Item 6A - PlansABBREVIATIONS ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET —BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT LICENSE TYPE EC # 33536 MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Southlake City 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER —CONDITIONING INVERTER. 2. A NATIONALLY — RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 3. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 4. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL — LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH THE 2018 IBC AND 2018 IRC. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2020 NATIONAL ELECTRIC CODE. VICINITY MAP INDEX Sheet 1 COVER SHEET + Sheet 2 PROPERTY PLAN Sheet 3 SITE PLAN r Sheet 4 STRUCTURAL VIEWS Sheet 5 UPLIFT CALCULATIONS 4 Sheet 6 THREE LINE DIAGRAM Fes. Sheet 7 THREE LINE DIAGRAM CONT. � L Sheet 8 Cutsheets PHOTOSHOP Attached REV BY DATE COMMENTS REV A I OOC 1 8/13/2020 OFFSET DECREASE, SETBACKS, CORRECTIONS UTILITY: Oncor (MP2 Energy —Dallas) echnologies, U.S. Geological Survey., USDA Farm Serv�ce A ency J B— 7 6 0 4 2 7 3 00 CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER: Barry Smith 12.58 KW PV ARRAY 1 CONTAINED SHALL NOT E USED FOR THE David Bor'a Jimenez T � S L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING C SYSTEM: 81 KWH ENERGY STORAGE SYSTEM SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 wFlashing—Insert 1500 Bent Creek Dr PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES: Southlake TX 76092 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (37) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Delta Electronics # M8—TL—US [240VI 9728220934 COVER SHEET 1 d 12/17/2020 ur- POOL ZZ PROPERTY PLAN N Scale:l" = 30'-0' W E 0 30' 60' S CONJ B- 7 6 0 42 7 3 00 CUSTOMER: DESCRIPTION: DESIGN: CONTTAINEDAINED ALSHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borja Jimenez = 5 L n THE INFORMATION HEREIN JOB NUMBER: BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN zS comp V4 w Flashing —Insert 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS IMODULES: Southlake TX 76092 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (37) Hanwho Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Delta Electronics # MB—TL—US [240V1 9728220934 PROPERTY PLAN 2 d 12/17/2020 METER IS WITHIN 10 FEET FROM THE AC DISCONNECT THE VISIBLE LOCKABLE LABELED DISCONNECT IS LOCATED WITHIN 10 FT. OF ONCOR METER NO MODULES VISIBLE FROM THE STREET Front Of House PRODUCTION: 13965 kWh EFFICIENCY: 1110.11 kWh OFFSET: 62% MP1 ARRAY SQFT: 236' MP2 ARRAY SQFT: 196' MP3 ARRAY SQFT: 118' MP4 ARRAY SQFT: 59' MP8 ARRAY SQFT:118' 0 0 �S (E) DRIVEWAY SITE PLAN N Scale:1/16" = 1' W E 01, 16' 32' lic Mom s CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: JB-7604273 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (37) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 INVERTER: Delta Electronics # M8—TL—US [240V] PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH:338 ARRAY AZIMUTH:338 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 24 ARRAY PITCH: 24 MP2 AZIMUTH:68 ARRAY AZIMUTH:68 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 24 ARRAY PITCH: 24 MP3 AZIMUTH:68 ARRAY AZIMUTH:68 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 24 ARRAY PITCH: 24 MP4 AZIMUTH:68 ARRAY AZIMUTH:68 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 24 ARRAY PITCH: 24 MP8 AZIMUTH:68 ARRAY AZIMUTH:68 MATERIAL: Comp Shinqle STORY: 2 Stories O (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS RELA AUTOMATIC RELAY DC I DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS Ess ENERGY STORAGE SYSTEM FOR STAND H ALONE OPERATION FD DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER RSD RAPID SHUTDOWN 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED r, l( 'I INTERIOR EQUIPMENT IS DASHED L ='J TOTAL ARRAY AREA (SF): 728 TOTAL ROOF AREA (SF): 5814 TOTAL ARRAY AREA IS a 12.52 PERCENT OF TOTAL ROOF AREA Barry Smith 12.58 KW PV ARRAY David Borja Jimenez 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM Southlake, TX 76092 PAGE NAME: SHEET: REV: DATE: 9728220934 SITE PLAN 3 d 12/17/2020 T = 5 Ln (N) Pb PV MODULE 5/16"x1.5" BOLT WI1 5/16" FLAT WASHE ZEP LEVELING F00- ZEP ARRAY SKIR- ZEP MOUNTING BLOCM ZEP FLASHING INSER' (E) COMP. SHINGLE (E) ROOF DECKIN( 5/16" DIA STAINLESS STEEL LAG SCREW (2-1 /2" EMBED, MIN) (E) RAFTER cI T I''lI.Hf V L J1VC V1CVV C J V)-- NT, #-ST ANDOFF INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. CONTHE INFORMATION HEREIN CONTTAINEDAINEDAL SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUMBER: — JB760427300 ax Z)iUMtK: UtKirnuN: Barry Smith 12.58 KW PV ARRAY Utbl(jN: David Borja Jimenez T 5 L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS comp V4 w Flashing —Insert 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM n PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH Southlake TX 76092 Moou�Es: THE SALE AND USE OF THE RESPECTIVE (37) Hanwho Q—CELLS # Q.Peak DUO BLK—G6+ 340 PAGE NAME: SHEET: REV: DATE: INVERTER: Delta Electronics # M8—TL—US [240V1 TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. 9728220934 STRUCTURAL VIEWS 4 d 12/17/2020 CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. Jobsite Specific Design Criteria Design Code ASCE-7-16 Ground Elevation Factor Ke 1 Ultimate Wind Speed V—Ult 150 Fig. 26.5-1B Exposure Category C Section 26.7 Ground Snow Load p9 5 Table 7.2-1 MP Specific Design Information MP Name MP1 MP2 MP3 MP4 MP8 Roofing Comp Shingle Comp Shingle Comp Shingle Comp Shingle Comp Shingle Standoff ZS Comp V4 w Flashing —Insert ZS Comp V4 w Flashing —Insert ZS Comp V4 w Flashing —Insert ZS Comp V4 w Flashing —Insert ZS Comp V4 w Flashing —Insert Pitch 23 24 24 24 24 SL/RLL: PV 2.7 psf 2.7 psf 2.7 psf 2.7 psf 2.7 psf SL/RLL: Non—PV 19.0 psf 18.5 psf 18.5 psf 18.5 psf 18.5 psf Standoff Spacing and Layout MP Name MP1 MP2 MP3 MP4 MP8 Landscape X—Spacing 72" 72" 72" 72" 72" Landscape X—Cantilever 24" 24" 24" 24" 24" Landscape Y—Spacing 41" 41" 41" 41" 41" Landscape Y—Cantilever Portrait X—Spacing 24" 24" 24" 24" 24" Portrait X—Cantilever 14" 14" 14" 14" 14" Portrait Y—Spacing 69" 69" 69" 69" 69" Portrait Y—Cantilever — — — — — Layout Staggered Staggered Staggered Staggered Staggered X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters. JOB NUMBER: J B-7604273 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (37) Hanwho Q—CELLS # Q.Peak DUO BLK—G6+ 340 INVERTER: Delta Electronics # M8—TL—US [240VI Barry Smith 1500 Bent Creek Dr Southlake, TX 76092 9728220934 12.58 KW PV ARRAY 81 KWH ENERGY STORAGE SYSTEM PAGE NAME: UPLIFT CALCULATIONS David Borja Jimenez SHEET: REV: DATE: 5 d 12/17/2020 T=SLn BOND (N) AWG #6 TO (N) GROUND ROD Panel Number: Inv 1: DC Ungrounded INV 1 (1) Delta Electronics # M8-TL-US [24OV] AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 116 893 925 Inverter; 7680W, 240V/208V, 97.5X Zigbee Underground Service Entrance E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER (N) 200A INTERNAL AC DISCONNECT ATIC RELAY AC DISCONNECT WIRING200A 3(E) X a7U 110A 20A 2P L1 L2 IN N N N --- ------- - - - - -- - EGCI I I 5 I 30Al2P ,I\Ll GEC 4 I � L2 W ENERGY N STORAGE ]SYSTEM ----- EGC - I I 30Al2P I I 6 I I � 4 L1 EGCI N L2 ENERGY LN W I L1 I STORAGE � I I _ EGC SYSTEM 30Al2P Z Z I 4 L1 TO 120/240V i W ENERGY __* 0--Lz SINGLE PHASE TO 2nd N STORAGE UTILITY SERVICE GATEWAY )nnA /)o Ikj EGCI SYSTEM Utility Meter (E) LOADS (E) 200A DISTRIBUTION PANEL THE VISIBLE LOCKABLE LABELED DISCONNECT IS LOCATED WITHIN 10 FT. OF ONCOR METER POI (1) Gro gd RoQ I \/�/ (3 )1092170-05-J /f, 5%8 x 8, Copper �J TESLA AC POWERWALL 2.0; Home Energy Storage,13.5KWH, Stackable, 5.8kVA /y Z (1)Eoton # DH224NRK Heavy Duty Disconnect, 200A, 24OVac, Fusible, NEMA 3R, 2P, 3W, for Class J fuses - (2) Bussmann # LPJ-200SP Class J fuse, 200A, 60OVac, must be installed in Heavy Duty disconnect Y (1)Tesla # 1232100-00-E Back-up Gateway 2.0 NA for AC PW 2.0 - (1) Eaton //�� CSR220ON tB ®o (1 ) AWG #10, THWN-2, Black (1) AWG #10, THWN-2, Red 200A ONLY; 2-Pole, 120V/24OV, 25kAIC, Bolt On (1) AWG #10, THWN-2, White - (1) CUTLER-HAMM R # BR230 Breaker; 30A�2P, 2 Spaces - (1)AWG #10, THWN-2, Green - (1) CUTLER-HAMM�R # BR220 Breaker; 20A 2P, 2 Spaces (1)C O (1) AWG #2, THWN-2, Black (1 ) AWG #2, THWN-2, Red - 2paces, Quadplex H�2312P2S (1 )AWG #2, THWN -2, WhiteBaP#0 - (1) Panelboard Accessory Kit for GW 2.0 NA 200A, 6sp/12cir, 120/24OV, 1PH (3)AWG #2/0, THWN-2, Black (1) CUTLER -HAMMER #DS16FK ©L-L (1)AWG #6, THWN-2, Green I Class R Fuse Kit -(2)FERRAZ SHAWMUT # TR110R (1 ) Copduit 2 PVC; Schedule 80 Fuse; 110A, 250V, Class RK5 - (1)CUTLER -HAMMER . # DG20ONK Ground/Neutral It; 200A General, Heavy Duty (DG, DH), NEMA 1, 3R O (3) AWG #2/0, THWN-2, Black (1) AWG #6, THWN-2, Green - (1 ) CUTLER -HAMMER ,# DG224NRK L-L IL�-LL (1) Copduit Disconnect; 200A, 240Vac, Fusible, NEMA 3R 2 PVC; Schedule 80 - ( 1 ) Conduit Kit; 1" EMT - (1) AWG #6, THWN-2, Green Inverter 1 IND Delta Electronics M8-TL-US [240V] 240V _ _ DC+ N GND DC - DC+ DC- ___ DC+ DC- EGC - (18) Hanwha Q-CELLS # Q.Peak DUO BLK-G6+ 340 PV Module; 34OW, 318 PTC, 4OMM, Black Fr, MC4, ZEP, 1000V Voc: 40.66 Vpmax: 33.94 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER L (1 ) Conduit Kit; 3/4" EMT r i MP 3/8: 1x12 i MP 1� 1x6 - GD Please see MCI wiring detail page for more information PV (6)DMCI # GP100010110 MCI Rapid Shutdown, 600V, 12A, NEMA 4X, MC4, Zep Bracket O1 (2) AWG #10, PV Wire, 60OV, Black Voc* = 532.71 VDC Isc = 10.52 ADC (1) AWG #10, THHN/THWN-2, Green EGC Vmp = 407.28 VDC Imp= 10.02 ADC (1) AWG #8, THWN-2, Black (1 ) Conduit Kit; 3/4" EMT (1) AWG #8, THWN-2, Red (2) AWG #10, PV Wire, 60OV, Block Voc* = 266.36 VDC Isc = 10.52 ADC II�LL(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC O c�� (1 )AWG #10, THHN/THWN-2, Green EGC Vmp=203.64VDC Imp=10.02 ADC CON -THE INFORMATION HEREIN CONTTAINEDAINED AL SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUMBER: J B- 7 6 0 4 2 7 3 00 CUSTOMER: DESCRIPTION: Barry Smith 12.58 KW PV ARRAY DESIGN: David Borja Jimenez T I 5 L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN zS comp V4 w Flashing -Insert 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM = n PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH S o u t h l a k e TX 76092 MODULES: THE SALE AND USE OF THE RESPECTIVE (37) Hanwha Q-CELLS # Q.Peak DUO BLK-G6+ 340 PAGE NAME: SHEET: REV: DATE: INVERTER: Delta Electronics M8-TL-US 240V TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION of TESLA INC. 9728220934 THREE LINE DIAGRAM 6 d 12/17/2020 GROUND SPECS MAIN PANEL SPEC BOND (N) AWG #6 TO (N) GROUND ROD Panel Number: AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:116 893 925 Underground Service Entrance TO MAIN AC DISCONNECT J 200A AUTOMATIC RELAY U GENERAL NOTES INVERTER Inv 2: DC Ungrounded INV 2 (1) Delta Electronics # M8-TL-US [24OV] Inverter; 768OW, 240V/208V, 97.57, Zigbee AC DISCONNECT (N) 200A INTERNAL J 110A "i. Ll \ L2 N N - EGCI GND _ ----------------- 30Al2P 14 I GEC 13 L1 I L2 S ENERGY N STORAGE 30Al2P EGC SYSTEM L1 Lz S ENERGY EGC.I N L2 L1 I N STORAGE _ _ EGC SYSTEM 30Al2P HH i 13 L1 � Lz S ENERGY N STORAGE 200A 2P �-------- Ecc SYSTEM - �• THE VISIBLE LOCKABLE LABELED DISCONNECT IS LOCATED (E) LOADS WITHIN 10 FT. OF ONCOR METER (E) 200A DISTRIBUTION PANEL POI (1 )05/8' Ld xR8, Copper TESLh1AC2POWERWALL 2.0; Home Energy Storage,13.5KWH, Stackable, 5.8kVA AC V (1 ) Eaton # DH224NRK HHeavy Duty Disconnect, 200A, 24OVac, Fusible, NEMA 3R, 2P, 3W, for Class J fuses -(2)Bussmann # LPJ-200SP Class J fuse, 200A, 60OVac, must be installed in Heavy Duty disconnect (1)TeI 1232100-00-E U s o # Back-up Gateway 2.0 NA for AC PW 2.0 (1 ) AWG #10, THWN-2, Black - )Eaton CSR220ON o (1 ) AWG #10, THWN-2, Red 200A B ONLY; 2-Pole, 120V/24OV, 25kAIC, Bolt On (1 AWG #10, THWN-2, White - (1) CBreaker;H 30AE/2P, 2 Spaces - (1) AWG #10, THWN-2, Green - (1) CUTLER -HAMMER # BR220 Breaker; 20A/2P, 2 Spaces ® (1) AWG #2, THWN-2, Black (1) AWG #2, THWN-2, Red - (1)CUTLER-HAMMER # BQC 30230 Breaker; 30A/2P-30A72P, 2 Spaces, Quadplex L-L (1)AWG #2, THWN-2, White - (1) Panelboard Accessory Kit for GW 2.0 NA 200A, 6sp/12cir, 120/24OV, 1PH (1)CClassRRHFuseEKit#DS16FK (3)AWG #2/0, THWN-2, Black 0 1 AWG , THWN-2, Green ( ) #6 (1) Copduit - (2)FERRAZ SHAWMUT # TR110R 2 PVC; Schedule 80 Fuse; 110A, 250V, Class RK5 - (1)CUTLER-tIAMMER DG20ONK Ground eutrol It; 200A General, Heavy Duty (DG, DH), NEMA 1, 3R (3) AWG #2/0, THWN-2, Black (1 ) AWG #6, THWN-2, Green - (1)CUTLER-HAMMER # DG224NRK L-L LL�-LL (1)Copduit Disconnect; 200A, 24OVac, Fusible, NEMA 3R 2 PVC; Schedule 80 - (1 ) Conduit Kit; 1" EMT - (1 ) AWG #6, THWN-2, Green Inverter 2 IND Delta Electronics M8-TL-US [240V1 240V - - DC+ N GND DC - DC+ ___ NDC EGC MODULE SPECS - (19) Hanwha Q-CELLS # Q.Peok DUO BLK-G6+ 340 PV Module; 34OW, 318 PTC, 40MM, Black Fr, MC4, ZEP, 1000V Voc: 40.66 Vpmax: 33.94 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER 32.0018 DC+ DC- MP 2: 1x7 EGC - - - - - - - - - - - - - tpj I DC+ I 10 DC- MP 1: 1x6 �- MP 2/4: 1x6 I EGC - (1 ) Conduit Kit; 3/4" EMT ®iF(1)AWG #8, THWN-2, Black (1 ) AWG #8, THWN-2, Red (1 )AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp-32 AAC GD Please see MCI wiring detail page for more information I (i) MULTI -CONTACT PV-AZB4 32.0018; Branch Socket; MC4 U-Joint Connector, Female - (1 ) MULTI -CONTACT PV-AZS4 \/ 32.00119; Branch Plug; MC4 U-Joint Connector, Male P v (6) DMCI Rapldl Shutdolwn, 600V, 12A, NEMA 4X, MC4, Zep Bracket O8 (2) AWG #10, PV Wire, 60OV, Black (1) AWG #10, THHN/THWN-2, Green Voc* = 310.75 VDC Isc = 10.52 ADC EGC Vmp = 237.58 VDC Imp= 10.02 ADC (1)Conduit Kit; 3/4" EMT O�(4)AWG Icsr #10, PV Wire, 60OV, Black (1) AWG #10, THHN/THWN-2, Green Voc*=266.36VDC Isc =10.52 ADC EGC Vmp = 203.64VDC Imp= 10.02 ADC II �-LL (1)Conduit Kit; 3/4" EMT ® (2) AWG #10, PV Wire, 60OV, Black Voc* = 266.36 VDC Isc = 21.04 ADC ( 1 ) AWG #10, Solid Bare Copper EGC Vmp = 203.64VDC Imp= 20.04 ADC (1)Conduit Kit; 3/4" EMT © (2) AWG #10, PV Wire, 60OV, Black Voc* = 310.75 VDC Isc = 10.52 ADC (1) AWG #10, Solid Bare Copper EGC Vmp = 237.58VDC Imp= 10.02 ADC CON -THE INFORMATION HEREIN CONTTAINEDAINED AL SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUMBER: J B- 7 6 0 4 2 7 3 00 CUSTOMER: DESCRIPTION: Barry Smith 12.58 KW PV ARRAY DESIGN: David Borja Jimenez 5 L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN zS comp v4 w Flashing -Insert 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM = n PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH S o u t h l a k e TX 76092 MODULES: THE SALE AND USE OF THE RESPECTIVE (37) Hanwha Q-CELLS # Q.Peak DUO BLK-G6+ 340 SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. Z PAGE NAME- 9728220934 THREE LINE DIAGRAM CONT. 7 d 12 17 2020 / / INVERTER: Delta Electronics M8-TL-US 24ov CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: J B-7604273 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (37) Hanwho Q—CELLS # Q.Pe INVERTER: Delta Electronics # M8—TL—US we] 12 DUO BLK—G6+ 340 Barry Smith 1500 Bent Creek Dr Southlake, TX 76092 9728220934 12.58 KW PV ARRAY 81 K WH ENERGY STORAGE SYSTEM PAGE NAME: PHOTOSHOP David Borja Jimenez SHEET: REV: DATE: 8 d 12/17/2020 T=SLn CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 1500 Bent Creek Dr -v ENERGY UTILITY STORAGE SERVICE SYSTEMx3 POO ENERGY STORAGE AC SYSTEM0 DISCONNECTx2 INVERTER AND AC DC DISCONNECT DISCONNECTx2 INVERTER AND ______________ DC DISCONNECT SOLAR PHOTOVOLTAIC ARRAY(S) PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V ]B-7604273-00 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: J B-7604273 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (37) Hanwho Q—CELLS # Q.Peak DUO BLK—G6+ 340 INVERTER: Delta Electronics # MB—TL—US [240VI Barry Smith 1500 Bent Creek Dr Southlake, TX 76092 9728220934 12.58 KW PV ARRAY 81 KWH ENERGY STORAGE SYSTEM PAGE NAME: SITE PLAN PLACARD David Borja Jimenez SHEET: REV: DATE: 9 d 12/17/2020 T=SLn Label Location: (BLC) Per Code: NEC 408.4 Label Location: (BLC) Per Code: NEC 220 Label Location: (MP) Per Code: NEC 312.8.A(3) Label Location: (MP) Per Code: NEC 705.12(B)(3) Label Location: (MP) Per Code: Label Location: (MP) Per Code: Label Location: (MP) Per Code: Label Location: (MP) Per Code: NOMINAL ESS VOLTAGE 120W MAX AVAILABLE SHORT- CIRCUIT FROM ESS- 32A ARC FAULT CLEARING TIME DATE CALCULATION: FROM OF ES& 67ms Label Location: (MP) Per Code: NEC 705.12(B)(3) Label Location: (MP) Per Code: NEC 705.12.B.2.3.c Label Location: (MP) Per Code: Per 706.7(D) label to be marked in field (AC): AC Disconnect (BLC): Backup Load Center (MP): Main Panel Label Set POWERWALL Tesla Powerwall is a fully -integrated AC battery system for residential or light commercial use. Its rechargeable lithium -ion battery pack provides energy storage for solar self -consumption, time -based control, and backup. Powerwall's electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120/240 V Feed -In Type Split Phase Grid Frequency 60 Hz Total Energy' 14 kWh Usable Energy' 13.5 kWh Real Power, max continuous2 5 kW (charge and discharge) Real Power, peak (10s, off-grid/backup)2 7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10s, off-grid/backup) 7.2 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device Imbalance for Split -Phase Loads 30 A 100% Power Factor Output Range +/- 1.0 adjustable Power Factor Range (full -rated power) +/- 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency',; 90% Warranty 10 years 'Values provided for 250C (770F), 3.3 kW charge/discharge power ,In Backup mode, grid charge power is limited to 3.3 kW. 'AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) w MECHANICAL SPECIFICATIONS Dimensions' 1150 mm x 753 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight' 114 kg (251.3 Ibs) Mounting options Floor or wall mount Dimensions and weight differ slightly if manufactured before March 2019. Contact Tesla for additional information. 753 mm 147 mm (29.6 in) (5.75 in) ENVIRONMENTAL SPECIFICATIONS TYPICAL SYSTEM LAYOUTS WHOLE HOME BACKUP Optional', \ I_ Solar Solar inverter -------------------------- Powerwall PARTIAL HOME BACKUP Optional 1150 mm I i (45.3 in) i Solar Operating Temperature -200C to 500C (-4°F to 122°F) Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH) Up to 100%, condensing Storage Conditions -200C to 300C (-4°F to 86°F) Up to 95% RE, non -condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C (86°F) 9- 10-1 T Main panel Backup Gateway Utility meter Grid including I service disconnect Whole home backup I o 0 Solar inverter ------------------- Sub panel T 5 5 L n Powerwall Backup loads o � O Backup Gateway Main panel Utility meter Grid O Home loads T = 5 L Fi TESLA.COM/ENERGY T = 5 L NA - BACKUP - 2019-06-11 TESLA.COWENERGY AhELTA Solar Inverter for North America Single Phase Solar Inverter for North America M4-TL-US I M5-TL-US I M6-TL-US I M8-TL-US I M10-TL-US I M10-4-TL-US Key Features: • Smart inverter with BLE, optional WiFi, Ether communication • Optional revenue grade meter (compliant wit • Support bi-directional cloud communication • Support remote diagnosis and OTA • Type 4 protection • Built-in AFCI & Rapid shutdown controller • CEC efficiency 97.5% • UL 1741 SA, HECO compliant • CA Rule 21 Phase 1 & 2 & 3 compliant AhELTA Solar Inverter for North America Model M4-TL-US I M5-TL-US I M6-TL-US I M8-TL-US I M10-TL-US I M10-4-TL-US INPUT (DC) Max. system voltage 600 V Nominal voltage 380 V Max. operating voltage 540 V Operating MPPT voltage 50 V to 480 V range Max. input current per 12 A 12 A 12 A 12 A 20 A 10 A MPPT Max. short circuit current per 15 A 15 A 15 A 15 A 30 A 15 A MPPT Max. DC/AC ratio 1.3 DC disconnect Integrated MPP tracker 2 2 3 3 2 4 Input strings available 2-2 2-2 2-2-2 2-2-2 2-2 2-2-2-2 OUTPUT (AC) Nominal output power 3840 W 4800 W 5760 W 7680 W 9600 W 9600 W 240Vac Max. output power 4000 W 5000 W 6000 W 8000 W 10000 W 10000 W 240Vac Nominal output power 3328 W 4160 W 4992 W 6656 W 8320 W 8320 W 208Vac Max. output power 3648 W 4560 W 5472 W 7296 W 9120 W 9120 W 208Vac AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Max. continuous current 16 A 20 A 24 A 32 A 40 A 40 A Nominal operating 60 Hz frequency Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Night consumption < 1.5 W 1) THD @ nominal power < 3 % Power factor @ nominal > 0.99 power Adjustable power factor 0.851 to 0.85c GENERAL SPECIFICATION Max. efficiency 1 98% CEC efficiency 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 9T5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V Operating temperature range -22 T to 149 T (-30 °C to 65 °C) with derating above 113 T (45 °C) Storage temperature range -40 T to 185 T (40 °C to 85 °C) Humidity 0% to 95% Max. operating altitude 9,843 ft (3,000 m) Acoustic noise < 45 dB(A) @ 3 ft (1 m) Rev 14 - 02/2020 @ Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. AhELTA Solar Inverter for North America Model MECHANICAL DOE Dimensions (W x H x D) M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US 16.7 x 23.2 x 5.9 in (425 x 590 x 150 mm) Display LED indicators Weight 2) 41.9lbs (19.0 kg) 41.9lbs (19.0 kg) 44.3 Ibs (20.1 kg) 45.2 Ibs (20.5 kg) 47.6 Ibs (21.6 kg) 47.6 Ibs (21.6 kg) Cooling Natural convection Natural convection with internal fan DC connection Spring contact type AC connection Spring contact type Rapid Shutdown Initiation Method Loss of AC or DC Disconnect Communication interface BLE, optional WiFi, Ethernet, 3G / 4G cellular communication Enclosure material I Die-casting aluminum Enclosure protection rating Type 4 Safety UL 1741, CSA-C22.2 No. 107.1-01 Software approval UL 1998 Ground fault protection UL 1741 CRD Anti-islanding protection IEEE 1547, IEEE 1547.1 EMC FCC part 15 Class B AFCI UL 1699B (Type 1), NEC 2017 Article 690.11 Rapid shutdown protection NEC 2017 690.12 3) Integrated meter ANSI C12.20, Class 0.5 Grid support regulation UL 1741 SA, California Rule 21 phase 1 & 2 & 3, HECO Compliant WARRANTY Standard warranty I 10 years Without consumption of communication card Without weight of revenue grade meter Compliant with Tigo rapid shutdown system or APS rapid shutdown system C us Delta Electronics (Americas), Ltd. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: Inverter.Sales@deltaww.com Support Email: Inverter.Support@deltaww.com Sales Hotline: +1-877-440-5851 or +1 -626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): -626-369-8019 ` AELT�1 Monday to Fridayayfrom Gam to 6pm PST (apart from Holidays) www.Delta-Americas.com Rev 14 - 02/2020 @ Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Ah E LTA Residential Energy Storage Solution for North America Accessory: MCI (Middle Circuit Interrupter) Features: • Automatic function test upon startup, ensure safety • Enclosure protection Type 4 • Meet 2017 NEC Article 690.12 Rapid Shutdown • No installation needed for every PV Module, make better cost performance for PV system • With PLC, no additional cable needed Delta part number GPI00010110 GPI00010114 Maximum system voltage 600 Vdc Rated input operating voltage 6 Vdc to 80 Vdc Number of input circuit 1 Startup voltage 22 V Rated input current Rated output current 12 A 12 A Control signal method Dimensions (W x H x D) PLC signal 4.6 x 6.5 x 3.0 in (117 x 165 x 76.5 mm) 3.8x6.5x1.1 in (97.3 x 165 x 27.3 mm) (without cable) (without cable) Weight 2.0 Ibs (0.9 kg) 1.4 Ibs (0.64 kg) Bracket Groove adapter bracket Without Cooling Natural convection DC input / output connectors MC4 PV connector Cable length with connector Input : 5.9 in (150 mm) Output: 47.2 in(1200 mm) Input: 5.9 in (150 mm) Output : 12 in (305 mm) Enclosure material Plastic Operating temperature -40 T to 185 T (-40 °C to 85 °C) Storage temperature -40 °F to 185 °F (-40 °C to 85 °C) Humidity 0% to 95% Maximum operating altitude 9,843 ft (3,000 m) above sea level Self power consumption <3.0 W Warranty 10 years Enclosure protection rating Pill Type 4 / IP67 Safety UL 1741, CSA C22.2 No. 330-17 Rapid shutdown NEC 2017 Article 690.12 EMC FCC Part 15 Class B Rev 05 - 09/2019 © Copyright 2018 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. POWERWALL Backup Gateway 2 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self -consumption, time -based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120/240V Feed -In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA' Overcurrent Protection Device 100-200A: Service Entrance Rated' Overvoltage Category Category IV AC Meter Revenue accurate (+/- 0.2 %) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self -consumption, time -based control, backup, and off -grid Backup Transition Automatic disconnect for seamless backup Modularity Optional Internal Panelboard Supports up to 10 AC -coupled Powerwalls 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2: cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION Certifications UL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi -flush mount 6 149 ENVIRONMENTAL SPECIFICATIONS Operating Temperature -200C to 500C (-4°F to 122°F) Operating Humidity (RH) Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R T = S L n NA 2020-OS-23 TESLA.CCM/ENERGY powered by r DUO billO. ' CELLS Qpp11Pi . . Product and Performance 144 Warranty c�MP P�\w QCELLS Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with �J excellent low -light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology', ` Hot -Spot Protect and Traceable Quality Ti ZEP COMPATIBLET11 FRAME DESIGN 7 High-tech black Zep Compatiblefm frame, for improved aesthetics, easy installation and increased safety. �g A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year \ll linear performance warrantyz. STATE OF THE ART MODULE TECHNOLOGY / Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168h) 2 See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays on commercial and o°O industrial buildings MECHANICAL SPECIFICATION Format 68.5 x 40.6 x 1.571n (including frame) (1740 x 1030 x 40 mm) 56 mm) Weight 47.4lbs(21.5kg) Front Cover 0.13 in (3.2mm) thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 x 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71in (53-101 x 32-60 x 15-18mm, Protection class IP67, with bypass diodes Cable 4mm2Solar cable;(+)>-43.3in(1100mm,(-)>-43.3in(1100mm) Connector Staubli MC4; IP68 I 68.5"(1740mm) 3Ja" (960 mm) 15]'lao - 6x Grwnaing P°ims°0.16"lamm7 - °�4� Fmme 7'01 38.6" 19- L�J 3�0p ��II - fix Dr.m•9a Wen�ng 4x Gem ,g poime(DETAIL A) 0.14"x3.1"13.emmxe1m IL mml D-LA 0.4721p2m H L063'(27-) -r�-I0.35a (9mm) ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345. MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE+5 W -OW) Power at MPP1 PMPP [w] 330 335 340 345 Short Circuit Current' Isc [A] 10.41 10.47 10.52 10.58 E E Open Circuit Voltage' Vs. IV] 40.15 40.41 40.66 40.92 5 Current at MPP IMPP [A] 9.91 9.97 10.02 10.07 Voltage at MPP VM,P IV] 33.29 33.62 33.94 34.25 Efficiency' r) [%] >-18.4 >-18.7 >>>19.0 >-19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP PMPP [w] 247.0 250.7 254.5 258.2 E Short Circuit Current Isc [A] 8.39 8.43 8.48 8.52 E Open Circuit Voltage c Von IV] 37.86 38.10 38.34 38.59 i Current at MPP IMPP [A] 7.80 7.84 7.89 7.93 Voltage at MPP VMPP IV] 31.66 31.97 32.27 32.57 Weasurement tolerances PMPP±3%; Isd Voc+-5%at STC: 1000 W/m2, 25±2°C, AM 1.5 according to IEC 60904-3. 2800 W/m?, NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE u; 6 LLo >z w ,2 0 zz o 0 2 ou 7 At least 98 %of nominal power during u0 first year. Thereafter max. 0.54% W degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 %of nominal power up to 25 years. 5 ao-r----r----r----r----j I I I I All data within measurement toleranc- p es. Full warranties in accordance with 80 200 400 eoo eoo moo the warranty terms of the Q CELLS IRRADIANCE lw/m+] sales organization of your respective ° ,6 2g country. 's­,zo1°, YEARS Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2) TEMPERATURE COEFFICIENTS Temperature Coefficient of 13D a [%/K] +0.04 Temperature Coefficient of V.D ji [%/ K] -0.27 Temperature Coefficient of l y [%/K] -0.36 Normal Module Operating Temperature NMOT [°F] 109±5.4 (43±3°C) PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage V5 [V] 1000 (IEC)/1000 (UL) Protection Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating based on Al UL 1703 C (IEC)/TYPE 2 (UL) Max. Design Load, Push/Pull(UL)3 [Ibs/ft2] 50(2400Pa)/50(2400Pa) Permitted Module Temperature -40OFupto+185°F Max. Test Load, Push/Pull(UL)2 [Ibs/ft2] 75(3600Pa)/75(3600Pa) on Continuous Duty (-40°Cupto+85°C) 'See Installation Manual QUALIFICATIONS AND CERTIFICATES UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016, Application Class 11, U.S. Patent No. 9,893,215 (solar cells) e pVE [ cSP�soj A4 Note: Installation instructions must be followed. Seethe installation and operating manual or contact our technical service department for further information on approved installation and use of this product. 0CELLS Hanwha Q CELLS Center Drive, America , Inc. Engineered in Germany 4,07 Center Drive, Suite 1400,Irvine, CA 92618, USA ITEL+1949748599filEMAIL inquiry@us.q-cells.coml WEB www.q-cells.us GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.6.2.1) • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) RETROFIT PV MODULES • MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH - MCI INPUT = 1 MODULE - NUMBER OF MODULES BETWEEN MCI UNITS = 0-3 - MAXIMUM NUMBER OF MODULES PER MCI UNIT = 4 - MINIMUM NUMBER MCI UNITS = MODULE COUNT/4 PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR MORE INFORMATION T=SLn J—BOX Cl J—BOX J—BOX J—BOX J—BOX MCI J—BOX 1 (2 ) AWG, PV Wire, 60OV, Black DC ^SOiafclty ®pSolar Next -Level PV Mounting Technology ' SOiafclty ®pSolar Next -Level PV Mounting Technology ZS Comp for composition shingle roofs Components G Mounting Block Array Skint Part No. 850-1633 Part No. 850-1608 or 500-0113 Listed to UL 2703 Listed to UL 2703 Interlock Part No. 850-1388 or 850-1613 Listed to UL 2703 r gym° Flashing Insert Grip Ground Zep V2 Part No. 850-1628 Part No. 850-1606 or 850-1421 Part No. 850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 Q��MPAT�b Description PV mounting solution for composition shingle roofs FA Works with all Zep Compatible Modules °n1va��e Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Captured Washer Lag End Cap U� LISTED Part No. 850-1631-001 Part No. Specifications 850-1631-002 (L) 850-1586 or 850-1460 850-1631-003 (R) 850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703�s, • Engineered for spans up to 72" and cantilevers up to 24"0 • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No. 850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zap Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839.001 Rev 0 Date last exported: April 29, 2016 11:22 AM V# DC Wire Clip Part No. 850-1509 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying thesuitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM ROOFING SYSTEM SPECIFICATIONS DESCRIPTION SPECIFICATIONS PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules Auto bonding UL-listed hardware creates structural and electrical bond ZS Span has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Q�pMP4Tj6 ti UL LISTED r�ACOMPA���v Designed for pitched roofs Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 Engineered for compliance with ASCE 7-16 wind load requirements ZS Comp grounding products are UL listed to UL 2703 and UL 467 ZS Comp bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices GROUND ZEP V2 . LEVELING FOOT Listed to UL 2703 and UL 467 Listed to UL 2703 Part #850-1511 Part #850-1397 I — MOUNTING BLOCK . FLASHING INSERT Listed to UL 2703 Listed to UL 2703 and UL 2582 for Wind Driven Rain Part #850-1633 Part #850-1628 O:0 � 0 . CAPTURED WASHER LAG Part #850-1631-002 and #850-1631-004 END CAP Part #850-1586 or 850-1460 (Left) Part #850-1588 or 850-1467 (Right) <I INTERLOCK Listed to UL 2703 Part #850-1613 or #850-1388 Listed to UL 2703 Part #850-1608 or #500-0113 SKIRT GRIP DC WIRE CLIP Listed to UL 2703 Listed to UL 1565 Part #850-1606 or #850-1421 Part #850-1509 L n ZS COMP DATASHEET 2 T = 5 L n ZS COMP DATASHEET 3 PVRSA Model: ZS Rapid Shutdown Array (Applicable to ZS Comp, ZS Span, ZS Ramp, and ZS Seam) Category QIJR, Report Date: 2020-05-01 TABLE OF ESSENTIAL ELEMENTS Firmware Versions Function Manufacturer Model No. and Checksums Certification Standard PVRSE Mid Circuit Delta Electronics GPI000101102 2.1.6 UL 1741 PVRSE Interrupter (MCI) Sys: 2.2.11 Inverter Delta Electronics M4, M5, M6, M8, M10 Pwr: 1.4.9 UL 1741 Safety: 1.4.3 Q.PEAK DUO BLK-G5/SC315 PV Module Hanwha Q-CELLS N/A UL 1703 Q.PEAK DUO BLK-G5/SC320 ZEP 850-1613-001 Interlock Tesla ZEP 850-1388-001 N/A UL 2703 ZEP 850-1281-001 ZEP 850-1511-001 UL 467 Ground Zep Tesla N/A ZEP 850-1172-002 UL 2703 ZEP 850-1509-001 DC Wire Clip Tesla ZEP 850-1448-001 N/A UL 1565 Homerun Wire Clip Tesla ZEP 850-1510-001 N/A UL 1565 PVRSA Initiator' Non -Specific N/A N/A N/A (See installation req. below) 1 Dedicated PV system AC circuit breaker or AC disconnect switch, labeled per NEC 690.12 requirements. 2 Applies to variations of this part number, e.g. suffixes. Note: PVRSA installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVRSE ratings in order to achieve PVRSA shock hazard reduction requirements. PVRSA INSTALLATION REQUIREMENTS Max System Voltage 600 VDC Max Array Internal Voltage After Actuation 165 VDC (cold weather open circuit) Max Series -Connected Panels between MCI Output Connections: 3 Max Series -Connected Panels Connected to MCI Inputs: 1 OTHER INSTALLATION INSTRUCTIONS 1. MCIs shall be mounted to module frames with Delta -supplied brackets. 2. An MCI must be connected to one end of each series string or sub -array string. 3. Verification that MCIs are installed with 3 or fewer modules between MCI output connections shall be documented for inspection, by voltage measurement logs and/or as -built string layout diagrams. 4. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVRSA initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as -built system drawings. ® Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its Certification and Follow -Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY", the geographic identifier(s), and a file number.