Loading...
Item 10 - PlansSHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 Project NameSTREET ADDRESSCITY & STATE PV-0 EQUIPMENT SUMMARY SCOPE OF WORK SYSTEM RATING GOVERNING CODES COVER SHEET INDEX 2020 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL FIRE CODE UNDERWRITERS LABORATORIES (UL) STANDARDS OSHA 29 CFR 1910.269 TO INSTALL A SOLAR PHOTOVOLTAIC (PV) SYSTEM AT THE GATES RESIDENCE, LOCATED AT 1211 TIMBER COURT, SOUTHLAKE, TEXAS. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. 18.6 kW DC STC 18.0 kW AC (57)SUNPOWER SPR-E20-327-E-AC PV MODULES (57)SUNPOWER SPR-E20-327-E-AC [240V] PV INVERTERS (452)(42 X 10.75') LINEAR FEET SUNPOWER INVISIMOUNT PROJECT LOCATION VICINITY MAP PV-0 COVER PV-1 SITE MAP AND PV LAYOUT PV-2 STRING MAP AND MONITORING LAYOUT PV-3 ELECTRICAL DIAGRAM PV-4 EQ WALL & MOUNTING DETAIL PV-5 SYSTEM LABELING DETAIL PV-6 SAFETY PLAN PV Installation Professional Mark McManus Cert #PV-042118-020534 ONCOR REVENUE METER #147 630 683 ESID #10443720002664515 NEW FEED-THROUGH PANEL SOLAR LOAD CENTER MONITORING PV AC DISCONNECT - VISIBLE BREAK - LOCKABLE - LABELED - LOCATED WITHIN 10' OF ONCOR REVENUE METERGROUNDING ELECTRODE MAIN DISTRIBUTION PANEL#2 -INSIDE GARAGE GROUNDING ELECTRODE MAIN DISTRIBUTION PANEL#3 3'-0" 1 ' - 6 " 1'- 6 " 1 ' - 6 " 3'-0" 3'-0" 1' - 6 " 3'-0" FIRE CODE SETBACK PER IFC 1204.2.1 PV ARRAY #1 (32) MODULES PV ARRAY #2 (7) MODULES GROUNDING ELECTRODE MAIN DISTRIBUTION PANEL#1 -INSIDE HOUSE (E) EXISTING DETACHED STRUCTURE SUNPOWER INVISIMOUNT RAIL (TYP.) RAFTER (TYP.) ON 24" CENTERS SPCR-CH ROOF ATTACHMENT (TYP.) SUNPOWER PV MODULE (TYP.) DETAIL: PV ARRAY #3 (18) MODULES SOLAR LOAD CENTER PV AC DISCONNECT -VISIBLE BREAK -LOCKABLE -LABELED -LOCATED WITHIN 50' OF ONCOR REVENUE METER SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 PV-1 SITE MAP & PV LAYOUT CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.) TYP. ROOF ATTACHMENT SPACING SHALL BE 6'-0" MAX FOR LAG BOLT TYPE ROOF ATTACHMENTS ANCHORED TO RAFTERS 5.) TYP. ROOF ATTACHMENT SPACING SHALL BE 4'-6" MAX FOR S-5! CLAMPS ANCHORED TO STANDING SEAM ROOF PANELS CONSTRUCTION SUMMARY (57)(SUNPOWER SPR-E20-327-E-AC) SOLAR MODULES, 18.6 kW DC STC MODULE DIMENSIONS = 41.2" X 61.3" X 1.80" (57)SUNPOWER SPR-E20-327-E-AC [240V] PV INVERTERS COMBINED INVERTER OUTPUT = 18.0 kW AC. (420)(39 X 10.75') LINEAR FEET SUNPOWER INVISIMOUNT (108)SPCR-CH ROOF ATTACHMENTS 38723LEAD ID: (1)SUNPOWER MONITORING SITE DETAILS ROOF TYPE: ASPHALT SHINGLE ARRAY #1 - TILT = 24°, AZIMUTH = 178° ARRAY #2 - TILT = 24°, AZIMUTH = 178° ARRAY #3 - TILT = 24°, AZIMUTH = 178° UTILITY CONTROLLED OUTAGE REQUIRED TO INSTALL NEW EXTERIOR EATON CH8B200RF FEED-THROUGH PANEL WITH CSR2200N MBK. -MOVING FEEDER BREAKERS TO GARAGE (100A) & GUEST HOUSE (125A) SUB PANELS TO THE NEW FEEDTHROUGH PANEL. -(2) SEPARATE EQ WALLS. PV Installation Professional Mark McManus Cert #PV-042118-020534 PV-2 STRING MAP & MONITORING LAYOUT SUNPOWER SUPERVISOR S/N____________________________ SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 PV Installation Professional Mark McManus Cert #PV-042118-020534 PV-2A STRING MAP & MONITORING LAYOUT SUNPOWER SUPERVISOR S/N____________________________ SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 PV Installation Professional Mark McManus Cert #PV-042118-020534 (8) AWG #10 THWN-2 (1) AWG #8 THWN-2 GND IN 3/4" CONDUIT SUNPOWER MONITORING 20A 20A 20A JUNCTION BOX: TRANSITION FROM DG CABLE TO AWG #10 THWN-2 NEMA 3R, UL LISTED SOLAR LOAD CENTER #1 240 VAC, 125A NEMA 3R, UL LISTED (5) 2P-20A BREAKERS 7 MODULES 10 MODULES BRANCH #3 BRANCH #4 SOLAR ARRAY - 12.8kW DC STC (39) (SUNPOWER SPR-E20-327-E-AC) MODULES (39) (SUNPOWER SPR E20-327-E-AC [240] ) INVERTERS 240VAC, 1.31A MAX CEC WEIGHTED EFFICIENCY 97.5% NEMA 4R, UL LISTED, INTERNAL GFDI (3) AWG #6 THWN-2 (1) AWG #8 THWN-2 GND IN 1" CONDUIT EXISTING GROUNDING ELECTRODE SYSTEM ONCOR REVENUE METER #147 630 683 ESID #10443720002664515 1-PHASE, 240V NEW FEED-THROUGH PANEL EATON CH8B200RF (UPGRADE) 1P3W, 240V, 225A BUS M PV AC DISCONNECT #1 240VAC, 100A FUSIBLE, WITH (2) 70A FUSES NEMA 3R, UL LISTED VISIBLE, LOCKABLE, LABELED WITHIN 10' OF THE ONCOR REVENUE METER 200A 70A MAIN SERVICE DISCONNECT 240V, 200A POINT OF INTERCONNECTION PER NEC 240.21(B)(1) -OR- 705.31 LENGTH OF TAP CONDUCTORS SHALL NOT EXCEED 10 FT FROM POINT OF INTERCONNECT TO OCPD (4) AWG #10 THWN-2 (1) AWG #8 THWN-2 GND IN 3/4" CONDUIT 20A 20A JUNCTION BOX: TRANSITION FROM DG CABLE TO AWG #10 THWN-2 NEMA 3R, UL LISTED SOLAR LOAD CENTER #2 240 VAC, 125A NEMA 3R, UL LISTED (2) 2P-20A BREAKERS 9 MODULES 9 MODULES BRANCH #1 BRANCH #2 SOLAR ARRAY - 5.89kW DC STC (18) (SUNPOWER SPR-E20-327-E-AC) MODULES (14) (SUNPOWER SPR E20-327-E-AC [240] ) INVERTERS 240VAC, 1.31A MAX CEC WEIGHTED EFFICIENCY 97.5% NEMA 4R, UL LISTED, INTERNAL GFDI EXISTING GROUNDING ELECTRODE SYSTEM EXISTING GARAGE PANEL GE, 1P3W, 240V, 125A BUS 100A 100A FEEDER BREAKER POINT OF INTERCONNECTION PER NEC 240.21(B)(1) -OR- 705.31 LENGTH OF TAP CONDUCTORS SHALL NOT EXCEED 10 FT FROM POINT OF INTERCONNECT TO OCPD PV AC DISCONNECT #2 240VAC, 60A FUSIBLE, WITH (2) 40A FUSES NEMA 3R, UL LISTED VISIBLE, LOCKABLE, LABELED WITHIN 50' OF THE ONCOR REVENUE METER (4) AWG #6 THWN-2 (1) AWG #8 THWN-2 GND IN 1" CONDUIT (3) AWG 2/0 CU THWN-2 (1) AWG #6 THWN-2 GND IN 2" CONDUIT EXISTING WIRES 11 MODULES BRANCH #2 11 MODULES BRANCH #1 20A 20A 40A EXISTING MAIN DISTRIBUTION PANEL GE,1P3W 240V, 200A BUS -INSIDE HOUSE 125A TO GUEST HOUSE 100A (3) AWG 2/0 CU THWN-2 IN 2" CONDUIT SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 PV-3 ELECTRICAL DIAGRAM UTILITY CONTROLLED OUTAGE REQUIRED TO INSTALL NEW EXTERIOR EATON CH8B200RF FEED-THROUGH PANEL WITH CSR2200N MBK. -MOVING FEEDER BREAKERS TO GARAGE (100A) & GUEST HOUSE (125A) SUB PANELS TO THE NEW FEEDTHROUGH PANEL. -(2) SEPARATE EQ WALLS. PV Installation Professional Mark McManus Cert #PV-042118-020534 SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 ELECTRICAL NOTES PV-3A ELECTRICAL DIAGRAM 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90°C WET ENVIRONMENT UNLESS OTHERWISE NOTED. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MAXIMUM MOUNTING HEIGHT FROM GRADE TO CENTER OF METER SOCKET SHALL BE 72" FOR RESIDENTIAL SINGLE PHASE METER SOCKETS 0-320 AMPS. MINIMUM MOUNTING HEIGHT IS 30" FROM FOR AUSTIN ENERGY, AND 48" FOR ALL OTHER JURISDICTIONS 9.) MINIMUM HORIZONTAL CLEARANCE FROM GAS REGULATOR TO ANY ELECTRICAL ENCLOSURE IS 36", EXCEPT AUSTIN ENERGY WHICH REQUIRES 48" CLEARANCE FROM GAS TO METER SOCKET 10.) PV DISCONNECT SHALL BE VISIBLE, LOCKABLE AND LABELED AND THE DOOR CANNOT BE OPENED WHEN HANDLE IS IN ON POSITION 11.) BY DEFAULT THE MONITORING DEVICE IS SHOWN CONNECTED TO A 20-AMP BREAKER IN THE SOLAR LOAD CENTER. ALTERNATIVELY, THE MONITORING DEVICE MAY BE CONNECTED TO A 20-AMP BREAKER AT THE MAIN DISTRIBUTION PANEL. CALCULATIONS FOR CURRENT CARRYING CONDUCTORS CALCULATIONS FOR OVERCURRENT DEVICES CALCULATIONS FOR CURRENT CARRYING CONDUCTORS CALCULATIONS FOR OVERCURRENT DEVICES INVERTER OUTPUT WIRE AMPACITY CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) MAXIMUM INVERTER BRANCH CURRENT = (12)(1.31A) = 15.7A CONTINUOUS USE: #10 WIRE 75°C DERATED AMPACITY = (0.80)(35.0A) = 28.0A 28.0A > 15.7A CONDITIONS OF USE: #10 WIRE 90°C DERATED AMPACITY = (0.91)(0.80)(40.0A) = 29.1A 29.1A > 15.7A SOLAR LOAD CENTER OUTPUT WIRE AMPACITY CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) COMBINED CURRENT = (18)(1.31A) = 23.6A CONTINUOUS USE: #6 WIRE 75°C DERATED AMPACITY = (0.80)(65A) = 52.0A 52.0 > 23.6A CONDITIONS OF USE: #6 WIRE 90°C DERATED AMPACITY = (0.91)(75A) = 68.3A 68.3A > 23.6A INVERTER BRANCH AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) MAXIMUM BRANCH INVERTER CURRENT = (12)(1.31A) = 15.7A MINIMUM OCPD = (15.7A)(1.25) = 19.6A USE 2P-20A BREAKERS IN SOLAR LOAD CENTER FOR INVERTER BRANCH OCPD SYSTEM AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) COMBINED CURRENT = (18)(1.45A) = 23.6A MINIMUM OCPD = (23.6A)(1.25) = 29.5A USE (2) 40A FUSES IN PV AC DISCONNECT FOR SYSTEM OCPD NOTE: AWG #6 CONDUCTORS ARE ADEQUATELY PROTECTED BY 40A FUSES MAIN HOUSE ELECTRICAL CALCULATION:- GARAGE ELECTRICAL CALCULATION:- INVERTER OUTPUT WIRE AMPACITY CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) MAXIMUM INVERTER BRANCH CURRENT = (12)(1.31A) = 15.7A CONTINUOUS USE: #10 WIRE 75°C DERATED AMPACITY = (0.80)(35.0A) = 28.0A 28.0A > 15.7A CONDITIONS OF USE: #10 WIRE 90°C DERATED AMPACITY = (0.91)(0.7)(40.0A) = 25.5 25.5 15.7A SOLAR LOAD CENTER OUTPUT WIRE AMPACITY CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) COMBINED CURRENT = (39)(1.31A) = 51.1A CONTINUOUS USE: #6 WIRE 75°C DERATED AMPACITY = (0.80)(65A) = 51.1A 52.0A > 51.1A CONDITIONS OF USE: #6 WIRE 90°C DERATED AMPACITY = (0.91)(75A) = 68.3A 68.3A > 51.1A INVERTER BRANCH AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) MAXIMUM BRANCH INVERTER CURRENT = (12)(1.31A) = 15.7A MINIMUM OCPD = (15.7A)(1.25) = 19.6A USE 2P-20A BREAKERS IN SOLAR LOAD CENTER FOR INVERTER BRANCH OCPD SYSTEM AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC [240V]) COMBINED CURRENT = (39)(1.31A) = 51.1A MINIMUM OCPD = (51.1A)(1.25) = 63.9A USE (2) 70A FUSES IN PV AC DISCONNECT FOR SYSTEM OCPD NOTE: AWG #6 CONDUCTORS ARE ADEQUATELY PROTECTED BY 70A FUSES PV Installation Professional Mark McManus Cert #PV-042118-020534 P V - 4 E Q . W A L L & M O U N T I N G D E T A I L E Q U I P M E N T E L E V A T I O N 1 N T S M O U N T I N G D E T A I L 3 N T S MOUNTING METHOD2NTS PV MODULE(E) COMPOSITE SHING L E R O O F 2X6 RAFTERS @ 24" OC SEE (3/PV4 - EQWALL) FORENLARGEDVIEW 2 X 6 R A F T E R S @ 2 4 " O C 5 / 1 6 " x 3 " S S L A G B O L T W I T H M I N 2 1 2 " T H R E A D E M B E D M E N T , S E A L E D P E N E T R A T I O N I N T O R A F T E R S S U N P O W E R I N V I S I M O U N T R A I L P V M O D U L E G R O U N D I N G E N D / M I D C L A M P A L U M N . " L " B R A C K E T W / 3 / 8 " S S B O L T & N U T S U N P O W E R F L A S H I N G , 1 2 " x 1 2 " x 0 . 0 5 0 " , 5 0 5 0 , M I L L C O M P O S I T E S H I N G L E R O O F S H E E T N U M B E R D E S I G N B Y : A D E S I G N P A C K E T R E V D A T E R E V I S I O N S D E S C R I P T I O N C O N T R A C T O R F R E E D O M S O L A R L L C 4 8 0 1 F R E I D R I C H L N , S T E 1 0 0 A U S T I N , T X 7 8 7 4 4 T E C L # 2 8 6 2 1 T B P E F I R M # F - 1 7 6 9 0 P R O J E C T N A M E S H E E T S I Z E A N S I B 1 1 " x 1 7 " S H E E T N A M E GATES, TYLER 1211 TIMBER COURT SOUTHLAKE, TEXAS, 76092 (214) 725-4051 0 1 / 3 0 / 2 0 2 1 F R E E D O M S O L A R , L L C B D E S I G N P A C K E T 0 3 / 1 6 / 2 0 2 1 NEW F E E D - T H R O U G H P A N E L - O U T S I D E H O U S E W A L L - POINT O F I N T E R C O N N E C T I O N P V A C D I S C O N N E C T # 1 S O L A R L O A D C E N T E R # 1 M O N I T O R I N G O N C O R R E V E N U E M E T E R F R O M P V A R R A Y MAIN DISTRIBUTION PANEL#2- INSIDE GARAGE WALL MAIN DISTRIBUTIO N P A N E L # 1 - INSIDE MAIN HO U S E W A L L PV AC DISCONNECT #2SOLAR LOAD CENTER #2FROM PV ARRAY P V I n s t a l l a t i o n P r o f e s s i o n a l M a r k M c M a n u s C e r t # P V - 0 4 2 1 1 8 - 0 2 0 5 3 4 SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 > RED BACKGROUND > WHITE LETTERING > MIN. 3/8" LETTER HEIGHT > ALL CAPITAL LETTERS > ARIAL OR SIMILAR FONT > REFLECTIVE, WEATHER RESISTANT MATERIAL, UL 969 SIGNAGE REQUIREMENTSNOTE: NOT ALL LABELS MAY BE APPLICABLE WARNING: PHOTOVOLTAIC POWER SOURCE REQ'D BY: NEC 690.13(B)B REQ' BY: AHJ E REQ'D BY: AHJ APPLY TO: REVENUE METER SOCKET (IF APPLICABLE) F 2" ADDRESS NUMBERS REQ'D BY: NEC 705.12(B)(2)(3)(b)D WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. REQ'D BY: NEC 690.13(B) APPLY TO: PV DISCONNECT APPLY TO: REVENUE METER SOCKET (IF APPLICABLE) WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE APPLY TO: DISTRIBUTION EQUIPMENT ADJACENT TO BACK-FED BREAKER A APPLY TO: PV DISCONNECT REVENUE METER REQ'D BY: FREEDOM SOLAR G APPLY TO: MONITORING DEVICE ENCLOSURE MONITORING APPLY TO: PV DISCONNECT HREQ'D BY: 690.56(1)(a) PV SYSTEM DISCONNECT APPLY TO: RACEWAYS, CABLE TRAYS, OTHER WIRING METHODS, AND ENCLOSURES THAN CONTAIN PV SYSTEM DC CONDUCTORS REQ'D BY: NEC 690.31(G)(3)C APPLY TO: MAIN DISTRIBUTION PANEL IREQ'D BY: FREEDOM SOLAR SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT: 74.7 A OPERATING VOLTAGE: 240 VAC PV-5 SYSTEM LABELING DETAIL PV Installation Professional Mark McManus Cert #PV-042118-020534 DR I V E W A Y TIMBER COURT SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME GA T E S , T Y L E R 12 1 1 T I M B E R C O U R T SO U T H L A K E , T E X A S , 7 6 0 9 2 (2 1 4 ) 7 2 5 - 4 0 5 1 01/30/2021 FREEDOM SOLAR, LLC BDESIGN PACKET 03/16/2021 PV-6 SAFETY PLAN DRAW IN CONTROLLED ACCESS ZONE (CAZ) BOUNDARY AND LADDER PLACEMENT ON SITE PLAN BELOW. HARD HAT IS REQUIRED AT ALL TIMES IN CAZ CONDUCT SAFETY MEETING WITH ALL CREW MEMBERS ON SITE AT THE BEGINNING OF EACH JOB. USE SIGN IN SHEET BELOW. 1. _________________________________________ 2. _________________________________________ 3. _________________________________________ 4. _________________________________________ 5. _________________________________________ GUEST SIGN IN 1. _________________________________________ 2. _________________________________________ 3. _________________________________________COMPETENT PERSON: ___________________________ JOB START DATE: _________________ PV InstallationProfessionalMark McManus Cert #PV-042118-020534 Datasheet SunPower® E-Series: E20-327 | E19-320 SunPower® Residential AC Module Built specifically for use with the SunPower Equinox™ system, the only fully integrated solution designed, engineered, and warranted by one manufacturer. Maximum Power. Minimalist Design. Industry-leading efficiency means more power and savings per available space. With fewer modules required and hidden microinverters, less is truly more. Highest Lifetime Energy and Savings. Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.1 150% 140% 130% 120% 110% 100% 90% 80% 70% 60% 0 5 10 15 20 25 Years of operation Up to 60% more lifetime energy Best Reliability. Best Warranty. With more than 25 million modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. 100% 98% 96% 94% 92% 90% 88% 86% 84% 82% 80% 0 5 10 15 20 25 Years of operation 12% more power in year 25 E-Series and X-Series And Better. The SunPower® Maxeon® Solar Cell •Enables highest-efficiency modules available. 2 •Unmatched reliability 3 •Patented solid metal foundation prevents breakage and corrosion Factory-integrated Microinverter •Simpler, faster installation •Integrated wire management, rapid shutdown •Engineered and calibrated by SunPower for SunPower modules Wa r r a n t e d m o d u l e p o w e r 25 - y ea r e n e r gy y ie l d p er W sunpower.com E-Series: E20-327 | E19-320 SunPower® Residential AC Module AC Electrical Data IInverter Model: Enphase IQ 7XS ((IQ7XS--996--AACM--UUS) @@240 VAC @208 VAC Peak Output Power 320 VA 320 VA Max. Continuous Output Power 315 VA 315 VA Nom. (L–L) Voltage/Range2 (V) 240 / 211–264 208 / 183–229 Max. Continuous Output Current (A) 1.31 1.51 Max. Units per 20 A (LL) Branch Circuit3 12 (single phase) 10 (two pole) wye CEC Weighted Efficiency 97.5% 97.0% Nom. Frequency 60 Hz Extended Frequency Range 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 5.8 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor (adjustable) 0.7 lead. / 0.7 lag. No active phase balancing for three-phase installations 1 SunPower 360 W compared to a conventional module on same-sized arrays (260 W, 16% efficient, approx. 1.6 m2), 4% more energy per watt (based on third-party module characterization and PVSim), 0.75%/yr slower degradation (Campeau, Z. et al. “SunPower Module Degradation Rate,” SunPower white paper, 2013). 2 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of January 2017. 3 #1 rank in “Fraunhofer PV Durability Initiative for Solar Modules: Part 3.” PVTech Power Magazine, 2015. Campeau, Z. et al. “SunPower Module Degradation Rate,” SunPower white paper, 2013. 4 Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide #518101 for more information. 5 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. See www.sunpower.com/facts for more reference information. For more details, see extended datasheet www.sunpower.com/datasheets Specifications included in this datasheet are subject to change without notice. ©2018 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo and MAXEON are registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. Please read the Safety and Installation Instructions for details. 531948 RevA DC Power Data SPR-E20-327-E-AC SPR-E19-320-E-AC Nom. Power 5 (Pnom) 327 W 320 W Power Tol. ȫ ȫ Module Efficiency 20.4% 19.9% Temp. Coef. (Power) ȫ0.35%/°C ȫ0.35%/°C Shade Tol. •Three bypass diodes •Integrated module-level maximum power point tracking Tested Operating Conditions Operating Temp. ȫr)WRr) ȫr&WRrC) Max. Ambient Temp. 122°F (50°C) Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m² front & back Snow: 125 psf, 6000 Pa, 611 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 96 Monocrystalline Maxeon Gen III Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 42.9 lbs (19.5 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1703 • UL 1741 / IEEE-1547 • UL 1741 AC Module (Type 2 fire rated) • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA) 4 (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment 6 Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with InvisiMount racking and InvisiMount accessories (UL 2703): • Module grounding and bonding through InvisiMount • Class A fire rated When used with AC module Q Cables and accessories (UL 6703 and UL 2238)6 : • Rated for load break disconnect PID Test Potential-induced degradation free Improve Support, Reduce Maintenance Costs An intuitive monitoring website enables you to: • See a visual map of customer sites • Remotely manage hundreds of sites • Receive elective system reports • Locate system issues and remotely diagnose • Diagnose issues online • Drill down for the status of individual devices Add Value for Customers With the SunPower Monitoring System customers can: • See what their solar system produces each day, month, or year • Optimize their solar investment and save on energy expenses • See their energy use and estimated bill savings • See their solar system’s performance using the SunPower monitoring website or mobile app SunPower EnergyLink—Plug-and-Play Installation This complete solution for residential and commercial monitoring and control includes the SunPower® PV Supervisor 6 (PVS6) which improves the installation process, overall system reliability, and customer experience. • Compact footprint for improved aesthetics • Robust cloud connectivity and comprehensive local connectivity • Flexible configuration of devices during installation • Consumption metering • Revenue-grade production metering (pending) • Web-based commissioning • Remote diagnostics of PVS6 and inverters • Durable UL Type 3R enclosure reduces maintenance costs •Easy integration with SunPower eBOS Robust Cloud Connectivity Multiple options to maintain optimal connectivity: •Hardwired Ethernet •Wi-Fi • Cellular backup SunPower Monitoring Websites PVS6 SunPower AC Modules Multiple communication options include Ethernet, Wi-Fi, and cellular. 530536 RevC SunPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates consistent, even module spacing • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs ȏ 'HVLJQLQODQGVFDSHDQGSRUWUDLWZLWKXSWRɒ rail span • Pre-drilled rails and rail splice • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics ȏ 3UHPLXPORZSURȴOHGHVLJQ • Black anodized components ȏ +LGGHQPLGFODPSVDQGFDSSHGȵXVK end clamps Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Optional URRIWRSWUDQVLWLRQȵDVKLQJUDLO mounted J-box, and wire management rail clips • Combine with SunPower modules and SunPower EnergyLink® monitoring app sunpower.com Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster LQVWDOODWLRQWLPHGHVLJQȵH[LELOLW\DQGVXSHULRUDHVWKHWLFV 7KHΖQYLVL0RXQWSURGXFWZDVVSHFLȴFDOO\HQYLVLRQHGDQG engineered to pair with SunPower modules. The resulting V\VWHPOHYHODSSURDFKDPSOLȴHVWKHDHVWKHWLFDQG LQVWDOODWLRQEHQHȴWVȃIRUKRPHRZQHUVDQGIRULQVWDOOHUV Datasheet SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Mid clamp Black oxide stainless steel 300 series 63 g (2.2 oz) End clamp Black anodized aluminum 6000 series 110 g (3.88 oz) Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) Rail splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) Rail bolt M10-1.5 × 25 mm; custom T-head SS304 18 g (0.63 oz) Rail nut M10-1.5; DIN 6923 SS304 nominal Ground lug assembly SS304; A2-70 bolt; tin-plated copper lug 106.5 g (3.75 oz) Row-to-row grounding clip SS 301 with SS 304 M6 bolts 75 g (2.6 oz) Row-to-row spacer Black POM-grade plastic 5 g (0.18 oz) Roof Attachment Hardware Supported by Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal interface for other roof attachments InvisiMount Operating Conditions Temperature ȫr&WRr& ȫr)WRr) Max. Load (LRFD)• 3000 Pa uplift • 6000 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation. ΖQYLVL0RXQW:DUUDQWLHV$QG&HUWLȴFDWLRQV Warranties • 25-year product warranty • \HDUȴQLVKZDUUDQW\ &HUWLȴFDWLRQV • UL 2703 Listed • Class A Fire Rated © 2018 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. $OORWKHUWUDGHPDUNVDUHWKHSURSHUW\RIWKHLUUHVSHFWLYHRZQHUV6SHFLȴFDWLRQVLQFOXGHGLQWKLVGDWDVKHHWDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH InvisiMount Components Module¹ / Mid Clamp and Rail Mid Clamp End Clamp Rail and Rail Splice Ground Lug Assembly Module¹ / End Clamp and Rail sunpower.com 509506 RevF ² SunPower recommends that all Equinox™, InvisiMount™, and AC module systems always be designed using the InvisiMount Span Tables #524734. If a designer decides to instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed Professional Engineer (PE) must then stamp all calculations. If you have any questions please contact SunPower Technical Support at 1-855-977-7867. InvisiMount Component LRFD Capacities² Mid clamp Uplift 664 lbf Shear 540 lbf End clamp Uplift 899 lbf Shear 220 lbf Rail Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft Rail splice Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft L-foot Uplift 1000 lbf Shear 390 lbf Datasheet ¹ Module frame that is compatible with the InvisiMount system required for hardware interoperability. Row-to-Row Spacer Row-to-Row Grounding Clip COMP MOUNT – BLACK Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 T: 510.730.1343 www.pegasussolar.com Manufactured with advanced materials and coating to outlast the roof itself Tested to AC286 without sealant 0.9" elevated water seal Fully IBC/CBC Code Compliant Exceeds ASCE 7-10 Standards Flashings, L-Feet and SS lags with bonded EPDM washers are included in each 24-pack 25-year Warranty Superior Waterproong Code Compliant All-In-One Kit Packaging WATERTIGHT FOR LIFE Pegasus Solar's Comp Mount is a cost effective, high-quality option for rail installations on composition shingle roofs. Designed to last decades, the one-piece flashing with elevated cone means there is simply nothing to fail. A BETTER DAY ON THE JOB Simple 3-piece design for rapid installation One-piece flashing with elevated cone – No press-fits or deck-level EPDM washers to fail Encapsulating design raises the water seal 0.9" above roof deck Black Comp Mount Install Kits PSCR-C0 PSCR-UBB0 SPCR-CH L-Foot Type COMP MOUNT – BLACK Closed Slot Closed SlotOpen Slot Kit Contents SKU Patents Pending. All rights reserved. 2019 Pegasus Solar Inc Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 T: 510.730.1343 www.pegasussolar.com 1. Drill pilot hole in center of rafter. 3. Place L-Foot over cone and install lag with washer through L-Foot. 2. Optional: Apply a "U-shape" of sealant to underside of flashing and postition under 2nd shingle course, cone over pilot hole. 4. Drive lag to required depth. Attach rail per rail manufacturer's instructions. L-Foot, Flashing, 5/16" x 4-1/2" SS Lag w/ EPDM washer L-Foot, Flashing, 5/16" x 4-1/2" SS Lag w/ EPDM washer L-Foot, Flashing, 5/16" x 4-1/2" SS Lag w/ EPDM washer, M10 Hex Bolt Black L-Foot and Black Flashing Most Composition Shingle IBC, ASCE/SEI 7-10, AC286 Railed Systems Painted Galvalume Plus Aluminum 24 72Boxes per Pallet Kit Quantity L-Foot Material Flashing Material Compatible Rail Install Application Certifications Roof Type Finish pe.eaton.com Eaton general duty cartridge fuse safety switch DG222NRB UPC:782113144221 Dimensions: Height:14.37 IN● Length:7.35 IN● Width:8.4 IN● Weight:10 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. ● Specifications: Type:General duty, cartridge fused● Amperage Rating:60A● Enclosure:NEMA 3R● Enclosure Material:Painted galvanized steel● Fuse Class Provision:Class H fuses● Fuse Configuration:Fusible with neutral● Number Of Poles:Two-pole● Number Of Wires:Three-wire● Product Category:General duty safety switch● Voltage Rating:240V● Supporting documents: Eatons Volume 2-Commercial Distribution● Eaton Specification Sheet - DG222NRB● Certifications: UL Listed● Product compliance:No Data pe.eaton.com Eaton general duty non-fusible safety switch DG222URB UPC:782113144238 Dimensions: Height:14.38 IN● Length:7.38 IN● Width:8.69 IN● Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. ● Specifications: Type:Non-fusible, single-throw● Amperage Rating:60A● Enclosure:NEMA 3R, Rainproof● Enclosure Material:Painted galvanized steel● Fuse Configuration:Non-fusible● Number Of Poles:Two-pole● Number Of Wires:Two-wire● Product Category:General duty safety switch● Voltage Rating:240V● Supporting documents: Eatons Volume 2-Commercial Distribution● Eaton Specification Sheet - DG222URB● Certifications: UL Listed● Product compliance:No Data pe.eaton.com Eaton CH main lug loadcenter CH8L125RP UPC:782114190548 Dimensions: Height:3.69 IN● Length:13 IN● Width:11 IN● Weight:12 LB Notes:Ground bar kits priced separately. Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Warranties: Limited lifetime● Specifications: Special Features:Cover included● Type:Main lug only● Amperage Rating:125A● Box Size:7r● Bus Material:Copper● Enclosure:NEMA 3R● Enclosure Material:Metallic● Feed Type:Overhead● Main Circuit Breaker:CH● Number Of Circuits:8● Number Of Wires:Three-wire● Phase:Single-phase● Voltage Rating:120/240V, 208Y/120, 240V● Wire Size:#6-1/0 AWG● Supporting documents: Type CH Circuit Breakers and Loadcenters● Loadcenters and Circuit Breakers● Eatons Volume 1-Residential and Light Commercial ● pe.eaton.com Eaton CH main lug loadcenter CH12L125R UPC:782113097381 Dimensions: Height:5.19 IN● Length:16.75 IN● Width:14.31 IN● Weight:15.8 LB Notes:Suitable for use as service equipment when not more than six service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Rainproof panels are furnished with hub closure plates. For rainproof hubs. Warranties: Limited lifetime● Specifications: Special Features:Cover included● Type:Main lug only● Amperage Rating:125A● Box Size:B● Bus Material:Copper● Enclosure:NEMA 3R● Enclosure Material:Metallic● Feed Type:Overhead● Main Circuit Breaker:CH● Number Of Circuits:12● Number Of Wires:Three-wire● Phase:Single-phase● Voltage Rating:120/240V● Wire Size:#6-2/0 AWG● Supporting documents: Dimensional Drawing - CH 3/4 LOADCENTER, MAIN LUG ONLY, OUTDOOR NEMA 3R, 120/240 VAC, 1 PH ● 4.2" 7 3/8" 6 7/16" 4" Junction Box 6 x 6 x 4 Drawn By: O.M.Date: 6/19/17 6" 6" 0.220" 6 7/16" 6 3/4" 6 3/4" 0.180"0.350" Gasket (Top View) Gasket (Side View) Lid (Top View) Lid (Side View) Box (Top View) Box (Side View) 1/8" R 3/16 R 1/4 5133710 1/2"# 8 by UL Listed Marine Listed UL File # E205935 (QCUP) UL Control # 92CM Material is Rigid PVC 132 cu in Volume (2163 cu cm) Screws are Zinc Plated Steel Gasket is neoprene