Item 13 - PlansRE L E A S E RE V DA T E N A M E GOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVING JURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE: CO V E R S H E E T SHEET SHEET TITLE EMAIL: AP N Advanced RE L E A S E RE V DA T E N A M E A D D R E S S AP N GE N E R A L N O T E S A D D R E S S k W P H O T O V O L T A I C P L A N S PROJECT. DISREGARD RE L E A S E RE V DA T E N A M E A D D R E S S AP N 2018 IFC ROOF ACCESS REQUIREMENTS THE FOLLOWING INFORMATION INDICATES THE REQUIRED ROOF TOP SHEET NOTES RE L E A S E RE V DA T E N A M E A D D R E S S * EXISTING ROOF DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RA C K I N G L A Y O U T RACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAIL SHEET NOTES RE L E A S E RE V DA T E N A M E A D D R E S S AP N PV RACKING LEGEND 21SCALE: NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODE REQUIREMENTS AT THE TIME IT WAS BUILT. C. SHEET NOTES RE L E A S E RE V DA T E N A M E A D D R E S S AP N PV RACKING LEGEND * DETAILS IN SECTION OR SIDE VIEW 1. RE L E A S E RE V DA T E N A M E A D D R E S S AP N PV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. RE L E A S E RE V DA T E N A M E A D D R E S S DC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING AMPACITY CHECKCORRECTED AMPACITY CALCULATION TEMPRATING LEGEND RE L E A S E RE V DA T E N A M E A D D R E S S TH R E E L I N E D I A G R A M EQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 3 DC DISCONNECT 4 DC COMBINER BOX 5 JUNCTION BOX 6 RAPID SHUTDOWN 7 AC/DC INVERTER 8 AC/DC INVERTER W/ INTE AC DISC 9 AC DISCONNECT (FUSIBLE) 10 SOLAR LOAD CENTER 11 PROD/GENERATION METER 12 SUB PANEL 13 14 15 EXISTING UTILITY METER NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED TAG AP N A D D R E S S SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS k W P H O T O V O L T A I C P L A N S ELECTRICAL NOTES UNGROUNDED PV SYSTEMS: RE L E A S E RE V DA T E N A M E A D D R E S S AP N ELECTRICAL SYMBOL LEGEND AC DISCONNECT DC DISCONNECT DC COMBINER BOX AUTO TRANSFORMERCB DC AC ATF DCB DC DISCONNECTINGCOMBINER BOX EL E C T R I C A L L A Y O U T EQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES MUST BE CONNECTED TO THE EGC (EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSOR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBS ARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKING SPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2. FOR "LAY-IN" LUG MODULE GROUNDING; CORRECTHARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED,TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BEATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TO BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETAL PARTS THAT MIGHT COME INTO CONTACT WITHCURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THEMETAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS,DISCONNECTS, METERS, JUNCTION BOXES AND COMBINERBOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTSTO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THECONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THESYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT,OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECTCONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING, USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP A D D R E S S k W P H O T O V O L T A I C P L A N S SOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATTINV#DC/AC STRING INVERTER CLP CRITICAL LOADS PANEL SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP PERFORMANCE METER UTILITY METER P M XFMR TRANSFORMER JUNCTION BOXJB RSD RAPID SHUTDOWN SUB-PANELSUB ATS AUTO TRANSFER SWITCH SP INVMAC NORTH PROPOSED UNDERGROUND CONDUIT TRENCH LENGTH 50FT JB JB SUB SCALE: 1/24” = 1’0” @ SHEET SIZE A3QTY 34 MISSION SOLAR MSE345SX5T MODULES QTY 1 SolarEdge SE11400H-US (240V) INVERTER E- 1 0 0 PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER. Cu r r e n t S o l a r L L C . - 30 0 0 A l t a m e s a B l v d , S u i t e 3 0 0 Fo r t W o r t h , t x 7 6 1 3 3 (8 1 7 ) 6 9 0 - 1 4 5 6 11 . 7 3 0 Bu r c h e t t , L a r r y 29 1 0 H a r b o r R e f u g e So u t h l a k e , T X 7 6 0 9 2 02 / 2 3 / 2 0 2 1 SU B M I T F O R P E R M I T 1 03 / 1 5 / 2 0 2 1 ZA 2 1 - 0 0 1 5 R E V I E W O N E RE L E A S E RE V DA T E N A M E A D D R E S S AP N SHEET NOTES1SCALE: 1/2" = 1'-0"CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 2 3 5 6 8 SCALE: 1/4" = 1'-0"9 10 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12" 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PVINVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2. MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICEDISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEMDISCONNECTION MEANS. 3. CODE REFERENCE: NEC 690.56(A)(B), 705.10 4. WHITE LETTERS ON A RED BACKGROUND. 5. MINIMUM OF 7 3/4" x 5" 6. FONT: 3/4" "CAUTION", 1/4" "WARNING", 3/16" HEADER, 1/8" DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEDISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERETHE DISCONNECT IS OPERATED. (IFC 605.11.1.3) RE L E A S E RE V DA T E N A M E A D D R E S S AP N SHEET NOTES 1. 2. 3. 4. COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE 3 2 KN 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com GFT-OP-11a (24-MAR-2014)© 2019 IronRidge, Inc. FlashFoot2 Certification Letter - 1 28357 pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RE L E A S E RE V DA T E N A M E A D D R E S S AP N EQ U I P . C U T S H E E T S A D D R E S S k W P H O T O V O L T A I C P L A N S AC DISCONNECT CUT SHEET R- 1 0 9 Cu r r e n t S o l a r L L C . - 30 0 0 A l t a m e s a B l v d , S u i t e 3 0 0 Fo r t W o r t h , t x 7 6 1 3 3 (8 1 7 ) 6 9 0 - 1 4 5 6 11 . 7 3 0 Bu r c h e t t , L a r r y 29 1 0 H a r b o r R e f u g e So u t h l a k e , T X 7 6 0 9 2 02 / 2 3 / 2 0 2 1 SU B M I T F O R P E R M I T 1 03 / 1 5 / 2 0 2 1 ZA 2 1 - 0 0 1 5 R E V I E W O N E