Loading...
Item 6E Department of Planning & Development Services S T A F F R E P O R T August 10, 2015 CASE NO:ZA15-073 PROJECT: Plat Revision for Lots 1R1 and 1R2, Block 2, Brewer Addition EXECUTIVE SUMMARY: Barry and Vicki Dinsmore are requesting approval of a Plat Revision for Lots 1R1 and 1R2, Block 2, Brewer Addition on property described as Lot 1R, Block 2, Brewer Addition, an addition to the City of Southlake, Tarrant County, Texas and located at 2903 Florence Rd., Southlake, Texas. Current Zoning: “SF-1B” Single Family Residential District. SPIN Neighborhood #11. REQUEST DETAILS: The applicant is requesting approval of a Plat Revision for Lots 1R1 and 1R2, Block 2, Brewer Addition to divide the existing 3.01 acre Lot 1, Block 2, Brewer Addition into two lots to allow a family member to build a home on the southern lot. The northern lot contains an existing residence and accessory structures. As part of the Plat Revision, the applicant is requesting a reduction of the building line along the side street frontage of the northern lot from forty (40) feet to thirty (30) feet. This will address an existing condition of an accessory building that was constructed over the building line without a permit. Pending Zoning Board of Adjustment case: The existing accessory structures on the current 3.01 acre lot meet the 3% maximum lot coverage requirement for accessory structures. The accessory building that was constructed without a permit is approximately 3,232 square feet and an existing covered seating area is approximately 144 square feet, which totals 3,376 square feet and 3% of the 3.01 acre lot area is approximately 3,934 square feet. The owner would like to divide the 3.01 acre lot into two lots with the northern lot containing the accessory building being approximately 1.96 acres and the southern lot being approximately 1.05 acres. If the Plat Revision proposing the two lots is approved and recorded, the accessory structures as they exists would exceed the 3% maximum lot coverage allowed on the 1.96 acre lot, which is approximately 2,561 square feet, by approximately 815 square feet. The applicant has a Zoning Board of Adjustment (ZBA) case for a Special Exception Use (SEU) for accessory buildings and structures greater than the size permitted as well as a building permit pending the actions of the Board along with this Plat Revision. The Zoning Board of Adjustment case was tabled indefinitely at the June 25, 2015 meeting. The applicant is proposing to remove a 20’ portion of the metal building, which would reduce the floor area to approximately 2,426 square feet. When added to the approximately 144 square foot covered seating area, the total square footage for accessory structures is now proposed to be approximately 2,570, which exceeds the 2,561 square feet allowed by approximately nine (9) feet. A Case No. ZA15-073 Page 1 plot plan of the accessory building showing the 20’ portion to be removed and the portion encroaching into the 40’ front building line is included in Attachment “C” of this report. The building permit has been reviewed and the building is in compliance with all applicable building codes except the front setback. The permit is ready to be issued if the front building setback is brought into conformance with approval of the reduced front building line on the Plat Revision and the SEU is approved by the ZBA. VARIANCE REQUESTS: 1. Section 4 of the Zoning Ordinance, under the definition for “Yards” on page 4- 24, allows the Planning and Zoning Commission as well as City Council to reduce the setback along a side street of a corner lot up to the minimum setback for the district. The typical setback along a street frontage for the SF- 1B zoning district is forty (40) feet. This can be reduced to twenty (20) feet, which is the minimum side yard for the district. The applicant is requesting a thirty (30) foot setback. 2. Subdivision Ordinance No. 483, as amended, Section 5.06(B) requires sidewalks on both sides of all public streets in all residential subdivisions platted or replatted after the effective date of the ordinance. The applicant is requesting a variance to allow no sidewalk on either street frontage due to an existing home on the northern lot and physical constraints along Brewer Rd. adjacent to the southern lot. ACTION NEEDED:Consider approval of a Plat Revision ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information – Link to PowerPoint (D) Plat Review Summary No. 2, dated July 31, 2015 (E) Surrounding Property Owners Map and Responses STAFF CONTACT: Dennis Killough (817) 748-8072 Richard Schell (817)748-8602 Case No. ZA15-073 Page 2 BACKGROUND INFORMATION OWNER/ APPLICANT: Barry and Vicki Dinsmore PROPERTY SITUATION: 2903 Florence Rd. LEGAL DESCRIPTION: Lot 1, Block 2, Brewer Addition LAND USE CATEGORY: Low Density Residential CURRENT ZONING: “SF-1B” – Single Family Residential District HISTORY: The following is the history of the property to the best of our knowledge and belief: - The property was annexed into the City in 1988 and given the “AG” Agricultural District zoning designation. -A Zoning change (ZA90-005) request for from "AG" Agricultural District to "SF- 1B" Single Family Residential District was approved by the City Council on April 17, 1990. -A Preliminary Plat (ZA90-006) for Brewer Addition was approved April 3, 1990. -A Final Plat (ZA90-020) for Brewer addition was approved May 15, 1990 and filed July 18, 1990. -The existing approximately 3,697 square foot residence was built in 1993 (Source: Building Permit). - The City has no record of a building permit being issued for the accessory building. SOUTHLAKE 2030 PLAN: Consolidated Future Land Use Plan The site is designated “Low Density Residential”, which specifies single family detached dwellings at a net density of one or fewer dwelling units per acre. The proposed lots are consistent with this designation. Mobility & Master Thoroughfare Plan The Mobility and Master Thoroughfare Plan shows Florence Rd. to be a two- lane undivided collector street with 60’ of right of way. A minimum of 30’ of right of way dedication measured from the centerline is required. The right of way shown on the plat does not match the existing plat. It appears that adequate right of way has previously been dedicated. The applicant must verify the location of the centerline and dedicate the required additional right of way if necessary. Pathways Master Plan & Sidewalk Plan The Pathways Master Plan and Sidewalk Plan shows a <8’ sidewalk along the south side of Florence Rd. and a > 8’ multi-use trail along the west side of Brewer Rd. Subdivision Ordinance No. 483, as amended requires 4’ sidewalks along all local residential streets. Regardless of average lot size, the developer or builder of a subdivision platted or replatted after the effective date of the Zoning Ordinance shall install sidewalks and/or trails in accordance with the Southlake Pathways Plan. Each owner/home builder within a residential subdivision platted after the effective date of the Zoning Ordinance shall construct sidewalks at the time of construction of the house. The City Engineer Case No. Attachment A ZA15-073 Page 1 will determine if the requirement for the 8’ multi-use trail is roughly proportional to impact of the subdivision. TRANSPORTATION ASSESSMENT: Existing Area Road Network and Conditions The Plat Revision proposes a driveway for the southern lot onto Brewer Rd., which is a local residential street. Traffic Counts are not included for local residential streets in theCity of Southlake Traffic Count Report. The existing home on the northern lot will continue to use the driveway on Florence Rd. WATER & SEWER: The lots will be served by existing 12” water lines in Florence R. and Brewer Rd. An existing 8” sewer line that crosses the existing lot will serve both proposed lots. TREE PRESERVATION: The Tree Preservation Plan shows all trees on both lots to be preserved. CITIZEN INPUT/ BOARD REVIEW: A SPIN meeting was not held for the Plat Revision. PLANNING AND ZONING COMMISSION ACTION: August 6, 2015; Approved (6-0) specifically approving the variance request for the thirty (30) foot front setback, also specifically approving the request for the variance to allow the sidewalk to not be installed, subject to Plat Review Summary No. 2, dated July 31, 2015 and the staff report dated July 31, 2015 and further noting the applicant’s willingness to remove 20’ of the accessory building on the property. STAFF COMMENTS: Attached is Plat Review Summary No. 2, dated July 31, 2015. Case No. Attachment A ZA15-073 Page 2 Case No. Attachment B ZA15-073 Page 1 PLANS AND EXHIBITS Case No. Attachment C ZA15-073 Page 1 PLAT REVISION Case No. Attachment C ZA15-073 Page 2 TREE CONSERVATION PLAN Case No. Attachment C ZA15-073 Page 3 PLOT PLAN OF ACCESSORY BUILDING Case No. Attachment C ZA15-073 Page 4 Plat Review Summary ZA15-073Two07/31/15 Case No.: Review No.: Date of Review: Plat Revision – Lots 1R1 and 1R2, Block 2, Brewer Addition Project Name: APPLICANT: Barry and Vicki Dinsmore SURVEYOR: Timothy Mankin Peiser & Mankin Surveying 2903 Florence Rd. 623 E. Dallas Rd. Southlake, TX 76092 Grapevine, TX 76051 Phone: (817) 614-8251 Phone: (817) 481-1806 E-mail: tmankin@peisersurveying.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 07/31/15 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF PLAT APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT DENNIS KILLOUGH AT (817) 748-8072. 1. The plat must comply with the underlying zoning district. a. The SF-1A zoning district requires a 40’ front building line along both street frontages on corner lots. Zoning Ordinance No. 480, as amended, Section 4, allows the Planning and Zoning Commission to vary the dimensions of the second front building line on corner lots. The applicant is requesting approval of a 30’ building line along Brewer Rd. to bring an existing accessory building located approximately 31’ from the property line into conformance with the zoning district regulations. b. If the property is subdivided as proposed on the plat, the existing accessory building and structures on the northern lot will not comply with the maximum 3% of the lot area allowed for the sum total of all accessory structures in the SF-1A zoning district. The applicant has submitted an application for approval of a Special Exception Use from the Zoning Board of Adjustment to allow sum total of all accessory buildings and structures to exceed the area allowed, The applicant is proposing to remove a portion of the existing metal building on the property, which would reduce the floor area to approximately 2,426 square feet. When added to the approximately 144 square foot covered seating area, the total square footage for accessory structures is proposed to be approximately 2,570, which exceeds the 2,561 square feet allowed by approximately nine (9) feet. 2. The Pathways Master Plan and Sidewalk Plan shows a <8’ sidewalk along the south side of Florence Rd. and a > 8’ multi-use trail along the west side of Brewer Rd. Subdivision Ordinance No. 483, as amended requires 4’ sidewalks along all local residential streets. Regardless of average lot size, the developer or builder of a subdivision platted or replatted after the effective date of the Zoning Ordinance shall install sidewalks and/or trails in accordance with the Southlake Pathways Plan. Each owner/home builder within a residential subdivision platted after the effective date of the Zoning Ordinance shall construct sidewalks at the time of construction of the house. The City Engineer will determine if the requirement for the 8’ multi-use trail is roughly proportional to impact of the subdivision. 3. Tree Preservation Ordinance shows all trees on both lots to be preserved. Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree Case No. Attachment D ZA15-073 Page 1 permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 – Existing Tree Cover Preservation Requirements Percentage of existing tree cover on Minimum percentage of the the entire site existing tree cover to be preserved* 0% – 20% 70% 20.1 – 40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-of-way as approved by City Council. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. The following changes are needed in the “owner’s” dedication and notary: a. Revise the lots in the owner’s dedication to match the lots in the title block – Lot s1R1 and 1R2, Block 2, Brewer Addition. 4. Remove note # 4 regarding structures on the property. 5. Provide easements as necessary to accommodate the extension of any utilities to the lot with the proposed new residence. 6. The following changes are needed regarding Right-of-Way dedication: a. Show and dimension the right of way dedication in accordance with the current Master Thoroughfare Plan. Florence Rd. is designated as a two-lane undivided collector with 60’ of right of way. A minimum of 30’ of right of way dedication measured from the centerline is required. The right of way shown on the plat does not match the existing plat. It appears that adequate right of way has previously been dedicated. Please verify the location of the centerline and dedicate the required additional right of way if necessary. Public Works Review Comments Om Chhetri, P.E.\\ Civil Engineer (817) 748-8089 ochhetri@ci.southlake.tx.us GENERAL COMMENTS: Case No. Attachment D ZA15-073 Page 2 1. Show existing water and sewer lines in the utility plans. Verify if water and sewer are within the easements. INFORMATIONAL COMMENTS: * Discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance No. 605. * Water and sanitary sewer cannot cross property lines without being in an easement or right of way. Community Service Review Comments Park Board comments or recommendations: All applicants are required to appear before the Park Board to discuss park dedication issues if requesting fee payments or fee credits. Please contact the Community Services Department at (817) 748-8607 for further details. Land/park dedication requirements: Residential developments must provide dedicated parks and/or open space at a ratio of one (1) acre of park land for every forty (40) dwelling units. If fee payment is approved by City Council in lieu of land dedication, residential park dedication fees in the amount of $3000 per dwelling unit x 1 dwelling units =$3000. Pathway Comments: Provide pathways consistent with Southlake Master Pathways Plan. Provide pedestrian access from each building to Trail System or sidewalk connections and between buildings. Provide 4ft+ concrete sidewalks on both sides of all public and private streets consistent with Article V Street and Right-Of-Way Requirements of the Subdivision Ordinance and all State of Texas accessibility requirements. The following should be informational comments only ============= ==================== * Staff strongly recommends contacting Pilar Schank in the City Manager’s Office to determine if a SPIN meeting would be beneficial to your application. Pilar can be contacted by phone at (817) 748-8006 or by e-mail at pschankl@ci.southlake.tx.us * All plats filed must have an original signed and stamped Tax Certificate submitted with it from each taxing unit with jurisdiction of the real property, indicating that no delinquent taxes are owed and that taxes for the current year have been paid. After September 1st, a certificate showing that the taxes for that year are paid, but that the taxes for the upcoming year have yet to be calculated is required. (House Bills 1563 & 3101). A copy of this information may be obtained from the Tarrant County Tax Assessor/Collector’s Office located at 100 E. Weatherford St. in Ft. Worth (across from the old red courthouse). There is a service charge of $10 per account for this certificate. For more information contact the Assessor/Collector’s office at 817-212-6847. * We recommend this plat not be filed until the construction plans have been substantially approved. This will ensure adequate easements and finish floor elevations. Minimum finish floor elevations may be required on the following lots pending review of construction plans: Block , Lots * Please submit a revised pdf "check print" prior to submitting the blackline mylar and paper copy with original signatures. Case No. Attachment D ZA15-073 Page 3 blackline * For Tarrant County filing, original signatures and seals will be required on one mylar and one blackline paper copy prior to filing the plat. The mylar and paper copies will not be accepted if any erasures or original ink, other than signatures or seals, appear on the plat. * A Developers Agreement is required prior to construction of any public infrastructure. The Developer's Agreement for this addition should consider streets, drainage, park dedication requirements and fees, off-site sewer extensions, off-site drainage and utility easements and impact fees. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * Denotes Informational Comment Case No. Attachment D ZA15-073 Page 4 Surrounding Property Owners Map SPO # Owner Zoning Property Address Acreage Response Ketchem, Troy L SF1-B 2839 FLORENCE RD 1.64 NR 1. Wilkes, Richard M SF1-B 605 BREWER RD 1.05 NR 2. Zimmerman, Jason SF1-B 615 BREWER RD 1.43 NR 3. Dinsmore, Barry & Vicki SF1-B 2903 FLORENCE RD 3.57 F 4. NR: No Response F: In Favor O: Opposed U: Undecided Case No. Attachment E ZA15-073 Page 1 Surrounding Property Owner Responses Notices Sent Four (4) Responses Received: One (1) Attached Case No. Attachment E ZA15-073 Page 2 Case No. Attachment E ZA15-073 Page 3