map
Southlake Tennis Center
at Bicentennial (Park
12 11� 4 ti�sl 92Fy 1� ...
9.
593 9M 504 9M
y..
an
35*� r 593 X95 597
L
a
n 0
470
py Z
Rlf 599 %2 Spa tia a 2
E ALD g66
20+ 903
�3 �O
Y
X
s "EDC 9.N
I --OD 1 483 1gi _.jy9
359
' 475
102 43F
w
9`ae
„r7 I -i Ilk-2DO
0222 ESOU74LA1(2
(9�Fi6i�r` g9'iit757,
f 929 17T7
v
t
940 1395 132 1128 124 120 118 112 108 194 100
'E
200 29' — 109 105 101
2$ 203 _ a ._ A 230
N
E
5
0 500
ZA 16-056
Site Plan
1.000
2 000
Feet
Case No. Attachment B
ZA16-056 Page 1
SITE PLAN REVIEW SUMMARY
Case No.: ZA16-056 Review No.: Two Date of Review: 07/29/16
Project Name: Site Plan — Southlake Tennis Center
APPLICANT: City of Southlake ENGINEER: Pacheco Koch
Department of Community Services Javier Jaramillo - Phone: 972-235-3031
Kate Meacham Email: jjaramillo@pkce.com
ARCHITECT: Barker Rinker Seacat Arch.
Phone: 817-748-8018
Email: kmeacham@ci.southlake.tx.us
Kip Jameson — Phone: 214-223-0477
Email: kipjameson@brsarch.com
CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 7/28/16 AND WE
OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN
APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED
FURTHER CLARIFICATION, PLEASE CONTACT THE APPROPRIATE STAFF MEMBER.
Planning Review
Lorrie Fletcher
Planner I
Phone: (817) 748-8069
Email:Ifletcher(aci.south lake. tx.us
Per Zoning Ordinance No. 480, Section 43.19.d.1.d, exposed structural support columns shall
be constructed of, or clad in, the same masonry material as the principal structure. The
proposed shade structures include support columns that are painted steel. A variance has
been requested.
2. The building must meet the horizontal and vertical articulation requirements in Zoning
Ordinance No. 480, Section 43.19.d.1.c on all facades that are visible from W. Southlake
Blvd., which are the west and south elevations. The south elevation does not meet the vertical
articulation requirement. A variance has been requested.
Tree Conservation/Landscape Review
E-mail: kmartin@ci.southlake.tx.us
Keith Martin
Landscape Administrator
Phone: (817) 748-8229
TREE CONSERVATION COMMENTS:
Please correct the chart on the Tree Preservation Plan (L02) to show trees 4 and 17 as
removed (in red) in the comments column. The site as a whole still meets the requirements
of the Tree Preservation Ordinance, as amended, after removal of the three canopy trees
shown.
LANDSCAPE COMMENTS:
Indicates informational comment.
# Indicates required items comment.
Case No.
ZA16-056
Attachment C
Page 1
Fire Department Review
Kelly Clements
Fire Marshal
Phone: (817) 748-8233
E-mail: kclements(aci.south lake.tx.us
GENERAL COMMENTS:
An automatic fire sprinkler system will be required for buildings over 6,000 square feet. (Per
2015 I.F.C. Sec. 903.2.11.9 as amended) (Square footage indicated to be 6,169)
The required backflow protection (double check valve) for the sprinkler system can be located
on the riser if the riser is within 100 feet of the water main. If the riser is further than 100 feet
from the main, the double check valve shall be in a pit. Riser rooms shall be a minimum of
5'X5' if the double check is not located on the riser, or a minimum of 6'X6' if it is on the riser.
The Fire Department Connection for the sprinkler system must be within 100 feet of a fire
hydrant, and within 50 of Fire Department access, fire lanes or public street. (A remote FDC is
acceptable to meet the requirement)(FDC not shown on plans)
FIRE LANE COMMENTS:
Fire lanes require a minimum 30 foot inside turn radius and a minimum 54 foot outside turn
radius. (Per 2012 I.F.C. Sec. 503.2.4) (If fire lanes are required for access to FDC)
Fire apparatus access needs to be an all-weather surface, asphalt or concrete, a minimum of
24 feet wide with 6 inch red striping that contains 4 inch white lettering that states "FIRE LANE
NO PARKING" every 25 feet, and able to support the imposed loads of fire apparatus. (A
minimum of 85,000 pounds GVW) (If fire lanes are required for access to FDC)
Informational Comments:
No review of proposed signs is intended with this site plan. A separate building permit is
required prior to construction of any signs.
All mechanical equipment must be screened of view right-of-ways and residential properties in
accordance with the Zoning Ordinance No. 480, as amended.
All lighting must comply with the Lighting Ordinance No. 693, as amended.
All development must comply with the Drainage Ordinance No. 605 and the Erosion and
Sediment Control Ordinance No. 946, as amended.
Development must comply with all requirements in Zoning Ordinance No. 480, Section 43,
Overlay Zones.
Case No. Attachment C
ZA16-056 Page 2
Masonry materials shall mean and include brick, stucco, plaster, cement, concrete tilt wall,
stone, rock or other masonry material of equal characteristics. Stucco and plaster shall only be
considered a masonry material when applied using a 3 -step process over diamond metal lath
mesh to a 7/8th inch thickness or by other processes producing comparable cement stucco
finish with equal or greater strength and durability specifications. Synthetic products (e.g.,
EIFS —exterior insulation and finish systems, hardi plank, or other materials of similar
characteristics) shall not be considered a masonry material.
Development must comply with all requirements in Zoning Ordinance No. 480, Section 33.21,
Building Color Standards for Non -Residential Buildings.
Denotes Informational Comment
Case No. Attachment C
ZA16-056 Page 3
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
SURROUNDING PROPERTY OWNERS MAP & RESPONSES
POWELL, TIMOTHY
CAMPBELL, JOHN E
NATHAN, FRANCIS
PILLOW, TIMOTHY
BABU, VIJAYABALAN
FINDLAY, KATHERINE
REED, JAMISON P
DORAN,TJ
RAY, ANDREW L
GAMAN, WALTER L
MAZUREK, PIOTR
TAYLOR, NICHAOLS
ZITNIK, JAMES K
MCBRIDE, GREGORY
DAVIS, LINDSAY
BURGESS, RIEL
FERNANDEZ, RAUL A
MEDIATE, V S
WELCH, DAVID E
CRITTENDON, JOE C
JEFFERIES, LAN BUI
STEFANKO, EDWARD P
SCHEER, CARY E
SOUTHLAKE, CITY OF
SOUTHLAKE, CITY OF
SOUTHLAKE, CITY OF
Case No.
ZA16-056
=%714
Zoning
I Address
Acreage
Response
SF1-A
455 LOVE HENRY CT
1.88
NR
SF1-A
495 LOVE HENRY CT
1.80
NR
SF1-A
535 LOVE HENRY CT
1.95
NR
SF1-A
575 LOVE HENRY CT
1.92
NR
SF1-A
615 LOVE HENRY CT
1.92
NR
SF20A
560 TRUELOVE TRL
0.72
NR
SF20A
540 OAK HILL DR
0.47
NR
SF20A
545 BRIARRIDGE RD
0.47
NR
SF20A
540 BRIARRIDGE RD
0.46
NR
SF20A
545 TRUELOVE TRL
0.47
NR
SF20A
545 OAK HILL DR
0.46
NR
SF20A
100 GREEN OAKS LN
0.58
NR
SF20A
340 GREEN OAKS LN
0.69
NR
SF20A
120 GREEN OAKS LN
0.47
NR
SF20A
140 GREEN OAKS LN
0.45
NR
SF20A
160 GREEN OAKS LN
0.45
NR
SF20A
200 GREEN OAKS LN
0.46
NR
SF20A
220 GREEN OAKS LN
0.45
NR
SF20A
240 GREEN OAKS LN
0.46
NR
SF20A
260 GREEN OAKS LN
0.45
NR
SF20A
300 GREEN OAKS LN
0.46
NR
SF20A
320 GREEN OAKS LN
0.47
NR
SF1-A
902 EMERALD BLVD
1.07
NR
CS
1.04
NR
CS
4.97
NR
CS
300 W SOUTHLAKE BLVD
10.29
NR
Attachment D
Page 1
HARVEY, ROBERT
SF1-A
901 EMERALD BLVD
1.06
NR
WHITNEY, SCOTT
SF1-A
803 PEARL DR
0.97
NR
Current Owner, Current Owner
SF1-A
805 PEARL DR
1.00
NR
INLAND WESTERN SLAKE SUNTREE
SP2
110 W SOUTHLAKE BLVD
0.90
NR
TEAL, SUZANNE
SF1-A
902 SAN SABA DR
1.00
NR
SHARIF, NAZMA
SF1-A
900 SAN SABA DR
1.03
NR
HATAWAY, WILLIAM
SF1-A
901 SAN SABA DR
1.00
NR
GARCIA, MANUEL F
SF1-A
900 EMERALD BLVD
0.98
NR
STEPHENS, JOHN
SF1-A
903 SAN SABA DR
0.94
NR
SDPP LLC
C2
465 W SOUTHLAKE BLVD
0.70
NR
JAMES LANDSCAPING INC
SF1-A
430 SHADY OAKS DR
3.22
NR
WALL, CRAIG S
SF30
713 EDWARD CT
0.69
NR
BACKLUND, MICHAEL A
SF30
709 EDWARD CT
1.09
NR
JOHNSON, STEVEN
SF20A
707 EDWARD CT
0.65
NR
GRIFFIN, GILBERT
SF20A
703 EDWARD CT
0.64
NR
HIGHBERGER, RHONDA
SF1-A
310 SHADY OAKS DR
1.10
NR
STACY, RANDALL W
SF1-A
300 SHADY OAKS DR
0.98
NR
STACY, RONALD T
SF1-A
330 SHADY OAKS DR
1.04
NR
STACY, ROY J EST
SF1-A
320 SHADY OAKS DR
5.61
NR
SOUTHLAKE OAKS LLC
C2
500 W SOUTHLAKE BLVD
2.53
NR
BANK OF THE OZARKS
SP1
600 W SOUTHLAKE BLVD
1.05
NR
WAYLAND, MARCUS
AG
427 SHADY OAKS DR
4.96
NR
SDPP LLC
C2
475 W SOUTHLAKE BLVD
0.73
NR
TERRA/STRATFORT LP
C2
445 W SOUTHLAKE BLVD
1.02
NR
SOUTHLAKE, CITY OF
CS
379 SHADY OAKS DR
1.35
NR
SOUTHLAKE, CITY OF
CS
315 SHADY OAKS DR
5.15
NR
SOUTHLAKE, CITY OF
CS
285 SHADY OAKS DR
7.14
NR
SOUTHLAKE OAKS II LLC
C2
480 W SOUTHLAKE BLVD
2.19
NR
SOUTHLAKE, CITY OF
CS
275 SHADY OAKS DR
3.88
NR
SOUTHLAKE, CITY OF
CS
400 N WHITE CHAPEL BLVD
9.57
NR
SOUTHLAKE, CITY OF
CS
379 SHADY OAKS DR
2.88
NR
SOUTHLAKE, CITY OF
CS
2.14
NR
SOUTHLAKE, CITY OF
CS
7.76
NR
SOUTHLAKE, CITY OF
CS
11.37
NR
SOUTHLAKE, CITY OF
CS
379 SHADY OAKS DR
1.51
NR
SOUTHLAKE, CITY OF
CS
1.10
NR
SOUTHLAKE, CITY OF
CS
470 W SOUTHLAKE BLVD
2.14
NR
PARKHILL & WRIGHT LLC
01
301 W SOUTHLAKE BLVD
0.14
NR
IMAN, ASHER S
01
301 W SOUTHLAKE BLVD
0.16
NR
321 SOUTHLAKE BLVD REAL ESTATE
01
301 W SOUTHLAKE BLVD
0.13
NR
TY SHAFER DDS PA
01
301 W SOUTHLAKE BLVD
0.26
NR
SOUTHLAKE, CITY OF
CS
450 W SOUTHLAKE BLVD
0.66
NR
SOUTHLAKE, CITY OF
CS
4.50
NR
WHITE HOUSE EXE CENTER LP
SP1
410 W SOUTHLAKE BLVD
1.60
NR
GTE SOUTHWEST INC
CS
400 W SOUTHLAKE BLVD
0.43
NR
CLARDY-RUFFNER
C2
425 W SOUTHLAKE BLVD
0.91
NR
SOUTHLAKE, CITY OF
CS
1.58
NR
BICENTENNIAL FIN CENTER LP
SP2
250 W SOUTHLAKE BLVD
1.17
NR
Case No.
Attachment D
ZA16-056
Page 2
75.
INLAND WESTERN SLAKE SUNTREE
SP2
100 W SOUTHLAKE BLVD
7.74
NR
76.
SOUTHLAKE, CITY OF
CS
2.89
NR
77.
FIRST AMERICAN SAVINGS BANC
SP2
222 W SOUTHLAKE BLVD
1.17
NR
78.
WV PROPERTIES LLC
SP1
351 W SOUTHLAKE BLVD
2.00
NR
79.
MAHALO INVESTMENTS LLC
01
301 W SOUTHLAKE BLVD
1.63
NR
80.
01
301 W SOUTHLAKE BLVD
0.20
NR
81.
SOUTHLAKE SHADY OAKS BUILDINGS
SP1
620 W SOUTHLAKE BLVD
0.99
NR
82.
SOUTHLAKE SHADY OAKS BUILDINGS
SP1
640 W SOUTHLAKE BLVD
1.14
NR
83.
ENERGY VAULT A47 LLC
SP1
660 W SOUTHLAKE BLVD
0.86
NR
84.
CADG GLENMORE LLC
SF1-A
800 W SOUTHLAKE BLVD
19.71
NR
85.
FOUNTAIN FIVE ZERO TWO TR
AG
250 SHADY OAKS DR
10.22
NR
86.
LECHLER, GLORIA ETAL
01
130 S WHITE CHAPEL BLVD
7.35
NR
Notices Sent: Eighty-six (86)
Responses Received within 200': None
Case No. Attachment D
ZA16-056 Page 3