Loading...
Item 6G Department of Planning & Development Services S T A F F R E P O R T October 14, 2015 CASE NO: ZA15-081 PROJECT: Site Plan for Alliance Drywall REQUEST: On behalf of ZEM Properties, William K. Houp is requesting approval of a Site Plan for proposed Lot 12, H. Decker No. 438 Addition to develop an approximately 10,375 square foot, single story office and warehouse building on approximately .892 acres on property described as Tracts 1B10A, 1B6C1, 1B10C and 1B6C2, Harrison Decker Survey, Abstract No. 438, City of Southlake, Tarrant County, Texas and located at 1207 and 1209 Timberline Ct., Southlake, Texas. The current zoning is “I-1” Light Industrial. DETAILS: William K. Houp, Architect Inc. is requesting approval of a Site Plan for proposed Lot 12 H. Decker No. 438 Addition to develop an approximately 10,375 square foot, single story office and warehouse building on approximately .892 acres. The request runs concurrently with a staff approved Plat Showing application (ZA15-052) for proposed Lot 12 to combine Tracts 1B10A, 1B6C1, 1B10C and 1B6C2. The property is currently zoned “I-1” Light Industrial District. The proposed project falls within the Non- Residential Overlay (Article IV of Section 43 of Zoning Ordinance No. 480, as amended). Alliance Drywall – 1207 Timberline Court Site Data Summary Gross Acreage .892 Acres Net Acreage .892 Acres Number of Proposed Lots 1 Percentage of Site Coverage 59% % of Open Space 41% % of Impervious Coverage 59% Proposed Building Footprint 10,375 sq. ft. No. of Stories 1 Max. Building Height 22’ Office Area – 1,549 sq. ft. Proposed Floor Area by Use: Warehouse Area – 8,825 sq. ft. Office Area (1/300) – 6 Spaces Required Parking Warehouse Area (1/1000) – 9 Spaces Regular Spaces – 28 Proposed Parking Handicap Spaces – 2 (1 Regular HC and 1 Van Accessible) Required Loading Spaces 2 Provided Loading Spaces 2 Area of Outside Storage None Start Construction (Proposed) December 2015 End Construction (Proposed) May 2016 Case No. ZA15-081 Since the Planning & Zoning Commission considered this item on October 8, 2015, the applicant has made changes to the building elevations, primarily as it relates to the proposed masonry materials. Initially, the applicant requested stucco as the masonry material to be used on the north and east building elevations and the applicant has revised the plan so that each is now brick, rather than stucco. Additionally, the Planning & Zoning Commission noted in their motion for the item the applicants’ willingness to address the west elevation with some type of articulation or different materials. The applicant has proposed incorporating both horizontal and vertical articulation on the west building façade, and has also provided two options for masonry details to be considered by the City Council; Option 2A includes a primarily stone masonry façade with precast stone detail, and Option 2B includes a primarily stone façade with brick detail. The applicant prefers and is requesting approval of Option 2A. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Site Plan Approval Request ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information – Link to PowerPoint Presentation (D) Variance Exhibit (E) Site Plan Review Summary No. 3, dated October 13, 2015 (F) Surrounding Property Owners Map (G) Surrounding Property Owners Responses for City Council Members Only (H) Full Size Plans () STAFF CONTACT: Dennis Killough (817) 748-8072 Jerod Potts (817) 748-8195 Case No. ZA15-081 BACKGROUND INFORMATION OWNER: ZEM Properties, Inc. APPLICANT: William K. Houp, Architect, Inc. PROPERTY SITUATION: 1207 and 1209 Timberline Court LEGAL DESCRIPTION: Tracts 1B10A, 1B6C1, 1B10C and 1B6C2, Harrison Decker Survey, Abstract No. 438, City of Southlake, Tarrant County, Texas and located at 1207 and 1209 Timberline Ct., Southlake, Texas. LAND USE CATEGORY: Mixed Use CURRENT ZONING: “I-1” Light Industrial District HISTORY: Tracts 1B10A. 1B6C1, 1B10C & 1B6C2 – 1207 and 1209 Timberline Court -According to TAD, the existing building of approximately 1,320 square feet was built in 1983 -This property was annexed into the City in 1987. -In 1994 Tracts 1B10A, 1B6C1, 1B10C, and 1B6C2 received a zoning change from “MH” to “I-1” (Case # 93-102) CITIZEN INPUT: A SPIN Town Hall Forum was held for this project on August 11, 2015 at Southlake Town Hall. A SPIN Meeting Report is included as Attachment “D” of this report. SOUTHLAKE 2030: Consolidated Future Land Use The Southlake 2030 Future Land Use Plan designates this property as Mixed Use. The image to the right illustrates the Future Land Use for the proposed location. Mixed Use as defined within Southlake 2030: The range of activities permitted, the diverse natural features, and the varying proximity to thoroughfares of areas in the Mixed Use category necessitates comprehensively planned and coordinated development. New development must be compatible with and not intrusive to existing development. Further, special attention should be placed on the design and transition between different uses. Typically, the Mixed Use designation is intended for medium- to higher-intensity office buildings, hotels, commercial activities, retail centers, and residential uses. Nuisance-free, wholly enclosed light manufacturing and assembly uses that have no outdoor storage are permitted if designed to be compatible with adjacent uses. Other suitable activities are those permitted in the Public Parks/Open Space, Public/Semi- Public, Low Density Residential, Medium Density Residential, Retail Commercial, and Office Commercial categories previously discussed. Case No. Attachment A ZA15-081 Page 1 As proposed, this Site Plan is consistent with the Future Land Use Plan. Master Thoroughfare Plan Subdivision Ordinance No. 483-P, as amended, Section 5.02 notes that for Non-Residential Local Streets a R.O.W. width not less than 60’ should be required. The applicant adequately meets this requirement by showing a 60’ R.O.W. width along Timberline Court on the west side of the proposed project site. Pathways / Sidewalk Plan The City’s Zoning Ordinance No. 480, as amended, Section 33.19 requires sidewalks at a minimum of 5’ in width for all development requiring a City council approved Site Plan. The applicant shows an approximately 4’ wide concrete sidewalk on their Site Plan that extends approximately 158’ along Timberline Court to the west of the proposed project site. This will need to be changed to 5’ in order to meet the requirements of the Zoning Ordinance. TRANSPORTATION ASSESSMENT: Area Road Network and Conditions The existing single-story steel building located at 1207 Timberline Court is shown on the Demolition Site Plan as to be razed. The applicant is proposing a single ingress/egress point (driveway) in the southwest corner of proposed Lot 12. The Site Plan indicates approximately 162’ of centerline driveway spacing between the existing driveway on 1213 Timberline Court to the south and the proposed driveway for 1207 Timberline Court. Traffic Impact AM-PM- Use Area Vtpd* AM-IN PM-IN OUT OUT General Office Building (710) 1,549.84 17 2 0 0 2 Warehousing (150) 8,825.16 43 3 2 0 5 Total 10,375 60 5 2 0 7 * Vehicle Trips Per Day * AM-In, AM-Out, PM-In and PM-Out are peak hour generators on a weekday th * Based on the ITE: Trip Generation Manual, 7 Edition UTILITIES: Water There is an existing 6-inch water line along the east side of Timberline Court. Sewer There is an existing 8-inch sanitary sewer line on the west side of Timberline Court. TREE PRESERVATION: There is approximately 47% tree coverage on the site. The applicant has indicated that they will be preserving 78% of the existing tree coverage. According to Tree Preservation Ordinance No. 585-D the applicant is required to preserve a minimum of 50% of the existing tree cover. PLANNING & ZONING COMMISSION: October 8, 2015; Approved (6-0) (ZA15-081) subject to site plan review summary No. 2, dated October 2, 2015, further subject to staff report dated October 2, 2015, and noting the applicants willingness to address the west elevation with some type of articulation or different materials. STAFF COMMENTS: Attached is Site Plan Review Summary No. 3, dated October 13, 2015. Case No. Attachment A ZA15-081 Page 2 N:\\Community Development\\MEMO\\2015 Cases\\081 - SP - ZEM Commercial Site\\Staff Report\\ZA15-081 - CC - 2015-10-20.doc Case No. Attachment A ZA15-081 Page 3 Case No. Attachment B ZA15-081 Page 1 Plans and Support Information Proposed Site Plan Proposed Rendered Site Plan Case No. Attachment C ZA15-081 Page 1 Project Narrative Case No. Attachment C ZA15-081 Page 2 Case No. Attachment C ZA15-081 Page 3 Proposed Building Elevations Proposed North Elevation Proposed South Elevation Proposed West Elevation Options (View from Timberline Court R.O.W.) Case No. Attachment C ZA15-081 Page 4 The applicant has revised the west building elevation following the Planning & Zoning Commission th meeting October 8. The applicant has proposed vertical and horizontal articulation on the west elevation. This project falls within the Non-Residential Development Overlay section of the Zoning Ordinance, and vertical articulation would be required along the north and west elevations if there was visibility from the E. Continental Blvd. ROW. Horizontal articulation is not required per Section 26 of the Zoning Ordinance, and Vertical articulation is only required if there is visibility from the ROW of E. Continental. The applicant has shown two options for the west elevation. Each option features a primary façade masonry material of stone. The difference between the two options is regarding the details around the windows, and the horizontal band across the façade. Option 2B shows brick details, and Option 2A shows precast stone details. The applicant is requesting and prefers the precast stone details, Option 2A. Option 2A – Precast Stone Details (Preferred by Applicant) Option 2B – Brick Details Case No. Attachment C ZA15-081 Page 5 Proposed East Elevation Proposed Floor Plan Case No. Attachment C ZA15-081 Page 6 Proposed Building Articulation Exhibit Note: This project falls within the Non-Residential Development Overlay section of the Zoning Ordinance. According to the General Development Standards within Article IV, Section 43.19 the Non-Residential Development Overlay Standards apply to non-residential development within the City located within 200 of the public right-of-way for Continental Blvd. The applicant has not provided vertical articulation along the north building elevation. According to Zoning No horizontal Ordinance No. 480, as amended, Article IV, Section 43.19.d.1.(c).ii. Vertical Articulation: wall shall extend for a distance greater than three (3) times the height of the wall without changing height by a minimum of 15% of the wall’s height, and such height change shall continue for a minimum distance equal to at least 25% of the maximum length of either adjacent plane. Case No. Attachment C ZA15-081 Page 7 Visibility Photos (Standing in E. Continental Blvd. R.O.W. looking south towards the proposed project site) Proposed Project Site Case No. Attachment C ZA15-081 Page 8 Proposed Tree Conservation Plan Case No. Attachment C ZA15-081 Page 9 Preliminary Utility Layout Existing “Street” Side Fence Brick Columns with Iron Fence Case No. Attachment C ZA15-081 Page 10 Case No. Attachment D ZA15-081 Page 1 Case No. Attachment D ZA15-081 Page 2 Case No. Attachment D ZA15-081 Page 3 Case No. Attachment D ZA15-081 Page 4 Case No. Attachment D ZA15-081 Page 5 Case No. Attachment D ZA15-081 Page 6 Case No. Attachment D ZA15-081 Page 7 SITE PLAN REVIEW SUMMARY ZA15-081Three10/13/15 Case No.: Review No.: Date of Review: Site Plan Project Name: – ZEM Commercial Site (Alliance Drywall) APPLICANT: Owner: William K. Houp, Architect, Inc. ZEM Properties Kim Houp David Maserang 816 Royal Terrace P.O. Box 1725 Hurst, Texas 76053 Colleyville, Texas 76034 Phone: (817) 590-9399 Phone: (817) 577-0661 Fax: (817) 590-9309 Email: wkharchinc@sbcglobal.net Email: rock@sheetrocker.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 10/13/15 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT THE APPROPRIATE STAFF MEMBER. Planning Review Jerod Potts Planner I Phone: (817) 748-8195 Email: jpotts@ci.southlake.tx.us 1. All development must comply with the underlying zoning district regulations. 2. Facade Articulation: On all non-residential buildings, all facades which are visible from rights-of- way as defined in Section 43.19.d., the following vertical articulation must be met (see Exhibit 43-A for clarification). a. Vertical Articulation: No horizontal wall shall extend for a distance greater than three (3) times the height of the wall without changing height by a minimum of 15% of the wall’s height, and such height change shall continue for a minimum distance equal to at least 25% of the maximum length of either adjacent plane. b. Provide articulation as required or demonstrate that the proposed building will not be visible from the R.O.W. on E. Continental. 3. Label the distance between buildings and distance from building to property lines on the site plan. 4. Show any areas intended for outside storage and method of screening if any. Reference Section 43.19 below for Non Residential Development Overlay regulations. If proposing ancillary outdoor storage, please reference Section 43.19 regarding these requirements. 5. An existing light pole is shown near the southeast corner of the proposed Site Plan. Show any additional intended lighting. All lighting must comply with the Lighting Ordinance No. 693, as amended with regard to type of lighting, intensity, glare and spill-over. 6. Please correct the graphic scale on the site plan. The following are recommendations and observations by staff where your application may benefit and does not represent a requirement.  Staff recommends providing a materials sample board. Public Works/Engineering Review Case No. Attachment E ZA15-081 Page 1 Om Gharty Chhetri, P.E., CFM Civil Engineer Phone: (817) 748-8089 Fax: (817) 748-8077 E-mail: ochhetri@ci.southlake.tx.us GENERAL COMMENTS: 1. This review is preliminary. Additional requirements may be necessary with the review of civil construction plans. 2. The proposed sidewalks shall be 5 feet wide. * Street intersections shall comply with TDLR/ADA accessibility standards. * Sight distances shall comply with AASHTO guidelines on adjacent collectors and arterials. * Sidewalk widths shall conform to the Southlake Pathways Plan. * Retaining walls greater than 4-feet including the footing shall require structural plans prepared by a registered engineer in the State of Texas. Retaining walls shall require a permit from the Building Inspections Department prior to construction. * Use the City of Southlake GPS monuments whenever possible. Monument locations can be found in the City of Southlake website: http://www.cityofsouthlake.com/index.aspx?NID=266 * Verify if easement of water/sanitary sewer/storm sewer crossing the site is in an easement. * Water and sanitary sewer cannot cross property lines without being in an easement or right of way. All waterlines, sanitary sewer and storm sewer in easements or right of ways must be constructed to City standards. * The development will be served by 6” water line and 8” sewer line in Timberline Ct. * The size of the water service tap must match the size of the meter. There are no reducers allowed before the meter on the public side. A one inch meter must have a one inch tap, etc. GRADING AND DRAINAGE COMMENTS: 1. Verify size, shape, and/or location of the detention pond (as depicted on the site/concept/development plan). Any changes to size, shape, and/or location of the proposed pond(s) may require a revision to the concept/site/development plan and may need to be approved by the Planning and Zoning Commission and the City Council. 2. All proposed driveway culvert must be sized by an engineer and submitted for approval to the City Engineer. * Property does not drains into a Critical Drainage Structure * Discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance No. 605. INFORMATIONAL COMMENTS: Case No. Attachment E ZA15-081 Page 2 * Submit 22”x34” civil construction plans and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. Please allow 15 business days for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City’s website: http://www.cityofsouthlake.com/PublicWorks/engineeringdesign.asp * Submit with Civil Construction Plans a Storm Water Pollution Prevention Plan which outlines pre- construction, construction and post-construction erosion control measures. New Requirement: Provide Stormwater Pollution Prevention Plan per TXR150000. The plan must include all required elements in Part III, Section F of the permit. The City of Southlake especially reviews Part III, Section F, (1) (g), Maps. The review is for completeness of a plan to prevent pollution (especially sediment) to the Separate Storm Sewer System. It is highly recommended the project manager provide a series of maps for complex projects, including one map showing controls during mass grading and infrastructure, one map showing controls during vertical construction, and one map showing final stabilization (may be but not always equitable to the landscape plan). Please include SWPPP shall be timelines in relation to the project activities for installation and removal of controls. submitted by second review of the civil construction plans. * A right of way permit shall be obtained from the Public Works Operations Department (817) 748-8082 to connect to the City’s sewer, water or storm sewer system. * A Developer Agreement may be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. Construction plans for these improvements must be acceptable to Public Works prior to placing the Developer’s Agreement on the City Council agenda for consideration. * Any hazardous waste being discharged must be pretreated per Ordinance No. 836. *=Denotes informational comment. Tree Conservation/Landscape Review Keith Martin Landscape Administrator Phone: (817) 748-8229 Fax: (817) 481-5713 E-mail: kmartin@ci.southlake.tx.us TREE CONSERVATION PLAN COMMENTS: 1. The proposed Tree Conservation Plan complies with the Existing Tree Cover Preservation Requirements of the Tree Preservation Ordinance. The site contains 47% existing tree cover and 50% of that existing tree cover is proposed to be preserved. Three (3) trees are proposed to be removed which comprise 22% of the existing tree cover. 78% of the existing tree cover is proposed to remain 2. About one (1) foot of fill grade change is proposed within the critical root zone of area of the 30” Oak tree on the northeast side of the building. The proposed amount of grade change will alter the tree and it will be required to be mitigated. Look at limiting the topography grade changes within the area around the tree but not leaving it in a hole. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing Case No. Attachment E ZA15-081 Page 3 trees intended to be preserved. LANDSCAPE AND BUFFERDS COMMENTS: 1. In the bufferyard summary chart the “Required” plant material quantities for the west 10’ – D bufferyard are incorrect. The correct plant material quantities are as follows below. Show the amount of existing tree credits that are being taken in the “Provided” section of the summary chart. 5 – Canopy Trees 7 – Accent Tree 23 – Shrubs 2. Existing tree credits are proposed to be taken for required interior landscape accent trees. Show the amount of existing tree credits that are being taken in the “Provided” section of the Interior Landscape Summary Chart. * Existing tree credits are proposed to be taken for some of the required interior landscape and bufferyards plantings. Credits shall only be granted if the tree/s are in healthy condition and all requirements of the Tree Preservation Ordinance have been met as determined at the time of inspection for a Permanent Certificate of Occupancy. If the existing plants that were given credit toward reducing the required plantings decline within two (2) growing seasons, the owner shall replace that plant with quality plant material equal to the amount of the declined plant. * Indicates informational comment. # Indicates required items comment. Fire Department Review Kelly Clements Fire Marshal Phone: (817) 748-8233 Fax: (817) 748-8181 E-mail: kclements@ci.southlake.tx.us GENERAL COMMENTS: No comments based on submitted information. Community Service/Parks Department Review Peter Kao Construction Manager Phone: (817) 748-8607 Fax: (817) 748-8027 Email: pkao@ci.southlake.tx.us Park Board comments or recommendations: All applicants are required to appear before the Park Board to discuss park dedication issues if requesting fee payments or fee credits. Please contact the Community Services Department at (817) 748-8607 for further details. Land/park dedication requirements: Non-residential developments must provide dedicated parks and/or open space at a ratio of one (1) acre of park land for every fifty (50) non-residential gross acres of development. Case No. Attachment E ZA15-081 Page 4 If fee payment is approved by City Council in lieu of land dedication, non-residential park dedication fees in the amount of $2400 per gross acre x 0.892 acres= $2140.80 will be required. Fees will be collected with the approved developer’s agreement or prior to any permit being issued. Pathway Comments: Should provide pathways consistent with Southlake Master Pathways Plan. Should provide pedestrian access from each building to Trail System or sidewalk connections and between buildings. Should provide 4ft+ concrete sidewalks on both sides of all public and private streets consistent with Article V Street and Right-Of-Way Requirements of the Subdivision Ordinance and all State of Texas accessibility requirements. Informational Comments: * No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. * All mechanical equipment must be screened of view right-of-ways and residential properties in accordance with the Zoning Ordinance No. 480, as amended. * All lighting must comply with the Lighting Ordinance No. 693, as amended. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * The proposed project falls within the Non-Residential Development Overlay (Article IV of Section 43 of Zoning Ordinance No 480, as amended). The applicant should reference this section in comparison to the I-1 Section (Section 26) and apply the more restrictive development regulations as necessary. * Development must comply with all requirements in Zoning Ordinance No. 480, Section 43, Overlay Zones. * Development must comply with all requirements in Zoning Ordinance No. 480, Section 33.21, Building Color Standards for Non-Residential Buildings. * Where a non-residential use abuts a residentially zoned lot or tract or lot having an occupied residential dwelling, a solid fence meeting the material standards of Section 39.2(b) shall be erected along the side and rear property lines abutting said residential lot or dwelling to a height of eight (8) feet. Walls, fences and screening devices should be consistent with Section 39.6. An 8 foot fence is shown which appears to meet the requirements. * The applicant should be aware that prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. * The proposed building is within 200’ of the Continental R.O.W. therefore all building facades shall be constructed in accordance with Masonry Ordinance No. 557 and as described in the Non Residential Corridor Overlay Section 43.19. Please note the following comments from the Residential Corridor Overlay Section regarding properties zoned I-1: a. Where a property is zoned I-1, I-2, or S-P-1 or S-P-2 with I-1 or I-2 uses, all building facades shall be constructed using cement, concrete tilt wall or other masonry materials of similar characteristics (including but not limited to brick, stone, cast-stone pilasters, wainscots, and decorative or architecturally significant awnings). In addition, the use of standard concrete block shall be limited to 10% of any facade visible from adjacent public Case No. Attachment E ZA15-081 Page 5 ROW. Applied or decorative masonry materials shall be incorporated into the facades which are visible from the ROW as required in 43.15. Such features shall cover a minimum of 15% of said facades and may be architectural features such as pilasters and wainscotings. Where applicable, reveals shall be incorporated into the facades. b. Stucco or plaster shall only be allowed when applied using a 3- step process over diamond metal lath mesh to a 7/8th inch thickness or by other processes producing comparable stucco finish with equal or greater strength and durability specifications. The use of synthetic products (e.g., EIFS – exterior insulation and finish systems, hardy plank, or other materials) shall not be considered as masonry material. (As amended by Ordinance 480- PPP) * Mechanical Equipment Screening: All buildings must be designed such that no mechanical equipment (HVAC, etc.) or satellite dishes shall be visible from any rights-of-way as defined in Section 43.19.d. This shall include equipment on the roof, on the ground or otherwise attached to the building or located on the site. * Please note the following comment from Zoning Ordinance No. 480, as amended, Section 43.19.d.2.(b) regarding loading and service areas: Loading and service areas shall be located at the side or rear of buildings. A minimum 8-foot masonry screen shall be required to screen at least 60% of the loading dock or space intended for tractor/semi-trailer delivery from public rights-of-way as defined in Section 43.19.d. Screening materials shall utilize similar masonry materials to the front facade. The accommodation of adequate access for service delivery trucks may be evaluated to determine the extent of screening required. * Denotes Informational Comment Attached: Articulation Evaluation Chart, Receipt Case No. Attachment E ZA15-081 Page 6 Case No. Attachment E ZA15-081 Page 7 Case No. Attachment E ZA15-081 Page 8 Surrounding Property Owners Responses: F: In Favor (1) O: Opposed To U: Undecided NR: No Response SPO # Owner Zoning Physical Address Acreage Response 1. EXPLORER PIPELINE CO I2 2200 MUSTANG CT 15.33225372 2. HANDALON LLC MH 1212 TIMBERLINE CT 0.43700000 3. JOLLY, MALWINDER BAWA MH 1214 TIMBERLINE CT 0.48900000 4. LEE AIR PROPERTIES LLC I1 1947 E CONTINENTAL BLVD 0.74000000 5. LIGHTCAP, WALTER R MH 1206 TIMBERLINE CT 0.47300000 6. MCCLELLAN, TOMMIE LEE MH 1216 TIMBERLINE CT 0.48100000 F STOWE FAMILY PARTNERS 7. I1 1951 E CONTINENTAL BLVD 1.30400000 LTD 8. Superintendent of Carroll ISD Superintendent of Grapevine 9. Colleyville ISD 10. Superintendent of Keller ISD 11. Superintendent of Northwest ISD 12. UNDERWOOD, RICHARD R MH 1210 TIMBERLINE CT 0.46400000 13. ZEM PROPERTIES INC MH 1208 TIMBERLINE CT 0.47300000 14. ZEM PROPERTIES INC I1 1207 TIMBERLINE CT 0.37013864 15. ZEM PROPERTIES INC I1 1209 TIMBERLINE CT 0.37690926 16. ZEM PROPERTIES INC MH 1211 TIMBERLINE CT 0.45047415 17. ZEM PROPERTIES INC MH 1213 TIMBERLINE CT 0.39220463 18. ZEM PROPERTIES INC MH 1215 TIMBERLINE CT 0.36173785 Notices Sent: Thirteen (13) Responses Received: One (1) Case No. Attachment F ZA15-081 Page 1 Surrounding Property Owner Responses Case No. Attachment G ZA15-081 Page 1