Loading...
Item 6BSOUTHLAKE PLANNING & DEVELOPMENT SERVICES STAFF REPORT May 11, 2021 CASE NO: ZA21-0025 PROJECT: Site Plan for The Garden District Residences EXECUTIVE SUMMARY: Cooper & Stebbins, LP is requesting approval of a Site Plan for The Garden District Residences on property described as Lot 1 and a portion of Lot 2, Block 20, Garden District and Phase C Brownstones, an addition to the City of Southlake, Tarrant County, Texas, and located at 301 and 351 Central Ave., Southlake, Texas. Current Zoning: "DT" Downtown District. SPIN Neighborhood #8. DETAILS: A text amendment (ZA10-068) to Section 37 ("DT" Downtown District) of Zoning Ordinance No. 480, as amended, creating the Garden District geographic boundary in Town Square, as well as new definitions and regulations for the "Garden District" and "Garden District Residences" was approved by City Council on May 3, 2011. A Concept Plan (ZA10-069) replacing 68 previously approved brownstones with 10 Brownstones and 130 Garden District units (reduction of 58 Brownstones units) was also approved on May 3, 2011. November 19, 2013; A Garden District Concept Plan Revision (ZA13-011) replaced 130 Garden District Units with 60 Garden District Units (change -70 in Garden District Residences) and the revised Brownstone SUP (ZA13-053) replaced 10 Brownstones with 33 Brownstones (change +23 brownstones). The approved Concept Plan also granted a variance to the allow the residential building to be four floors (Maximum 52' in height). The current request is for approval of a Site Plan for The Garden District Residences, consisting of 58 residential units in two four-story buildings on approximately 2.24 acres. An underground garage with two spaces per unit (116 total spaces) serves both buildings. An additional 29 parallel spaces for guest parking (one space per each two units) is provided along the adjacent streets. The proposed Site Plan is generally consistent with the previously approved Concept Plan (ZA13-011) for the Garden District and Phase C Brownstones that was approved on November 19, 2013, which showed 60 residential units in three four-story buildings. The Site Data Summary Chart is below. Case No. ZA21-0025 SITE DATA SUMMARY (LOT IR, BLOCK 20) EXISTING ZONING DT LAND USE DESIGNATION TOWN CENTER GROSS ACREAGE (LOT I) 97,692 SO. FT. 0R 2.2427 ACRES NO. OF PROPOSED LOTS I OPEN SPACE 1.44 ACRES 1 64.2% AREA OF IMPERVIOUS COVER 38,687 SQ. FT. PERCENTAGE OF IMPERVIOUS COVER 39.6% PERCENTAGE OF SITE COVERAGE OF BUILDING 35.0% NUMBER OF STORIES 4 BUILDING HEIGHT BUILDING A 50'-7' BUILDING B 51'-1' BUILDING USE GARDEN DISTRICT RESIDENCES BUILDING FOOTPRINT (SQUARE FOOTAGE) 34,166 SO. FT. BUILDING A 17,540 SQ. FT. BUILDING B 16,626 SQ. FT. BUILDING SQUARE FOOTAGE (PROPOSED) 136,563 SO. FT. BUILDING A 70,159 SQ. FT. BUILDING B 66,504 SQ. FT. BUILDING UNITS (1) 58 BUILDING A 30 UNITS BUILDING B 28 UNITS PARKING STRUCTURE (HC) 4 REGULAR 8 IVAN PARKING STRUCTURE (REGULAR) III GUEST PARKING 29 START CONSTRUCTION MONTHIYEAR MARCH 2023 END CONSTRUCTION MONTH/YEAR 'SEPTEMBER 2024 ACTION NEEDED: 1) Conduct a public hearing 2) Consider approval of a Site Plan ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Site Plan Review Summary No. 2, dated April 30, 2021 (D) Surrounding Property Owners Map and Responses Link to Presentation Link to Applicant's Presentation Link tn Plans Link to SPIN Report Link to 2035 Corridor Planning Committee Report STAFF CONTACT: Ken Baker (817) 748-8067 Richard Schell (817) 748-8602 Case No. ZA21-0025 BACKGROUND INFORMATION OWNER: Brownstones at Town Square, LP APPLICANT: Cooper & Stebbins, LP PROPERTY SITUATION: 301 and 351 Central Ave. LEGAL DESCRIPTION: Lot 1 and a portion of Lot 2, Block 20, Garden District and Phase C Brownstones LAND USE CATEGORY: Town Center CURRENT ZONING: "DT" Downtown District HISTORY: Key approvals associated with Southlake Town Square and residential development in Town Square: January 7, 1997 (ZA96-145): Original "PUD" Zoning & Concept Plan approved for Southlake Town Square; August 19, 1997 (ZA97-099 and ZA97-100): Southlake Town Square Phase I Development Plan and Site Plan approved; February 4, 2003 (ZA02-104); "DT" Downtown District Zoning & Concept Plan was approved; April 1, 2003 (ZA03-013) Specific Use Permit for the Brownstone residential units was approved. September 7, 2004 (ZA04-057) Preliminary Plat for Block 22, Southlake Town Square was approved. This area has been designated as open space by the approved concept plan, development plan and the previous preliminary plat and has been intended to be dedicated to the City for use as a park. The purpose of this plat is to subdivide the block into two lots so that a final plat may be approved and recorded for the dedication and conveyance of approximately 2 acres of the future 6 acre park in connection with the residential "Brownstone" project. The final platting of the remaining 4 acres is being deferred awaiting further development of the Town Square project. October 5, 2004 (ZA04-066 & ZA04-067): Revised Concept Plan & Site Plan for Southlake Town Square's Grand Avenue District was approved; September 6, 2005 (ZA05-075): Revised Concept Plan for the purpose of relocating open space/park land from Block 22 (3.78 acres open space removed) to Block 19 (2.80 acres open space provided) was approved, which left a shortfall of 0.98 acres of open space. At the time of approval, Cooper & Stebbins was reviewing appropriate potential new park areas in Blocks 11 and 20 and planned to designate new park space in one or both of these blocks, having a combined area of not less than 0.98 acres. Case No. Attachment A ZA21-0025 Page 1 July 17, 2007 (ZA07-050): Zoning Change and Revised Concept Plan for the purpose of changing the block configurations and realigning Division and State Streets to accommodate the proposed DPS Central Facility. This plan also relocates open space from the north side of Division Street to the south side directly adjacent to McPherson Park. This relocation results in 0.51 acres of park land being added to McPherson Park. The applicant requested a 0.44 acre open space reduction from the currently approved concept plan, but City Council denied the request and approved the item with the following stipulations: 1) The City will retain 0.44 acres of open space with location to be determined later; 2) Requiring a schematic for the open space to be brought before Council prior to the final approval of the block north of the Brownstones; 3) Requiring the open space north of the Brownstones to be open to the public. May 3, 2011; (ZA10-068) A text amendment to Section 37 ("DT" Downtown District) of Zoning Ordinance No. 480, as amended, creating new definitions for "Garden District" and "Garden District Residences" as well as providing additional development regulations for such development was approved. May 3, 2011; (ZA10-069) A revised Concept Plan for the Garden District, including 130 Garden District Residences and 10 Brownstones, was approved. November 19, 2013; (ZA13-011) A revised Concept Plan for the Garden District and Brownstones Phase C to allow construction of 60 Garden District Residences and 33 Brownstones for a total of 93 residential units on approximately 7.472 acres was approved. November 19, 2013; (ZA13-012) A Preliminary Plat for Southlake Town Square Garden District and Brownstones Phase C to develop 60 Garden District residential units and 33 Brownstones was approved. November 19, 2013; (ZA13-053) A Specific Use Permit (SUP) for the Brownstones, which includes portions of Phase B, Phase C and the Garden District to develop 33 Brownstones on approximately 4.89 acres was approved. November 19, 2013; (ZA13-054) A Specific Use Permit (SUP) for residential lofts in the Southlake Town Square "DT" Downtown District for The Residences to allow the construction of 38 residential lofts in a five -story building on an approximately 0.60 acre lot was approved allowing for a period of 24 months before commencing construction of the use. September 15, 2015; (ZA15-094) A Specific Use Permit (SUP) for residential lofts in the Southlake Town Square "DT" Downtown District, which proposed a revision of the previous SUP approval to extend the expiration date from November 19, 2015 to March 31, 2016 and to Case No. Attachment A ZA21-0025 Page 2 increase the maximum height from approximately 52' 4" to approximately 59' was denied by City Council. October 20, 2015; (ZA15-107) A Specific Use Permit (SUP) for residential lofts in the Southlake Town Square "DT" Downtown District, which proposed a revision of the previous SUP approval to extend the expiration date from November 19, 2015 to November 20, 2016 and to increase the maximum height from approximately 52' 4" to approximately 59' 3" was approved by City Council (Option 1). October 20, 2015; (ZA15-108) A Specific Use Permit (SUP) for residential lofts in the Southlake Town Square "DT" Downtown District, which proposed a revision of the previous SUP approval to extend the expiration date from November 19, 2015 to November 20, 2016 was denied by City Council (Option 2). November 15, 2016; (ZA16-095) A Specific Use Permit (SUP) for residential lofts in the Southlake Town Square "DT" Downtown District to extend the previous SUP approval expiration date from November 20, 2016 to January 31, 2017 was approved by City Council. SOUTH LAKE 2035 PLAN: Consolidated Future Land Use Plan The 2035 future land use designation for the site is Town Center. Purpose: The purpose of the Town Center land use district is to encourage the creation of a pedestrian -oriented, mixed-use urban environment that serves as Southlake's downtown and center of community life. Definition: The Town Center land use designation is intended to enhance and promote the development of the community's downtown. The goal is to create an attractive, pedestrian -oriented environment that becomes the center of community life in Southlake. It may include compatibly designed retail, office, cultural, civic, recreational, hotel and residential uses. All uses shall be developed with a great attention to design detail and will be integrated into one cohesive district or into distinct sub -districts, each with its own unique characteristics. A mix of different uses is encouraged to create a vibrant, lively, and unique environment. Residential Uses: ■ Residential uses are to be located between the proposed office or retail uses and existing residential neighborhoods. These uses are intended to provide a lower intensity transition between existing neighborhoods and commercial uses. ■ Residential uses should be well integrated with proposed open space and other civic uses to create a sense of place. ■ They should also be integrated with proposed commercial uses in a manner that provides internal automobile and pedestrian access to convenience commercial uses. Case No. Attachment A ZA21-0025 Page 3 TRANSPORTATION ASSESSMENT: PATHWAYS MASTER PLAN: ■ Residential uses are recommended to be to the density and scale that is appropriate based on the context and character of the proposed overall development. The trip generation table from the previously approved Concept Plan (ZA13-011) for the Garden District and Phase C Brownstones is below. A reduction of two units from the previously approved 131 units is proposed. Traffic Impact: Residential Condominium/Townhouse Use (ITE # 230) (Case No. ZA13-011 approved November 19, 2013) Use Units Vtpd* AM -IN AM- PM- PM -OUT OUT IN (Garden District and Brownstones 93 545 7 34 33 18 Phase C The Residences 38 223 3 14 14 7 Garden District and Brownstones 131 768 10 48 47 25 Phase C + The Residences . Vehicle Trips per Day No pathways or sidewalks are shown on the Pathways Master Plan for this property. The Design District Guidelines for Town Square require a minimum 5' sidewalk along all street frontages and a minimum 5' sidewalk is shown on the plans. DRAINAGE: Drainage is generally to the northeast and northwest of the property into existing storm sewer pipes that carry the runoff into existing drainage structures that were sized for the development, including detention areas UTILITIES: The site is served by existing 8" water lines in Central Ave, Park Ridge Blvd. and Meeting St. A connection to an existing 8" sanitary sewer line in Park Ridge Blvd. is shown for Building A. An 8" sanitary sewer line also exists in Meeting St. TREE PRESERVATION: The only existing trees on the property were planted by the developer as street trees and for landscaping around the sales office. Depending on their condition, they are proposed to be relocated into the overall landscaping for the development. CITIZEN INPUT: A SPIN meeting was held on April 27, 2021. Link to SPIN Meeti Report A 2035 Corridor Planning Committee Report was held on March 30, 2021. Link to 2035 Corridor Plannina Committee Report Case No. Attachment A ZA21-0025 Page 4 PLANNING AND ZONING COMMISSION ACTION: May 6, 2021; Approved (6-1) (Kubiak) subject to the Staff Report dated April 30, 2021 and Site Plan Review Summary No. 2, dated April 30, 2021. STAFF COMMENTS: Attached is Site Plan Review Summary No. 2, dated April 30, 2021. Case No. Attachment A ZA21-0025 Page 5 Case No. ZA21-0025 Attachment B Page 1 Vicinity Map 351 and a portion of 301 Central Ave. ^� IS IDN ST :qym Yaw 4 N � 1910 4a n �'✓r. � S� ' 4 Z ^4� PARI{ ksC CT ST E ET u CIVIC I'L PAIN ST w 150 FOUNTAIN % WIAINST C 149Q Y110 1=10 1560 t5i0 t�Ft� 1]S1P 2100 21M 21w F.W. 1709 1E SOIJYHIA KE BW D fids 1 ilii 1211 1155 1iT5 i6i5 5,9 YR1 �' 1iZ3 1ffii 2101 1531 1461 1471 2111 1&L5 p 9955 V21 iffi m B rY { Z _ B4a 1445 ZA21-0025 Site Plan - The Garden District Residences 1D 39-5 ?-q0 A 1.581 Feet Case No. ZA21-0025 Attachment B Page 1 Case No.: ZA21-0025 SITE PLAN REVIEW SUMMARY Review No.: Two Project Name: Site Plan — Southlake Town Square Garden District APPLICANT: Frank Bliss Cooper & Stebbins LP 351 Central Avenue Southlake, TX 76092 Phone: (817) 291-6148 E-mail: frank.bliss@cooper.company Date of Review: 04/30/21 OWNER: Frank Bliss Brownstones at Town Square, LP 351 Central Avenue Southlake, TX 76092 Phone: (817) 291-6148 E-mail: frank.bliss@cooper.company CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 04/19/21 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT RICHARD SCHELL AT (817) 748-8602. 1. An appropriate plat that conforms to the underlying zoning district and to the approved site plan must be processed, approved and recorded with the County prior to the issuance of building permits. Zoning Ordinance No. 480, as amended, Section 37.6.a limits the height of Garden District residential buildings to a maximum of 52' and three (3) stories. A variance was approved with the previous Concept Plan for the Garden District and Phase C Brownstones (ZA13-011) to allow 4' floor penthouses set back from the building facade. A detail exhibit on the 4th story floor plans for Buildings A and B shows an 8" setback from the building fagades of the first three stories in addition to setbacks for terraces. All Garden District residential development shall meet the standards outlined for residential development in the Downtown District Design Guidelines as amended and adopted by City Council. The Design District Guidelines require a minimum 5' sidewalk and a minimum 5' sidewalk along all street frontages is shown on the plans. Staff recommends providing a material sample board. Tree Conservation/Landscape Review Keith Martin Landscape Administrator Phone: (817) 748-8229 E-mail: kmartin(a-)_ci.southlake.tx.us TREE CONSERVATION COMMENTS: The only existing trees on the property were planted by the developer as street trees and for landscaping around the sales office. Depending on their condition, they are proposed to be relocated into the overall landscaping for the development. LANDSCAPE COMMENTS: Case No. Attachment C ZA21-0025 Page 1 1. Please ensure that the proposed street trees are not within thin the right-of-way visibility sight triangle, that they are not proposed in a location that will block stop signs, road signs, and interfere with light poles. Also ensure that they are proposed to be planted at least 10' from any fire hydrant. The proposed landscaping is consistent with the existing landscaping throughout Town Square. Indicates informational comment. # Indicates required items comment. Public Works/Engineering Review Sandra Endy, P.E., Development Engineer Phone: (817) 748-8033 E-mail: sendy(cD-ci.south lake.tx.us GENERAL COMMENTS: This review is preliminary. Additional requirements may be necessary with the review of the civil construction plans. The City agrees that improvements are necessary in the area of Central Ave. and Federal Way, however, we are currently looking into what the necessary improvements will be. The City will take the requested improvements into consideration. WATER COMMENTS: 1. The comment response states that the water connections were provided for both building, however, only one building shows a water connection. Please show the water connections for both buildings. SANITARY SEWER COMMENTS: 2. The comment response states that the sewer connections were provided for both building, however, only one building shows a sewer connection. Please show the sewer connections for both buildings. DRAINAGE COMMENTS: 3. It is unclear how the parking garage will drain. The comment response stated that a grading plan for the parking garage was provided, however, no plan was provided. Please include grading and drainage information for the parking garage. INFORMATIONAL COMMENTS: Submit 22"x34" civil construction plans and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. Please allow 15 business days for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City's website: http://www.citVofsouthlake.com/PublicWorks/engineeringdesign.asp Case No. Attachment C ZA21-0025 Page 2 New Requirement: Provide Stormwater Pollution Prevention Plan (SWPPP) per TXR150000. The plan must include all required elements in Part III, Section F of the permit. The Environmental Coordinator will review the SWPPP. For instructions on how to complete the review of the SWPPP please refer to the Stormwater Management for Construction Sites in: https://www.citVofsouthlake.com/2237/Stormwater-Management-for-Construction-S. SWPPP shall be submitted by second review of the civil construction plans. * NEW REQUIREMENT: Submit with Civil Construction Plans a Retaining Wall Layout sheet. * Retaining walls greater than 4 -feet including the footing shall require structural plans prepared by a registered engineer in the State of Texas. Retaining walls shall require a permit from the Building Inspections Department prior to construction. * A geotechnical report will be required for all private and public roadways. The geotechnical report shall include pavement design parameters for subgrade stabilization. * A right of way permit shall be obtained from the Public Works Operations Department (817) 748-8082 to connect to the City's sewer, water or storm sewer system. * A Developer Agreement may be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. Construction plans for these improvements must be acceptable to Public Works prior to placing the Developer's Agreement on the City Council agenda for consideration. *=Denotes informational comment that don't need to be addressed until Civil Construction Submittals. Fire Marshal Review Kelly Clements Deputy Fire Chief/Fire Marshal (817) 748-8233 kclements(a-)ci.south lake.tx.us GENERAL COMMENTS: The required backflow protection (double check valve) for the sprinkler systems can be located on the riser if the riser is within 100 feet of the water main, measured linearly along the length of the pipe. If the riser is further than 100 feet from the main, the double check valve shall be in a vault. Riser rooms shall be a minimum of 5'X5' if the double check is located in a vault, or a minimum of 6'X6' if it is located on the riser. (Label riser room locations to determine termination point of riser piping, and indicate size of the riser rooms) The Fire Department Connections for the sprinkler systems must be within 100 feet of a fire hydrant, and within 50 feet of fire department fire lanes on the property. (FDC locations not indicated on the plans) Add FDC locations, wall mount or remote connection to meet the distance requirements or add fire hydrants. Fire apparatus access, fire lanes, need to be an all-weather surface, asphalt or concrete, 24 feet wide and able to support the imposed loads of fire apparatus. (Minimum of 85,000 pounds GVW) The entire cul-de-sac driving surface must maintain this width requirement around the island that is indicated on the plans. Case No. Attachment C ZA21-0025 Page 3 General Informational Comments: A SPIN meeting was held April 27, 2021. No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. All mechanical equipment must be screened of view from rights of way and residential properties in accordance with the Zoning Ordinance No. 480, as amended. All lighting must comply with the Lighting Ordinance No. 693, as amended. All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. It appears that this property lies within the 65 LDN D/FW Regional Airport Overlay Zone and will require construction standards that meet requirements of the Airport Compatible Land Use Zoning Ordinance No. 479. The applicant should be aware that prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. Denotes Informational Comment Case No. Attachment C ZA21-0025 Page 4 SURROUNDING PROPERTY OWNERS MAP & RESPONSES � ro -1,100 �i74, 17J0 1910 7.900�SbO 20 PARK MEE ST ;k a � - ---- - o LLJ zsa 1422 o MAIN ST w z 1501 z uiTL44-�] U J N Lu Q N V IV W 115 j u� U Ln1492 U:�l 1560 1570 1580 00 1700 2100 2 FhA 17f1A >n cnl rrwl AVP Rl Vn 1. Owner SLTS GRAND AVENUE II LP Zoning DT Physical Address•Response 1450 PLAZA PL 2.96 NR 2. HD DEVELOPMENT PROPERTIEX LP C3 300 VILLAGE CENTER DR 11.60 NR 3. SLTS GRAND AVENUE II LP DT 1401 FEDERAL WAY 2.44 NR 4. 2016 PARKVIEW CONDOMINIUMS DEV DT 350 CENTRAL AVE 0.58 NR 5. ROCK J M FAMILY TRUST DT 1568 MAIN ST 0.06 NR 6. HAWTON, DEREK AUBREY DT 1566 MAIN ST 0.06 NR 7. COONS, ROBERT DT 1564 MAIN ST 0.06 NR ALEXANDER, STANL DT 11562 MAIN ST 9. CARDILLO, VALENTINO DT 1560 MAIN ST 0.08 NR 10. BRAY, MELINDA DT 1534 MAIN ST 0.07 NR 11. DAPKIEWIEZ, ROBERT DT 1532 MAIN ST 0.06 NR 12. DURANT, RICHARD H DT 1541 MEETING ST 0.09 NR 13. FIELDS, KAREN DT 1543 MEETING ST 0.07 NR 14. BEATTY FAMILY TRUST DT 1545 MEETING ST 0.08 NR 15. KENNEDY, GRAHAM DT 1547 MEETING ST 0.09 O 16. DURANT, THOMAS DT 1557 MEETING ST 0.16 NR 17. PISANI DJ FAMILY TRUST DT 1553 MEETING ST 0.08 NR 18. LORENZ, RONALD DT 1555 MEETING ST 0.08 NR 19. BROWNSTONES AT TOWN SQUARE LP DT 208 PARK RIDGE BLVD 0.05 NR Case No. Attachment D ZA21-0025 Page 1 20. SERAPHIM PROPERTIES LLC DT 1549 MEETING ST 0.07 NR 21. VAUGHN, SUSAN DT 1551 MEETING ST 0.08 NR 22. SHAMROCK PIPELINE CORP, THE C3 1689 E SH 114 0.41 NR 23. SLTS LAND LP DT 1651 E SH 114 5.31 NR 24. SCHIMEK, CHRIS DT 1509 MEETING ST 0.07 NR 25. KUZMICH, STEPHEN DT 1501 MEETING ST 0.16 NR 26. VAUGHN, DAVID DT 1507 MEETING ST 0.09 NR 27. GRISHAM, SHAWN M DT 1505 MEETING ST 0.08 NR 28. AHNER, MAYNARD DT 1530 MAIN ST 0.06 NR 29. STEBBINS, PATRICIA DT 1511 MEETING ST 0.08 NR 30. CENTURION, GLORIA DT 1513 MEETING ST 0.08 NR 31. CURRENT OWNER DT 1515 MEETING ST 0.07 NR 32. ROEMER, GREGORY DT 1519 MEETING ST 0.09 NR 33. DURANT, C DT 1517 MEETING ST 0.08 NR 34. BROWNSTONES AT TOWN SQUARE OWN DT 198 SUMMIT AVE 0.15 NR 35. DURANT, STORMY DT 1523 MEETING ST 0.09 NR 36. CLAHANE, SOL DT 1521 MEETING ST 0.07 U 37. LOGAN, MICHAEL DT 1503 MEETING ST 0.10 NR 38. RAJ, ABHINANDAN DT 1528 MAIN ST 0.06 NR 39. BROWNSTONES AT TOWN SQUARE OWN DT 199 SUMMIT AVE 0.10 NR 40. PLOTT, R DT 1578 MAIN ST 0.16 NR 41. BROWNSTONES AT TOWN SQUARE LP DT 207 PARK RIDGE BLVD 0.10 NR 42. KUZMICH, STEPHEN DT 201 PARK RIDGE BLVD 0.13 NR 43. BROWNSTONES AT TOWN SQUARE LP DT 211 PARK RIDGE BLVD 0.08 NR 44. BROWNSTONES AT TOWN SQUARE LP DT 215 PARK RIDGE BLVD 0.07 NR 45. BROWNSTONES AT TOWN SQUARE LP DT 221 PARK RIDGE BLVD 0.07 NR 46. BROWNSTONES AT TOWN SQUARE LP DT 225 PARK RIDGE BLVD 0.07 NR 47. MAYES, PAYTON DT 231 PARK RIDGE BLVD 0.07 NR 48. BROWNSTONES AT TOWN SQUARE LP DT 241 PARK RIDGE BLVD 0.64 NR 49. GORDON, KEVIN DT 235 PARK RIDGE BLVD 0.08 NR 50. MAYES, WILLIAM DAYTON DT 206 PARK RIDGE BLVD 0.17 NR 51. BROWNSTONES AT TOWN SQUARE LP DT 351 CENTRAL AVE 2.16 NR 52. BROWNSTONES AT TOWN SQUARE LP DT 301 CENTRAL AVE 0.57 NR Responses: F: In Favor O: Opposed To U: Undecided Notices Sent: Forty-two (42) Responses received: Three (3) - Attached P&Z Commission Comment Cards Four (4) - Attached Response received from outside notification area: One (1) - Attached NR: No Response Case No. Attachment D ZA21-0025 Page 2 Responses received within 200' and platted subdivision Notification Response Form ZA21-0025 Meeting Date: May 6, 2021 at 6:30 PM ALEXANDER,STANLEY 1562 MAIN ST SQUTHLAKE, TX 76092 Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St, Ste 310 Southlake, TX 76092 Phone: (817)748-8621 Fax: (817)748-8077 E-mail: rschell@ci.southlake.tx.us PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Beingtj e owrerr(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed Site Plan referenced above_ Space for comments regarding your position: f}lrt e1? i �, ' e i Signature: Date: Additional Signature: Date: Printed Name(s): �tS& Must be property owner(s) whose name{s} are printed at top. Otherwise contact the Planning Department. One form per property. Phone Number (optional): Case No. Attachment D ZA21-0025 Page 3 Richard Schell From: Graham Kennedy Sent:. Tuesday, April 27, 2021 5:32 PM To: Richard Schell Subject: Notification Response Form: Public Hearing Notice ZA21-0025 Hello, I live at 1547 Meeting Street, Southlake, Texas. I have completed the form requested and have included my response in this email and have sent via mail. I have selected "Opposed" as my selection, and have provided rational below. I would be open to the development if some of my concerns are addressed. Here is my typed response in the event you cannot read my handwriting. "I am pro economic development, pro Southlake and I am not opposed to this development in concept. I have two concerns that I would Peke to have addressed. 1. Building B is physically too close to my home. I will be able to see into the condos and vice versa. 2. The traffic flow on meeting street. I would prefer the garage entry would be from Park Ridge Blvd." Thank you, I am looking forward to the meeting. Graham Kennedy Case No. Attachment D ZA21-0025 Page 4 Notification Response Form ZA21-0025 Meeting Date: May 6, 2821 at 6:30 PM KENNEDY, GRAHAM 1547 MEETING ST SOUTHLAKE, TX 76092 Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 14.00 Main St; Ste 310 5outhlake, TX 76092 Phone: (817)748-8621 Fax: (817)748-8071 E-mz;, - sc-heII@ci.southIake.tx.us PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of co osed to undecided about (circle or underline one) the proposed Site Plan referenced above. Space for comments regarding your position: JOLT pro ecp'ic n'4(, �eyd �%eJ aYD S004I11&Ll C*J 1 AW% �%j C o �5 d'.f.yd52 w :W. 'rte 00o%Cw - 1 hat" . 1WO Vic, 404) close.. k -o w% L,\ �z>Y,%e. J-W+able. 4o sCe- gin, `alt roJ6'5 4 yiLe, V ersa . rL Arab i c. "1 l -4w 0- l Ntcl �v.� S�Y G • w *LtU �e 4' om N"a a lse-R (J. Signature: Additional Signature: 1 Printed Name(s): _;rayaw kc>nYN9-1 Must be property owtner(s) whose ndrne(s) are printed at top. Otherwise Date: 0W 1202 i Date: the Manning Uepar[menl. Une rorm per property. Phone Number (optional): -79 L -Z17- 9 �� D Case No. ZA21-0025 Attachment D Page 5 Notification Response Form ZA21-0025 Meeting Date: May 6, 2021 at 6:30 PM CLAHANE, SOL 1521 MEETING ST SQUTHLAKE, TX 76092 Direct questions and mail responses to: City of Southlake Planning +& Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone: (817)748-8621 Fax: (817)748-8077 E-mail: rschell@ci.southlake.tx.us PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to L—undecided about (circle or underline one) the proposed Site Pian referenced above. Space for comments regarding your position: NA f t -w -m ? ma,5+ profect nese pct itiv O r iv -o rev' . va u. e o-�- wk o -s_a re_ cam►"a b L-_ — i.Vl�.�t't �. Signatu Additional IC Date: _45z l Date: z Z l Printed Name(s): Scat Must be property owner(s) whose name(s) are printed at top. Otherwise contact the Planning Department. One form per property. Phone Number (optional): 9rJ-2.-2-4R-5a22 Case No. Attachment D ZA21-0025 Page 6 PU Commission Comment Cards Southlake Planning and Zoning Meeting Public Comment Form Please print. Return completed form to Commission Secretaprior to start of regular session. Name: Uj �, \�, Address: I S eks - Date - C3I wish to share my views on an Agenda Item: b I will speak in SUPPORT of this item I will s Leak in OPPOSITION of this item I do not wish to s caL bur wish to record rnSUPP- PPOSITION Signature: Required- Cards will riot be read into the record unless it is signed. Southlake Planning and Zoning Meeting Public Comment Form Please print. Return com tete /form to Commission Secreta prior co, st rt of re Iar session. Name: _ J / Eo Address: ZZ- O R V\ 't< 2 Phone: - Date: [✓ l wish to share my views on an .Agenda Irem: I willspeak in SUPPORT of this item I will speak inOPPOSITIONof this item I do not wish to speak, but wish to record my SUPPORT'/ OPP SIT©N Signature: not be rend into the record unless it is Case No. Attachment D ZA21-0025 Page 7 Southlake Planning and Zoning Meeting Public Comment Form Please print. Return completed form to Commission Secretary Prior to start of regular session. Name:. 1-)—<-d tpe,k f� Address: (p -Z- MCAAn Phone:—.0177— 00e -0052-- Date: 5 5 —,?0 I wish to share my views on an Agenda Item: I will speak i, SUPPO T o his item 1 will speak in OP ION of this item I do not wish to speak, but wish to record my SUPPORT/ OPPOSITION Signature: Vh-4VU v` Required..- Cards will not be read into the record unless it is signed, Southlake Planning and Zoning Meeting Public Comment Form Please print. Return com Meted formtoCommission SecretaLy rior to start �o7f�regular session, Address: v7i' C'�il ft9 i ✓ a.' r� r J �—_ ON ifI wish to share my views on an Agenda Item: 016 I will speak in SUPPORT of this item I will speak in OPPOSITION of this iter I do not wish to speak, but wish rD.record my SUPPORT/ OPPOSITION Signature: ! v= Required: Cit ds will not be read into the record k, it is signed. Case No. Attachment D ZA21-0025 Page 8 Response Received from Outside the Notification Area Planning and Zoning Commission Meeting 05/06/2021 • I am concerned that this development will add additional stormwater volumes to the West Jones Creek watershed due to increased runoff from the developed site. I am concerned that even if retention capacity is added to hold peak runoffs at current levels the increased volume of runoff will still cause higher levels of downstream erosion and sediment transport due to the extended drainage times and higher total runoff volume. The inlet and outlets from the ponds at the City of Southlake's Gateway Park are experiencing high levels of erosion and channelization. The channels do not meet design criteria specified in City of Southlake's ordinance ARTICLE II. - STORM DRAINAGE POLICY: Sec. 9.5-61. - Drainage manual reference. (a) Fort Worth Drainage Manual or Sec. 9.5-65. - Miscellaneous design criteria DIVISION 4. - OPEN CHANNEL POLICY See. 9.5-82. - Natural channels or Sec. 9.5-83. - Earth channels. • The Gateway City Park had a walkway and foot bridge that crossed the channel. The bridge was over washed during rains and the foundation eroded until it was declared unsafe. The bridge has been dismantled. The City of Southlake Public Works Department has contracted with TNP to design Erosion Improvements for Southlake Glen to harden the channel and address the erosion that is visible from the park. As directed by the Public Works Department, the TNP design will not be based on hydraulic analysis and will not address channel capacity issues or other areas which have high levels of erosion that are outside the predefined scope. • The drainage channel at the outlet of the North Kimball Ave drainage culvert at approximately STA -30 is also experiencing high levels of erosion. This channel does not meet design criteria specified in City of Southlake's ordinance ARTICLE 11. - STORM DRAINAGE POLICY: Sec. 9.5-61. - Drainage manual reference. (a) Fort Worth Drainage Manual or Set. 9.5-65. - Miscellaneous design criteria DIVISION 4. - OPEN CHANNEL POLICY Sec. 9.5-82. - Natural channels or Sec. 9.5-83. - Earth channels. • Numerous development projects have been approved and completed that add significantly to the Stormwater runoff since the last West Jones Creek watershed modeling/analysis. Last LOMR Feb 15, 2007, Last modeling of West Jones Creek watershed 2008 as part of Gateway Project. The above issues have been documented in a letter to the City on Feb. 22, 2019. No answer has been received to date. An engineering study of the areas noted above is currently being conducted by the Patterson Pond HOA. • Since the current water shed volumes already exceed the capacity of the above-described facilities, in accord with City of Southlake ordinance Article II Storm Drainage Policy an updated regional West Jones Creek drainage study should be completed. Remedies for downstream drainage channels deficiencies should be agreed before this project is approved. • 1 cannot support this development unless a regional downstream study of the West Jones Creek watershed is done and the design deficiencies in the downstream channels are addressed. Signed by: "e% He Hubble 2208 Patterson Way Southlake, Texas 76092 Phone: 817-424-9098 Case No. Attachment D ZA21-0025 Page 9