Item 6D
ZA15-126 – Site Plan for Carroll Pointe
Item 6D
1
APPLICANT: GFF Architects
OWNER: Greenway - Carroll Roads Partners, L.P.
REQUEST: Approval of a Site Plan for covered outdoor seating for Building A at Carroll Pointe
LOCATION: 1201
E. SH 114
ZA15-126
On behalf of Greenway – Carroll Roads Partners, L.P., GFF Architects is requesting approval of a Site Plan for covered outdoor seating for Building A at Carroll Pointe located at 1201
E. SH 114
2
Building A
Carroll Ave.
This is an aerial of the proposed project location. The box labeled Building A points to the location of the proposed changes.
In October 2013 a Site Plan for Carroll Pointe was approved
for the development of three one-story retail/restaurant buildings consisting of approximately 44,052 square feet in size on approximately 7.25 acres.
3
The future land use for this site is Town Center
4
The current zoning for this site is “C-3” General Commercial District
5
Proposed Site Plan for Carroll Pointe
Location of proposed outdoor patio
Building A
This slide contains the overall Site Plan for Carroll Pointe.
The red area on the site plan shows the location of Building A and The blue area on the site plan illustrates the location
of the proposed outdoor patio area
6
Proposed Site Plan (Building A)
Location of proposed outdoor patio
This slide is a zoomed in copy of the submitted site plan for the Site Plan application. The applicant is requesting approval of an approximately 1,500 square foot enclosed patio area.
The location of the proposed patio area is shown in red.
7
Previous north elevation – presented December 1, 2015
This slide illustrates the previously presented north elevation as shown to City Council on December 1, 2015.
The applicant is no longer requesting to change the cement plaster color.
8
Previous east elevation – Presented December 1, 2015
This slide illustrates the previously presented east elevation as shown to City Council on December 1, 2015.
The applicant is no longer requesting to change the cement plaster color.
9
Previous west elevation – presented December 1, 2015
This slide illustrates the previously presented west elevation as shown to City Council on December 1, 2015.
The applicant is no longer requesting to change the cement plaster color.
10
Summary of Proposed Modifications to Building A
Here is a summary of the proposed modifications to building A, which will be covered in subsequent slides.
As noted in the table below the summary of proposed changes, the applicant
is requested to reduce the masonry of Building A from the originally approved 94.3% masonry to 93.1% masonry. The proposed reduction slightly lowers the overall site masonry percentage
from 91.8% masonry to 91.3% masonry. The City Council motion for the original Site Plan (case ZA13-065) included language that the project must have 70% non-stucco masonry materials.
As proposed, this proposal is consistent with the original motion.
11
North Elevation with Proposed Changes
This is a slide illustrating the proposed changes to the north elevation. Please note that no signage will be approved with this site plan. The applicant has also been made aware of
this. Staff has not received signage details but based upon the number of signs proposed, this would require a variance to the sign ordinance.
Proposed changes include to the north
elevation include:
-enclosed patio seating with steel railing and simulated stone pedestals with cast stone cap;
-steel framed projected canopy with prefinished metal decking; (this
was previously presented as a fabric canopy with the enclosed patio seating consisting of the same fiber cement material as used on various elevations);
-simulated stone veneer column
wrap (exposed columns require masonry per overlay Section 43);
-proposed galvanized metal planter boxes and a concrete bar top;
-an insulated sectional metal and glass overhead door;
and
-the applicant is proposing cut thin stone veneer in place of existing windows
The applicant previously presented proposed new cement plaster color which is no longer being requested.
12
Photos of Existing North Elevation
Proposed enclosed patio seating location
Proposed cut thin stone veneer in place of existing windows as shown
The image on the bottom illustrates the location of the proposed enclosed patio seating location and the image in the top-right shows the proposed locations of the cut thin stone veneer
to replace existing windows.
Proposed changes include to the north elevation include:
-enclosed patio seating with steel railing and simulated stone pedestals with cast stone cap;
-steel
framed projected canopy with prefinished metal decking; (this was previously presented as a fabric canopy with the enclosed patio seating consisting of the same fiber cement material
as used on various elevations);
-simulated stone veneer column wrap (exposed columns require masonry per overlay Section 43);
-proposed galvanized metal planter boxes and a concrete
bar top;
-an insulated sectional metal and glass overhead door; and
-the applicant is proposing cut thin stone veneer in place of existing windows
The applicant previously presented
proposed new cement plaster color which is no longer being requested.
13
Exterior rendering of the north elevation
14
East Elevation with Proposed Changes
Proposed stained cedar material is the same as what currently exists on the dumpster enclosure on the south elevation of building A
This slide illustrates the proposed changes to the east elevation. (This elevation is visible from SH 114).
Proposed changes to the east elevation include:
-Proposed tongue and groove
cedar, stained. In lieu of existing cut thin stone veneer (this was previously presented as fiber cement siding);
-Proposed dusted frost performance film applied to existing window,
per shopping center standard;
-proposed simulated stone veneer knee wall;
-proposed modified design for 1’ insulated storefront, dark bronze anodized finish;
-proposed galvanized metal
planter boxes;
-proposed enclosed patio seating with steel railing and simulated stone pedestals with cast stone cap;
-proposed steel framed projected canopy with prefinished metal decking
(this was previously presented as a fabric canopy with the enclosed patio seating consisting of the same fiber cement material as used on various elevations);
-proposed concrete bar
top;
-proposed simulated stone veneer column wrap;
-proposed insulated sectional metal and glass overhead door;
The applicant previously presented proposed new cement plaster color
which is no longer being requested.
15
Photo of Existing East Elevation
Applicant proposing tongue and groove stained cedar in lieu of existing thin stone veneer
Proposed enclosed patio seating location
Proposed simulated stone veneer knee wall location
This slide illustrates the east elevation as it is today and highlights some of the proposed changes. The applicant has changed their request from the previous City Council meeting where
the east elevation proposed fiber cement siding in lieu of existing thin stone veneer. This proposal shows proposed tongue and groove cedar, stained, in lieu of the fiber cement. In
order to meet the non-stucco masonry requirements, the applicant has proposed a simulated stone veneer knee wall
Proposed changes to the east elevation include:
-Proposed tongue and
groove cedar, stained. In lieu of existing cut thin stone veneer (this was previously presented as fiber cement siding);
-Proposed dusted frost performance film applied to existing window,
per shopping center standard;
-proposed simulated stone veneer knee wall;
-proposed modified design for 1’ insulated storefront, dark bronze anodized finish;
-proposed galvanized metal
planter boxes;
-proposed enclosed patio seating with steel railing and simulated stone pedestals with cast stone cap;
-proposed steel framed projected canopy with prefinished metal decking
(this was previously presented as a fabric canopy with the enclosed patio seating consisting of the same fiber cement material as used on various elevations);
-proposed concrete bar
top;
-proposed simulated stone veneer column wrap;
-proposed insulated sectional metal and glass overhead door;
The applicant previously presented proposed new cement plaster color
which is no longer being requested.
16
Exterior rendering of the east elevation
17
Rendering of proposed stained cedar infill on the existing East Elevation
18
West Elevation with Proposed Changes
Existing door proposed to be removed
This slide illustrates the proposed changes to the west elevation. The west elevation is visible from N. Carroll Avenue.
Proposed changes to the west elevation include:
-Proposed enclosed
patio seating with steel railing and simulated stone pedestals with cast stone cap (this was previously presented with the enclosed patio seating consisting of the same fiber cement
material as used on various elevations);
-proposed dusted frost performance film applied to existing window in two locations, and in one location the existing door is proposed to be
removed (as shown on slide);
The applicant previously presented proposed new cement plaster color which is no longer being requested.
19
Photo of Existing West elevation
This slide illustrates the proposed changes to the west elevation. The west elevation is visible from N. Carroll Avenue.
Proposed changes to the west elevation include:
-Proposed enclosed
patio seating with steel railing and simulated stone pedestals with cast stone cap (this was previously presented with the enclosed patio seating consisting of the same fiber cement
material as used on various elevations);
-proposed dusted frost performance film applied to existing window in two locations, and in one location the existing door is proposed to be
removed (as shown on slide);
The applicant previously presented proposed new cement plaster color which is no longer being requested.
20
Locations of proposed dusted frost film applied to windows
East Elevation (Right)
Proposed dusted frost performance film applied to existing window
West Elevation (Left)
Proposed dusted frost performance film applied to existing window
This slide illustrates to locations of proposed dusted frost performance film applied to existing window. This is being proposed on the east and west elevations.
Note: the west elevation
shows the existing door to be removed.
21
Existing Patio area and Connectivity to SH 114 Sidewalk
This image shows the existing patio area in front of the east elevation. This view is looking east towards SH 114. The applicant mentioned that there will be no expansion of concrete
for the outdoor patio area.
22
*Based on the greater of 1 space per 100 square feet or 1 space per 3 seats and calculated using submitted Building Plans
The Site Data Summary chart for the entire site area of Carroll Pointe (3 buildings) is shown on the left. Additionally on this page is the parking breakdown for Carroll Pointe based
upon submitted building plans.
As shown in the site data summary parking spaces are distributed by use; restaurant = 60% and retail = 40%. Per Zoning Ordinance, required spaces for
restaurants are calculated at a rate of 1 space per 100 square feet OR 1 space per every 3 seats, whichever is greater.
The chart shows that based upon the approved square feet and
given the 60:40 split for restaurant/retail use, the site is adequately parked.
The submitted building plans for Lolo’s indicate that 71 seats will be in the patio area.
23
Planning & Zoning Commission – November 19, 2015
Approved (7-0) subject to Staff Report dated November 13, 2015 and Site Plan Review Summary No. 1 dated November 13, 2015
24
City Council – December 1, 2015
Tabled (7-0) ZA15-126 tentatively to the January 5 meeting noting there is a possibility that it could be bumped to January 19.
25
Questions?
26
Example of Outdoor Seating Area
27
Overhead Door Examples
Photos are examples from the overhead door company of Brookfield website
28
Overhead Door Example
Photo from the automatic door specialists website
29
30
31
32
33
Materials Approved with Original Site Plan (ZA13-065)
34
Approved Tree Preservation Plan (Za13-065)
35
Approved Landscape plan (ZA13-065)
36
Applicant Exhibit of Proposed Canopy
37
Traffic
38
39
ExistingTrafficCounts
SH 114 Interchange
N. Carroll Ave. at Lakewood Drive
40
Existing Traffic Counts
N. Carroll Ave. at FM 1709
41
Field Observations
Lakewood Drive
PM rush hour is critical peak
Existing median configuration for SB left-turn creates numerous conflict points and potential safety problems
Existing raised island design on retail drive
is not effective
No significant delays along EB and WB approaches during peak periods (queue 1-2 vehs)
Vehicle gaps are created from upstream traffic signals at SH 114 and Federal Way
N. Carroll Avenue
Lakewood Drive
42
Traffic Analysis
Lakewood Drive
Acceptable LOS during the AM peak
EB approach is LOS F during the PM peak
However, avg. queue is only 1 vehicle long
43
Access Alternatives
Wild Wood Lane
Option A (C2U-60’)
Aligns with existing drainage channel between 800 and 850 Wild Wood Lane
Includes TxDOT deceleration lane
ROW acquisition ($252,000)
Construction Cost ($853,000)
Engineering/Survey
($85,000)
Total Project Cost ($1,190,000)
44
Access Alternatives
Wild Wood Lane
Option B (C2U-60’)
Includes TxDOT deceleration lane
ROW acquisition ($210,000)
Construction Cost ($696,000)
Engineering/Survey ($69,600)
Total Project Cost ($975,600)
45
Access Alternatives
Wild Wood Lane
Option C (C2U-60’)
Aligns with existing driveway along SH 114
Does not meet TxDOT spacing requirements from existing off-ramp
Includes TxDOT deceleration lane
ROW acquisition ($168,000)
Construction
Cost ($609,500)
Engineering/Survey ($61,000)
Total Project Cost ($838,500)
46
Access Alternatives
Option D (C2U-60’)
Includes TxDOT deceleration lane
ROW acquisition ($132,000)
Construction Cost ($534,500)
Engineering/Survey ($53,500)
Total Project Cost ($720,000)
Wild Wood Lane
47
Access Alternatives
Lakewood Drive
(Option 1)
Extend median for SB left-turn lane
Add access drive along Lakewood Drive
Stripe EB approach as a two-lane approach (11’ lanes)
No significant change in LOS for EB approach
Reduces conflict
points
Eliminates confusion
Improves safety
Total Project Cost ($30,000)
48
Access Alternatives
Option 1 plus…
Relocate existing driveway along N. Carroll
Modify existing raised island and driveway radius along east approach
Total Project Cost ($85,000)
Lakewood Drive
(Option 2)
49
Access Alternatives
Option 1 plus…
Relocate existing driveway along N. Carroll
Install median island to restrict left-turn from side streets
Total Project Cost ($85,000)
Lakewood Drive
(Option 3)
50
Traffic Analysis – Lakewood Drive
Option 2
Revised traffic for proposed modifications and the future retail development traffic
Delay increases for EB and WB approaches
EB Queue = 2 veh
WB Queue = 1 veh
51
Traffic Analysis – Lakewood Drive
Option 3
No left-turns from side streets
Minimal delay along side streets
Previous left-turns from Lakewood Drive are required to make U-turn south of intersection
52
Lakewood Acres
Conclusions/Recommendations
No significant congestion problem at N. Carroll Avenue & Lakewood Drive
Vehicle gaps are created from upstream traffic signals at SH 114 and Federal Way
Do
not implement access connections from Wild Wood Lane
Option 2 results in fewer restrictions for Lakewood Drive approach
Consider implementing Option 3 if side street delay increases
along Lakewood Drive
53